Labtech 20121120_SS HIRE Bro c 2 Copy
-
Upload
carlos-perea -
Category
Documents
-
view
220 -
download
0
description
Transcript of Labtech 20121120_SS HIRE Bro c 2 Copy
-
The groups broad capability includes but is not limited to the design and construction of:
Specialist Services was established in 1982 and has developed a global engineering and manufacturing capability in multiple locations supporting a broad range of products, services and solutions in the oil and gas, utility and renewables sectors.
Truly solution orientated, we are able to provide a number of cost effective solutions that fulfil the most challenging environmental and international compliance requirements. We have extensive experience in the onshore and offshore energy sector including in-house engineering, fabrication, construction, installation and service disciplines.
SPECIALIST SERVICES GROUP
Offshore living quarters Technical buildings and control modules A60 modular buildings Drilling, well testing and production equipment Process and packaged equipment solutions Certified architectural products (Fire rated doors, windows, blast walls, wet units etc) Specialist Services HIRE division supporting one of the worlds largest A60 certified
rental fleets from multiple international centres
Our core strength comes from the diverse backgrounds and experience of our staff. We are a highly resourced, responsive global solutions company that delivers innovative products with international service and support through our international offices and fabrication facilities.
-
Wh
y h
IRE
FRO
M S
PE
CIA
LIST
SE
RV
ICE
S?
Specialist Services is a global supplier of modular buildings and packaging solutions for people and equipment in the oil and gas and utility industries.
Established in 1982, we have developed an international capability in the provision of design, engineering, manufacture, installation and support across our broad product and service options.
-
SPECIALIST SERVICES HIRE DIVISION
-
Wh
y h
IRE
FRO
M S
PE
CIA
LIST
SE
RV
ICE
S?
Specialist Services hIRE division is a leading hIRE solutions provider for the onshore and offshore energy industry with one of the worlds largest A60 HIRE fleets available from our global hIRE centres located in Abu Dhabi, Dubai, Aberdeen and Singapore. All units manufactured by Specialist Services are built to the highest industry standards and can be delivered and supported worldwide to serve your project needs.
Why hIRE FROM SPECIALIST SERVICES?
SPECIALIST SERVICES hIRE CENTRES
Reduces client CAPEX Immediate availability and deployment CSC and ISO certifications ensure ease of transport and shipping at a lower cost All units are designed to be easily assembled on site ensuring safe and speedy deployment Minimise the cost and time impact of breakdowns Industry leading Fleet Management System offers maintenance and service support globally
24/7/365 HIRE service to the energy industry Wide range of offshore and onshore A60 units for HIRE available from stock Manufactured to the latest industry standards DNV, ATEX, SOLAS, NORSOK, ABS, etc Full service, maintenance and spare parts available to all worldwide locations
We offer our HIRE clients the following services through our HIRE Centres:
-
Dimensions (mm) Tare Weight (kg)
6058 (L) X 2438 (W) X 2591 (H) 7100
Product General Description Features & Benefits
Electrical Data
Dimensions & Weight
Global Compliance
20 A60 SOLAS 4 or 6 man Accommodation for offshore platforms, barges and vessels
Linkable accommodation units with customised design built in our own facilities
Design temperature can be provided or constructed to the following range -50C to +50C
4 man unit with GRP wet unit for offshore applications Safe area electrics and HVAC system for all units Non-combustible B15 wall panels ensuring high thermal resistance
and superior noise reduction
2 independent A/C units provide redundancy Fresh air supply provided in accommodation and toilet area via
ducting system
2 entrance doors provide flexibility when placing the unit offshore Internal visual and audible alarms with external junction box
connection for easy rig safety system tie-in
Smoke detector, sprinkler head and piping provided for easy rig tie-in
Single or 2 phase at 220 VAC, 50/60 Hz Unit is provided with 30m braided ships cable
CSC A60 SOLAS CE Marked DNV 2.7-1 or BS EN12079 ISO
ACCOMMODATION MODULES
4 man accommodation unit
-
AC
CO
MM
OD
ATIO
N M
OD
ULE
S
-
Product General Description Features & Benefits
Global Compliance
A60 SOLAS linkable accommodation units with customised design Can be easily assembled on the site of offshore platforms, barges
and vessels
Design temperature can be provided or constructed to the following range -50C to +50C
Designed to offer a flexible lay down solution Easy plug & play hook-up SOLAS A60 rated conforms to the latest FTP codes (H-ratings optional) Fire detection fitted Each room fitted with twin split-air conditioning system, a GRP wet unit c/w shower,
WC and basin
Smoke detector, sprinkler head and piping provided for easy rig tie-in
Electrical Data
Dimensions & Weight
Single or 2 phase at 220 VAC, 50/60 Hz Unit is provided with 30m braided ships cable
CSC A60 SOLAS CE Marked DNV 2.7-1 or BS EN12079 ISO
Dimensions (mm) Tare Weight (kg)
6058 (L) X 4876 (W) X 2591 (H) 13,830
LINKABLE ACCOMMODATION MODULES
2 linkable units general arrangement
-
AC
CO
MM
OD
ATIO
N M
OD
ULE
S
8 man module (2x4 man back to back)
-
* 30 Unit and 10 Unit also available
Product General Description
Electrical Data
Dimensions & Weight
Global Compliance
A60 Zone 1 & 2 office units available in 30 20 16 14 12 10 Design temperature can be provided or constructed to the
following range -50C to +50C
Zone 1 electrics, fire & gas and HVAC system
3 phase electrical systems from 380 VAC through to 690 VAC at 50/60 Hz
Supplied with 30m of power cable manufactured to IEC 332-2/IEC 92-350
Intrinsically safe (I.S.) earth connections are available on the earth bar A 5kVA Noise Suppressor Transformer provided for electrical sockets
CSC ( for 20 unit only) A60 SOLAS CE Marked DNV 2.7-1 or BS EN12079 DNV 2.7-2 ISO ATEX
Dimensions (mm) Tare Weight (kg)
20 Unit 6058 (L) X 2438 (W) X 2591 (H) 7800
16 Unit 4875 (L) X 2438 (W) X 2591 (H) 6400
14 Unit 4260 (L) X 2438 (W) X 2591 (H) 6000
12 Unit 3670 (L) X 2438 (W) X 2591 (H) 5500
ENGINEERING MODULES OFFICE
Generation III office module
-
EN
GIN
EE
RIN
G M
OD
ULE
S
Features & Benefits
Detection and alarm system with Control Pressurisation, Fire and Gas detection (CPFG) panel with all ancillary items for use up to Zone 1. It includes H2S and HC gas detection, smoke detection, manual call point, pressurisation fan, loss of pressure and flow devices
2 split type AHU type A/C system developed by Specialist Services to condition incoming pressurised air (hot, humid and cold) up to Zone 1 use
Pneumatic fire dampers are provided with N2 bottle inside. Primary connection is rig air. Electric (24VDC) can be provided as an option
A60 window and A60 escape hatch (800mm x 800mm) are provided as per DNV 2.7-2 requirement
Sprinkler head and piping can easily tie in to rig sprinkler system Fitted with non-combustible B15 wall panels to ensure high thermal
resistance and superior noise reduction
Easy access for all serviceable equipment for swift maintenance CO2 fire extinguisher provided Non-porous top; stone epoxy desktop provided; easy to clean, stain
resistant and impermeable to most chemicals
Coving lights allow good aesthetics with required illumination levels
-
20 NORSOK office unit
Product General Description
Electrical Data
Global Compliance
20 NORSOK compliant unit Zone 1 Electrics, Fire & Gas and HVAC system Design temperature can be provided or constructed to the
following range -50C to +50C
3 phase electrical systems from 380 VAC through to 690 VAC at 50/60 Hz
Supplied with 30m of power cable manufactured to IEC 332-2/IEC 92-350
Intrinsically safe (I.S.) earth connections are available on the I.S. earth bar A 5kVA noise suppressor transformer provided for electrical sockets
CSC (for 20 unit only) A60 SOLAS CE Marked ATEX DNV 2.7-1 or BS EN12079 DNV 2.7-2 ISO NORSOK
Dimensions (mm) Tare Weight (kg)
20 Unit 6058 (L) X 2438 (W) X 2591 (H) 7800
16 Unit * 4875 (L) X 2438 (W) X 2591 (H) 6400
14 Unit * 4260 (L) X 2438 (W) X 2591 (H) 6000
12 Unit * 3670 (L) X 2438 (W) X 2591 (H) 5500
Dimensions & Weight
ENGINEERING MODULES NORSOK COMPLIANT OFFICE
* Optional
-
EN
GIN
EE
RIN
G M
OD
ULE
S
All features of A60 Zone 1 office units NORSOK compliant adjustable desk top and ceramic floor system A60 window and A60 escape hatch (800mm x 800mm) as per
NORSOK requirements
Features & Benefits
-
A60 Zone 1 & 2 laboratory unit available in 20 16 14 12 Design temperature can be provided or constructed to the
following range -50C to +50C
Zone 1 Electrics, Fire & Gas and HVAC system
Product General Description
Electrical Data
Global Compliance
3 phase electrical systems from 380 VAC through to 690 VAC at 50/60 Hz
Supplied with 30m of power cable manufactured to IEC 332-2/IEC 92-350
Intrinsically safe (I.S.) earth connections are available on the earth bar A 5kVA noise suppressor transformer provided for electrical sockets
CSC ( for 20 unit only) A60 SOLAS CE Marked ATEX DNV 2.7-1 or BS EN12079 DNV 2.7-2 ISO NORSOK
Dimensions (mm) Tare Weight (kg)
20 Unit 6058 (L) X 2438 (W) X 2591 (H) 7800
16 Unit 4875 (L) X 2438 (W) X 2591 (H) 6400
14 Unit 4260 (L) X 2438 (W) X 2591 (H) 6000
12 Unit 3670 (L) X 2438 (W) X 2591 (H) 5500
Dimensions & Weight
ENGINEERING MODULES LABORATORY
20 Laboratory unit
-
Available in ATEX Zone 1 & 2 and NORSOK A sink and / or a fume hood is provided Large sample preparation area to perform all sample related procedures
from washing and drying the sample to analysis
Storage for chemicals, trays, glassware and other sample related items
Geologist and operator work area supplied with electrical outlets, network connection ports and data display monitors
Features & Benefits
EN
GIN
EE
RIN
G M
OD
ULE
S
-
Product General Description
20 / 14 / 10 workshop with electrics suitable for Zone 1 operation Design temperature can be provided or constructed to the
following range -50C to +50C
Electrical Data
Global Compliance
Single phase at 220 VAC, 60 Hz Supplied with 30m of power cable manufactured to IEC 60332-3/IEC
92-350
DNV 2.7-1 or BS EN12079 ISO CE Marked ATEX ZONE 1 CSC ( for 20 unit only)
Dimensions (mm) Tare Weight (kg)
20 Unit 6058 (L) X 2438 (W) X 2591 (H) 8000
14 Unit 4267 (L) X 2438 (W) X 2591 (H) 5500
10 Unit 2991 (L) X 2438 (W) X 2591 (H) 3600
Dimensions & Weight
ENGINEERING MODULES WORKSHOP
Workshop unit
-
EN
GIN
EE
RIN
G M
OD
ULE
S
Container door for easy movement of tools and objects 20 workshop unit equipped with a 2 ton capacity manual hoist Overhead cabinets available in 20 units for storage purposes Steel workbench with a vice Storage rack and tool hangers in 14 and 10 units Access door in addition to the container door for flexible access Provision for installation of an ex-blower fan inside the unit for
fresh / cooler air
ATEX floodlight for external operation
Features & Benefits
-
20 A60 freezer / chiller unit for safe area operation Design temperature can be provided or constructed to the
following range -50C to +50C
Safe Area Electrics and HVAC system
Product General Description
Electrical Data
Global Compliance
Transformer provided to accommodate a range of incoming power supplies
Suitable for operation at 50/60 Hz Provided with 30m power cable
DNV 2.7-1 or BS EN12079 CSC A60 SOLAS ISO CE Marked
Dimensions (mm) Tare Weight (kg)
20 Unit 6058 (L) X 2438 (W) X 2591 (H) 7000
Dimensions & Weight
FREEZER /CHILLER MODULES
Freezer unit
-
SE
RV
ICE
SU
PP
OR
T
Separate temperature controls for chiller and freezer units Electronic control panel to enable adjustment of internal temperature
and control of cooling plant functions
Flashing beacon in operation when the unit is powered Data logger to record optional temperatures from dispatch to delivery Easy to clean stainless steel interior ensures hygienic environment Inside door with heavy duty stainless steel hinges Stainless steel shelving provided in both chiller and freezer sections
for maximum storage
Features & Benefits
-
Fleet Management
Specialist Services Fleet Management Solutions system stores critical product specific information such as asset numbers, manuals, drawings and certification and generates automated emails to alert users at the client end when certifications are due to expire and when routine service visits are due. The Fleet Management software will track and identify failures with units through the unique fault code analysis system and will alert customers of possible future failures and preventative measures before they occur.
Customers have the option to utilise Specialist Services service and maintenance team to perform these routine inspections, services and recertification. These measures are intended to free end users from the burden of servicing and re-certification management.
All Specialist Services service team members are experts in the field and qualified to work in accordance with the latest industry standards such as:
COMPEX Globally recognised qualification for installation, maintenance & inspection of ATEX & IECEx equipment
F-GAS Our service teams are F-GAS qualified and registered as an approved contractor with REFCOM
IICL IICL licenced CSC container and frame inspectors
Spare Parts
Guaranteed inventory support for our complete product range Client product specific kits Provision of upgrade equipment solution and upgrade installation support Refurbishment solutions for obsolete equipment Online spare parts ordering system
24/7/365 Global on call site service
Installation/commissioning Fault diagnosis and repairs Routine service testing and inspection Ex equipment inspection Upgrades and modification installation and support
24/7/365 MAINTENANCE SUPPORT SERVICE
-
SE
RV
ICE
SU
PP
OR
T
-
CONTACTS
Specialist ServicesPO Box 2752, DubaiUnited Arab EmiratesTel: +971 4 4579500Fax: +971 4 4579501Email: [email protected]
Asia Pacific HIRE CentreBlock 103, Tops Avenue 1, #01-04Loyang Offshore Supply BaseRepublic of SingaporeTel: +65 6214 9764
MENA HIRE Centre Abu DhabiPO Box 3917Abu DhabiUnited Arab EmiratesTel: +971 4 4579500
MENA HIRE Centre DubaiJebel Ali Industrial Area #2PO Box 2752 DubaiUnited Arab EmiratesTel: +971 4 4579500
Europe and Americas HIRE CentreLABTECH Services LimitedBlackness Road, AltensAberdeen, UKTel: +44 1224 337777
-
All Rights Reserved Specialist Services 2012