L96C5_spec

2
02-2011 t 1.877.708.1184 f 604.708.1185 www.mplighting.com 16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada Copyright © MP Lighting. All technical information in this document is subject to change. 6W Pendant L96C5 SPEC SHEET Application: Indoor pendant downlight illumination. Electrical: 6 x 1W LEDs powered by 300mA remote driver (not included). Input Current: 300mA Input Voltage: 24V DC Power Consumption: 6W Recommended Driver: TLDAV100W24V. 0~10V dimming with remote dimmable driver available (not included). Consult factory. Weight: 1.87lbs (0.846kg). Material: Anodized aluminum. Mounting: Mount to standard J-box (not included). Approval: Dry locations. Approved to US and Canadian standards by CSA. 40 CAUTION: LED DRIVER MUST BE USED AS THE POWER SUPPLY. USING A TRADITIONAL LOW VOLTAGE 12V TRANSFORMER WILL NOT WORK AND WILL DAMAGE LEDS. Type: Project: Modified: Quantity: Notes: C5 = Ø4-5/8” x 1-1/8” canopy Ø4-5/8” Ø117mm Ø3” Ø76mm 3-1/2” 89mm 1-1/8” 29mm 12-1/8” 308mm 6” 152mm stem 6-3/8” 162mm MA = matte clear anodized BA = black anodized CODE MOUNT COLOR BEAM CORD / STEM FINISH L96 C5 - 25 - S6 = 6” (152mm) stem SX = custom stem C72 = 72” (1829mm) cord CX = custom cord 25 = 25° beam W27S = 2700K, std CRI W30S = 3000K, std CRI W35S = 3500K, std CRI W41S = 4100K, std CRI W30H = 3000K, high CRI

description

http://www.mplighting.com/pdf/spec/L/L96C5_spec.pdf

Transcript of L96C5_spec

Page 1: L96C5_spec

02-2011

t 1.877.708.1184 f 604.708.1185 www.mplighting.com16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada Copyright © MP Lighting. All technical information in this document is subject to change.

6W Pendant

L96C5SPEC SHEET

Application: Indoor pendant downlight illumination.

Electrical: 6 x 1W LEDs powered by 300mA remote driver (not included).

Input Current: 300mA Input Voltage: 24V DC Power Consumption: 6W Recommended Driver: TLDAV100W24V. 0~10V dimming with remote dimmable driver available (not included). Consult factory.

Weight: 1.87lbs (0.846kg).

Material: Anodized aluminum.

Mounting: Mount to standard J-box (not included).

Approval: Dry locations. Approved to US and Canadian standards by CSA.

40

CAUTION: LED DRIVER MUST BE USED AS THE POWER SUPPLY. USINg A TRADITIONAL LOW VOLTAgE 12V TRANSfORMER WILL NOT WORK AND WILL DAMAgE LEDS.

Type:

Project:

Modified:

Quantity:

Notes:

C5 = Ø4-5/8” x 1-1/8” canopy

Ø4-5/8”Ø117mm

Ø3”Ø76mm

3-1/2”89mm

1-1/8”29mm

12-1/8”308mm

6”152mm

stem6-3/8”162mm

MA = matte clear anodizedBA = black anodized

Code Mount Color BeaM Cord / SteM FiniSh

L96 C5 - 25 -

S6 = 6” (152mm) stemSX = custom stem C72 = 72” (1829mm) cordCX = custom cord

25 = 25° beamW27S = 2700K, std CRIW30S = 3000K, std CRIW35S = 3500K, std CRIW41S = 4100K, std CRI W30H = 3000K, high CRI

Page 2: L96C5_spec

Copyright © MP Lighting. All technical information in this document is subject to change. 12-2010

t 1.877.708.1184 f 604.708.1185 www.mplighting.com16 West 4th Avenue, Vancouver BC V5Y 1G3, Canada

Photometric Data

Note: Various operating factors may cause differences between lab and field results. as specifications may change without notice, please refer to the led lamp index located in the “downloads” section of each product webpage for the most current information.

6W Pendant

L96C5SPEC SHEET

approx. 2200 cdmax.

180°

90°

45°-45°

-90°

9.0’

7.5’

6.0’

4.5’

3.0’

1.5’

3.3’

2.7’

2.2’

1.6’

1.1’

0.5’

3.3’

2.7’

2.2’

1.6’

1.1’

0.5’965.19

241.30

107.24

60.32

38.61

26.81

Center Beam FC Beam Width

0° Spread: 20.5°

90° Spread: 20.7°

Illuminance at a DistanceL9625°3000K Std510 lm

Polar Candela Distribution