L60AD4
Analog-digital converter module
Mitsubishi Electric Programmable Controller
Quickly calculate the flow amount!
Logging function
Point1Point1Point1Point1Point1Log data for up to 10,000 points!
Point2Point2Point2Point2
Input signal error detection extension functionThe detection method of the input signal error detection function can be extended. Use this function to detect the input signal error only in the lower limit or upper limit, or to execute the disconnection detection.
Input range extended mode functionThe input range can be extended. By combining this function with the input signal error detection function, simple disconnection detection can be executed.
Expand detection methods to match your needs!
New!
New!
Point4Point4Point4Point4
Flow amount integration functionThe flow amount integration function executes the integral processing of input (instantaneous flow amount) from a flow meter and easily calculates the flow amount in a certain period. By registering/outputting the calculated flow amount, system operation can be improved and man-hours for programming can be reduced.
New!
Point3Point3Point3Point3
Difference conversion functionThis function subtracts the difference conversion reference value from the scaling value (digital operation value) and stores the acquired value in the buffer memory.
Easily measure part thicknesses! New!
Point2
Point3
Point4
Logging cycleMinimum
Maximum
80μs3600s
The data of 10,000 points can be logged for each channel.Data is continuously collected at the set cycle and stored in the buffer memory.
Improve operability!
Improve maintainability of control systems!
![Page 2: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.](https://reader035.fdocuments.in/reader035/viewer/2022081406/5f0e72967e708231d43f4ade/html5/thumbnails/2.jpg)
Point1Point1Point1 Log data for up to 10,000 points!
Data is continuously collected at the set cycle and stored in the buffer memory.Data stored in the buffer memory can be used for debugging, and to periodically confirm data variations.The data can be exported to Excel® allowing time-series data to be confirmed easily.
Logging function New!
Record inspection details
and analyze with the log data
Inspection of
part appearance
When data for 10,000 points has been stored, the data is overwritten from the 1st point data.
Buffer memory
1st data
2nd data
3rd data
4th data
5th data
6th data
9999th data
10000th data
Collected data
Storage of collected data
Unusual data can be analyzed.…
Improve maintainability with new functions!
Logging data can be transferred to the CPU device memory while still logging.Logging and data transmission can be executed simultaneously so the next inspection can be started right away.
Extract data without stopping logging!
A digital value unusual?
Data are displayedand analyzed on Excel®.
Collecting logging datausing MX Sheet.
Start the logging facility
Trigger occurred
Stop logging
Store data tothe buffer memory
· A large amount of data can be logged at high speed.A maximum speed of 80 μs, 10,000 points per channel.
· Conditions for the level trigger can be set.
· Logging points after the trigger can be set.
1. Above 2. Below 3. Pass through
Logging cycleMinimum 80μs
Maximum 3600s
Collected dataDigital output value
Scaling value(Digital operation value)
Number of collection points10,000 points
(Stored in buffer memory for each channel)
1st to 1000th data
1001st to 2000th data
2001st to 3000th data
3001st to 4000th data
4001st to 5000th data
5001st to 6000th data
6001st to 7000th data
7001st to 8000th data
8001st to 9000th data
9001st to 10000th data
1st to 1000th dataLogging completed area
L60AD4 CPU device memory
Logging area
Transfer
Logging standby area
While logging the 1001st to 2000th data, the 1st to the 1000th data is transferred to the CPU device memory by the ladder program.By transferring the data for every 1000 points, data for more than 10000 points can be logged.
[Continuous logging example]
Log data for more than 10,000 points!
Features
Improve maintainability of control systems!
Improve operability!
Transfer data for more than 10,000 points to the CPU!
So convenient!
Data areanalyzed!Data are
analyzed!
1
![Page 3: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.](https://reader035.fdocuments.in/reader035/viewer/2022081406/5f0e72967e708231d43f4ade/html5/thumbnails/3.jpg)
2
USA
Braz
Germ
UK
Italy
Spain
Fran
Czec
Polan
Russ
Coun
11
L60A
Point1Point1
Point2
Point4
Point3
It's convenient!In the flow amount integration function, the integration cycle can be set in 1ms.
Point2Point2Point2 Expand detection methods to match your needs!
The input signal error detection function includes detect only upper limit, detect only lower limit, and detect disconnection.
Input signal error detection extension function
Point3Point3Point3 Easily measure part thicknesses!
This function subtracts the difference conversion reference value from the scaling value (digital operation value) and stores the acquired value in the buffer memory.
When difference conversion starts, this module outputs the A/D conversion value at the start point as the difference conversion reference value, and stores the value obtained by subtracting the difference conversion reference value from the A/D conversion value as the scaling value. After that, the increment or decrement from the difference conversion reference value is stored in the scaling value.
Difference conversion function
Point4Point4Point4 Quickly calculate and record flow amount!
This function performs the A/D conversion of analog input value (voltage or current) from a flow meter and others, and integrates the scaling value (digital operation value) by every integration cycle. In this function, integral processing is performed regarding the scaling value (digital operation value) as the instantaneous flow amount.
Flow amount integration function
New!
The input range 4 to 20mA and 1 to 5V input valid range can be expanded.
Input range extended mode function New!
New!
New!
Measuresinstantaneous flowamount of liquid,and outputs the analog value
Flow meter, Control valveIntegratesinstantaneous flow amount
Liquid
Power conditioner
Heater
Detect voltages and currents exceeding the setting value!
Perform A/D conversion at high resolution.
Measure flatness and variation!
Easily check for irregularities!
E
P
MELanal
![Page 4: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.](https://reader035.fdocuments.in/reader035/viewer/2022081406/5f0e72967e708231d43f4ade/html5/thumbnails/4.jpg)
Point1 Item Description
A/D conversion enable/disable function
Sets whether to enable or disable A/D conversion for each channel.Disabling the A/D conversion for unused channels reduces the conversion cycles.
A/D conversionmethod
Input signal error detection extension function
The detection method of the input signal error detection function can be extended. Use this function to detect the input signal error only in the lower limit or upper limit, or to execute the disconnection detection.
Scaling functionThe A/D converter module scale-converts the output digital value to the set range of the scaling upper limit value and scaling lower limit value. This omits the programming of the scale conversion.
Shift functionThe A/D converter module adds the set shifting amount to conversion value to the scaling value (digital operation value) and stores in the buffer memory. Fine adjustment can be performed easily when the system starts.
Digital clipping functionWhen the input voltage or current exceeds the input range, the maximum value of the scaling value (digital operation value) can be set to 20000, and the minimum value can be set to 0 or -20000.
Logging functionThis function logs the digital output value or scaling value (digital operation value). The data of 10000 points can be logged for each channel.
Range switching function
The input range to use can be selected from the following ranges:• Factory default range (4 to 20mA, 0 to 20mA, 1 to 5V, 0 to 5V, -10 to 10V, 0 to 10V)• User range (User range setting)Extended mode range (4 to 20mA (Extended mode), 1 to 5V (Extended mode))
Sampling processing
Timeaverage
The A/D converter module executes the A/D conversion of the analog input value sequentially and stores the digital output value to the buffer memory.
Offset/gain setting function This function compensates for errors in digital output values.
The A/D converter module executes the A/D conversion for set time, and stores the average of the total value excluding the maximum and theminimum values to the buffer memory. The number of processing time within the setting time changes depending on the number of channelsused (the number of channels set to A/D conversion enabled).
Countaverage
Averagingprocessing
The A/D converter module executes the A/D conversion for set time, and stores the average of the total value excluding the maximumand the minimum values to the buffer memory. Time for the count average value stored in the buffer memory changes depending on theused channel numbers (the number of channels specified to A/D conversion enable).
Movingaverage
The A/D converter module averages digital output values of set number of times which are measured every sampling cycle, and stores them in the buffer memory.
Conversion speed switch function The conversion speed can be selected from 20μs, 80μs or 1ms.
Input range extended mode function
The input range can be extended. By combining this function with the input signal error detection function, simple disconnection detection can be executed.
Maximum value/minimum value hold function
The A/D converter module stores the maximum and minimum values of the scaling values (digital operation values) for each channel to the buffer memory.
Input signal error detection function This function detects the analog input value which exceeds the setting range.
Warning output function (process alarm)
This function outputs alarm when a scaling value (digital operation value) is in the range set in advance.
Difference conversion functionThis function subtracts the difference conversion reference value from the scaling value (digital operation value) and stores the acquired value in the buffer memory.
Flow amount integration function
This function performs the A/D conversion of analog input value (voltage or current) from a source such as a flow meter and integrates the scaling value (digital operation value).
Error log function The function stores up to latest 16 recodes of errors and alarms occurred in the A/D converter module to the buffer memory.
Module error collection function This function collects errors and alarms occurred in the A/D converter module and stores to the CPU module or the head module.
Error clear function Clearing the error from the system monitor at error occurrence is possible.
Saving and restoring offset/gain values The offset/gain value of the user range setting can be saved or restored.
···New function (New functions above are compatible with the A/D converter module whose first five serial number digits are 13041 or later.)
Function List
Data areanalyzed!
3
![Page 5: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.](https://reader035.fdocuments.in/reader035/viewer/2022081406/5f0e72967e708231d43f4ade/html5/thumbnails/5.jpg)
Point1 Item Specifications
4 points (4 channels)Number of analog input points
-10 to 10 VDC (input resistance 1M Ω)Analog input
Resolution
500μV
250μV
Analog input range Digital output value
0 to 10V
0 to 5V 0 to 20000
Absolute maximum input Voltage: ±15V, Current: 30mA*7
Offset/gain setting count*8 Up to 50000 counts
Isolation methodBetween I/O terminals and programmable controller power supply: photocoupler isolation
Between input channels: no isolation
Dielectric withstand voltage Between I/O terminals and programmable controller power supply: 500VACrms for 1 minute
Digital output
1 to 5V 200μV
-20000 to 20000
I/O characteristics, resolution*1
-20480 to 20479
When using the scaling function
Voltage
Current
Voltage
Current
-32768 to 32767
Ambient temperature0 to 55°C
Ambient temperature25±5°C Within ±0.1% (±20digit)
Within ±0.2% (±40digit)
High-speed: 20μs/channel
0 to 20mADC (input resistance 250 Ω)
-5000 to 22500
-20000 to 20000
-5000 to 22500
Accuracy(accuracy for themaximum value ofthe digital outputvalue)*3
-20000 to 20000
Conversion speed*4*5*6 Medium speed: 80μs/channel
Low speed: 1ms/channel
0 to 20000
-10 to 10V
1 to 5V (Extended mode)
4 to 20mA
User range setting
4 to 20mA (Extended mode)
User range setting
0 to 20mA
500μV
200μV
800nA
307μV*2
800nA
1230nA*2
1000nA
Insulation resistance Between I/O terminals and programmable controller power supply: 500VDC 10MΩ or higher
Number of occupied I/O points 16 points (I/O assignment: Intelligent 16 points)
R1.25-3 (solderless terminals with sleeve are not usable)
0.52A
0.19kg
Connected terminal 18-point terminal block
Applicable wire size
Applicable solderless terminal
Internal current consumption (5VDC)
Weight
0.3 to 0.75mm2
*1: For details on the I/O conversion characteristics, refer to the following.I/O conversion characteristic of A/D conversion in the manual.
*2: Maximum resolution in the user range setting.*3: Except when receiving noise influence.*4: The default value is 80μs/channel.*5: The logging function can be used only in the middle speed (80μs/channel) or low speed (1ms/channel).*6: The flow amount integration function can be used only in the low speed (1ms/channel).*7: This is a momentary current value which does not cause damage to internal resistors of the module. The maximum input current value
for constant application is 24mA.*8: If the number of offset/gain settings exceeds 50000 times, an error occurs.
Performance Specifications
Data areanalyzed!
4
![Page 6: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.](https://reader035.fdocuments.in/reader035/viewer/2022081406/5f0e72967e708231d43f4ade/html5/thumbnails/6.jpg)
HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANNAGOYA WORKS: 1-14, YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN
USA Mitsubishi Electric Automation lnc. Tel : +1-847-478-2100 500 Corporate Woods Parkway Vernon Hills, IL 60061, USA Fax : +1-847-478-2253
Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Tel : +55-11-3146-2200 Av Paulista, 1439-Cj. 72 Cerqueira Cesar CEP 01311-200, Fax : +55-11-3146-2217 Sao Paulo, SP, CEP:01311-200, Brazil
Germany Mitsubishi Electric Europe B.V. German Branch Tel : +49-2102-486-0 Gothaer Strasse 8 D-40880 Ratingen, Germany Fax : +49-2102-486-1120
UK Mitsubishi Electric Europe B.V. UK Branch Tel : +44-1707-276100 Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, UK Fax : +44-1707-278695
Italy Mitsubishi Electric Europe B.V. Italian Branch Tel : +39-039-60531 Viale Colleoni 7-20041 Agrate Brianza (Milano), Italy Fax : +39-039-6053312
Spain Mitsubishi Electric Europe B.V. Spanish Branch Tel : +34-93-565-3131 Carretera de Rubi 76-80 E-08190 Fax : +34-93-589-2948 Sant Cugat del Valles (Barcelona), Spain
France Mitsubishi Electric Europe B.V. French Branch Tel : +33-1-5568-5568 25,Boulevard des Bouvets, F-92741 Nanterre Cedex, France Fax : +33-1-5568-5757
Czech Republic Mitsubishi Electric Europe B.V.-o.s.-Czech office Tel : +420-251-551-470 Avenir Business Park, Radlická 714/113a CZ-158 00 Praha 5 Fax : +420-251-551-471
Poland Mitsubishi Electric Europe B.V. Polish Branch Tel : +48-12-630-47-00 ul. Krakowska 50 32-083 Balice, Poland Fax : +48-12-630-47-01
Russia Mitsubishi Electric Europe B.V. Russian Branch Tel : +7-812-633-3497 St.Petersburg office Fax : +7-812-633-3499 Sverdlovskaya emb., bld "Sch", BC "Benua", office 720; 195027, St.Petersburg, Russia
South Africa Circuit Breaker Industries Ltd. Tel : +27-11-977-0770 9 Derrick Road, Spartan,Gauteng PO Box 100, Fax : +27-11-977-0761 Kempton Park 1620, South Africa
China Mitsubishi Electric Automaiton (China) Ltd. Tel : +86-21-2322-3030 No.1386 Hongqiao Road, Fax : +86-21-2322-3000 Mitsubishi Electric Automation Center Shanghai China
Taiwan Setsuyo Enterprise Co., Ltd. Tel : +886-2-2299-2499 6F., No.105, Wugong 3rd, Wugu Dist, Fax : +886-2-2299-2509 New Taipei City 24889, Taiwan, R.O.C.
Korea Mitsubishi Electric Automation Korea Co., Ltd. Tel : +82-2-3660-9530 1480-6, Gayang-dong, Gangseo-ku Seoul 157-200, Korea Fax : +82-2-3664-8372
Singapore Mitsubishi Electric Asia Pte, Ltd. Tel : +65-6470-2480 307 Alexandra Road #05-01/02, Fax : +65-6476-7439 Mitsubishi Electric Bulding Singapore 159943
Thailand Mitsubishi Electric Automation (Thailand) Co., Ltd. Tel : +66-2-906-3238 Bang-Chan Industrial Estate No.111 Soi Serithai 54, Fax : +66-2-906-3239 T.Kannayao, A.Kannayao, Bangkok 10230 Thailand
Indonesia P.T. Autoteknindo Sumber Makmur Tel : +62-21-663-0833 Muara Karang Selatan Block A/Utara No.1 Kav. Fax : +62-21-663-0832 No.11 Kawasan Industri/Pergudangan Jakarta-Utara 14440, P.O Box5045 Jakarta 11050, Indonesia
India Mitsubishi Electric India Pvt. Ltd. Tel : +91-124-4630300 2nd Floor, DLF Building No.9B, DLF Cyber City Phase III, Fax : +91-124-4630399 Gurgaon 122002, Haryana, India
Australia Mitsubishi Electric Australia Pty.Ltd. Tel : +61-2-9684-7777 348 Victoria Road, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245
Country/Region Sales office Tel/Fax Country/Region Sales office Tel/Fax
1112 (MDOC) Specifications subject to change without notice.Printed in Japan on recycled paper.
Unit: mm
L60AD4
Point1Point1
Point2
Point4
Point3
Point2
Point3
Point4
95
DIN rail center
4
117 28.5
45
904
4
(45)
External Dimensions
Product List
MELSEC-L series analog-digital converter module
Product name Model
L60AD4