L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points!...

6
December 2011 No. 329EA Improve your production efficiency with convenient functions! New functions designed for ease of use are available! Improve your production efficiency with convenient functions! New functions designed for ease of use are available! L60AD4 Analog-digital converter module Mitsubishi Electric Programmable Controller Quickly calculate the flow amount! Logging function Point1 Point1 Point1 Point1 Point1 Log data for up to 10,000 points! Point2 Point2 Point2 Point2 Input signal error detection extension function The detection method of the input signal error detection function can be extended. Use this function to detect the input signal error only in the lower limit or upper limit, or to execute the disconnection detection. Input range extended mode function The input range can be extended. By combining this function with the input signal error detection function, simple disconnection detection can be executed. Expand detection methods to match your needs! New! New! Point4 Point4 Point4 Point4 Flow amount integration function The flow amount integration function executes the integral processing of input (instantaneous flow amount) from a flow meter and easily calculates the flow amount in a certain period. By registering/outputting the calculated flow amount, system operation can be improved and man-hours for programming can be reduced. New! Point3 Point3 Point3 Point3 Difference conversion function This function subtracts the difference conversion reference value from the scaling value (digital operation value) and stores the acquired value in the buffer memory. Easily measure part thicknesses! New! Logging cycle Minimum Maximum 80μs 3600s The data of 10,000 points can be logged for each channel. Data is continuously collected at the set cycle and stored in the buffer memory. Improve operability! Improve maintainability of control systems!

Transcript of L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points!...

Page 1: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.

December 2011

No. 329EA

Improve your production efficiency with convenient functions! New functions designed for ease of use are available!Improve your production efficiency with convenient functions! New functions designed for ease of use are available!

L60AD4

Analog-digital converter module

Mitsubishi Electric Programmable Controller

Quickly calculate the flow amount!

Logging function

Point1Point1Point1Point1Point1Log data for up to 10,000 points!

Point2Point2Point2Point2

Input signal error detection extension functionThe detection method of the input signal error detection function can be extended. Use this function to detect the input signal error only in the lower limit or upper limit, or to execute the disconnection detection.

Input range extended mode functionThe input range can be extended. By combining this function with the input signal error detection function, simple disconnection detection can be executed.

Expand detection methods to match your needs!

New!

New!

Point4Point4Point4Point4

Flow amount integration functionThe flow amount integration function executes the integral processing of input (instantaneous flow amount) from a flow meter and easily calculates the flow amount in a certain period. By registering/outputting the calculated flow amount, system operation can be improved and man-hours for programming can be reduced.

New!

Point3Point3Point3Point3

Difference conversion functionThis function subtracts the difference conversion reference value from the scaling value (digital operation value) and stores the acquired value in the buffer memory.

Easily measure part thicknesses! New!

Point2

Point3

Point4

Logging cycleMinimum

Maximum

80μs3600s

The data of 10,000 points can be logged for each channel.Data is continuously collected at the set cycle and stored in the buffer memory.

Improve operability!

Improve maintainability of control systems!

Page 2: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.

Point1Point1Point1 Log data for up to 10,000 points!

Data is continuously collected at the set cycle and stored in the buffer memory.Data stored in the buffer memory can be used for debugging, and to periodically confirm data variations.The data can be exported to Excel® allowing time-series data to be confirmed easily.

Logging function New!

Record inspection details

and analyze with the log data

Inspection of

part appearance

When data for 10,000 points has been stored, the data is overwritten from the 1st point data.

Buffer memory

1st data

2nd data

3rd data

4th data

5th data

6th data

9999th data

10000th data

Collected data

Storage of collected data

Unusual data can be analyzed.…

Improve maintainability with new functions!

Logging data can be transferred to the CPU device memory while still logging.Logging and data transmission can be executed simultaneously so the next inspection can be started right away.

Extract data without stopping logging!

A digital value unusual?

Data are displayedand analyzed on Excel®.

Collecting logging datausing MX Sheet.

Start the logging facility

Trigger occurred

Stop logging

Store data tothe buffer memory

· A large amount of data can be logged at high speed.A maximum speed of 80 μs, 10,000 points per channel.

· Conditions for the level trigger can be set.

· Logging points after the trigger can be set.

1. Above 2. Below 3. Pass through

Logging cycleMinimum 80μs

Maximum 3600s

Collected dataDigital output value

Scaling value(Digital operation value)

Number of collection points10,000 points

(Stored in buffer memory for each channel)

1st to 1000th data

1001st to 2000th data

2001st to 3000th data

3001st to 4000th data

4001st to 5000th data

5001st to 6000th data

6001st to 7000th data

7001st to 8000th data

8001st to 9000th data

9001st to 10000th data

1st to 1000th dataLogging completed area

L60AD4 CPU device memory

Logging area

Transfer

Logging standby area

While logging the 1001st to 2000th data, the 1st to the 1000th data is transferred to the CPU device memory by the ladder program.By transferring the data for every 1000 points, data for more than 10000 points can be logged.

[Continuous logging example]

Log data for more than 10,000 points!

Features

Improve maintainability of control systems!

Improve operability!

Transfer data for more than 10,000 points to the CPU!

So convenient!

Data areanalyzed!Data are

analyzed!

1

Page 3: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.

2

USA

Braz

Germ

UK

Italy

Spain

Fran

Czec

Polan

Russ

Coun

11

L60A

Point1Point1

Point2

Point4

Point3

It's convenient!In the flow amount integration function, the integration cycle can be set in 1ms.

Point2Point2Point2 Expand detection methods to match your needs!

The input signal error detection function includes detect only upper limit, detect only lower limit, and detect disconnection.

Input signal error detection extension function

Point3Point3Point3 Easily measure part thicknesses!

This function subtracts the difference conversion reference value from the scaling value (digital operation value) and stores the acquired value in the buffer memory.

When difference conversion starts, this module outputs the A/D conversion value at the start point as the difference conversion reference value, and stores the value obtained by subtracting the difference conversion reference value from the A/D conversion value as the scaling value. After that, the increment or decrement from the difference conversion reference value is stored in the scaling value.

Difference conversion function

Point4Point4Point4 Quickly calculate and record flow amount!

This function performs the A/D conversion of analog input value (voltage or current) from a flow meter and others, and integrates the scaling value (digital operation value) by every integration cycle. In this function, integral processing is performed regarding the scaling value (digital operation value) as the instantaneous flow amount.

Flow amount integration function

New!

The input range 4 to 20mA and 1 to 5V input valid range can be expanded.

Input range extended mode function New!

New!

New!

Measuresinstantaneous flowamount of liquid,and outputs the analog value

Flow meter, Control valveIntegratesinstantaneous flow amount

Liquid

Power conditioner

Heater

Detect voltages and currents exceeding the setting value!

Perform A/D conversion at high resolution.

Measure flatness and variation!

Easily check for irregularities!

E

P

MELanal

Page 4: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.

Point1 Item Description

A/D conversion enable/disable function

Sets whether to enable or disable A/D conversion for each channel.Disabling the A/D conversion for unused channels reduces the conversion cycles.

A/D conversionmethod

Input signal error detection extension function

The detection method of the input signal error detection function can be extended. Use this function to detect the input signal error only in the lower limit or upper limit, or to execute the disconnection detection.

Scaling functionThe A/D converter module scale-converts the output digital value to the set range of the scaling upper limit value and scaling lower limit value. This omits the programming of the scale conversion.

Shift functionThe A/D converter module adds the set shifting amount to conversion value to the scaling value (digital operation value) and stores in the buffer memory. Fine adjustment can be performed easily when the system starts.

Digital clipping functionWhen the input voltage or current exceeds the input range, the maximum value of the scaling value (digital operation value) can be set to 20000, and the minimum value can be set to 0 or -20000.

Logging functionThis function logs the digital output value or scaling value (digital operation value). The data of 10000 points can be logged for each channel.

Range switching function

The input range to use can be selected from the following ranges:• Factory default range (4 to 20mA, 0 to 20mA, 1 to 5V, 0 to 5V, -10 to 10V, 0 to 10V)• User range (User range setting)Extended mode range (4 to 20mA (Extended mode), 1 to 5V (Extended mode))

Sampling processing

Timeaverage

The A/D converter module executes the A/D conversion of the analog input value sequentially and stores the digital output value to the buffer memory.

Offset/gain setting function This function compensates for errors in digital output values.

The A/D converter module executes the A/D conversion for set time, and stores the average of the total value excluding the maximum and theminimum values to the buffer memory. The number of processing time within the setting time changes depending on the number of channelsused (the number of channels set to A/D conversion enabled).

Countaverage

Averagingprocessing

The A/D converter module executes the A/D conversion for set time, and stores the average of the total value excluding the maximumand the minimum values to the buffer memory. Time for the count average value stored in the buffer memory changes depending on theused channel numbers (the number of channels specified to A/D conversion enable).

Movingaverage

The A/D converter module averages digital output values of set number of times which are measured every sampling cycle, and stores them in the buffer memory.

Conversion speed switch function The conversion speed can be selected from 20μs, 80μs or 1ms.

Input range extended mode function

The input range can be extended. By combining this function with the input signal error detection function, simple disconnection detection can be executed.

Maximum value/minimum value hold function

The A/D converter module stores the maximum and minimum values of the scaling values (digital operation values) for each channel to the buffer memory.

Input signal error detection function This function detects the analog input value which exceeds the setting range.

Warning output function (process alarm)

This function outputs alarm when a scaling value (digital operation value) is in the range set in advance.

Difference conversion functionThis function subtracts the difference conversion reference value from the scaling value (digital operation value) and stores the acquired value in the buffer memory.

Flow amount integration function

This function performs the A/D conversion of analog input value (voltage or current) from a source such as a flow meter and integrates the scaling value (digital operation value).

Error log function The function stores up to latest 16 recodes of errors and alarms occurred in the A/D converter module to the buffer memory.

Module error collection function This function collects errors and alarms occurred in the A/D converter module and stores to the CPU module or the head module.

Error clear function Clearing the error from the system monitor at error occurrence is possible.

Saving and restoring offset/gain values The offset/gain value of the user range setting can be saved or restored.

···New function (New functions above are compatible with the A/D converter module whose first five serial number digits are 13041 or later.)

Function List

Data areanalyzed!

3

Page 5: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.

Point1 Item Specifications

4 points (4 channels)Number of analog input points

-10 to 10 VDC (input resistance 1M Ω)Analog input

Resolution

500μV

250μV

Analog input range Digital output value

0 to 10V

0 to 5V 0 to 20000

Absolute maximum input Voltage: ±15V, Current: 30mA*7

Offset/gain setting count*8 Up to 50000 counts

Isolation methodBetween I/O terminals and programmable controller power supply: photocoupler isolation

Between input channels: no isolation

Dielectric withstand voltage Between I/O terminals and programmable controller power supply: 500VACrms for 1 minute

Digital output

1 to 5V 200μV

-20000 to 20000

I/O characteristics, resolution*1

-20480 to 20479

When using the scaling function

Voltage

Current

Voltage

Current

-32768 to 32767

Ambient temperature0 to 55°C

Ambient temperature25±5°C Within ±0.1% (±20digit)

Within ±0.2% (±40digit)

High-speed: 20μs/channel

0 to 20mADC (input resistance 250 Ω)

-5000 to 22500

-20000 to 20000

-5000 to 22500

Accuracy(accuracy for themaximum value ofthe digital outputvalue)*3

-20000 to 20000

Conversion speed*4*5*6 Medium speed: 80μs/channel

Low speed: 1ms/channel

0 to 20000

-10 to 10V

1 to 5V (Extended mode)

4 to 20mA

User range setting

4 to 20mA (Extended mode)

User range setting

0 to 20mA

500μV

200μV

800nA

307μV*2

800nA

1230nA*2

1000nA

Insulation resistance Between I/O terminals and programmable controller power supply: 500VDC 10MΩ or higher

Number of occupied I/O points 16 points (I/O assignment: Intelligent 16 points)

R1.25-3 (solderless terminals with sleeve are not usable)

0.52A

0.19kg

Connected terminal 18-point terminal block

Applicable wire size

Applicable solderless terminal

Internal current consumption (5VDC)

Weight

0.3 to 0.75mm2

*1: For details on the I/O conversion characteristics, refer to the following.I/O conversion characteristic of A/D conversion in the manual.

*2: Maximum resolution in the user range setting.*3: Except when receiving noise influence.*4: The default value is 80μs/channel.*5: The logging function can be used only in the middle speed (80μs/channel) or low speed (1ms/channel).*6: The flow amount integration function can be used only in the low speed (1ms/channel).*7: This is a momentary current value which does not cause damage to internal resistors of the module. The maximum input current value

for constant application is 24mA.*8: If the number of offset/gain settings exceeds 50000 times, an error occurs.

Performance Specifications

Data areanalyzed!

4

Page 6: L60AD4 Analog-digital converter module Improve your ... · Point1 Log data for up to 10,000 points! Data is continuously collected at the set cycle and stored in the buffer memory.

HEAD OFFICE: TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANNAGOYA WORKS: 1-14, YADA-MINAMI 5, HIGASHI-KU, NAGOYA, JAPAN

USA Mitsubishi Electric Automation lnc. Tel : +1-847-478-2100 500 Corporate Woods Parkway Vernon Hills, IL 60061, USA Fax : +1-847-478-2253

Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Tel : +55-11-3146-2200 Av Paulista, 1439-Cj. 72 Cerqueira Cesar CEP 01311-200, Fax : +55-11-3146-2217 Sao Paulo, SP, CEP:01311-200, Brazil

Germany Mitsubishi Electric Europe B.V. German Branch Tel : +49-2102-486-0 Gothaer Strasse 8 D-40880 Ratingen, Germany Fax : +49-2102-486-1120

UK Mitsubishi Electric Europe B.V. UK Branch Tel : +44-1707-276100 Travellers Lane, Hatfield, Hertfordshire., AL10 8XB, UK Fax : +44-1707-278695

Italy Mitsubishi Electric Europe B.V. Italian Branch Tel : +39-039-60531 Viale Colleoni 7-20041 Agrate Brianza (Milano), Italy Fax : +39-039-6053312

Spain Mitsubishi Electric Europe B.V. Spanish Branch Tel : +34-93-565-3131 Carretera de Rubi 76-80 E-08190 Fax : +34-93-589-2948 Sant Cugat del Valles (Barcelona), Spain

France Mitsubishi Electric Europe B.V. French Branch Tel : +33-1-5568-5568 25,Boulevard des Bouvets, F-92741 Nanterre Cedex, France Fax : +33-1-5568-5757

Czech Republic Mitsubishi Electric Europe B.V.-o.s.-Czech office Tel : +420-251-551-470 Avenir Business Park, Radlická 714/113a CZ-158 00 Praha 5 Fax : +420-251-551-471

Poland Mitsubishi Electric Europe B.V. Polish Branch Tel : +48-12-630-47-00 ul. Krakowska 50 32-083 Balice, Poland Fax : +48-12-630-47-01

Russia Mitsubishi Electric Europe B.V. Russian Branch Tel : +7-812-633-3497 St.Petersburg office Fax : +7-812-633-3499 Sverdlovskaya emb., bld "Sch", BC "Benua", office 720; 195027, St.Petersburg, Russia

South Africa Circuit Breaker Industries Ltd. Tel : +27-11-977-0770 9 Derrick Road, Spartan,Gauteng PO Box 100, Fax : +27-11-977-0761 Kempton Park 1620, South Africa

China Mitsubishi Electric Automaiton (China) Ltd. Tel : +86-21-2322-3030 No.1386 Hongqiao Road, Fax : +86-21-2322-3000 Mitsubishi Electric Automation Center Shanghai China

Taiwan Setsuyo Enterprise Co., Ltd. Tel : +886-2-2299-2499 6F., No.105, Wugong 3rd, Wugu Dist, Fax : +886-2-2299-2509 New Taipei City 24889, Taiwan, R.O.C.

Korea Mitsubishi Electric Automation Korea Co., Ltd. Tel : +82-2-3660-9530 1480-6, Gayang-dong, Gangseo-ku Seoul 157-200, Korea Fax : +82-2-3664-8372

Singapore Mitsubishi Electric Asia Pte, Ltd. Tel : +65-6470-2480 307 Alexandra Road #05-01/02, Fax : +65-6476-7439 Mitsubishi Electric Bulding Singapore 159943

Thailand Mitsubishi Electric Automation (Thailand) Co., Ltd. Tel : +66-2-906-3238 Bang-Chan Industrial Estate No.111 Soi Serithai 54, Fax : +66-2-906-3239 T.Kannayao, A.Kannayao, Bangkok 10230 Thailand

Indonesia P.T. Autoteknindo Sumber Makmur Tel : +62-21-663-0833 Muara Karang Selatan Block A/Utara No.1 Kav. Fax : +62-21-663-0832 No.11 Kawasan Industri/Pergudangan Jakarta-Utara 14440, P.O Box5045 Jakarta 11050, Indonesia

India Mitsubishi Electric India Pvt. Ltd. Tel : +91-124-4630300 2nd Floor, DLF Building No.9B, DLF Cyber City Phase III, Fax : +91-124-4630399 Gurgaon 122002, Haryana, India

Australia Mitsubishi Electric Australia Pty.Ltd. Tel : +61-2-9684-7777 348 Victoria Road, Rydalmere, N.S.W 2116, Australia Fax : +61-2-9684-7245

Country/Region Sales office Tel/Fax Country/Region Sales office Tel/Fax

1112 (MDOC) Specifications subject to change without notice.Printed in Japan on recycled paper.

Unit: mm

L60AD4

Point1Point1

Point2

Point4

Point3

Point2

Point3

Point4

95

DIN rail center

4

117 28.5

45

904

4

(45)

External Dimensions

Product List

MELSEC-L series analog-digital converter module

Product name Model

L60AD4