KX-HGT100 SIP-Phone
description
Transcript of KX-HGT100 SIP-Phone
KX-HGT100 SIP-Phone
KX-HGT100 Configuration (1)
User name: KX-HGT100
Password: kx-hgt100
1. Connect the HGT100 to the LAN via a suitable switch port
2. Power on the unit (using PoE or the optional AC Adaptor)
3. Check the LCD Display shows “Not configured
Web Setting”
4. Using your Browser (Internet Explorer etc), access http://192.168.0.241/
Not Configured
Web Setting
KX-HGT100 Configuration (2)
Unit has no Profile set.
Registration is not possible
Unit Status:
KX-HGT100 Configuration (3)
STATIC IP is set by default
Default IP:
192.168.0.241
Default Subnet Mask 255.255.255.0
Network Status:
KX-HGT100 Configuration (4)LAN Connection:
STATIC IP or DHCP Mode can be selected.
(Static IP is Default = X )
NB: If you select ‘DHCP’ here, you will need to re-connect your browser using the allocated IP address before continuing to configure.
KX-HGT100 Configuration (5)
Enter IP Address etc of HGT100 here
DNS Server Address can be added here
(not required for TDE/NCP)
After clicking ‘Save’, please power off/on the HGT-100
KX-HGT100 Configuration (6)
NB: When using DHCP, ensure that the PC connected to the PC-Port is on the same network segment as the HGT-100, otherwise Internet access from the PC will not be possible.
The allocated IP address can be checked by pressing the [i+] key on the HGT-100.
To re-connect with a browser (after enabling DHCP), enter the allocated IP address)
i.e. Allocated IP address 10.66.55.44
URL:http://10.66.55.44/
After clicking ‘Save’, power off/on the HGT-100.
KX-HGT100 Configuration (7)Username and Password:
Modifies the HTTP Login User name and Password from default
If Idle Timeout expires, unit will need to be powered off/on to re-open HTTP port. (“Special” Setting)
KX-HGT100 Configuration (8)Basic Settings:
Refer to next slide for language parameters;
SIP Extension details and password (Telephone Number and SIP ID can match)
SIP Proxy, Registrar and Domain information.
For NCP Extension, enter the IP address of the NCP for all settings.
KX-HGT100 Configuration (9)Basic Settings: (Example)
(Stand-Alone SIP Telephone configuration with Gamma SIP Account)
SIP Number, Account and password.
SIP Proxy, Registrar and Domain (IP or DNS).
KX-HGT100 Configuration (11)Advanced Settings:
One Time Caller Code either Permits or Denies CLIP sending on a per call basis, depending on the “My Caller ID” setting of the HGT100.
RTP Port Range (Voice Traffic)
Codec Priority:
PCMA/U = G711A/U
G726-32 (N/A for TDA/NCP)
G729A
DTMF Type: Inband/Outband(RFC2833)
SIP UDP Control port
Diffserv(ToS) field settings
KX-HGT100 Configuration (14)Configuration File:
Basic Configurations can be backed-up and/or loaded via this screen.
This allows a dealer to create a profile template and then modify only a small number of parameters (Number/Password etc)
KX-HGT100 Configuration (15)Upgrade Firmware:
Firmware updates can be managed easily from this page.
Power off/on the unit to complete the upgrade.
KX-HGT100 Configuration (16)Unit Maintenance:
Lan/PC Port.
Speed/Duplex Settings;
Auto Negotiate
100Mbps/Full Duplex
100Mbps/Half Duplex
10Mbps/Full Duplex
10Mbps/Half Duplex
Auto Sense is supported.
‘PROGRAM’ KEY
LCD DISPLAY
‘NAVI’ KEY
‘INFORMATION’ KEY
‘MUTE’ KEY
KX-HGT100 User Setting (1)
‘OK’ KEY
AUTO HOLD Message Transfer
‘SP-Phone ‘KeySP-Phone, Hold and Message Keys have LED.‘REDIAL’ KEY
Save Speed Dial?
[OK]=YES
KX-HGT100 User Setting (2)
Saved in No. 1
Select OKPROGRAM
Enter No. 1
No. 1 [OK]=SET
0123456789
Speed dial 0 ~ 9
1
How to access :-
‘OFF-HOOK’
Keys used:
1.
AUTO
Set Date + Time
[OK]=YES
KX-HGT100 User Setting (3)
Enter Year 2008
[OK]
Enter Month/Day
05/07 [OK]
Enter Time
17:30 [OK]
▲▼= AM/PM/24H
17:30PM [OK]
My Caller ID
(Show) [OK]=YESOK Select
Show/HideOK
CLIR (Show/Hide)
2.
3.
KX-HGT100 User Setting (4)
LCD contrast ?
[OK]=YES
4.
- ██████ +
[OK]=YES
Select
4 STEPS
Ringer Tone ?
Ring 1 [OK]=YES
5.
Ringer Tone ?
Ring 2 [OK]=YES
Select
3 STYLES
Ringer Volume ?
Ring 1 [OK]=YES
6.
Ringer Volume [OK]
OFF - █████ +Select
4 Position + ‘OFF’‘OFF’ = SP-Phone LED Flashes
KX-HGT100 User Setting (5)7.
Set Hold Music ?
(#01) [OK]=YESSelectOK
#11 Settings (Inc ‘OFF’)
8.
KeyTone Volume ?
[OK]=YES
Keytone Volume
OFF - ███ + [OK]Select
3 Settings (Inc ‘OFF’)
Time AM/PM 24H
(AM) [OK]=YES
9.
OK Select AM/PM/24H
KX-HGT100 User Setting (6)10.
Change Language ?
English [OK]OK Select
Refer to Slide #14 for supported languages
Set Network ?
(STATIC) [OK]=YES
11.
OK Select
STATIC IP
Or
DHCP
IP Address [OK]
192.168.010.003
Subnet Mask [OK]
255.255.255.0
Default GW [OK]
192.168.000.001
KX-HGT100 User Setting (7)
Select
IP Address192.168.010.003
Subnet Mask255.255.255.0
Default Gateway192.168.000.001
INFORMATION
Own number01234
1
StatusNormal
2
NetworkSTATIC
3
6
5
4
KX-HGT100 ‘Special’ setting (1)‘Special’ Settings:
Factory Default:
To return the unit to it’s factory default settings, press
[Program] + [OK] + [Mute] and power-on the unit.
If successful, “Not Configured Web Setting” will be displayed in the LCD.
HTTP Port open:
To re-open the HTTP Port after initial setting or Idle time-out (default 30min)
[OK] + [Mute] and power-on the unit.
Firmware Roll-back:
To rollback the firmware to the previously installed version
[Program] + [Mute] and power-on the unit.