KW DPL832.K1 1 Version 1.2 | 2019-07-15 www.osram-os.com Applications KW DPL832.K1 SYNIOS ® E4014 Displays (Backlighting) Features: Package: SMD epoxy package, colored silicone resin Chip technology: InGaN on Sapphire Typ. Radiation: 120° (Lambertian emitter) Color: Cx = 0.28, Cy = 0.26 acc. to CIE 1931 ( multiphosphor white) Corrosion Robustness Class: 1B Qualifications: AEC-Q102 Qualified ESD: 8 kV acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 3B)

Transcript of KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1...

Page 1: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

1 Version 1.2 | 2019-07-15

Produktdatenblatt | Version 1.1 www.osram-os.com

Applications

KW DPL832.K1

SYNIOS® E4014

— Displays (Backlighting)

Features: — Package: SMD epoxy package, colored silicone resin

— Chip technology: InGaN on Sapphire

— Typ. Radiation: 120° (Lambertian emitter)

— Color: Cx = 0.28, Cy = 0.26 acc. to CIE 1931 (● multiphosphor white)

— Corrosion Robustness Class: 1B

— Qualifications: AEC-Q102 Qualified

— ESD: 8 kV acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 3B)

Page 2: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

2 Version 1.2 | 2019-07-15

Ordering Information

Type Luminous Flux 1) Ordering CodeIF = 100 mAΦV

KW DPL832.K1-7J6K-DEGL-L1-39 56 ... 90 lm Q65112A9111

Page 3: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

3 Version 1.2 | 2019-07-15

Maximum RatingsParameter Symbol Values

Operating Temperature Top min. max.

-40 °C100 °C

Storage Temperature Tstg min. max.

-40 °C100 °C

Junction Temperature Tj max. 120 °C

Forward Current TS = 25 °C

IF min. max.

5 mA240 mA

ESD withstand voltage acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 3B)

VESD 8 kV

Reverse voltage 2) VR Not designed for reverse operation

Page 4: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

4 Version 1.2 | 2019-07-15

CharacteristicsIF = 100 mA; TS = 25 °C

Parameter Symbol Values

Chromaticity Coordinate 3) Cx Cy

typ. typ.

0.280.26

Peak Wavelength IF = 100 mA

λpeak min. max.

443 nm453 nm

Viewing angle at 50% IV 2φ typ. 120 °

Forward Voltage 4) IF = 100 mA

VF min. typ. max.

5.60 V6.05 V6.30 V

Reverse current 2) IR Not designed for reverse

operation

Real thermal resistance junction/solderpoint 5) RthJS real typ. max.

20 K / W40 K / W

Electrical thermal resistance junction/solderpoint 5) with efficiency ηe = 45 %

RthJS elec. typ. max.

11 K / W22 K / W

Page 5: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

5 Version 1.2 | 2019-07-15

Brightness Groups

Group Luminous Flux 1) Luminous Flux 1) Luminous Intensity 6)

IF = 100 mA IF = 100 mA IF = 100 mAmin. max. typ.ΦV ΦV Iv

7J 56 lm 63 lm 20 cd

8J 63 lm 71 lm 23 cd

5K 71 lm 80 lm 26 cd

6K 80 lm 90 lm 29 cd

Forward Voltage Groups

Group Forward Voltage 4) Forward Voltage 4)

IF = 100 mA IF = 100 mAmin. max.VF VF

3 5.60 V 5.70 V

4 5.70 V 5.80 V

5 5.80 V 5.90 V

6 5.90 V 6.00 V

7 6.00 V 6.10 V

8 6.10 V 6.20 V

9 6.20 V 6.30 V

Wavelength Groups

Group Peak Wavelength Peak Wavelength IF = 100 mA IF = 100 mAmin. max.λpeak λpeak

L1 443 nm 453 nm

Page 6: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

6 Version 1.2 | 2019-07-15

Chromaticity Coordinate GroupsKW DPL832.K1

0.0 0.2 0.4 0.6Cx

0.25 0.26 0.27 0.28 0.29 0.30

Cx

0.0

0.2

0.4

0.6

0.8Cy

0.20

0.22

0.24

0.26

0.28

0.30

0.32

Cy

400 -380 nm

500 nm

550 nm

600 nm

700 -750 nm

DEDF

DGDH

DJDK

DLDM

DNDP

EEEF

EGEH

EJEK

ELEM

ENEP

FEFF

FGFH

FJFK

FLFM

FNFP

GEGF

GGGH

GJGK

GLGM

GNGP

Page 7: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

7 Version 1.2 | 2019-07-15

Chromaticity Coordinate Groups Group Cx Cy

DE 0.2520 0.2040

0.2570 0.2132

0.2570 0.2032

0.2520 0.1940

DF 0.2570 0.2132

0.2620 0.2224

0.2620 0.2124

0.2570 0.2032

DG 0.2620 0.2224

0.2670 0.2316

0.2670 0.2216

0.2620 0.2124

DH 0.2670 0.2316

0.2720 0.2408

0.2720 0.2308

0.2670 0.2216

DJ 0.2720 0.2408

0.2770 0.2500

0.2770 0.2400

0.2720 0.2308

DK 0.2770 0.2500

0.2820 0.2592

0.2820 0.2492

0.2770 0.2400

DL 0.2820 0.2592

0.2870 0.2684

0.2870 0.2584

0.2820 0.2492

EE 0.2520 0.2140

0.2570 0.2232

0.2570 0.2132

0.2520 0.2040

Group Cx Cy

EF 0.2570 0.2232

0.2620 0.2324

0.2620 0.2224

0.2570 0.2132

EG 0.2620 0.2324

0.2670 0.2416

0.2670 0.2316

0.2620 0.2224

EH 0.2670 0.2416

0.2720 0.2508

0.2720 0.2408

0.2670 0.2316

EJ 0.2720 0.2508

0.2770 0.2600

0.2770 0.2500

0.2720 0.2408

EK 0.2770 0.2600

0.2820 0.2692

0.2820 0.2592

0.2770 0.2500

EL 0.2820 0.2692

0.2870 0.2784

0.2870 0.2684

0.2820 0.2592

FE 0.2520 0.2240

0.2570 0.2332

0.2570 0.2232

0.2520 0.2140

FF 0.2570 0.2332

0.2620 0.2424

0.2620 0.2324

0.2570 0.2232

Group Cx Cy

FG 0.2620 0.2424

0.2670 0.2516

0.2670 0.2416

0.2620 0.2324

FH 0.2670 0.2516

0.2720 0.2608

0.2720 0.2508

0.2670 0.2416

FJ 0.2720 0.2608

0.2770 0.2700

0.2770 0.2600

0.2720 0.2508

FK 0.2770 0.2700

0.2820 0.2792

0.2820 0.2692

0.2770 0.2600

FL 0.2820 0.2792

0.2870 0.2884

0.2870 0.2784

0.2820 0.2692

GE 0.2520 0.2340

0.2570 0.2432

0.2570 0.2332

0.2520 0.2240

GF 0.2570 0.2432

0.2620 0.2524

0.2620 0.2424

0.2570 0.2332

GG 0.2620 0.2524

0.2670 0.2616

0.2670 0.2516

0.2620 0.2424

Page 8: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

8 Version 1.2 | 2019-07-15

Group Cx Cy

GH 0.2670 0.2616

0.2720 0.2708

0.2720 0.2608

0.2670 0.2516

GJ 0.2720 0.2708

0.2770 0.2800

0.2770 0.2700

0.2720 0.2608

Group Cx Cy

GK 0.2770 0.2800

0.2820 0.2892

0.2820 0.2792

0.2770 0.2700

GL 0.2820 0.2892

0.2870 0.2984

0.2870 0.2884

0.2820 0.2792

Page 9: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

9 Version 1.2 | 2019-07-15

Group Name on Label Example: 5K-DE-L1-3Brightness Color Chromaticity Wavelength Groups Forward Voltage

5K DE L1 3

Page 10: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

10 Version 1.2 | 2019-07-15

Relative Spectral Emission 6)

Φrel = f (λ); IF = 100 mA; TS = 25 °C

KW DPL832.K1

350 400 450 500 550 600 650 700 750 800

λ /

0.0

0.2

0.4

0.6

0.8

1.0Φ: Vλ

: white

Radiation Characteristics 6)

Irel = f (ϕ); TS = 25 °CKW DPL832.K1

-100°

-90°

-80°

-70°

-60°

-50°

-40°

-30°

-20°-10° 0° 10° 20° 30° 40° 50° 60° 70° 80° 90°

ϕ /

0.0

0.2

0.4

0.6

0.8

1.0I

: 0°: 90°

Page 11: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

11 Version 1.2 | 2019-07-15

Forward current 6)

IF = f(VF); TS = 25 °CKW DPL832.K1

5.1 5.4 5.6 5.8 6.0 6.2 6.4 6.6

VF / V

5

20

40

60

80

100

120

140

160

180IF / mA

Relative Luminous Flux 6), 7)

Φv/Φv(100 mA) = f(IF); TS = 25 °CKW DPL832.K1

5 20 40 60 80 100

120

140

160

180

IF / mA

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8ΦV

ΦV(100mA)

Chromaticity Coordinate Shift 6)

ΔCx, ΔCy = f(IF); TS = 25 °CKW DPL832.K1

5 20 40 60 80 100

120

140

160

180

IF / mA

-0.03

-0.02

-0.01

0.00

0.01

0.02

0.03∆Cx∆Cy : ∆ Cx

: ∆ Cy

Page 12: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

12 Version 1.2 | 2019-07-15

Forward Voltage 6)

ΔVF = VF - VF(25 °C) = f(Tj); IF = 100 mAKW DPL832.K1

-40 -20 0 20 40 60 80 100 120

Tj / °C

-0.4

-0.2

0.0

0.2

0.4

∆VF / V

Relative Luminous Flux 6)

Φv/Φv(25 °C) = f(Tj); IF = 100 mAKW DPL832.K1

-40 -20 0 20 40 60 80 100 120

Tj / °C

0.0

0.2

0.4

0.6

0.8

1.0

1.2Φv

Φv(25°C)

Chromaticity Coordinate Shift 6)

ΔCx, ΔCy = f(Tj); IF = 100 mAKW DPL832.K1

-40 -20 0 20 40 60 80 100 120

Tj / °C

-0.03

-0.02

-0.01

0.00

0.01

0.02

0.03∆Cx∆Cy : ∆ Cx

: ∆ Cy

Page 13: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

13 Version 1.2 | 2019-07-15

Max. Permissible Forward CurrentIF = f(T)

0 20 40 60 80 100

T / °C

0

20

40

60

80

100

120

140

160

180

200

220

240

260IF / mA

KW DPL832.K1

: Ts

Permissible Pulse Handling CapabilityIF = f(tp); D: Duty cycle

10-6 10-5 10-4 10-3 0.01 0.1 1 10

/

0.22

0.24

0.26

0.28

0.30IF / A

TS = 0°C ... 70°CKW DPL832.K1

: D = 1.0: D = 0.5: D = 0.2: D = 0.1: D = 0.05: D = 0.02: D = 0.01: D = 0.005

Permissible Pulse Handling CapabilityIF = f(tp); D: Duty cycle;

10-6 10-5 10-4 10-3 0.01 0.1 1 10

/

0.10

0.15

0.20

0.25

0.30IF / A

TS = 100°CKW DPL832.K1

: D = 1.0: D = 0.5: D = 0.2: D = 0.1: D = 0.05: D = 0.02: D = 0.01: D = 0.005

Page 14: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

14 Version 1.2 | 2019-07-15

Dimensional Drawing 8)

Further Information

Approximate Weight: 9.0 mg

Package marking: Cathode

Corrosion test: Class: 1B Test condition: 25°C / 75 % RH / 200ppb SO2, 200ppb NO2, 10ppb H2S, 10ppb Cl2 / 21 days (EN 60068-2-60 (Method 4))

ESD advice: The device is protected by ESD device which is connected in parallel to the Chip.

Page 15: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

15 Version 1.2 | 2019-07-15

Electrical Internal Circuit

Page 16: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

16 Version 1.2 | 2019-07-15

Recommended Solder Pad 8)

For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning.

Page 17: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

17 Version 1.2 | 2019-07-15

Reflow Soldering ProfileProduct complies to MSL Level 3 acc. to JEDEC J-STD-020E

00

s

OHA04525

50

100

150

200

250

300

50 100 150 200 250 300t

T

˚C

St

t

Pt

Tp240 ˚C

217 ˚C

245 ˚C

25 ˚C

L

Profile Feature Symbol Pb-Free (SnAgCu) Assembly UnitMinimum Recommendation Maximum

Ramp-up rate to preheat*)

25 °C to 150 °C2 3 K/s

Time tSTSmin to TSmax

tS 60 100 120 s

Ramp-up rate to peak*)

TSmax to TP

2 3 K/s

Liquidus temperature TL 217 °C

Time above liquidus temperature tL 80 100 s

Peak temperature TP 245 260 °C

Time within 5 °C of the specified peaktemperature TP - 5 K

tP 10 20 30 s

Ramp-down rate*TP to 100 °C

3 6 K/s

Time25 °C to TP

480 s

All temperatures refer to the center of the package, measured on the top of the component* slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range

Page 18: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

18 Version 1.2 | 2019-07-15

Taping 8)

Page 19: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

19 Version 1.2 | 2019-07-15

Tape and Reel 9)

Reel DimensionsA W Nmin W1 W2 max Pieces per PU

180 mm 12 + 0.3 / - 0.1 mm 60 mm 12.4 + 2 mm 18.4 mm 2000

Page 20: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

20 Version 1.2 | 2019-07-15

Barcode-Product-Label (BPL)

Dry Packing Process and Materials 8)

OHA00539

OSRAM

Moisture-sensitive label or print

Barcode label

Desiccant

Humidity indicator

Barcode label

OSRAM

Please check the HIC immidiately afterbag opening.

Discard if circles overrun.Avoid metal contact.

WET

Do not eat.

Comparatorcheck dot

parts still adequately dry.

examine units, if necessary

examine units, if necessary

5%

15%

10%bake units

bake units

If wet,

change desiccant

If wet,

Humidity IndicatorMIL-I-8835

If wet,

Mois

ture

Level 3

Flo

or tim

e 168 H

ours

Mois

ture

Level 6

Flo

or tim

e 6

Hours

a) H

umid

ity In

dicato

r C

ard is

> 1

0% w

hen read a

t 23 ˚

C ±

5 ˚C

, or

reflo

w, v

apor-phase r

eflow

, or equiv

alent p

rocessin

g (peak p

ackage

2. Afte

r th

is b

ag is o

pened, devic

es that w

ill b

e subje

cted to

infrare

d

1. Shelf

life in

seale

d bag: 2

4 month

s at <

40 ˚

C a

nd < 9

0% rela

tive h

umid

ity (R

H).

Mois

ture

Level 5

a

at facto

ry c

onditions o

f

(if b

lank, s

eal date

is id

entical w

ith d

ate c

ode).

a) M

ounted w

ithin

b) S

tore

d at

body tem

p.

3. Devic

es require

bakin

g, befo

re m

ounting, i

f:

Bag s

eal date

Mois

ture

Level 1

Mois

ture

Level 2

Mois

ture

Level 2

a4. If b

aking is

require

d,

b) 2a o

r 2b is

not m

et.

Date

and ti

me o

pened:

refe

rence IP

C/J

ED

EC

J-S

TD

-033 fo

r bake p

rocedure

.

Flo

or tim

e see b

elow

If bla

nk, see b

ar code la

bel

Flo

or tim

e > 1

Year

Flo

or tim

e 1

Year

Flo

or tim

e 4

Weeks10%

RH

.

_<

Mois

ture

Level 4

Mois

ture

Level 5

˚C).

OPTO

SEM

ICO

NDUCTORS

MO

ISTURE S

ENSITIV

E

This b

ag conta

ins

CAUTION

Flo

or tim

e 72 H

ours

Flo

or tim

e 48 H

ours

Flo

or tim

e 24 H

ours

30 ˚C

/60%

RH

.

_<

LE

VE

L

If bla

nk, see

bar code la

bel

Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card according JEDEC-STD-033.

Page 21: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

21 Version 1.2 | 2019-07-15

Schematic Transportation Box 8)

OHA02044

PACKVAR:

R077Additional TEXT

P-1+Q-1

Multi TOPLED

Muste

r

OSRAM Opto

Semiconductors

(6P) BATCH NO:

(X) PROD NO:

10

(9D) D/C:

11(1T) LOT NO:

210021998

123GH1234

024 5

(Q)QTY: 2000

0144

(G) GROUP:

260 C RT240 C R

3

220 C R

MLBin3:Bin2: Q

-1-20

Bin1: P-1-20

LSY T6762

2a

Temp ST

R18DEMY

PACKVAR:

R077Additional TEXT

P-1+Q-1

Multi TOPLED

Muste

r

OSRAM Opto

Semiconductors

(6P) BATCH NO:

(X) PROD NO:

10

(9D) D/C:

11(1T) LOT NO:

210021998

123GH1234

024 5

(Q)QTY: 2000

0144

(G) GROUP:

260 C RT240 C R

3

220 C R

MLBin3:Bin2: Q

-1-20

Bin1: P-1-20

LSY T6762

2a

Temp ST

R18DEMY

OSRAM

Packing

Sealing label

Barcode label

Mois

ture

Level 3

Flo

or tim

e 168 H

ours

Mois

ture

Level 6

Flo

or tim

e 6

Hours

a) H

umid

ity In

dicato

r C

ard is

> 1

0% w

hen read a

t 23 ˚

C ±

5 ˚C

, or

reflo

w, v

apor-phase r

eflow

, or e

quivale

nt pro

cessing (p

eak package

2. Afte

r th

is b

ag is o

pened,

devices th

at will

be s

ubjecte

d to in

frare

d

1. Shelf

life in

seale

d bag: 2

4 month

s at <

40 ˚

C a

nd < 9

0% rela

tive h

umid

ity (R

H).

Mois

ture

Level 5

a

at facto

ry c

onditions o

f

(if b

lank, s

eal date

is id

entical w

ith d

ate c

ode).

a) M

ounted w

ithin

b) S

tore

d at

body te

mp.

3. Devic

es require

bakin

g, befo

re m

ounting, i

f:

Bag s

eal date

Mois

ture

Level 1

Mois

ture

Level 2

Mois

ture

Level 2

a4. If b

aking is

require

d,

b) 2a o

r 2b is

not m

et.

Date

and ti

me o

pened:

refe

rence IP

C/J

ED

EC

J-S

TD-0

33 for bake p

rocedure

.

Floor

time s

ee belo

w

If bla

nk, see b

ar code la

bel

Flo

or tim

e > 1

Year

Floor

time

1 Y

ear

Flo

or tim

e 4

Weeks10%

RH

.

_<

Mois

ture

Level 4

Mois

ture

Level 5

˚C).

OPTO

SEM

ICONDUCTO

RS

MO

ISTURE S

ENSITIV

E

This b

ag conta

ins

CAUTION

Flo

or tim

e 72 H

ours

Flo

or tim

e 48 H

ours

Flo

or tim

e 24 H

ours

30 ˚C

/60%

RH

.

_<

LE

VE

L

If bla

nk, see

bar code la

bel

Barcode label

Dimensions of Transportation BoxWidth Length Height

195 ± 5 mm 195 ± 5 mm 30 ± 5 mm

Page 22: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

22 Version 1.2 | 2019-07-15

NotesThe evaluation of eye safety occurs according to the standard IEC 62471:2006 (photo biological safety of lamps and lamp systems). Within the risk grouping system of this IEC standard, the device specified in this data sheet falls into the class moderate risk (exposure time 0.25 s). Under real circumstances (for exposure time, conditions of the eye pupils, observation distance), it is assumed that no endangerment to the eye ex-ists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. When looking at bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoy-ance, visual impairment, and even accidents, depending on the situation.

Subcomponents of this device contain, in addition to other substances, metal filled materials including silver. Metal filled materials can be affected by environments that contain traces of aggressive substances. There-fore, we recommend that customers minimize device exposure to aggressive substances during storage, production, and use. Devices that showed visible discoloration when tested using the described tests above did show no performance deviations within failure limits during the stated test duration. Respective failure limits are described in the IEC60810.

For further application related information please visit www.osram-os.com/appnotes

Page 23: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

23 Version 1.2 | 2019-07-15

Disclaimer

Attention please!The information describes the type of component and shall not be considered as assured characteristics.Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances.For information on the types in question please contact our Sales Organization.If printed or downloaded, please find the latest version on the OSRAM OS website.

PackingPlease use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred

Product and functional safety devices/applications or medical devices/applicationsOSRAM OS components are not developed, constructed or tested for the application as safety relevant component or for the application in medical devices.OSRAM OS products are not qualified at module and system level for such application.

In case Buyer – or Customer supplied by Buyer – considers using OSRAM OS components in product safe-ty devices/applications or medical devices/applications, Buyer and/or Customer has to inform the local sales Partner of OSRAM OS immediately and OSRAM OS and Buyer and /or Customer will analyze and coordi-nate the customer-specific request between OSRAM OS and Buyer and/or Customer.

Page 24: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

24 Version 1.2 | 2019-07-15

Glossary1) Brightness: Brightness values are measured during a current pulse of typically 60 ms, with an internal

reproducibility of ±8 % and an expanded uncertainty of ±11 % (acc. to GUM with a coverage factor of k = 3).

2) Reverse Operation: Not designed for reverse operation. Continuous reverse operation can cause mi-gration and damage of the device.

3) Chromaticity coordinate groups: Chromaticity coordinates are measured during a current pulse of typically 60 ms, with an internal reproducibility of ±0.005 and an expanded uncertainty of ±0.01 (acc. to GUM with a coverage factor of k = 3).

4) Forward Voltage: The forward voltage is measured during a current pulse of typically 43 ms, with an internal reproducibility of ±0.05 V and an expanded uncertainty of ±0.1 V (acc. to GUM with a coverage factor of k = 3).

5) Thermal Resistance: Rth max is based on statistic values (6σ).6) Typical Values: Due to the special conditions of the manufacturing processes of semiconductor devic-

es, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could dif-fer from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice.

7) Characteristic curve: In the range where the line of the graph is broken, you must expect higher differ-ences between single devices within one packing unit.

8) Tolerance of Measure: Unless otherwise noted in drawing, tolerances are specified with ±0.1 and dimensions are specified in mm.

9) Tape and Reel: All dimensions and tolerances are specified acc. IEC 60286-3 and specified in mm.

Page 25: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

25 Version 1.2 | 2019-07-15

Revision HistoryVersion Date Change

1.0 2019-04-01 Initial Version

1.1 2019-04-18 Brightness Groups

1.2 2019-07-15 Ordering Information Chromaticity Coordinate Groups

Page 26: KW DPL832 - Osram · KW DPL832.K1 1 Version 1.2 | 2019-07-15 Produktdatenblatt | Version 1.1 Applications KW DPL832.K1 SYNIOS ® E4014 — Displays (Backlighting) Features: — Package:

KW DPL832.K1

26 Version 1.2 | 2019-07-15

Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved.