Kuterlex Plastic Coated Copper Tube to BS EN 13349/1057
Kuterlex is copper tube coated with a seamless plastic cover which protects the copper tube against aggressive materials. The Kuterlex cover eliminates time-consuming wrapping operations. It is also colour coded to identify the services carried in accordance with UK local authority specifications and BS 1710: 1984, “Specification for identification of pipelines and services”.
STandard feaTUreS
• Cu-DHPgradecopper
• ManufacturedinaccordancewithBSEN13349(specification for covered copper tube)
• CoppertubetoBSEN1057
• BSiKitemarklicensed(coppertube)
• 25yearguaranteeagainstproductfailuredirectlyattributable to a manufacturing defect
• Straightlengthsavailablein5.8mlengthsforcontainerloads to export markets
BenefITS
• Reducesinstallationtime
• Protectsthecoppertubeagainst aggressive materials
• Protectsthecoppertubeagainstaccidental damage and abrasion
• Plasticcoveringwithstandswaterservice temperaturesupto95°C
• Coveringremainsflexibledownto-60°C
• Colourcodedforserviceidentification: -Coldwaterservices,greenorblue - Gas services, yellow
- General purpose, white
TYPICALAPPLICATIONS
• Coldwaterservices
• Undergroundpipework,includingcontaminatedground
• Pipeworkbehindplaster
DESIgN,INSTALLATIONANDUSE
all products should be designed, installed and used in accordance with appropriate specifications or codes ofpractice(e.g.BS6700)and/orYorkshireCopperTubetechnical recommendations.
BS EN 1057
FM 00450
# Based on tube in the supplied hardnessAllcoveringsmadefromLDPEexceptproductsmarked++,whicharePVC
Kuterlex-Coilrange
BSEN13349/BSEN1057Annealed(R220)
Size ODxWall
CoveringThickness available colours and lengths
nominal Tube Weight
nominal CoveringWeight
MaximumWorkingPressureupto65°C
Bore Capacity
Coilsperpallet
(mm) (mm) 10m 20m 25m 50m (Kg/m) (Kg/m) (bar) # (l/m)
8x0.6 1.0++ 0.124 0.04 66 0.03640
30
10 x 0.7 1.0++ 0.182 0.07 62 0.058
50
40
20
15x1.0 1.0 0.391 0.05 67 0.133 35
22x1.2 1.0 0.698 0.07 57 0.302 25
Kuterlex - Straight tube range
BSEN13349/BSEN105715-28mmHalf-hard(R250),35-76.1mmHard(R290)
Size ODxWall
CoveringThickness
available colours and lengths
nominal Tube Weight
nominal CoveringWeight
MaximumWorkingPressure
up to 65°C
Bore Capacity
Tubes per
inner bundle
Tubes per master bundle
(mm) (mm) 3m 5.8m 6m (Kg/m) (Kg/m) (bar) # (l/m) 5.8m/3m/6m15x1.0 1.0 0.391 0.05 87 0.133 10 100
15x0.7 1.0 0.280 0.05 58 0.145 10 100/240/240
22x0.9 1.0 0.531 0.07 51 0.321 10 100/150/150
22x1.2 1.0 0.698 0.07 69 0.302 10 100
28x0.9 1.0 0.682 0.08 40 0.539 5 50/90/90
28x1.2 1.0 0.899 0.08 55 0.515 5 100/150
35x1.2 1.5 1.134 0.16 51 0.835 5 50
35x1.5 1.5 1.405 0.16 65 0.804 5 50/100
42x1.2 1.5 1.369 0.19 42 1.232 5 50
42x1.5 1.5 1.699 0.19 54 1.195 5 50/75
54x1.2 1.5 1.772 0.24 33 2.091 3 30
54x2.0 1.5 2.908 0.24 56 1.964 3 30/45
66.7x1.2 2.0 2.198 0.40 26 3.248 1 10
76.1x1.5 2.0 3.129 0.45 29 4.197 1 10
Kuterlex Plus Plastic Coated Copper Tube to BS EN 13349 / BS EN 1057
KuterlexPluscoppertubeissheathedinacontinuouscoverthathasairchannelsontheinternalsurface.KuterlexPlusis primarily designed to give the tube enhanced protection from external attack. In addition, the cover creates a thermal barrier which reduces heat loss from buried tube and condensation on exposed cold pipework. It has an insulation factor of 0.29W/m/K.
STandard feaTUreS
• Cu-DHPgradecopper
• ManufacturedinaccordancewithBSEN13349(specification for covered copper tube)
• CoppertubetoBSEN1057
• BSiKitemarklicensed(coppertube)
• 25yearguaranteeagainstproductfailuredirectlyattributable to a manufacturing defect
• Straightlengthsavailablein5.8mlengthsforcontainerloads to export markets
BenefITS
• Reducesinstallationtime
• Protectsthecoppertubeagainstaggressivematerials
• Protectsthecoppertubeagainstaccidentaldamage and abrasion
• Plasticcoveringwithstandswaterservicetemperaturesupto95°C
• Coveringremainsflexibledownto-60°C
• Reducescondensationonexposedpipework (see graph 1)
• Reducessurfacetemperatureofthetube(seegraph2),thereby minimising the risk of burns or scalding
• Reducesnoiselevelinexposedpipework
• Removestheneedtopaintexposedpipework
TYPICALAPPLICATIONS
• Hotwatersystems
• Undergroundpipework,includingcontaminatedground
• Pipeworkinstalledinconcrete
• Humidatmospheres
DESIgN,INSTALLATIONANDUSE
all products should be designed, installed and used in accordance with appropriate specifications or codes of practice(e.g.BS6700)and/orYorkshireCopperTubetechnical recommendations.
BS EN 1057
FM 00450
graph2:Surfacetemperatureofplain andKuterluxPlustubesinair
Graph 1: Temperature at which condensation occurs onplainandKuterlexPlustubes
KuterlexPlus-Straighttuberange
BSEN13349/BSEN105715-28mmHalf-hard(R250),35-54mmHard(R290)
Size ODxWall
CoveringThickness
available colours and lengths
nominal Tube Weight
nominal CoveringWeight
MaximumWorking
Pressureupto65°C
Bore Capacity
Tubes per inner bundle
Tubes per master bundle
(mm) (mm) 5.8m (Kg/m) (Kg/m) (bar) # (l/m) 5.8m15x0.7 2.0 0.280 0.07 58 0.145 10 100
22x0.9 2.0 0.531 0.13 51 0.321 10 100
KuterlexPlus-Coilrange
BSEN13349/BSEN1057Annealed(R220)
Size ODxWall
CoveringThickness
available colours and lengths
nominal Tube Weight
nominal CoveringWeight
MaximumWorking
Pressureupto65°C
Bore Capacity Coilsperpallet
(mm) (mm) 25m (Kg/m) (Kg/m) (bar) # (l/m)8x0.6 1.6++ 0.124 0.06 66 0.036 40
10 x 0.7 1.6++ 0.182 0.07 62 0.058 40
15x1.0 2.0 0.391 0.07 67 0.133 30
22x1.2 2.0 0.698 0.11 57 0.302 20
# Based on tube in the supplied hardnessAllcoveringsmadefromLDPEexceptproductsmarked++,whicharePVC
Jointing Guide For Kuterlex and Kuterlex PlusCapillary Jointing
6.Clean tube and fitting with a suitable abrasive pad.
7. apply flux. 8.Connecttubeandfitting.
10.Heatwithblowlamp.9.Wrapexposedplastic with a damp cloth.
11.Whencooledremovedamp cloth and re-position plastic.
12.Securewithtape.
13.Thefinishedjoint. 14. exposed ends should be sealed with tape.
1.Makecircularincision in plastic cover.
2.Removethecutplasticfrom the end of the tube.
3.Maketheincisioninplasticalong tube.
5.Securethesplicedplasticcover with tape.
4.Peelbacktheplastic cover carefully.
HEAT-FREEJOINTINg
Whenusingheatfreefittings,sufficientplasticcovershouldberemovedtoallowinsertionofthetubeuptothetubestop(seepictures
1&2above).
Whenthejointiscomplete,theexposedpipeworkmustbecompletelyprotectedbyspirallywrappingthejointedregionwithwaterproof,adhesive,
Kuterlex Gas Plastic Coated Copper Tube Straights and Coils to BS EN 13349/1057
Kuterlex gas products are copper coils and straight lengths coated with a protective yellow seamless plastic cover which safeguards against external corrosion and provides service identification. The Kuterlex plastic cover eliminates laborious wrapping operations and is colour coded to identify the services carried as gases in accordance with local authority specifications and BS 1710: 1984, “Specification for identification of pipelines and services”.
STandard feaTUreS
•Yellowcolouredplasticcoveringforgasserviceidentification
•Cu-DHPgradecopper
•CoppertubeBSiKitemarkapproved
•CoilssuppliedinR220(annealed)conditionandstraightsinR250(halfhard)condition
•Suitableforcoldbendingandforming
•Coilssuppliedin25mcoilsandstraightsavailablein3mand6mlengths
BenefITS
•Avoidsneedtowraporidentifytubeonsite,therebyreducing installation time
•Idealforlongpipe-runswithoutjoints
•Coveringhelpscushionthecoppertubeagainstaccidental impact damage
•Coveringprotectsthecoppertubeagainstaggressivematerials, allowing installation underground or behind plaster
•Coveringremainsflexibledownto-60ºC
DESIgN,INSTALLATIONANDUSE
all products should be designed, installed and used in accordance with appropriate specifications or codes of practice(e.g.BS6700)and/orYorkshireCopperTubetechnical recommendations.
Kuterlex Gas
BSEN13349/BSEN1057-CoilsR220(Annealed)StraightsR250(Halfhard)
Size ODxWall
PlasticCoveringThickness
Standard available colours
and lengths
nominal Tube Weight
nominal CoveringWeight
MaximumWorking
Pressureupto65°C
Bore Capacity
Coilsper
pallet
Tubes per
bundle
(mm) (mm) 3m/6mstraights
25mcoils (Kg/m) (Kg/m) (bar) # (l/m)
10 x 0.7 1.6 0.182 0.07 62 0.058 4015x0.7 1.0 0.280 0.5 58 0.145 240
15x1.0 2.0 0.391 0.12 67 0.133 3022x0.9 1.0 0.531 0.7 51 0.321 15022x1.2 2.0 0.698 0.16 57 0.302 2028x0.9 1.0 0.632 0.8 40 0.539 90
# all pressures quoted in the above table are based on tube in the supplied hardness