Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

14
Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise

Transcript of Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Page 1: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Kurt RobinsonMoussa KanteAlex Gardtner

Movie Theater Noise

Page 2: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

The Hearing ProcessComponents of the

earOuter Ear

Pinna Ear Canal

Middle EarEardrumMalleus, Incus, Stapes

Inner EarCochleaCochlear Nerve

Page 3: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

The Hearing ProcessEnergy Conversions of

Sound

Acoustical Energy

Mechanical Energy

Hydraulic Energy

Chemical Energy

Electrical Energy

Page 4: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Aims of StudyIdentify noise levels in theatresCompare noise levels to OSHA guidelinesDiscuss with viewers if they were adversely

affected by the noise

Page 5: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Description of TaskPurchased 4 Individual C batteriesSnuck Octave Band Analyzer on the inside

of our coatsSat in multiple sections of the Movie

TheatreHeld the Octave Band Analyzer in our lapsHad the Analyzer on Db(A)Paid close attention to the Analyzer at all

times

Page 6: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Technical EquipmentOctave Band Analyzer

o Features whole and 1/3-octave real-time spectral analysis using digital Butterworth bandpass filters, as recommended by ANSI Standards

o Supports calibrated sound level measurements in whole and 1/3-octave bands, including Lp, Lp_max, Lp_peak, and Leq

o Flat, A, and C frequency weightingo Fast, Slow, and Impulse time weightingo Supports non-acoustic signals with units other

than Pascalso Captures current spectrum for later review

Page 7: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Table G-16 TABLE G-16 - PERMISSIBLE NOISE EXPOSURES (1) ______________________________________________________________ | Duration per day, hours | Sound level dBA slow response ____________________________|_________________________________ | 8...........................| 90 6...........................| 92 4...........................| 95 3...........................| 97 2...........................| 100 1 1/2 ......................| 102 1...........................| 105 1/2 ........................| 110 1/4 or less................| 115 ____________________________|________________________________

Page 8: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Movies

Page 9: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Quantitative FindingsBank Job – Action/Suspense

Peak – 88.7 dBA Mean – 72 – 76 dBA

“21” – DramaPeak – 84.7 dBAMean – 65 – 70 dBA

Page 10: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Qualitative DataSpeaker ArrangementNoise Readings from Multiple AreasInterviews with patronsSeating Arrangement

Page 11: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Types of Seating

Page 12: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

IMAX 3D TheaterMuseum of Discovery and Science IMAX 3D

Theater

Several Sound Complaints

Possible Different Speaker Arrangement

Page 13: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

Intervention Methods

Not much that can be done.

Speak to a manager.

Call theater company and file a complaint.

Page 14: Kurt Robinson Moussa Kante Alex Gardtner Movie Theater Noise.

SummaryOnly one reading exceeded action level.No readings exceeded exposure limit.Very subjective study

Different theaters by different companiesDifferent policiesDifferent genres of movies

Is this an outdated study?Different time era