KOHA SWIVEL BASIN MIXER INSTALLATION GUIDE...436600 Issue D KOHA SWIVEL BASIN MIXER INSTALLATION...

2
Issue D 436600 KOHA SWIVEL BASIN MIXER INSTALLATION GUIDE TECHNICAL SPECIFICATIONS Operating Pressure: Min 35 kPa, Max 1000 kPa. Recommended 35 kPa - 500 kPa. Recommended installation of a pressure limiting valve if supply exceeds 500kPa. Operating Temperature: Hot: Max 80°C. Cold: Min 5°C. NB: New Zealand Building Code Clause G12 - Water Supplies specifies all outlets used primarily for personal hygiene shall deliver water at a safe temperature. Inlet Connections: All ½" BSP. Methven warrants this product against manufacturing defects and that it is suitable for use under the operating conditions specified in this instruction sheet. For your warranty please refer to www.methven.com or call Customer Service New Zealand 0800 804 222 Australia 1300 638 483 USA 1800 975 5409 UK 0800 195 1602

Transcript of KOHA SWIVEL BASIN MIXER INSTALLATION GUIDE...436600 Issue D KOHA SWIVEL BASIN MIXER INSTALLATION...

Page 1: KOHA SWIVEL BASIN MIXER INSTALLATION GUIDE...436600 Issue D KOHA SWIVEL BASIN MIXER INSTALLATION GUIDE TECHNICAL SPECIFICATIONS Operating Pressure: Min 35 kPa, Max 1000 kPa. Recommended

Issue D436600

KOHA SWIVEL BASIN MIXER INSTALLATION GUIDETECHNICAL SPECIFICATIONS

Operating Pressure:Min 35 kPa, Max 1000 kPa. Recommended 35 kPa - 500 kPa.Recommended installation of a pressure limiting valve if supply exceeds 500kPa.Operating Temperature:Hot: Max 80°C.Cold: Min 5°C.NB: New Zealand Building Code Clause G12 - Water Supplies specifies all outlets used primarily for personal hygiene shall deliver water at a safe temperature.Inlet Connections:All ½" BSP.

Methven warrants this product against manufacturing defects and that it is suitable for use under the operating conditions specified in this instruction sheet. For your warranty please refer to www.methven.com or call Customer Service

New Zealand0800 804 222

Australia1300 638 483

USA1800 975 5409

UK 0800 195 1602

Page 2: KOHA SWIVEL BASIN MIXER INSTALLATION GUIDE...436600 Issue D KOHA SWIVEL BASIN MIXER INSTALLATION GUIDE TECHNICAL SPECIFICATIONS Operating Pressure: Min 35 kPa, Max 1000 kPa. Recommended

IMPORTANT Please read all of the instructions before installation

This mixer is designed for equal and unequal pressure systems.

This mixer is not recommended for use in uncontrolled heating systems such as wet-backs or solar heating units.

NOTE: Base ring use is optional and should be used when required to ensure a seal is achieved between the tap and basin. If fitting base ring please remove the o-ring from the base of the tap body.

All pipework must be thoroughly flushed prior to the installation of the mixer. In-line filters must be fitted on both hot and cold supplies to prevent foreign particles damaging the ceramic cartridge.

CORRECT

INCORRECT

DO NOT STRETCH OR TWIST HOSES

R35mm M

in

20m

m

ColdDO NOT CRUSH HOSE OR SWAGED ENDS

Equal Low Pressure Installations

Remove flow restrictor with suitable blunt instrument

Cold

Swivel Aerator

O-ring (remove if fitting base ring)

Mounting stud

Mounting gasket

Mounting plate

Mounting nut

Flexible inlet hose: cold hot

Max 40mm

Ø 35mm

Hot

Equal Low Pressure and Unequal Pressure Installations

Remove flow restricted swivel aerator (yellow) using cache key. Replace with un-restricted (blue) swivel aerator.