KnaufDanoline Catalogue 2012 UK
-
Upload
macovei-alexandru -
Category
Documents
-
view
213 -
download
0
description
Transcript of KnaufDanoline Catalogue 2012 UK
KNA
UF
DA
NO
LIN
E C
ATA
LOG
UE
05
/20
12
3
When choosing Knauf Danoline, you choose: • Competenceandexperience• Sustainableandenvironmentally
responsiblematerials• Excellentindoorcomfortforthe
occupantsofthebuilding• Alargevarietyoftechnicaland
designsolutionsforceilingsandwalls
50Welcometo yearsofquality&experience YOURWAYTOINDOORCOMFORTHeadquarteredinDenmarkKnaufDanolinedevelops,manufacturesandmarketsacoustic ceilingandwallmaterialsbasedonhighgradeglassfiber reinforcedgypsum.With the several decades long presence in the construction industry,KnaufDanolineisabletoofferexpertise,guidanceandtechnicalsolutionstomeetyourspecificrequirements.
Theextensiverangeofhighqualityproductsincludes• DemountableT-gridceilings–abroadselectionofacousticceilingstileswith
differentexpressions,designopportunitiesandacousticprofiles• Self-supportingceilings–specialpurposeacousticceilingsforcorridorsand
narrowrooms• Non-demountableceilings–avarietyofacousticpanelsforscrew-fixingwith
differentdesignexpressions,installationmethodsandacousticprofiles• Walllinings–awidechoiceofacousticpanelsforwallmounting,withthe
possibilityofcompleteintegrationwithexistingwallconstruction• Specialpurpose–hygieneceiling,wallpanelsforcinemas,impactresistant
liningsforsportshalls• Curvedandmitredelements –designelements fororganic shapesorwell
definededges
Knauf Danoline is always at your disposal for a dialogue about customisedsolutionsaccordingtoyourwishes.
KnaufDanolineispartoftheinternationalKnaufGroup-aworldwideproviderofconstructionmaterials.Throughownsalesorganisationsandalargenetworkofdistributionpartners,KnaufDanolineisrepresentedinmorethan40countries.ForyourlocalKnaufDanolinerepresentative,pleasegotoknaufdanoline.com.
KnaufDanolineproductsaretestedforindoorclimateproperties(DIM).Theyhavelowparticleemissionandindoorvalueof<10days.
KnaufDanolineisISO9001andISO14001accredited.
INTRODUCTION
4
ThenewKnaufDanolinecataloguepresentsourentireproductrangewiththemostrelevantdata.Foreachproducttherearetechnicaldetails,aninstallationguideandanaccessoriesoverview.
Fordownloadofdrawings,photosandotherdigitaldata,pleasegotoourwebsiteknaufdanoline.com.
KNAUFDANOlINECATAlOGUE2012
4
lindaAydostian,C.E.T.E.lyon,France,Vista,Tangent
IntroDuctIon 3
proDuct overvIeW 6
Demountable t-grID ceIlIngs
Unity6System 8
Vista 16
Contur 24
Belgravia 32
linear 40
Markant 48
Plaza 56
Danotile 64
self-supportIng ceIlIngs
Unity6Bridge 72
Corridor400 80
CorridorSwing 88
CorridorF30 96
non-Demountable ceIlIngs
Designpanel 104
Tectopanel 114
Contrapanel 122
Danopanel 130
Solopanel 138
Stratopanel 148
Wall lInIngs
Designpanel 158
Tectopanel 166
Contrapanel 174
Solopanel 180
Stratopanel 188
Kinopanel 196
Amfipanel 202
Adit 210
DesIgn elements
Mitex 218
Curvex 222
perforatIons
U6 228
Tangent 228
Micro 229
Quadril 229
Globe 230
Kino 230
Solo 231
Strato 231
propertIes
Acoustics 234
Airquality 235
Cleaning 235
lightreflection 236
load-bearingcapacity 237
Ambientconditions 237
Firesafety 238
Robustness 238
Environment 239
Colours 240
Warranty 241
Upkeep&maintenance 242
6
PRODUCT EDGE PERFORATION SIZE(mm) APPlICATION PAGE
UNITY6SYSTEMEdgeD
U6 600x600x12.5 MonolithiclookinconlcealedT-gridceiling;edgetoedgeperforationforcontinuousexpression
8
VISTAEdgeE/B
TangentRegula
400x1200x12.5300x1200x12.5
Demountable,suspendedceilingindoubleT-gridwithDrag‚n‘Dropfeatureforflexibileceilingandlightingdesign
16
CONTUREdgeD
GlobeQuadrilMicroTangentRegula
600x600x12.5625x625x12.5
Demountable,suspendedceilingincon-cealedT-grid
24
BElGRAVIAEdgeE
GlobeQuadrilMicroTangentRegula
600x600x12.5625x625x12.5
Demountable,suspendedceilinginrecessedT-grid
32
lINEAREdgeC
GlobeQuadrilMicroRegula
600x600x12.5 Demountable,suspendedceilinginsemi-concealedT-grid
40
MARKANTEdgeE
GlobeQuadrilMicroTangentRegula
600x600x12.5600x1200x12.5*625x625x12.5625x1250x12.5**NotwithTangent
Demountable,suspendedceilinginrecessedT-grid
48
PlAZAEdge
GlobeQuadrilMicroTangentRegula
600x600x9.5*600x600x12.5600x1200x9.5*600x1200x12.5*625x625x12.5625x1250x12.5**NotwithTangent
Demountable,suspendedceilinginvisibleT-grid
56
DANOTIlEEdgeA
Regula 600x600x6.5600x600x9.5600x1200x6.5600x1200x9.5625x625x9.5
Specialpurposehygieneceiling.Demounta-ble,suspendedceilinginvisibleT-grid
64
UNITY6BRIDGEEdgeD
U6 400x1200x12.5400x1500x12.5400x1800x12.5400x2100x12.5400x2400x12.5400xlx12.5
Demountableself-supportingceilingrequiringnohangers,forcorridorsandnarrowrooms.Easyaccesstocavity.Edgetoedgeperforati-onforcontinuousceilingexpression
72
CORRIDOR400EdgeD
GlobeQuadrilMicroTangentRegula
400x1200x12.5400x1500x12.5400x1800x12.5400x2100x12.5400x2400x12.5400xlx12.5
Demountableself-supportingceilingrequiringnohangers,forcorridorsandnarrowrooms.Easyaccesstocavity
80
CORRIDORSWINGEdgeE
GlobeQuadrilMicroRegula
600x1200x12.5600x1500x12.5600x1800x12.5
Hingedceilingpanelsforcorridorsandaccessareasinnon-demountableceilings,allowingeasyaccesstothecavityandinstallations.
88
CORRIDORF30EdgeD
GlobeQuadrilMicroRegula
300xlx100Max.length:2800mm
Demountableself-supportingceilingforcorridorsensuringeasyaccesstocavityand30minutesfireresistanceaccordingtoDIN4102-2
96
PRODUCTOVERVIEW
7-6
PRODUCT EDGE PERFORATION SIZE(mm) APPlICATION PAGE
DESIGNPANElEdgeA1/A1
GlobeQuadrilMicroTangentRegula
1200x2400x12.5900x2700x12.5900x2400x12.5**(OnlyTangentRegula)
Non-demountableceiling&wallliningFourtaperededgesforcontinuousceilingandwalldesign;Possibilityoffullintegrationwithexisitingwallconstruction
Ceiling104
Wall158
TECTOPANElEdgeB
GlobeQuadrilMicroTangentRegula
600x600x12.5300x1200x12.5400x1200x12.5600x1200x12.5*600x2400x12.5*625x625x12.5*625x1250x12.5*400x600x12.5**400x600x9.5***
Non-demountableceiling&walllining.Fil-lingofscrewholesandpaintingrequired.
*OnlyG,Q,R**OnlyG,R***OnlyR
Ceiling114
Wall166
CONTRAPANElEdgeB
GlobeRegula
600x1200x12.5600x1800x12.5600x2400x12.5
Specialpurposeimpactresistantceilingandwallliningforsportshallsandgymnasiums
Ceiling122
Wall174
DANOPANElEdgeB
GlobeQuadrilMicroTangentRegula
600x600x12.5 Non-demountableceilinglining,suppliedpre-paintedfromfactory;equippedwithhiddenfixings.Nojointfillingrequired.
130
SOlOPANElEdge:SKFFMF
SK
FF
MF
G8/18G10/23G12/25G15/30Q8/18G8/12/50G12/20/66
Forsizes,pleasegotopage140
Non-demountableceiling&wallliningwithregularperforationpattern;perforationtotheedgeleavingacompeletelyhomogenoussurface
Ceiling138
Wall180
STRATOPANElEdge:SKFF
SK
FF
G8/15/20G12/20/35
Forsizes,pleasegotopage150
Non-demountableceiling&wallliningwithrandomperforationpattern;perforationtotheedgeleavingacompeletelyhomogenoussurface
Ceiling148
Wall188
KINOPANEl Kino 600x600x12.5 Specialpurposewallliningforextraordinaryacousticregulationincinemas
196
AMFIPANEl Tangent 600x600x12.5600x900x12.5
Specialpurposewallliningforextraordinaryacousticregulationincinemas
202
ADIT
Tangent 450x2400x9.5 Specialpurposewallliningforexceptionallyquickandeasyacousticregulationinexistingrooms.Minimumdisturbanceofthedailyactivitiesintherooms.
210
8
ContinuouslookwithconcealedT-grid.Acousticgypsumceilingrequiringlowinstallationdepth.Perforationstotheedge.Unifieddemountableceilingsurface.
UNITY6SYSTEM/DEMOUNTABlET-GRIDCEIlING
9-8
unIty 6 system
Didyouknowthat…
KnaufDanolineacousticalceilingsandwallscanmeetyournationalrequirementsintermsofacoustics?
Unity6SystemVistaConturBelgravialinearMarkantPlazaDanotile
RosendalGymnasium,Denmark,Unity6System,U6
10
15 615
15
Sizes600x600x12.5mm
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
UNITY6SYSTEMDEMOUNTABlET-GRIDCEIlING
EdgeD(rebatedandgrooved)/S24Concealedgrid
U6,Ø6mm,15mmc/c,15mmtoedge
PerforationU6:11.95%
11-10
1,0
0,8
0,6
0,4
0,2
0,0
αp
Hz400020001000500250125
αp 0,60 0,70 0,65 0,60 0,600,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflection72.8%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity1/A/Noload
FireclassA2-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
ACOUSTICSunIty 6 system
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Unity6 9.2 10.1 10.7
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
Unity6System,200mmsuspension,nomineralwool αw:0,65,NRC:0,70
12
X
A B
DC E
marking and wall angles• Mark the locationof thewallangleson thewalls
and columns in relation to the required ceilingheight.
• Installthewallanglesatmax.300mmc/c.Choosethemethodof securing theangles inaccordancewiththesubstrate.
corners• Insidecorners(1):cutthecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingto the contrary is specified. Finishwith a cornercover,ifnecessary.
• Outsidecorners(2):mustalwaysbemitred.Finishwithacornercover,ifnecessary.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• The location of light fittings and ventilation unitswillhaveaninfluenceonceilinglayout.
• Install thefirstmainrunneratmax.600mmfromthewall.Theothermainrunnersshouldbeinstalledat600mmc/c.
Hangers• Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Direct hangers (2) are secured to the ceiling
using appropriate fixings in accordancewith thesubstrateandlockedtothemainrunnerwithanail.
• Install the first hanger at max. 100mm from thewall.Theotherhangersshouldbeinstalledatmax.1500mmc/c.
• If loadsfromlightfittingsetc.are tobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
600 x 600 mm moduleINSTAllATIONGUIDE
Fig.1A=Max.600mm B=Max.600mm C=Max.1500mm D=Max.100mm E=Min.63mm
Wallangle1430orshadowlinetrim1459Mainrunner850Spacerbar8260013
Adjustablehanger(typedependsoninstallationdepth)
legend:
13-12
Installation• Alwayswear clean cotton gloveswhen handling
ceilingelements.• Install the elements by lifting the “male” side up
acrosstheonemainrunner,thenpushthe“female”sideintopositionintheadjacentmainrunnerandlowerthe“male”sideonthemainrunner.
• Checkthatallmetalclipsarerestingonthemainrunner.
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.• Ifmetalclipsare installed in theplacewhere the
elementistobecut,theymustberemovedfirst.• Gripthemetalwithapairofpliersandtwistitoff
gently.• A new metal clip can be pressed into position
with a clip mounting tool available from KnaufDanoline.
fixtures and fittings• With smallerunits (ofup to3kg)a reinforcement
panelofsufficientstrengthcanbeinstalledbehindtheUnity6Systemelement.
• The reinforcement panel must extend all theway into themain runners, so that theweight istransferredtothem.
• Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeused
• Unitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
spacer bars• Align thefirstmain runneralongoneof thewalls
andsecureitwiththehelpofadjustedspacerbarsscrewedintothewall(1).
• Installtheotherspacerbars(2).• NB!Whenusing50mmdirecthangers,thespacer
barsmustbeinstalledatthesametimeasthemainrunners (or it will not be possible to install thespacerbars).
adjustment• Checkthatallprofilesarecorrectlyalignedwhen
theentiresuspensiongridhasbeeninstalled.• Adjust the hangers so that they are tant and the
ceilingsurfaceislevel.
main runners• Install themain runners parallel to each other so
thattheslotsareatrightanglestoeachother.• Join the main runners longitudinally and lock
them in position by bending the end couplingsbackwards.
• Adjustthelengthsoftheprofileswithplateshears,ahacksaworacross-cutsawwithaspecialblade.
• Makesurethereisahangerbetweentheendjointsofthemainrunnersandthefirebreak.
unIty 6 system
14
DETAIlS
Spacerbar
Spacerbar
Unity6System
Hanger
Mainrunner
Wallangle
Shadowlinetrim
OR
Unity6Systemingridsystem850(S24)directtowall
Unity6Systemingridsystem850(S24)withfixedfriezeon650system
Crosstee650system
Tectopanelasfixedfrieze
Tectopanelasfixedfrieze
Unity6System
Hanger
Mainrunner
Wallprofile
PlasterboardEdgetrimKS13
OR
15-14
unIty 6 system
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
Mainrunner 1366 85030 24x3600x38
Crosstee 30813082
5642206956442069
35x600x3835x1200x38
Spacerbar 1481 8260013 600
Wallangle 1455 1438 19x3050x32
Wallangle 1910 1430 20x3050x40
Shadowlinetrim 1457 1459 12+19x3050x34
Outsidecornerforwallangle
31073108
13341332
for24mmWallanglefor19mmWallangle
Insidecornerforwallangle
31093110
13481346
for24mmWallanglefor19mmWallangle
Wallprofile 3083 511069 30x3050x40.5
Directhanger337633773375
21.521.821.1
5080100
Pinfordirecthanger 11882 - -
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
Fixingtoolforclips 3372 - -
16
FlexibleacousticceilingsolutionwithDrag‚n‘Dropfunctionforadaptableplacementofceilingtilesandlightfixtures.InstalledindoubleT-gridrequiringnocrossrunners.Easyaccesstoinstallations.Nocrossrunners.
VISTA/DEMOUNTABlET-GRIDCEIlING
17-16
Didyouknowthat…
gypsum(CaSO4+2H2O)isanaturalmaterialthatisalsosyntheticallyproducedinareactionoflimestoneandfluegassesthatdecreasetheSO2emissionsfrompowerstationstherebyreducingacidprecipitation?
vIsta
Unity6SystemVistaConturBelgravialinearMarkantPlazaDanotile
NouvellesCliniquesNantaises,France,VistaTangent
18
Sizes400x1200x12.5mm300x1200x12.5mm
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
VISTADEMOUNTABlET-GRIDCEIlING
PerforationTangent(T):21.3%
AlsoavailableasRegula.Otherperforationpatternsmanufacturedtoorder.
EdgeElengthwise/Bcrosswise(tegular/bevellededge)/S24Recessedgridlengthwise/Nogridcrosswise
Tangent,4x14mm,10/20mmc/c
19-18
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α
α
0,65 0,80 0,75 0,75 0,750,35
0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionTangent:70.9%Regula:82.6%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity1/A/Noload
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:B-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
vIsta
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Tangent 8.2 9.1 9.8
Regula 9.0 9.9 10.6
Certificates• FDESlCADeclaration
• DanishIndoorClimatelabelling
• DeclarationofConformity(EN14190)
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Tangent,200mmsuspension,nomineralwool αw:0.80,NRC:0.75
Regula,200mmsuspension,nomineralwool αw:0.10,NRC:0.05
20
GF
JI
HCD
E
AB
X
primary runners• Install the runnerswith the helpof hangers.Note
thatthelocationoflightfittingsandventilationunitswillhaveaninfluenceonceilinglayout.
• Theloweredgeof theprimaryrunnermustbe48mmhigherthantheheightofthefinishedceiling.
• Adjust the height of the primary runners beforeinstallingthesecondaryrunners.
marking and shadow line trim• Mark the locationof the shadow line trimon the
walls and columns in relation to the requiredceilingheight.
• Installtheshadowlinetrimsatmax.300mmc/c.Choose the method of securing the profiles inaccordancewiththesubstrate.
corners• Insidecorners(1):cut thecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingtothecontraryisspecified.
• Outsidecorners(2):mustalwaysbemitred.
Hangers• Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Direct hangers (2) are secured to the ceiling
using appropriate fixings in accordancewith thesubstrateandlockedtothemainrunnerwithanail.
• Install the first hanger atmax. 200mm from thewall.Theotherhangersshouldbeinstalledatmax.1200mmc/c.
• If loads fromlightfittingsetc.are tobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
A=Max.200mm B=Max.1200mmC=Max.400mm D=Max.400mmE=Max.2400mm F=Max.200mmG=Max.1200mm H=Max.1200mmI=Min.100mm J=Min.100mm
Shadowlinetrim1466Mainrunner85030Spacerbar8260013
Adjustablehanger(typedependsoninstallationdepth)
DGClips
legend:
INSTAllATIONGUIDE
Fig.1
400 x 1200 mm module
21-20
vIsta
spacer bars• Alignthefirstprimaryrunneralongonewalland
secure it with the help of adapted spacer bars,whichmustbescrewedtothewall(1).
• Installtheremainingspacerbars(2).• lock the secondary runner in position by gently
pullingthemdown.
Installation• Alwayswearcleancottongloveswhenhandling
ceilingelements.• Install the elements by lifting one side of the tile
across theflangeof the secondary runner, liftingtheoppositesideandpullingitbacksothatthetileisrestingonitstoplip.
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.• It is important to cut the tiles in the first and last
rowspreciselysothattheyaresecurelypositionedinthesystem.
Dg clips• Slide the number of clips necessary over the
secondaryrunner.
secondary runners• Press the DG clip up around the flanges on the
primaryrunner.• Thesecondaryrunnercanthenbeadjustedinboth
directions.
layout• Installthesecondaryrunnersparalleltoeachother.
fixtures and fittings• With smallerunits (ofup to3kg)a reinforcement
panelofsufficientstrengthcanbeinstalledbehindtheVistaelement.
• The reinforcement panel must extend all theway into themain runners, so that theweight istransferredtothem.
• Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeused.
• Unitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
22
DETAIlS
Vistaindoublegridsystem(S24)directtowall
Vistaindoublegridsystem(S24)directtowall
Primarymainrunner
Primarymainrunner
Spacerbar
Spacerbar
Secondarymainrunner Crosstee35mm
Secondarymainrunner
Shadowlinetrim
Wallprofile
6.5mmTectopanel
DGclip
DGclip
Hanger
Primarymainrunner
Primarymainrunner
Spacerbarfixedtowall
Spacerbar
Spacerbar
Secondarymainrunner
Secondarymainrunner
Shadowlinetrim
DGclip
DGclip
Hanger
Hanger
23-22
vIsta
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
Mainrunner 1366 85030 24x3600x38
Crosstee 30813082
5642206956442069
35x600x3835x1200x38
Spacerbar 13162 8269913-04 l:400
Spacerbar 1879 8269913-03 l:300
DG-clips 12978 - -
Shadowlinetrim 3813 1466 15+15x3050x8+25
Wallprofile 3083 511069 30x3050x40.5
Directhanger337633773375
21.521.821.1
5080100
Pinfordirecthanger 11882 - -
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
24
ElegantunifiedlookwithnovisibleT-grid.Demountableceilingrequiringlowinstallationdepth.Perfectlookforcombinationwithperforatedwalllinings.Fixedfriezepossibilitiestoprovideanelegantconnectionbetweenceilingandwall.
CONTUR/DEMOUNTABlET-GRIDCEIlING
25-24
Didyouknowthat…
itispossibletomakeV-cutsingypsumboardssoyoucanmitretheboardstocreatesharpangles?
contur
Unity6SystemVistaConturBelgravialinearMarkantPlazaDanotile
AndreassonArkitektkontorGöteborg,RestaurantAluddenlerum,Sweden,Contur,M1
26
CONTURDEMOUNTABlET-GRIDCEIlING
Sizes600x600x12.5mm625x625x12.5mm
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
PerforationGlobe:10.2%Quadril:13%Micro:10.2%Tangent:19.7%
AlsoavailableasRegula.Otherperforationpatternsaremanufacturedtoorder.
EdgeD(rebatedandgrooved)/S24Concealedgrid
Globe,Ø6mm,15mmc/c
Quadril,12x12mm,30mmc/c
Micro,3x3mm,8.3mmc/c
Tangent,4x14mm,10/20mmc/c
27-26
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,80 0,65 0,55 0,450,45
α 0,60 0,70 0,60 0,55 0,450,45
α 0,55 0,65 0,60 0,60 0,550,40
α
α
0,65 0,70 0,70 0,70 0,800,35
0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:72.8%Quadril:75.1%Micro:72.1%Tangent:70.9%Regula:82.6%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity1/A/Noload
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:B-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
contur
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Globe 9.2 10.1 10.7
Quadril 9.1 9.9 10.6
Micro 9.2 10.0 10.6
Tangent 9.1 9.9 10.6
Regula 9.9 10.8 11.4
Certificates• FDESlCADeclaration
• DanishIndoorClimatelabelling
• DeclarationofConformity(EN14190)
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,200mmsuspension,nomineralwool αw:0.60,NRC:0.65Quadril,200mmsuspension,nomineralwool αw:0.60,NRC:0.65Micro,200mmsuspension,nomineralwool αw:0.65,NRC:0.60Tangent,200mmsuspension,nomineralwool αw:0.70,NRC:0.70Regula,200mmsuspension,nomineralwool αw:0.10,NRC:0.05
28
X
A B
E
DC
marking and wall angles• Mark the locationof thewallangleson thewalls
and columns in relation to the required ceilingheight.
• Installthewallanglesatmax.300mmc/c.Choosethefixingsinaccordancewiththesubstrate.
corners• Insidecorners(1):cut thecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingto the contrary is specified. Finish with a cornercover,ifnecessary.
• Outsidecorners(2):mustalwaysbemitred.Finishwithacornercoverifnecessary.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• The location of light fittings and ventilation unitswillhaveaninfluenceonceilinglayout.
• Install thefirstmainrunneratmax.600mmfromthewall.Theothermainrunnersshouldbeinstalledat600mmc/c(basedonmodule600).
Hangers• Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Direct hangers (2) are secured to the ceiling
using appropriate fixings in accordancewith thesubstrateandlockedtothemainrunnerwithanail.
• Install the first hanger at max.100 mm from thewall.Theotherhangersshouldbeinstalledatmax.1500mmc/c.
• If loads fromlightfittingsetc.are tobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
Wallangle1438orshadowlinetrim1459Mainrunner85030Spacerbar8260013
Adjustablehanger(typedependsoninstallationdepth)
legend:
A=Max.600mm B=600mmC=Max.1500mmD=Max.100mmE=Min.63mm
INSTAllATIONGUIDE
Fig.1
600 x 600 mm module
29-28
cutting and finishing• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.• Ifmetalclipsare installed in theplacewhere the
elementistobecut,theymustberemovedfirst.• Gripthemetalwithapairofpliersandtwistitoff
gently.• Anewmetalclipcanbepressedintopositionwith
aclipmoutingtoolavailablefromKnaufDanoline.
fixtures and fittings• Withsmallerunits (ofup to3kg)areinforcement
panelofsufficientstrengthcanbeinstalledbehindtheConturelement.
• The reinforcement panel must extend all theway into themain runners, so that theweight istransferredtothem.
• Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeused.
• Unitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
Installation• Alwayswear clean cotton gloveswhen handling
ceilingelements.• Install the elements by lifting the “male” side up
acrosstheonemainrunner,thenpushthe“female”sideintopositionontheopposingmainrunnerandlowerthe“male”sideonthefirstmainrunner.
• Checkthatallmetalclipsarerestingonthemainrunner.
adjustment• Check that all profiles are at correctly aligned
whentheentiresuspensiongridhasbeeninstalled.• Adjust the hangers so that they are tant and the
ceilingsurfaceislevel.
spacer bars• Alignthefirstmainrunneralongoneofthewalls
and secure it with the help of adjusted spacerbarsscrewedintothewall(1).
• Installtheotherspacerbars(2).• NB! When using 50 mm direct hangers, the
spacer bars must be installed at the same timeas themainrunners(or itwillnotbepossible toinstallthespacerbars).
main runners• Install themain runnersparallel to eachother so
thattheslotsaredirectlyoppositeeachother.• Join the main runners longitudinally and lock
them in position by bending the end couplingsbackwards.
• Adjustthelengthsoftheprofileswithplateshears,ahacksaworacross-cutsawwithaspecialblade.
• Makesurethereisahangerbetweentheendjointsofthemainrunnersandthefirebreak.
contur
30
DETAIlS
Conturingridsystem850(S24)directtowall
Spacerbar
Spacerbar
Unity6System
Hanger
Mainrunner
Wallangle
Shadowlinetrim
OR
Conturingridsystem850(S24)withfixedfriezeon650system
Crosstee650system
Tectopanelasfixedfrieze
TectopanelasfixedfriezeUnity6System
Hanger
Mainrunner
Wallprofile
PlasterboardEdgetrim
OR
31-30
contur
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
Mainrunner 1366 85030 24x3600x38
Crosstee 30813082
5642206956442069
35x600x3835x1200x38
Spacerbar 1481 8260013 600
Wallangle 1455 1438 19x3050x32
Wallangle 1910 1430 20x3050x40
Shadowlinetrim 1457 1459 12+19x3050x34
Outsidecornerforwallangle
31073108
13341332
for24mmWallanglefor19mmWallangle
Insidecornerforwallangle
31093110
13481346
for24mmWallanglefor19mmWallangle
Wallprofile 3083 511069 30x3050x40.5
Directhanger337633773375
21.521.821.1
5080100
Pinfordirecthanger 11882 - -
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
Fixingtoolforclips 3372 - -
32
Recessedgridlookwithdiscreetshading.Classicandhighlyrobustacousticceiling.Exceptionallyeasytoinstallanddemount.
BElGRAVIA/DEMOUNTABlET-GRIDCEIlING
33-32
Didyouknowthat…
innature,whenlimestoneandsmokeparticlesfromvolcanoscomeincontactwithwater,thecrystalCaSO4+H2Oisproduced?TheBeerenbergvolcanoonJanMeyenisthereasonforlargequantitiesofnaturalgypsumfoundaroundtheworldtoday.
belgravIa
Unity6SystemVistaConturBelgravialinearMarkantPlazaDanotile
ArchitectFrançoisBenedini,ArdeaHQ,France,Belgravia,Tangent
34
Sizes:600x600x12.5mm625x625x12.5mm
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
BElGRAVIADEMOUNTABlET-GRIDCEIlING
Perforation:Globe:10.2%Quadril:13%Micro:10.2%Tangent:21.3%
AlsoavailableasRegula.Otherperforationpatternsaremanufacturedtoorder.
EdgeE(tegular)/S15orS24orUltralineRecessedgrid
S15/S24
Ultraline
Globe,Ø6mm,15mmc/c
Quadril,12x12mm,30mmc/c
Micro,3x3mm,8.3mmc/c
Tangent,4x14mm,10/20mmc/c
35-34
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,80 0,65 0,55 0,450,45
α 0,60 0.70 0,65 0,60 0,450,45
α 0,55 0.65 0,60 0,60 0,550,40
α 0,65 0.80 0,75 0,75 0,750,45
α 0,20 0.10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:72.8%Quadril:75.1%Micro:72.1%Tangent:70.9%Regula:82.6%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity1/A/Noload
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:B-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
belgravIa
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Globe 8.2 9.0 9.7
Quadril 8.1 8.9 9.6
Micro 8.2 9.0 9.7
Tangent 8.1 8.9 9.6
Regula 8.9 9.7 10.3
Certificates• FDESlCADeclaration
• DanishIndoorClimatelabelling
• DeclarationofConformity(EN14190)
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,200mmsuspension,nomineralwool αw:0.60,NRC:0.65Quadril,200mmsuspension,nomineralwool αw:0.60,NRC:0.65
Micro,200mmsuspension,nomineralwool αw:0.65,NRC:0.60
Tangent,200mmsuspension,nomineralwool αw:0.80,NRC:0.75
Regula,200mmsuspension,nomineralwool αw:0.10,NRC:0.05
36
X
AB
C D
E
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• The location of light fittings and ventilation unitswillhaveaninfluenceonceilinglayout.
• Thefirstmainrunnerisinstalledatmax.600mmfrom thewall. The other main runners should beinstalledat600/1200mmc/c.
Hangers• Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Direct hangers (2) are secured to the ceiling
usingappropriate fixings in accordancewith thesubstrateandlockedtothemainrunnerwithanail.
• Install the first hanger atmax.400mm from thewall.Theotherhangersshouldbeinstalledatmax.1200mmc/c.
• If loadsfromlightfittingsetc.aretobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
marking and wall angles• Mark the locationof thewallangleson thewalls
and columns in relation to the required ceilingheight.
• Fixthewallanglesatmax.300mmc/c.Choosethefixingsinaccordancewiththesubstrate.
corners• Insidecorners(1):cutthecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingtothecontraryisspecified.
• Outsidecorners(2):mustalwaysbemitred.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
Wallangle1420orshadowlinetrim1466Mainrunner85030or7500Crosstee854or7514Crosstee852or7512Adjustablehanger(typedependsoninstallationdepth)
legend:
A=Max.400mm B=Max.1200mm C=Max.600mm D=600/1200mm E=Min.120mm
INSTAllATIONGUIDE
Fig.1
600 x 600 mm module
37-36
adjustment• Checkthatallprofilesarecorrectlyalignedwhen
theentiresuspensiongridhasbeeninstalled.• Adjust thehangers so that theyare tantand the
ceilingsurfaceislevel.
cutting• Cuttheelementstosizefromthefrontfacewitha
fine-toothedsaw.
fixtures and fittings• Forsizesupto625x625notinTangentperforation,
unitsofupto3kgcanbeinstalleddirectlyintothepanelwithoutreinforcement.
• ForlargermodulesizesandallsizeswithTangentperforation a reinforcement panel of sufficientstrength can be installed behind the Belgraviaelement.
• The reinforcement panel must extend all theway into themain runners, so that theweight istransferredtothem.
• Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeused.
• Unitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
Installation• Always wear clean cotton gloves when handling
ceilingelements.• Installtheelementsbytiltingthemupbetweenthe
T-profiles.
cross profiles• Push the snap-in tongue into the sloton themain
runnerusinglightdownwardpressure.• If there is a crossprofileon theopposite sideof
themainrunner,thenewonemustbeontherighthandsideoftheonealreadyinplace.
• If a cross profile is not to be continued into theadjacentmodule,thesnap-intonguemustbesplitandbentflat.
main runners• Install themain runnersparallel to eachother so
thattheslotsaredirectlyoppositeeachother.• Join the main runners longitudinally and lock
them in position by bending the end couplingsbackwards.
• Adjustthelengthsoftheprofileswithplateshears,ahacksaworacross-cutsawwithaspecialblade.
• Makesurethereisahangerbetweentheendjointsofthemainrunnersandthefirebreak.
belgravIa
38
DETAIlS
Belgraviaingridsystem7500(S15)or850(S24)directtowall
Belgraviaingridsystem7500(S15)or850(S24)withfixedfriezeon650system
Belgraviaingridsystem7500(S15)or850(S24)withalternativefriezesolutions
Wallprofile
Crosstee
Wallprofile
Crosstee650system
Crosstee650systemCrosstee
EdgetrimKS13Belgravia
BelgraviaWallangle
Mainrunner
Mainrunner
6.5mmTectopanel600x1200(cuttosize)
12.5plasterboardaccordingtosuppliersinstructions
Friezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
Belgraviaingridsystem7500(S15)or850(S24)withPlazafrieze
Crosstee(cuttosize) Crosstee
Shadowlinetrim Belgravia Mainrunner BelgraviaWallangle
6.5mmstriptosupportthecrosstee
Crosstee CrossteeHanger
Shadowlinetrim Plaza Mainrunner BelgraviaWallangle
Hanger
Hanger
Noniushenger
39-38
belgravIa
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
MainrunnerS24 1366 85030 24x3600x38
CrossteeS24
13741507
8523085430
24x600x3824x1200x38
MainrunnerS15 1500 750030 15x3000x38
CrossteeS15
15131515
751230751430
15x600x3815x1200x38
MainrunnerUltraline 1911 350030 14.3x3600x41
CrossteeUltraline
19121913
351230351430
14.3x600x4114.3x1200x41
Crosstee 30813082
5642206956442069
35x600x3835x1200x38
Wallangle 1455 1438 19x3050x32
Wallangle 1509 1420 24x3050x24
Shadowlinetrim 3813 1466 15+15x3050x8+25
Outsidecornerforwallangle
31073108
13341332
for24mmWallanglefor19mmWallangle
Insidecornerforwallangle
31093110
13481346
for24mmWallanglefor19mmWallangle
Wallprofile 3083 511069 30x3050x40.5
Directhanger337633773375
21.521.821.1
5080100
Pinfordirecthanger 11882 - -
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
40
Distinctivelookwithfloatingtileeffect.Acousticceilingwithlowinstallationdepth.Exceptionallyeasytoinstallanddemountgivingquickandeasyaccesstoinstallations.
lINEAR/DEMOUNTABlET-GRIDCEIlING
41-40
Didyouknowthat…
22%ofgypsum’smassiswater,whichisboundtothegypsumcrystalandensuresthefireprotectivepropertiesofgypsumboards?
lInear
Unity6SystemVistaConturBelgravialinearMarkantPlazaDanotile
KHRArchitects,ArlandaAirport,Sweden,linear,Micro
42
lINEARDEMOUNTABlET-GRIDCEIlING
Sizes600x600x12.5mm
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
PerforationGlobe:9.1%Quadril:10.2%Micro:10.2%
AlsoavailableasRegula.Otherperforationpatternsaremanufacturedtoorder.
EdgeC(groovededge)/S24Semi-concealedgrid
Globe,Ø6mm,15mmc/c
Quadril,12x12mm,30mmc/c
Micro,3x3mm,8.3mmc/c
43-42
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,60 0,70 0,60 0,50 0,400,40
α 0,50 0,60 0,50 0,45 0,350,40
α
α
0,55 0,65 0,60 0,60 0,550,40
0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:72.8%Quadril:75.1%Micro:72.1%Regula:82.6%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity2/A/Noload
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:B-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
lInear
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Globe 9.0 9.5 10.5
Quadril 8.8 9.4 10.3
Micro 8.9 9.5 10.4
Regula 9.7 10.2 11.1
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,200mmsuspension,nomineralwool αw:0.55,NRC:0.60
Quadril,200mmsuspension,nomineralwool αw:0.50,NRC:0.50
Micro,200mmsuspension,nomineralwool αw:0.65,NRC:0.60
Regula,200mmsuspension,nomineralwool αw:0.10,NRC:0.05
44
X
AB
E
DC
marking and wall angles• Markthelocationof thewallanglesonthewalls
and columns in relation to the required ceilingheight.
• Installthewallanglesatmax.300mmc/c.Choosethe fixings in accordance with the substrate.
corners• Insidecorners(1):cutthecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingto the contrary is specified. Finishwith a cornercover,ifnecessary.
• Outsidecorners(2):mustalwaysbemitred.Finishwithacornercoverifnecessary.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• The location of light fittings and ventilation unitswillhaveaninfluenceonceilinglayout.
• Install thefirstmainrunneratmax.600mmfromthewall.Theothermainrunnersshouldbeinstalledat600/1200mmc/c.
Hangers• Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Direct hangers (2) are secured to the ceiling
using appropriate fixings in accordancewith thesubstrateandlockedtothemainrunnerwithanail.
• Install the first hanger atmax. 400mm from thewall.Theotherhangersshouldbeinstalledatmax.1200mmc/c.
• If loads fromlightfittingsetc.are tobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
INSTAllATIONGUIDE
Fig.1
600 x 600 mm module
Shadowlinetrim1459Mainrunner850Crosstee854Crosstee852Adjustablehanger(typedependsoninstallationdepth)
legend:
A=Max.400mm B=Max.1200mm C=Max.600mmD=Max.1200mm E=Min.63mm
45-44
Installation• Alwayswear clean cottongloveswhen handling
elements. • Install theelementsbypushingthesideofthetile
with the large groove across T-profile, lifting theoppositesideof the tile towards theT-profileandpull the tileback.Toensuregoodalignment, it isimportant that the tiles are installed in the sameorientation.
• Check that all metal clips are resting on theT-profilesandthattheedgesofthetilearebetweentheprofilessothatthetileislockedinposition.
• Friezetilesshouldbeadjustedpreciselyaccordingtothewallangleorshadowlinetrim.Seedetaileddrawingsonnextpage.
• Asanalternative,theceilingcanbefinishedusingPlazaorafixedfrieze-seedetaileddrawingsonnextpage.
cutting and finishing• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.• Ifmetalclipsare installed in theplacewhere the
elementistobecut,theymustberemovedfirst.• Grip theclipwithapairofpliersand twist itoff
gently.• A new metal clip can be pressed into position
with a clip mounting tool available from KnaufDanoline.
fixtures and fittings• With smaller units (of up to3kg)a reinforcement
panelofsufficientstrengthcanbeinstalledbehindthelinearelement.
• The reinforcement panel must extend all theway into the main runners, so that the weight istransferredtothem.
• Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeused
• Unitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
cross profiles• Push the snap-in tongue into the sloton themain
runnerusinglightdownwardpressure.• Ifthereisacrossprofileontheoppositesideofthe
mainrunner,thenewonemustbeontherighthandsideoftheonealreadyinplace.
• If a cross profile is not to be continued into theadjacentmodule the snap-in tonguemustbe splitandbentflat.
adjustment• Checkthatallprofilesarecorrectlyalignedwhen
theentiresuspensiongridhasbeeninstalled.• Adjust the hangers so that they are tant and the
ceilingsurfaceislevel.
main runners• Install themain runners parallel to each other so
thattheslotsaredirectlyoppositeeachother.• Join the main runners longitudinally and lock
them in position by bending the end couplingsbackwards.
• Adjustthelengthsoftheprofileswithplateshears,ahacksaworacross-cutsawwithaspecialblade.
• Makesurethereisahangerbetweentheendjointsofthemainrunnersandthefirebreak.
lInear
46
DETAIlS
linearingridsystem850(S24)directtowall
linearingridsystem850(S24)withPlazafrieze
Crosstee(cuttosize)
Crosstee(cuttosize)
Crosstee
Wallangle
Wallangle
linear
PlazaRegula
Mainrunner
Mainrunner
Filling,e.g.woodenbattenorsealanttape
linear Shadowlinetrim
Hanger
linearingridsystem850(S24)withfixedfriezeon650system
Wallprofile
Wallprofile
Crosstee650system
Crosstee650system
Crosstee
Crosstee
linear
linear
Mainrunner
Mainrunner
Tectopanel(cuttosize)
Plasterboard
Hanger
Hanger
47-46
lInear
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
MainrunnerS24 1366 85030 24x3600x38
CrossteeS24 13741507
8523085430
24x600x3824x1200x38
Crosstee 30813082
5642206956442069
35x600x3835x1200x38
Wallangle 1455 1420 24x3050x24
Shadowlinetrim 1457 1459 12+19x3050x34
Outsidecornerforwallangle
31073108
13341332
for24mmWallanglefor19mmWallangle
Insidecornerforwallangle
31093110
13481346
for24mmWallanglefor19mmWallangle
Wallprofile 3083 511069 30x3050x40.5
Directhanger337633773375
21.521.821.1
5080100
Pinfordirecthanger 11882
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
Clips,Qperf. 3385 MK13 40x401/11
Fixingtoolforclips 3372 - -
48
Recessedgridlookwithstrongshading.Classicandhighlyrobustacousticceiling.Exceptionallyeasytoinstallanddemount.
MARKANT/DEMOUNTABlET-GRIDCEIlING
49-48
Didyouknowthat…
thecardboardingypsumboardsisproducedof100%recycledcellulosekepttogetherbynaturalstarchagents?
marKant
Unity6SystemVistaConturBelgravialinearMarkantPlazaDanotile
AarhusArchitects,Privatehospital,Denmark,Markant,Globe
50
Sizes600x600x12.5mm600x1200x12.5mm*625x625x12.5mm625x1250x12.5mm**NotavailablewithTangentperforation
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest.
PerforationGlobe:10.2%Quadril:13%Micro:10.2%Tangent:19.7%
AlsoavailableasRegula.Otherperforationpatternsaremanufacturedtoorder.
EdgeE(tegular)/S15orS24Recessedgrid
MARKANTDEMOUNTABlET-GRIDCEIlING
Globe,Ø6mm,15mmc/c
Quadril,12x12mm,30mmc/c
Micro,3x3mm,8.3mmc/c
Tangent,4x14mm,10/20mmc/c
51-50
1,0
0,8
0,6
0,4
0,2
0.0
α
Hz400020001000500250125
α 0,65 0,80 0,65 0,55 0,450,45
,
α 0,60 0,70 0,65 0,60 0,450,45
α 0,55 0,65 0,60 0,60 0,550,40
α 0,65 0,80 0,75 0,75 0,750,45
α 0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:72.8%Quadril:75.1%Micro:72.1%Tangent:70.9%Regula:82.6%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity
1/A/Noload 600x600625x625
Globe,Quadril,Micro,Tangent,Regula
2/A/Noload 600x1200625x1250
G1F,Q1F,M1F,R
2/A/30N 600x600625x625
Globe,Quadril,Micro,Regula
2/B/Noload 600x600625x625
Globe,Quadril,Micro,Regula
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:B-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
marKant
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Globe 8.5 9.4 10.0
Quadril 8.4 9.3 9.9
Micro 8.5 9.4 10.0
Tangent 8.4 9.3 9.9
Regula 9.2 10.0 10.6
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,200mmsuspension,nomineralwool αw:0.60,NRC:0.65Quadril,200mmsuspension,nomineralwool αw:0.60,NRC:0.65
Micro,200mmsuspension,nomineralwool αw:0.65,NRC:0.60
Tangent,200mmsuspension,nomineralwool αw:0.80,NRC:0.75
Regula,200mmsuspension,nomineralwool αw:0.10,NRC:0.05
52
X
AB
E
DC
marking and wall angles• Mark the locationof thewallangleson thewalls
and columns in relation to the required ceilingheight.
• Installthewallanglesatmax.300mmc/c.Choosethefixingsinaccordancewiththesubstrate.
corners• Insidecorners(1):cutthecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingto the contrary is specified. Finishwith a cornercover,ifnecessary.
• Outsidecorners(2):mustalwaysbemitred.Finishwithacornercoverifnecessary.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• The location of light fittings and ventilation unitswillhaveaninfluenceonceilinglayout.
• Install thefirstmainrunneratmax.600mmfromthewall.Theothermainrunnersshouldbeinstalledat600/1200mmc/c.
Hangers• Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Direct hangers (2) are secured to the ceiling
using appropriate fixings in accordancewith thesubstrateandlockedtothemainrunnerwithanail.
• Install the first hanger atmax. 400mm from thewall.Theotherhangersshouldbeinstalledatmax.1200mmc/c.
• Ifloadsfromlightfittingsetc.aretobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
INSTAllATIONGUIDE
Fig.1
600 x 600 mm module
Wallangle1420orshadowlinetrim1459Mainrunner850or7500Crosstee854or7514Crosstee852or7512Adjustablehanger(typedependsoninstallationdepth)
legend:
A=Max.400mm B=Max.1200mm C=Max.600mmD=600/1200mm E=Min.120mm
53-52
Installation• Alwayswear clean cottongloveswhen handling
ceilingelements.• Installtheelementsbytiltingthemupbetweenthe
T-profiles.• Checkthatallmetalclipsarerestingonthemain
runnersandthattheedgesofthetilearebetweentheprofilessothatthetileislockedinposition.
cutting• Cuttheelementstosizefromthefrontfacewitha
fine-toothedsaw.• Ifmetalclipsareinstalledwheretheelementisto
becut,theymustberemovedfirst.• Grip theclipwithapairofpliersand twist itoff
gently.• A new metal clip can be pressed into position
with a clip mounting tool available from KnaufDanoline.
fixtures and fittings• Forsizesupto625x625notinTangentperforation,
unitsofupto3kgcanbeinstalleddirectlyintothepanelwithoutreinforcement.
• ForlargermodulesizesandallsizeswithTangentperforation a reinforcement panel of sufficientstrength can be installed behind the Markantelement.
• The reinforcement panel must extend all theway into the main runners, so that the weight istransferredtothem.
• Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeused
• Unitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
cross profiles• Push the snap-in tongue into the sloton themain
runnerusinglightdownwardpressure.• Ifthereisacrossprofileontheoppositesideofthe
mainrunner,thenewonemustbeontherighthandsideoftheonealreadyinplace.
• If a cross profile is not to be continued into theadjacentmodule the snap-in tonguemustbe splitandbentflat.
adjustment• Checkthatallprofilesarecorrectlyalignedwhen
theentiresuspensiongridhasbeeninstalled.• Adjust the hangers so that they are tant and the
ceilingsurfaceislevel.
main runners• Install themain runners parallel to each other so
thattheslotsaredirectlyoppositeeachother.• Join the main runners longitudinally and lock
them in position by bending the end couplingsbackwards.
• Adjustthelengthsoftheprofileswithmetalshears,ahacksaworacircularpowersawwithaspecialblade.
• Makesurethereisahangerbetweentheendjointsofthemainrunnersandthefirebreak.
marKant
54
DETAIlS
Markantingridsystem7500(S15)or850(S24)directtowall
Crosstee(cuttosize)
Crosstee
Shadowlinetrim Markant Mainrunner Markant
WallangleMarkantRegulacutto
sizeandequippedwithadditionalclips
Hanger
Hanger
Hanger
Markantingridsystem7500(S15)or850(S24)withPlazafrieze
Crosstee Crosstee
Plaza Mainrunner MarkantWallangle
Markantingridsystem7500(S15)or850(S24)withfixedfriezeon650system
Wallprofile
Wallprofile
Crosstee650system
Crosstee650systemCrosstee
EdgetrimKS13Markant
Noniushenger
MainrunnerTectopanel(cuttosize)
12.5plasterboardaccordingtosuppliersinstructions
Markantingridsystem7500(S15)or850(S24)withalternativefriezesolutions
Crosstee
MarkantWallangle MainrunnerFriezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
Shadowlinetrim
55-54
marKant
MarkanttilesareavailablewithaspecialSwingfunctionthatfacilitatestheinspectionworkinthecavity.Thedemountedtilesareleftsuspendedverticallyduringtheinspectionwork.
ACCESSORIES
MARKANTSWING
Productname
SAPno.
Productcode
WxlxH(mm)
MainrunnerS24 1366 85030 24x3600x38
CrossteeS24
189513741507
851308523085430
24x300x3824x600x3824x1200x38
MainrunnerS15 1500 750030 15x3000x38
CrossteeS15
15131515
751230751430
15x600x3815x1200x38
Crosstee 30813082
5642206956442069
35x600x3835x1200x38
Wallangle 1455 1438 19x3050x32
Wallangle 1509 1420 24x3050x24
Shadowlinetrim 1457 1459 12+19x3050x34
Outsidecornerforwallangle
31073108
13341332
for24mmWallanglefor19mmWallangle
Insidecornerforwallangle
31093110
13481346
for24mmWallanglefor19mmWallangle
Wallprofile 3083 511069 30x3050x40.5
Directhanger337633773375
21.521.821.1
5080100
Pinfordirecthanger 11882 - -
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
Hold-downclip(forMarkantSwing) 3382 820
Clips 3385 MK13 40x40x1/11
Fixingtoolforclips 3372 - -
56
Functionaldesignwithaclean-cutlook.Straight-forwardacousticceilingwithvisibleT-grid.Robustceiling,easytomount.
PlAZA/DEMOUNTABlET-GRIDCEIlING
57-56
plaza
Unity6SystemVistaConturBelgravialinearMarkantPlazaDanotile
Didyouknowthat...
thankstotheirrobustness,perforatedgypsumboardscanbefullyintegratedwiththewallconstruction,therebycreatingauniformwallsurfacewithacousticperformance?
AlessandroRippellino,RosenbergsArchitects,KVEkenäs,Sweden,Plaza,Globe
58
PerforationGlobe:10.2%Quadril:13%Micro:10.2%Tangent:21.3%AlsoavailableasRegula.Otherperforationpatternsaremanufacturedtoorder.
Sizes600x600x9.5mm* 600x1200x9.5mm*600x600x12.5mm 600x1200x12.5mm*625x625x12.5mm 625x1250x12.5mm**NotavailablewithTangentperforation
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
EdgeA(squareedge)/S15orS24Visiblegrid
Globe,Ø6mm,15mmc/c
Quadril,12x12mm,30mmc/c
Micro,3x3mm,8.3mmc/c
Tangent,4x14mm,10/20mmc/c
PlAZADEMOUNTABlET-GRIDCEIlING
59-58
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,80 0,65 0,55 0,450,45
α 0,60 0,70 0,65 0,60 0,450,45
α 0,55 0,65 0,60 0,60 0,550,40
α 0,65 0,80 0,75 0,75 0,750,45
α 0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:72.8%Quadril:75.1%Micro:72.1%Tangent:70.9%Regula:82.6%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity
1/A/Noload 600x600625x625
Globe,Quadril,Micro,Tangent,Regula
2/A/Noload 600x1200625x1250
G1F,Q1F,M1F,R
2/A/30N 600x600625x625
Globe,Quadril,Micro,Regula
2/B/Noload 600x600625x625
Globe,Quadril,Micro,Regula
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:B-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Globe 7.5 8.1 9.0
Quadril 7.4 8.0 8.9
Micro 7.5 8.1 9.0
Tangent 7.4 8.0 8.9
Regula 8.1 8.7 9.6
plaza
Certificates• FDESlCADeclaration
• DanishIndoorClimatelabelling
• DeclarationofConformity(EN14190)
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,200mmsuspension,nomineralwool αw:0.60,NRC:0.65
Quadril,200mmsuspension,nomineralwool αw:0.60,NRC:0,65
Micro,200mmsuspension,nomineralwool αw:0.65,NRC:0.60
Tangent,200mmsuspension,nomineralwool αw:0.80,NRC:0.75
Regula,200mmsuspension,nomineralwool αw:0.10,NRC:0.05
60
X
AB
E
DC
marking and wall angles• Mark the locationof thewallangleson thewalls
and columns in relation to the required ceilingheight.
• FIxthewallanglesatmax.300mmc/c.Choosethefixingsinaccordancewiththesubstrate.
corners• Insidecorners(1):cutthecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingto the contrary is specified. Finishwith a cornercover,ifnecessary.
• Outside corners (2): must always bemitred andfinishedwithacornercoverifnecessary.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• The location of light fittings and ventilation unitswillhaveaninfluenceonceilinglayout.
• Thefirstmainrunnerisinstalledatmax.600mmfrom thewall. The othermain runners should beinstalledat600/1200mmc/c.
Hangers • Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Direct hangers (2) are secured to the ceiling
usingappropriatefixings inaccordancewith thesubstrate and locked to the main runner with anail.
• Install thefirst hangeratmax.400mm from thewall.Theotherhangersshouldbeinstalledatmax.1200mmc/c.
• If loadsfromlightfittingsetc.aretobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
INSTAllATIONGUIDE
Fig.1
600 x 600 mm module
Wallangle1438orshadowlinetrim1459Mainrunner850or7500Crosstee854or7514Crosstee852or7512Adjustablehanger(typedependsoninstallationdepth)
legend:
A=Max.400mm B=Max.1200mm C=Max.600mmD=600/1200mm E=Min.120mm
61-60
plaza
Installation• Alwayswear clean cotton gloveswhen handling
ceilingelements.• Installtheelements.
cutting• Cuttheelementstosizefromthefrontface.
fixtures and fittings• Forsizesupto625x625notinTangentperforation,
unitsofupto3kgcanbeinstalleddirectlyintothepanelwithoutreinforcement.
• ForlargermodulesizesandallsizeswithTangentperforation a reinforcement panel of sufficientstrengthcanbeinstalledbehindthePlazaelement.
• The reinforcement panel must extend all theway into themain runners, so that theweight istransferredtothem.
• Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeused
• Unitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
cross profiles• Push the snap-in tongue into the sloton themain
runnerusinglightdownwardpressure.• Ifthereisacrossprofileontheoppositesideofthe
mainrunner,thenewonemustbeontherighthandsideoftheonealreadyinplace.
• If a cross profile is not to be continued into theadjacentmodule the snap-in tonguemustbe splitandbentflat.
adjustment• Checkthatallprofilesarecorrectlyalignedwhen
theentiresuspensiongridhasbeeninstalled.• Adjustthehangerssothattheyaretantandthe
ceilingsurfaceislevel.
main runners• Installthemainrunnersparalleltoeachotherso
thattheslotsaredirectlyoppositeeachother.• lockthemainrunnersinpositionbybendingthe
endcouplingsbackwards.• Adjust the lengths of the runners with metal
shears,ahacksaworacircularpowersawwithaspecialblade.
• Make sure there is a hanger between the endjointsofthemainrunnersandthefirebreak.
62
DETAIlS
Plazaingridsystem7500(S15)or850(S24)directtowall
Plazaingridsystem7500(S15)or850(S24)withfixedfrieze
Crosstee(cuttosize) Crosstee
Crosstee/orMainrunner
Crosstee
Wallangle
Wallangle
Plaza
Plaza
Plaza
Mainrunner
Mainrunner
Shadowlinetrim
Shadowlinetrim
Hanger
Friezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
63-62
plaza
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
MainrunnerS24 1366 85030 24x3600x38
CrossteeS24
189513741507
851308523085430
24x300x3824x600x3824x1200x38
MainrunnerS15 1500 750030 15x3000x38
CrossteeS15
15131515
751230751430
15x600x3815x1200x38
Wallangle 1455 1438 19x3050x32
Wallangle 1509 1420 24x3050x24
Shadowlinetrim 1457 1459 12+19x3050x34
Outsidecornerforwallangle
31073108
13341332
for24mmWallanglefor19mmWallangle
Insidecornerforwallangle
31093110
13481346
for24mmWallanglefor19mmWallangle
Directhanger337633773375
21.521.821.1
5080100
Pinfordirecthanger 11882 - -
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
64
Hygieneceilingsuitableforroomswithhighcleaningandinfectioncontrolrequirements.Whitefoil-coveredsurfacewithaclean-cutlook.RobustceilingtoleratingtoughcleaninganddisinfectionagentswithpHlevelsfrom2–13.Clean-roomcertifiedgypsumceiling.
DANOTIlE/DEMOUNTABlET-GRIDCEIlING
65-64
DanotIle
Unity6SystemVistaConturBelgravialinearMarkantPlazaDanotile
Didyouknowthat…
gypsumboardsaresorobustthattheycanbecurvedevenwithsmallradii?
CodaArchitects,BristolHospital,UnitedKingdom,DanotileRegula
66
DANOTIlEDEMOUNTABlET-GRIDCEIlING
Sizes600x600x6.5mm600x1200x6.5mm600x600x9.5mm600x1200x9.5mm625x625x9.5mm
SurfaceFoil-coveredwithpre-impregnated,non-toxicwhitepaperRAl9016(NCSS0300-N,gloss10)
TestedforchemicalresistanceinaccordancewithDIN68861,FIRABS3962andNEMAlD-3-1991.
PerforationAvailableonlyasRegula.
EdgeA(squareedge)/S24orS15Visiblegrid
Certificates
• FDESlCADeclaration
• Cleanroomcertificate(Céralaboreport)
• Physicalresistancetodisinfectants(Céralaboreport)
• ExcellHygieneCertificate
• DanishIndoorClimatelabelling
• DeclarationofConformity(EN14190)
67-66
DanotIle
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
HygieneDanotile can stand rigorous cleaning withconcentrateddisinfectantsanddetergentswithaveryhighpH (up topH13.0)andaverylowpH(downtopH2.5).Danotilehasalsobeentestedforairborneparticles in accordance with ISO 14644-1andareclassifiedasISO5.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
lightreflection86.3%
load-bearingcapacity2/A/Noload 600x1200x6.5
1/B/Noload 600x600x9.5625x625x9.5
2/B/30N 600x600x9.5625x625x9.5
FireclassB-s1,d0
Fireresistance½hourfireresistance(6.5mm)
RobustnessDurable and dirt resistant surface. Productmade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Regula 6.1 6.5 7.6
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Regula,200mmsuspension,nomineralwool αw:0.10,NRC:0.05
HygieneDanotile can stand rigorous cleaning with concentrateddisinfectantsanddetergentswithaveryhighpH(uptopH13.0)andavery lowpH (down topH2.5).Danotilehasalsobeentested for airborne particles in accordance with ISO 14644-1andareclassifiedasISO5.
68
X
AB
E
DC
marking and wall angles• Mark the locationof thewallangleson thewalls
and columns in relation to the required ceilingheight.
• Fixthewallanglesatmax.300mmc/c.Choosethefixingsinaccordancewiththesubstrate.
corners• Insidecorners(1):cutthecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingto the contrary is specified. Finishwith a cornercover,ifnecessary.
• Outside corners (2): must always bemitred andfinishedwithacornercoverifnecessary.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• The location of light fittings and ventilation unitswillhaveaninfluenceonceilinglayout.
• Thefirstmainrunnerisinstalledatmax.600mmfrom thewall. The othermain runners should beinstalledat600/1200mmc/c.
Hangers • Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Direct hangers (2) are secured to the ceiling
usingappropriatefixings inaccordancewith thesubstrate and locked to the main runner with anail.
• Install thefirst hangeratmax.400mm from thewall.Theotherhangersshouldbeinstalledatmax.1200mmc/c.
• If loadsfromlightfittingsetc.aretobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
INSTAllATIONGUIDE
Fig.1
600 x 600 mm module
Wallangle1438orshadowlinetrim1459Mainrunner850or7500Crosstee854or7514Crosstee852or7512Adjustablehanger(typedependsoninstallationdepth)
legend:
A=Max.400mm B=Max.1200mm C=Max.600mmD=600/1200mm E=Min.120mm
69-68
DanotIle
Installation• Alwayswearcleancottongloveswhenhandling
ceilingelements.• Installtheelements.
cutting• Cuttheelementstosizefromthefrontface.
fixtures and fittings• Forsizesupto625x625andmin.thickness9mm,
unitsofupto3kgcanbeinstalleddirectlyintothepanelwithoutreinforcement.
• For larger module sizes and all sizes in 6mmthickness, a reinforcement panel of sufficientstrength can be installed behind the Danotileelement.
• The reinforcement panel must extend all theway into themain runners, so that theweight istransferredtothem.
• Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeused.
• Unitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
cross profiles• Push thesnap-in tongue into thesloton themain
runnerusinglightdownwardpressure.• If there isacrossprofileon theopposite sideof
themainrunner,thenewonemustbeontherighthandsideoftheonealreadyinplace.
• If a cross profile is not to be continued into theadjacentmodule thesnap-in tonguemustbesplitandbentflat.
adjustment• Checkthatallprofilesarecorrectlyalignedwhen
theentiresuspensiongridhasbeeninstalled.• Adjust the hangers so that theyare tant and the
ceilingsurfaceislevel.
main runners• Install themain runnersparallel toeachother so
thattheslotsaredirectlyoppositeeachother.• lockthemainrunnersinpositionbybendingthe
endcouplingsbackwards.• Adjustthelengthsoftherunnerswithmetalshears,
ahacksaworacircularpowersawwithaspecialblade.
• Make sure there is a hanger between the endjointsofthemainrunnersandthefirebreak.
70
DETAIlS
Danotileingridsystem7500(S15)or850(S24)directtowall
Danotileingridsystem7500(S15)or850(S24)withfixedfrieze
Crosstee(cuttosize) Crosstee
Crosstee/orMainrunner
Crosstee
Wallangle
Wallangle
Danotile
Danotile
Danotile
Mainrunner
Mainrunner
Shadowlinetrim
Shadowlinetrim
Hanger
Friezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
71-70
DanotIle
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
MainrunnerS24 1366 85030 24x3600x38
CrossteeS24
13741507
8523085430
24x600x3824x1200x38
MainrunnerS15 1500 750030 15x3000x38
CrossteeS15
15131515
751230751430
15x600x3815x1200x38
Wallangle 1455 1438 19x3050x32
Wallangle 1509 1420 24x3050x24
Shadowlinetrim 1457 1459 12+19x3050x34
Outsidecornerforwallangle
31073108
13341332
for24mmWallanglefor19mmWallangle
Insidecornerforwallangle
31093110
13481346
for24mmWallanglefor19mmWallangle
Directhanger337633773375
21.521.821.1
5080100
Pinfordirecthanger 11882 - -
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
72
UNITY6BRIDGE/DEMOUNTABlESElF-SUPPORTINGCEIlING
Continuouslookwithedgetoedgeperforationsforcorridorsandnarrowrooms.Nosuspensionrunnersandhangersrequired.Openareawithnohangersrevealedwhendemounted.Self-supportingupto2.4m.
73-72
Rendering
Unity6BridgeCorridor400CorridorSwingCorridorF30
unIty 6 brIDge
Didyouknowthat…
theperforationholesingypsumboardsprovideseveralacousticaleffects:soundabsorption,sounddiffusionandsoundreflection?
74
15 612.5
15
Sizes400x1200x9.5mm400x1500x9.5mm400x1800x9.5mm400x2100x9.5mm400x2400x9.5mm400xSpeciallength(900-2400)x9.5mmSurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
UNITY6BRIDGEDEMOUNTABlESElF-SUPPORTINGCEIlING
EdgeD(rebatedandgroovededge)Self-supportingwithvisibletrimattheshortends
PerforationU6:12%
U6,Ø6mm,15mmc/c,12.5mmtoedge
75-74
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,80 0,65 0,55 0,450,45
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICSunIty 6 brIDge
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
lightreflection72.8%
load-bearingcapacity1/A/Noload2/A/30N2/B/Noload
FireclassFull-perforated:A2-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
U6 9.4 9.9 10.7
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Unity6Bridge,200mmsuspension,nomineralwool αw:0.60,NRC:0.65
76
X
A
DE
B C
Fig.1
cutting• Alwayswearcleancottongloveswhenhandling
elements.• Cuttheelementstosizefromthefrontwithafine-
toothed saw. Elements must be shorter than thedistance fromwall towall:3-8mmshorterwhenusingawallangle;43-48mmshorterwhenusingashadowlinetrim.
• Adjustthelengthsoftheprofileswithahacksaworacircularpowersawwithaspecialblade,max.10mmshorterthantheceilingelement.
marking and wall angles• Mark the locationof thewallangleson thewalls
and columns in relation to the required ceilingheight.
• Install Knauf Danoline wall angle type 1430 orshadow line trim type 1469 at max. 300 mmc/c. Choose the fixings in accordance with thesubstrate.
corners• Insidecorners(1):cut thecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingto the contrary is specified. Finish with a cornercover,ifnecessary.
• Outsidecorners(2):mustalwaysbemitred.Finishwithacornercoverifnecessary.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
INSTAllATIONGUIDE
Wallangle1430orshadowline1469Mainrunner65020
Adjustablehanger(typedependsoninstallationdepth)
legend:
A=Max.2400mm B=Max.300mm C=Max.750mmD=Min.300mmE=Min.80mm
77-76
Installation• Alwayswear clean cotton gloveswhen handling
elements.• Pushtheflexrunneroverthegypsumrunnerbefore
installation(1).• Place the elements in position on the wall angle
andpushthemclosetogether(2and3).• Recommendedminimum installation height:when
usingwall angles,300mm,whenusing shadowlinetrims,85mm.
change of direction and niches• Use Knauf Danoline T-profiles type 65020 (35
mmwide) supported by hangerswhen changingdirectionsandinconnectionwithniches.
• Installthefirsthangermax.300mmfromthewall.Otherhangersshouldbeinstalledatmax.750mmc/c.
t-profiles• Join the main runners longitudinally and lock
them in position by bending the end couplingsbackwards.
• Adjustthelengthsoftheprofileswithmetalshears,ahacksaworacircularpowersawwithaspecialblade.
• Makesurethereisahangerbetweentheendjointsofthemainrunnersandthefirebreak.
• TheT-profilemustbefixedtothewallconstruction.
fixtures and fittings• Unitsweighingupto3kgcanbeinstalleddirectly
intothepanelwithoutreinforcement.• N.B.Themaximumcut-out,wheninstallinginthe
centreofthepanelisØ265mm/265x265mm• Unitsover3kg,shouldbesupportedindependently,
sothattheydonotplaceanyloadontheceiling.
Hangers (if t-profiles are used for the ceiling)• Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Install the first hanger atmax.300mm from the
wall.Theotherhangersshouldbeinstalledatmax.750mmc/c.
• If loadsfromlightfittingsetc.aretobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
Joining elements in t-profiles• SecuretheT-profiletothewallconstructionwithan
angle.(1)• At least every 4th element resting on the T-profile
shouldbesecuredagainst slidingusinganangleorbandironatbothends.(2)(3)
unIty 6 brIDge
78
Unity6Bridgedirecttowall
Flexprofile
Flexprofile
Wallangle
Wallangle
Unity6Bridge
Unity6Bridge
Shadowlinetrim
Shadowlinetrim
Unity6Bridgewithfixedfrieze
Unity6Bridge
Unity6Bridge
Flexprofile
Mainrunner/corridor Mainrunner/corridor
Shadowlinetrim Wallangle Friezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
DETAIlS
ConnectorHanger
79-78
ACCESSORIESunIty 6 brIDge
Productname
SAPno.
Productcode
WxlxH(mm)
Flexrunner
35823584358535863574
--------------------
65x1194x4465x1494x4465x1794x4465x2094x4465x2394x44
Mainrunner 1520 65020 35x3600x38
Wallangle 1910 1430 20x3050x40
Shadowlinetrim 1471 1469 20+20x3050x20+20
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
80
CORRIDOR400/DEMOUNTABlESElF-SUPPORTINGCEIlING
Distinctunifiedlookfornarrowroomsandcorridors.Nosuspensionrunnersandhangersrequired.Openareawithnohangersrevealedwhendemountedduringinspectionwork.Self-supportingupto2.4m.
81-80
Didyouknowthat…
synthetic(recycledindustrial)gypsumhasahigherpuritythannaturalgypsum,typically96%vs.80%?
corrIDor 400
Unity6BridgeCorridor400CorridorSwingCorridorF30
Denu&Paradon,Paul-AndréRitzenthalerArchitects,laRodia,France,Corridor400,Micro
82
CORRIDOR400DEMOUNTABlESElF-SUPPORTINGCEIlING
Sizes400x1200x9.5mm400x1500x9.5mm400x1800x9.5mm400x2100x9.5mm400x2400x9.5mm400xSpeciallength(900-2400)x9.5mm
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
EdgeD(rebatedandgroovededge)Self-supportingwithvisibletrimattheshortends
PerforationGlobe:10.6%Quadril:14.2%Micro:10.6%Tangent:21.6%
AlsoavailableasRegula.Otherperforationpatternsaremanufacturedtoorder.
Globe,Ø6mm,15mmc/c Quadril,12x12mm,30mmc/c
Micro,3x3mm,8.3mmc/c Tangent,4x14mm,10/20mmc/c
83-82
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,80 0,65 0,55 0,450,45
α 0,60 0,70 0,65 0,60 0,450,45
α 0,55 0,70 0,65 0,60 0,600,40
α 0,65 0,80 0,75 0,75 0,800,35
α 0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
lightreflectionGlobe:72.8%Quadril:75.1%Micro:72.1%Tangent:70.9%Regula:82.6%
load-bearingcapacityG,Q,M,R:1/A/NoloadG,Q,M,R:2/A/30NG,Q,M,R:2/B/Noload
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:B-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
corrIDor 400
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Globe 9.5 10.0 10.8
Quadril 9.4 9.9 10.7
Micro 9.5 10.0 10.8
Tangent 8.2 8.6 9.4
Regula 10.4 10.9 11.7
EdgeD(rebatedandgroovededge)Self-supportingwithvisibletrimattheshortends
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,200mmsuspension,nomineralwool αw:0.60,NRC:0.65Quadril,200mmsuspension,nomineralwool αw:0.60,NRC:0.65Micro,200mmsuspension,nomineralwool αw:0.65,NRC:0.65Tangent,200mmsuspension,nomineralwool αw:0.80,NRC:0.75Regula,200mmsuspension,nomineralwool αw:0.10,NRC:0.10
84
X
A
DE
B C
cutting• Alwayswear clean cotton gloveswhen handling
elements.• Cuttheelementstosizefromthefrontwithafine-
toothed saw. Elements must be shorter than thedistance fromwall towall:3-8mm shorterwhenusingawallangle;43-48mmshorterwhenusingashadowlinetrim.
• Adjustthelengthsoftheprofileswithahacksaworacircularpowersawwithaspecialblade,max.10mmshorterthantheceilingelement.
marking and wall angles• Mark the locationof thewallangleson thewalls
and columns in relation to the required ceilingheight.
• Install Knauf Danoline wall angle type 1430 orshadow line trim type 1469 at max. 300 mmc/c. Choose the fixings in accordance with thesubstrate.
corners• Insidecorners(1):cut thecornersinafalsemitre
lettingtheendsoverlapeachother,unlessanythingto the contrary is specified. Finish with a cornercover,ifnecessary.
• Outsidecorners(2):mustalwaysbemitred.Finishwithacornercoverifnecessary.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
INSTAllATIONGUIDE
Fig.1
Wallangle1430orshadowline1469Mainrunner65020
Adjustablehanger(typedependsoninstallationdepth)
legend:
A=Max.2400mm B=Max.300mm C=Max.750mmD=Min.300mmE=Min.80mm
85-84
t-profiles• Join the main runners longitudinally and lock
them in position by bending the end couplingsbackwards.
• Adjustthelengthsoftheprofileswithmetalshears,ahacksaworacircularpowersawwithaspecialblade.
• Makesurethereisahangerbetweentheendjointsofthemainrunnersandthefirebreak.
• TheT-profilemustbefixedtothewallconstruction.
Installation• Alwayswear clean cotton gloveswhen handling
elements.• Pushtheflexrunneroverthegypsumrunnerbefore
installation(1).• Place the elements in position on the wall angle
andpushthemclosetogether(2and3).• Recommendedminimum installation height:when
usingwall angles,300mm,whenusing shadowlinetrims,85mm.
fixtures and fittings• Unitsweighingupto3kgcanbeinstalleddirectly
intothepanelwithoutreinforcement.• N.B.Themaximumcut-out,wheninstallinginthe
centreofthepanelisØ265mm/265x265mm.• Unitsover3kg,shouldbesupportedindependently,
sothattheydonotplaceanyloadontheceiling.
Hangers (if t-profiles are used for the ceiling)• Fixadjustablehangers(1)witheyescrewsorsimilar
securelyfastenedtotheprimaryconstruction.• Install the first hanger atmax.300mm from the
wall.Theotherhangersshouldbeinstalledatmax.750mmc/c.
• If loadsfromlightfittingsetc.aretobebornebytheceiling,installadditionalhangers.
• Refertodistancesinfigure1.
Joining elements in t-profiles• SecuretheT-profiletothewallconstructionwithan
angle.(1)• At least every 4th element resting on the T-profile
shouldbesecuredagainst slidingusinganangleorbandironatbothends.(2)(3)
corrIDor 400
change of direction and niches• Use Knauf Danoline T-profiles type 65020 (35
mmwide) supported by hangerswhen changingdirectionsandinconnectionwithniches.
• Installthefirsthangermax.300mmfromthewall.Otherhangersshouldbeinstalledatmax.750mmc/c.
86
DETAIlS
Corridor400directtowall
Flexprofile
Flexprofile
Wallangle
Wallangle
Corridor400
Corridor400
Shadowlinetrim
Shadowlinetrim
Corridor400withfixedfrieze
Corridor400
Corridor400
Connector
Flexprofile
Hanger
Mainrunner/corridor Mainrunner/corridor
Shadowlinetrim
Wallangle
Friezeaccordingtosupplier‘sinstructionsFriezeaccordingto
supplier‘sinstructions
Friezeaccordingtosupplier‘sinstructions
87-86
corrIDor 400
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
Flexrunner
35823584358535863574
--------------------
65x1194x4465x1494x4465x1794x4465x2094x4465x2394x44
Mainrunner 1520 65020 35x3600x38
Wallangle 1910 1430 20x3050x40
Shadowlinetrim 1471 1469 20+20x3050x20+20
AdjustablehangerThesizespecifi-cationindicatesthemin.andmax.range
148414881489149014921494149614971498
1102211030-9911030110401107011090111201115011200
120-200200-270250-320250-440380-690500-940750-1210750-14401000-1940
88
Highlyfunctionalacousticceilingsolutionforcorridors.Swingfunction–leavingtilessuspendedverticallyduringinspectionandmaintenancework.Exceptionallyeasyaccesstoinstallationsrequiringnotools.Distinctlinearlookwithalight,floatingeffectthankstotheairgapsaroundthetile.
CORRIDORSWING/DEMOUNTABlESElF-SUPPORTINGCEIlING
89-88
Didyouknowthat…
gypsumhasstoodthetestoftimefromthepyramidstoamodernversatilebuildingmaterialoftoday?
corrIDor sWIng
Unity6BridgeCorridor400CorridorSwingCorridorF30
PyramidenArchitects,SahlgrenskaHospital,Sweden,CorridorSwing,Micro
90
CORRIDORSWINGDEMOUNTABlESElF-SUPPORTINGCEIlING
Sizes600x1200x12.5mm600x1500x12.5mm600x1800x12.5mm
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
EdgeE(tegular)Novisiblegrid;airgapsaroundtiles
PerforationGlobe:10%Quadril:11.5%Micro:9.9%
AlsoavailableasRegula.Otherperforationpatternsaremanufacturedtoorder.
Globe,Ø6mm,15mmc/c Quadril,12x12mm,30mmc/c Micro,3x3mm,8.3mmc/c
91-90
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,75 0,65 0,55 0,450,45
α 0,60 0,65 0,60 0,55 0,400,45
α 0,55 0,65 0,60 0,60 0,550,40
α 0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:72.8%Quadril:75.1%Micro:72.1%Regula:82.6%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity2/A/Noload
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:B-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
corrIDor sWIng
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Globe 9.2 9.4 10.7
Quadril 9.1 9.3 10.6
Micro 9.1 9.3 10.6
Regula 9.9 10.1 11.4
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,200mmsuspension,nomineralwool αw:0.60,NRC:0.65Quadril,200mmsuspension,nomineralwool αw:0.65,NRC:0.70
Micro,200mmsuspension,nomineralwool αw:0.70,NRC:0.70
Regula,200mmsuspension,nomineralwool αw:0.05,NRC:0.05
92
X
F
A B
D EC
G
Dimensional outline, wall junction• Mindicatesthemoduleline.• Theremustbea12mmgaponeachsideofM.• Thebracket721175(a)isfixedtothewallatc/c
800mm.• TheW-swing2profile (b) is fixed to thebracket
withtheW34bolt(c).
Dimensional outline, fixed frieze• Mindicatesthemoduleline.• Theremustbea12mmgaponeachsideofM.• The bracket 721175 (a) is fixed to the vertical
profiles and horizontal U-profiles are installed sothefixedfriezecanbescrewedontothem.
• TheW-swing2 (b) profile is fixed to the bracketwiththeW34bolt(c).
Dimensional outline, demountable frieze• Mindicatesthemoduleline.• Theremustbea12mmgaptowardstheCorridor
Swingelementanda18mmgaptothefrieze.• Horizontal U-profiles and vertical C-profiles are
installed in order to create a rigid frame for theswingprofile.
• W-swing 2 (b) and 4A profiles are fixed at c/c800mmintheverticalsteelprofileswiththeW34bolt(c).
• Thewallangleisfixedtothewallatc/c400mm.
planning the ceiling surface• The board elements are 24mm smaller than the
modulesize: Module: 600x1200/1500/1800 Element: 576x1176/1476/1776 Opening: 624x1224/1524/1824
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
INSTAllATIONGUIDE
Fig.1
ProfilW-swing2ProfilW-swing3BracketW-swing2Fixedprofile
A=Max.100mm B=Max.800mm C=Max.1800mmD=Max.100mmE=Max.800mmF=Max.66mmG=Min.145mm
legend:
93-92
Installation of swing hanger• TheSwinghanger isfixed to the fastenedSW15
profileandtheotherSW15SwingprofileispushedintoitsslotsothehangerisfixedintheholeoftheSW15profile.
• Now the other SW15 profile can be fixed usingpreviousdescribedmethod.
• It is not recommended installing the hanger bytensioningasitwillgiveaninappropriatesidewaysforceontheSW15profiles.
Installation of swing cross profile • Thecrossprofile isplacedonto themetal clip so
that thehole in thecrossprofile isdirectlyabovethecentreholeinthemetalclip.
• The cross profile is pressed tightly against theelement.
• The screw is fixed through thehole in theprofileandthecentreholeinthemetalclip.
Installation of the elements• Startoutbyhangingtheelementsalongoneofthe
sides.• Theelementiskeptverticalwiththehangerpointing
up and the hanger is clasped on theW-swing2profile.
fixing of the metal clip• Thebracketsarefixedtothewallorverticalsteel
profilesatc/cmax.800mm.TheremustalwaysbeabracketbehindthejointsofSwing2profiles.
• The lowestedgeof thebracketshouldbe65mmhigherthanthedesiredceilingheight.
• Itisveryimportantthattheframeworkisrigidsoitcannotdeformtheelementswheninstalled.
assembly of the elements• Theelementscomewithpre-fittedclips.• The U-profile-swing are fixed with the supplied
screwsthroughthepre-fittedclipsintotheelement.• Thedistancebetweentheendoftheprofiletothe
edgeoftheelementmustbe15mm.• OnlyoneSW15swingprofileisfixedatthisstage.• Thebaseforfixingtheloadbearingprofilesmust
beplaneandsolid.• Theremust be nodeflection of the profile during
thefixingofit.
profile distances• The W-swing 2 profiles are installed under the
bracketwiththeW34nutandbolt.• Nowthedistancebetweenthe“suspensionpoints”
ontheW-swing2profilesmustbeadjusted,sothedistancebetweenthemisthelengthoftheelementminus50mm.
• The two Swing profiles must be installed, so thecut-outsaredirectlyoppositeeachotherduetothefollowinginstallationoftheactualelement.
corrIDor sWIng
94
DETAIlS
CorridorSwingdirecttowall-crosssectionincorridor
CorridorSwingwithfixedfrieze-crosssectionincorridor
BracketW-swing2
BracketW-swing2
BracketW-swing2
BracketW-swing2
CorridorSwing
CorridorSwing
CorridorSwing
CorridorSwingFixedfriezewithTectopanel
FixedfriezewithMitexpanel
FixedfriezewithMitexpanel
ProfileW-swing2
ProfileW-swing2
ProfileW-swing2
ProfileW-swing2
ScrewW34
ScrewW34
ScrewW34
ScrewW34
CorridorSwingwithfixedfrieze-lengthsectionincorridor
CorridorSwingwithfixedfrieze-lengthsectionincorridor
95-94
corrIDor sWIng
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
ProfileW-swing2 3322 730162 42x2400x16
ProfileW-swing3 6602 729198 92x2400x16
ProfileW-swing4A 7610 731618 85x2400x66
ProfileW-swing5 6605 729200 68x2400x53
BracketW-Swing2 3336 721175 70x58x80
Nut/BoltNutW34 13261 718473 -
Swinghanger 3334 ---- Ø4x582x35
Screwforprofiles 10530 K/K11 11
U-profile-swing333133323333
---
45x1146x2045x1446x2045x1746x20
Crossprofile 10282 - 45x479x20
96
Acousticceilingsolutionforfireescaperoutes.Highfireresistance–meetingtoughrequirementsinDIN4102.Fireresistantfrombothsides.Testedwithinstallationsbuiltin.Distinctunifiedlookwithfinelinesbetweentheplanks.
CORRIDORF30/DEMOUNTABlESElF-SUPPORTINGCEIlING
97-96
Didyouknowthat…
perforatedgypsumboardsusesoundresonanceorcounter-soundtoenhancesoundabsorption?
corrIDor f30
Unity6BridgeCorridor400CorridorSwingCorridorF30
EurowingsAirport,Germany,CorridorF30,Globe
98
Sizes300xlengthx100mmMax.length:2800mm
SurfaceFoil-coveredwithpre-impregnatedwhitepaperNCSS0300-N(RAl9016,gloss10)
TestedforchemicalresistanceinaccordancewithDIN68861,FIRABS3962andNEMAlD-3-1991
PerforationGlobe:10.0Quadril:12.8Micro:10.0
AlsoavailableasRegula.
EdgeD(rebatedandgroovededge)Self-supportingwithvisibletrimattheshortends
CORRIDORF30DEMOUNTABlESElF-SUPPORTINGCEIlING
Globe,Ø6mm,15mmc/c Quadril,12x12mm,30mmc/c Micro,3x3mm,8.3mmc/c
99-98
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,30 0,65 0,80 0,60 0,400,10
α 0,30 0,55 0,75 0,60 0,400,15
α 0,40 0,60 0,70 0,65 0,550,15
α 0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:74.1%Quadril:76.2%Micro:73.5%Regula:86.3%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity1/B/170N
FireclassDIN4102-2FireresistanceclassF30
RobustnessDurable and dirt resistant surface. Productmade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
corrIDor f30
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Globe 29.7 30.7 37.8
Quadril 29.7 30.7 37.8
Micro 29.7 30.7 37.8
Regula 30.5 31.5 38.6
Max.load:Themaximumloadonadjacentwalls/friezesis54.0kg/lm.ThisincludestheweightoftheF30elements,wallanglesandfireboardstripsbutisexcludingtechnicalinstallationsintheceiling.
• DIN4102-2FireClassificationCertificates
• DeclarationofConformity(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,62mmsuspension,nomineralwool αw:0.55,NRC:0.60Quadril,62mmsuspension,nomineralwool αw:0.55,NRC:0.55Micro,62mmsuspension,nomineralwool αw:0.60,NRC:0.60Regula,62mmsuspension,nomineralwool αw:0.05,NRC:0.05
100
X
A
D
B C
Wall angles• Mark the locationof thewallangleson thewalls
and columns in relation to the required ceilingheight.
• Installthewallanglesatmax.400mmc/consolidwalls,312.5mmonplasterboardwallsand208mminconnectionwithfixedfriezes.
• Choose the fixings in accordance with the walltype/substrate.
• Bothinsideandoutsidecornersmustbemitred.• Recessed 12.5 x 105mm gypsum strips can be
installedbehindthewallanglesifashadoweffectis required. See detailed drawing on next pagespread.
lining• line thewall angleswith15mmfireboard strips
120mminheight.• Install an additional fireboard strip 60 mm in
height in connectionwithadjustedendelements.Seedetaileddrawingonnextpagespread.
• Securethestripswithscrews.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
INSTAllATIONGUIDE
Fig.1
Wallangle78402wallangles7840placedbacktoback2Noniusstraps
legend:
A=Max.2400mm B=Max.300mm C=Max.650mmD=Min.225mm
101-100
cutting• Adjustthelengthoftheelementsusingahacksaw
orajigsawwithabladeformetal.• Adjustthewidthoftheelementswithahandsaw.• Elementsmustbeadjustedsothatatleast20mm
lays on thewall angles.Clearance in relation tothefireboardstripattachedmustnotexceed3mm.
Installation – last element• Adjust and install the last element andpush it in
overthewallangle.
Installation• Alwayswear clean cotton gloveswhen handling
F30elements.• Place the elements on the wall angle and push
themtogether.• Ceilingpanelsareself-supportinginroomsofupto
2800mminwidthandrequirenofurthersupport.
closing the ceiling• Closetheceilingwiththelastwholeelement.
corrIDor f30
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
change of direction / niches / large rooms• Use two wall angles screwed back to back and
supported by hangers (install 15 x 105 mmfireboard strips between the profiles if a shadoweffectisrequired).
• Installthefirsthangermax.300mmfromthewall.Otherhangersshouldbeinstalledatmax.650mmc/c.
• UseNoniushangersorbracketscombinedwith10mmdiameterthreadedrod.
102
DETAIlS
CorridorF30withfixedfrieze
UDProfileCDProfile
Noniushanger
Noniushanger
Fireboardstrips
Fireboardstrips
40mmstonewool
Wallangle2x12.5mmPlasterboard(GKF)CorridorF30
CorridorF30lengthextension
Plasterboard(GKF)
Plasterboard(GKF)
Fireboardstrips
Fireboardstrips
Wallangle
Wallangle
Wallangle
CorridorF30
CorridorF30
CorridorF30directtowall
Plasterboard(GKF)
103-102
corrIDor f30
ACCESSORIES
Productname
SAPno.
Productcode
WxlxH(mm)
Wallangle 7840 - 40x2500x60
104
Ceiling&wallliningwithaunifiedexpressionwithoutvisiblejoints.Suitableforflatsurfacesandforcurvingonsiteorfromthefactory.
DESIGNPANEl/NON-DEMOUNTABlECEIlING
105-104
DesIgnpanel
DesignpanelTectopanelContrapanelDanopanelSolopanelStratopanel
Didyouknowthat…
gypsumwasusedbytheancientEgyptiansasjointingmaterialinmonumentsbuiltover4000yearsago?
DesignPodiumCo.,ltd,lanpusKindergarten,SouthKorea,Designpanel,Micro
106
SizesDimension Availablewith:
900x2700x12.5mm Globe,Quadril,Micro
1200x2400x12.5mm Globe,Quadril,Micro
900x2400x12.5mm Tangent
SurfaceUntreated
DESIGNPANElNON-DEMOUNTABlECEIlING
EdgeA1/A1(EN520)4taperededgesNovisiblejoints
PerforationGlobe:5.3-9.8%Quadril:7.8-13%Micro:7.1-9.8%Tangent:13.3-15.8%
AlsoavailableasRegula.Otherperforationpatternsareavailabletoorder.
Quadril,12x12mm,30mmc/c
Tangent,4x14mm,10/20mmc/c
Globe,Ø6mm,15mmc/c
Micro,3x3mm,8.3mmc/c
107-106
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,70 0,80 0,75 0,60 0,500,35
α 0,65 0,75 0,70 0,65 0,500,40
α 0,60 0,65 0,65 0,60 0,550,40
α 0,60 0,70 0,70 0,65 0,650,35
α 0,15 0,05 0,05 0,05 0,050,30
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
lightreflectionDependsonthepaintusedonsite.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity2/A/Noload 900x2700 G1F,
Q1F,Q2F,M1F,M2F
2/B/30N 1200x2400 G2F,Q2F,Q4F,M2F
1/A/Noload 900x2400 T3l1,T3l2,T3l4
FireclassA2-s1,d0
FireratingClass1;K110,A2-s1,d0
CanbeusedinaBD30construction.
RobustnessMadeofrobust,glassfibrereinforcedmaterialwith excellent pressure resistance and canthereforebeusedonwallsaswellasceilings.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
DesIgnpanel
ACOUSTICS
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Globe 8.9 9.0
Quadril 8.8 8.9
Micro 8.9 8.9
Tangent 8.8 8.9
Regula - -
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
G1F,65mmsuspension,50mmmineralwool αw:0.65,NRC:0.70Q1F,65mmsuspension,50mmmineralwool αw:0.65,NRC:0.70M1F,65mmsuspension,50mmmineralwool αw:0.65,NRC:0.65T3l1,65mmsuspension,50mmmineralwool αw:0.70,NRC:0.65Regula,65mmsuspension,50mmmineralwool αw:0.10,NRC:0.10
108
300
A
furring• Furrings can be of wood or steel profiles; CD2
system can also be used as susbtrate - for moredetailspleaseseeinstallationguideforContrapanelasceilinglining.
• Also see the sections “Fire” and “Acoustics” onnextpage.
Installation• Installthefirstrowofpanelswiththehelpofstring.• Seedistancesinfigure1.• Thepanels are supplied undersizedandmust be
installed at distances of up to 4 mm from eachothertoensurethatitispossibletoinsertfillerallthewayupbetweentheedgesofthepanels.
• The perforated fields must be lined up in bothdirections.
• Cuttheelementstosizefromthefrontwithafine-toothedsaw.
ceiling layout and furring system• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• Please note that expansion joints must beestablished on extensive ceiling surfaces atmax.intervals of 15 metres in both directions. Seedetaileddrawingsonknaufdanoline.com
• As a rule, the furring must be at right angles tothelongitudinaldirectionoftheelementsatcentresof300mmtoensurethatthepanelsareproperlysupported.
• Also see the sections “Fire” and “Acoustics” onnextpage.
screw distances 900 x 2700• Fixthepanelsacoordingtothetemplateabove.• For Designpanel 900 Micro M1F the screws in
theperforated field canbeomitted if there is norequirement for cladding class (K1-10) and theroom is not exposed to relative humidity above70%.
BestPractice:Handlingthepanelswithcarewillavoiddamageandsurfacecontaminationpriortopaintingandtherebyensureagoodendresult.
Thefurringshouldbemin.60mmwideattheshortendjoints(ifwoodisused;thesteelfurringcanbemin.45mm).Theremainingfurringcanbe45mmwide.
legend:
A Max.300mm
• Screw(SN3.5x30)
INSTAllATIONGUIDE
Fig.1
109-108
filling• Applythefirstlayeroffiller(EasyFillerlight).Make
sureitispressedallthewayupbetweenthepaneledgesandavoidgettingfillerintheperforations.
• Applyfillertapetothewetfiller.• Thefirstfillingandapplicationoffillertapecanbe
carriedout ina single, very simpleoperationbyusingaMiniBazooka.
• Allow the filler to dry. Make sure that the filleris completely dry before sanding. Sand withfine sandpaper. Be careful not to damage thecardboardsurface.
• Applythesecondlayeroffiller(EasyFillerlight).• Allow the filler to dry. Make sure that the filler
is completely dry before sanding. Sand withfine sandpaper. Be careful not to damage thecardboardsurface.
• Apply the third layer of filler (Easy Filler light).Make sure that thefiller is completelydrybeforesanding.Sandwithfinesandpaperuntilthejointiscompletely smooth.Becarefulnot todamage thecardboardsurface.
screw distances 1200 x 2400• Fixthepanelsacoordingtothetemplateabove.
screw distances 900x2400 (tangent)• Fixthepanelsacoordingtothetemplateabove.
filling screw holes• Checkthatthescrewshavebeencountersunk.• Apply filler (Knauf Finish Pastös or Easy Filler).
Overfillslightly.• We recommend the use of Knauf Danogips
„Acousticfillingknife forholes“ inorder toavoidfillergettingintotheperforationholes.
acoustics• A perforated gypsum panel will lose its acoustic
functioniftheperforationsareblocked(thisappliestothefrontandbackofthepanel).
• Where applicable, a vapour barrier shouldthereforealwaysbeplacedbehindthefurringssothatitdoesnotcomeintocontactwiththebackoftheperforatedpanel.
• When installing Designpanel on a fixed surfacewerecommendfillingthecavitybetweenthebackof the panel and the furring with mineral wool.This is primarily to ensure low frequency soundabsorption.
fire• If there is a requirement for BD30 follow the
instructionsforthisconstruction.• Thefurringshouldbedimensionedinaccordance
with the load in question and should be at least45mm in width.Where BD30 constructions areconcerned25x100mmfurringsshouldbeused.
DesIgnpanel
painting• Make sure that the filler is completelydryand the
surfaceissmoothandfreefromdust.• Primingshouldbecarriedoutinaccordancewiththe
paintmanufacturer’sinstructions.• Applythepaintwitharollersothattheacousticfelt
on theperforatedpanels is not sealed.Usea finemohairroller.
• Makesurethatthepaintisnottoothickandavoidapplyingtoomuchpaintatatime.
• Spraying cannot be recommended as this couldinfluencetheacousticpropertiesofthepanels.
110
DETAIlS
Designpanelwith1layerfurring
Designpanelwithcross-furring
Mineralwool
Furring
Furring
Furring
Furring
Designpanel
Designpanel
Designpanel
Designpanel
Mineralwool
Mineralwool
Vapourbarrier
Vapourbarrier
Vapourbarrier
Vapourbarrier
Filling,taperededges
Mineralwool
Mineralwool
111-110
DesIgnpanel
Pressthepanelagainstthetemplateusingabatten,movingitevery100mm.Securethepanelontheothersideofthetemplate.Dryingtime:1½-2hours.
laythepaneloveratemplate.Securethepanelononesideofthetemplate.
Applywateronthefrontfaceandleavefor30minutes.Ifnecessarythepanelcanbecoveredinplastictoassistthepanelinabsorbingthewater.
CURVEDPANElS
ACCESSORIES
CD2syste
maccessorie
sfors
teelsub
strate
Productname SAPno.
Productcode
WxlxH(mm)
Primary/secondaryCD60/27-profile 2648 4378352 60x4000x27
WallangleUD28/27 2649 5927696 28x3000x27
lengthconnectorCD60/27
4281 5927695 59x80x28
Cross-fitting 4284 5927703 -
Splitpinforhanger 8513 5214556 -
Noniushangerlower 8510 5214555 -
Noniushangerupper85mm 8511 5214557 105-185
Noniushangerupper135mm 8512 5214558 135-235
Noniushangerupper235mm 9201 5214559 235-340
Noniushangerupper340mm 9202 5214560 340-440
Noniushangerupper440mm 9203 5214561 440-540
Noniushangerupper540mm 9204 5214562 540-640
Noniushangerupper640mm 9205 5214563 640-740
Noniushangerupper740mm 9206 5214564 740-840
Noniushangerupper840mm 9207 5214565 840-940
Noniushangerupper940mm 9208 5214566 940-1040
ScrewSN3.5x30 9275 8644932 3.5x30
EasyFiller - 235309 -
Fillingtape - 2043 -
MiniBazooka 14870 - -
Fillingknife 73962 - -
112
60120
480
60 120480
60 120180
60120
180
60 120330
60120
330
60 120780
60780
60
FollowingperforationpatternsareavailableforDesignpanelGlobe,QuadrilogMicro900x2700mm.
FollowingperforationpatternsareavailableforDesignpanelGlobe,QuadrilogMicro1200x2400mm.
PATTERNSDESIGNPANEl900x2700
PATTERNSDESIGNPANEl1200x2400
Perforationpercentage
G1F 9.8%
Q1F 13%
M1F 9.8%
Perforationpercentage
G2F 7.4%
Q2F 10.2%
M2F 7.1%
Perforationpercentage
G2F 8.6%
Q2F 11.6%
M2F 8.4%
Perforationpercentage
G4F 5.3%
Q4F 7.8%
G1F,Q1F,M1F
G2F*,Q2F,M2F
G2F,Q2F&M2FG2F,Q2F&M2F
G4F*&Q4F
*Nonstandard
113-112
2260
2400
60180
120
900
70
1060
2400
60180
120
900
70 140
460
2400
460
60180
120
900
70 140140
DesIgnpanel
FollowingperforationpatternsareavailableforDesignpanelTangent900x2400mm.
PATTERNSDESIGNPANEl900x2400
Perforationpercentage
T3l1 15.8%
Perforationpercentage
T3l2 15.0%
Perforationpercentage
T3l4 13.3%
T3l1
T3l2
T3l4
114
Acousticceilingandwallliningofferingflexibility.Blankcanvasprovidingnumerousopportunitiesforcreativedesign.Availableinalargenumberofsizes.Suitableforcurvingonsiteorfromfactory.
TECTOPANEl/NON-DEMOUNTABlECEIlING
115-114
tectopanel
DesignpanelTectopanelContrapanelDanopanelSolopanelStratopanel
Didyouknowthat…
perforatedgypsumboards,incaseoffire,actasanaturalsprinklerinthebuilding?
FjordenArchitects,AalborgUniversity,Denmark,Tectopanel,Quadril
116
TECTOPANElNON-DEMOUNTABlECEIlING
Sizes300x1200x12.5mm G,Q,M,R
400x600x9.5mm R
400x600x12.5mm G,R
400x1200x12.5mm T
600x600x12.5mm G,Q,M,T,R
600x1200x12.5mm G,Q,R
600x2400x12.5mm G,Q,R
625x625x12.5mm G,Q,M,R
625x1250x12.5mm G,Q,ROthersizesonrequest
SurfaceUntreated
PerforationGlobe:9-11%Quadril:10.6-14%Micro:9.5-10.7%Tangent:21.1-21.3%
AlsoavailableasRegula.Otherperforationpatternsaremanufacturedtoorder.
EdgeB(bevellededge)Visiblejoints
Globe,Ø6mm,15mmc/c
Quadril,12x12mm,30mmc/c
Micro,3x3mm,8.3mmc/c
Tangent,4x14mm,10/20mmc/c
117-116
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,70 0,80 0,75 0,60 0,500,35
α 0,65 0,75 0,70 0,65 0,500,40
α 0,65 0,70 0,65 0,60 0,600,40
α 0,70 0,95 0,95 0,85 0,850,35
α 0,15 0,05 0,05 0,05 0,050,30
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
lightreflectionDependsonthepaintusedonthesite.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity1/A/Noload2/B/Noload
FireclassA2-s1,d0
FireratingClass1;K110,A2-s1,d0CanbeusedinaBD30construction
RobustnessMadeofrobust,glassfibrereinforcedmaterialwith excellent pressure resistance and canthereforebeusedonwallsaswellasceilings.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
tectopanel
ACOUSTICS
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Globe 9.2 10.1
Quadril 9.1 10.0
Micro 9.1 10.19
Tangent 8.8 9.6
Regula 9.9 10.9
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,65mmsuspension,50mmmineralwool αw:0.65,NRC:0.70
Quadril,65mmsuspension,50mmmineralwool αw:0.65,NRC:0.70Micro,65mmsuspension,50mmmineralwool αw:0.65,NRC:0.60
Tangent,65mmsuspension,50mmmineralwool αw:0.90,NRC:0.85Regula,65mmsuspension,50mmmineralwool αw:0.10,NRC:0.10
118
A
C
B
furring• Furrings can be of wood or steel depending on
currentfireregulations.• Furringsshouldbeatleast50mminwidth.• Also see the sections “Fire” and “Acoustics” on
nextpage.
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
element layout• Install the panels beginning in the centre of the
room.• Installthefirstrowwiththehelpofstring.
Fig.1
BestPractice:Handlingthepanelswithcarewillavoiddamageandsurfacecontaminationpriortopaintingandtherebyensureagoodendresult.
Thefurringshouldbemin.60mmwideattheshortendjoints(ifwoodisused;thesteelfurringcanbemin.45mm).Theremainingfurringcanbe45mmwide.
legend:
A=Max.300mm A=Max.200mm C=Max.300mm
• Screw(SN3.5x30)
Paneledge
INSTAllATIONGUIDE
119-118
painting• Makesurethatthefilleriscompletelydryandthe
surfaceisfreefromdust.• Primingshouldbecarriedoutinaccordancewith
thepaintmanufacturer’sinstructions.• Useafineshort-hairedmohair roller toapply the
paint.• Makesurethatthepaintisnottoothickandavoid
applying toomuchpaintata timeso that itdoesnotcreatea„film“overtheperforationholes.
filling screw holes• Checkthatthescrewshavebeencountersunk.• Apply filler (Knauf Finish Pastös or Easy Filler).
Overfillslightly.• We recommend the use of Knauf Danogips
„Acousticfillingknife forholes“ inorder toavoidfillergettingintotheperforationholes.
sanding• Makesurethatthefilleriscompletelydry.• Sand with fine sandpaper until the surface is
completelysmooth.Becarefulnottodamagethecardboardsurface.
fire• If there is a requirement for BD30, follow the
instructionsforthisconstruction.
acoustics• A perforated gypsum panel will lose its acoustic
functioniftheperforationsareblocked(thisappliestothefrontandbackofthepanel).
• Where applicable, a vapour barrier shouldthereforealwaysbeplacedbetweentherafterandfurringssothatitdoesnotcomeintocontactwiththebackoftheperforatedpanel.
• WheninstallingTectopanelbeneathafixedceilingitmaybenecessarytoinsertmineralwool(KnaufDanolinecanoffermineralwoolpackedinplastic)intothecavitybetweenthebackofthepanelandthe fixed ceiling. This is primarily to ensure lowfrequencysoundabsorption.
tectopanel
120
DETAIlS
Furring
Furring
Furring
Furring
Tectopanel
Tectopanel
Tectopanel
Tectopanel
Vapourbarrier
Vapourbarrier
Vapourbarrier
Vapourbarrier
MineralwoolTectopanelwith1layerfurring
Mineralwool
Mineralwool
Mineralwool
Mineralwool
Tectopanelwithcross-furring
121-120
tectopanel
CURVEDPANElS
ACCESSORIES
Pressthepanelagainstthetemplateusingabatten,movingitevery100mm.Securethepanelontheothersideofthetemplate.Dryingtime:1½-2hours.
laythepaneloveratemplate.Securethepanelononesideofthetemplate.
Applywateronthefrontfaceandleavefor30minutes.Ifnecessarythepanelcanbecoveredinplastictoassistthepanelinabsorbingthewater.
Productname SAPno. Productcode WxlxH
(mm)
ScrewSN3.5x30 9275 8644932 3.5x30mm
FinishPastös 9631 1468992 20kg
Fillingknife 73962 - -
122
Acousticalperformanceandimpactresistanceinonesolution.Acousticceilingorwallliningwithadistinctunifiedlook.TestedinaccordancewithDIN18032(EN13964)-thetoughestrequirementsforimpactresistance.Foil-coveredsurface–easytoclean.
CONTRAPANEl/NON-DEMOUNTABlECEIlING
123-122
contrapanel
DesignpanelTectopanelContrapanelDanopanelSolopanelStratopanel
Didyouknowthat…
thankstotheirrobustness,perforatedgypsumboardscanbefullyintegratedwiththewallconstruction,therebycreatingauniformwallsurfacewithacousticperformance?
levalloisPerretSportscenter,France,Contrapanel,Globe
124
Sizes600x1200x12.5mm600x1800x12.5mm600x2400x12.5mm
SurfaceFoil-coveredwithpre-impregnatedwhitepaperGloss10TestedforchemicalresistanceinaccordancewithDIN68861,FIRABS3962andNEMAlD-3-1991
PerforationGlobe,G1F:10.2%
AlsoavailableasRegula
EdgeB(bevellededge)Visiblejoints
CONTRAPANElNON-DEMOUNTABlECEIlING
Globe,Ø6mm,15mmc/c
125-124
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,80 0,65 0,55 0,450,45
α 0,20 0,10 0,05 0,05 0,050,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:74.1%Regula:86.3%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity1/B/Noload2/B/30N
FireclassB-s1,d0
FireratingClass1;K110,B-s1,d0CanbeusedinaBD30construction
RobustnessDurable and dirt resistant surface. Productmadeofrobust,glassfibrereinforcedmaterialwith excellent pressure resistance and canthereforebeusedonwallsaswellasceilings.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
contrapanel
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Globe 8.9 9.7
Regula 9.7 10.5
Certificates• DIN4102-2FireClassification
• DanishIndoorClimatelabelling
• DeclarationofConformity(EN14190)
• MPAcertificate-impactresistance
ImpactresistanceContrapanelisespeciallydesignedtomeetthetoughrequirementsforwallandceilingliningsinfacilitiesusedintensivelyforsport,sucharesporthallsandgymnasiums.
ThepanelsshownovisibledeformationafterthetestscarriedoutinaccordancewithEN13964orDIN18032.
Contrapanelmeetsthetoughestclass3requirementsinaccordancewithEN13964forimpactresistantceilinglinings,andtheeventougherrequirementsinDIN18032forimpactresistantwalllinings,makingtheproductidealevenforhandballorhockeycourts.
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,200mmsuspension,nomineralwool αw:0.65,NRC:0.70
Regula,200mmsuspension,nomineralwool αw:0.10,NRC:0.10
126
Fig. 1
A B
C D
F
H
GE
•
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
primary profiles• Connectthetwopartsofthehangerswithtwosplit
pins,oneimmediatelyabovetheother.• Place the primary profiles at a max. distance of
900mmfromeachother.
Installing the wall profile• Markout.• Install UD profile 28/27 with a max. distance
betweenscrewsof400mm.Choosethefixingsinaccordancewiththesubstrate.
Hangers• Securetheupperparttotheconstructionaboveit
at900mmc/c.• Securethelowerparttotheprimaryprofile.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
WallangleUD28/27CDprofile60/27
Crossfitting
Noniushanger(typedependntoninstallationdepth)
WhiteScrewWS25S
Paneledge
legend:
INSTAllATIONGUIDE
Fig.1
A=Max.300mm B=300mmC=Max.900mm
D=Max.900mm E=Max.200mm F=Max.900mmmm
G=Min.80mm H=Min.80mm
127-126
Installation• Always wear cotton gloves when handling the
panels.• Mark the position of screws on theContrapanel.
Usethesuppliedtemplateforthisifnecessary.• Installtheelementsfromthecentre.Installthefirst
rowwiththehelpofstring.• Secure screwsmin.15mm from the edgeof the
elementat300mmc/c.• Usewhitescrews.
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.
Joining cD profiles• JointheCDprofiles(bothprimaryandsecondary
profiles)withthehelpoflengthconnectors.• Thejointscanbemadeasbuttjoints.
secondary profiles• Placeacrossfittingontheprimaryprofile.• Presstheunderlyingsecondaryprofileintoit.• Placesecondaryprofilesat300mmc/c.• Adjustthelocationsofthesecondaryprofilesand
lockthecrossfitting.
contrapanel
128
DETAIlS
ContrapanelonCD2system
SecondaryCDprofile
PrimaryCDprofile Crossfitting
WallprofileUD
WallprofileUD
PrimaryCDprofile
SecondaryCDprofile Whitescrew
Noniushanger
Noniushanger
Contrapanel
Contrapanel
129-128
contrapanel
ACCESSORIES
Productname SAPno.
Productcode
WxlxH(mm)
Primary/secondaryCD60/27-profile 2648 4378352 60x4000x27
WallangleUD28/27 2649 5927696 28x3000x27
lengthconnectorCD60/27
4281 5927695 59x80x28
Cross-fitting 4284 5927703 -
Splitpinforhanger 8513 5214556 -
Noniushangerlower 8510 5214555 -
Noniushangerupper85mm 8511 5214557 105-185
Noniushangerupper135mm 8512 5214558 135-235
Noniushangerupper235mm 9201 5214559 235-340
Noniushangerupper340mm 9202 5214560 340-440
Noniushangerupper440mm 9203 5214561 440-540
Noniushangerupper540mm 9204 5214562 540-640
Noniushangerupper640mm 9205 5214563 640-740
Noniushangerupper740mm 9206 5214564 740-840
Noniushangerupper840mm 9207 5214565 840-940
Noniushangerupper940mm 9208 5214566 940-1040
WhitepaintedscrewWS32T-for1layeronwood 6389 5688308 32
WhitepaintedscrewWS42T-for2layersonwood 14621 1432504 42
WhitepaintedscrewWS25S-for1layeronsteel 219774 1448934 25
WhitepaintedscrewWS38S-for2layersonsteel 219780 1448939 38
130
Acousticceilingandwallliningwithadistinctunifiedlook.Pre-paintedsurfaceandconcealedfixingsofferingaquickandeasyceilingorwallsolutionthatrequiresnofillingorpainting.
DANOPANEl/NON-DEMOUNTABlECEIlING
131-130
Danopanel
DesignpanelTectopanelContrapanelDanopanelSolopanelStratopanel
Didyouknowthat…
ourproductrangeincludesaspecialpurposeceilingandwallpanelthatmeetsthetoughestimpactresistancerequirementsandcanbeusedinsportshalls,gymnasiumsandotherfacilitiesusedintensivelyforsport?
TegnestuenVirumgården,TorstorpSeniorCenter,Denmark,Danopanel,Globe
132
Sizes600x600x12.5mm
SurfaceStandardwhitepaintedsurface(closestmatchRAl9003,gloss5)Othercoloursavailableonrequest
EdgeB(bevellededge)Visiblejoints
DANOPANElNON-DEMOUNTABlECEIlING
PerforationGlobe:10.2%Quadril:13%Micro:10.2%*Tangent:21.3%
AlsoavailableasRegula.Otherperforationpatternsareavailabletoorder.
*N.B.ThedirectionofTangentperforationisdeterminedbythefurringorientation.
Globe,Ø6mm,15mmc/c
Quadril,12x12mm,30mmc/c
Micro,3x3mm,8.3mmc/c
Tangent,4x14mm,10/20mmc/c
133-132
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,70 0,80 0,75 0,60 0,500,35
α 0,65 0,75 0,70 0,65 0,500,40
α 0,65 0,70 0,65 0,60 0,600,40
α
α
0,70 0,95 0,95 0,85 0,850,35
0,15 0,05 0,05 0,05 0,050,30
Danopanel
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:72.8%Quadril:75.1%Micro:72.1%Tangent:70.9%Regula:82.6%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
loadbearingcapacity1/A/Noload2/B/Noload
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:B-s1,d0
FireratingClass1;K110,A2-s1,d0CanbeusedinaBD30construction
RobustnessMadeofrobust,glassfibrereinforcedmaterialwith excellent pressure resistance and canthereforebeusedonwallsaswellasceilings.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Globe 9.2 10.1
Quadril 9.1 10.0
Micro 9.2 10.1
Tangent 9.1 10.0
Regula 9.9 10.9
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,65mmsuspension,50mmmineralwool αw:0.65,NRC:0.70Quadril,65mmsuspension,50mmmineralwool αw:0.65,NRC:0.70Micro,65mmsuspension,50mmmineralwool αw:0.65,NRC:0.60Tangent,65mmsuspension,50mmmineralwool αw:0.90,NRC:0.85Regula,65mmsuspension,50mmmineralwool αw:0.10,NRC:0.10
134
•
B
A
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• The wooden battens must be at least 70 mm inwidthwithc/cof300mm.
• Theactualceilingconstructionshouldbedeterminedbythelocalbuildingregulations.
element layout• Alwayswearcottongloveswhenhandlingpanels.• Install theelementsbeginning in thecentreof the
room.• Installthefirstrowwiththehelpofstring.
fixing• Secure the elements by tightening the screws
throughtheholesinthemetalclips.• It is important thatscrewsareverticalsothat their
headstakeupaslittlespaceaspossible.
Installation of following elements• Install thenextelementsbyslidingthemetalclips
behind theprecedingpanel(s) and tightening thescrewsthroughtheholesinthefreemetalclips.
INSTAllATIONGUIDE
Furringmin.70mmwide
Clips(pre-fixedonthebackofDanopanel
ScrewSN3.5x30
Paneledge
legend:
A=Max.300mm B=300mm
Fig.1
135-134
finishing elements• Securethelastrowdirectlythoughthepanelsusing
whitescrews.• Install additional battens to compensate for the
thicknessofthemetalclips.• Installation can be completedwith an underlying
shadow line trim. White screws can be usedto secure the final panel or screw heads cansubsequentlybefilled,sandedandpainted.
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.• Ifmetalclipshavebeeninstalledintheplacewhere
theelementistobecut,theymustberemovedfirst.• Griptheclipswithapairofpliersandtwistitoff
gently.• A new metal clip can be pressed into position
with a clip mounting tool available from KnaufDanoline.
acoustics• A perforated gypsum panel will lose its acoustic
functioniftheperforationsareblocked(thisappliestothefrontandbackofthepanel).
• Where applicable, a vapour barrier shouldthereforealwaysbeplacedbetweentherafterandbattens so that itdoesnotcome intocontactwiththebackoftheperforatedpanel.
• When installingaceilingbeneathafixedsurfaceitmaybenecessarytoinsertmineralwool(KnaufDanolinecanoffermineralwoolpackedinplastic)intothecavitybetweenthebackofthepanelandthe fixed ceiling. This is primarily to ensure lowfrequencysoundabsorption.
• A perforated gypsum panel is dependent on anacoustic cavity behind it in order to achieve itsacousticproperties.
Danopanel
136
DETAIlS
Mineralwool
Mineralwool
Mineralwool
Mineralwool
Whitescrew
Whitescrew
Danopanel
Danopanel
Vapourbarrier
Vapourbarrier
Furring
Furring
Plywoodstrip
Plywoodstrip
Danopanelon1layerfurring
Whitescrew
Whitescrew
Danopanel
Danopanel
Mineralwool
Mineralwool
Vapourbarrier
Vapourbarrier
Furring
Furring
Plywoodstrip
Plywoodstrip
Danopaneloncross-furring
137-136
Danopanel
ACCESSORIES
Productname SAPno.
Productcode
WxlxH(mm)
WhitepaintedscrewWS32T 6389 5688308 32
WhitepaintedscrewWS42T 14621 1432504 42
ClipsBE13 3389 8187486 40x55x1/10
Fixingtoolforclips 3372 7997083 -
138
Continuousperforationstotheedgeofferingafluid,monolithiclook.Achoiceofseamlessordiscreetjoints.Acousticgypsumliningforceilingandwallsurfaces.
SOlOPANEl/NON-DEMOUNTABlECEIlING
139-138
solopanel
DesignpanelTectopanelContrapanelDanopanelSolopanelStratopanel
Didyouknowthat…
KnaufDanolineproductrangeincludesahygieneceilingthatiscleanroomcertifiedandcanbeusedinlaboratoriesandotherpremiseswithhighinfectioncontrolrequirements?
HenrikJais-Nielsen&MatsWhiteArchitectsAB,HusN,Sweden,Solopanel,G10/23
140
G8/18
G15/30 G12/20/66
G10/23
Q8/18
G12/25
G8/12/50
SOlOPANElNON-DEMOUNTABlECEIlING
Perforationtype Perforationpercentage Sizes*(mm)
SK
FF
MF
G8/18 15.5% 900x2700/1188x1998 1188x1998 1188x1998
G10/23 14.8% 897x2760/1196x2001 1196x2001 1196x2001
G12/25 18.1% 900x2700/1200x2000 1200x2000 1200x2000
G15/30 19.6% 900x2700/1200x1980 - -
Q8/18 19.8% 900x2700/1188x1998 1188x1998 -
G8/12/50 13.1% 900x2700/1200x2000 - -
G12/20/66 19.6% 924x2706/1188x1980 1188x1980 1188x1980
*Exactpanelsizesvaryfrommodulesizesaccordingtoedgetype.
Perforation EdgeSK,FF&MFSK/FF:NovisiblejointsMF:Discreetjoint
SurfaceUntreated
MF
FF
SK
141-140
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,75 0,65 0,60 0,700,45
α 0,60 0,65 0,60 0,50 0,550,45
α 0,65 0,80 0,65 0,50 0,600,45
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,60 0,70 0,60 0,55 0,650,45
α 0,60 0,65 0,60 0,55 0,600,45
α 0,65 0,75 0,65 0,60 0,600,45
α 0,65 0,75 0,65 0,60 0,600,45
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
lightreflectionDependsonthepaintusedonsite.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity2/A/Noload2/B/30N
FireclassA2-s1,d0
RobustnessMadeofrobust,glassfibrereinforcedmaterialwith excellent pressure resistance and canthereforebeusedonwallsaswellasceilings.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
solopanel
Perforation Tileweight(kg/m2)
G8/18 8.8
G10/23 8.8
G12/25 8.5
G15/30 8.4
Q8/18 8.3
G8/12/50 9.0
G12/20/66 8.4
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
G8/18,200mmsuspension,nomineralwool αw:0.60,NRC:0.60G10/23,200mmsuspension,nomineralwool αw:0.60,NRC:0.60G12/25,200mmsuspension,nomineralwool αw:0.65,NRC:0.65G15/30,200mmsuspension,nomineralwool αw:0.65,NRC:0.65
Q8/18,200mmsuspension,nomineralwool αw:0.65,NRC:0.65G8/12/50,200mmsuspension,nomineralwool αw:0.60,NRC:0.60G12/20/66,200mmsuspension,nomineralwool αw:0.60,NRC:0.65
142
A B
C D
EG
H
F
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• Please note that expansion joints must beestablishedonextensive ceiling surfacesatmax.intervals of 15 metres in both directions. Seedetaileddrawingsonknaufdhanoline.com.
• Where conditions indicate an increased riskof movement in a building, this must be takeninto account by reducing the distance betweenexpansionjoints.
primary profiles• Connectthetwopartsofthehangerswithtwosplit
pins,oneimmediatelyabovetheother.
Installing the wall profile• Markout.• Install the wall profile UD 28/27. Choose the
methodoffixinginaccordancewiththesubstrate.
Hangers• Securetheupperparttotheconstructionaboveit
at900mmc/c.Choosethefixingsinaccordancewiththesubstrate.
• Securethelowerparttotheprimaryprofile.
BestPractice:Handlingthepanelswithcarewillavoiddamageandsurfacecontaminationpriortopaintingandtherebyensureagoodendresult.
INSTAllATIONGUIDE
Fig.1
WallprofileUD28/27
CDprofile60/27
Crossfitting
Noniushanger(typedependingoninstallationdebth)
Paneledge
A=Max.300mm B=300mmC=Max.900mm D=Max.900mm
E=Max.900mm F=Max.900mmG=Min.80mm H=Min.80mm
•ScrewSN3,5x30
143-142
preparing panels• Breakall edgeswith fine sandpaperon the front
sothatthecardboardcannotriseduringpainting.• Brushtheedgesfreefromgypsumdustandprime
themwithKnaufTiefengrund(universalprimer).
Installation• Useastringoralasertoensurethattheperforation
rowsareflush.Note: Thepanelsmustall face inthesamedirection(redmarkagainstbluemark).
• Makesurethatthescrewsarecountersunkwithoutdamagingthecardboardsurface.
positioning• SKpanels are supplied undersized, andmust be
installedatdistancesof2-5mmfromeachothertoensurethatitispossibletoinsertfillerallthewayupbetweentheedges.
• Useamountinghooktoensurethecorrectdistancebetweenperforationrowsatthejoints.
• Seedistancesinpreviousillustration.
Joining cD-profiles• Join the CD profiles with the help of length
connectors.
secondary profiles• Placeacrossfittingontheprimaryprofile.• Presstheunderlyingsecondaryprofileintoit.• Adjustthelocationsofthesecondaryprofilesand
lockthecrossfitting.• Sedistancesinfigure1.
Installation sequence• Alwayswearcottongloveswhenhandlingpanels.• Begininstallationinthecentreoftheroom.
solopanel
SK/FF/MF
SK/FF/MF
SK
SK
144
SK/FF/MF SK/FF
SK/FF
cutting• Cut the elements to size from the front with a
fine-toothedsaw.• PrimetheedgeswithKnaufTiefengrund(universal
primer).
filling• Checkthatthescrewsareundersunkandthatthe
panelsarenotpushedclosetogether.• Check that theedgeshavebeenprimedandare
freefromdust.• UseKnaufUniflottforfilling.
preparing Knauf uniflott filter• Prepare the filler according to the instructions on
thefillingpackage.• Fillthetubewithjointfillerwiththehelpofaputty
knife.• Attachthejointingnozzle.• Insertthetubeandnozzleintoajointinggun.
SK/FF
filling• Fillthejointwithfiller(KnaufUniflot).Useajointing
gun or press the filler into the jointwith a fillingknife.Overfillslightlyandmakesurethatthefillerispressedallthewayupbetweentheedgesofthepanelsandavoidgettingfillerintheperforations.
• Press thefillerupagainby runningafingeroverthejoint.Fillagain.
• Allowthefillertodryforabout45minutes.• Removesurplusfiller.• Allowthefillertodry.• Apply the second layer of filler (Knauf Finish
Pastös).Overfillslightly.• Allowthefillertodry.
INSTAllATIONGUIDE
145-144
filling screw holes• Applythefiller(KnaufFinishPastös).Overfillslightly.
We recommend the use of Knauf Danogips„Acousticfillingknifeforholes“inordertoavoidfillergettingintotheperforationholes.
• Allowthefillertodry.
sanding• Makesurethatthefilleriscompletelydry.• Sand with fine sandpaper until the surface is
completelysmooth.Becarefulnot todamage thecardboardsurface.
painting• Makesurethatthefilleriscompletelydryandthe
surfaceissmoothandfreefromdust.• Primingshouldbecarriedoutinaccordancewith
thepaintmanufacturer’sinstructions.• Applythepaintwitharollersothattheacousticfelt
ontheperforatedpanelsisnotsealed.Useafinemohairroller.
• Makesurethatthepaintisnottoothickandavoidapplyingtoomuchpaintatatime.
SK/FF/MF
SK/FF/MF
SK/FF/MF
solopanel
146
DETAIlS
SolopanelonCD2system
Noniushanger
Crossfitting Primaryprofile
Primaryprofile
Primaryprofile
WallprofileUD Solopanel Secondaryprofile Secondaryprofile JointFilling
Secondaryprofile
lengthconnector
Noniushanger
CrossfittingPrimaryprofile
Expansionjoint
Plasterboardstrip Plasterboardstrip
Solopanel
Secondaryprofile
Solopanel-expansionjoint
Noniushanger
Noniushanger
147-146
solopanel
ACCESSORIES
Produktname SAPno.
Productcode
WxlxH(mm)
Primary/secondaryCD60/27-profile 2648 4378352 60x4000x27
WallangleUD28/27 2649 5927696 28x3000x27
lengthconnectorCD60/27
4281 5927695 59x80x28
Cross-fitting 4284 5927703 -
Splitpinforhanger 8513 5214556 -
Noniushangerlower 8510 5214555 -
Noniushanger,upper85mm 8511 5214557 105-185
Noniushanger,upper135mm 8512 5214558 135-235
Noniushanger,upper235mm 9201 5214559 235-340
Noniushanger,upper340mm 9202 5214560 340-440
Noniushanger,upper440mm 9203 5214561 440-540
Noniushanger,upper540mm 9204 5214562 540-640
Noniushanger,upper640mm 9205 5214563 640-740
Noniushanger,upper740mm 9206 5214564 740-840
Noniushanger,upper840mm 9207 5214565 840-940
Noniushanger,upper940mm 9208 5214566 940-1040
KnaufTiefengrund(UniversalPrimer) 9209 5214577 5l
KnaufPastös 9631 1468992 20kg
KnaufUniflott
2509
2507
7802739
8644932
25kg
5kg
Fillertubeset 9220 5214576 -
Fillingknife 73962 - -
ScrewsSN3.5x30 9275 8644932 3.5x30
Mountinghook
8/1810/2312/2515/308/12/5012/20/66
921292139214921592169217
-
2pcs2pcs2pcs2pcs2pcs2pcs
148
Continuousrandomperforationpatternofferingafluid,monolithiclook.Acousticgypsumliningforceilingandwallsurfaces.
STRATOPANEl/NON-DEMOUNTABlECEIlING
149-148
stratopanel
DesignpanelTectopanelContrapanelDanopanelSolopanelStratopanel
Didyouknowthat…
gypsumboardsusedforKnaufDanolineproductsaremadeof90%industryrecycledgypsum,9%recycledgypsumand1%recycledpaper?
Kjær&Richter,lMO,Denmark,Stratopanel,G8/15/20
150
Perforation SurfaceUntreated
EdgeSK&FFNovisiblejoints
*Exactpanelsizesvaryfrommodulesizesaccordingtoedgetype.
Perforationtype Perforation% Sizes*(mm)
SK
FF
G8/15/20 9.9% 1200x1875/1200x2500 1200x1875/1200x2500
G12/20/35 9.8% 1200x1875/1200x2500 1200x1875/1200x2500
STRATOPANElNON-DEMOUNTABlECEIlING
G8/15/20
G12/20/35
SK
FF
151-150
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,50 0,55 0,50 0,40 0,450,40
α 0,50 0,60 0,45 0,35 0,350,40
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
lightreflectionDependsonthepaintusedonsite.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity2/A/Noload2/B/30N
FireclassA2-s1,d0
RobustnessMadeofrobust,glassfibrereinforcedmaterialwith excellent pressure resistance and canthereforebeusedonwallsaswellasceilings.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
stratopanel
Perforation Tileweight(kg/m2)
G8/15/20 9.3
G12/20/35 9.3
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
G8/15/20,200mmsuspension,nomineralwool αw:0.50,NRC:0.50G12/20/35,200mmsuspension,nomineralwool αw:0.45,NRC:0.50
152
A B
C D
EG
H
F
ceiling layout• Divide the ceiling surface from the centre of the
room or in accordance with the existing ceilingplans.
• Please note that expansion joints must beestablishedonextensive ceiling surfacesatmax.intervals of 15 metres in both directions. Seedetaileddrawingsonknaufdanoline.com.
• Where conditions indicate an increased riskof movement in a building, this must be takeninto account by reducing the distance betweenexpansionjoints.
primary profiles• Connectthetwopartsofthehangerswithtwosplit
pins,oneimmediatelyabovetheother.
Installing the wall profile• Markout.• Install the wall profile UD 28/27. Choose the
methodoffixinginaccordancewiththesubstrate.
Hangers• Securetheupperparttotheconstructionaboveit
at900mmc/c.Choosethefixingsinaccordancewiththesubstrate.
• Securethelowerparttotheprimaryprofile.
BestPractice:Handlingthepanelswithcarewillavoiddamageandsurfacecontaminationpriortopaintingandtherebyensureagoodendresult.
INSTAllATIONGUIDE
Fig.1
WallprofileUD28/27
CDprofile60/27
Crossfitting
Noniushanger(typedependingoninstallationdebth)
Paneledge
legend:
A=Max.300mm B=300mmC=Max.900mm D=Max.900mm
E=Max.900mm F=Max.900mmG=Min.80mm H=Min.80mm
•ScrewSN3,5x30
153-152
SK/FFSK
SK/FF
preparing panels• Breakall edgeswith fine sandpaperon the front
sothatthecardboardcannotriseduringpainting.• Brushtheedgesfreefromgypsumdustandprime
themwithKnaufTiefengrund(universalprimer).
Installation• Useastringoralasertoensurethattheperforation
rowsareflush.Note: Thepanelsmustall face inthesamedirection(redmarkagainstbluemark).
• SKpanels are supplied undersized, andmust beinstalledatdistancesof2-5mmfromeachothertoensurethatitispossibletoinsertfillerallthewayupbetweentheedges.
• Makesurethatthescrewsarecountersunkwithoutdamagingthecardboardsurface.
Joining cD-profiles• Join the CD profiles with the help of length
connectors.
secondary profiles• Placeacrossfittingontheprimaryprofile.• Presstheunderlyingsecondaryprofileintoit.• Adjustthelocationsofthesecondaryprofilesand
lockthecrossfitting.• Sesdistancesinfigure1.
Installation sequence• Begininstallationinthecentreoftheroom.
stratopanel
154
SK/FF SK/FF
SK/FF
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.• PrimetheedgeswithKnaufTiefengrund(universal
primer).
filling• Checkthatthescrewsarecountersunkandthatthe
panelsarenotpushedclosetogether.• Check that theedgeshavebeenprimedandare
freefromdust.• UseKnaufUniflottforfilling.
preparing Knauf uniflott filler• Prepare the filler according to the instructions on
thefillingpackage.• Fillthetubewithjointfillerwiththehelpofaputty
knife.• Attachthejointingnozzle.• Insertthetubeandnozzleintoajointinggun.
SK/FF
filling• Fillthejointwithfiller(KnaufUniflot).Useajointing
gunorpress the filler into the jointwitha fillingknife.Overfillslightlyandmakesurethatthefillerispressedallthewayupbetweentheedgesofthepanelsandavoidgettingfillerintheperforations.
• Press thefillerupagainbyrunningafingeroverthejoint.Fillagain.
• Allowthefillertodryforabout45minutes.• Removesurplusfiller.• Allowthefillertodry.• Apply the second layer of filler (Knauf Finish
Pastös).Overfillslightly.• Allowthefillertodry.
INSTAllATIONGUIDE
155-154
SK/FF
filling screw holes• Apply the filler (Knauf Finish Pastös). Overfill
slightly. We recommend the use of KnaufDanogips „Acoustic filling knife for holes“ inorder toavoidfillergetting into theperforationholes.
• Allowthefillertodry.
sanding• Makesurethatthefilleriscompletelydry.• Sand with fine sandpaper until the surface is
completelysmooth.Becarefulnottodamagethecardboardsurface.
painting• Makesurethatthefilleriscompletelydryandthe
surfaceissmoothandfreefromdust.• Primingshouldbecarriedoutinaccordancewith
thepaintmanufacturer’sinstructions.• Applythepaintwitharollersothattheacousticfelt
ontheperforatedpanelsisnotsealed.Useafinemohairroller.
• Makesurethatthepaintisnottoothickandavoidapplyingtoomuchpaintatatime.
stratopanel
156
DETAIlS
StratopanelonCD2system
Stratopanel-expansionjoint
Noniushanger
CrossfittingPrimaryprofile
Primaryprofile
Primaryprofile
WallprofileUD Solopanel Secondaryprofile Secondaryprofile JointFilling
Secondaryprofile
lengthconnector
Noniushanger
CrossfittingPrimaryprofile
Expansionjoint
Plasterboardstrip Plasterboardstrip
Solopanel
Secondaryprofile
Noniushanger
Noniushanger
157-156
stratopanel
ACCESSORIES
Produktname SAPno.
Productcode
WxlxH(mm)
Primary/secondaryCD60/27-profile 2648 4378352 60x4000x27
WallangleUD28/27 2649 5927696 28x3000x27
lengthconnectorCD60/27
4281 5927695 59x80x28
Cross-fitting 4284 5927703 -
Splitpinforhanger 8513 5214556 -
Noniushangerlower 8510 5214555 -
Noniushanger,upper85mm 8511 5214557 105-185
Noniushanger,upper135mm 8512 5214558 135-235
Noniushanger,upper235mm 9201 5214559 235-340
Noniushanger,upper340mm 9202 5214560 340-440
Noniushanger,upper440mm 9203 5214561 440-540
Noniushanger,upper540mm 9204 5214562 540-640
Noniushanger,upper640mm 9205 5214563 640-740
Noniushanger,upper740mm 9206 5214564 740-840
Noniushanger,upper840mm 9207 5214565 840-940
Noniushanger,upper940mm 9208 5214566 940-1040
KnaufTiefengrund(UniversalPrimer) 9209 5214577 5l
KnaufPastös 9631 1468992 20kg
KnaufUniflott
2509
2507
7802739
8644932
25kg
5kg
Fillertubeset 9220 5214576 -
Fillingknife 73962 - -
ScrewsSN3.5x30 9275 8644932 3.5x30
158
Ceiling&wallliningwithaunifiedexpressionwithoutvisiblejoints.Suitableforflatsurfacesandforcurvingonsiteorfromthefactory.
DESIGNPANEl/WAlllININGS
159-158
DesIgnpanel
DesignpanelTectopanelContrapanelSolopanelStratopanelKinopanelAmfipanelAdit
Didyouknowthat…
0.13%ofseawatercontentisgypsumandthattherearelargequantitiesofdesiccatednaturalgypsumaroundtheMediterranean?
liljewallArchitects,Biotech,Sweden,DesignpanelWalllinings,Micro
160
EdgeA1/A1(EN520)4taperededgesNovisiblejoints
DESIGNPANElWAlllININGS
SizesDimension Availablewith:
900x2700x12.5mm Globe,Quadril,Micro
1200x2400x12.5mm Globe,Quadril,Micro
900x2400x12.5mm Tangent
SurfaceUntreated
PerforationGlobe:5.3-9.8%Quadril:7.8-13%Micro:7.1-9.8%Tangent:13.3-15.8%
AlsoavailableasRegula.Otherperforationpatternsareavailabletoorder.
Globe,Ø6mm,15mmc/c
Micro,3x3mm,8.3mmc/c
Quadril,12x12mm,30mmc/c
Tangent,4x14mm,10/20mmc/c
161-160
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,70 0,80 0,75 0,60 0,500,35
α 0,65 0,75 0,70 0,65 0,500,40
α 0,60 0,65 0,65 0,60 0,550,40
α 0,60 0,70 0,70 0,65 0,650,35
α 0,15 0,05 0,05 0,05 0,050,30
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
lightreflectionDependsonthepaintusedonsite.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
FireclassA2-s1,d0
FireratingClass1;K110,A2-s1,d0;BD30
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
DesIgnpanel
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Globe 8.9 9.0
Quadril 8.8 8.9
Micro 8.9 8.9
Tangent 8.8 8.9
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
G1F,65mminstallationdepth,50mmmineralwool αw:0.65,NRC:0.70Q1F,65mminstallationdepth,50mmmineralwool αw:0.65,NRC:0.70M1F,65mminstallationdepth,50mmmineralwool αw:0.65,NRC:0.65T3l1,65mminstallationdepth,50mmmineralwool αw:0.70,NRC:0.65Regula,65mminstallationdepth,50mmmineralwool αw:0.10,NRC:0.10
162
•
A
B
C
BestPractice:Handlingthepanelswithcarewillavoiddamageandsurfacecontaminationpriortopaintingandtherebyensureagoodendresult.
furring• DependingoncurrentfireregulationsDesignpanel
canbeinstalledonwoodorsteelfurrings.• Furrings can be vertical or horizontal but should
ingeneralbeatrightanglestothedirectionofthepanelstoensurethattheendedgesofthepanelsareproperlysupported.
• Furringsshouldbeatleast45mminwidth.• Alsoseethesection“Acoustics”onnextpage.
layout• Perforated wall panels are normally installed on
the upper section of a wall in accordance withacoustic requirementsand the shapeof the roominquestion.
• However, perforated panels can also be used tocoveranentirewall,dependingonthedegreeofphysicalimpact.
• Follow any available drawings or divide thesurfaceofthewallsothattheperforatedmodulesarepositionedsymmetricallyintheroom.
• Expansionjointsshouldbeestablishedonextensivewall surfacesat intervalsofmax.15metres.Seedetaileddrawingsonknaufdanoline.com.
Installation• Installthefirstrowofpanelswiththehelpofstring.• Seedistancesinfigure1.• Thepanelsare suppliedundersizedandmustbe
installed at distances of up to 4 mm from eachothertoensurethatitispossibletoinsertfillerallthewayupbetweentheedgesofthepanels.
• The perforated fields must be flush in their ownrowsandatrightanglestotheadjacentfields.
• Cuttheelementstosizefromthefrontwithafine-toothedsaw.
INSTAllATIONGUIDE
Fig.1
45mmZ-profile
45mmU-profileScrewSN3.5x30
PaneledgeA=Max.300mm B=Max.200mmC=300mm
legend:
163-162
DesIgnpanel
filling• Applythefirstlayeroffiller(EasyFillerlight).Make
sureitispressedallthewayupbetweenthepaneledgesandavoidgettingfillerintheperforations.
• Applyfillertapetothewetfiller.• Thefirstfillingandapplicationoffillertapecanbe
carried out in a single, very simple operation byusingaMiniBazooka.
• Allow the filler todry.Make sure that the filler iscompletely dry before sanding. Sand with finesandpaper.Becarefulnottodamagethecardboardsurface.
• Allowthefillertodry.• Applythesecondlayeroffiller(EasyFillerlight).• Allow the filler todry.Make sure that the filler is
completely dry before sanding. Sand with finesandpaper.Becarefulnottodamagethecardboardsurface.
• Apply the third layer of filler (Easy Filler light).Make sure that the filler is completely dry beforesanding. Sandwith fine sandpaper until the jointiscompletelysmooth.Becarefulnottodamagethecardboardsurface.
filling screw holes• Checkthatthescrewshavebeencountersunk.• Applythefirstlayeroffiller(EasyFillerlight).• Allowthefillertodry.• Sandwithfinesandpaper.• Apply the second layer of filler (Knauf Finish
Pastös),overfillslightly.• Allowthefillertodry.• Sand with fine sandpaper until the surface is
completelysmooth.Becarefulnottodamagethecardboardsurface.
painting• Makesurethatthefilleriscompletelydryandthe
surfaceisfreefromdust.• Primingshouldbecarriedout inaccordancewith
thepaintmanufacturer’sinstructions.• Applythepaintwitharollersothattheacousticfelt
ontheperforatedpanelsisnotsealed.Useafinemohairroller.
• Makesurethatthepaintisnottoothickandavoidapplyingtoomuchpaintatatime.
• Spraying cannot be recommended as this couldinfluencetheacousticpropertiesofthepanels.
acoustics• A perforated gypsum panel will lose its acoustic
functioniftheperforationsareblocked(thisappliestothefrontandbackofthepanel).
• Where applicable, a vapour barrier shouldthereforealwaysbeplacedbehindthefurringssothatitdoesnotcomeintocontactwiththebackoftheperforatedpanel.
• When installing Designpanel on a fixed surfacewerecommendfillingthecavitybetweenthebackof the panel and the furring with mineral wool.This is primarily to ensure low frequency soundabsorption.
164
DETAIlS
Designpanel-integratedacousticwall
Zprofile
Perforatedconnector
Furring
Mineralwool
Jointfilling-taperededges
Jointfilling-taperededges
Mineralwool
Designpanel
Designpanel
Mitex-mitreddesignelement
Designpanel-add-onacousticwalllining
165-164
ACCESSORIES
DesIgnpanel
Pressthepanelagainstthetemplateusingabatten,movingitevery100mm.Securethepanelontheothersideofthetemplate.Dryingtime:1½-2hours.
laythepaneloveratemplate.Securethepanelononesideofthetemplate.
Applywateronthefrontfaceandleavefor30minutes.Ifnecessarythepanelcanbecoveredinplastictoassistthepanelinabsorbingthewater.
CURVEDPANElS
Productname SAPno. Productcode WxlxH
(mm)
Z-profile 214604 - 25x45x45x3000
ScewsSN3,5 9275 8644932 3.5x30
EasyFiller -14140
235309
10l
15l
Fillertape - 2043 75m
Fillingknife 73962 - -
166
Acousticceilingandwallliningofferingflexibility.Blankcanvasprovidingnumerousopportunitiesforcreativedesign.Availableinalargenumberofsizes.Suitableforcurvingonsiteorfromfactory.
TECTOPANEl/WAlllININGS
167-166
tectopanel
DesignpanelTectopanelContrapanelSolopanelStratopanelKinopanelAmfipanelAdit
Didyouknowthat…
KnaufDanolineacousticalceilingsandwallscanmeetyournationalrequirementsintermsofacoustics?
Arkkitehtitoimistolarkas&laineOy,OfficebuildingOutokumpu,Finland,Tectopanel,Quadril
168
EdgeB(bevellededge)Visiblejoints
TECTOPANElWAlllININGS
Sizes300x1200x12.5mm G,Q,M,R
400x600x9.5mm R
400x600x12.5mm G,R
400x1200x12.5mm T
600x600x12.5mm G,Q,M,T,R
600x1200x12.5mm G,Q,R
600x2400x12.5mm G,Q,R
625x625x12.5mm G,Q,M,R
625x1250x12.5mm G,Q,ROthersizesonrequest
SurfaceUntreated
PerforationGlobe:9-11%Quadril:10.6-14%Micro:9.5-10.7%Tangent:21.1-21.3%
AlsoavailableasRegula.Otherperforationpatternsaremanufacturedtoorder.
Globe,Ø6mm,15mmc/c
Quadril,12x12mm,30mmc/c
Micro,3x3mm,8.3mmc/c
Tangent,4x14mm,10/20mmc/c
169-168
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,70 0,80 0,75 0,60 0,500,35
α 0,65 0,75 0,70 0,65 0,500,40
α 0,65 0,70 0,65 0,60 0,600,40
α 0,70 0,95 0,95 0,85 0,850,35
α 0,15 0,05 0,05 0,05 0,050,30
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
lightreflectionDependsonthepaintusedonsite.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
FireclassFull-perforated:A2-s1,d0Part-,non-perforated:A2-s1,d0
FireratingClass1;K110,A2-s1,d0;BD30
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
tectopanel
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Globe 8.9 9.7
Quadril 8.8 9.6
Micro 8.9 9.7
Tangent 8.8 9.6
Regula 9.7 10.5
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,65mminstallationdepth,50mmmineralwool αw:0.65,NRC:0.70
Quadril,65mminstallationdepth,50mmmineralwool αw:0.65,NRC:0.70Micro,65mminstallationdepth,50mmmineralwool αw:0.65,NRC:0.60Tangent,65mminstallationdepth,50mmmineralwool αw:0.90,NRC:0.85
Regula,65mminstallationdepth,50mmmineralwool αw:0.10,NRC:0.10
170
•
A
B
furring• Tectopanelonwalls canbe installedonwoodor
steelfurringsdependingoncurrentfireregulations.• Furringscanbeinstalledverticallyorhorizontally.• Furringsshouldbeatleast45mminwidth.• Alsoseethesection“Acoustics”onthenextpage.
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.
layout• Perforated wall panels are normally installed on
the upper section of a wall in accordance withacoustic requirementsand theshapeof theroominquestion.
• However, perforatedpanels canalsobe used tosurfaceanentirewalldependingonthedegreeofphysicalimpact.
• Follow any available drawings or divide thesurfaceofthewallsothattheperforatedmodulesarepositionedsymmetricallyintheroom.
Installation• Installthepanels.• Installthefirstrowwiththehelpofstring.• Thepanelsmustbeflushintheirownrowsandat
rightanglestotheadjacentpanels.
BestPractice:Handlingthepanelswithcarewillavoiddamageandsurfacecontaminationpriortopaintingandtherebyensureagoodendresult.
INSTAllATIONGUIDE
Fig.1
45mmZ-profile
45mmU-profile
ScrewSN3.5x30
Paneledge
legend:
A=Max.200mm B=300mm
171-170
painting• Makesurethatthefilleriscompletelydryandthe
surfaceisfreefromdust.• Primingshouldbecarriedoutinaccordancewith
thepaintmanufacturer’sinstructions.• Applythepaintwithafinemohairroller.• Makesurethatthepaintisnottoothickandavoid
applying too much paint at a time so that theacousticfeltontheperforatedpanelsisnotsealed.
• Spraying cannot be recommended as this couldinfluencetheacousticpropertiesofthepanels.
filling screw holes• Checkthatthescrewshavebeencountersunk.• Applythefirstlayeroffiller(KnaufFinishPastös).• Allowthefillertodry.• Applythesecondlayeroffiller(KnaufFinishPastös),
overfillslightly.• Allowthefillertodry.
sanding• Makesurethatthefilleriscompletelydry.• Sand with fine sandpaper until the surface is
completely smooth.Becarefulnot todamage thecardboardsurface.
acoustics• A perforated gypsum panel will lose its acoustic
functioniftheperforationsareblocked(thisappliestothefrontandbackofthepanel).
• Where applicable, a vapour barrier shouldthereforealwaysbeplacedbehindthefurringssothatitdoesnotcomeintocontactwiththebackoftheperforatedpanel.
• WheninstallingTectopanelonafixedsurfacewerecommend filling the cavity between the backof the panel and the furring with mineral wool.This is primarily to ensure low frequency soundabsorption.
tectopanel
172
DETAIlS
Tectopanel-integratedacousticwall
Zprofile
Perforatedconnector
Mineralwool
Tectopanel
Furring
Mineralwool
Tectopanel
Mitex-mitreddesignelement
Tectopanel-add-onacousticwalllining
173-172
tectopanel
Productname SAPno. Productcode WxlxH
(mm)
ScrewSN3.5x30 9275 8644932 3.5x30
ACCESSORIES
Pressthepanelagainstthetemplateusingabatten,movingitevery100mm.Securethepanelontheothersideofthetemplate.Dryingtime:1½-2hours.
laythepaneloveratemplate.Securethepanelononesideofthetemplate.
Applywateronthefrontfaceandleavefor30minutes.Ifnecessarythepanelcanbecoveredinplastictoassistthepanelinabsorbingthewater.
CURVEDPANElS
Productname SAPno. Productcode WxlxH
(mm)
Z-profile 214604 - 25x45x45x3000
Scew(SN3.5x30) 9275 8644932 3.5x30
Fillingknife 73962 - -
174
Acousticalperformanceandimpactresistanceinonesolution.Acousticceilingorwallliningwithadistinctunifiedlook.TestedinaccordancewithDIN18032(EN13964)-thetoughestrequirementsforimpactresistance.Foil-coveredsurface–easytoclean.
CONTRAPANEl/WAlllININGS
175-174
contrapanel
DesignpanelTectopanelContrapanelSolopanelStratopanelKinopanelAmfipanelAdit
Didyouknowthat…
theperforationholesingypsumboardsprovideseveralacousticaleffects:soundabsorption,sounddiffusionandsoundreflection?
levalloisPerretSportscenter,France,ContrapanelWalllinings,Globe
176
Sizes600x1200x12.5mm600x1800x12.5mm600x2400x12.5mm
SurfaceFoil-coveredwithpre-impregnatedwhitepaperGloss10TestedforchemicalresistanceinaccordancewithDIN68861,FIRABS3962andNEMAlD-3-1991
EdgeB(bevellededge)Visiblejoints
CONTRAPANElWAlllININGS
PerforationG1F:10.2%
AlsoavailableasRegula.
Globe,Ø6mm,15mmc/c
177-176
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,70 0,80 0,75 0,60 0,500,35
α 0,15 0,05 0,05 0,05 0,050,30
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflectionGlobe:74.1%Regula:86.3%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
FireclassB-s1,d0
FireratingClass1;K110,B-s1,d0;BD30
RobustnessDurable and dirt resistant surface. Productmade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
contrapanel
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Globe 8.9 9.7
Regula 9.7 10.5
Certificates• DIN4102-2FireClassification
• DanishIndoorClimatelabelling
• DeclarationofConformity(EN14190)
• MPAcertificate-impactresistance
ImpactresistanceContrapanelisespeciallydesignedtomeetthetoughrequirementsforwallandceilingliningsinfacilitiesusedintensivelyforsport,sucharesporthallsandgymnasiums.
ThepanelsshownovisibledeformationafterthetestscarriedoutinaccordancewithEN13964orDIN18032.
Contrapanelmeetsthetoughestclass3requirementsinaccordancewithEN13964forimpactresistantceilinglinings,andtheeventougherrequirementsinDIN18032forimpactresistantwalllinings,makingtheproductidealevenforhandballorhockeycourts.
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
Globe,65mminstallationdepth,50mmmineralwool αw:0.65,NRC:0.70
Regula,65mminstallationdepth,50mmmineralwool αw:0.10,NRC:0.10
178
•
A
B
layout• Perforated wall panels are normally installed on
the upper section of a wall in accordance withacoustic requirementsand the shapeof the roominquestion.
• However, perforated panels can also be used tosurfaceanentirewall,dependingonthedegreeofphysicalimpact.
• Follow any available drawings or divide thesurfaceofthewallsothattheperforatedmodulesarepositionedsymmetricallyintheroom.
• If thereareno requirementson impact resistanceinaccordancewithDIN18032-3,a furringcanbeinstalledat300mmc/cwithacorrespondingincreaseinthedistancebetweenscrews.
Installation• Alwayswear clean cotton gloveswhen handling
thepanels.• Mark the position of screws on theContrapanel.
Usethesuppliedtemplateforthisifnecessary.• Installthepanels.• Installthefirstrowwiththehelpofstring.• The perforated fields must be flush in their own
rowsandatrightanglestotheadjacentfields.• Usewhitescrews.
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.
Fig.1
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
INSTAllATIONGUIDE
45mmZ-profile
45mmU-profileScrewSN3.5x30
Paneledge
legend:
A=Max.200mm B=200mm
179-178
contrapanel
ACCESSORIES
Contrapanel-integratedimpactresistantacousticwall
Zprofile
Perforatedconnector
Mineralwool
Contrapanel
DETAIlS
Productname SAPno. Productcode WxlxH
(mm)
Zprofile 214604 - 25x45x45x3000
WhitepaintedscrewWS32T-for1layeronwood 6389 5688308 32
WhitepaintedscrewWS42T-for2layersonwood 14621 1432504 42
WhitepaintedscrewWS25S-for1layeronsteel 219774 1448934 25
WhitepaintedscrewWS38S-for2layersonsteel 219780 1448939 38
180
Continuousperforationstotheedgeofferingafluid,monolithiclook.Achoiceofseamlessordiscreetjoints.Acousticgypsumliningforceilingandwallsurfaces.
SOlOPANEl/WAlllININGS
181-180
Didyouknowthat…
22%ofgypsum’smassiswaterboundtothegypsumcrystalandensuringthefireprotectivepropertiesofgypsumboards?
solopanel
DesignpanelTectopanelContrapanelSolopanelStratopanelKinopanelAmfipanelAdit
Narud,Stokke&WiigArchitechts,lørenskogCenter,Norway,Solopanel,G12/20/66
182
1
3
5
7
2
4
6
SOlOPANElWAlllININGS
SK FF MF
Perforation EdgeSK,FF&MFSK/FF:NovisiblejointsMF:Discreetjoint
SurfaceUntreated
Perforationtype Perforationpercentage
Sizes*(mm)
SK
FF
MF
1:G8/18 15.5% 900x2700/1188x1998 1188x1998 1188x1998
2:G10/23 14.8% 897x2760/1196x2001 1196x2001 1196x2001
3:G12/25 18.1% 900x2700/1200x2000 1200x2000 1200x2000
4:G15/30 19.6% 900x2700/1200x1980 - -
5:Q8/18 19.8% 900x2700/1188x1998 1188x1998 -
6:G8/12/50 13.1% 900x2700/1200x2000 - -
7:G12/20/66 19.6% 924x2706/1188x1980 1188x1980 1188x1980
*Exactpanelsizesvaryfrommodulesizesaccordingtoedgetype.
183-182
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,55 0,80 0,80 0,70 0,750,30
α 0,55 0,70 0,70 0,60 0,500,35
α 0,55 0,80 0,85 0,60 0,650,30
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,55 0,70 0,75 0,65 0,650,35
α 0,55 0,70 0,70 0,60 0,650,35
α 0,55 0,75 0,80 0,70 0,600,30
α 0,55 0,80 0,80 0,65 0,650,30
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
lightreflectionDependsonthepaintusedonsite.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
FireclassA2-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
solopanel
Perforation Tileweight(kg/m2)
G8/18 8.8
G10/23 8.8
G12/25 8.5
G15/30 8.4
G8/12/50 9.0
G12/20/66 8.4
Q8/18 8.3
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
G8/18,65mminstallationdepth,50mmmineralwool αw:0.70,NRC:0.65G10/23,65mminstallationdepth,50mmmineralwool αw:0.70,NRC:0.65G12/25,65mminstallationdepth,50mmmineralwool αw:0.75,NRC:0.70G15/30,65mminstallationdepth,50mmmineralwool αw:0.75,NRC:0.70
Q8/18,65mminstallationdepth,50mmmineralwool αw:0.75,NRC:0.70G8/12/50,65mminstallationdepth,50mmmineralwool αw:0.65,NRC:0.65G12/20/66,65mminstallationdepth,50mmmineralwoolαw:0.70,NRC:0.70
184
SK
SK/FF/MF
SK
•
C
layout• Perforated wall panels are normally installed on
the upper section of a wall in accordance withacoustic requirementsand the shapeof the roominquestion.
• However, perforated panels can also be used tosurfaceanentirewalldependingonthedegreeofphysicalimpact.
• Please note that expansion joints must beestablishedon extensive ceiling surfacesatmax.intervals of 15 metres in both directions. Seedetaileddrawingsatknaufdanoline.com.
positioning• SKpanelsaresuppliedundersized,andmustbe
installedatdistancesof2-5mmfromeachothertoensurethatitispossibletoinsertfillerallthewayupbetweentheedges.
• Useamountinghooktoensurethecorrectdistancebetweenperforationrowsatthejoints.
Installation• Installthepanelssothattheyallfaceinthesame
direction(redmarkagainstbluemark).• Installthefirstrowwiththehelpofstring.• FastenpanelswithScrewSN3.5x30.
preparing panels• Breakalledgeswithfinesandpaperonthefrontso
thatthecardboardcannotrise.• PrimetheedgeswithKnaufTiefengrund(universal
primer).
BestPractice:Handlingthepanelswithcarewillavoiddamageandsurfacecontaminationpriortopaintingandtherebyensureagoodendresult.
INSTAllATIONGUIDE
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.• PrimetheedgeswithKnaufTiefengrund(universal
primer).
Fig.1
45mmZ-profile
45mmU-profileScrewSN3.5x30
Paneledge
legend:
A=Max.333mm B=Max.200mmC=Max.333mm
185-184
SK/FF/MF SK/FF/MF
SK/FF SK/FF
SK/FF/MFSK/FF
solopanel
filling screw holes• Applythefiller(KnaufFinishPastös).Overfillslightly.
We recommend the use of Knauf Danogips„Acousticfillingknifeforholes“inordertoavoidfillergettingintotheperforationholes.
• Allowthefillertodry.
sanding• Makesurethatthefilleriscompletelydry.• Sand with fine sandpaper until the surface is
completelysmooth.Becarefulnot todamage thecardboardsurface.
painting• Makesurethatthefilleriscompletelydryandthe
surfaceissmoothandfreefromdust.• Primingshouldbecarriedoutinaccordancewith
thepaintmanufacturer’sinstructions.• Applythepaintwitharollersothattheacousticfelt
ontheperforatedpanelsisnotsealed.Useafinemohairroller.
• Makesurethatthepaintisnottoothickandavoidapplyingtoomuchpaintatatime.
filling• Fillthejointwithfiller(KnaufUniflot).Useajointing
gun or press the filler into the jointwith a fillingknife.Overfillslightlyandmakesurethatthefillerispressedallthewayupbetweentheedgesofthepanelsandavoidgettingfillerintheperforations.
• Press thefillerupagainby runningafingeroverthejoint.Fillagain.
• Allowthefillertodryforabout45minutes.• Removesurplusfiller.• Allowthefillertodry.• Apply the second layer of filler (Knauf Finish
Pastös).Overfillslightly.• Allowthefillertodry.
preparing Knauf uniflott filter• Prepare the filler according to the instructions on
thefillingpackage.• Fillthetubewithjointfillerwiththehelpofaputty
knife.• Attachthejointingnozzle.• Insertthetubeandnozzleintoajointinggun.
filling• Checkthatthescrewsarecountersunkandthatthe
panelsarenotpushedclosetogether.• Check that theedgeshavebeenprimedandare
freefromdust.• UseKnaufUniflottforfilling.
186
DETAIlS
Solopanel-integratedacousticwall
Zprofile
Perforatedconnector
Mineralwool
Solopanel
Jointfilling-straightedges
187-186
solopanel
ACCESSORIES
Productname SAPno. Productcode WxlxH
(mm)
Z-profile 214604 - 25x45x45x3000
ScrewSN3.5x30 9275 8644932 3.5x30
KnaufTiefengrund(UniversalPrimer) 9209 5214577 5l
KnaufPastös 9631 1468992 20kg
KnaufUniflott
2509
2507
7802739
8644932
25kg
5kg
FillerTubeset 9220 5214576 -
Fillingknife 73962 - -
Mountinghook
8/1810/2312/2515/308/12/5012/20/66
921292139214921592169217
-
2pcs2pcs2pcs2pcs2pcs2pcs
188
Continuousrandomperforationpatternofferingafluid,monolithiclook.Seamlessliningforceilingandwallsurfaces.
STRATOPANEl/WAlllININGS
189-188
Didyouknowthat…
gypsumusedformanufacturingofKnaufDanolineproductsishighgradeglassfibrereinforced?
stratopanel
DesignpanelTectopanelContrapanelSolopanelStratopanelKinopanelAmfipanelAdit
MuseumofNaturalHistory,Denmark,Straopanel
190
STRATOPANElWAlllININGS
SurfaceUntreated
SK FF
Perforation EdgeSK&FFNovisiblejoints
G8/15/20
G12/20/35
Perforationtype Perforation% Sizes*(mm)
SK
FF
G8/15/20 9.9% 1200x1875/1200x2500 1200x1875/1200x2500
G12/20/35 9.8% 1200x1875/1200x2500 1200x1875/1200x2500
*Exactpanelsizesvaryfrommodulesizesaccordingtoedgetype.
191-190
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,45 0,55 0,55 0,40 0,450,35
α 0,55 0,80 0,85 0,60 0,650,30
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
lightreflectionDependsonthepaintusedonsite.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
load-bearingcapacity2/A/Noload2/B/30N
FireclassA2-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
stratopanel
Perforation Tileweight(kg/m2)
G8/15/20 9.3
G12/20/35 9.3
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Foracousticdataonalternativeconstructionspleasesee“AbsorptionData”atknaufdanoline.com
G8/15/20,65mminstallationdepth,50mmmineralwool αw:0.50,NRC:0.50
G12/20/66,65mminstallationdepth,50mmmineralwoolαw:0.70,NRC:0.70
192
•
A
B
C
BestPractice:Handlingthepanelswithcarewillavoiddamageandsurfacecontaminationpriortopaintingandtherebyensureagoodendresult.
INSTAllATIONGUIDE
cutting• Cuttheelementstosizefromthefrontwithafine-
toothedsaw.• PrimetheedgeswithKnaufTiefengrund(universal
primer).
layout• Perforated wall panels are normally installed on
the upper section of a wall in accordance withacoustic requirementsand the shapeof the roominquestion.
• However, perforated panels can also be used tosurfaceanentirewalldependingonthedegreeofphysicalimpact.
• Please note that expansion joints must beestablishedon extensive ceiling surfacesatmax.intervals of 15 metres in both directions. Seedetaileddrawingsatknaufdanoline.com.
Installation• Installthepanelssothattheyallfaceinthesame
direction(redmarkagainstbluemark).• Installthefirstrowwiththehelpofstring.• FastenpanelswithScrewSN3.5x30.
preparing panels• Breakalledgeswithfinesandpaperonthefrontso
thatthecardboardcannotrise.• PrimetheedgeswithKnaufTiefengrund(universal
primer).
Fig.1
45mmZ-profile
45mmU-profileScrewSN3.5x30
Paneledge
legend:
A=Max.333mm B=Max.200mmC=Max.333mm
193-192
stratopanel
filling• Checkthatthescrewsarecountersunkandthatthe
panelsarenotpushedclosetogether.• Check that theedgeshavebeenprimedandare
freefromdust.• UseKnaufUniflottforfilling.
filling screw holes• Applythefiller(KnaufFinishPastös).Overfillslightly.
We recommend the use of Knauf Danogips„Acousticfillingknifeforholes“inordertoavoidfillergettingintotheperforationholes.
• Allowthefillertodry.
sanding• Makesurethatthefilleriscompletelydry.• Sand with fine sandpaper until the surface is
completelysmooth.Becarefulnot todamage thecardboardsurface.
painting• Makesurethatthefilleriscompletelydryandthe
surfaceissmoothandfreefromdust.• Primingshouldbecarriedoutinaccordancewith
thepaintmanufacturer’sinstructions.• Applythepaintwitharollersothattheacousticfelt
ontheperforatedpanelsisnotsealed.Useafinemohairroller.
• Makesurethatthepaintisnottoothickandavoidapplyingtoomuchpaintatatime.
filling• Fillthejointwithfiller(KnaufUniflot).Useajointing
gun or press the filler into the jointwith a fillingknife.Overfillslightlyandmakesurethatthefillerispressedallthewayupbetweentheedgesofthepanelsandavoidgettingfillerintheperforations.
• Press thefillerupagainby runningafingeroverthejoint.Fillagain.
• Allowthefillertodryforabout45minutes.• Removesurplusfiller.• Allowthefillertodry.• Apply the second layer of filler (Knauf Finish
Pastös).Overfillslightly.• Allowthefillertodry.
preparing Knauf uniflott filter• Prepare the filler according to the instructions on
thefillingpackage.• Fillthetubewithjointfillerwiththehelpofaputty
knife.• Attachthejointingnozzle.• Insertthetubeandnozzleintoajointinggun.
194
DETAIlS
Stratopanel-integratedacousticwall
Zprofile
Perforatedconnector
Mineralwool
Stratopanel
Jointfilling-straightedges
195-194
stratopanel
ACCESSORIES
Productname SAPno. Productcode WxlxH
(mm)
Z-profile 214604 - 25x45x45x3000
ScrewSN3.5x30 9275 8644932 3.5x30
KnaufTiefengrund(UniversalPrimer) 9209 5214577 5l
KnaufPastös 9631 1468992 20kg
KnaufUniflott
2509
2507
7802739
8644932
25kg
5kg
FillerTubeset 9220 5214576 -
Fillingknife 73962 - -
196
Specialacousticwallliningforcinemasandotherentertainmentpremisesrequiringexcellentsounddiffusion.Discreetunifiedlookwithelegantovalperforations.
KINOPANEl/WAlllININGS
197-196
Didyouknowthat…
perforatedgypsumboardsusesoundresonanceorcounter-soundtoenhancesoundabsorption?
KInopanel
DesignpanelTectopanelContrapanelSolopanelStratopanelKinopanelAmfipanelAdit
FuggibaggiDesign,BergenKino,Norway,Kinopanel
198
53
60
Sizes600x600x12.5mm
SurfaceStandardblackpaintedsurfaceNCSS9000-N(gloss5)Robust,dirtresistantandexceptionallyeasytoclean.Othercoloursavailableonrequest.EJOINTS
EdgeBBevellededgeVisiblejoints
KINOPANElWAlllININGS
PerforationKino:36.9%
Kinoperforationisaspecialperforationdesignedforcinemasandotherentertainmentpremises.
Kino,8x53mm,15/60mmc/c
199-198
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,90 0,80 0,70 0,750,55
α 0,85 0,90 0,85 0,80 0,850,80
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
FireclassFull-perforated:A2-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
KInopanel
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Kino 6.2 8.0
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
ACCESSORIES
Productname SAPno. Productcode WxlxH
Rubberplug 9104 - -
ScrewSN3.5x30 9275 8644932 3.5x30mm
Kinofelt 9521 - 1.28x100m
Fireprotectivefurring
7876 -
50x1800x20mm120x1800x20mm120x215x20mm120x480x20mm
Kino,85mminstallationdepth,50mmmineralwool αw:0.80,NRC:0.75
Kino,135mminstallationdepth,50mmmineralwool αw:0.85,NRC:0.85
200
•
A
B
C
cutting • Fix50x50mmor50x100mmwoodenfurring
verticallyat600mmintervals.• The furringmustbeplaced verticallyprecisely in
relationtothejointbetweenthepanels.
Installation of horizontal furring • Usespecialfireprotectivefurring.• Screw fix 20 x 120 mm fire protective furring
horizontallyat600mmintervals(thefurringmustbeplacedpreciselyinrelationtothejointbetweenthepanels).
• Up to 1800 mm above the floor fix additionalhorizontal fire protective furring 20 x 50 mmmidwaybetweenthemainhorizontalfurring(thefurringmust be placed in relation the centre ofthepanel).
Installation of vertical furring• Fix vertical fire protective furring 20 x 120 mm
directly on top of the primary vertical woodenfurring,betweenthehorizontalfurring.
• It is important that the furring is installed in thisway tomake a plane support framework for theKinopanels.
Insulation• Placemineral wool (stonewool 30-40 kg/m³ or
glasswool20-25kg/m³)betweenthefurring.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandawallwithoutfingermarks.
INSTAllATIONGUIDE
Fireboardstrip
Battens
ScrewSN3.5x30
Paneledge
legend:
A=600mm B=300mmC=300mm
201-200
Installation of frieze• If a frieze is to be installed, it is important that
the frieze opening is at right angles and madeprecisely in relation to thenumberofKinopanelstobeinstalled.
• The frieze shouldbe installed, filledandpaintedpriortoinstallationoftheKinopanel.
fixing of Kino felt• StapletheKinofelttothefurringintheareawhere
theKinopanelsaretobeinstalled.
Installation of panels• Kinopanel is fixed on all four sides at 300 mm
distances(i.e.8screwsper600x600mmpanel)• Mount acoustic rubber plugs in the perforation
slots of the panel and screw through the plugswithKnaufDanolinescrewSN3.5x30,sothattheKinopanelissecurelyfixedtotheframework.
KInopanel
DETAIlS
Kinopanelonfurring
Fireboardstrip
Kinofelt
Mineralwool
Kinopanel
Rubberplug
Furring
202
Specialacousticwallliningforcinemasandotherentertainmentpremises.Discreetunifiedlookwithelegantovalperforations.Goodsounddiffusivepropertiespreventingechoesandensuringacousticcomfort.
AMFIPANEl/WAlllININGS
203-202
Didyouknowthat…
KnaufDanolineproductsaretestedforindoorairqualityaccordingtoDanishIndoorClimatelabelling;andthattheyareplacedinbestcategorywithlowparticleemissionandanindoorvalueof10days?
amfIpanel
DesignpanelTectopanelContrapanelSolopanelStratopanelKinopanelAmfipanelAdit
Kosmorama,Denmark,Amfipanel,Tangent
204
Sizes600x600x12.5mm600x900x12.5mm
SurfaceStandardblackpaintedNCSS-9000-N(gloss5)Othercoloursavailableonrequest.
AMFIPANElWAlllININGS
PerforationTangent:22.9%
AlsoavailableasRegula.
EdgeB(bevellededge)Visiblejoints
Tangent,4x14mm,10/20mmc/c
205-204
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,60 1,00 0,85 0,80 0,750,25
α 1,00 0,95 0,95 0,85 0,750,60
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
lightreflection5.5%
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
FireclassFullperforated:A2-s1,d0
FireratingClass1;K110,A2-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
amfIpanel
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Kino 7.2 9.0
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
Tangent,85mminstallationdepth,50mmmineralwool αw:0.85,NRC:0.80
Tangent,135mminstallationdepth,50mmmineralwool αw:0.90,NRC:0.95
206
•
A
B
furring• Fix50x50mmor50x100mmbattensverticallyat
600mm(Amfipanel600)or900mm(Amfipanel900)intervals.
• Thebattensmustbeplacedverticallyprecisely inrelationtothejointofthepanels.
Installation of vertical furring• Fix 22x60 mm planed battens on top of the
primary furringat600mmc/c (Amfipanel600)or900mmc/c(Amfipanel900).
• It is important that the vertical battens areperpendicular to and flush with the horizontalbattens,sothatthefurringstructureiscompletelyplane.
Insulation• Place mineral wool (stone wool 30-40 kg/m³ or
glasswool20-25kg/m³)betweenthebattens.
Installation of horizontal furring• Fix22x60mmplanedbattenshorizontally to the
furringat600mmc/c.• Itisimportantthatthebattensaremountedprecisely
andperpendicularly.
Fig.1
INSTAllATIONGUIDE
legend:22x60mmfurring
Battens
BlackScrewGG38
PaneledgeA=600mmB=600mm
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
207-206
Installation of panels• Fix theAmfipanels to the furring through thepre-
boredholes.• Useblackscrews(min.32mm)andGG38.
fixing of felt• SecuretheKinofelttothefurringintheareawhere
Amfipanelistobemounted.
Installation of possible frieze• Ifafriezeistobeinstalled,itisimportantthatthe
openingbetweenthefriezesisperpendicularandpreciselyadjustedtothequantityofAmfipanels.
• Install and paint the frieze before installing thepanels.
amfIpanel
208
DETAIlS
Amfipanelonfurring
Furring
Kinofelt
Amfipanel
Mineralwool
209-208
amfIpanel
ACCESSORIES
Productname SAPno. Productcode WxlxH
GG38 22109 - 3.8x38
Kinofelt 9521 - 1.28x100m
210
ADIT/WAlllININGS
Highlyeffectiveacousticpost-adjustmentinexistingrooms.Exceptionallyfastandeasyinstallation.Minimumdisturbanceofthedailyactivitiesintheroom.Easycleaningandmaintenancethankstothefoil-covered,robustsurface.
211-210
Didyouknowthat…
thecardboardingypsumboardsisproducedof100%recycledcelluloseheldtogetherbynaturalstarchagents?
aDIt
DesignpanelTectopanelContrapanelSolopanelStratopanelKinopanelAmfipanelAdit
SkørpingSchool,Denmark,Adit,Tangent
212
Sizes450x2400x9.5mm
SurfaceFoil-coveredwithpre-impregnatedwhitepaperNCSS0300-N(RAl9016,gloss10)
FoiltestedforchemicalresistanceinaccordancewithDIN68861,FIRABS3962andNEMAlD-3-1991
ADITWAlllININGS
PerforationTangent:24.5%
EdgeB(bevellededge)Mitredandgluedlongedges
Tangent4x14mm,10/20mmc/c
213-212
1,0
0,8
0,6
0,4
0,2
0,0
α
Hz400020001000500250125
α 0,65 0,90 0,90 0,85 0,800,25
1,0
0,8
0,6
0,4
0,2
0,0
s
Hz400020001000500250125
s 0,77 0,78 0,76 0,64 0,730,87
s 0,57 0,62 0,56 0,53 0,570,73
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampcloth using normal cleaning practices andneutralcleaningsolutions.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat90%RHand30°C.Theproductcanwithstandambienttemperaturesofupto50°C.
FireclassFull-perforated:B-s1,d0
RobustnessDurable and dirt resistant surface. Productmade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductpropertiesarepreserved.
aDIt
Perforation Tileweight(kg/m2)
Transportationweight(kg/m2)
Installedweight(kg/m2)
Tangent 8.0 11.8 12.1
Certificates• DeclarationofConformity
(EN14190)
• DanishIndoorClimatelabelling
ACOUSTICS
ReverberationtimeMeasurementbeforeandafterAdit
Tangent,55mminstallationdepth,33mmmineralwool αw:0.90,NRC:0.85
BeforeAdit0,76s
AfterAdit0,60s
214
A
z-profiles• Install the Z profiles horizontally. Choose the
methodofsecuringtheanglesinaccordancewiththesubstrate.
• ThelargeflangeontheZprofilesmustbesecuredtothewall.
• When installing several Adit elements incontinuationofeachotheritwillbeanadvantagetostaggerthejointsoftheuppermostZprofilesbyhalfalengthinrelationtothejointsoftheelementsinordertoensurethattheelementsarelevel.
measuring• Use the gypsum template supplied to mark the
positionsoftheZprofiles.
INSTAllATIONGUIDE
end cover• Whereelementsdonotrunfromwall towall,use
theendcoverssuppliedtocoverthemineralwoolatthevisibleends.PushtheendcoverbehindtheZprofilesandsecurewithascrewthroughthepre-boredhole.
BestPractice:Useofcleancottongloveswhenhandlingproductelementswillensureagoodresultandaceilingwithoutfingermarks.
legend:
22x60mmfurringPaneledge
A=Min.55mm
Fig.1
215-214
aDIt
end profile• WhereendcoversareinstalledtheassociatedAdit
elementsshouldbecappedwithanendprofile.• Pushtheendprofileovertheendoftheelement.• The smallest flange must cover the front of the
element.• locktheendprofileinplaceusingtheendprofile
clip.
securing• locktheelementinpositionatthebottomwiththe
helpoftheholddownclipssupplied.
Danopor• Install the plastic-wrappedmineralwool between
theZprofiles.
cutting• Cut theelements tosize from the frontwithafine-
toothedsaw.
Installation• TilttheAditelementoverthetopprofile.
Installation• lowertheelementoverthetopprofile.• The element is now in position but can still be
adjustedlongitudinally.• Elements shouldbebuttedup tooneanother/the
adjacent wall. Where the elements stop in themiddleofthewall,fitthesuppliedendcoversandprofilesasillustratedbelow.
Installation of adit panels• PushtheedgeoftheAditpanelwiththelargestfold
underthelowerprofileandpressitupwards.
216
DETAIlS
Adit
Zprofile
Holddownclip
Endcoverprofile
Endprofile
Danopor
Adit
217-216
aDIt
ACCESSORIES
Productname SAPno. Productcode WxlxH
Z45profile 14380 - 45x2300
Endcoverprofile - 215384 -
Endprofile 14585 - 25x32/7.5x450
Danopor - - 33x350x575
Measuringtemplate - - 55x356.5
Holddownclip 3382 5688307 -
Endprofileclip 3380 5973227 -
218
Countlesspossibilitiestocreateyourownshapes.Precise,knife-sharpedging.Opportunitytoplaywithgypsumlikeplayingwithpaper.
MITEx/DESIGNElEMENTS
219-218
Didyouknowthat…
KnaufDanolineispartoftheworldwideKnaufGroup-oneofthemostimportantsuppliersofconstructionmaterialsintheworld?
panels
MitexCurvex
WingårdhArchitectOffice,AstraZenecaTinghuset,Sweden,Mitex
220
max. 1050 mmmax. 1050 mm
max. 1200 mm
150°
30°
90° 90°
45°135°
SizesThickness:9or13mmMax.widthofboard:1200mmMax.widthfromedgetofurthestcut:1050mmMax.lengthofboard:3000mmMin.lengthofboard:200mmandmin.1/3oftheboard'swidth
AnglesStandardangle 90°Min.angle 30°Max.angle 135°
Anglesfrom30°upto90°andfrom90°to135°uponrequest.Pleasecontactoursalesdepartmentforfurtherdetails.
Forallanglesbeloworabove90°adrawingmustaccompanytheorder.
30°Mitex
90°Mitex
135°Mitex
MITEx
221-220
mItex
SurfaceStandarduntreated
PerforationSuppliednon-perforatedCustomisedperforationdesignonrequest.
InstallationGluetheelementstoshapebyapplyingsilicategluetotheV-cutsimmediatelybeforeinstallationofMitex.
Thesupportmustbelevel.MaximumdistancebetweenthesupportsdependsontheshapeandtheapplicationoftheMitexelement.TheMitexelementsarescrew-fixeddirectlythroughthepanel.
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
FireclassA2-s1,d0
FireratingClass1;K110,A2-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
ACCESSORIES
Productname SAPno. Productcode
MultiGlue 15612 1490935 310ml
222
Archesboundedonlybythelimitsoftheimagination.Organicdesignwithdifferentedgesadaptabletoalltypesofceilingandwalldesigns.
CURVEx/PANElS
223-222
Didyouknowthat…
innature,whenlimestoneandsmokeparticlesfromvolcanoscomeincontactwithwater,thecrystalCaSO4+H2Oisproduced?TheBeerenbergvolcanoonJanMeyenisthereasonforlargequantitiesofnaturalgypsumaroundtheworld.
panels
MitexCurvex
DidierNoëlPetit,lyonHospital,France,Curvex
224
A
B
SizesMin.radius:25mmMin.length:200mmMax.length:3000(typeA)Min.thickness2x6mmCirclecut:0°-180°
Radiiunder80mm(internally)aregroovecutRadiiunder120mm(internally)mustbefilledcompletely.
Edges
Extensionsareoptionalandareusedforjointfilling.Foroptimalresult,werecommendextensionsiftheCurvexelementsaretobeconnectedwithregulargypsumboards.
Edge End Side
Squareedge E1 S1
Squareedge25mmstaggered
E2 S2
Squareedge50mmstaggered
E4
Bevellededge E7
Bevellededge50mmstaggered
E8
End
Side
Extension
length
90°internal
180°internal 180°external
90°external
A B
Curvelength(mm) 200-3000 900 1200
Angle 90° 180° 90° 180° 90° 180°
Thickness(mm) 131825 131825 131825
Radius(m
m)
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
CURVEx
Thecolumncladdingissuppliedin4nos.180°shells,eachconsistingof2x6mmgypsumboards:• 2shellsfor1stlayer• 2shellsfor2ndlayerThesecondlayertobeinstalled90°staggered.
S-shapedcurvesareproducedtocustomerspecification.Drawingmustbesupplied.PleasecontactKnaufDanolineformoreinformation.
200-1200mmPanelwidth
200-3000mmPanellengthCurvelength
200-1200mmPanelwidthCurvelength
1200-3000mmPanellength
A
225-224
curvex
DanishIndoorClimatelabelling(DIM)Indoorvalue:10daysParticleemission:low(<0.75mg)
CleaningDustisremovedusingadrydusterorvacuumcleaner. Removal of marks depends on thepaint used on site, although a damp clothusing normal cleaning practices and neutralcleaning solutions is normally suitable forminor marks. In the case of stubborn marksorifindoubtrefertothepaintmanufacturer’srecommendations.
AmbientconditionsThe product is designed to perform undernormal conditions of use. Testedat70%RHand25°C.Theproductcanwithstandambienttemperaturesofupto50°C.
FireclassA2-s1,d0
RobustnessMade of robust, glass fibre reinforcedmaterial with excellent pressure resistance.Under normal conditionsof use, theproductproperties are preserved and there is nodecompositionofmaterialovertime.
InstallationCurvexelementsmustbemountedonastablesupport.Securetheelementstothesupportatamax.screwdistanceof300mminbothdirections.Bothendsofthecurvemustbesecured.
Asageneralrule,theCurvexelementsarescrewfixedthroughtheboard.IftheCurvexelementswithbevellededgesareused,pushtheelementsclosetogether.
Iftheelementsontheotherhandrequirejointfilling,leaveaspaceof2-4mmbetweentheelements.BeveloffsquareedgesandprimethemwithKnaufprimer.
KnaufDanolinerecommendsKnaufUniflottfillerforjointfilling.
SurfaceStandarduntreated
PerforationSuppliednon-perforatedForperforatedcurvedpanels,pleaseseeDesignpanelandTectopanel
226
PERFORATIONS
ThedifferentperforationsensureacousticalperformanceofandgiveidentitytoKnaufDanolineproducts.Eachperforationhasitsowncharacteristicsfromtheorganiclookofroundholes,togrid-likelookofthemicrosquareholes,tothemaritimelookoflargesquareholesorthetechnicallookoflargeovalholes.
227-226
NathalieWolff,Builder,PharmaciedeBeure,France,Belgravia,Quadril
perforatIons
Unity6TangentMicroQuadrilGlobeKinoSoloStrato
Didyouknowthat…
thedepthofthecavitybehindtheperforatedgypsumboardisdecisiveforsoundabsorbingpropertiesofthematerial?
228
1515 6
AC D
B
14
20
410
A
C D
B
Unity6(U6)perforationpatternsconsistof6mmcircularholesat15mmc/cand15/12.5mmtotheedgeofthetile.
Tangentperforationpatternsconsistof4x14mmovalholesat10/20mmc/c.
TANGENT Perforationpercentage A B C D
Products
Vista 21.3% 22.5 330 40 1120
Contur 19.7% 45 510 50 500
BelgraviaS24 21.3% 27 530 32 520
MarkantS24 19.7% 32.5 510 37.5 500
Plaza 21.3% 32 530 37 520
Corridor 21.6% 35 330 30 1140/1440/1740/2040/2340
Tectopanel 21.3% 35 530 40 520
Danopanel 21.3% 35 530 40 520
Amfipanel 22.9% 25 550 30 540
Adit 24.5% 15 420 40 2320
U6
TANGENT
Unity6 Perforationpercentage A B C D
ProductsSystem 11.95% 15 570 15 570
Bridge 12% 12.5 375 22.5 1155/1455/1755/2055/2355
A/C:Distancebetweentheedgeofthetileandthecentreofthe1stperforationrow.B / D: Size of the perforation field from thecentreofthe1stperforationrowtothecentreofthelastperforationrow.
229-228
3 8.3
3
A
C D
B
12
30
12
A
C D
B
Microperforationpatternsconsistof3x3mmsquareholesat8.3mmc/c.
Quadrilperforationpatternsconsistof12x12mmsquareholesat30mmc/c.
QUADRIl Perforationpercentage A B C D
Products
Contur 13% 45 510 45 510
BelgraviaS24 13% 37 510 37 510
linear 10.2% 71 450 71 450
MarkantS24 13% 32.75 510 32.75 510
Plaza 13% 42 510 42 510
Corridor 14.2% 35 330 30 1140/1440/1740/2040/2340
CorridorSwing 11.5% 62.75 450 62.75 1050
CorridorF30 12.3% 45 225 20 2760
Tectopanel 13% 45 510 45 510
Danopanel 13% 45 510 45 510
MICRO
QUADRIl
MICRO Perforationpercentage A B C D
ProductsContur 10.2% 37.5 510 37.5 510BelgraviaS24 10.2% 29.5 525 29.5 525linear 10.2% 33.5 525 33.5 525MarkantS24 10.2% 25.25 525 25.25 525Plaza 10.2% 34.5 525 34.5 525Corridor 10.6% 37.5 325 25 1150/1450/
1750/2050/2350CorridorSwing 9.9% 41.9 491.7 41.9 1091.7CorridorF30 9.8% 37.5 225 20.89 2758.22Tectopanel 10.2% 37.5 525 37.5 525Danopanel 10.2% 37.5 525 45 510
perforatIons
A/C:Distancebetweentheedgeofthetileandthecentreofthe1stperforationrow.B / D: Size of the perforation field from thecentreofthe1stperforationrowtothecentreofthelastperforationrow.
230
15 6
15
A
C D
B
Globeperforationpatternsconsistof6mmcircularholesat15mmc/c.
Kinoperforationconsistsof8x53mmovalholesat15/60mmc/c.
Kinoperforationisespeciallydesignedtodiffusesound in cinemas and other entertainmentpremises.
GlOBE Perforationpercentage A B C D
Products
Contur 10.2% 37.5 525 37.5 525
BelgraviaS24 10.2% 29.5 525 29.5 525
linear 9.1% 48.5 495 48.5 495
MarkantS24 10.2% 25.25 525 25.25 525
Plaza 10.2% 34.5 525 34.5 525
Corridor 10.6% 35 330 30 1140/1440/1740/2040/2340
CorridorSwing 10% 40.25 495 40.25 1095
CorridorF30 9.8% 37.5 225 20 2740
Tectopanel 10.2% 37.5 525 37.5 525
Danopanel 10.2% 37.5 525 37.5 525
A B C D E
Contrapanel 10.2% 37.5 525 37.5 525 75
GlOBE
KINO
Perforationpercentage A B C D36.9% 60 480 37.5 525
A / C: Distance between the edge of the tile and the centre of the 1stperforationrow.
B/D:Sizeoftheperforationfieldfromthecentreofthe1stperforationrowtothecentreofthelastperforationrow.
231-230
G8/18
G15/30
G8/12/50
G10/23
Q8/18
G12/25
G12/20/66
G8/15/20 G12/20/35
Stratoperforationcomesintwodifferentperforationdesignswitharandomsequenceofroundholesinthreedifferentsizes,viz.8/15/20mmand12/20/35mm.
Soloperforationcomesinsevendifferentperforationsdesignsinafixed,uniformsequence:• 8,10,12and15mmroundholesinuniformsequence• 8mmsquareholesinuniformsequence• 8/12mmand12/20mmstaggeredroundholesinuniformsequence
SOlO
STRATO
perforatIons
232
PROPERTIES
KnaufDanolineproductscreateindoorcomfortfortheoccupantsofthebuildingbyprovidingexcellentacousticenvironment,highairquality,pleasantlightreflectionandclassic,timelessaesthetics.Theyareenvironmentallyresponsibleandsustainablematerialsthatcanlastthelifetimeofthebuilding.
233-232
AcousticsAirqualityCleaninglightreflectionAmbientconditionsload-bearingcapacityFiresafetyRobustnessEnvironmentColoursWarrantyUpkeep&maintenance
VaiklaDisainAS,DorpatHotel,Estonia,Curvex,Quadril
Didyouknowthat…
thediffusionofperforatedgypsumboardsisbeneficialtospeechintelligibilityinaroom?
propertIes
234
With Knauf Danoline acoustic materials it is possible to create acoustic solutionsthatalwaysmeet your nationalacoustic requirements for specific reverberation time.Dependingontheconstructionoftheceilingandtheperforationdesign,certainKnaufDanoline products can absorb up to 90% of the sound that hit the ceiling surface.
WhencalculatingtheamountofKnaufDanoline’sacousticmaterialsnecessarytomeetagivenreverberationtime,itisimportanttoconsider:• thetotalceilingconstructionwhichtheacousticmaterialswillbepartof;• theshapeoftheroomandplacementofacousticmaterials• theamountoffurnitureenteringintothefinishedroom• thepurposeoftheroom
Did you know that KnaufDanoline products can berepaintedtimeaftertimewithoutany loss of their acousticproperties?
Thepurposeoftheroomisdecisivefortheacousticenvironmenttobecreated.Inroomsforspeech,suchas classrooms and auditoriums, it is important toensureagood level of sound spreading,whereasroomsforconcentratedworkrequireahighlevelofabsorption.
Furniture represents acoustic materials in itself. Inorder to avoid too much sound absorption, whichcan cause acoustic discomfort just like too littleabsorption, it is important to take into account theamountoffurnishings.
Theshapeoftheroomdefinesthemovementofthesoundwaveswithintheroom.Placementofacousticmaterialsshouldbedeterminedbythewaythesoundmoves in that particular room in order to ensureoptimalefficiencyofthematerials.
Theacousticmaterialscombinedwith thesystemonwhichtheyareinstalledformtheacousticconstructionthat absorbs sound. Thus, the amount of soundabsorbed depends on the installation depth of theceiling and whether or not the cavity is filled withmineralwool.
ACOUSTICS
235-234
ThehardeningofgypsumboardsusedforthemanufacturingofKnaufDanolineproductsisbasedpurelyonreactionswithwater,andcontains thereforenovolatile liquidsorsuchlike.Thus,theuseofKnaufDanolineproductscausesnohealthnuisances.
AllsurfacefinishesusedonKnaufDanolineproducts(i.e.highandlowglosspaintanddifferent foils)arealsoclassifiedasnon-hazardousandforreasonsof indoorclimatesafetyandconsiderationfortheenvironment,therearenoaddedbiocidesthatgiveanactivebiocidaleffectwithinoronthefinishedsurfacefilm.
Danish IndoorClimate labelling is a voluntary labelling scheme, the first one in theworldtorateconstructionmaterialsaccordingtotheirindoorclimatepropertiesduringtheservicephase.
Theratingcoversdegassingwithatimevalueindays,andparticleemission,basedonthereleaseofparticlesfromsedimentabledust.
KnaufDanolineproductshavethefollowingclassifications:• Indoorclimatevalue:10days• Particleemission:lOW(<0.75mg)
KnaufDanolineproductsareadditionallyratedaccording to theSwedishSundaHuslabelling-anoverallassessmentoftheproduct’senvironmentalandhealthimpacts,fromitsorigintoitsdisposal:• Untreatedandpaintedproducts:ClassA• Foil-finishedproducts:ClassB
Knauf Danoline products are recommended by the Swedish Byggvarubedömningen,anassociationgatheringthelargestpropertycompaniesandinvestorsinSwedenwiththe viewof establishing a common standard for buildingmaterials by assessing thechemicalcontents,thelifecyclecriteriaandthepossibleeffectsonindoorclimateofabuildingmaterial.
All KnaufDanolineproducts tolerate normal cleaningpracticesandneutral cleaningsolutions.Dustcanberemovedbyadrydusteroravacuumcleaner.Removalofmarkscanbecarriedoutwithadampcloth.
Danotile-hygieneceiling-isabletowithstandtoughcleaninganddisinfectionagentswithpHfrom2to13.Danotileisclean-roomcertifiedandcanbeusedinroomsrequiringhighinfectioncontrolsuchaslaboratories,kitchens,slaughterhouses,etc.
DanotileachievessilverclassificationinExcell,andisclassifiedasISO5inaccordancewithISO14644-1.
AIRQUAlITY
ClEANING
propertIes
236
ThepaintonKnaufDanolineproductshasalowglossvaluewhichensuresgoodlightspreading -apropertywhich issustainedover time.For thefinishedKnaufDanolineproducts, the light reflectance values are influenced by the product’s perforationdesign,thecolourandglossvalueofthefactorypaint.Foruntreatedproducts,thelightreflectancevaluesaredeterminedbythepaintappliedonsite.
lightreflectionrequirementsdependsontheactivityintheroom.Forofficieswithdirectlightingtheminimumrequirementsis70%.
lIGHTREFlECTION
Perforation Colourpaint Gloss Glossonsubstrate
Reflectance
TangentT1 Standardwhite Gloss5 Gloss2 70.9%
MicroM1 Standardwhite Gloss5 Gloss2 72.1%
QuadrilQ1 Standardwhite Gloss5 Gloss2 75.1%
GlobeG1 Standardwhite Gloss5 Gloss2 72.8%
RegulaRplain Standardwhite Gloss5 Gloss2 82.6%
GlobeG1 Standardwhite Gloss15 Gloss10 71.5%
RegulaRplain Standardwhite Gloss15 Gloss10 80.8%
RegulaRplain Whitefoillaminated
Gloss10 Whitefoil 86.3%
237-236
ThebreakingloadtestinaccordancewithEN14190ensuresthattheproductscanbear5timestheirownweight.Thismeanse.g.anon-perforatedBelgraviatileistestedwithaloadofupto17kgwithoutanydamagetothetile.Thepurposeofthetestistosecurethestabilityoftheceiling.
However,themaximumweightoffittingsthatcanbeincorporatedinatileinpracticeis specified for each product and determined as 2½ times own weight, based onthemaximumdeflection in accordancewith EN13964. The load capacity tests theproducts'visualdeflectionandisexpressedasacombinationofthedeflectionclasses,thehumidityclasses,thenetweightandthebuilt-inweight.Thesecanbefoundundereachproduct.
DeflectionclassesClassConditions
KnaufDanolineproductsaretestedforresistancetomoistureinservice.Productstestedfor resistanceup to70%RHat25ºCaredesigned for useundernormal livingandworkingconditions,i.e.inoffices,institutionsandsimilarpremises.
Productstestedforresistanceupto90%RHat30ºCaredesignedforuseundermoreextremeconditionsandcanthusbeusedinhighhumidityroomsandroomswithfrequentandmajorchangesinthehumidityoftheair.Ingeneralwhereverpeoplecanbe,socangypsum,excessivelevelsofhumiditycombinedwithveryhightemperaturesarenotcomfortableconditionsforhumans,andinevitablyshortenthelifeofnaturalmaterials.
Howeveratlowerrelativehumiditygypsumisabletotoleratemuchhighertemperatures.Gypsumcanthereforealsobeusedinbuildingswheretemperaturescanfluctuateupto50ºCforshorterperiodsoftime.
Class Conditions
A Buildingstructuresexposedtoamax.RHof70%andamaximumtemperatureof25°C
B Buildingstructuresexposedtoamax.RHof90%andamaximumtemperatureof30°C
Class Max.deflectioninmm
1 l/500andnotmorethan4mm
2 l/300
3 Nolimitations
listheshortestdistancebetweenthesupportingprofiles.Fora600modulethemaximumdeflectionforclass1is2mmand2mmforclass2
AMBIENTCONDITIONS
lOAD-BEARINGCAPACITYpropertIes
238
KnaufDanolineceilingandwallproductsmeetallthenecessaryfiresafetyrequirements:
MaterialclassesaccordingtoEN13501-1• A2-s1,d0 Whitepaintedceilingtileswithperforationareaof10-40% Untreatedperforatedandnon-perforatedliningpanels• B-s1,d0 Foillaminatedceilingtiles Whitepaintedceilingtileswithperforationareaof<10%
MaterialclassesaccordingtoASTME84• ClassA Whitepaintedceilingtiles,perforatedandnon-perforated Untreatedperforatedandnon-perforatedliningpanels Foillaminatedceilingtiles
FireresistanceaccordingtoBS476-23:1987• ½hourfireresistance
Danotile6.5mm–foilfinished,non-perforated
FireresistanceaccordingtoEN13501-2andDS1052-11985• EI30(BD-30)
FireprotectionaccordingtoEN13501-2andEN141352004&DS1065-21990• K110andK210 Untreatedperforatedliningpanels
KnaufDanolineproductsaremadeofrobustmaterialwithexcellentpressureresistance.Undernormalconditionsofuse,theproductpropertiesarepreserved,andthereisnodecompositionovertime.
Foil-coveredproductshaveahighlydurableanddirtresistantsurface.
Contrapanel-impactresistantacousticalceilingandwallpanel-isspeciallydesignedtomeetthestrictestrequirementsforceilingandwallliningsinintensivelyusedfacilitiessuchas sport halls andgymnasiums.Contrapanelmeets the class3 requirements inaccordancewithEN13964 for impact resistant ceiling linings,andDIN18032 forimpactresistantwalllinings,makingtheproductsuitableforhandballandhockeycourtswherematerialsarerequiredtoabsorbsoundaswellaswithstandheavyimpacts.
FIRESAFETY
ROBUSTNESS
239-238
KnaufDanolineacousticceilingandwallmaterialsaremanufacturedfromhighgradegypsumboards,suppliedfromoursistercompany,KnaufDanogips.Thegypsumboardsaremadefromfollowinggypsumtypes:
• naturallyoccurringgypsum,foundinlargequanititiesintheground• gypsumproducedfromby-productsatlocalpowerplantsduringdesulphurisation–
achemicalprocessinwhichthesulphurdioxideisremovedusinglimestonepowdermixedwithwatertoformtheby-productgypsum
• preconsumer recycled gypsum, waste produced through our own productionprocesses
• postconsumerrecycledgypsum, isplasterboardwaste that is receivedfromGipsRecycling,aDanishcompanygatheringandrecyclinggypsumwastefrombuildingsitesaccrossDenmark
BothKnaufDanolineandKnaufDanogipsare ISOcertifiedcompanieswithconstantfocusonenvironmentalmanagementandoptimisationoftheproductionprocessestothebenefitofthelocalsurroundings,ourcustomersandtheenvironmentingeneral.KnaufDanolineproductsaredistinguishablebytheiruniquefeatures:
• naturalmaterial• longlifetimeandservicetime• re-useandrecycling• environmentallyresponsibleproduction• highqualityservicelife
Inorder toensure thepossibility thatusedKnaufDanolineproductscanberecycled,theyarepaintedwithwater-basedpaint,whichnotonlyallowsrecyclingbutalsohasnodeterioratingeffectonthehumidityregulatingpropertiesofthegypsummaterial.
Anotheressentialprerequisitefortherecyclingofgypsumboardistokeepthegypsumcorefreefromharmfuladditives.Themainbindingagentinthecoreisinfactwater.
TheacousticfeltonthebackofKnaufDanoline’sperforatedgypsumboardsismadeofcellulosewhichmakesitunnecessarytoremovethefeltbeforetherecyclingofgypsumboard.Infact,thedissolvedcellulosefeltgivesincreasedflexibilitytothegypsumboard.
The cardboard used in our plasterboard products is produced from 100% recycledsources.Thecardboardandpaperfoilsarealsoseparatedoutfromthecoregypsummaterialat the recyclingplant, so thatagreaterproportionofgypsumboardwasteisable tobe recycled. The cardboard fraction is usedasa structurematerial in theformationofcompostatKomTekEnvironmentA/SinDenmark.
EnvironmentalpolicyBased on the life cycle approach, we wish to contribute to ensuring sustainabledevelopment in the long term. We therefore work continuously on improving theenvironmentalconditionsandtopreventpollutionby:
• using environmentally responsible raw materials in the manufacturing ofourproducts• usingpackagingthatcanberecycledorutilised• optimisingtheconsumptionofenergy,rawmaterialsandpackaging• reducingthewaste• utilisingthewaste
KnaufDanoline is committed to reducingwasteand energy consumption. Therefore,investmentsaremadeeachyearinenergyandwasteefficiency.
TheguidingprincipleforthemanufacturingofKnaufDanolineproductsistokeepthebasicmaterialaspureaspossibleinordertosecurecontinuousrecycling.
ISOACCREDITATIONS&OTHERAPPlICABlECERTIFICATES:• ISO9001-Qualitymanagement• ISO14001-Environmental
management• OHSAS18001-OccupationalHealth
&Safety
lESFICHESDEDÉClARATIONENVIRONNEMENTAlESETSANITAIRES(FDES)-FrenchEnvironmental&HealthandSafetydeclarationbasedonlifeCycleAnalysis
lEEDDEClARATION
ENVIRONMENTpropertIes
240
KnaufDanolineproductsaredeliveredasstandarduntreated,whitepaintedorwhitelaminated.
Knauf Danoline also deliver products painted in NCS andRAlcolours.Productsaretypicallydippedandsprayfinished,althoughverylightcolourscanbesprayfinishedalone.
Maximumpanelsizefordippingis600x1200mm.
Productsarefinishedwithawaterbasedacrylicpaintingloss5.Due to thenatureof the substrate thefinishappearsasagloss2.
COlOURS
KnaufDanolineproductscanalsobepaintedonsiteusingashortmohairroller.Whenpaintingbyroller,onlythesurfaceofthepanelispaintedandtherewillbecontrastwiththegypsumcoreintheperforations.
Itisimportanttoavoidgettingpaintintheperforationholesasthiscanaffectsoundabsorptionandthefinishedlook.Therefore,ashort-hairedrollermustbeusedandthepaintshouldnotbetoothick.Donotoverapplythepaintintheperforatedareas.
241-240
WARRANTY
KnaufDanoline’sGuaranteeofQualityAtKnaufDanolineweareproudofourabilitytoconsistentlysupplyhighquality,gypsum-based,acousticsolutionsforthebenefitandcomfortofourcustomersandend-users.
AtKnaufDanolineweconsistentlydeliverwhatwepromise.
• Productsmanufacturedtothehighestinternationalqualitystandardsandguaranteedfreeofmanufacturingdefectsfor30years.
• Productsandsystemsthatcanwithstandthemoststringentofglobalfire,acousticandstructuraltests.
• Solutionsthatprovidedesign,indoorclimateandsustainabilityvalue.• Highqualityserviceandtechnicalsupportguaranteeingup-to-dateadviceandhelp
whateveryourneeds.• Equalservicetoeveryone.• Afastresponsetotherequestsofallcustomers
KnaufDanolinehasbeenintheconstructionindustryforover50yearsandthankstoourknow-howandaffiliationwiththeKnaufgroup,wehavetheknowledgeandcapacitythatsecuresflexibilityinourproduction,insightinthebuildingmarketrequirements,andthebasisforfurtherdevelopment.
Knauf Danoline is committed to a constant future proofing of its product range andthrough annual product reviews and product optimisation projects in R&D, KnaufDanolineprovidesadaptablesolutionsthatmatchthedifferentdemandsfromthemarket,whilstretainingtheirintrinsicabilitytolastalifetime.InthiswayKnaufDanolinecanconsistentlydeliver:
• Easytocleansolutionsthatmaintaintheiracousticandindoorclimatepropertiesfortheirentireservicelife,evenafterrepaintingtimeandtimeagain.
• Sustainablegypsumsolutionsthatcanlastthelifetimeofthebuilding.• Classic, timeless designs that maintain their aesthetical quality throughout their
entireservicelife.
Maintainingahighlevelofqualityservicetoourcustomersandotherstakeholdersisessentialtooursuccessandourabilitytodeliverwhatwepromise.Thereforeweeducateouremployeestohaveinsightinmarketsandtheskillsandcompetenciesrequiredtoensurethattheyunderstandtheneedsanddesiresofallourcustomers.Onlyinthiswaycanwebesurethatweareabletoconsistentlydeliverwhatwepromise.
propertIes
242
ProductCategory
DemountableT-gridCeilings
Products Unity6System,Vista,Contur,Belgravia,linear,Markant,Plaza Danotile
Surface Whitepainted Foilfinish
Upkeep Designedforuseundernormalconditions,i.e.upto70%RHand25°C,e.g.inoffices,institutionsandsimilarpremises.Belgravia,Markant,PlazaandDanotile600x600havealsobeentestedat90%RHat30ºCandcanbeusedundermoreextremeconditionssuchaskitchens,laboratoriesandroomswithfrequentandmajorchangesinthetemperatureandairhumidity.Specialpurpose,anticorrosiontreatedsuspensionsystemsshouldbeusedinareasofveryhighhumidity.
Cleaning Dustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampclothusingnormalcleaningpracticesandneutralcleaningsolutions.Stubbornmarksandminordamagesshouldbewipedcleanpriortorepainting.
lINEAR:Toensuregoodalignmentitisimportantthatthetilesareinstalledinthesameorientation.Thisisalsoimportantformaintenancewhenvacuumingorpainting.Alwaysensurethatwhenapplyingupward(painting)/downward(vacuuming)pressure,thatthetilesarepushed/pulledinthesamedirectionmovingawayfromthegroovededge.
Dustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampclothusingamilddetergentifnecessary.
Strongercleaningagentsmaybeusedwherenecessarytoremovestubbornmarksorwherecleaningregimesrequireit.TheproductcanalsostandrigorouscleaningwithconcentrateddisinfectantsanddetergentswithhighandlowpHvalues(13.0-2.5).
Repair Stubbornmarksandvisibledamagesandscratchesonthesurfacecanberepaired.Damagesandscratchescanbefilledandfinishedwithsandpaperpriortorepainting.WhenpaintinguseKnaufDanolinerepairpaintorsimilar(closestRAlcolour9003)andapplybypaintroller.Spraypaintingisnotrecommendedonperforatedproducts,asthereisariskofthespraypaintbeingappliedtotheacousticfeltbackingtherebyalteringtheacousticproperties.
Damagesandscratchesaredifficulttorepairandthereforeitisrecommendedtoreplacedamagedtileswithnew.
lampsuspension
DANOTIlE:Forsizesupto625x625andmin.thickness9mm,unitsofupto3kgcanbeinstalleddirectlyintothepanelwithoutreinforcement.Forlargermodulesizesandallsizesin6mmthickness,areinforcementpanelofsufficientstrengthcanbeinstalledbehindtheelement.Thereinforcementpanelmustextendallthewayintothemainrunners,sothattheweightistransferredtothem.Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeused.Unitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
BElGRAVIA,MARKANT,PlAZA,MEDlEY:Forsizesupto625x625notinTangentperforation,unitsofupto3kgcanbeinstalleddirectlyintothepanelwithoutreinforcement.ForlargermodulesizesandallsizeswithTangentperforationareinforcementpanelofsufficientstrengthcanbeinstalledbehindtheelement.Thereinforcementpanelmustextendallthewayintothemainrunners,sothattheweightistransferredtothem.Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeusedUnitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
UNITY6SYSTEM,VISTA,CONTUR,lINEAR:Withsmallerunits(ofupto3kg)areinforcementpanelofsufficientstrengthcanbeinstalledbehindtheelement.Thereinforcementpanelmustextendallthewayintothemainrunners,sothattheweightistransferredtothem.Thetotalweightshouldnotbegreaterthan3kgforeachm²ofceiling.Whereloadsaregreaterthan3kg/m²,additionalhangersmustbeusedUnitsover3kg,shouldbeinstalledindependently,sothattheydonotplaceanyloadontheceiling.
ProductCategory
Self-supportingCeilings
Products Unity6Bridge,Corridor400,CorridorSwing CorridorF30
Surface Whitepainted Foilfinish
Upkeep Designedforuseundernormalconditions,i.e.upto70%RHand25°C,e.g.inoffices,institutionsandsimilarpremises.Unity6Bridge,Corridor400andCorridorF30havealsobeentestedat90%RHat30ºCandcanbeusedundermoreextremeconditionssuchaskitchens,laboratoriesandroomswithfrequentandmajorchangesinthetemperatureandairhumidity.
Cleaning Dustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampclothusingnormalcleaningpracticesandneutralcleaningsolutions.Stubbornmarksandminordamagesshouldbewipedcleanpriortorepainting.
Dustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampclothusingamilddetergentifnecessary.
Onnon-perforatedtilesstrongercleaningagentsmaybeusedwherenecessarytoremovestub-bornmarksorwherecleaningregimesrequireit.
Repair Morevisibledamagesandscratchesonthesurfacecanberepairedusingfillerandfinishingwithsandpaperpriortorepainting.WhenpaintinguseKnaufDanolinerepairpaintorsimilar(asNCS0700orclosestRAlcolour9003)andapplybypaintroller.Spraypaintingisnotrecommendedonperfora-tedproducts,asthereisagreatriskofthespraypaintbeingappliedtotheacousticfeltbackingtherebyalteringtheacousticproperties.
Damagesandscratchesaredifficulttorepairandthereforeitisrecommendedtoreplacedamagedtileswithnew.
lampsuspension
UNITY6BRIDGE,CORRIDOR400:Unitsweighingupto3kgcanbeinstalleddirectlyintothepanelwithoutreinforcement.N.B.Themaximumcut-out,wheninstallinginthecentreofthepanelisØ265mm/265x265mm.Unitsover3kg,shouldbesupportedindepen-dently,sothattheydonotplaceanyloadontheceiling.
CORRIDORSWING:Theceilingtilemaynotbearadditionalweightfromotherinstalla-tions.
Objectsuptoamaximumof17kgcanbesus-pendedusingappropriatefixings.
BestPractice:Useofcleancottongloveswhenhandlingpaintedandfoil-coveredproductelementswillensureagoodresultandaceilingwithoutfingermarks.
UPKEEP&MAINTENANCE
243-242
ProductCategory
Non-demountableCeilingsandWalllinings
Products Danopanel Designpanel,Tectopanel,Solopanel,Stratopanel
Contrapanel,Adit Kinopanel,Amfipanel
Surface Whitepainted Untreated Foilfinish Blackpainted
Upkeep Designedforuseundernormalconditions,i.e.upto70%RHand25°C,e.g.inoffices,institutionsandsimilarpremises.
DESIGNPANEl,TECTOPANEl:Thepanelshavealsobeentestedat90%RHat30ºCandcanbeusedundermoreextremeconditionssuchaskitchens,laboratoriesandroomswithfrequentandmajorchangesinthetemperatureandairhumidity.Inareasofhighhumidityconsiderationshouldbegiventoanticorrosionsuspensionsystemsanddurable/washablesurfacefinishes.
CONTRAPANEl:Designedforuseinsportshallsandsimilarareaswhereconditionsdonotnormallyexceed70%RHand25°C.ADIT:Thepanelsarecustommadeanddesignedforuseundernormalconditions,i.e.70%and25°C,e.g.inoffices,institutionsandsimilarpremisesunlessother-wiseadvised.
AditandContrapanelhavealsobeentestedat90%RHat30ºCandcanbeusedundermoreextremeconditionswithfrequentandmajorchangesintempera-tureandairhumidity.
Designedforuseincinemas,theatres,studiosandsimilarpre-misesundernormalconditions,i.e.upto70%RHand25°C.
Cleaning Dustisremovedusingadrydusterorvacuumcleaner.Removalofmarksdependsonthepaintusedonsite,althoughadampclothusingnormalcleaningpracticesandneutralcleaningsolutionsisnormallysuitableforminormarks.Inthecaseofstubbornmarksorifindoubtrefertothepaintmanufacturer’srecommendations.CONTRAPANEl:Dustisremovedusingadrydusterorvacuumcleaner.Markscanberemovedwithadampclothusingnormalcleaningprac-ticesandneutralcleaningsolutions.Onnon-perforatedtilesstrongercleaningagentsmaybeusedwherenecessarytoremovestubbornmarksorwherecleaningregimesrequireit.
Repair Morevisibledamagesandscratchesonthesurfacecanberepairedusingfillerandfinishingwithsandpaperpriortorepain-ting.WhenpaintinguseKnaufDanolinerepairpaintorsimilar(closestRAlcolour9003)andap-plybypaintroller.Spraypaintingisnotrecommendedonperfora-tedproducts,asthereisariskofthespraypaintbeingappliedtotheacousticfeltbackingtherebyalteringtheacousticproperties.
Useapaintrollertoapplypaint.Usethesamepaintastheoriginalsurfacefinishchosen.Spraypaintingisnotrecommendedonperforatedproducts,asthereisagreatriskofthespraypaintbeingappliedtotheacousticfeltbackingtherebyalteringtheacousticproperties.
Damagesandscratchesaredifficulttorepairandthereforeitisrecommendedtoreplacedamagedpanelswithnew.
WhenpaintinguseKnaufDanolinerepairpaintorsimilar(asNCSS9000-N)andapplybypaintroller.Spraypaintingisnotrecommendedonperforatedproducts,asthereisariskofthespraypaintbeingappliedtotheacousticfeltbackingtherebyalteringtheacousticproperties.
lampsuspension
Thetilemaynotbearadditionalweightfromotherinstallations.lightobjectsuptoamaximumof3kg/m²maybeinstalledwheretheycanbesuspendedfromthefurringsystemwhichmustbeabletobearthefullweight.
lightobjectsuptoamaximumof3kgcanbesuspendedusingappropriatefixings.Itemsover3kgmustbesuspendedfromthefurringsystemwhichmustbeabletobearthefullweight.
CONTRAPANEl:lightobjectsuptoamaximumof3kgcanbesuspendedusingappropriatefixings.Itemsover3kgmustbesuspendedfromthefurringsystemwhichmustbeabletobearthefullweight.ADIT:Thepanelmaynotbearadditionalweightfromotherinstallations.
Thepanelmaynotbearadditi-onalweightfromotherinstalla-tions.
ProductCategory
DesignElements
Products Curvex Mitex
Surface Untreated Untreated
Upkeep Designedforcreatingorganicwallandceilingshapese.g.inoffices,institutionsandsimilarpremisesundernormalconditions,i.e.upto70%RHand25°C.
Designedforcreatingclean-cutedgeswallandceilingshapese.g.inoffices,institutionsandsimilarpremisesundernormalconditions,i.e.upto70%RHand25°C.
Cleaning Dependentonthechosensurfacefinish.
Repair Dependentonthechosensurfacefinish.
lampsuspen-sion
Thepanelsarecustommadeandmaynotbearadditionalweightfromotherinstallationsunlessotherwiseadvised.
BestPractice:Useofcleancottongloveswhenhandlingpaintedandfoil-coveredproductelementswillensureagoodresultandaceilingwithoutfingermarks.Handlingtheuntreatedpanelswithcarewillavoiddamageandsurfacecontaminationpriortopaintingandtherebyensureagoodendresult.
UPKEEP&MAINTENANCEupKeep & maIntenance
244
245-244
246
knauf danoline universeknaufdanoline.com
KNAUF DANOLINEKløvermarksvej 6 DK - 9500 Hobro
Phone: +45 96 57 3000
KNAUF DANOLINE UKC/O CPD Distribution plcHillsborough Works Langsett RoadSheffield, S6 2LW
Phone: +44 8708 638 671
KNAUF DANOLINEC/O Danogips Middle East P.O. Box 53255 Jebel Ali Free Zone Dubai United Arab Emirates
Phone: +971 4 8812281