Microlab, A Wireless Telecom Group Company, 25 Eastmans Road, Parsippany, NJ 07054 Tel: (973) 386-9696 • [email protected] • www.microlab.fxr.com • Fax: (973) 386-9191 DAS Carrier Conditioner, KM-55N Dual SISO/MIMO BTS Input to SISO/MIMO DAS PCS Band 1930-1990/1850-1910 MHz Rev. 1 *Connect for SISO Operation  Interface 1900 band MIMO BTS Tx/Rx or 2 SISO BTS Tx/Rx ports with Simplex DAS  Independently adjustable Tx and Rx levels  High Reliability, RoHS compliant  Low PIM, High Isolation  Standard 2RU EIA Rack (3.5”) This DAS Carrier Conditioner, KM-55N, is designed to inte r- face either a single MIMO or 2 SISO Tx/Rx signals in the 1900 MHz PCS frequency range, with a simplex MIMO or simplex SISO DAS system. It allows independent level adjustment of the Tx and Rx elements of the wireless signal, once the signal is already split into Tx and Rx paths. The unit first separates each of the Tx/Rx inputs into Tx and Rx paths using a duplexer in both Leg A and Leg B. Each of the Tx outputs are then attenuated by a fixed 15dB attenuator before being fed to a 0-30 dB level adjustment to set optimum DAS performance. Each DAS Rx signal is fed to the Rx port of the duplexers via a similar level adjustment. If the system uses 2 SISO signals they may be combined with a supplied external jumper to feed a common DAS in both the Tx and Rx paths. Similar systems can be supplied for other wireless bands, using appropriate duplexers. (01/13) 1900 BTS Inputs Tx/Rx 0 Leg A Tx/Rx 1 Leg B Frequency: 1930-1990 Tx/1850-1910 Rx Return Loss: >15 dB, all ports Tx Power/input: 40W avg max., 3 kW max pk. Tx Path, SISO: >18 dB 1  attenuation plus an (with 15 dB pad)  adjustable 30 dB in 1 dB steps. Rx Path, SISO: 3 dB 2  min. attenuation plus an  adjustable 30 dB in 1 dB steps. PIM, typical: <-153 dBc in Rx band at input  using two +43dBm tones Isolation P0 to P1:  MIMO mode: Isolated/Isolated  SISO mode: >60/25 dB (0dB on all attenuators) Impedance: 50Ω nominal Environment: 0°C to +65°C, IP64 Housing: 2RU, Passivated aluminum Connectors: N(f), Triplate Weight: 40 lbs. nom. Notes:  In MIMO Mode:  1 >15dB Leg B 2 1.4dB typ. Leg B Specifications subject to change Leg A Tx or Leg AB Tx (Leg B Tx)* Leg B Tx* Leg B Tx or Leg AB Rx (Leg B Rx)* Leg B Rx* 1 Power Combiner 2 1 Power Combiner 2 15 dB  Attenuator 0 - 30 dB  Attenuator 0 - 30 dB  Attenuator  Tx Duplexer Network P0 Rx  Tx Duplexer Network P1 Rx 15 dB  Attenuator 0 - 30 dB  Attenuator 0 - 30 dB  Attenuator DAS Ports DCC Series™ - Preliminary Specification

Transcript of KM55N 0113 R1

Page 1: KM55N 0113 R1

7/27/2019 KM55N 0113 R1

http://slidepdf.com/reader/full/km55n-0113-r1 1/1

Microlab, A Wireless Telecom Group Company, 25 Eastmans Road, Parsippany, NJ 07054

Tel: (973) 386-9696 • [email protected] • www.microlab.fxr.com • Fax: (973) 386-9191

DAS Carrier Conditioner, KM-55N

Dual SISO/MIMO BTS Input to SISO/MIMO DAS

PCS Band 1930-1990/1850-1910 MHzRev. 1

*Connect

for SISO

Operation

  Interface 1900 band MIMO BTS Tx/Rx or 2 SISO BTS Tx/Rx ports with Simplex DAS  Independently adjustable Tx and Rx levels   High Reliability, RoHS compliant  Low PIM, High Isolation   Standard 2RU EIA Rack (3.5”)

This DAS Carrier Conditioner, KM-55N, is designed to inter-

face either a single MIMO or 2 SISO Tx/Rx signals in the 1900

MHz PCS frequency range, with a simplex MIMO or simplex SISO

DAS system.

It allows independent level adjustment of the Tx and Rx

elements of the wireless signal, once the signal is already split

into Tx and Rx paths.

The unit first separates each of the Tx/Rx inputs into Tx

and Rx paths using a duplexer in both Leg A and Leg B. Each ofthe Tx outputs are then attenuated by a fixed 15dB attenuator

before being fed to a 0-30 dB level adjustment to set optimum

DAS performance. Each DAS Rx signal is fed to the Rx port of

the duplexers via a similar level adjustment.

If the system uses 2 SISO signals they may be combined

with a supplied external jumper to feed a common DAS in both

the Tx and Rx paths.

Similar systems can be supplied for other wireless bands,

using appropriate duplexers. (01/13)

1900 BTSInputs

Tx/Rx 0

Leg A

Tx/Rx 1

Leg B

Frequency: 1930-1990 Tx/1850-1910 Rx

Return Loss: >15 dB, all ports

Tx Power/input: 40W avg max., 3 kW max pk.Tx Path, SISO: >18 dB1 attenuation plus an(with 15 dB pad)  adjustable 30 dB in 1 dB steps.Rx Path, SISO: 3 dB2 min. attenuation plus an

  adjustable 30 dB in 1 dB steps.

PIM, typical: <-153 dBc in Rx band at input

  using two +43dBm tones

Isolation P0 to P1:  MIMO mode: Isolated/Isolated

  SISO mode: >60/25 dB (0dB on all attenuators)Impedance: 50Ω nominal

Environment: 0°C to +65°C, IP64

Housing: 2RU, Passivated aluminumConnectors: N(f), Triplate

Weight: 40 lbs. nom.

Notes:

  In MIMO Mode:  1 >15dB Leg B 21.4dB typ. Leg B

Specifications subject to change

Leg A Tx or Leg AB Tx

(Leg B Tx)*

Leg B Tx*

Leg B Tx or Leg AB Rx

(Leg B Rx)*

Leg B Rx*

1Power 

Combiner 2

1Power 

Combiner 2

15 dB

 Attenuator 

0 - 30 dB

 Attenuator 

0 - 30 dB

 Attenuator 

  Tx

Duplexer 

Network

P0 Rx

  Tx

Duplexer 

Network

P1 Rx

15 dB

 Attenuator 

0 - 30 dB

 Attenuator 

0 - 30 dB

 Attenuator 

DAS Ports