KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton,...

11
RICE FERGUS MILLER 275 5TH ST, SUITE 100 BREMERTON, WA 98337 ARCHITECT GREGORY BELDING, ARCHITECT OF RECORD (360) 362 - 1429 [email protected] KING COUNTY HOUSING AUTHORITY 700 ANDOVER PARK WEST, SUITE C SEATTLE, WA 98188 OWNER CARL FRANKEL, PROJECT MANAGER (206) 574 - 1219 [email protected] LORIE LIMSON COOK, PROJECT MANAGER (360) 850 - 4567 [email protected] BCE ENGINEERS, INC. 6021 12TH STREET EAST, SUITE 200 FIFE, WA 98424 MECHANICAL/ELECTRICAL/PLUMBING SCOTT ZIMBELMAN, PROJECT MANAGER (253) 922 - 0446 [email protected] FRANCIS MASOTTO, MECHANICAL/PLUMBING (253) 922 - 0446 [email protected] TBD CONTRACTOR N PROJECT SITE SE 192ND STREET 116TH AVE SE 108TH AVE SE P AN THER LAKE PARCEL NUMBER PROJECT TYPE CONSTRUCTION TYPE PROJECT SCOPE 322305 - 9036 PLUMBING SYSTEMS RENOVATION TYPE VB REPLACEMENT OF ALL EXISTING DOMESTIC PIPING AND WASTE PIPING, AND ASSOCIATED ARCHITECTURAL PATCHING AND REPAIR FOR ALL (28) SINGLE - FAMILY HOMES. 116TH AVENUE SE S E 189T H L A N E SE 189TH LANE EC EXISTING PLAYGROUND S E 189T H L A N E EXISTING LAWN & LANDSCAPING PROPERTY LINE = 131.26 ' P R O P E R T Y L I N E = 1 6 5 . 0 4 ' PROPERTY LINE = 568.96' PROPERTY LINE = 360.00' P R O P E R TY L I N E = 4 6 2 . 6 7 ' PROPERTY LINE = 371.67' P R O P E R T Y L I N E = 2 9 9 . 8 6 ' PROPERTY LINE = 440.00' EXISTING LANDSCAPING EXISTING CHAINLINK FENCING, TYP EC EC EC EC EC EC EC EC EC E BC BC BC BC B B B E D-2 D-3 D-3 D-2 D-3 D-2 D-3 EC EC 1 A26.02 1 A26.01 SIM 1 A26.01 1 A26.03 SIM 1 A26.03 EXISTING BUS STOP EXISTING BUS STOP SIM 1 A26.02 LANDSCAPED AREA (PERVIOUS) PAVED AREA (IMPERVIOUS) BUILDING FOOTPRINT (IMPERVIOUS) CHAINLINK FENCING 275 FIFTH STREET, SUITE 100 BREMERTON, WA 98337 360-377-8773 RFMARCH.COM PROJECT # ISSUE DATE SHEET # 2017036.16 PERMIT/BID SET 01/24/2020 A00.01 COVER SHEET YOUNGS LAKE 115TH LANE SE RENTON, WASHINGTON 98055 KING COUNTY HOUSING AUTHORITY PERMIT/BID SET KING COUNTY HOUSING AUTHORITY YOUNGS LAKE PROJECT TEAM VICINITY MAP PROJECT INFORMATION DRAWING INDEX SHEET # SHEET NAME REVISION ARCHITECTURAL A00.01 COVER SHEET A00.02 GENERAL INFORMATION A02.01 ASSEMBLY TYPES & DETAILS A26.01 TYPICAL UNIT PLANS - TYPE B & B-C A26.02 TYPICAL UNIT PLANS - TYPE D A26.03 TYPICAL UNIT PLANS - TYPE E & E-C PLUMBING P0.01 GENERAL PLUMBING NOTES P1.01 SITE PLAN P2.01 UNIT TYPE B P2.02 UNIT TYPE D P2.03 UNIT TYPE E NUMBER OF SHEETS: 11 N 1" = 60' - 0" 1 SITE PLAN LEGEND - SITE PLAN SINGLE-FAMILY HOMES SCHEDULE UNIT TYPE DESCRIPTION QUANTITY B 3 BED / 2 BATH 3 B-C 3 BED / 2 BATH / CARPORT 4 D-2 2 BED / 1 BATH 3 D-3 3 BED / 1 BATH 4 E 3 BED / 1 BATH 2 E-C 3 BED / 1 BATH / CARPORT 12 TOTAL SINGLE FAMILY HOMES: 28 REVISION SCHEDULE

Transcript of KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton,...

Page 1: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

RICE FERGUS MILLER275 5TH ST, SUITE 100BREMERTON, WA 98337

ARCHITECT

GREGORY BELDING, ARCHITECT OFRECORD(360) [email protected]

KING COUNTY HOUSING AUTHORITY700 ANDOVER PARK WEST, SUITE CSEATTLE, WA 98188

OWNER

CARL FRANKEL, PROJECT MANAGER(206) [email protected]

LORIE LIMSON COOK, PROJECT MANAGER(360) [email protected]

BCE ENGINEERS, INC.6021 12TH STREET EAST, SUITE 200FIFE, WA 98424

MECHANICAL/ELECTRICAL/PLUMBING

SCOTT ZIMBELMAN, PROJECT MANAGER(253) [email protected]

FRANCIS MASOTTO,MECHANICAL/PLUMBING(253) [email protected]

TBD

CONTRACTOR

N

PROJECT SITE

SE 192ND STREET

116T

H A

VE

SE

108T

H A

VE

SE

PAN

THER

LAKE

PARCEL NUMBER

PROJECT TYPE

CONSTRUCTION TYPE

PROJECT SCOPE

322305-9036

PLUMBING SYSTEMS RENOVATION

TYPE VB

REPLACEMENT OF ALL EXISTINGDOMESTIC PIPING AND WASTE PIPING,AND ASSOCIATED ARCHITECTURALPATCHING AND REPAIR FOR ALL (28)SINGLE-FAMILY HOMES.

116TH AVENUE SE

SE

18

9T

H L

AN

E

SE 189TH LANE

EC

EXISTING PLAYGROUND

SE

18

9T

H L

AN

E

EXISTING LAWN & LANDSCAPING

PROPERTY LINE = 131.26'

PR

OP

ER

TY

LIN

E =

165.0

4'

PROPERTY LINE = 568.96'PROPERTY LINE = 360.00'

PR

OP

ER

TY

LI N

E =

462.6

7'

PROPERTY LINE = 371.67'

PR

OP

ER

TY

LIN

E =

299.8

6'

PROPERTY LINE = 440.00'

EXISTING LANDSCAPING

EXISTING CHAINLINK FENCING, TYP

EC

EC

EC

EC EC EC

ECEC EC

E

BC

BC BC BC B B

B

E

D-2

D-3

D-3

D-2

D-3

D-2

D-3

EC

EC1

A26.02

1A26.01

SIM1

A26.01

1A26.03

SIM1

A26.03

EXISTING BUS STOP

EXISTING BUS STOP

SIM1

A26.02

LANDSCAPED AREA (PERVIOUS)

PAVED AREA (IMPERVIOUS)

BUILDING FOOTPRINT (IMPERVIOUS)

CHAINLINK FENCING

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET

01/24/2020

A00.01

COVER SHEET

YO

UN

GS

LA

KE

115T

H L

AN

E S

ER

EN

TO

N, W

AS

HIN

GT

ON

980

55

KIN

G C

OU

NT

Y H

OU

SIN

G A

UT

HO

RIT

Y

PERMIT/BID SET

KING COUNTY HOUSING AUTHORITYYOUNGS LAKE

PROJECT TEAM

VICINITY MAP

PROJECT INFORMATION

DRAWING INDEXSHEET # SHEET NAME REVISION

ARCHITECTURAL

A00.01 COVER SHEET

A00.02 GENERAL INFORMATION

A02.01 ASSEMBLY TYPES & DETAILS

A26.01 TYPICAL UNIT PLANS - TYPE B & B-C

A26.02 TYPICAL UNIT PLANS - TYPE D

A26.03 TYPICAL UNIT PLANS - TYPE E & E-C

PLUMBING

P0.01 GENERAL PLUMBING NOTES

P1.01 SITE PLAN

P2.01 UNIT TYPE B

P2.02 UNIT TYPE D

P2.03 UNIT TYPE E

NUMBER OF SHEETS: 11

N

1" = 60'-0"1

SITE PLAN

LEGEND - SITE PLAN

SINGLE-FAMILY HOMES SCHEDULEUNIT TYPE DESCRIPTION QUANTITY

B 3 BED / 2 BATH 3

B-C 3 BED / 2 BATH / CARPORT 4

D-2 2 BED / 1 BATH 3

D-3 3 BED / 1 BATH 4

E 3 BED / 1 BATH 2

E-C 3 BED / 1 BATH / CARPORT 12

TOTAL SINGLE FAMILY HOMES: 28

REVISION SCHEDULE

Page 2: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

CONSTRUCTION

LINE STYLES

EXISTING ELEMENT TO REMAIN

DEMOLISHED ELEMENT

NEW CONSTRUCTION ELEMENT

BATT INSULATION

CENTERLINE

CLEARANCES

HIDDEN ELEMENT

OPENING BEYOND

OVERHEAD ELEMENT

PROPERTY LINE

HATCH PATTERNS

OUT OF SCOPE

EARTH BELOW GRADE

GYPSUM BOARD

CONCRETE

METAL

RIGID INSULATION

WOOD

MASONRY, BRICK (PLAN VIEW)

MASONRY, CMU (PLAN VIEW)

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET

01/24/2020

A00.02

GENERAL

INFORMATION

YO

UN

GS

LA

KE

115T

H L

AN

E S

ER

EN

TO

N, W

AS

HIN

GT

ON

980

55

KIN

G C

OU

NT

Y H

OU

SIN

G A

UT

HO

RIT

Y

-- A --

A AMPA/V AUDIO VISUALAB ANCHOR BOLTACC ACCESSORIESACST ACOUSTIC(AL)ACT ACOUSTIC CEILING TILEADJ ADJACENT,

ADJUST(ABLE)AFF ABOVE FLOOR FINISHALT ALTERNATEALUM ALUMINUMAPPROX APPROXIMATELYARCH ARCHITECT(URAL)AUTO AUTOMATIC

-- B --

BATH BATHROOMBD BOARDBED BEDROOMBLDG BUILDINGBLKG BLOCKINGBM BEAMBO BOTTOM OFBTWN BETWEENBUR BUILT UP ROOF(ING)

-- C --

CAB CABINETCALC CALCULATIONCB CATCH BASIN,

CORNER BEADCEM CEMENTCFOI CONTRACTOR FURNISHED & OWNER INSTALLEDCG CORNER GUARDCH COAT HOOKCIP CAST IN PLACECJ CONTROL JOINT,

CONSTRUCTION JOINTCL CENTERLINECLG CEILINGCLO CLOSETCLR CLEARCMU CONCRETE MASONRY UNITCO CLEAN OUTCOL COLUMNCONC CONCRETECONF CONFERENCECONN CONNECT(ION)CONSTR CONSTRUCTIONCONT CONTINUE,

CONTINUOUSCONTR CONTRACTORCOORD COORDINATECORR CORRIDORCP CEMENT PLASTERCPT CARPETCRL CHAIR RAILCS CONCRETE SEALERCSMT CASEMENTCTR CENTER

-- D --

D DEEP,DRYER

DBL DOUBLEDEB DRY ERASE BOARDDEMO DEMOLISH(ED),

DEMOLITIONDEPT DEPARTMENTDET DETAILDF DRINKING FOUNTAINDIA DIAMETERDIM DIMENSIONDISP DISPOSALDL DEAD LOADDN DOWNDP DECORATIVE PANELDR DOOR,

DINING ROOM,DRAIN

DS DOWNSPOUTDW DISHWASHERDWG DRAWINGDWR DRAWER

-- E --

E EASTEA EACHEC EDGE OF CURBEE EACH ENDEIFS EXTERIOR INSULATION & FINISH SYSTEMEF EACH FACEEJ EXPANSION JOINTEL ELEVATIONELEC ELECTRICALELEV ELEVATOREMER EMERGENCYENCL ENCLOSE(D),

ENCLOSUREEP ELECTRICAL PANELBOARDEQ EQUALEQUIP EQUIPMENTEST ESTIMATE(D)EW EACH WAYEWC ELECTRIC WATER COOLEREWH ELECTRIC WATER HEATEREXH EXHAUSTEXIST EXISTINGEXP EXPOSED,

EXPANSIONEXT EXTERIOR

-- F --

FA FIRE ALARMFAAP FIRE ALARM ANNUNCIATOR PANELFD FLOOR DRAINFDC FIRE DEPARTMENT CONNECTIONFDTN FOUNDATIONFDV FIRE DEPARTMENT VALVEFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINET FF FACTORY FINISH,

FINISH FACEFH FIRE HYDRANTFHC FIRE HOSE CABINETFHR FIRE HOSE RACK,

FIRE HOSE REELFILM SPECIALTY FILMFIN FINISH(ED)FIXT FIXTUREFLASH FLASHINGFLR FLOORFLUOR FLUORESCENTFMF FLEXIBLE MEMBRANE FLASHING

-- F CONTINUED --

FOB FACE OF BRICKFOC FACE OF CONCRETEFOF FACE OF FINISHFOM FACE OF MASONRYFOS FACE OF STUDFPL FIREPLACEFRP FIBER REINFORCED PLASTICFRTW FIRE RETARDANT TREATED WOODFRZ FREEZERFS FULL SIZEFT FOOT,

FEETFTG FOOTINGFURN FURNITURE

-- G --

G GROUNDGA GAUGEGALV GALVANIZEDGAR GARAGEGB GRAB BARGC GENERAL CONTRACTORGEN GENERALGFRG GLASS REINFORCED PLASTER,

GLASS FIBER REINFORCED GYPSUMGI GALVANIZED IRONGL GLASS,

GLAZINGGLULAM GLUE LAMINATEDGR GROSSGT GROUTGWB GYPSUM WALL BOARD

-- H --

H HIGH,HEIGHT

HB HOSE BIBHC HOLLOW COREHDR HEADERHDW HARDWAREHGR HANGERHM HOLLOW METALHRL HANDRAILHORIZ HORIZONTALHR HOURSHT HEIGHTHVAC HEATING, VENTILATION & AIR CONDITIONINGHWT HOT WATER TANK

-- I --

IIC IMPACT INSULATION CLASSIN INCH(ES)INC INCREASEINCL INCLUDE(D),

INCLUDINGINFO INFORMATIONINSTL INSTALL(ATION)INSUL INSULATIONINT INTERIOR

-- J --

JAN JANITORJBOX JUNCTION BOXJT JOINT

-- K --

KD KILN DRIEDKIT KITCHENKW KILOWATT

-- L --

L LEFT,LINEN,LONG

LAB LABORATORYLAM LAMINATE(D)LAU LAUNDRYLAV LAVATORYLB(S) POUND(S)LDG LANDINGLINO LINOLEUMLL LIVE LOADLOC LOCATIONLPT LOW POINTLR LIVING ROOMLRG LARGELT LIGHTLTG LIGHTINGLVR LOUVER

-- M --

M/S MIRROR & SHELFMACH MACHINEMAINT MAINTENANCEMATL MATERIALMAX MAXIMUMMB MACHINE BOLTMBR MASTER BEDROOMMC MEDICINE CABINETMDO MEDIUM DENSITY OVERLAYMECH MECHANIC(AL)MED MEDIUMMEDS MEDICINE,

MEDICALMEMB MEMBRANEMEZZ MEZZANINEMFR MANUFACTURERMFRREC MANUFACTURER'S RECOMMENDATION(S)MGR MANAGERMH MANHOLEMIN MINIMUMMIR MIRRORMISC MISCELLANEOUSMO MASONRY OPENING,

MONITORMTD MOUNTEDMTL METALMULL MULLIONMULT MULTIPLEMW MICROWAVE OVEN

-- N --

N NORTHNA NOT APPLICABLENC NOISE CRITERIA,

NURSE CALLNCAP NURSE CALL ANNUNCIATOR PANELNIC NOT IN CONTRACTNO NUMBERNOM NOMINALNTS NOT TO SCALE

-- O --

O/ OVEROA OVERALLOC ON CENTEROCC OCCUPANTS,

OCCUPANT LOAD,OCCUPANCY

OD OUTSIDE DIAMETEROFCI OWNER FURNISHED & CONTRACTOR INSTALLEDOFOI OWNER FURNISHED & OWNER INSTALLEDOFD OVERFLOW DRAINOFF OFFICEOGL OBSCURE GLASSOH OVERHEADOPH OPPOSITE HANDOPNG OPENINGOPP OPPOSITEORD OVERFLOW ROOF DRAINOZ OUNCE

-- P --

P PAINT(ED),PANTRY

PC PORTLAND CEMENTPCC PRECAST CONCRETEPED PEDESTALPERF PERFORATEDPERM PERMANENTPERP PERPENDICULARPFP PREPARED FOR PAINTPIV POST INDICATOR VALVEPL PLATE,

PROPERTY LINEPLAM PLASTIC LAMINATEPLAS PLASTERPLBG PLUMBINGPLYWD PLYWOODPMTL PAINTED METALPNT POINTPP POWER POLEPR PAIRPREFAB PREFABRICATEPRELIM PRELIMINARYPRKG PARKINGPROP PROPERTYPS PROJECTOR SCREENPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPT PRESERVATIVE TREATED,

PRESSURE TREATED,POST TENSIONED

PTD PAPER TOWEL DISPENSERPTN PARTITIONPVC POLYVINYL CHLORIDE,

POLYVINYL CHLORIDE PIPE PVD PROVIDEPVG PAVINGPVR PAVERS

-- Q --

QTY QUANTITYQTZ QUARTZ

-- R --

R RISER,RADIUS

R/S ROD & SHELFRA RETURN AIRRCP REFLECTED CEILING PLANRD ROOF DRAINREBAR REINFORCING BARREC RECESSEDRECPT RECEPTACLEREF REFERENCE,

REFRIGERATORREINF REINFORCE(D),

REINFORCINGRES RESILIENT REQD REQUIREDREST RESTROOMRET RETAININGREV REVISED,

REVISIONRF RAISED FLOOR(ING)RH ROBE HOOKRM ROOMRO ROUGH OPENINGRP RADIUS POINTRS ROUGH SAWNRT RIGHTRVL REVEAL

-- S --

S SOUTH,SINK

SAN SANITARYSC SOLID CORESCD SEAT COVER DISPENSERSCHED SCHEDULESD SOAP DISH,

SOAP DISPENSER,STORM DRAIN

SEAL SEALER,SEALANT

SECT SECTIONSEP SEPARATIONSF SQUARE FEETSG SAFETY GLASS,

SAFETY GLAZINGSHR SHOWERSHT SHEETSHTG SHEATHING,

SHEETINGSHLV SHELVINGSIM SIMILARSM SHEET METALSND SANITARY NAPKIN DISPOSALSOG SLAB ON GRADESOL SOLID SURFACESTO STONESPEC SPECIFICATION(S)SPKLR SPRINKLERSPKR SPEAKERSQ SQUARESQIN SQUARE INCHSS SERVICE SINK,

SANITARY SEWERSST STAINLESS STEELST STREET,

STAINSTA STATIONSTC SOUND TRANSMISSION CLASSSTD STANDARDSTL STEELSTOR STORAGESTRUCT STRUCTURALSU SOILED UTILITYSUBFL SUBFLOORSUSP SUSPENDEDSW SWITCHSYM SYMMETRICAL

-- T --

T TREAD, TILE

T&B TOP AND BOTTOMT&G TONGUE AND GROOVETB TOWEL BARTEL TELEPHONETEMP TEMPORARY,

TEMPERATURETER TERRAZZOTHK THICK(NESS)TI TENANT IMPROVEMENTTL TOTAL LOADTMPD TEMPEREDTO TOP OFTOB TOP OF BEAMTOC TOP OF CURB,

TOP OF CONCRETETOF TOP OF FOOTING,

TOP OF FLOOR,TOP OF FRAME

TOS TOP OF SLAB,TOP OF STEEL

TOW TOP OF WALLTPD TOILET PAPER DISPENSERTR TRANSITION STRIPTV TELEVISIONTYP TYPICAL

-- U --

UC UNDERCOUNTER,UNDERCABINET,UNDERCUT

UGND UNDERGROUNDUNO UNLESS NOTED OTHERWISEUP UTILITY POLEUTIL UTILITY

-- V --

V VOLT(AGE)VCT VINYL COMPOSITION TILEVEH VEHICLEVEND VENDING MACHINEVERT VERTICALVEST VESTIBULEVIF VERIFY IN FIELDVNR VENEERVTO VENT TO OUTSIDEVTR VENT THROUGH ROOF

-- W --

W WEST,WIDE,WASHING MACHINE

W/ WITHW/D WASHER & DRYERW/O WITHOUTWB WALL BASEWC WATER CLOSET,

WALL COVERINGWCO WINDOW COVERINGWD WOODWF WIDE FLANGEWH WATER HEATERWIC WALK-IN CLOSETWIN WINDOWWM WIRE MOLD,

WATER METER,WIRE MESH

WO WALK-OFF FLOORINGWP WORK POINT,

WATERPROOFING,WEATHERPROOF

WPM WATERPROOF MEMBRANEWR WATER REPELLENT,

WATER RESISTANTWRB WATER RESISTANT BARRIERWSCT WAINSCOTWRC WASTE RECEPTACLEWT WEIGHTWWF WELDED WIRE FABRIC

-- ASSOCIATIONS & CODES --

AISI AMERICAN IRON AND STEEL INSTITUTEAMCA AIR MOVING & CONDITIONING ASSOCIATIONANSI AMERICAN NATIONAL STANDARDS INSTITUTEAPA AMERICAN PLYWOOD ASSOCIATIONAPWA AMERICAN PUBLIC WORKS ASSOCIATIONARIB ASPHALT ROOFING INDUSTRY BUREAUASME AMERICAN SOCIETY OF MECHANICAL ENGINEERSASTM AMERICAN SOCIETY FOR TESTING & MATERIALSAWI AMERICAN WOODWORK INSTITUTEAWS AMERICAN WELDING SOCIETYAWWA AMERICAN WATER WORKS ASSOCIATIONCRSI CONCRETE REINFORCING STEEL INSTITUTECS COMMERCIAL STANDARD OF THE US DEPARTMENT OF COMMERCECSI CONSTRUCTION SPECIFICATIONS INSTITUTEFGI FACILITY GUIDELINES INSTITUTEFGMA FLAT GLASS MARKETING ASSOCIATIONGA GYPSUM ASSOCIATIONHUD US DEPARTMENT OF HEALTH & URBAN DEVELOPMENTIBC INTERNATIONAL BUILDING CODEICC INTERNATIONAL CODE COUNCILIEEE INSTITUTE OF ELECTRICAL & ELECTRONIC ENGINEERSIFC INTERNATIONAL FIRE CODEIMC INTERNATIONAL MECHANICAL CODEIRC INTERNATIONAL RESIDENTIAL CODEIPCEA INSULATED POWER CABLE ENGINEER ASSOCIATIONMLA METAL LATH ASSOCIATIONNAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERSNEMA NATIONAL FIRE PROTECTION ASSOCIATIONNWMA NATIONAL WOODWORK MANUFACTURER'S ASSOCIATIONOSHA OCCUPATIONAL SAFETY & HEALTH ADMINISTRATIONPS PRODUCT STANDARD OF US DEPARTMENT OF COMMERCESDI STEEL DECK INSTITUTE,

STEEL DOOR INSTITUTESMACNA SHEET METAL & AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATIONSSPC STEEL STRUCTURES PAINTING COUNCILTCA TILE COUNCIL OF AMERICAUL UNDERWRITER'S LABORATORIESUPC UNIFORM PLUMBING CODEWAC WASHINGTON ADMINISTRATIVE CODEWISHA WASHINGTON INDUSTRIAL SAFETY AND HEALTH ACTWSDOH WASHINGTON STATE DEPARTMENT OF HEALTHWSDSHS WASHINGTON STATE DEPARTMENT OF SOCIAL & HEALTH SERVICESWSEC WASHINGTON STATE ENERGY CODEWSVIAQC WASHINGTON STATE VENTILATION & INDOOR AIR QUALITY CODEWWPA WESTERN WOOD PRODUCTS ASSOCIATION

WALL TAG

WINDOW TAG

STOREFRONT TAG

CURTAIN WALL TAG

A##.###

A##.###

#A##.##

#A##.##

#A##.##

X##X

W##

S##

C##

FINISH TAGXXX-#

DOOR TAG###X

FURNITURE/ EQUIPMENT TAGXXX-#

KEYNOTE##

DRAWING LEGEND

LEVEL NAME

ELEVATION

ELEVATION

X

N

TRUE NORTH

#

SHEET LAYOUT

1. DETAIL NUMBERS MAY FOLLOW A NUMBERING SEQUENCE SIMILAR TO DIAGRAM BELOW.2. DETAIL NUMBERS MAY SKIP WHEN A DETAIL FALLS WITHIN MULTIPLE CELLS.

ABBREVIATIONS

# / A##.##

LIGHTING TAGL#

GLAZING TAGGL#

PLAN NORTH

DRAWING ORGANIZATION

--VIEW REFERENCE--

BUILDING SECTION

#A##.##

WALL SECTION,VERTICAL SHAFT / CHASE

DETAIL SECTION

EXTERIOR ELEVATION

INTERIOR ELEVATION

ENLARGED VIEW,DETAIL VIEW

--ANNOTATIONS--

NORTH ARROW

SPOT ELEVATION

GRID LINE

MATCH LINE

BREAK LINE

REVISION CLOUD W/ TAG

--TAGS--

ELEVATION DATUM

--LINEWORK--

3

4

2

1

7

8

6

5

11

12

10

9

15

16

14

13

19

20

18

17

TIT

LEB

LOC

K

SHEET LAYOUT DIAGRAM

REVISION SCHEDULE

Page 3: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

INTERIOR INTERIOR INTERIOR PLUMBING CHASE

WOOD STUD

5/8" GWB

FINISHED FLOOR

5/8" GWB

5/8" GWB

BO ROOF STRUCTURE

RATING

SOURCE

STC

BATT

TYPE W01

NA

EXISTING

-

-

RATING

SOURCE

STC

BATT

TYPE W02

NA

EXISTING

-

-

WOOD STUD

TYPICAL INTERIOR PARTITION CONDITIONS @ CEILING / BOTTOM OF ROOF STRUCTURE

EXISTING BEAM

5/8" GWB OVER EXISTING BEAM

COVER PLATE SYSTEM TRACK AND SNAP-ON COVER

DOMESTIC PIPING

MIN

IMU

M D

EP

TH

NE

ED

ED

TO

CA

PT

UR

E P

IPIN

G

MINIMUM WIDTH NEEDEDTO CAPTURE PIPING

5/8" GYPSUM BOARD CEILING

RUN PIPING AND COVER PLATE TIGHT AGAINST BOTTOM OF CEILING

BOTTOM OF CEILING

COVER PLATE SYSTEM TRACK AND SNAP-ON COVER

DOMESTIC PIPING

MIN

IMU

M D

EP

TH

NE

ED

ED

TO

CA

PT

UR

E P

IPIN

G

MINIMUM WIDTH NEEDEDTO CAPTURE PIPING

RUN PIPING AND COVER PLATE TIGHT AGAINST ADJACENT WALLS, WHERE APPLICABLE

5/8" GWB OVER EXISTING FRAMING

4" THICK CONCRETE SLAB ON GRADE

6X6 WWF

#4 REBAR; DRILL INTO EXISTING CONCRETE SLAB AT 48" OC

EXISTING CONCRETE SLAB ON GRADE

SAND

6" 2"

GRANULAR FILL

7A02.01

TOP OF KITCHEN WALL

PIPE CHASE TO CAPTURE VERTICAL RUN OF DOMESTIC PIPING; ALIGN WITH EXISTING BEAM ABOVE

EXISTING BEAM

5A02.01

RUN PIPING AND COVER PLATE ALONG VERTICAL FACE OF BEAM, TIGHT AGAINST BOTTOM OF EXISTING CEILING

CLG

5/8" GWB

DOMESTIC PIPING

ALIGN

EXISTING WALL BELOW

2X WOOD FRAMING

RUN PIPING AND COVER PLATE ALONG VERTICAL FACE OF BEAM

ALI

GN

COVER PLATE ABOVE

EXISTING BEAM ABOVE

6A02.01

EXISTING BEAM

RUN PIPING AND COVER PLATE ALONG VERTICAL FACE OF BEAM, TIGHT AGAINST BOTTOM OF EXISTING CEILING

PIPE CHASE TO CAPTURE VERTICAL RUN OF DOMESTIC PIPING

5/8" GWB OVER EXISTING FRAMING

CLG

KITCHEN LIVING

3/4" = 1'-0"1

EXISTING WALL ASSEMBLIES

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET

01/24/2020

A02.01

ASSEMBLY TYPES &

DETAILS

YO

UN

GS

LA

KE

115T

H L

AN

E S

ER

EN

TO

N, W

AS

HIN

GT

ON

980

55

KIN

G C

OU

NT

Y H

OU

SIN

G A

UT

HO

RIT

Y

3" = 1'-0"2

COVER PLATE @ BEAM3" = 1'-0"

3COVER PLATE @ BOTTOM OF CEILING

1" = 1'-0"4

INFILL SLAB ON GRADE

NOTE: FIELD VERIFY AND MAINTAIN ALL EXISTING ASSEMBLY FIRE RATINGS.

1" = 1'-0"6

PIPE CHASE VIEW - PERPENDICULAR TO BEAM3" = 1'-0"

7PIPE CHASE SECTION

1" = 1'-0"5

PIPE CHASE VIEW - PARALLEL TO BEAM

REVISION SCHEDULE

Page 4: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

1. REFERENCE PLUMBING DRAWINGS FOR INFORMATION ON PLUMBING ELEMENTS AND SYSTEMS.2. REFERENCE FOR INTERIOR WALL ASSEMBLIES. WALL ASSEMBLY TYPE W02 IS

TYPICAL, UNLESS NOTED OTHERWISE.

TYPICAL ROOM TAG

ANNOTATION TAG

CONSTRUCTION ELEMENTS

ROOM NAME

EXISTING SLAB TO BE CUT AND PATCHED

EXISTING ELEMENT TO REMAIN

DEMOLISHED ELEMENT EXISTING FLOORING TO BE REMOVED AND REPLACED

NEW POURED-IN-PLACE CONCRETE SLAB

NEW ELEMENT

COVER PLATE ON UNDERSIDE OF CEILING

1. OWNER WILL COORDINATE TENANT RELOCATION PRIOR TO BEGINNING WORK.

2. OWNER TO REMOVE AND STORE EXISTING FURNITURE, APPLIANCES, AND EQUIPMENT PRIOR TO BEGINNING WORK.

3. OWNER TO FURNISH & INSTALL:A. ALL PLUMBING FIXTURES, EXCEPT TUB

AND SHOWER VALVE.B. SUPPLY LINES AND P-TRAPSC. PLUMBING FIXTURES AND CASEWORKD. ALL WALL AND FLOOR FINISHES AND

TRIME. ALL INTERIOR DOORS, FRAMES, AND

HARDWARE

OWNER SCOPE CONTRACTOR SCOPE

1. COORDINATE WORK PLAN SEQUENCING WITH OWNER PRIOR TO BEGINNING WORK.

2. FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO BEGINNING WORK.

3. PRESERVE AND PROTECT EXISTING BUILDING SYSTEMS TO REMAIN.

4. COMPLY WITH LAWS AND REGULATIONS REGARDING HAZARDOUS MATERIALS WHERE HAZARDOUS MATERIALS ARE DISCOVERED DURING REMOVAL OPERATIONS AND AS INDICATED IN ADDITIONAL BID REPORTS. HAZARDOUS MATERIALS INCLUDE REGULATED ASBESTOS CONTAINING MATERIALS, LEAD, PCB'S, AND MERCURY.

5. CONTRACTOR TO FURNISH AND INSTALL SHOWER VALVE ROUGH-IN, TRIM, AND TUB.

NOTES

1 / A02.01

BEDROOM

BEDROOM

BEDROOM

STORAGE

LAV

BATH

DINING

KITCHEN LIVING

ENTRY

STORAGE LINEN

MECH

ROOM

FURNACE

WH

STORAGE

OUTSIDE

STOREROOM

09

07 0801 03 04 05

02

06

10

11

BEDROOM

BEDROOM

BEDROOM

STORAGE

LAV

BATH

DINING

KITCHEN LIVING

ENTRY

STORAGE LINEN

MECH

ROOM

FURNACE

WH

STORAGE

OUTSIDE

STOREROOM

04

05

05

05W01

2A02.01

CLG

3A02.01

CLG4A02.01

FLR6

A02.01

CLG

5A02.01

CLG

07

06

01 02 03

11

08

13

09

10

10

12

W01

14

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET

01/24/2020

A26.01

TYPICAL UNIT PLANS -

TYPE B & B-C

YO

UN

GS

LA

KE

115T

H L

AN

E S

ER

EN

TO

N, W

AS

HIN

GT

ON

980

55

KIN

G C

OU

NT

Y H

OU

SIN

G A

UT

HO

RIT

Y

KEY NOTES - FLOOR PLAN# NOTE DESCRIPTION

01 PROVIDE CLEANOUTS FOR ALL WASTE PIING AND UNDER ALL EXISTING SINK LOCATIONS.

02 PROVIDE ROUGH-INS FOR ALL PLUMBING FIXTURES.

03 PATCH GWB AT PLUMBING ACCESS POINTS. PROVIDE TAPE, MUD, AND TEXTURE.

04 POURED-IN-PLACE CONCRETE SLAB TO ALIGN WITH EXISTING ADJACENT FLOOR SLAB.

05 EXPOSED PIPING TO RUN TIGHT AGAINST THE BOTTOM OF THE CEILING AND ADJACENTWALLS. PROVIDE COVER PLATE OVER EXPOSED PIPING CONDUIT ON UNDERSIDE OFCEILING.

06 RUN DOMESTIC PIPING VERTICALLY WITHIN WALL.

07 PIPE CHASE.

08 ACCESS PANEL. LOCATE ACCESS PANEL ON STORAGE ROOM SIDE OF WALL, WHEREAPPLICABLE.

09 STEEL TUB WITH NEW MIXING VALVE.

10 DRAIN BOX / SUPPLY BOX PER PLUMBING.

11 WATER HEATER.

12 HIGH-EFFICIENCY FURNACE.

13 VALVE BOX. REPAIR AFFECTED LANDSCAPE AS NEEDED TO MATCH EXISTING ADJACENTLANDSCAPE CONDTIONS.

14 CLEANOUT BOX. REPAIR AFFECTED LANDSCAPE AS NEEDED TO MATCH EXISTINGADJACENT LANDSCAPE CONDITIONS.

SAME CONDITIONS AT B-C UNITS

NOTES & LEGEND - PLANS

KEY NOTES - DEMO PLAN# NOTE DESCRIPTION

01 PROTECT IN PLACE ALL EXTERIOR DOORS AND ASSOCIATED HARDWARE AND WINDOWS.

02 REMOVE FURNACE.

03 REMOVE ALL INTERIOR DOORS AND FRAMES.

04 REMOVE ALL PLUMBING FIXTURES AND ACCESSORIES.

05 REMOVE ALL CASEWORK.

06 REMOVE ALL WATER HEATERS AND EXPANSION TANKS.

07 DEMO ALL FLOOR FINISHES AND SUBFLOORING DOWN TO SLAB, AND ABATE ALLASBESTOS-CONTAINING MATERIAL.

08 DEMO WALL AND CEILING FINISHES AND SUBSTRATES DOWN TO FRAMING AS NEEDED TOACCESS PLUMBING, AND ABATE ALL ASBESTOS-CONTAINING MATERIAL.

09 SAW CUT CONCRETE SLAB AS NEEDED TO REPLACE WASTE PIPING. FIELD VERIFYLOCATION OF PIPING PRIOR TO CUTTING SLAB.

10 REMOVE LANDSCAPE AS NEEDED FOR NEW VALVE BOX.

11 REMOVE LANDSCAPE AS NEEDED FOR NEW CLEANOUT BOX.

SAME CONDITIONS AT B-C UNITS

1/4" = 1'-0"1

UNIT TYPE B - ENLARGED DEMO FLOOR PLAN

1/4" = 1'-0"2

UNIT TYPE B - ENLARGED FLOOR PLAN

REVISION SCHEDULE

Page 5: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

BEDROOM

BEDROOM

KITCHEN

LIVING

MECH ROOM

WH

BATH

CLOSET /

STORAGE

STORAGE

ENTRY

BEDROOM

DINING

OUTSIDE

STOREROOM

FURNACE

09080705040301

02

06

10

11

BEDROOM

BEDROOM

KITCHEN

LIVING

MECH ROOM

WH

BATH

CLOSET /

STORAGE

STORAGE

ENTRY

BEDROOM

DINING

OUTSIDE

STOREROOM

FURNACE05

04

3A02.01

CLG

4A02.01

FLR

06

06

10

11

01 02 03

05

04

08

09

13

10

12W01

W01

14

1. REFERENCE PLUMBING DRAWINGS FOR INFORMATION ON PLUMBING ELEMENTS AND SYSTEMS.2. REFERENCE FOR INTERIOR WALL ASSEMBLIES. WALL ASSEMBLY TYPE W02 IS

TYPICAL, UNLESS NOTED OTHERWISE.

TYPICAL ROOM TAG

ANNOTATION TAG

CONSTRUCTION ELEMENTS

ROOM NAME

EXISTING SLAB TO BE CUT AND PATCHED

EXISTING ELEMENT TO REMAIN

DEMOLISHED ELEMENT EXISTING FLOORING TO BE REMOVED AND REPLACED

NEW POURED-IN-PLACE CONCRETE SLAB

NEW ELEMENT

COVER PLATE ON UNDERSIDE OF CEILING

1. OWNER WILL COORDINATE TENANT RELOCATION PRIOR TO BEGINNING WORK.

2. OWNER TO REMOVE AND STORE EXISTING FURNITURE, APPLIANCES, AND EQUIPMENT PRIOR TO BEGINNING WORK.

3. OWNER TO FURNISH & INSTALL:A. ALL PLUMBING FIXTURES, EXCEPT TUB

AND SHOWER VALVE.B. SUPPLY LINES AND P-TRAPSC. PLUMBING FIXTURES AND CASEWORKD. ALL WALL AND FLOOR FINISHES AND

TRIME. ALL INTERIOR DOORS, FRAMES, AND

HARDWARE

OWNER SCOPE CONTRACTOR SCOPE

1. COORDINATE WORK PLAN SEQUENCING WITH OWNER PRIOR TO BEGINNING WORK.

2. FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO BEGINNING WORK.

3. PRESERVE AND PROTECT EXISTING BUILDING SYSTEMS TO REMAIN.

4. COMPLY WITH LAWS AND REGULATIONS REGARDING HAZARDOUS MATERIALS WHERE HAZARDOUS MATERIALS ARE DISCOVERED DURING REMOVAL OPERATIONS AND AS INDICATED IN ADDITIONAL BID REPORTS. HAZARDOUS MATERIALS INCLUDE REGULATED ASBESTOS CONTAINING MATERIALS, LEAD, PCB'S, AND MERCURY.

5. CONTRACTOR TO FURNISH AND INSTALL SHOWER VALVE ROUGH-IN, TRIM, AND TUB.

NOTES

1 / A02.01

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET

01/24/2020

A26.02

TYPICAL UNIT PLANS -

TYPE D

YO

UN

GS

LA

KE

115T

H L

AN

E S

ER

EN

TO

N, W

AS

HIN

GT

ON

980

55

KIN

G C

OU

NT

Y H

OU

SIN

G A

UT

HO

RIT

Y

1/4" = 1'-0"1

UNIT TYPE D - ENLARGED DEMO FLOOR PLAN

1/4" = 1'-0"2

UNIT TYPE D - ENLARGED FLOOR PLAN

NOTES & LEGEND - PLANS

KEY NOTES - FLOOR PLAN# NOTE DESCRIPTION

01 PROVIDE CLEANOUTS FOR ALL WASTE PIING AND UNDER ALL EXISTING SINK LOCATIONS.

02 PROVIDE ROUGH-INS FOR ALL PLUMBING FIXTURES.

03 PATCH GWB AT PLUMBING ACCESS POINTS. PROVIDE TAPE, MUD, AND TEXTURE.

04 POURED-IN-PLACE CONCRETE SLAB TO ALIGN WITH EXISTING ADJACENT FLOOR SLAB.

05 EXPOSED PIPING TO RUN TIGHT AGAINST THE BOTTOM OF THE CEILING AND ADJACENTWALLS. PROVIDE COVER PLATE OVER EXPOSED PIPING CONDUIT ON UNDERSIDE OFCEILING.

06 RUN DOMESTIC PIPING VERTICALLY WITHIN WALL.

07 PIPE CHASE.

08 ACCESS PANEL. LOCATE ACCESS PANEL ON STORAGE ROOM SIDE OF WALL, WHEREAPPLICABLE.

09 STEEL TUB WITH NEW MIXING VALVE.

10 DRAIN BOX / SUPPLY BOX PER PLUMBING.

11 WATER HEATER.

12 HIGH-EFFICIENCY FURNACE.

13 VALVE BOX. REPAIR AFFECTED LANDSCAPE AS NEEDED TO MATCH EXISTING ADJACENTLANDSCAPE CONDTIONS.

14 CLEANOUT BOX. REPAIR AFFECTED LANDSCAPE AS NEEDED TO MATCH EXISTINGADJACENT LANDSCAPE CONDITIONS.

KEY NOTES - DEMO PLAN# NOTE DESCRIPTION

01 PROTECT IN PLACE ALL EXTERIOR DOORS AND ASSOCIATED HARDWARE AND WINDOWS.

02 REMOVE FURNACE.

03 REMOVE ALL INTERIOR DOORS AND FRAMES.

04 REMOVE ALL PLUMBING FIXTURES AND ACCESSORIES.

05 REMOVE ALL CASEWORK.

06 REMOVE ALL WATER HEATERS AND EXPANSION TANKS.

07 DEMO ALL FLOOR FINISHES AND SUBFLOORING DOWN TO SLAB, AND ABATE ALLASBESTOS-CONTAINING MATERIAL.

08 DEMO WALL AND CEILING FINISHES AND SUBSTRATES DOWN TO FRAMING AS NEEDED TOACCESS PLUMBING, AND ABATE ALL ASBESTOS-CONTAINING MATERIAL.

09 SAW CUT CONCRETE SLAB AS NEEDED TO REPLACE WASTE PIPING. FIELD VERIFYLOCATION OF PIPING PRIOR TO CUTTING SLAB.

10 REMOVE LANDSCAPE AS NEEDED FOR NEW VALVE BOX.

11 REMOVE LANDSCAPE AS NEEDED FOR NEW CLEANOUT BOX.

SAME CONDITIONS AT D-2 & D-3 UNITS

SAME CONDITIONS AT D-2 & D-3 UNITS

REVISION SCHEDULE

Page 6: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

1. REFERENCE PLUMBING DRAWINGS FOR INFORMATION ON PLUMBING ELEMENTS AND SYSTEMS.2. REFERENCE FOR INTERIOR WALL ASSEMBLIES. WALL ASSEMBLY TYPE W02 IS

TYPICAL, UNLESS NOTED OTHERWISE.

TYPICAL ROOM TAG

ANNOTATION TAG

CONSTRUCTION ELEMENTS

ROOM NAME

EXISTING SLAB TO BE CUT AND PATCHED

EXISTING ELEMENT TO REMAIN

DEMOLISHED ELEMENT EXISTING FLOORING TO BE REMOVED AND REPLACED

NEW POURED-IN-PLACE CONCRETE SLAB

NEW ELEMENT

COVER PLATE ON UNDERSIDE OF CEILING

1. OWNER WILL COORDINATE TENANT RELOCATION PRIOR TO BEGINNING WORK.

2. OWNER TO REMOVE AND STORE EXISTING FURNITURE, APPLIANCES, AND EQUIPMENT PRIOR TO BEGINNING WORK.

3. OWNER TO FURNISH & INSTALL:A. ALL PLUMBING FIXTURES, EXCEPT TUB

AND SHOWER VALVE.B. SUPPLY LINES AND P-TRAPSC. PLUMBING FIXTURES AND CASEWORKD. ALL WALL AND FLOOR FINISHES AND

TRIME. ALL INTERIOR DOORS, FRAMES, AND

HARDWARE

OWNER SCOPE CONTRACTOR SCOPE

1. COORDINATE WORK PLAN SEQUENCING WITH OWNER PRIOR TO BEGINNING WORK.

2. FIELD VERIFY EXISTING CONDITIONS. NOTIFY ARCHITECT OF ANY DISCREPANCY PRIOR TO BEGINNING WORK.

3. PRESERVE AND PROTECT EXISTING BUILDING SYSTEMS TO REMAIN.

4. COMPLY WITH LAWS AND REGULATIONS REGARDING HAZARDOUS MATERIALS WHERE HAZARDOUS MATERIALS ARE DISCOVERED DURING REMOVAL OPERATIONS AND AS INDICATED IN ADDITIONAL BID REPORTS. HAZARDOUS MATERIALS INCLUDE REGULATED ASBESTOS CONTAINING MATERIALS, LEAD, PCB'S, AND MERCURY.

5. CONTRACTOR TO FURNISH AND INSTALL SHOWER VALVE ROUGH-IN, TRIM, AND TUB.

NOTES

1 / A02.01

LIVING BEDROOM

STORAGE

BEDROOM

BEDROOM

BATH

STORAGE

WHFURNACE

MECH ROOM

STORAGE

ENTRYKITCHEN

STORAGE

LINEN

OUTSIDE

STOREROOM

DINING

09ALTERNATE ROUTING OF WASTE PIPING

0905 0201 03 04

06

07 08

10

ALTERNATE ROUTING CLEANOUT BOX

11

11

LIVING BEDROOM

STORAGE

BEDROOM

BEDROOM

BATH

STORAGE

WHFURNACE

MECH ROOM

STORAGE

ENTRYKITCHEN

STORAGE

LINEN

OUTSIDE

STOREROOM

DINING

05

04

04

05

05

3A02.01

CLG

4A02.01

FLR

ALTERNATE ROUTING OF WASTE PIPING

09

13

08

08

06

01 02 03

10

11

10

12

W01

14

14

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET

01/24/2020

A26.03

TYPICAL UNIT PLANS -

TYPE E & E-C

YO

UN

GS

LA

KE

115T

H L

AN

E S

ER

EN

TO

N, W

AS

HIN

GT

ON

980

55

KIN

G C

OU

NT

Y H

OU

SIN

G A

UT

HO

RIT

Y

NOTES & LEGEND - PLANS

SAME CONDITIONS AT E-C UNITS

SAME CONDITIONS AT E-C UNITS

KEY NOTES - FLOOR PLAN# NOTE DESCRIPTION

01 PROVIDE CLEANOUTS FOR ALL WASTE PIING AND UNDER ALL EXISTING SINK LOCATIONS.

02 PROVIDE ROUGH-INS FOR ALL PLUMBING FIXTURES.

03 PATCH GWB AT PLUMBING ACCESS POINTS. PROVIDE TAPE, MUD, AND TEXTURE.

04 POURED-IN-PLACE CONCRETE SLAB TO ALIGN WITH EXISTING ADJACENT FLOOR SLAB.

05 EXPOSED PIPING TO RUN TIGHT AGAINST THE BOTTOM OF THE CEILING AND ADJACENTWALLS. PROVIDE COVER PLATE OVER EXPOSED PIPING CONDUIT ON UNDERSIDE OFCEILING.

06 RUN DOMESTIC PIPING VERTICALLY WITHIN WALL.

07 PIPE CHASE.

08 ACCESS PANEL. LOCATE ACCESS PANEL ON STORAGE ROOM SIDE OF WALL, WHEREAPPLICABLE.

09 STEEL TUB WITH NEW MIXING VALVE.

10 DRAIN BOX / SUPPLY BOX PER PLUMBING.

11 WATER HEATER.

12 HIGH-EFFICIENCY FURNACE.

13 VALVE BOX. REPAIR AFFECTED LANDSCAPE AS NEEDED TO MATCH EXISTING ADJACENTLANDSCAPE CONDTIONS.

14 CLEANOUT BOX. REPAIR AFFECTED LANDSCAPE AS NEEDED TO MATCH EXISTINGADJACENT LANDSCAPE CONDITIONS.

KEY NOTES - DEMO PLAN# NOTE DESCRIPTION

01 PROTECT IN PLACE ALL EXTERIOR DOORS AND ASSOCIATED HARDWARE AND WINDOWS.

02 REMOVE FURNACE.

03 REMOVE ALL INTERIOR DOORS AND FRAMES.

04 REMOVE ALL PLUMBING FIXTURES AND ACCESSORIES.

05 REMOVE ALL CASEWORK.

06 REMOVE ALL WATER HEATERS AND EXPANSION TANKS.

07 DEMO ALL FLOOR FINISHES AND SUBFLOORING DOWN TO SLAB, AND ABATE ALLASBESTOS-CONTAINING MATERIAL.

08 DEMO WALL AND CEILING FINISHES AND SUBSTRATES DOWN TO FRAMING AS NEEDED TOACCESS PLUMBING, AND ABATE ALL ASBESTOS-CONTAINING MATERIAL.

09 SAW CUT CONCRETE SLAB AS NEEDED TO REPLACE WASTE PIPING. FIELD VERIFYLOCATION OF PIPING PRIOR TO CUTTING SLAB.

10 REMOVE LANDSCAPE AS NEEDED FOR NEW VALVE BOX.

11 REMOVE LANDSCAPE AS NEEDED FOR NEW CLEANOUT BOX.

1/4" = 1'-0"1

UNIT TYPE E - ENLARGED DEMO FLOOR PLAN

1/4" = 1'-0"2

UNIT TYPE E - ENLARGED FLOOR PLAN

REVISION SCHEDULE

Page 7: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

E

BALANCING COCK (BC)

BALL VALVE

EXISTING (E) PIPING

GLOBE VALVE

CHECK VALVE (CV)

GATE VALVE (GV)

PIPE DOWN

PIPE UP

PRESSURE REDUCING VALVE

CROSSING LINES, NON CONNECTING

FLOOR DRAIN

ELBOWS, 90° & 45°

CAP

TEE

FLUSH CLEANOUT (FCO/SCO)

IN LINE WASTE CONNECTION

P-TRAP

BRANCH PIPE DOWN

BRANCH PIPE UP

TEE & UP

CLEAN OUT (CO)

WASTE OR VENT UP

WALL CLEANOUT

DOMESTIC HOT WATER (HW)

NATURAL GAS

VENT (V), OR HIDDEN BELOW WASTE

DOMESTIC COLD WATER (CW)

SOIL, WASTE (S, W)

PIPE CONTINUATION

MECHANICAL LEGENDPLUMBING

SYMBOL DESCRIPTION SYMBOL DESCRIPTION

ELECTRICAL CONTRACTOR

POINT OF CONNECTION

MECHANICAL CONTRACTORMC

EC

POC

GENERAL CONTRACTORGC

BELOW FINISHED FLOORBFF

ABOVE FINISHED FLOORAFF

G

W

DEMOLISHED PIPING

PROJECT SCOPE1. CONTRACTOR TO FIELD LOCATE AND REPLACE ALL EXISTING DOMESTIC

WATER PIPING AND WASTE PIPING WITHIN 5' OF THE BUILDING.

2. CONTRACTOR FIELD LOCATE ALL EXISTING WASTE PIPING AS SHOWN ANDREPLACE.

3. EXTENT OF EXTERIOR WASTE REPLACEMENT IS SHOWN ON P1.01.

4. CONTRACTOR TO REPLACE ALL DOMESTIC PIPING WITH EACH HOUSINGUNIT.

5. ALL NEW DOMESTIC WATER PIPING IN RESTROOMS TO HAVE ROUGH-INWITHIN INTERIOR WALLS.

6. CONTRACTOR TO FIELD LOCATE ALL DOMESTIC PIPING AND WASTE PIPINGON SITE BEFORE COMMENCEMENT OF WORK.

7. EXISTING WATER HEATER AND EXPANSION TANK TO BE DEMOLISHED ANDREPLACED AS SCHEDULED.

8. EXISTING GAS FURNACE TO BE DEMOLISHED AND REPLACED WITH A HIGHEFFICIENCY GAS FURNACE.

FINISHED FLOORCOMBUSTION AIRSTACK SUPPORT.

DRAIN VALVE (TYPICAL)

G

3" ABS

2"ABS TO ROOF

SIZE PER PLANSHW TO FIXTURES

SIZE PER PLANS

(TYPICAL)GAS-SIZE PER PLANS

GAS COCK (TYPICAL)

(TYPICAL)DIRT LEG, 6" MIN.

FULL SIZE ANDRUN RELIEF PIPING

(TYP)

3" CONCENTRIC FLUE, INSTALL PERMANUFACTURERS RECOMMENDATIONS(TYPICAL)

G

DOUBLE CHECKVALVE

(TYPICAL)

SEISMIC STRAPS(TYPICAL)

CW FROM METEREXISTING NATURAL GAS

COND

TERMINATE DIRECTLYABOVE DRIP PAN (TYP)

DRIP PAN (TYP)

T

(TYP)

ROUTE CONDENSATE TODRAIN PER PLANS

1.

NOTES:

PROVIDE TRANSITIONS FROM EXISTING

SCALE:3 WATER HEATER PIPING DETAILNTSSCALE:1 TYPICAL VERTICAL INDOOR GAS FURNACE INSTALLATION DETAIL

NTS

DUCTWORK TO NEW GAS FURNACE.

2" FILTER ACCESS

EXISTING DUCTWORK

EXISTING DUCTWORK

COMBUSTION AND VENTPIPING UP TO CONCENTRICVENT.

GF1

WH1

G

MECH ROOM 96%100

EFFICIENCY

100 680

REMARKSLOCATION

50

GAS-FIRED WATER HEATER SCHEDULE

NOTES FOR GAS-FIRED WATER HEATER SCHEDULE

AO SMITHHWT-1 GDHE-50 5 120 1

MFR. MODEL ELECTRICAL

MCA VOLTS Ø

1 1 2 4

1

2

3

STARTERFURN. BY

DISCONNECTFURN. BY

UNITNO

TANK SIZE(GAL)

INPUTMBH

RECOVERY (GPH) @90°F RISE

WET WEIGHT(LB)

SINGLE POINT POWER CONNECTION. EC TO PROVIDE DISCONNECT.

SET TEMPERATURE AT 120° F.

WATER HEATER SHALL CONFORM WITH ESDS REQUIREMENTS FOR EFFICIENCY AND TANK INSULATION REQUIREMENTS.

PROVIDE WITH ACID NEUTRALIZER KIT.

THERMAL

4

MFR.UNITNO MODEL TYPE

TOTAL

EXPANSION TANK SCHEDULEVOLUME (GAL)

ACCEPTANCEREMARKSCONFIGURATION PRESSURE

(PSI)

CONTRACTOR TO SET AIR PRESSURE IN FIELD. SET TO EQUAL INCOMING WATER PRESSURE.

MAXIMUM PRESSURE RATING OF 150 PSI.

WEIGHT

1

SERVICE (LBS)

2

ET-1 250ST-5 0.9DIAPHRAGM 1 2AMTROL VERTICAL DOMESTIC HWT-1 15

NOTES FOR EXPANSION TANK SCHEDULE

GAS-FIRED FURNACE SCHEDULE

S9X1B040U3PSBA

UNIT

GF-1

NO MFR.

TRANE

LOCATIONMODEL

MECH ROOM

MCAWEIGHT

(lbs)

150 8.8

VOLTS

15

MOP

120 1

Ø

AUX. ELECTRICAL

FURN. BYDISCONNECT STARTER

MFR

FURN. BY

EC

DUCT SMOKEDETECTORFURN. BY

EC

MBH

BURNER

38.8

BLOWER

1/2VARIABLE0.510751200 6.4

HPCONTROLSPEED

SP.EXT.CFM FLA STAGE

2

NOTESAFUE

96%

NOTES FOR GAS-FIRED FURNACE SCHEDULE1

2

PROVIDE UNIT WITH A SINGLE POINT POWER CONNECTION.

PROVIDE WITH MANUFACTURER'S CONCENTRIC VENTING KIT.

PROVIDE WITH ACID NEUTRALIZATION KIT.

RPM

1 2

ET1

3

3

3

2. INSTALL PER MANUFACTURER'SRECOMMENDATIONS AND REQUIREMENTS

1.

NOTES:

INSTALL PER MANUFACTURER'SRECOMMENDATIONS AND REQUIREMENTS

STRUCTURALLY RATED STAND

CONDENSATE TO DRAINPER PLANS

FLUE CAP

INTAKETERMINATION.

BOTTOM OF FLUECAP SHALL BE 24"MIN ABOVE ANYROOF WITHIN 10'

SHEATHING

DOUBLE WALL FOREXHAUST FLUE

PROVIDE INTAKE PORTIONWITH NET FREE AREA EQUALTO INTAKE DUCT AREAINTAKE DUCT SIZE ACCORDINGTO MANUFACTURER'SRECOMMENDATIONS

NON HARDENINGCAULK

FLASHING

EXHAUST FLUE SIZEACCORDING TOMANUFACTURER'SRECOMMENDATIONS

NOTES1. VERIFY PITCH OF ROOF AND PROVIDE BLOCKING AND FLASHING AS REQUIRED.2. COORDINATE EQUIPMENT AND FLUE LOCATION WITH GENERAL CONTRACTOR.

SCALE:2

CONCENTRIC FLUE ROOFPENETRATION DETAIL

DIAGRAMMATIC

FLUE CAP

INTAKETERMINATION.

BOTTOM OF FLUECAP SHALL BE 24"MIN ABOVE ANYROOF WITHIN 10'

SHEATHING

DOUBLE WALL FOREXHAUST FLUE

PROVIDE INTAKE PORTIONWITH NET FREE AREA EQUALTO INTAKE DUCT AREAINTAKE DUCT SIZE ACCORDINGTO MANUFACTURER'SRECOMMENDATIONS

NON HARDENINGCAULK

FLASHING

EXHAUST FLUE SIZEACCORDING TOMANUFACTURER'SRECOMMENDATIONS

NOTES1. VERIFY PITCH OF ROOF AND PROVIDE BLOCKING AND FLASHING AS REQUIRED.2. COORDINATE EQUIPMENT AND FLUE LOCATION WITH GENERAL CONTRACTOR.

2" MIN. CLR

12"

24"

MANUFACTURER AND MODEL NUMBERSFIXTURE MOUNTING W V HW CW

PLUMBING FIXTURE SCHEDULE REMARKSUNIT

NO

P-1 FLOOR 2"COMBINATION

CONTRACTOR TO VERIFY LEFT OR RIGHT DRAINORIENTATION PRIOR TO ORDERING STALL ANDSURROUND. DISCHARGE TEMPERATURE SHALL NOTEXCEED 120°F. COORDINATE GRAB HANDLES ANDSEATS WITH ARCHITECTURAL DOCUMENTS.

TUB SHOWER ADA11

2" 12" 1

2"ENCLOSURE: EL MUSTEE DURAWALL 350WHTCONTROLS: MOEN CHATEU L2369 EPDRAIN: HD SUPPLY #: 692401

BASIN: AMERICAN STANDARD PRINCETON

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET12/18/2019

YOUN

GS LA

KE18

923 1

15TH

LANE

SE

RENT

ON, W

ASHI

NGTO

N 98

055

KING

COU

NTY

HOUS

ING

AUTH

ORIT

Y

REVISION SCHEDULE

01/15/2019

P0.01

LEGEND, SCHEDULES,DETAILS

EXISTING NATURAL GAS LINE

01/24/2020

Page 8: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

116TH AVENUE SESE

189T

H LA

NE

SE 189TH LANE

EC

EXISTINGPLAYGROUND

SE 18

9TH

LANEEXISTING LAWN &

LANDSCAPING

PROPERTY LINE = 131.26'

PR

OP

ER

TY

LIN

E =

165.04'

PROPERTY LINE = 568.96'

PROPERTY LINE = 360.00'

PR

OP

ER

TY

LIN

E =

462.67'

PROPERTY LINE = 371.67'

PR

OP

ER

TY

LIN

E =

299.86'

PROPERTY LINE = 440.00'

EXISTINGLANDSCAPING

EXISTING CHAINLINKFENCING, TYP

EC

EC

EC

EC EC EC

ECEC EC

E

BC

BC BC BC B B

B

E

D-2

D-3

D-3

D-2

D-3

D-2

D-3

EC

EC

EXISTINGBUS STOP

EXISTINGBUS STOP

TYPICALCLEANOUT

CONSTRUCTION NOTESEXISTING WASTE.

NEW WASTE SIZE PER PLANS.

NEW DOMESTIC WATER SIZE PER PLANS.

EXISTING DOMESTIC WATER.

APPROXIMATE LOCATION OF EXISTING ABANDONED SEPTIC TANK TO BEDECOMMISSIONED BY THE CONTRACTOR.

1

2

3

4

11

1

1

1

1

1

1

1

1

1

11

1

1

1

2

2 22

2

2

2

2

2

222

2

2

2

2

2

2

2

2

2 2

34

3

4

3

4

3

4

3

4

3

43

4

3

4

3

4

3

4

3

4

3

4

3

4

3

4

3

4

3

4

34

3

4

3

43

4

34

3

43

4

3

4

3

4

3

4

3

43

4

5

GENERAL NOTES1. CONTRACTOR SHALL FIELD LOCATE SEPTIC TANKS AND REPORT, WITH

DOCUMENTATION, THE LOCATION DISCREPANCIES TO THE OWNER'S REPRESENTATIVE.

2. CONTRACTOR TO DECOMMISSIONING SEPTIC TANKS IN ACCORDANCE WITHKING COUNTY'S REQUIREMENTS AND SUBMIT TO THE OWNER'S REPRESENTATIVE ON THE MEANS AND METHODS OF DECOMMISSIONING THESEPTIC TANKS.

3. THE CONTRACTOR HIRED TO DECOMMISSION THE ABANDONED SEPTIC TANKSSHALL PROVIDE AND SUBMIT ALL DOCUMENTATION TO KING COUNTY ASREQUIRED TO MEET THEIR REQUIREMENTS AND PROCURE ANY REQUIREDPERMITS.

4. ALL SOILS THAT ARE EXCAVATED SHALL BE REMOVED FROM THE SITE ANDNEW CLEAN FILL SHALL BE UTILIZED.

5

5

5

5

5

5

5

5 55

5

5

5

5 5 5

5

5

5

5 55 5 5

5

5

5

5

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET12/18/2019

YOUN

GS LA

KE18

923 1

15TH

LANE

SE

RENT

ON, W

ASHI

NGTO

N 98

055

KING

COU

NTY

HOUS

ING

AUTH

ORIT

Y

REVISION SCHEDULE

01/15/2019

P1.01

SITE PLAN

N

1" = 40'-0"1 SITE PLAN

1P2.01

1P2.01

1P2.01

1P2.01

1P2.01

1P2.01

1P2.01

1P2.03

1P2.02

1P2.02

1P2.02

1P2.02

1P2.02

1P2.02

1P2.03

1P2.03

1P2.03

1P2.03

1P2.03

1P2.03

1P2.03

1P2.03

1P2.03

1P2.03

ABOVE GRADEWASTE AND VENTPIPE COUPLING.EXTEND PIPING ASREQUIRED WHENINSTALLED IN BRICK

STAINLESS STEEL WALLCOVER AND SCREW.

FLOOR12" OR AS NOTED.

BELOW GRADE WASTEPIPE COUPLING.

1/8 BENDBALANCE OF PIPINGSAME AS CLEANOUTTO GRADE.

PLUGGED TEEWITH CLEANOUT

MAY EXTEND AS AWASTE OR VENT

WALL

WALL CLEANOUT (WCO)

SCALE:1CLEANOUT DETAILS

NTS

FINISH GRADE

CLEANOUT BOXES AND LID(S)

10 GA TRACER WIRE ATTACHED TOTOP OF PIPE. CONTINUOUS BETWEENCLEANOUTS. PROVIDE 12" EXTRA WIREINSIDE CLEANOUT BOX.

REMOVABLE WATERTIGHT PLUG45° BEND

FLOW FROM BUILDING

WELL COMPACTED CLASS 1 OR CLASS 2BEDDING MATERIAL PLACED AT FULL TRENCHWIDTH AND 6" MINIMUM DEPTH BELOW PIPE

DEPTH VARIESMIN. 30"

4' MAX

3" - 8" BELOWFINISHED GRADE

TWO-WAY CLEANOUT

01/24/2020

Page 9: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

REF

W

D

BEDROOM

BEDROOM

BEDROOM

STORAGE

LAV

BATH

DINING

KITCHEN

LIVING

ENTRY

STORAGE LINEN

MECHROOM

STORAGEOUTSIDE

STOREROOM

W

W2"

4"

2"

4"

4"

1" 7

UP TO EXTERNALTWO WAY CLEANOUT

7

PRESSUREREDUCING VALVE

REF

W

D

BEDROOM

BEDROOM

BEDROOM

STORAGE

LAV

BATH

DINING

KITCHEN

LIVING

ENTRY

STORAGE LINEN

MECHROOM

STORAGEOUTSIDE

STOREROOM

15

6 2

3

4

3/4"

3/4"

3/4"

13/4"

3/4"

1/2"

1/2"

RUN PIPING ALONGBEAM TRAVERSINGTHE LIVING ROOM.

OXBOX 696 SERIESDRAIN BOX ANDSUPPLY BOX WITHARRESTERS

OXBOX 696DRAIN BOX

9

9

GF1

WH1

7

CONSTRUCTION NOTESPIPING ROUTED OUT OF THE MECHANICAL ROOM TO BE RAN BELOW THE CEILINGAND PROVIDED WITH A COVER PLATE EXTENDING THE LENGTH OF THE PIPINGEXPOSED IN OTHER SPACES.

DROP PIPING VERTICALLY THROUGH NEW PIPE CHASE PER ARCHITECTURAL. RUNHORIZONTALLY THROUGH WALL TO SINK AND WASHING MACHINE.

DOMESTIC WATER SHUTOFF TO BE RELOCATED FROM THE EXTERIOR TO THE MAINRISER. PROVIDE OFFSET TO MAKE ISOLATION VALVE ACCESSIBLE.

PROVIDE ISOLATION VALVE IN DROP TO HOSE BIBB.

PROVIDE ACCESS PANEL FOR ISOLATION VALVE.

PIPING TO RUN TO WASHING MACHINE, KITCHEN SINK, AND WASHING MACHINE FORDOMESTIC COLD WATER AND HOT WATER AT 1/2" PIPE.

12" DEEP LOCKING LID VALVE BOX.

ROUTE 2" DRAIN TO ADJACENT WASTE LINES IN THE RESTROOM. PROVIDE WITHTRAP AND ROUTE 1-12" VENT TO ADJACENT VENT LINE IN THE RESTROOM WE TALL.

COMBUSTION AIR AND VENT PIPING TO RISE TO MANUFACTURER'S CONCENTRICVENT KIT.

1

2

3

GENERAL NOTES1. WASTE PIPING SHOWN IS A FULL REPLACEMENT OF THE EXISTING WASTE

PIPING. PROVIDE NEW P-TRAPS AND TOILET FLANGES. TOILET WAX SEAL ISOWNER PROVIDED.

2. ALL EXISTING PIPING INCLUDING EXISTING PEX PIPING SHALL BE DEMOLISHED AND REPLACED.

3. WHERE EXISTING DOMESTIC PIPING RUNS BELOW SLAB ABANDON IN PLACEAND CAP.

4. CONTRACTOR TO PROVIDE ROUGH-INS FOR ALL FIXTURES. TUB ANDSHOWER VALVE SHALL BE CONTRACTOR INSTALLED. ALL OTHER FIXTURESTO BE INSTALLED BY OTHERS.

4

5

6

7

8

9

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET12/18/2019

YOUN

GS LA

KE18

923 1

15TH

LANE

SE

RENT

ON, W

ASHI

NGTO

N 98

055

KING

COU

NTY

HOUS

ING

AUTH

ORIT

Y

REVISION SCHEDULE

01/15/2019

P2.01

UNIT TYPE B

1/4" = 1'-0"UNIT TYPE B - ENLARGED FOUNDATION PLAN

1/4" = 1'-0"UNIT TYPE B - ENLARGED FLOOR PLAN

1

2

P-1

01/24/2020

Page 10: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

D

W

REF

BEDROOM

BEDROOM

KITCHEN

LIVING

MECH ROOM

BATH

CLOSET /STORAGE

STORAGE

ENTRY

BEDROOM

DINING

OUTSIDESTOREROOM

W W W

WW

4"2"

4"

2"

2"

2"

1"

2"

6

UP TO EXTERNALTWO WAY CLEANOUT

6

PRESSUREREDUCING VALVE

D

W

REF

BEDROOM

BEDROOM

KITCHEN

LIVING

MECH ROOM

BATH

CLOSET /STORAGE

STORAGE

ENTRY

BEDROOM

DINING

OUTSIDESTOREROOM

12

3

1/2"

1/2"

3/4"

1/2"

RUN PLUMBING INCOUNTER TOP WALL 1

3/4"

4

5

6

OXBOX 696 SERIESDRAIN BOX ANDSUPPLY BOX WITHARRESTERS

OXBOX 696DRAIN BOX

GF1

WH1

7

8

8

6

CONSTRUCTION NOTESPIPING ROUTED OUT OF THE MECHANICAL ROOM TO BE RAN BELOW THE CEILINGAND PROVIDED WITH A COVER PLATE EXTENDING THE LENGTH OF THE PIPINGEXPOSED IN OTHER SPACES.

DROP PIPING VERTICALLY THROUGH NEW PIPE CHASE PER ARCHITECTURAL. RUNHORIZONTALLY THROUGH WALL TO SINK AND WASHING MACHINE.

DOMESTIC WATER SHUTOFF TO BE RELOCATED FROM THE EXTERIOR TO THE MAINRISER. PROVIDE OFFSET TO MAKE ISOLATION VALVE ACCESSIBLE.

DROP DOMESTIC PIPING TO EXISTING WASHER BOX SUPPLY STOPS.

PROVIDE ACCESS PANEL FOR ISOLATION VALVE.

12" DEEP LOCKING LID VALVE BOX.

ROUTE 2" DRAIN TO ADJACENT WASTE LINES IN THE RESTROOM WET WALL.PROVIDE WITH TRAP AND ROUTE 1-12" VENT TO ADJACENT VENT LINE IN THERESTROOM WE TALL.

COMBUSTION AIR AND VENT PIPING TO RISE TO MANUFACTURER'S CONCENTRICVENT KIT.

1

2

3

GENERAL NOTES1. WASTE PIPING SHOWN IS A FULL REPLACEMENT OF THE EXISTING WASTE

PIPING. PROVIDE NEW P-TRAPS AND TOILET FLANGES. TOILET WAX SEAL ISOWNER PROVIDED.

2. ALL EXISTING PIPING INCLUDING EXISTING PEX PIPING SHALL BE DEMOLISHED AND REPLACED.

3. FIELD LOCATE HOSE BIBBS AND PROVIDE 3/4" DOMESTIC COLD WATER WITHISOLATION VALVE.

4. WHERE EXISTING DOMESTIC PIPING RUNS BELOW SLAB ABANDON IN PLACEAND CAP.

5 CONTRACTOR TO PROVIDE ROUGH-INS FOR ALL FIXTURES. TUB ANDSHOWER VALVE SHALL BE CONTRACTOR INSTALLED. ALL OTHER FIXTURESTO BE INSTALLED BY OTHERS.

6 CONTRACTOR SHALL CONNECT NEW WASTE PIPING TO EXISTING VENTPIPING.

4

5

6

7

8

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET12/18/2019

YOUN

GS LA

KE18

923 1

15TH

LANE

SE

RENT

ON, W

ASHI

NGTO

N 98

055

KING

COU

NTY

HOUS

ING

AUTH

ORIT

Y

REVISION SCHEDULE

01/15/2019

P2.02

UNIT TYPE D

1/4" = 1'-0"1 UNIT TYPE D - ENLARGED FOUNDATION PLAN

1/4" = 1'-0"2 UNIT TYPE D - ENLARGED FLOOR PLAN

P-1

01/24/2020

Page 11: KING COUNTY HOUSING AUTHORITY · 2020-02-06 · rice fergus miller 275 5th st, suite 100 bremerton, wa 98337 architect gregory belding, architect of record (360) 362 -1429 gbelding@rfmarch.com

D REF

W

LIVING BEDROOM

STORAGE

BEDROOM

BEDROOM

BATH

STORAGEMECH ROOM

STORAGE

ENTRYKITCHEN

STORAGE

LINEN

OUTSIDESTOREROOM

DINING

W

W

W W

4"2"

4"

2"

4"

2" 2"

2"

2"

DASHED LINESREPRESENT ALTERNATEROUTING. SEE SITE PLANFOR ROUTING REQUIRED.

1" UP TO EXTERNALTWO WAY CLEANOUT

UP TO EXTERNALTWO WAY CLEANOUT

6

6

PRESSUREREDUCING VALVE

D REF

W

LIVING BEDROOM

STORAGE

BEDROOM

BEDROOM

BATH

STORAGEMECH ROOM

STORAGE

ENTRYKITCHEN

STORAGE

LINEN

OUTSIDESTOREROOM

DINING

1

3

1 1/2"

4

1

3/4"

3/4"

3/4"1/2"

2

RUN PLUMBING INCOUNTER TOP WALL

3/4"

5

6

GF1

WH1

OXBOX 696 SERIESDRAIN BOX ANDSUPPLY BOX WITHARRESTERS

OXBOX 696DRAIN BOX

7

8

8

6

CONSTRUCTION NOTESPIPING ROUTED OUT OF THE MECHANICAL ROOM TO BE RAN BELOW THE CEILINGAND PROVIDED WITH A COVER PLATE EXTENDING THE LENGTH OF THE PIPINGEXPOSED IN OTHER SPACES.

DROP PIPING VERTICALLY THROUGH NEW PIPE CHASE PER ARCHITECTURAL. RUNHORIZONTALLY THROUGH WALL TO SINK AND WASHING MACHINE.

DOMESTIC WATER SHUTOFF TO BE RELOCATED FROM THE EXTERIOR TO THE MAINRISER. PROVIDE OFFSET TO MAKE ISOLATION VALVE ACCESSIBLE.

PROVIDE ISOLATION VALVE IN DROP TO HOSE BIBB.

PROVIDE ACCESS PANEL FOR ISOLATION VALVE.

12" DEEP LOCKING LID VALVE BOX.

ROUTE 2" DRAIN TO ADJACENT WASTE LINES IN THE RESTROOM WET WALL.PROVIDE WITH TRAP AND ROUTE 1-12" VENT TO ADJACENT VENT LINE IN THERESTROOM WE TALL.

COMBUSTION AIR AND VENT PIPING TO RISE TO MANUFACTURER'S CONCENTRICVENT KIT.

1

2

3

GENERAL NOTES1. WASTE PIPING SHOWN IS A FULL REPLACEMENT OF THE EXISTING WASTE

PIPING. PROVIDE NEW P-TRAPS AND TOILET FLANGES. TOILET WAX SEAL ISOWNER PROVIDED.

2. ALL EXISTING PIPING INCLUDING EXISTING PEX PIPING SHALL BE DEMOLISHED AND REPLACED.

3. WHERE EXISTING DOMESTIC PIPING RUNS BELOW SLAB ABANDON IN PLACEAND CAP.

4. CONTRACTOR TO PROVIDE ROUGH-INS FOR ALL FIXTURES. TUB ANDSHOWER VALVE SHALL BE CONTRACTOR INSTALLED. ALL OTHER FIXTURESTO BE INSTALLED BY OTHERS.

5. CONTRACTOR SHALL CONNECT NEW WASTE PIPING TO EXISTING VENTPIPING.

4

5

6

7

8

275 FIFTH STREET, SUITE 100BREMERTON, WA 98337360-377-8773RFMARCH.COM

PROJECT #

ISSUE DATE

SHEET #

2017036.16

PERMIT/BID SET12/18/2019

YOUN

GS LA

KE18

923 1

15TH

LANE

SE

RENT

ON, W

ASHI

NGTO

N 98

055

KING

COU

NTY

HOUS

ING

AUTH

ORIT

Y

REVISION SCHEDULE

01/15/2019

P2.03

UNIT TYPE E

1/4" = 1'-0"1 UNIT TYPE E - ENLARGED FOUNDATION PLAN

1/4" = 1'-0"2 UNIT TYPE E - ENLARGED FLOOR PLAN

P-1

01/24/2020