Kiev Conference March 2 , 2013
-
Upload
kiona-burke -
Category
Documents
-
view
30 -
download
1
description
Transcript of Kiev Conference March 2 , 2013
Whats New
Kiev Conference March 2 , 2013Ken Kopp, FCLSA Paragon Vision SciencesMesa, Arizona USA
Translation : Dr. Andrey Kovalev
1 Paragon Vision SciencesWorldwide distributor of gas permeable materials since 1975Over 400 authorized laboratory customers in all continents.Entered the finished lens market with overnight Corneal Refractive Therapy (CRT) lens in June of 2002.Added the RG-4 traditional Ortho K design for the US market in 2008CRT Dual Axis design launched in 2009CRT Software offered in 2012Large diameter GP materials and finished lenses in 2012SilOWet, silicone hydrogel material , introduced in 2013
Core Products/HDS Family
Large diameter GP blanks up to 21.8 mm HDS100 onlyJust to quickly review the HDS family of materials..HDS and HDS 100 are approved for up to 7 day continuous wear Paragon Thin is a daily wear material for excellent stability for thinner spherical GP designs.And the most recent daily wear offering of HI-1.54 offers the highest index of refraction to achieve higher adds for multifocals and thinner specialty GP designs.3Core Products/Fluoroperm Family
UV available in all FluoroPerm materialsNot to forget Paragons Fluoroperm family of materials that have proven to be reliable performers over the years. FL 60 , 92, and 151 are approved for overnight wear whereas FL 30 is for daily wear only. 4Core Products/Other GP MaterialsOptacryl Dk 14
FSA 38 Dk 38
FSA 52 - Dk 52
Paraperm O2/EW O2 Dk 16 EW Dk 50
UV absorber is available in some materials. Check with your laboratory.5Core Products/Silicone HydrogelSilOWet a premium soft lens material that has the following properties;
60 Dk at 35 C
Lucifilcon A (non-ionic)
Water content 69% @ 20 C
Modulus 0.13
The SilOwet material is currently in the FDA approval process and we hope to receive approval for distribution in May of this year.6
Paragon Corneal Reshaping Products*Currently available in North America only*77Jumping from the material side of the business to the finished lens offerings. The standard CRT spherical design has been FDA approved since 2002 for myopia up to 6.00 D and with or without 1.75 D of astigmatism. The CRT Dual Axis design was introduced in 2009 as an augment for corneas with higher amounts of corneal astigmatism. The RG-4 traditional four-curve corneal reshaping design was licensed by Paragon and introduced in 2008. This product is only available in North America at this time. Introducing the CRT Software Package
The CRT Software was introduced in 2012 to offer the ability to observe the design choice based on the spectacle Rx and elevation data from the pre-treatment topography.8CRT Initial Lens Selector
The traditional lens selection has been taken from this initial lens selector slide ruler. The two data pieces that are used are the spherical manifest refraction and the flat keratometry reading. Sliding the arrow to the flat K reading and locate the manifest refraction sphere (MRS) to the right, the suggested lens parameter will be shown. This data was not from a computer algorithm but compiled from hundreds of successful patient fits over 3 years time. The accuracy of the slide ruler and the new software for initial lens selection is between 80-90 %. Once the lens is on the eye, the performance is evaluated via patient follow-up examinations.9Software Design Assist for Initial Lens Selection Accuracy
This is the screen for the spherical CRT design. The parameter offerings are the Base Curve, Return Zone Depth, Landing Zone Angle, and diameter choices. All of the parameter choices can be adjusted to maximize the tear pattern for the initial lens parameter selection.10CRT Software FeaturesImport patient files from the topographer Candidate selection for a specific design
Ability to manipulate parameters for optimum tear patterns
Electronic ordering (international distributors pending)Compatibility LinksKeratron Scout/Piccalo
Medmont Studio 4/5
Oculus EasyGraph/Keratograph
Humphrey Atlas 900 Series, CZM Atlas Model 9000, Tomey versions 1-4, and Pentacam files can be imported to the CRT software but not linked directly to the unit.CRT Design Choice
Simulated Tear Pattern With Initial Lens Parameters - CRT
Simulated Tear Pattern With Initial Lens Parameters CRT DA
Incomplete/Apical Astigmatic Pattern
The Spherical and Dual Axis CRT designs have the same FDA approval for astigmatism.up to 1.75 D. The shape of the astigmatic pattern from the pre-treatment topography can be an important factor as to which design is best to begin with. An Apical pattern with 1.75 D of astigmatism, seen in the upper left hand picture, that is enclosed in the 6 mm treatment zone can be successful using the standard spherical design. A optimum tear pattern and centration is achieved as shown in the upper right hand picture. The image at the bottom shows the desired tear layer under the lens using this design on the cornea that is astigmatic but successful with the spherical design. 16
Limbus-to-Limbus Astigmatic Pattern
This astigmatic pattern taken from the pre-treatment map shows the steeper meridian extending from limbus-to-limbus. The spherical CRT design does not allow the appropriate peripheral alignment in the steeper meridian. The result is a decentered lens and inadequate peripheral bearing in all meridans.17
CRT Dual Axis on Astigmatic Eye
This is a CRT Dual Axis lens on the same cornea that shows the limbus-to-limbus astigmatic pattern. The design offers a peripheral alignment for the flat and steep meridians of the cornea and allows the proper tear pattern for proper centration and complete treatment.18Freedom to Alter Tear Pattern for Optimum AppearanceChange all parameters BC/RZD/LZA/Diameter
Rotate Dual Axis design to observe tear pattern changes
Reset button to return to original settings and/or click OK to begin ordering sequence or return to the home page
Paragon Software SummaryCompatible with multiple topographers
Specific design selection for CRT/Dual Axis/RG4
Variable simulated tear patterns
Electronic Ordering
Large Diameter GP Lens Designs
ICD 16.5 is a lens design created by Dr. John Mountford, Patrick Caroline, and Randy Kojima. Paragon recently licensed the product to offer the marketplace to their distributors for manufacture.NormalEyes 15.5 is a lens design created by Dr. Jerry Legerton and Dr. Bill Meyers for Paragon Vision. The nomenclature is the same as the Paragon CRT lens. (BC/RZD/LZA). This product is manufactured by ParagonBoth lens designs; vault the cornea and the limbus while resting on the sclera.incorporate the use of an tangent periphery to match the angle of the limbal/scleral junction.are manufactured from Paragon HDS100 material.
Thank you for yourattentionThank you for your continued support of Paragon products and if you have any questions, please see me after.23