KenTec Lidar
-
Upload
kent-larsen -
Category
Environment
-
view
145 -
download
0
Transcript of KenTec Lidar
KenTec Denmark ApS Rosenstien 12 DK-8800 Viborg, Denmark Tel. +45 20738196 www.kentec.dk
KenTec Denmark
LIDAR WIND MEASUREMENT
Our solution in remote sensing contain build-in Lidar with autonomous power supply allowing
unmanned automatic operation on remote locations.
The complete system is equipped with remote
communication allowing supervision of both the wind
data and the power supply. Through the WEB, the
system is full time online.
Built into the cargo trailer, the Lidar is well protected.
Further, inside the container is found the battery
bank, controllers and a diesel backup, should the solar
and wind generator fail to charge the batteries.
Thus, the environment inside the container offers
great comfort for both equipment and personnel
working on the unit.
KenTec Denmark ApS Rosenstien 12 DK-8800 Viborg, Denmark Tel. +45 20738196 www.kentec.dk
Inside the container, the diesel generator operates autonomous by the controller from Deep Sea
Electronics allowing both manual and
WEB based remote operation. The
controller monitors the conditions of the
battery bank and should the solar and
wind generator not be able to maintain
adequate voltage level, the diesel
generator will start up and charge the
batteries.
The diesel tank contain 75 litres of diesel
allowing long time autonomous
operation of the system. Below the diesel
elevation bench, a compartment can be
used for engine oil.
The four 6Volt GEL batteries, supplying
24VDC to the system, are built into an airtight isolated aluminium container, which also allow
room for tools, manuals and other equipment that need protection from humidity.
KenTec Denmark ApS Rosenstien 12 DK-8800 Viborg, Denmark Tel. +45 20738196 www.kentec.dk
When the diesel generator operates, the batteries are
charged and maintained by an intelligent charger by
up to 60 Amps.
Next to the charger an inverter, supply a 230VAC
socket for up to 1000W pure sine curve.
The battery bank voltage may
vary in voltage depending on the
charge level. However, the supply
for the Lidar is maintained fixed
at 24,5 VDC by a stable DC/DC
inverter.
The Lidar is imbedded into the container roof. The picture below presents the Lidar next to a
GPS antenna on which adjustable rod an IP Camera is attached. This camera can be used as
theft protection as it has a PIR sensor build in which register movement in front of the lenses
and takes a photo (or video) of what is in front of it. When a picture is taken, immediately it is
forwarded with an e-mail to the operator. The camera can also take a picture of the surface of
the Lidar so the operator can see if the sensor surface is free and uncovered and the wiper is
working properly.
Behind the Lidar, the fan box is
mounted. When the diesel generator
operates, the fan is engaged. The fan
box has its outlet pointing toward the Lidar in level with the Lidar’s surface, thus when
running, warm air is blown over the Lidar’s sensor plate keeping it free of ice, snow or leaves
etc.
Attached to the fan box the meteorological sensor that follow the Lidar is found.
KenTec Denmark ApS Rosenstien 12 DK-8800 Viborg, Denmark Tel. +45 20738196 www.kentec.dk
The Lidar is fixed to the container roof
allowing the personnel operation and
connection of Laptop computers etc.
comfortly at standing height.
Besides the Lidar the external sprinkler
tank is found. This contain 15 litres of
sprinkler fluid to maintain the level of the
internal reservoir.
Adjusting the Lidar:
The Lidar is adjusted to a fixed angle related to the trailer, so that levelling the trailer
correctly will same time level the Lidar correctly. The trailer is held in a backward angle
allowing water to run off the roof and interior.
Levelling the trailer is done by adjusting four legs in each corner of the trailer.
A spirit leveller inside the trailer box indicates when the correct level is reached.
KenTec Denmark ApS Rosenstien 12 DK-8800 Viborg, Denmark Tel. +45 20738196 www.kentec.dk
Overveiw.
GSM Antenna
IP Camera
Lidar meteorological
sensor
Lidar sensor
Solar panel
Wind generator
Fan box
Air intake
Diesel generator
exhaust pipe Adjustable legs for
container leveling.
KenTec Denmark ApS Rosenstien 12 DK-8800 Viborg, Denmark Tel. +45 20738196 www.kentec.dk
Remote control and supervision
Both the Lidar and the power supply can be supervised remotely via the Internet.
Below the SpiDAR CCU provides a detailed view of the measured data online.
KenTec Denmark ApS Rosenstien 12 DK-8800 Viborg, Denmark Tel. +45 20738196 www.kentec.dk
Vital informations like voltage on the battery bank, fuel level on the diesel tank, temperature
and if in operation, also the conditions of the diesel generator.
The diesel generator can be operated for Manual and Automatic operation.
Each analog instrument can present historical values on graphs or exported as ascii files for
Excel etc.
KenTec Denmark ApS Rosenstien 12 DK-8800 Viborg, Denmark Tel. +45 20738196 www.kentec.dk
An event list and alarm list is also presented remotely.
Besides the Lidar’s GPS, the DSE Webnet system is equipped with a GPS that present the
current location on a map. Thus, two redundant GPS systems presents the location of the
equipment.
KenTec Denmark ApS Rosenstien 12 DK-8800 Viborg, Denmark Tel. +45 20738196 www.kentec.dk
An APP for smart phones is available and enables supervision and operation of the power
system.