KE2 EvaporatorEfficiency Supermarket Retrofit Kit

2
© Copyright 2015 KE2 Therm Solutions, Inc., Washington, Missouri 63090 KE2 EvaporatorEfficiency Supermarket Retrofit Kit KE2 Evaporator Efficiency control makes a difference - The KE2 Evap is proven to reduce or eliminate icing issues, provides remote monitoring and control, and is third party verified as an energy saving controller*. Now, the KE2 Evap is available in the KE2 Evap Supermarket Retrofit kit, a complete package for upgrading walk-ins and refrigerated rooms to improve the operating en- vironment. In addition to the KE2 Evap controller, the kit includes a mounting box, wire harness, Ethernet adaptor and door switch. A.1.74 March 2015 AFTER: Using the KE2 Evaporator Efficiency control- ler, excessive frost build-up is eliminated through adaptive refrigeration control. The room cools more evenly, food quality is preserved and energy is saved. BEFORE: Refrigerated spaces can often experience a variety of issues related to the build-up of frost on evaporator coils, unit cooler cabi- nets, walk-in ceilings and stored product. * Energy savings were verified in testing performed by Ameren Missouri, Fisher Nickel, Cascade Energy, Avista Utilities and more. pn 21096 Eliminate Frost Buildup

Transcript of KE2 EvaporatorEfficiency Supermarket Retrofit Kit

Page 1: KE2 EvaporatorEfficiency Supermarket Retrofit Kit

© Copyright 2015 KE2 Therm Solutions, Inc., Washington, Missouri 63090

KE2 EvaporatorEfficiencySupermarket Retrofit Kit

KE2 Evaporator Efficiency control makes a difference - The KE2 Evap is proven to reduce or eliminate icing issues, provides remote monitoring and control, and is third party verified as an energy saving controller*.

Now, the KE2 Evap is available in the KE2 Evap Supermarket Retrofit kit, a complete package for upgrading walk-ins and refrigerated rooms to improve the operating en-vironment. In addition to the KE2 Evap controller, the kit includes a mounting box, wire harness, Ethernet adaptor and door switch.

A.1.74 March 2015

AFTER:Using the KE2 Evaporator Efficiency control-ler, excessive frost build-up is eliminated through adaptive refrigeration control. The room cools more evenly, food quality is preserved and energy is saved.

BEFORE:Refrigerated spaces can often experience a variety of issues related to the build-up of frost on evaporator coils, unit cooler cabi-nets, walk-in ceilings and stored product.

* Energy savings were verified in testing performed by Ameren Missouri, Fisher Nickel, Cascade Energy, Avista Utilities and more.

pn 21096

Eliminate Frost Buildup

Page 2: KE2 EvaporatorEfficiency Supermarket Retrofit Kit

© Copyright 2015 KE2 Therm Solutions, Inc., Washington, Missouri 63090 KE2 Therm Solutions 209 Lange Dr. . Washington, MO 63090

1-888-337-3358 . www.ke2therm.com

A.1.74 March 2015 Page 2

KE2 EvaporatorEfficiencySupermarket Retrofit Kit

KE2 Evaporator Efficiency Supermarket Retrofit Kit pn 21096

Contents:

A KE2 Evaporator Efficiency - pn 20178 includes KE2 Evap controller, mounting hardware, screw down terminals, voltage jumpers and air sensor mount

B Mounting Box - pn 20687 40 mil embossed aluminum

C KE2 Wire Harness pn 20736 9-wire, 10 ft. harness with appropriate gauge

wires and connections for controller

D Heavy Duty Door Switch - pn 20543 24” stainless steel armored cable, hermetically

sealed reed switch

E Ethernet Adaptor Kit - pn 20938

KE2 Evaporator Efficiency

eliminates icing issues

configurable to work with rack con-trollers or conventional systems

works with mechanical or electronic EPR’s

reduce/eliminate service calls from high temperature alarms as a result of frozen evaporator coils

achieve better room temperature control, and saves energy over rack controllers alone

works with ANY refrigerant or second-ary fluid system

troubleshoot using graphing / datalog of last 31 days of operational history

energy savings through reduction of defrosts and evap fan management

improved evaporator performance due to elimination of ice on the evaporator

A

KE2 Wire Harness

simplifies installation - color coded wires with connec-tors that correspond to the controller’s inputs

speeds installation - elimi-nates on site preparation of wires and wire labeling

reduces need to stock multiple colors and gauges of wires

C

Mounting Box

provides a stationary location to attach conduit

accommodates controller’s wiring and provides space for service loops

supports the controller when accessing the back of the controller

provides clean appearance to final installation

B

Door Switch

eliminates worry of door being left open

heavy duty for high traffic situations

D

Ethernet Adaptor Kit

Provides easy access to Ethernet port on backside of controller

No need to remove controller from mounting screws to ac-cess Ethernet on return visits.

E