Hazardous Areas Auditing – The Devil’s in the Details
Kayne HerrimanHazardous Areas & Type B Specialist, Bluefield AMS
![Page 2: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/2.jpg)
In a nut shell ….• Qualified Electrician • Instrumentation & Control Technician• Refrigeration & Air Con Mechanic• Hazardous areas units - for
Install/maintain, classification & design• Bachelor of Electrical / Electronic
Engineering – RPEQ• Type B Gas Qualified
![Page 3: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/3.jpg)
The compliance journey
![Page 4: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/4.jpg)
Audit Process
![Page 5: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/5.jpg)
Legislation Electrical Safety Act 2002 Electrical Safety Regulation 2013
Electrical Industry Act 2000
Electrical Safety (Registration & Licensing ) Regulation 2010
![Page 6: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/6.jpg)
Compliance
![Page 7: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/7.jpg)
Understanding how the system operates
A Physical Sample Collector was found to have classification as Zone 22 (Secondary grade of release) By AS/NZS 60079.10.2 Section 3.16 the definition of a secondary grade of release is:
… is not expected to occur in normal operation and, if it does occur, is likely to do so only infrequently and for short periods …
No markings and inside Zone 22
![Page 8: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/8.jpg)
Type B or Hazardous Areas where do you draw the line
![Page 9: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/9.jpg)
Not taking peoples word for itWas assured by the site engineer the area classification was
IIIB Non-Conductive dust
After reading the classification and consulting the simtars reports it was found that
Apart from being the incorrect dust group if the engineer had been providing this information to other hazardous areas installers and they have not challenged it then potentially the equipment they are installing is non-complaint.
![Page 10: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/10.jpg)
Who reads certificates anyway?
AUS Ex 875X.pdf
IECEx KEM 09.0068X + Annex.pdf
IECEx_TUR_11.0003X_0.pdf
IECEx_TUR_11.0003X_1.pdf
![Page 11: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/11.jpg)
Who reads certificates anyway?
IECEx_PTB_13.0003_1
IECEx_SIM_09.0001X_1
05.0035U Annexe Iss1.pdf
IECE.pdf
![Page 12: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/12.jpg)
Workmanship
![Page 13: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/13.jpg)
Environment
![Page 14: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/14.jpg)
The important of getting the basics right
Vendor recommendations 16 Amps Circuit Protection
![Page 15: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/15.jpg)
Cant Audit what you do see
![Page 16: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/16.jpg)
Right people for the right task
![Page 17: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/17.jpg)
Don’t just sign it off….
![Page 18: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/18.jpg)
The role of an Accredited Hazardous Areas Auditor
As previously mentioned, in Queensland a person must not connect or reconnect an electrical installation located in a Hazardous Area, to a source of electricity after electrical installation work has been performed on the electrical installation unless—
a)the electrical work has been inspected by an accredited auditor; and
b)the accredited auditor has confirmed that the electrical installation, to the extent it is affected by the electrical work, has been tested to ensure it is electrically safe and complies with the requirements of the wiring rules and any other standard applying under this regulation to the electrical installation.
![Page 19: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/19.jpg)
ConclusionTo say a piece of equipment is compliant is to say that:
•The installation has been correctly classified•The equipment selection is correct•The equipment has been installed as per the certificate of conformity and/or manufactures specifications•Accessories and terminations comply, have been done correctly and, where relevant to a correct torque •Equipment has been electrically tested and deemed safe•The inspector is trained, competent and authorised
The role of an Accredited Hazardous Areas Auditor
a)the electrical work has been inspected by an accredited auditor; andb)the accredited auditor has confirmed that the electrical installation, to the extent
![Page 20: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/20.jpg)
Teaser 1 xde_ptb.ptb13.0003.1.pdf
![Page 21: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/21.jpg)
Teaser 2 BKI08 ATEX 019.pdf
![Page 22: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/22.jpg)
Teaser 3 IECEx SIR 12.0103X Issue 2.pdf
IECEx SIR 12.0103X Annexe Iss 2.pdf Voltage and
Equipment Standard Misalignment PaperV.pdf230_240 Voltage Australia.PNG
![Page 23: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/23.jpg)
Teaser 4
Vendor Response: …yes we assemble it all here. The
electronics is an amp for the sensor. It's not certified I don't think, which is why it is put in the junction boxes…
AUSEx 03.3892
![Page 24: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/24.jpg)
Teaser 5 IECEx BAS 10,0051x
Baseefa_10ATEX0092X
Dialight Catalog
![Page 25: Kayne Herriman PowerPoint Template - Hazardous Areas Conference V1](https://reader036.fdocuments.in/reader036/viewer/2022082206/5899fbad1a28abc5778b6329/html5/thumbnails/25.jpg)
Questions
Kayne Herriman Hazardous Areas & Type B SpecialistQLD Accredited Hazardous Areas Auditor 02/ 0193Type B Gas Qualified
Mob +61 403 568 740Email [email protected]