karta_ 2 025-00

4
TECHNICAL DATA LSA-PLUS ® Edge Connector Description The Edge Connector portfolio has been designed specifically for use in telecommunication circuits wherever high density connectivity is required between a Printed Circuit Board and cable wires. The Edge Connector (EC) plugs directly onto a Printed Circuit Board (PCB) to connect a cable harness or individual wires. The cable wires are connected using the tried and tested LSA-PLUS ® contacts. Wire guide loops ensure orderly routing of the wires, making cable management simple and more effective. An overview of the variety of sizes, pair counts and connection types is given in the table below. Features and Benefits • Highest contact quality • Space saving • Available in a variety of sizes for different pair counts • Compatible with LSA-PLUS ® insertion tool • Fast Termination • Over voltage protection option for 20 pole • Accessories available Technical Assistance Europe & Middle East +32 2 712 6542 [email protected] www.adckrone.com EC Type Pair counts / add contact Connection Disconnection Required PCB thickness EC 25 24 / 1 1.2mm ± 0.2mm EC 20 20 / 0 - 1.5mm ± 0.13mm EC 17 16 / 1 1.2mm ± 0.2mm EC 17 16 / 1 - 1.5mm ± 0.13mm EC 14 14 / 0 - 1.5mm ± 0.13mm Installation Whether in industrial electronics, regulation or control technology, telemetry or input circuits of PBX systems, the LSA-PLUS ® Edge Connector can be effectively used in all applications where cable wires with a conductor diameter of 0.4mm to 0.6 mm are directly connected to printed circuit boards.

Transcript of karta_ 2 025-00

  • TEC

    HN

    ICA

    L D

    ATA

    LSA-PLUS

    Edge Connector

    Description

    The Edge Connector portfolio has been designed specifically for use in telecommunication circuits wherever high density connectivity is required between a Printed Circuit Board and cable wires. The Edge Connector (EC) plugs directly onto a Printed Circuit Board (PCB) to connect a cable harness or individual wires. The cable wires are connected using the tried and tested LSA-PLUS contacts. Wire guide loops ensure orderly routing of the wires, making cable management simple and more effective. An overview of the variety of sizes, pair counts and connection types is given in the table below.

    Features and Benefits

    Highest contact quality

    Space saving

    Available in a variety of sizes for different pair counts

    Compatible with LSA-PLUS insertion tool

    Fast Termination

    Over voltage protection option for 20 pole

    Accessories available

    Technical AssistanceEurope & Middle East +32 2 712 6542 [email protected]

    www.adckrone.com

    EC Type Pair counts / add contact Connection Disconnection Required PCB thickness

    EC 25 24 / 1 1.2mm 0.2mmEC 20 20 / 0 - 1.5mm 0.13mmEC 17 16 / 1 1.2mm 0.2mmEC 17 16 / 1 - 1.5mm 0.13mmEC 14 14 / 0 - 1.5mm 0.13mm

    Installation

    Whether in industrial electronics, regulation or control technology, telemetry or input circuits of PBX systems, the LSA-PLUS Edge Connector can be effectively used in all applications where cable wires with a conductor diameter of 0.4mm to 0.6 mm are directly connected to printed circuit boards.

  • 07

    /0

    7

    30

    02

    10

    BE

    LS

    A-P

    LUS

    E

    dg

    e C

    on

    nec

    tor

    w w w . a d c k r o n e . c o m + 4 9 - 3 0 - 8 4 5 3 - 1 8 1 8 + 4 9 - 3 0 - 8 4 5 3 - 1 7 0 3

    Product SpecificationsELECTRICAL CHARACTERISTICS

    Insulation resistance >5x104M @ 500V Contact resistance LSA-PLUS contact 2.5m PCB contact 5m Disconnection contact 2.5m Operating circuits TNV1 up to TNV3, RFC up to 320V

    Electrical strength 2kVeff

    Surge voltage strength (1.2/50s) 3.6kV

    Current-carrying capacity 1.3A / each contact (max. rated current in telecommunication networks)

    Impulse current (8/20 s) LSA-PLUS Contact 5kA PCB contact 5kA Disconnection contact 0.5kA

    TEMPERATURE CHARACTERISTICS

    Operating temperature -20C to +60C

    Storage temperature -40C to +70C

    ENVIRONMENTAL CHARACTERISTICS

    Relative humidity 95%; no water condensation, no ice

    Sinusoidal vibration In accordance with

    IEC 60068-2-6 IEC 60068-2-1 (cold), IEC 60068-2-2 (dry heat) IEC 60068-2-78 (damp heat, steady state)

    MECHANICAL CHARACTERISTICS

    Single solid conductor 0.4 0.63mm (AWG26AWG22) or

    Tin coated copper strands 7x0.15 ... 0.25mm (AWG26AWG22)

    Wire outer diameter 0.7 1.1mm with PE or PVC solid insulation

    Number of reterminations 50 times

    Contact surface LSA-PLUS contact Cu/Sn Disconnection contact Au

    Insertion force per contact approx. 5.5N (depends on PCB tolerance)

    Withdrawal force per contact approx. 2.5N (depends on PCB tolerance)

    RoHS In accordance with European Directive 2002/96/EG

    Plastics PC/ABS

    Plastics flammability class: UL94V-0

    LSA-PLUSEdge Connector

  • 07

    /0

    7

    30

    02

    10

    BE

    LS

    A-P

    LUS

    E

    dg

    e C

    on

    nec

    tor

    3w w w . a d c k r o n e . c o m + 4 9 - 3 0 - 8 4 5 3 - 1 8 1 8 + 4 9 - 3 0 - 8 4 5 3 - 1 7 0 3

    LSA-PLUSEdge Connector

    EC Type A [mm] B [mm] Remarks

    EC 25 76.2 0.1 72.0 0.1

    Strip lines on both sides of the PCBEC 20 61.2 0.1 57.0 0.1

    EC 17 52.2 0.1 48.0 0.1

    EC 14 43,2 0,1 39,0 0,1

    Printed circuit board characteristics

    Thickness 1.2mm 0.12mm 1.5mm 0.13mm

    Contact area tin-plated

    Coating thickness of strip lines 5m (minimum)

    Strip lines on both sides of the PCB

    Frequency of connection of EC onto PCB 5 times

    Dimensions, in mm

    Dimensions, in mm

  • TEC

    HN

    ICA

    L D

    ATA

    Web Site: www.adckrone.com

    EMEA Office: ADC GmbH, Beeskowdamm, 3-11, 14167 Berlin, Germany Phone: +49 30 8453-1818 Fax: +49 30 8453-1703. For a listing of all ADC KRONEs global sales office locations, please refer to our web site.

    UK Office: ADC Communications (UK) Ltd., Runnings Road, Kingsditch Trading Estate, Cheltenham, Gloucestershire GL51 9NQ, United Kingdom Phone: +44 (0) 1242 264 400 Fax: +44 (0) 1242 264 488 [email protected]

    Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ADC KRONE reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting ADC GmbH headquarters in Berlin. ADC Telecommunications, Inc. views its patent portfolio as an important corporate asset and vigorously enforces its patents.

    Part Number 300210BE Jul 07 Original 2007 ADC Telecommunications Inc. All Rights Reserved

    O r d e r i n g I n f o r m a t i o n

    Description Catalogue Number

    EC 25 with connection contact, for use onto 1.2 mm PCB 6623 2 022-xx

    EC 25 with disconnection contact, for use onto 1.2 mm PCB 6623 2 027-xx

    EC 20 with connection contact, for use onto 1.5 mm PCB, enhanced LSA-6623 2 040-xx

    EC 17 with connection contact, for use onto 1.2 mm PCB 6623 2 020-xx

    EC 17 with disconnection contact, for use onto 1.2 mm PCB 6623 2 026-xx

    EC 17 with connection contact, for use onto 1.5 mm PCB 6623 2 028-xx

    EC 17 with connection contact, for use onto 1.5 mm PCB, enhanced LSA-6623 2 041-00

    EC 14 with connection contact, for use onto 1.5 mm PCB 6623 2 036-10

    Accessories

    Accessories, Test cord, 2-pole 6623 2 023-00

    Accessories, Test cord, 4-pole 1) 6623 2 030-00

    Accessories, Test cord, 2-pole, with open leads 6623 2 033-00

    Accessories, Patch cord, 2-pole 6623 2 024-00

    Accessories, Disconnection plug 1) 6623 3 050-00

    Accessories, Changeover adapter, 2-pole, 2m; EC to open leads 2) LSA-6623 2 052-02

    Accessories, Changeover adapter, 2-pole, 2m; EC to Series2 2) LSA-6623 2 017-02

    Accessories, Changeover adapter, 2-pole, 2m; EC to SeriesNT 2) LSA-6623 2 018-02

    Accessories, Test cord, 2-pole; 200mm 2) LSA-6623 2 054-00

    Over voltage protection magazine, 10 pairs PRO-6623 2 044-xx

    1) Only for disconnection modules like 6623 2 027-xx 6623 2 026-xx

    2) Only for connection modules like LSA-6623 2 040-00; LSA-6623 2 040-50; LSA-6623 2 041-00