Copyright© JSE Limited 2013 www.jse.co.za 1 JSE Limited JSE Colocation These slides may not be used in any manner without prior written permission from the JSE Compiled: March 2013. Disclaimer: This document describes a possible product development by the JSE Limited (“JSE”) which is subject to demand. Information on the services, systems, products, or materials presented herein is provided for informational purposes only. The JSE makes no commitments, representations or warranties herein, either expressed or implied, regarding the accuracy or completeness of this information. In no event shall the JSE be liable for any injury, loss or damage resulting from use of or reliance upon the information and any reliance you place on such information is therefore strictly at your own risk. The JSE reserves the right to make changes or updates to the possible product development at any time without notice. Contractual arrangements will be entered into with interested parties in relation to the possible product development. For further information, please contact the JSE. © 2013 JSE Limited. All rights reserved.

Transcript of JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3...

Page 1: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

Copyright© JSE Limited 2013

www.jse.co.za

1

JSE Limited

JSE ColocationThese slides may not beused in any mannerwithout prior writtenpermission from the JSE

Compiled: March 2013.Disclaimer: This document describes apossible product development by the JSELimited (“JSE”) which is subject to demand.Information on the services, systems,products, or materials presented herein isprovided for informational purposes only. TheJSE makes no commitments, representationsor warranties herein, either expressed orimplied, regarding the accuracy orcompleteness of this information. In no eventshall the JSE be liable for any injury, loss ordamage resulting from use of or reliance uponthe information and any reliance you place onsuch information is therefore strictly at yourown risk. The JSE reserves the rightto make changes or updates to the possibleproduct development at any time withoutnotice.Contractual arrangements will be entered intowith interested parties in relation to thepossible product development. For furtherinformation, please contact the JSE.© 2013 JSE Limited. All rights reserved.

Page 2: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

Copyright© JSE Limited 2013

www.jse.co.za

2

JSE Colocation OfferingLeanne Parsons

Page 3: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

3

Copyright© JSE Limited 2013

www.jse.co.za

The JSE Colocation Ecosystem

Page 4: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

4

Copyright© JSE Limited 2013

www.jse.co.za

Colocation Principles

MARKETSJSE colocation will provide clients access 

to all JSE markets, although the implementations will be phased.

TRANSPARENCYThe JSE will measure, monitor and publish colocation service quality parameters on a 

central portal.

PRICINGThe pricing of all colocation offerings will 

be the same for all client types.

LIMITED CAPACITYRacks will be allocated on a first come first 

served basis within a limited capacity constraint.

CLIENTSAll JSE client types will be permitted to collocate:

JSE members + their Clients, JSE information subscribers + their Clients, JSE SIPs + their Clients, 

MSPS and NSPs.

SERVICE EQUALITYThe JSE colocation environment will be designed to provide equal performance to all racks from the Trading Systems regardless of its 

location in the facility.

Page 5: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

5

Copyright© JSE Limited 2013

www.jse.co.za

Key Data-Centre Characteristics

Aligned toTIER III Standards(Availability)

Aligned toTIER III Standards(Availability)

Network Service Provider (NSP) agnostic

CARRIER HOTEL

Network Service Provider (NSP) agnostic

CARRIER HOTEL

All Managed Service Providers (MSP) 

permitted

All Managed Service Providers (MSP) 

permitted

24/7Remote Hands

Service

24/7Remote Hands

Service

24/5 – 8/2Access to 

Data Centre

24/5 – 8/2Access to 

Data Centre

Monitoring data published onlineMonitoring data published online

Page 6: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

6

Copyright© JSE Limited 2013

www.jse.co.za

Key Benefits

Fastest trading access irrespective to client location or client type

Fastest market data access 

LATENCY ADVANTAGE

Enabler of low latency trading strategies through High speed trading access Potential execution probability 

improvement Enhanced response to market movement

NEW TRADING STRATEGIES

Reduce bandwidth cost by replacing trade and data flow by configuration flow

COST SAVINGS

Reduced dependence on NSP performance Resilient infrastructure throughout the 

environment

RISK MITIGATION

Page 7: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

7

Copyright© JSE Limited 2013

www.jse.co.za

Current Connectivity

Page 8: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

8

Copyright© JSE Limited 2013

www.jse.co.za

Colocation Concept

Page 9: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

9

Copyright© JSE Limited 2013

www.jse.co.za

Latency Measurement

Latency* measured from gateway‐to‐gateway is consistent. Latency is measured specifically for the Equity Market and may vary across clients. Latency excludes trading engine turn‐around‐time. Latency is based on the fastest quoted latency value by network service providers in each region in South Africa.

Page 10: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

10

Copyright© JSE Limited 2013

www.jse.co.za

Indicative Latency Gain – Colocation vs Access Network

Colocatio

n Client

JSE Co

locatio

n Network

Trad

ing Gatew

ay

Trad

ing En

gine

Trad

ing / Market 

Data Gatew

ay

JSE Co

locatio

n Network

Colocatio

n Client

Access Network Clients ~2550 µs to 210 150 µsCurrent ~2 785 µs to 210 385 µs

Colocation Clients~250 µs

MIT Trading Engine ~150 µs Current ~385 µsJS

E Ac

cess

Network

JSE Ac

cess

Network

Local Client Network Latency Gain via Colocation : at least 24 x faster!

International Client Network Latency Gain via Colocation : 2 100 x faster!

µs = micro seconds

Page 11: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

11

Copyright© JSE Limited 2013

www.jse.co.za

Colocation Products and Services

Trading Engine Connectivity: 10 Gbps fiber X 6

PRIMARY PRODUCT: FULL RACK

Remote Management Connectivity: 1 Gbps fiber X 2 

Power per Rack:    3.3 kVA

6  X  fibres to JSE infrastructure Equity Market 

1 X trading connectivity  1 X redundant trading connectivity  2 X market data connectivity (A and B Feed)

All Other Markets  1 X trading & market data connectivity 1 X redundant trading & market data 

connectivity 

Power allocation Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month

3.3 kVA X 8 hours X 5 days 3.3 kVA X 50% X 16 hours X 5 days 3.3 kVA X 50% X 24 hours X 2 days

Additional power consumption will be chargeable and consistent power usage in excess of the threshold will result in the purchase of an additional rack

2 x Fibres to JSE devices in access network 1 X  client’s management connectivity 1 X  redundant client’s management connectivity

Page 12: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

12

Copyright© JSE Limited 2013

www.jse.co.za

Colocation Products and Services (cont.)

Cross Connect: JSE Enabled  Sub‐letting: JSE Enabled

SECONDARY PRODUCTS

The following types will be allowed Member to same member rack Member rack to client rack Member rack to SIP rack Client rack to SIP rack Once‐off installation fee of R3 500  Monthly maintenance fee of R 500 

The following subletting options will be permitted: Member to Member Client SIP to Member Each has to be registered with the JSE No additional charges for sub‐letting

Time Sync Service:   Subscription Based

No additional cost for initial take up of first 35 racks Clients will need to procure compatible hardware

Page 13: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

13

Copyright© JSE Limited 2013

www.jse.co.za

Colocation Products and Services (cont.)

Monitoring: LATENCY  Support: REMOTE HANDS

ASSOCIATED SERVICES

Once‐Off: ON‐BOARDING 

Limited remote hands support will be available Available to all participants 24/7 No additional fee up to a specified limit Further support through MSPs/NSPs

JSE Infrastructure Latency monitoring will be performed During trading hours Published on a central portal No additional fee 24/7 environment monitoring will also be 

performed

On‐boarding will comprise of Requirement gathering and design advice Test facilitation  Rack and Stack Once‐off fixed fee will be charged Future changes will follow a change request 

process and charged on a time & material basis

Page 14: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

14

Copyright© JSE Limited 2013

www.jse.co.za

Data Centre Security

Security personnel available 24/7 Camera surveillance

PHYSICAL

Strict access policy across booking, identification, access processes and procedures All visitors will be escorted by JSE staff Bio‐metric access to racks Multi‐layered network security

ACCESS

Environmental monitoring  Central monitoring system with 24/7 dedicated monitoring personnel

MONITORING

Page 15: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

15

Copyright© JSE Limited 2013

www.jse.co.za

Colocation Price

R 51 000

3.3 kVA Power Access to all JSE markets 2 X Equity Trading Connectivity* 2 X Equity Market Data Connectivity 

(A & B Feed) 2 X Derivatives Trading & Market 

Data Connectivity* 2 X Remote Management 

Connectivity* 24/7 remote hands support Latency monitoring service Time sync service

*Including Trading Redundancy

3.3 kVA Power Access to all JSE markets 2 X Equity Trading Connectivity* 2 X Equity Market Data Connectivity 

(A & B Feed) 2 X Derivatives Trading & Market 

Data Connectivity* 2 X Remote Management 

Connectivity* 24/7 remote hands support Latency monitoring service Time sync service

*Including Trading Redundancy

Once‐off on‐boarding charges Additional trading connectivity Additional market data connectivity Additional client connectivity Cross‐connect fees

Once‐off on‐boarding charges Additional trading connectivity Additional market data connectivity Additional client connectivity Cross‐connect fees

INCLUSIONS EXCLUSIONS

Page 16: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

16

Copyright© JSE Limited 2013

www.jse.co.za

Colocation Indicative Timelines

Page 17: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

17

Copyright© JSE Limited 2013

www.jse.co.za

JSE Colocation Offering – Contact Details

For further information relating to the JSE Co-Location Offering, pleasesend an email to [email protected]

Documentation link• http://www.jse.co.za/Documents-and-Presentations/JseColocation/Co-location.aspx

Page 18: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5

18

Copyright© JSE Limited 2013

www.jse.co.za

Copyright© JSE Limited 2011

Questions ?

Refer queries to:

[email protected]

+27 11 520 7777

Page 19: JSE Colocation used in any manner without prior written … · 2016-07-06 · Standard minimum 3.3 kVA per rack No additional charge till 1344 kWh per month 3.3 kVA X 8 hours X 5