JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

33
Waterstops for Chemical, Industrial, & Environmental Applications ® W aterstops play a critical role in the integrity of concrete structures. They provide a fluid-tight diaphragm when embedded in, and running through concrete joints. Earth Shield® Thermoplastic Vul- canizate Waterstop (TPV), by JP Specialties, Inc., greatly expands the scope of conventional water - stop by offering unmatched chemical resistance to a broad spectrum of aggressive chemicals, solvents, and hot petroleum oils. Manufactured NSF certified, EPA-compliant waterstop profiles are available for new construction and retrofit, as well as the tools and accessories for proper field installation. JP Specialties, Inc. is the leading manufacturer of chemical resistant waterstop and related concrete accessories. Our NSF 61 certified Earth Shield® line of chemical resistant waterstop is used throughout the world by major engineering firms and project owners for primary and secondary containment ap- plications, as well as industrial wastewater treatment and ozone contactor structures. We invented and hold the patent on the technology used to mechani- cally weld thermoplastic waterstops. Services offered include free blueprint take-off and shop drawings, on-site welding certification, and individual corrosion resistance certification for the project owner. J P SPECIALTIES, INC. J P SPECIALTIES, INC. Earth Shield ® Chemical Resistant Waterstop Phone: 800-821-3859; 951-763-7077 Fax: 951-763-7074 www.earthshield.com Earth Shield ® JP636 TPV Ribbed Centerbulb (6” width) is the industry standard, utilized on most jobs for its proven fluid-sealing properties. See page 4 for more info Earth Shield ® Retrofit Column and Pipe Fitting (part number JP320LC1.XX* [*XX is diameter in inches]) is manufactured with a flexible, chemical-resistant polymer and includes all stain- less steel anchoring hardware. See page 14 for more info Section 03150 • MasterFormat™ 03 15 13 All ribbed Earth Shield® Waterstop profiles are available with factory installed brass eyelets. The eyelets provide for a convenient and durable tie-off point for wire tying the waterstop to the steel reinforcement prior to the concrete pour. www.facebook.com/waterstop www.facebook.com/waterstop www.GreenSpec.com www.GreenSpec.com

Transcript of JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Page 1: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Waterstops for Chemical, Industrial, & Environmental Applications

®

Waterstops play a critical role in the integrity of concrete structures. They provide a fluid-tight

diaphragm when embedded in, and running through concrete joints. Earth Shield® Thermoplastic Vul-canizate Waterstop (TPV), by JP Specialties, Inc., greatly expands the scope of conventional water-stop by offering unmatched chemical resistance to a broad spectrum of aggressive chemicals, solvents, and hot petroleum oils. Manufactured NSF certified, EPA-compliant waterstop profiles are available for new construction and retrofit, as well as the tools and accessories for proper field installation.

JP Specialties, Inc. is the leading manufacturer of chemical resistant waterstop and related concrete accessories. Our NSF 61 certified Earth Shield® line of chemical resistant waterstop is used throughout the world by major engineering firms and project owners for primary and secondary containment ap-plications, as well as industrial wastewater treatment and ozone contactor structures. We invented and hold the patent on the technology used to mechani-cally weld thermoplastic waterstops.

Services offered include free blueprint take-off and shop drawings, on-site welding certification, and individual corrosion resistance certification for the project owner.

J P SPECIALTIES, INC.

J P SPECIALTIE

S, INC.

Earth Shield® Chemical Resistant WaterstopPhone: 800-821-3859; 951-763-7077

Fax: 951-763-7074

www.earthshield.com

Earth Shield® JP636 TPV Ribbed Centerbulb (6” width) is the industry standard, utilized on most jobs for its proven fluid-sealing properties.

See page 4 for more info

Earth Shield® Retrofit Column and Pipe Fitting (part number JP320LC1.XX* [*XX is diameter in inches]) is manufactured with a flexible, chemical-resistant polymer and includes all stain-less steel anchoring hardware.

See page 14 for more info

Section 03150 • MasterFormat™ 03 15 13

All ribbed Earth Shield® Waterstop profiles are available with factory installed brass eyelets. The eyelets provide for a convenient and durable tie-off point for wire tying the waterstop to the steel reinforcement prior to the concrete pour.

www.facebook.com/waterstop

www.facebook.com/waterstop

www.GreenSpec.comwww.GreenSpec.com

Page 2: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Earth Shield® Thermoplastic Vulcani-zate (TPV / TPER) Waterstop Basic UseEarth Shield® Thermoplastic Vulcanizate Water-stop is used as a fluid-tight diaphragm, embed-ded in concrete, across and along the joint, for primary and secondary containment structures. Earth Shield® Chemical Resistant Waterstops

are resistant to a wide range of oils, solvents, and aggressive chemi-cals. Alcohol, ketones, glycols, esters, and aqueous solutions of acids, salts, and bases have little effect on Earth Shield® Thermo-plastic Vulcanizate Waterstop.

Unlike polyvinyl chloride (PVC) wa-terstop, Earth Shield® waterstop contains no plasticizer, stabilizer, or filler to leech out when exposed to chemicals, fuels, and aggres-sive industrial fluids. Also, unlike PVC waterstop, Earth Shield® can withstand prolonged exposure to

high and low temperatures (-78°F to 275°F long term) without detrimental effect.

Earth Shield® TPV Waterstop is NSF Standard 61 Certified for use in drinking water and is made of a recyclable polymer, so it’s good for health and the environment.http://www.earthshield.com/earth_shield_waterstop/waterstop_tpv/waterstop_tpv.html

The superior chemical resistance of Earth Shield® Thermoplastic Vulcanizate Waterstop is enhanced by the use of a ribbed centerbulb con-figuration, which is available in a 4, 6, and 9-inch width. This provides for greater mechanical bonding with the concrete and a barrier against migration of liquid flow around the waterstop. The ribbed centerbulb style also allows for joint movement and may be used in above or below grade applications. Additional shapes are avail-able for retrofit, extreme expansion, stainless steel and base seal applications.

Different varieties and grades of thermoplastic elastomers (TPE) are commercially available. On the low-end there is thermoplastic polyole-fin (TPO), which has a rubber phase that is not

cross-linked. On the high-end there is thermo-plastic vulcanizate (TPV)... Earth Shield® has chosen a fully cross-linked TPV as our standard elastomer compound, which provides superior mechanical properties, retention, and chemical resistance. In fact, when compared side-by-side, no competitive product is even close to achiev-ing the physical properties of Earth Shield®.

Typical Applications• Primary and secondary containment• Waste water treatment plants• Refineries• Ozone contactor structures• Mining facilities• Fueling areas• Chemical factories• Manure pits

Earth Shield® Advantages• Outstanding fluid resistance to a wide

range of aqueous-based fluids, oils, and hydrocarbons

• Excellent retention of physical properties at elevated temperatures

• Superior ozone and weather resistance

InstallationInstall Earth Shield® TPV Waterstop in all con-crete joints. Waterstop should be centered in, and run the extent of the joint. All changes of directions should be prefabricated (see Shop Made Fittings), leaving only butt-welding for the field. If installing in an expansion joint, keep center bulb unembedded to allow it to accom-modate movement as designed. Use optional factory installed brass eyelets (or #3 hog rings) and tie wire to secure waterstop to reinforcing steel to avoid displacement during the concrete pour. Splice straight lengths of waterstop, and Shop Made Fittings to straight lengths, with an ST-10® In Line Waterstop Splicer with the iron temperature set to 410°F to 430°F.More detailed installation instructions can be found in our Standard 3-part Specifications.

Page 2

Page 3: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Technical AssistanceQualified technical assistance is available during any phase of your construction project.

SpecificationsStandard 3-part Specifications are available at our website in Microsoft® Word and Adobe® PDF format, and upon request in printed and a variety of com-puter word processor formats. Call our Technical Sales Staff for additional help with your specification. http://www.earthshield.com/earth_shield_waterstop/waterstop_tpv/waterstop_tpv.html

Suggested Proprietary Short Form Guide Specification Section 03150(Master Format 2004 — 03 15 13)TPV Chemical Resistant Waterstop Waterstop indicated in drawings and specifica-tions for contraction (control), expansion and construction joints shall be Earth Shield® TPV Chemical Resistant Waterstop Part No. #### [Designer insert appropriate part number here] as manufactured by JP Specialties, Inc.; Murrieta, CA 92562; Phone 951-763-70771. Thermoplastic Vulcanizate (TPV) Waterstop shall con-

form to EPA Title 40 CFR Section 265.193. The suit-ability of the waterstop for a specific application should be determined by specific testing for that particular requirement per ASTM D471. Project-specific certifica-tion to be provided by the manufacturer.

2. Thermoplastic Vulcanizate (TPV) Waterstop shall be in-dependently certified for use in potable water per NSF/ANSI Standard 61. Third-party certified documentation to be provided by the manufacturer.

3. No equals or substitutions allowed.

Property Test Method Required ResultsSpecific Gravity

ASTM D792 .96

Shore A Hardness(5 sec.)

ASTM D2240 90±3 at 25°C (77°F)

Tensile Strength

ASTM D412 2,300 psi

UltimateElongation

ASTM D412 530%

100% Modu-lus

ASTM D746 1,000 psi

Tear Strength ASTM D624 278 pli at 25°C (77°F)Compression Set

ASTM D395 29% at 25°C (77°F)

Brittle Point ASTM D746 -61°C (-78°F)DrinkingWater Safe

NSF/ANSI 61 Waterstop certified by NSF for use in potable water

OzoneResistance

ASTM D1171 Passed, no cracking at 500 pphm

ChemicalResistance

ASTM D471 Meet or exceed spe-cific testing standards for contained fluids as required by Owner and certified by Manufac-turer

GreenCertification

GreenSpec Approved

Page 3

The Primary Choice for Secondary Containment®

Page 4: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Ribbed Centerbulbfor Moving and Non-Moving Joints

Ribbed centerbulb is the most versatile type of waterstop available. The centerbulb

accommodates lateral, transverse, and shear movement. Ribbed centerbulb can be used in expansion, construction, and control joints.

Ribbed centerbulb waterstops provide superior anchoring abilities and a long fluid-flow path be-cause of the multiple ribs on the exterior flanges. Under stress, the multiple ribs will distort less than a dumbbell type waterstop. This is because the stress is first applied to the inward-most anchoring rib, and decreases to the subsequent ribs.

The centerbulb allows for joint movement be-yond the ultimate elongation of the material (530%), without causing distortion to anchoring ribs. All of our ribbed centerbulb waterstops are manufactured with a 9/16” outer diameter cen-terbulb, which is the largest in the industry. This centerbulb, coupled with the outstanding me-chanical properties of our proprietary TPV elas-tomer (ultimate elongation, tensile strength, etc.), provides for unsurpassed joint movement and sealing abilities.

Like all our thermoplastic vulcanizate waterstops, ribbed centerbulb can be heat-welded using a standard waterstop splicing iron. This allows for easy field fabrications, and allows the waterstop to function as a continuous, homogeneous, fluid-tight diaphragm. Waterstop change of directions (fittings) can be purchased along with straight roll stock, and custom, fit-to-print waterstop mod-ules are produced to order.

Page 4

Page 5: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

7/16"[11.11]

3/16"[4.76]

1/4"[6.35]

1/4"[6.35]

Ø 9/16"[Ø 14.29]

4"[101.6]

6"[152.4]

7/16"[11.11]

3/16"[4.76]

1/4"[6.35]

1/4"[6.35]

Ø 9/16"[Ø 14.29]

Ø 9/16"[Ø 14.29]

1/4"[6.33]

1/4"[6.35]

3/16"[4.76]

9"[228.6]

7/16"[11.11]

Standard Fabrications

JP436 (with eyelets: EYJP436)4” Ribbed Centerbulb Waterstop75 ft Head of H20

JP636 (with eyelets: EYJP636)6” Ribbed Centerbulb Waterstop125 ft Head of H20

JP936 (with eyelets: EYJP936)9” Ribbed Centerbulb Waterstop175 ft Head of H20

JP436L1 Flat EllJP636L1 Flat EllJP936L1 Flat Ell

JP436T1 Flat TeeJP636T1 Flat TeeJP936T1 Flat Tee

JP436X1 Flat CrossJP636X1 Flat CrossJP936X1 Flat Cross

JP436L2 Vert EllJP636L2 Vert EllJP936L2 Vert Ell

JP436T2 Vert TeeJP636T2 Vert TeeJP936T2 Vert Tee

JP436X2 Vert CrossJP636X2 Vert CrossJP936X2 Vert Cross

Page 5

Page 6: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Retrofit Waterstop Systemsfor New to Existing Concrete Joints

Retrofit waterstop is designed to provide a fluid-tight seal between existing and new

concrete construction, without resorting to the la-bor-intensive and structurally destructive saw-cut-and-grout method. It is ideal for constructing a new containment curb or wall to an existing slab, or joining a new slab to an existing wall. Special profile fabrications are available for columns and pipe penetrations.

All of our retrofit waterstops are sold as a system, and include all the necessary stainless steel bars and bolts. We also offer a high-quality chemi-cal resistant novolac epoxy — VEN 1000. Earth Shield® retrofit waterstops are manufactured with our proprietary thermoplastic vulcanizate com-pound, which provides for unsurpassed chemical resistance.

Like all our thermoplastic vulcanizate waterstops, Earth Shield® retrofit can be heat-welded using a

standard waterstop splicing iron. This allows for easy field fabrications, and allows the waterstop to function as a continuous, homogeneous, fluid-tight diaphragm. Waterstop change of directions can be purchased along with straight roll stock, and custom, fit-to-print waterstop modules are produced to order. Prefabricated ells, tees, tank pads, column fittings, and many others are in stock and ready to ship.

R 9/32"[R 7.14]

7/8"[22.23]

9/16"[14.29]

3 9/32"[83.34]

3/16"[4.76]

3 11/16"[93.66]

3/16"[4.76]

7/16"[11.11]

1/4"[6.35]

3"[76.2]

3"[76.2]

7/16"[11.11]

1/4"[6.35]

3/16"[4.76]

JP320L (with eyelets: EYJP320L)Retrofit Waterstop System(Includes all batten bars and anchors)125 ft Head of H20

JP336L (with eyelets: EYJP336L)Retrofit Waterstop System(Includes all batten bars and anchors)125 ft Head of H20

Page 6

Page 7: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

7/16"[11.11]

3"[76.2]

3 13/64"[81.35]

3 43/64"[93.25]

3/16"[4.76]

1/4"[6.35]

1/4"[6.35]

1/2"[12.7]

4 1/2"[114.3]

Ø 9/16"[Ø 14.29]

45/64"[17.86]

1/2"[12.7]

3"[76.2]

3 25/64"[86.11]

3 45/64"[94.05]

7/16"[11.11]

3/16"[4.76]

1/4"[6.35]

1/4"[6.35]

3 1/4"[82.55]

5/16"[7.94]

Ø 9/16"[Ø 14.29]

JP450T (with eyelets: EYJP450T)Retrofit Waterstop System(Includes all batten bars and anchors)75 ft Head of H20

Page 7

3/16"[4.76]

2 15/32"[62.88]

4 15/32"[113.68]

19/32"[14.99]

JP621LLarge Movement Retrofit(Includes all batten bars and anchors)75 ft Head of H20

JP540LExterior Applied Corner Retrofit Waterstop(Includes all batten bars and anchors)50 ft Head of H20

JP325T (with eyelets: EYJP325T)Retrofit Waterstop System(Includes all batten bars and anchors)75 ft Head of H20

Slab to Slab Connection

Page 8: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

5/8"[15.88]

1/4"[6.35]

3/8"[9.53]

1"[25.4]

Integrated Cap SystemsIntegrated Waterstop and Joint SealantIntegrated expansion board cap waterstop

systems are designed to replace post-ap-plied joint sealant, and provide a fluid-tight internal seal like a traditional waterstop with a one-step, integrated unit.

Earth Shield® expansion board cap wa-terstop is installed on top of conventional expansion board filler. The expansion board acts as the form; therefore, no form splitting is necessary. This greatly accelerates the project schedule and provides a long last-ing, attractive finished concrete joint.

Earth Shield® screed key cap slides over the top of metal screed key, eliminating the need for sealant.

• No split forms• Accelerated installation• No sawcutting or sealant• No joint finishing• Long life• UV and abrasion resistant

JPEB375 (with eyelets: EYJPEB375)3/4” Expansion Board Cap Waterstop50 ft Head of H20

JPEB350 (with eyelets: EYJPEB350)1/2” Expansion Board Cap Waterstop50 ft Head of H20

JP158Screed Keyway Cap

Page 8

JP1225 (with eyelets: EYJP1225)Screed Key Waterstop50 ft Head of H20

JPEB375R (with eyelets: EYJPEB375R)3/4” Exp. Board Cap Retrofit Waterstop(Includes all batten bars and anchors)50 ft Head of H20

Page 9: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Standard FabricationsPage 9

JPEB350X1 Flat CrossJPEB375X1 Flat CrossJP1225X1 Flat Cross

JPEB350T1 Flat TeeJPEB375T1 Flat TeeJP1225T1 Flat Tee

JPEB350L3 Outside CornerJPEB375L3 Outside CornerJP1225L3 Outside Corner

10400 — JPEB375R to JPEB375 Transitional Flat Tee

JPEB350L3 Inside CornerJPEB375L3 Inside CornerJP1225L3 Inside Corner

JPEB350L1 Flat EllJPEB375L1 Flat EllJP1225L1 Flat Ell

10400 — JPEB375 to JP1225 Transitional Flat Cross

10400 — JPEB375 to JP621L Transitional Flat Tee

JPEB375RL1 Outside Corner(Includes all batten bars and anchors)

JPEB375RL2 Inside Corner(Includes all batten bars and anchors)

10400 — JPEB375 Rollover Curb

Page 10: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

WWW.EARTHSHIELD.COM

Made in the U.S.A.Waterstop for Chemical, Industrial,

& Environmental Applications

J P SPECIALTIES, INC.

Manufactured with pride by

Page 11: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

WWW.EARTHSHIELD.COM

Made in the U.S.A.Waterstop for Chemical, Industrial,

& Environmental Applications

JP Specialties, Inc. manufactures a wide range of high-quality waterstop and waterstop accessories for the concrete construction industry. Our Earth

Shield® line of chemical resistant waterstop is designed to offer solutions for today’s unique regulatory compliance needs. Our waterstop weld-ing equipment is used industry-wide as the standard for quality, high tensile strength waterstop welds. Knowing that a waterstop will only

offer a fluid-tight barrier if change of directions are done properly, JP Specialties has been a leader since 1954 in Prefabricated

Waterstop Modules and Shop Made Fittings.

Page 12: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

3/16"[4.76]

2 15/32"[62.88]

4 15/32"[113.68]

19/32"[14.99]

6"[152.4]

9/16"[14.29]

3/16"[4.76]

3/16"[4.76]

7/16"[11.11]

1/4"[6.35]

Ø 9/16"[Ø 14.29]

9"[228.6]

9/16"[14.29]

7/16"[11.11]

1/4"[6.35]

3/16"[4.76]

3/16"[4.76]

Special Shapesfor Large Movement Joints

Base Seal (aka Rearguard)for Flatwork and Bund Wall Applications

27/64"[10.82]

3/16"[4.76]

19/32"[14.99]

5/8"[15.88]

39/64"[15.63]

1 59/64"[49.01]

9"[228.6]

74° 99°

R 3/4"[R 19.05]

Base seal waterstop is ideal for flat pavement jobs such as runways, large containment slabs, etc. Base seal waterstop is by far the easiest waterstop to install... Simply lay the waterstop directly on the compacted subgrade, place and finish concrete, and create control joint using saw cut or other method. The base seal provides a permanent, life-of-structure seal at the bottom of the joint.

Base seal is suitable for construction, contraction (control), and expansion joints. Base seal should not be used on jobs that make interior wall transitions as the part is non-symmetrical and therefore cannot function correctly. For large hydrostatic head pressures (>50 foot) ribbed centerbulb should be used instead.

JP2119” Base Seal Waterstop75 ft Head of H20

JP678 (with eyelets: EYJP678)6” Tear Web Waterstop125 ft Head of H20

JP978 (with eyelets: EYJP978)9” Tear Web Waterstop175 ft Head of H20

Earth Shield® tear web waterstops are designed for large joint movements such as tank foundations. Tear web is suitable for expansion joints. For construction and con-traction (control) joints, ribbed centerbulb should be used instead.

Page 12

JP621LLarge Movement Retrofit(Includes all batten bars and anchors)75 ft Head of H20

Page 13: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

JP2119” Base Seal Waterstop75 ft Head of H20

JP978 (with eyelets: EYJP978)9” Tear Web Waterstop175 ft Head of H20

6"[152.4]

1/4"[6.35]

5/8"[15.88]

6"[152.4]

3/4"[19.05]

3/8"[9.53]

9"[228.6]

3/8"[9.53] 1"

[25.4]

1"[25.4]

Ø 1 1/2"[Ø 38.1]

3/4"[19.05]

3/8"[9.91]

9"[228.58]

11 7/8"[300.23]

1"[25.4]

3/8"[9.53]

3/4"[19.05]

Ø 1 1/2"[Ø 38.1]

Dumbbell waterstop is usually used in below grade applications, where limited movement is expected. Dumbbell waterstop can be installed in construction and contraction (con-trol) joints; whereas, dumbbell cen-terbulb can be installed in construc-tion, control, and expansion joints.

The large centerbulb (1-1/2” outer diameter) on the JP949 (and JP1149) waterstop profile, coupled with the outstanding mechanical properties of our thermoplastic vulcanizate and large endbulb anchors, enable the product to withstand large -scale joint movement (seismic, settlement, etc.).

JP114912” Dumbbell Centerbulb Waterstop225 ft Head of H20

JP9499” Dumbbell Centerbulb Waterstop150 ft Head of H20

JP9489” Dumbbell Waterstop150 ft Head of H20

JP6486” Dumbbell Waterstop125 ft Head of H20

JP6476” Dumbbell Waterstop125 ft Head of H20

Page 13

DumbbellLarge Web Thickness for Heavy Concrete

Page 14: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Page 14

Retrofit Column and Pipe FittingEarth Shield® has solved a long-standing problem for engineered concrete structures with circular protrusions, such as columns, pipes, piers, and pilasters. The problem: how to permanently seal the concrete joint when cast-in-place concrete is formed against an existing circular member. The solution: Earth Shield® Column & Pipe Fitting (part no. JP320LC1.XX* [*XX is the diameter in inches]) manufactured with a flexible, chemical-resistant polymer and stainless steel anchoring hardware. A single laborer on the job site can quickly install the column fitting and its associated hardware. Simply apply an epoxy gel bed to the existing sur-face; place the polymer ring into the epoxy gel bed; heat weld the single opening on the polymer ring using a waterstop splicing iron; and finally, complete the system with the stainless steel closure ring.

The Earth Shield® system functions as an internal dam, centrally located within the cast concrete, to stop ag-gressive chemicals, solvents and hot petroleum oils from penetrating the joint. By preventing the passage of hazardous liquids the Earth Shield® Column Fitting provides facility owners, engineers, and contractors with the necessary EPA-mandated containment compliance (EPA Title 40 CFR 265.193). Of course, the system pre-vents the passage of water as well. The mechanical properties of the polymer, plus the tear-web design of the JP320L profile, enable the column fitting to function equally well in expansion (isolation) joints and construction joints.

Page 15: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Page 15

Metallic Waterstop for Extreme Chemical Resistance

Earth Shield® Chemical Resistant WaterstopP.O. Box 1507, Lake Elsinore, CA 92531

Phone: 888-836-5778; Fax: 951-674-1315E-mail: [email protected]

Web: www.earthshield.com

aterstops play a critical role in the integrity ofconcrete structures. They provide a fluid-tight

diaphragm when embedded in, and running throughconcrete joints.

Earth Shield® Metallic Waterstop can stop even themost corrosive fluids in their tracks, even at severelyelevated temperatures. A variety of metals, grades,and gauges are available. Earth Shield utilizes 20gauge 316 low carbon as our standard alloy, whichoffers broad spectrum corrosion resistance to mostaggressive media, and is virtually untouched by thedeleterious effects of ozone, making it an ideal choicefor ozone contactor structures used in modern watertreatment plants.

Earth Shield Stainless Steel Waterstop is availablein many standard shapes and sizes (see inside),including profiles for new construction and retrofit.All change of direction fabrications can bepremanufactured leaving only straight butt weldingfor the field.

JP Specialties has been the respected innovator inthe waterstop industry since 1954. We are knownworldwide for our high-quality waterstop, and wehold the patent on the ST-10® In Line WaterstopSplicing Table and the XLT2000 WaterstopFabrication Table — the equipment used tomechanically weld thermoplastic waterstops.www.earthshield.com/sswaterstop.html

Earth Shield does fabricate custom waterstop profiles forour engineering and owner clients. Feel free to contact usdirectly if your project requires a fabricated profile thatyou do not see listed in our catalog. Additional grades andgauges are available (including copper, galvanized, carbonsteel and others).

J P SPECIALTIES, IN

C.

The Hydrocarbon Resistant Choice

Earth Shield® CR125 Chemical Resistant Strip Waterstopis designed to prevent the passage of aqueoushydrocarbons through non-moving concrete joints inenvironmental engineered concrete structures. Theproduct aggressively bonds to most substrates and isunaffected by rain or wet conditions during installation.www.jpspecialties.com/Waterstop_for_Concrete_Joints/jpproduct.html

Type 125CRChemical ResistantStrip Waterstop

Distributed by:

Earth Shield® Type 125CRStrip Waterstop

Typical Physical PropertiesSpecific Gravity, 77°F 1.40ASTM D71

Ductility, 77°F 15%ASTM D113

Softening Point 300°FASTM D36

Penetration, Cone 77°F 60-70 mm150 gm. 5 sec. ASTM D217

Service Temp., °F -30° to 200°F

Color Gray

Type 20 Packaging 6 rolls per carton100 lft. per carton1/2" x 1-1/4" x 16'8"

Type 125CR

JP Specialties, Inc.P.O. Box 1507, Lake Elsinore,CA 92531Phone: 800-821-3859Fax: [email protected]

Earth Shield® is a registered trademark of JP Specialties, Inc.

Fluid Concentration Result RecommendationGasolineJet A FuelJP4 FuelJP8 FuelKeroseneMotor OilTransmissionFluidBrake FluidCooking OilMineral SpiritsMethyl EthylKetoneTolueneTrichloroethaneAlcoholAntifreezeRunway De-IcerUreaDetergentInsecticideFertilizerAcrylic Acid,Glacial

100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended

100% Some Swelling Conditional use100% No Degradation Recommended100% No Degradation Recommended100% Swelling, cracking Do not use

100% Swelling, cracking Do not use100% Swelling, cracking Do not use100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended100% No Degradation Recommended100% Swelling, cracking Do not use

1-1/4”32 mm

1/2”13 mm

Earth Shield® Chemical Resistant Waterstop manufactured by JP Specialties, Inc. 551 Birch Street, Lake Elsinore, CA 92530

888-836-5778 • FAX 951-674-1315 • www.earthshield.com • [email protected]

Novolac Epoxy

VEN 1000 — High Chemical Resistant Epoxy Gel

VEN 500 — Chemical Resistant Epoxy Gel Earth Shield® VEN 1000 and VEN 500 are trowel grade epoxy gels designed to adhere Earth Shield Retrofit Waterstop (part no. JP 320L, JP 336L, JP 325T, JP 450T, et al) to existing concrete surfaces, as well as a variety of maintenance and bonding applications requiring extreme chemical resistance. Applications • Primary and secondary

containment • Refineries • Fueling areas • Pulp & paper • … And many more! VEN 1000 Physical Properties Adhesion Strength

2,800 psi

Color Light gray Kit Size 1 gallon Flash Point 250°F Specific Gravity (Resin)

1.51

Specific Gravity (Hardener)

.95

Volatile Organic Compounds

0 grams per liter

Weight Per Gallon

11.39 lbs.

Pot Life* at 40°F 5 hours, 40 min.

VEN 1000 Physical Properties Pot Life* at 75°F 1 hour Pot Life* at 90°F 25 minutes High Temp. Dry Service

450°F

High Temp. Splash/Spill Service

360°F

High Temp. Immersion Service

300°F

VEN 500 Physical Properties Adhesion Strength

2,850 psi

Color Light gray Kit Size 1 gallon Flash Point 250°F Specific Gravity (Resin)

1.36

Specific Gravity (Hardener)

.82

Volatile Organic Compounds

0 grams per liter

Weight Per Gallon

10.20 lbs.

Pot Life* at 40°F 8 hours, 30 min.

Pot Life* at 75°F 45 minutes

Pot Life* at 90°F 30 minutes

High Temp. Dry Service

250°F

High Temp. Splash/Spill Service

190°F

High Temp. Immersion Service

150°F

Mixing Instructions 1. Place all of part “B” into part

“A” container. 2. Mix thoroughly until the

material is uniform in color (no streaks). Scrape sides of can to insure there are no unmixed areas. Unmixed product will not properly cure.

3. Once mixed, remove putty from can and place on rolling

tray, cardboard, or wooden board. Spread putty over surface of board. *Due to exothermic heat, putty left in container will accelerate the cure time, causing epoxy to harden too quickly. Try to keep the epoxy depth below 3/8” to prolong the pot life.

Coverage • 1/8” depth by 3” wide: 50 lft • 1/8” depth by 4.5” wide: 37.5

lft Placement Prepare existing concrete by grinding away any irregularities. Clean concrete by using wire brush, needle gun, high-pressure water or sand blasting. Remove all grease and laitance. For JP 320L & JP 336L Apply continuous bed of epoxy paste using a 1/4” square notched trowel to provide approximately 1/8” finished depth by 3” wide bed of epoxy for JP 320L and JP 336L Retrofit Waterstop profiles.

For JP 325T Apply continuous bed of epoxy paste using a 1/4” square notched trowel to provide approximately 1/8” finished depth by 3.5” wide bed of epoxy for JP 325T Retrofit Waterstop profile.

Other Fine Earth Shield® Products

Page 16: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Page 16

Base SealJP211JP621L

RetrofitJP320LJP325TJP336LJP450TJP500JP540LJP621LJPEB375R

Ribbed CenterbulbJP436JP636JP936

Page 17: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Page 17

DumbbellJP647JP648JP948JP949

JP1149

Integrated CapJP158

JPEB350JPEB375

JPEB375RJP1225

Tear WebJP678JP978

Page 18: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

Waterstop Shop Made FittingsEnsure A Quality, Leak-Proof ProjectTesting has shown that the majority of water-

stop failures are caused when the waterstop must make directional changes. This is because directional changes, or fittings as they are com-monly known, require special tools and skills that are not generally required for welding the straight edges of waterstops. Consequently, the fittings are either made wrong (edge welding); there is no tensile strength in the welds; the material is charred, burnt or otherwise contaminated; or the worker’s lack of experience causes unreliable welds. Shop Made Fittings are machine welded using an XLT-2000 Waterstop Splicing Table. JP Specialties invented the XLT-2000 and retains the patent on the technology. The XLT-2000 applies force evenly, creating monolithic, homogeneous and contaminant-free welds.

Shop Made Fittings are recognized and specified worldwide by major engineering firms. The U.S. Army Corps of Engineers also specified Shop Made Fittings in the July, 1995 revision of CEGS Section 03250.

Shop Made Fittings are specified because they work. Edge welding waterstop seriously compro-mises the integrity of any project. Even the lim-ited movement of concrete during the coefficient of expansion and contraction can be too much for edge welded waterstop. The edge welded waterstop lacks the proper tensile strength and does not maintain the characteristics of the parent material (bulb or rib continuity). Conse-quently, the waterstop often tears at the most critical junction: the change of direction. Since all waterstops are designed to act as a continuous, fluid-tight diaphragm which fluids (generally wa-ter) traverse, the structure that uses edge welded waterstop will naturally leak, as fluids migrate to any tears in the weld and pass through to the other side of the joint.

Structures that use Shop Made Fittings will sig-nificantly reduce these waterstop failures. The tensile strength of the weld will be at least 80% of the parent material.

Page 18

Page 19: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

NSF/ANSI Standard 61 was developed to estab-lish minimum requirements for the chemical contami-nants and impurities that are indirectly imparted to drinking water from prod-ucts, components, and materials used in drinking water systems.

Standard 61 is intended to cover specific materi-als or products that come into contact with drinking water, drinking water treatment chemi-cals, or both. The focus of Standard 61 is evalu-ation of contaminants or impurities imparted indi-rectly to drinking water.

In the U.S., 47 of 50 states have legislation that requires compliance with NSF/ANSI Standard 61. Products that are NSF Certified against NSF/ANSI Standard 61 dem-onstrate compliance with both Canadian and U.S. Plumbing Codes. NSF Certification and Testing is widely accepted. NSF data is recognized by ASSE, BOCA, IAPMO, ICBO-ES, SBCCI, City of Los Angeles and many others.

Trust Your Critical Water Projects to Earth Shield® — NSF Standard 61 Certified, EPA Compliant WaterstopWater is arguably the most valuable resource in the world. Today’s water treatment, distribu-tion, and storage projects are under ever-increasing layers of regulations and requirements, one of the foremost being that components and materials that contact potable water not have potential adverse human effects.

Earth Shield® TPV Waterstop, with NSF 61 certification, is the perfect choice for today’s critical water proj-ects, and in particular drinking water projects.

Page 19

Page 20: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

J P SPECIALTIES, INC.

Earth Shield® Chemical Resistant WaterstopPhone: 800-821-3859; 951-763-7077

Fax: 951-763-7074

www.earthshield.com

Visit Earth Shield® on the Web atwww.earthshield.com

Earth Shield® Waterstop Limited WarrantyJP Specialties, Inc. warrants to the Buyer that this prod-uct is new and will be free from defects and will perform as represented in writing subject to the two (2) following conditions: First, the application of the product and the concrete construction practices used in the application are in accordance with JP Specialties, Inc. recommendations; and, Second, the Buyer has selected the proper product for the specific application required.

Any information supplied in good faith by JP Specialties, Inc. with respect to its products is believed to be correct. JP Specialties, Inc. Makes no representation or warranties, expressed or implied, as to the accuracy or completeness of such information.

The exclusive remedies of the Buyer and the limit of the liability of JP Specialties, Inc. from any and all losses or damages resulting from the use of this product shall be either full refund of the purchase price to the Buyer of this product or the replacement of the quantity of product purchased by the Buyer at the discretion of JP Specialties, Inc.

All supplied testing data has been performed by indepen-dent testing laboratories.

Publication Date March 2013 • Earth Shield®, The Primary Choice for Secondary Containment®, and CAPwrap® are registered trademarks of JP Specialties, Inc. • All material copyright 2013 JP Specialties, Inc. • All rights reserved

AvailabilityNational and International WarehousesEarth Shield® Chemical Resistant Waterstop is readily available from a variety of sources:• Preferred Regional Stocking Partners —

We are partners with some of the very best Concrete Accessories Distributors in the world. All our preferred partners have large stocking inventories and are factory trained to provide the utmost in on-site assistance.

• Distributor Sales — Earth Shield® can be special ordered from many distributor sales channels throughout the world.

• Factory Direct — Earth Shield® may be contacted directly for project quotation and product purchase (call 888-836-5778).

• Web Store — Earth Shield® products can be ordered directly on our web store at http://waterstop.enstore.com

Distributed by:

Services• Project and Product Certification — We assist

the Design Engineer and Project Owner with individual project and product certification. When you specify our waterstop, you can be assured it is the correct product for your application.

• Take-off Assistance — For the Contractor. • Shop Drawings— 3-D isometric and 2-D CAD

details are available to assist the project.• On-site waterstop welding certification class

— $500.00 flat fee• On-site waterstop installation assistance —

$1,000.00 per day• Telephone and Web-based assistance —

Always FREE

www.facebook.com/waterstop

Page 21: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

SECTION 03150 — WATERSTOPS FOR CONCRETE JOINTS — rev. 7/17/14 ***** MasterFormat™ 2004 — Section 03 15 13 *****

Note to Designer: Earth Shield® Chemical Resistant Waterstop is manufactured from proprietary compounds and fully-crosslinked polymers. It is strongly suggested that you specify Earth Shield as a sole source. There are no equals. !This specification is available in a variety of computer formats on CD-ROM or DVD. Contact Earth Shield Technical Sales for more information. It can also be found on the web at www.earthshield.com. ! !Suggested Short Form Guide Specification !Chemical Resistant TPV Waterstop for Concrete Joints Waterstop indicated in drawings and specifications for contraction (control), expansion, and construction joints shall be Earth Shield® Thermoplastic Vulcanizate (TPV) Part No. #### [Designer insert appropriate part number here] as manufactured and available from JP Specialties, Inc. — Murrieta, CA, USA 92562 — Phone 800-821-3859; 951-763-7077; Fax 951-763-7074; www.earthshield.com; E-mail [email protected]

1. Thermoplastic Vulcanizate (TPV) Waterstop shall be certified for use in potable water per NSF/ANSI Standard 61. Third-party certified documentation to be provided by manufacturer.

2. Thermoplastic Vulcanizate (TPV) Waterstop shall be independently GreenSpec listed. Third-party documentation to be provided by manufacturer.

3. No equals or substitutions allowed. !TPV Waterstop Shop Made Fittings for Directional Changes Intersection and change of direction waterstops shall be factory fabricated as manufactured and available from JP Specialties, Inc. — Murrieta, CA, USA 92562 — Phone 800-821-3859; 951-763-7077; Fax 951-763-7074; Web www.earthshield.com; E-mail [email protected] and installed at all locations on the drawing by the Contractor. The Contractor shall only weld straight lengths of waterstop with all change of directions (fittings) being fabricated and supplied by Manufacturer.

1. No equals or substitutions allowed. !!!Suggested Long Form Guide Specification !PART 1 GENERAL !1. Provision Includes

A. Embedded waterstop in concrete including contraction, expansion and construction joints creating a continuous diaphragm to prevent the passage of fluid.

B. The use of nonmetallic waterstops for use in concrete joints subjected to chlorinated water, sea water, oils, solvents, acids, salts, fuels and many other aggressive chemicals and fluids.!

1. ReferencesThe publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.

A. American Society for Testing and Materials (ASTM)1. ASTM D 395 — Test Methods for Rubber Property – Compression Set.2. ASTM D 412 — Test Methods for Vulcanized Rubber and Thermoplastic Rubbers and

Thermoplastic Elastomers — Tension.3. ASTM D 471 — Test Method for Rubber Properties – Effects of Chemicals.4. ASTM D 624 — Test Method for Tear Strength of Conventional Vulcanized Rubber and

Thermoplastic Elastomer.5. ASTM D 746 — Test Method for Brittleness Temperature of Plastics by Impact.

PAGE � OF �1 6

Page 22: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

SECTION 03150 — WATERSTOPS FOR CONCRETE JOINTS — rev. 01/29/13 ***** MasterFormat™ 2004 — Section 03 15 13 *****

6. ASTM D 792 — Test Method for Specific Gravity (Gravity Density) and Density of Plastics by Displacement.

7. ASTM D 1171 — Test Method for Ozone Resistance at 500 pphm.8. ASTM D 2240 — Test Method for Shore Hardness.

B. Federal Specifications1. COE CEGS-03250 July 1995 Guide Specification for Military Construction.2. EPA Title 40 CFR Section 265.193.

C. American Concrete Institute1. ACI 350.2R-04 — Concrete Structures for Containment of Hazardous Wastes.

D. NSF International1. NSF/ANSI Standard 61Certification for Drinking Water System Components — Health Effects.

E. Canadian Council of Ministers of the Environment1. Environmental Code of Practice for Aboveground and Underground Storage Tank Systems

Containing Petroleum and Allied Petroleum Products.F. BuildingGreen, Inc.

1. GreenSpec® — GreenSpec® Directory, 6th Edition (and later).!3. Submittal Procedures

A. Chemical Resistant TPV Waterstop1. Earth Shield TPV Waterstop submittal shall contain the following:

a. Samples of each size and shape to be used.b. Plate drawings of the waterstop profile indicating all dimensions.c. Shop drawings of shop made fittings to be provided by the manufacturer or prepared by the

contractor.d. Certified chemical resistance per ASTM D 471.e. Copy of independent certification to NSF/ANSI Standard 61 Certification for Drinking Water

System Components — Health Effects.f. Copy of independent testing to ASTM D 1171 Ozone Resistance to 500 pphm concentration.g. Manufacturer’s Literature, MSDS sheets, installation, safety, and splicing instructions.h. Certificate of compliance to physical properties outlined in this specification with third-party

independent test reports (all testing reports within three years of date of submittal).!2. Chemical Resistant TPV Waterstop and Splices — Specimens identified to indicate manufacturer,

type of material, size, quantity of material, and shipment or lot represented. Each sample shall be not less than 6 inches long of each type, size, and lot furnished. One splice sample of each size and type for every 50 splices made in the shop and every 10 splices made at the job site. The splice samples shall be made using straight run pieces with the splice located at the mid-length of the sample and finished as required for the installed waterstop. The total length of each splice shall be not less than 12 inches long.!

4. Delivery and StorageMaterial delivered and placed in storage shall be stored off the ground and protected from moisture, dirt, and other contaminants.!PART 2 PRODUCTS !1. Chemical Resistant TPV WaterstopIntersection and change of direction waterstops shall be factory fabricated.

A. Manufacturer:JP Specialties, Inc. — Murrieta, CA, USA 92562 — Phone 800-821-3859; 951-763-7077; Fax 951-763-7074; Web www.earthshield.com; E-mail [email protected]!

PAGE � OF �2 6

Page 23: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

SECTION 03150 — WATERSTOPS FOR CONCRETE JOINTS — rev. 7/17/14 ***** MasterFormat™ 2004 — Section 03 15 13 *****

B. Chemical Resistant Non-Metallic Waterstops — Non-metallic waterstops shall be manufactured from a fully cross-liked thermoplastic vulcanizate (TPV), containing no plasticizer, mineral fillers, scrap or reclaimed material.

1. Thermoplastic Vulcanizate (TPV) Waterstop shall conform to EPA Title 40 CFR Section 265.193. The suitability of the waterstop for a specific application should be determined by specific testing for that particular requirement by ASTM D 471.

2. Thermoplastic Vulcanizate (TPV) Waterstop shall be certified for use in potable water per NSF/ANSI Standard 61. Third-party certified documentation to be provided by manufacturer.

3. Thermoplastic Vulcanizate (TPV) Waterstop shall be independently GreenSpec listed. Third-party documentation to be provided by manufacturer.!

Thermoplastic Vulcanizate (TPV) Waterstop shall conform to the following typical physical properties:

Unless otherwise specified or indicated on the drawings provide the following types: 1. Part No. JP436 — 4” x 3/16” ribbed centerbulb, as manufactured by JP Specialties, Inc. (all-

purpose waterstop; if specified with factory installed brass eyelets use part no. EYJP436) ! 2. Part No. JP636 — 6” x 3/16” ribbed centerbulb, as manufactured by JP Specialties, Inc. (all-

purpose waterstop; if specified with factory installed brass eyelets use part no. EYJP636) ! 3. Part No. JP936 — 9” x 3/16” ribbed centerbulb, as manufactured JP Specialties, Inc. (all-purpose

waterstop; if specified with factory installed brass eyelets use part no. EYJP936) ! 4. Part No. JP678 — 6” x 3/16” ribbed tear web, as manufactured by JP Specialties, Inc. (for

extreme joint movement; if specified with factory installed brass eyelets use part no. EYJP678) ! 5. Part No. JP978 — 9” x 3/16” ribbed tear web, as manufactured by JP Specialties, Inc. (for

extreme joint movement; if specified with factory installed brass eyelets use part no. EYJP978) ! 6. Part No. JP211 — 9” x 3/16” base seal, as manufactured by JP Specialties, Inc. (for runway and

pavement applications) ! 7. Part No. JP320L — 3” x 3/16” tear web retrofit, as manufactured by JP Specialties, Inc. (for

joining concrete to existing surface; if specified with factory installed brass eyelets use part no. EYJP320L) !

Property Test Method Required ResultsSpecific Gravity ASTM D 792 .96Shore A Hardness (5 sec.) ASTM D 2240 90±3 at 25°C (77°F)Tensile Strength ASTM D 412 2,300 psiUltimate Elongation ASTM D 412 530%100% Modulus ASTM D 746 1,000 psiTear Strength ASTM D 624 278 pli at 25°C (77°F)Compression Set ASTM D 395 29% at 25°C (77°F)Brittle Point ASTM D 746 -61°C (-78°F)Drinking Water Safe Certified for use in potable water

Ozone Resistance ASTM D 1171 Passed, no cracking at 500 pphm Chemical Resistance ASTM D 471 Meet or exceed specific testing

standards for contained fluids as required by Owner and certified by Manufacturer.

Green Certification GreenSpec Approved

NSF/ANSI 61 !

PAGE � OF �3 6

Page 24: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

SECTION 03150 — WATERSTOPS FOR CONCRETE JOINTS — rev. 01/29/13 ***** MasterFormat™ 2004 — Section 03 15 13 *****

8. Part No. JP336L — 3” x 3/16” retrofit, as manufactured by JP Specialties, Inc. (for joining concrete to existing surface; if specified with factory installed brass eyelets use part no. EYJP336L) !

9. Part No. JP621L — 4-1/2” x 3/16” large movement retrofit, as manufactured by JP Specialties, Inc. (for joining concrete to existing surface; large shear movements) !

10. Part No. JP325T — 3” x 3/16” T-shaped retrofit, as manufactured by JP Specialties, Inc. (for joining concrete to existing surface; if specified with factory installed brass eyelets use part no. EYJP325T) !

11. Part No. JP450T — 5” x 3/16” T-shaped retrofit, as manufactured by JP Specialties, Inc. (for joining concrete to existing surface; if specified with factory installed brass eyelets use part no. EYJP450T) !

12. Part No. JP500 — 4.5” x 3/16” post-applied flat retrofit, as manufactured by JP Specialties, Inc. (for post-applied, surface sealing) !

13. Part No. JP540L — 4.5” x 3/16” post-applied corner retrofit, as manufactured by JP Specialties, Inc. (for for post-applied, surface to wall sealing) !

14. Part No. JP647 — 6” x 1/4” dumbbell, as manufactured by JP Specialties, Inc. (for construction joints) !

15. Part No. JP648 — 6” x 3/8” dumbbell, as manufactured by JP Specialties, Inc. (especially designed for Carollo Engineers [construction joints]) !

16. Part No. JP948 — 9” x 3/8” dumbbell, as manufactured by JP Specialties, Inc. (for construction joints) !

17. Part No. JP949 — 9” x 3/8” dumbbell centerbulb, as manufactured by JP Specialties, Inc. (especially designed for Carollo Engineers [expansion joints]) !

18. Part No. JP1149 — 12” x 3/8” dumbbell centerbulb, as manufactured by JP Specialties, Inc. (especially designed for Carollo Engineers [expansion joints]) !

19. Part No. JP158 — 1” screed key cap, as manufactured by JP Specialties, Inc. (designed for keyed joints) !

20. Part No. JP1225 — 1” integrated screed key cap seal waterstop, as manufactured by JP Specialties, Inc. (designed for keyed joints; if specified with factory installed brass eyelets use part no. EYJP1225)

21. Part No. JPEB350 — 1/2” integrated cap seal waterstop, as manufactured by JP Specialties, Inc. (designed for expansion joints; if specified with factory installed brass eyelets use part no. EYJPEB350) !

22. Part No. JPEB375 — 3/4” integrated cap seal waterstop, as manufactured by JP Specialties, Inc. (designed for expansion joints; if specified with factory installed brass eyelets use part no. EYJPEB375) !

23. Part No. JPEB375R — 3/4” integrated cap seal retrofit waterstop, as manufactured by JP Specialties, Inc. (designed for expansion joints; if specified with factory installed brass eyelets use part no. EYJPEB375R) ! !!

PART 3 EXECUTION !1. Waterstop, Installations and Splices — Waterstops shall be installed at the locations shown to form a

continuous fluid-tight diaphragm. Adequate provision shall be made to support and completely protect the waterstops during the progress of the work. Any waterstop punctured or damaged shall be repaired or replaced. Exposed waterstops shall be protected during application of form release agents to avoid being coated. Suitable guards shall be provided to protect exposed projecting edges and ends of partially embedded waterstops from damage when concrete placement has been discontinued. Splices shall be made by certified, trained personnel using approved equipment and procedures.

PAGE � OF �4 6

Page 25: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

SECTION 03150 — WATERSTOPS FOR CONCRETE JOINTS — rev. 7/17/14 ***** MasterFormat™ 2004 — Section 03 15 13 *****

A. Non-Metallic Shop Made Fittings — Fittings shall be shop made using a machine specifically designed to mechanically weld the waterstop. A miter guide, proper template (profile dependent), and portable power saw shall be used to miter cut the ends to be joined to ensure good alignment and contact between joined surfaces. The splicing of straight lengths shall be done by squaring the ends to be joined and using an ST-10® waterstop splicing tool. Continuity of the characteristic features of the cross section of the waterstop (ribs, tabular center axis, protrusions, etc.) shall be maintained across the splice.

B. Thermoplastic Vulcanizate Waterstop — The splicing of straight lengths shall be done by squaring the ends to be joined and using an ST-10® waterstop splicing tool utilizing a thermoplastic splicing iron with a non-stick surface specifically designed for waterstop welding. The correct temperature (410°F to 430°F) shall be used to sufficiently melt without charring the plastic. The spliced area, when cooled, shall show no signs of separation, holes, or other imperfections when bent by hand in as sharp an angle as possible.!

2. PreparationA. Uncoil waterstop 24 hours prior to installation for ease of handling and fabrication.B. Position waterstop to ensure proper distance from steel reinforcing bars to prevent rock pockets and

honeycomb (see installation section 3.04).C. Protect waterstop from damage during progress of work.D. Clean concrete joint after first pour to remove debris and dirt.!

3. Examination/InspectionA. Prior to placement of concrete notify engineer for field inspection approval.B. Inspect waterstop and field splices for defects and conformance to Quality Assurance Standard section

3.05.C. Upon inspection of waterstop installation, replace any damaged or unacceptable waterstop and

dispose of defective material.!4. Installation

A. Position waterstop in joint as indicated on drawings.B. Center waterstop on joint, with approximately one-half of waterstop width to be embedded in concrete

on each side of the joint.C. Allow clearance between waterstop and reinforcing steel of a minimum two times the largest aggregate

size. Prevent rock pockets and air voids caused by aggregate bridging.D. Ensure centerbulb is not embedded at expansion joints.E. Secure waterstop in correct position using optional factory-installed brass eyelets (or JPS hog rings

crimped between last two ribs on 12 inch maximum centers), and wire tie to adjacent reinforcing steel. Center-to-center spacing may be increased upon written request and approval from ENGINEER.

F. Carefully place concrete without displacing waterstop from proper position.G. Thoroughly and systematically vibrate concrete in the vicinity of the joint, and to maximized intimate

contact between concrete and waterstop.H. After first pour, clean unembedded waterstop leg to ensure full contact of second concrete pour.

Remove laitance, spillage, form oil and dirt.!5. Quality Assurance — Edge welding will not be permitted. Centerbulbs shall be compressed or closed when

welding to non-centerbulb type. Waterstop splicing defects which are unacceptable include, but are not limited to the following:

A.Tensile strength not less than 60 percent of parent sections.B.Free lap joints.C.Misalignment of centerbulb, ribs, and end bulbs greater than 1/16 inch.D.Misalignment which reduces waterstop cross section ore than 15 percent.E.Bond failure at joint deeper than 1/16 inch or 15 percent of material thickness.F.Misalignment of waterstop splice resulting in misalignment of waterstop in excess of 1/2 inch in 10 feet.G.Visible porosity in the weld.

PAGE � OF �5 6

Page 26: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

SECTION 03150 — WATERSTOPS FOR CONCRETE JOINTS — rev. 01/29/13 ***** MasterFormat™ 2004 — Section 03 15 13 *****

H.Charred or burnt material.I.Bubbles or inadequate bonding.J. Visible signs of splice separation when cooled splice (24 hours or greater) is bent by hand at sharp

angle.!!!END OF SECTION!!

All information is presented in good faith and the results are believed to be accurate. All testing was done independently of Earth Shield and JP Specialties, Inc.; therefore, neither Earth Shield nor JP Specialties, Inc. makes any guarantee as to the testing data accuracy or the results obtained. !! NSF mark denotes NSF Standard 61 certification. !

! ! ! !

PAGE � OF �6 6

Page 27: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

NOTE: It is highly recommended that you use a JP Specialties, Inc. ST-10® Waterstop Splicing Machine. The following directions are for welding WITHOUT an ST-10. The ST-10 will greatly enhance the quality of the welds and reduce welding time.

FIELD FABRICATIONS: Following is the proper procedure, as recommended by JP Specialties, Inc. for field splicing nonmetallic waterstops.

Provide shop made fabricated waterstop ells, tees, crosses and transitions leaving only straight 1. butt joint splices for the field. Always cut ends square before welding waterstop. Never weld to extruded end.

Use a work table to create field splices. Table should be solid, have access to 115 volt power 2. supply, and have jigs and fixtures to aid splicing.

Cut ends square, using a razor knife or circular saw equipped with a carbide tipped blade (10" 3. diameter with 40 teeth) to ensure matching edges.

Preheat Teflon covered splicing iron (JP 214 or JP 414) to 350-380ºF for PVC or 410 to 430ºF for 4. TPER / TPV. It is recommended that you verify the temperature with a digital thermometer.

Place iron between butt ends. Keep waterstop in place until approximately 3/16" bead forms 5. on each side of waterstop. Quickly remove splicing iron and hold waterstop ends together until they bond (approximately 3 to 5 minutes or cool to the touch). Cold water may be sprayed on waterstop to expedite the bond. Do not move, bend, stretch or stress the splice before the recommended bond time. When welding TPER / TPV, if you do not join the ends quickly, the melted material will skin over, resulting in an inadequate bond.

When fabricating waterstop into horizontal tees, ells or crosses always miter the ends at a 45 6. degree angle so the continuity of the ribs and/or center bulb are maintained. This will also pro-duce a much stronger joint. JPS Shop Made Fittings are mechanically welded on an XLT 2000 Splicing Table and conform to Corp of Engineers 03250 Installation Guide, July 1995. Shop Made Fittings exceed the specifications and present a cost effective alternative to field fabrications.

Call JP Specialties, Inc. for more information.

SPECIAL SAFETY NOTATION: When splicing PVC waterstop, inhalation of the fumes may be harmful to your health. Splicing should be done only in areas with adequate ventilation.

Waterstop Job Site Installation Guide551 Birch Street, Lake Elsinore, CA 92530Phone: (951)-674-6869 • (800) 821-3859 • FAX (951) 674-1315www.jpspecialties.com • [email protected]

revised 04/08

J P SPECIALTIES, INC.

Page 28: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

NOTA: Se recomienda que utilize la maquina que empalma JP Specialties, Inc. ST-10® Waterstop. Las direcciones siguientes son dirigidas sin usar la maquina ST-10. La maquina ST-10 realzara grandemente la calidad de la soldadura y reducira el tiempo usado para soldar.

FABRICACIONES DEL CAMPO: Lo que sigue es el procedimiento apropiado para el campo, segun lo recomendado por JP Specialties, Inc. que empalma waterstops que no contiene metales.

Propocionar las anas, las tes, las cruces, y las transiciones fabricadas hechas de los waterstops que 1. dejan solamente los empalmes rectos para el campo. Siempre corte las orillas cuadrada antes de soldar el waterstop. No se debe soldar con mucha fuerza para no dañar el material.

Utilizar una tabla de trabajo para crear los empalmes del campo. La tabla debe ser solida, tener 2. acceso a la fuente de alimentacion de 115 voltios, y tener plantillas y accesorios para ayudar a empalmar.

Cortar los extremos cuadrados, usar un cuchillo o una sierra circular equipada de una lamina in-3. clinada carburo (10" diametro con 40 dientes) para asegurar que los bordes queden parejos.

Precalentar la plancha, cubierta en Teflon (JP 214 or JP 414), a 350-380ºF para el PVC o a 410 to 4. 430ºF para TPER / TPV. Se recomienda verificar la temperatura con un termometro digital.

Colocar el hierro entre los extremos. Mantener el waterstop en lugar hasta que un bordado de 5. aproximadamente 3/16" se forme en cada lado del waterstop. Quitar rapidamente la plancha que empalma y colocar los extremos del waterstop juntos hasta que enlacen (aproximadamente 3 a 5 minutos o se sienta fresco al tacto). El waterstop se puede rociar con agua fria para apresurar el enlace. No mover, no doblar, no estirar ni tensionar el empalme antes de que el tiempo reco-mendado enlace. Al soldar el TPER / TPV, si no se ensamblan los extremos rapidamente, el material derretido pelara encima, dando por resultado un enlace inadecuado.

Al fabricar el waterstop en tes horizontales, las anas o las cruces junten los extremos a un an-6. gulo de 45 grados para que se mantenga la continuidad de las costillas y/o el bulbo de centro. Esto producira un empalme mucho mas fuerte. Las medidas fabricadas en el almacen de JPS se sueldan mecanicamente en una tabla XLT 2000 que empalma y se ajusta a medida con las regulaciones de la Guia de la Corp de Ingenieros 03250 Julio1995. Los ajustes hechos en la fabrica an excidido las especificaciones y presenta una alternativa economicamente rasonable para las fabricaciones del campo de trabajo.

Contactar a JP Specialties, Inc. para mas informacion.

NOTACION ESPECIAL DE CUIDADO: Al empalmar el waterstop del PVC la inhalacion de los humos puede ser danosa a su salud. El empalmar se debe hacer solamente en areas con la ventilacion adecuada.

Guia de Instalacion de Waterstop551 Birch Street, Lake Elsinore, CA 92530Phone: (951)-674-6869 • (800) 821-3859 • FAX (951) 674-1315www.jpspecialties.com • [email protected]

revised 04/08

J P SPECIALTIES, INC.

Page 29: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

SECTION 1: PRODUCT AND COMPANY IDENTIFICATION

PRODUCT NAME: EARTH SHIELD® TPE - Rubber (aka TPV or Thermoplastic Vulcanizate) PRODUCT DESCRIPTION: Thermoplastic Elastomeric Rubber Waterstop

MANUFACTURER: JP Specialties, Inc. ADDRESS: 25811 Jefferson Ave Murrieta, CA 92562

EMERGENCY PHONE: 1-800-821-3859FAX PHONE: 1-951-763-7074

SECTION 2: HAZARDS IDENTIFICATION

ROUTES OF ENTRY:

EYES: Yes SKIN: Yes

INGESTION: Not probable INHALATION: Yes

HEALTH HAZARDS (Acute & Chronic): May form combustible dust concentrations in air during processing and/or handling. Contact with hot material presents thermal burn hazard. Dust may be irritating to the eyes and the respiratory tract. Elevated temperatures or mechanical action may form vapors, mists or fumes which may be irritating to the eyes and respiratory tract. SIGNS AND SYMPTOMS OF EXPOSURE: Dust may scratch eyes and cause minor irritation to the respiratory tract. When heated, the vapors/fumes released may cause respiratory tract irritation. MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: Not available

TOXICOLOGICAL DATA:

COMPONENT TEST RESULTS CARBON BLACK (1333-86-4) Certain carbon blacks have probed carcinogenic in animal studies. Inhalation animal studies of high concentrations resulted in chronic inflammation, lung fibrosis and lung tumors. Epidemiology studies of workers include findings of bronchitis, pneumonia, emphysema and excess cancer. Substances bound in a polymer or other matrix should present little or no hazard. Petroleum Wax Not carcinogenic in lifetime animal skin painting or oral feeding studies. Did not cause mutations in vitro. High oral doses in one rat strain (F-344) resulted in microscopic inflammatory changes (microgranulomas) in liver, spleen and lymph nodes, some increased organ weights, inflammation of the cardiac mitral valve, and accumulation of saturated mineral hydrocarbons in certain tissues. Non- sensitizing in animal tests and human subjects. Additives that are encapsulated in the polymer. Under the normal conditions for processing and use of this polymer the encapsulated additives are not expected to pose any health hazard. However, grinding of the polymer is not recommended without the use of appropriate measures to control exposure.

CARCINOGENICITY

This material is not considered to be hazardous according to regulatory guidelines. SECTION 3: FIRST AID MEASURES EYE CONTACT: Flush thoroughly with water. If irritation occurs, get medical assistance.

SKIN CONTACT: Wash contact areas with soap and water. For hot product: Immediately immerse in or flush affected area with large amounts of cold water to dissipate heat. Cover with clean cotton sheeting or gauze and get prompt medical attention.

MATERIAL SAFETY DATA SHEET FILE NO.: Earth Shield® TPE - Rubber MSDS DATE: 07/17/2013

PAGE 1 OF 5

Page 30: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

INHALATION: At ambient/normal handling temperatures, no adverse effects due to inhalation of dust are expected. In case of adverse exposure to vapors and/or aerosols formed at elevated temperatures, immediately remove the affected victim from exposure. Administer artificial respiration if breathing is stopped. Keep at rest.

INGESTION: First aid is normally not required. Seek medical attention if discomfort occurs. No adverse effects due to ingestion are expected. SECTION 4: FIRE-FIGHTING MEASURES

BOILING POINT: Not available PARTITION COEFFICIENT (N-OCTANOL/WATER): Not available

MELTING POINT: 175°C (347°F) - 230°C (446°F) DMSO EXTRACT (MINERAL OIL ONLY), IP 346: < 3 %wt

VAPOR PRESSURE (MM HG): Not available VAPOR DENSITY (AIR-1): Not available

SOLUBILITY IN WATER: Negligible EVAPORATION RATE (BuAc=1): Not available

AUTO IGNITION TEMPERATURE: Not available RELATIVE DENSITY (at 20°C): 0.9 - 1

VISCOSITY: Not available HYGROSCOPIC: Yes

FLASH POINT: Not available FREEZING POINT: Not determined

DECOMPOSITION TEMPERATURE: Not available

DENSITY: 900kg/m3 (7.51 lbs/gal, .09 kg/dm3) - 1000 kg/m3 (8.35 lbs/gal, 1 kg/dm3)

APPEARANCE AND ODOR: Black waterstop profile, rubber like odor, (odor threshold is not determined and pH is not available)

OTHER DATA: SPECIAL HAZARD DESIGNATIONS

H.M.I.S. RATING NFPA KEY HEALTH: 1 HEALTH: 1 0-MINIMAL FLAMMABILITY: 1 FLAMMABILITY: 1 1-SLIGHT PHYSICAL HAZARD: 1 INSTABILITY: 1 2-MODERATE PROTECTION: SPECIAL: 3-SERIOUS

FLAMMABLE LIMITS IN AIR, % BY VOLUME UEL UPPER: Not determined LEL LOWER: Not determined

EXTINGUISHING MEDIA: DO NOT use straight streams of water. Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

SPECIAL FIREFIGHTING PROCEDURES: Assure an extended cooling down period to prevent re-ignition. Evacuate area. Prevent runoff from fire control or dilution from entering streams, sewers or drinking water supply. Firefighters should use standard protective equipment and in enclosed spaces, self-contained breathing apparatus (SCBA). Use water spray to cool fire exposed surfaces and to protect personnel.

UNUSUAL FIRE AND EXPLOSION HAZARDS: Avoid generating dust as fine dust dispersed in air in sufficient concentration and in the presence of an ignition source is a potential dust explosion hazard. During fire, smoke, fumes, incomplete combustion products, oxides of carbon, formaldehyde, and flammable hydrocarbons may be formed.

NOTE: Physical and chemical properties are provided for safety, health and environmental considerations only and may not fully represent product specifications. Contact the Supplier for additional information.

SECTION 5: HANDLING AND STORAGE

PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE: Before using, read the product bulletin. Store in a cool, dry place. Keep container closed to prevent contamination.

STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: Review SECTION 4 FIREFIGHTING MEASURES and read the product bulletin before proceeding with clean up. Use appropriate personal protective equipment during clean up. Shovel or sweep up spills. Do not discharge into streams, ponds, lakes or sewers.

MATERIAL SAFETY DATA SHEET FILE NO.: Earth Shield® TPE - Rubber MSDS DATE: 07/17/2013

PAGE 2 OF 5

Page 31: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

WASTE DISPOSAL: Preferred options for disposal are recycling, incineration with energy recovery, and landfill. The high fuel value of this product makes incineration very desirable for material that cannot be recycled. Treatment, storage, transportation, and disposal must be in accordance with applicable local, state/provincial, and federal regulations.

SECTION 6: EXPOSURE CONTROLS/PERSONAL PROTECTION

VENTILATION:

The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Control measures to consider: Adequate ventilation should be provided so that exposure limits are not exceeded. SPECIAL PRECAUTIONS: Should significant vapors/fumes be generated during thermal processing of this product, it is recommended that work stations be monitored for the presence of thermal degradation by-products which may evolve at elevated temperatures (for example, oxygenated components). Processors of this product should assure that adequate ventilation or other controls are used to control exposure. It is recommended that the current ACGIH-TLVs for thermal degradation by-products be observed. Contact your local sales representative for further information. It is recommended that all dust control equipment such as local exhaust ventilation and material transport systems involved in handling of this product are designed and maintained to minimize dust generation and accumulation. Ensure that dust handling systems (such as exhaust ducts, dust collectors, vessels and processing equipment) are designed to minimize the potential for dust ignition and prevent explosion propagation. For example, use explosion relief vents, an explosion suppression system or inert equipment internals. Additional examples of proper equipment include only appropriately classified electrical equipment and powered industrial trucks. LOCAL: N/A SPECIAL: N/AMECHANICAL: N/A OTHER: N/A

RESPIRATORY PROTECTION: A respiratory protection program that meets country requirements must be followed whenever workplace conditions warrant respirator use. Consult the respirator manufacturer to determine the appropriate type of equipment for a given application. Observe respirator use limitations specified by the manufacturer. Consult the OSHA respiratory protection information located at 29 CFR 1910.134. EYE/FACE PROTECTION: Wear safety glasses with side shields. Wear tightly fitted chemical splash goggles and a face shield when the possibility exists for eye and face contact due to spattering or splashing of molten material.

SKIN PROTECTION: If there is a potential for contact with hot/molten material, wear heat resistant clothing and footwear. WORK HYGIENIC PRACTICES: Do not get in eyes. Keep away from food an drink. Handle in accordance with good industrial hygiene and safety practice.

OTHER:

OCCUPATIONAL EXPOSURE LIMITS (Note: Exposure limits are not additive)

OSHA Z1 Components Type Value Form CARBON BLACK (1333-86-4) TWA 3.5 mg/m3

ACGIH Components Type Value Form CARBON BLACK (1333-86-4) TWA 3 mg/m3 Inhalable fraction Component Type Value Form PARAFFIN WAX (8002-74-2) TWA 2 mg/m3 Fume

Personal protective equipment selections vary based on potential exposure conditions such as applications, handling practices, concentration and ventilation. Information on the selection of protective equipment for use with this material, as provided above is based upon intended., normal usage. Comply with applicable environmental regulations limiting discharge to air, water and soil. Protect the environment by applying appropriate control measures to prevent or limit emissions. Limits/standards are shown for guidance only. Follow applicable regulations. SECTION 7: STABILITY AND REACTIVITY

CHEMICAL STABILITY: Material is stable under normal conditions

HAZARDOUS POLYMERIZATION: Will not occur

MATERIAL SAFETY DATA SHEET FILE NO.: Earth Shield® TPE - Rubber MSDS DATE: 07/17/2013

PAGE 3 OF 5

Page 32: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

CONDITIONS TO AVOID: Contact with incompatible materials. Avoid elevated temperatures for prolonged periods of time. Elevated temperatures. > 260°C (500°F)

MATERIALS TO AVOID: Strong oxidizers, Halogenated compounds, Phenolic resins, Acetal resins

HAZARDOUS DECOMPOSITIONS OR BY-PRODUCTS: Material does not decompose at ambient temperatures SECTION 8: DISPOSAL CONSIDERATIONS

WASTE DISPOSAL METHOD: The unused product, in our opinion, is not specifically listed by the EPA as a hazardous waste (40 CFR, Part 261D), nor is it formulated to contain materials which are listed as hazardous wastes. It does not exhibit the hazardous characteristics of ignitability, corrosivity or reactivity and is not formulated with contaminants as determined by the Toxicity Characteristic Leaching Procedure (TCLP). However, used product may be regulated. Suitable routes of disposable are supervised incineration, preferably with energy recovery, or appropriate recycling methods in accordance with applicable regulations and material characteristics at the time of disposal. Disposal recommendations are based on material as supplied. Disposal must be in accordance with current applicable laws and regulations and material characteristics at time of disposal. SECTION 9: OTHER INFORMATION

COMPONENTS CAS# Percent*CARBON BLACK 1333-86-4 0 - 6PARAFFIN WAX 8002-74-2 0 - 1.5

*All concentrations are by percent by weight unless material is a gas. Gas concentrations are in percent by volume. Note: The product may contain varying levels of additives such as slip and antiblocking agents, antioxidants and stabilizers. The substances in the above table are components of one or more, but not all product grades.

ECOLOGY

ECO-TOXICITY - This material is not expected to be harmful to aquatic organisms.

Persistence and degradability expected to be persistentMobility low solubility, floats, expected to migrate from water to land, expected to partition to sediment and wastewater solids

Note: Material contains additives that are encapsulated in the polymer. Under normal conditions of processing and use the encapsulated additives are expected to have very limited solubility in water and, as a result, are not expected to cause adverse effects in the aquatic environment.

TRANSPORT INFORMATION

DOT/TDG/IMDG/IATA

Not regulated for land, sea or air transport

REGULATORY INFORMATION

US Federal Regulations When used for its intended purposes, this material is not classified as hazardous in accordance with OSHA 29 CFR 1910.1200

TSCA This material complies with the national/regional chemical inventory requirements

EPCRA Section 302 This material contains no extremely hazardous substances.

CWA/OPA This material is not classified by CWA/OPA as a pollutant.

Superfund Amendments & Reauthorization Act of 1986 (SARA) Section 313 toxic release inventory No Section 311/312 reportable hazard No

The following ingredients are cited on the lists below:

MATERIAL SAFETY DATA SHEET FILE NO.: Earth Shield® TPE - Rubber MSDS DATE: 07/17/2013

PAGE 4 OF 5

Page 33: JP 678-6 TearWeb TPV Waterstop Product Data - BuildSite.com

COMPONENT CAS# LIST CITATIONS

CARBON BLACK 1333-86-4 IARC2B, ACGIH ALL, OSHA Z, CA P65 CARC, IL RTK, MN RTK, NJ RTK, PA RTK

MAGNESIUM OXIDE 1309-48-4 ACGIH ALL, OSHA Z, IL RTK, MN RTK, NJ RTK

PARAFFIN WAX 8002-74-2 ACGIH ALL, IL RTK, MN RTK, NJ RTK

ZINC OXIDE 1314-13-2 MI 293

DISCLAIMER:

The information and recommendations provided herein are believed to be accurate at the time of preparation obtained from sources believed to be reliable. JP Specialties, Inc., makes no warranty, expressed or implied, concerning this document or the accuracy of the information contained herein.

The information and recommendations contained herein are not intended to relieve the reader of responsibility to investigate and understand the laws, procedures, and regulations applicable to the readers enterprise, not to relieve the reader of responsibility to comply with laws applicable to the readers enterprise and place of business and to verify independently the information provided in this document as it may relate to the reader’s specific process or application.

This Material Safety Data Sheet supersedes all other previously dated sheets for this product.

End of Section