Journal of Micromechanics and Microengineering TOPICAL REVIEW MEMS-based platforms for mechanical manipulation and characterization of cells To cite this article: Peng Pan et al 2017 J. Micromech. Microeng. 27 123003 View the article online for updates and enhancements. Related content Physics of Cancer: Cellular stiffness and deformability C T Mierke - Nanonewton force-controlled manipulation of biological cells Keekyoung Kim, Xinyu Liu, Yong Zhang et al. - MEMS sensors and microsystems for cell mechanobiology Jagannathan Rajagopalan and M Taher A Saif - This content was downloaded from IP address 142.150.248.65 on 23/11/2017 at 02:35

Transcript of Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf ·...

Page 1: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Journal of Micromechanics and Microengineering

TOPICAL REVIEW

MEMS-based platforms for mechanicalmanipulation and characterization of cellsTo cite this article: Peng Pan et al 2017 J. Micromech. Microeng. 27 123003

 

View the article online for updates and enhancements.

Related contentPhysics of Cancer: Cellular stiffness anddeformabilityC T Mierke

-

Nanonewton force-controlled manipulationof biological cellsKeekyoung Kim, Xinyu Liu, Yong Zhang etal.

-

MEMS sensors and microsystems for cellmechanobiologyJagannathan Rajagopalan and M Taher ASaif

-

This content was downloaded from IP address 142.150.248.65 on 23/11/2017 at 02:35

Page 2: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

1 © 2017 IOP Publishing Ltd Printed in the UK

Journal of Micromechanics and Microengineering

P Pan et al

Printed in the UK

123003

JMMIEZ

© 2017 IOP Publishing Ltd

27

J. Micromech. Microeng.

JMM

10.1088/1361-6439/aa8f1d

12

Journal of Micromechanics and Microengineering

1. Introduction

In the past few decades, manipulation and characterization of biological cells have been a popular research topic at the boundaries of several disciplines such as micro and nanotech-nology, biomedical engineering, biology, and medicine [1]. Mechanical cell manipulation techniques, such as cell trans-fer, isolation, immobilization, and injection, have been widely used in many biological and medical applications such as single cell analysis [2], cell-based drug screening [3], in vitro fertilization [4], and transgenic animal production [5]. As cells

are fragile, high-resolution force sensors are needed in certain cell manipulation tasks to quantify micro- to nanonewton-level cellular forces and avoid any damage to the cells [6]. In addition, the measurement of cellular forces has also enabled mechanical characterization of the cells [7]. Other types of sensors could also be involved to measure the physical prop-erties of single cells such as mass, density, and traction force [8, 9]. These cellular characteristics can provide us with useful insights into the signalling and function of the cells [10, 11].

Microelectromechanical systems (MEMS) have been regarded as ideal tools for cell manipulation and characteriza-tion, because of their unique features such as size matching to single cells and capability of generating/measuring microscale

MEMS-based platforms for mechanical manipulation and characterization of cells

Peng Pan1,2, Wenhui Wang3,5 , Changhai Ru4,5, Yu Sun1,5 and Xinyu Liu1,5

1 Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario M5S 3G8, Canada2 Department of Mechanical Engineering, McGill University, Montreal, Quebec H3A 0C3, Canada3 State Key Laboratory of Precision Measurement Technology and Instrument, Department of Precision Instrument, Tsinghua University, Beijing 100084, People’s Republic of China4 Robotics and Microsystems Center, Soochow University, Suzhou, Jiangsu 215006, People’s Republic of China

E-mail: [email protected], [email protected], [email protected] and [email protected]

Received 26 June 2017, revised 13 September 2017Accepted for publication 26 September 2017Published 20 November 2017

AbstractMechanical manipulation and characterization of single cells are important experimental techniques in biological and medical research. Because of the microscale sizes and highly fragile structures of cells, conventional cell manipulation and characterization techniques are not accurate and/or efficient enough or even cannot meet the more and more demanding needs in different types of cell-based studies. To this end, novel microelectromechanical systems (MEMS)-based technologies have been developed to improve the accuracy, efficiency, and consistency of various cell manipulation and characterization tasks, and enable new types of cell research. This article summarizes existing MEMS-based platforms developed for cell mechanical manipulation and characterization, highlights their specific design considerations making them suitable for their designated tasks, and discuss their advantages and limitations. In closing, an outlook into future trends is also provided.

Keywords: microelectromechanical systems (MEMS), microfabricated devices, cell mechanical characterization, cell manipulation, single-cell analysis

(Some figures may appear in colour only in the online journal)

Topical Review

IOP

2017

1361-6439

5 Authors to whom any correspondence should be addressed.

1361-6439/17/123003+17$33.00

https://doi.org/10.1088/1361-6439/aa8f1dJ. Micromech. Microeng. 27 (2017) 123003 (17pp)

Page 3: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

2

motions and forces. MEMS sensors and actuators have characteristic feature sizes ranging from sub-micrometers to hundreds of micrometers, which are at the same level of the sizes of single cells. This perfect size matching makes it straightforward and convenient to adopt MEMS devices for cell manipulation and characterization. MEMS displacement and force sensors possess high resolution down to sub-nanom-eter and sub-nanonewton levels, respectively; thus, the small cell deformation and low cellular force can be accurately detected by on-chip sensors of MEMS-based platforms.

Despite its compact structure, a MEMS device may realize multiple functions (e.g. micrograsping, cellular force sensing, and cell deformation measurement) required in cell manipu-lation and characterization. In addition, materials commonly used for constructing MEMS devices (e.g. silicon, silicon diox-ide/nitride, and polymers) are biocompatible and thus impose little adverse biological effect on cells being manipulated. Moreover, the amenability of MEMS devices to batch fabrica-tion methods allows for manipulation and characterization of many cells in parallel, improving the manipulation/characteri-zation throughput and resulting in robust statistical data.

A variety of MEMS-based platforms have been developed for mechanical cell manipulation and characterization. Several review articles have been published focusing on MEMS-based devices for cellular force measurement and cell mechanobiol-ogy [8, 12–14]; however, there is no comprehensive review summarizing the application of MEMS-based platforms to all kinds of mechanical cell manipulation and characteriza-tion tasks. This article is aimed to bridge this gap to review the existing MEMS-based platforms for mechanical cell manipulation and characterization, and discuss their unique features suitable for certain types of cell manipulation/char-acterization tasks. We will not review microfluidic platforms for cell manipulation and characterization, which represent another category of widely used technologies. One can find several excellent reviews on this topic [15–18]. The follow-ing MEMS-based platforms will be discussed: (i) MEMS microgrippers for cell grasping, transfer and mechanical char-acterization; (ii) MEMS physical sensors for cellular force and mass/density measurement; (iii) MEMS-based devices for cell immobilization and patterning; and (iv) MEMS-based cell injectors. In closing, an outlook into future trends along this direction is provided.

2. MEMS microgrippers for cell grasping, transfer, and mechanical characterization

As one of the earliest developed MEMS end-effectors [19], MEMS microgrippers have been a popular tool for manipulat-ing micro-objects [20–22]. A MEMS microgripper can pick, transport, and place a cell in its culture medium; it can also integrate on-chip force sensors for quantifying and controlling the grasping force, thus avoid damage to the cell, and even characterize its mechanical property during manipulation. As biological cells are fragile and usually need to be manipulated in its aqueous culture medium, special considerations in the microgripper design are needed. In this section, we summarize

the existing MEMS microgrippers that have been applied to mechanical cell manipulation and characterization, and dis-cuss their specific designs and experimental conditions.

Based on the actuation method of their gripping arms, existing MEMS microgrippers for cell manipulation can be largely grouped into five categories. (i) Electrostatic micro-grippers. Electrostatic microgrippers are the first type of MEMS microgrippers reported in the literature [19], which involve electrostatic forces for driving their gripping arms and open/close their jaws. Electrostatic microgrippers share many advantages with electrostatic actuators such as high positioning resolution, fast response, low power consumption, and good compatibility with silicon microfabrication. For cell manipulation, the gripping jaws of an electrostatic microgrip-per do not have temperature elevation, and could, if properly configured, remain at zero electric potential during actuation; these features make it particularly suitable for interacting with cells. (ii) Electrothermal microgrippers. Electrothermal microgrippers rely on the thermal expansion of microstruc-tures to produce motions and actuate their gripping arms [21, 23]. The heat is usually generated by the Joule effect on conductive microstructures. Compared with electrostatic microgrippers, electrothermal microgrippers require smaller footprints for actuation, provide larger gripping forces, but have slower responses. Electrothermal microgrippers usually have one or two ‘hot’ gripping arms caused by heat transfer from their electrothermal actuators, and may induce thermal damage to cells during manipulation. Special management of the temperature elevation of the gripping arms is needed.

(iii) Magnetic microgrippers. Magnetic forces have been recently used for actuating MEMS microgrippers [26–28]. Different from electrothermal actuation, magnetic actuation does not produce heat and thus does not impose thermal impact on biological cells being manipulated. It produces relatively large actuation forces, and allows both on- and off-chip magn-etic sources (e.g. an electromagnet) to apply actuation. It can be used to manipulate cells in ionic liquids without special consideration of the device electrical design. (iv) Self-Folding Thermobiochemical Microgrippers. This type of microgrippers integrate multiple self-folding gripping arms and are driven by the differential stress or material swallowing in bilayer thin-film structures [25, 29, 30]. Their operations are typically triggered by changes in temperature or chemical environment, and thus called thermobiochemical microgrippers [30]. These are untethered and integrated with magnetic materials, allow-ing them to be controlled by an external magnetic field for cell transfer. (v) Pneumatic microgrippers. Pneumatic actuation has also been implemented in MEMS microgripper designs, in which deformable structures are actuated by pneumatic forces to open and close gripping arms [31, 32]. Pneumatic actua-tion can provide larger output forces (i.e. at the level of 10’s to 100’s mN) than other actuation mechanisms, and thus allow large displacements of the gripping arm tips. Table 1 summa-rizes the working principle, advantages, and disadvantages of the aforementioned five types of microgrippers.

All the five types of MEMS microgrippers have been applied to cell manipulation and characterization. We will review the previous work by categories, and will also discuss

J. Micromech. Microeng. 27 (2017) 123003

Page 4: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

3

the device design considerations specific for applications in cell manipulation and characterization. For more details of the actuation and sensing mechanisms in MEMS microgrippers, please refer to a recent review article [33].

2.1. Electrostatic microgrippers

Many electrostatic microgrippers have been developed to manipulate micro-objects [19, 20, 34–43], among which sev-eral have been applied to cell manipulation. Kim et  al [19] developed the first electrostatic microgripper with overhang-ing gripping arms through a surface micromachining process,

and an etch-stop technique was used to create the overhang-ing gripping arm structures. The device was demonstrated for grasping of red blood cells (RBCs) and micro-organisms. To measure the grasping force during cell manipulation, Beyeler et al [20] designed an electrostatic microgripper (figure 1(A)) with an on-chip integrated capacitive force sensor. A lateral comb-drive microactuator was used to drive the active arm, and an transverse-comb differential capacitive force sensor was attached to the passive arm for grasping force measure-ment. The device was fabricated through a customized silicon-on-insulator (SOI) microfabrication process. To allow this microgripper to operate in aqueous solutions, the active

Table 1. Summary of the five types of MEMS microgrippers.

Microgripper type Actuation principle Advantages Disadvantages

Electrostatic microgripper

Electrostatic force High positioning resolution; fast response; low power consumption; good compatibility with silicon microfabrication

Long gripping arms; large footprint for actuation; low gripping force; challenging

Electrothermal microgripper

Thermal expansion of microstructures

Small footprint for actuation; large gripping force; large displacement

Slow response elevation at gripping arms

Magnetic microgripper

Magnetic force No temperature elevation; relatively large gripping force; no limitation in liquid environment

Hysteresis

Self-folding thermobiochemical microgripper

Stress mismatch or material swallowing induced deformation of microstructures

Untethered; movable by magnetic field; parallel operation of many microgrippers

Inability to control grasping force and displacement

Pneumatic microgrippers

Pneumatic force Large gripping force and output displacement Relatively complicated fabrication

Figure 1. MEMS microgrippers with different actuation mechanisms for cell manipulation and characterization. (A) An electrostatic microgripper with a comb-drive actuator and transverse-comb differential capacitive force sensor. © [2007] IEEE. Reprinted, with permission, from [20]. (B) An electrothermal microgripper fabricated from SU-8 photoresist with the areas of U-beam electrothermal actuators coated with thin-film metal heaters. © [2005] IEEE. Reprinted, with permission, from [23]. (C) An untethered microgripper actuated by magnetically programmable composite materials patterned on its gripping arms. © [2017] IEEE. Reprinted, with permission, from [24]. (D) An untethered microgripper actuated by a swellable polymer layer sensitive to temperature change or chemical. Reprinted with permission from [25]. Copyright (2015) American Chemical Society.

J. Micromech. Microeng. 27 (2017) 123003

Page 5: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

4

and passive gripping tips were electrically isolated with the comb-drive actuator and the capacitive force sensor, respec-tively, by etching through the device layer of the gripping arms with electrical-isolation trenches while using the handle layer of the SOI wafer underneath the trenches for mechanical connection. This microgripper can grasp micro-objects with sizes up to 100 µm with a force measurement resolution down to 70 nN. Glass micro-beads and HeLa cells were picked and placed using this gripper, and the measured grasping force could be monitored to avoid cell damage during manipula-tion. An updated version of the microgripper design was later reported by Muntwyler et al [44], which was used to charac-terize the mechanical properties of plant cells. Although the on-chip force sensors of these microgrippers could enable force-controlled micrograsping, no such experiment was dem-onstrated in [20, 44].

Apart from linear electrostatic actuators, rotatory elec-trostatic actuators have also been used to actuate MEMS microgrippers for cells manipulation [45]. In this work, each rotatory electrostatic actuator includes two sets of curved, interdigitated fingers, one of which are fixed and the other are suspended by flexures. A novel electrothermal force sen-sor was developed and integrated with this microgripper. This microgripper can achieve a stroke of 90 µm between two grip-ping tips and a gripping force measurement range of 17 µN. This microgripper was used to manipulate Lilium pollen cells and measure the cell’s bursting point of gripping force to be 8.7 µN. Although the electrothermal force sensor provides a relatively high sensitivity, the heater it involves operates at 786 °C, which could induce a hot passive gripping tip and thus cause adverse impact on a cell being grasped. This work did not measure the temperature of the passive tip during operation.

One should note that the sensors and actuators in the elec-trostatic microgrippers usually cannot operate in aqueous solutions. Therefore, to make an electrostatic microgripper capable of manipulating cells in solutions, its gripping arms are usually designed long enough to be immersed into a solu-tion while keeping its base with the microactuator and force sensor outside. However, long gripping arms could lead to low loading capability and obvious out-of-plane motions of the gripping tips [23].

2.2. Electrothermal microgrippers

Electrothermal microgrippers represent another popular type of microgripper designs [21, 23, 46–58]. In terms of actuator design, four types of electrothermal actuators have been used.

2.2.1. Microgrippers with U-beam electrothermal actua-tors. A U-beam actuator includes a ‘hot’ arm and a ‘cold’ arm connected in a U shape [23, 50–52]. These two arms will have different levels of thermal expansion once electric cur-rent passes through them, because their different resistance levels cause different levels of Joule heating and thermal expansion in the two arms. This eventually induces a bending

motion of the U-beam actuator. Chronis et al [23] developed a polymeric microgripper with two active gripping arms driven by U-beam electrothermal actuators (figure 1(B)). The device was fabricated from SU-8 photoresist and thin-film metals (Cr/Au) through surface micromachining. The Cr/Au layer was embedded in the SU-8 U-beam actuators to form heating resistors. As SU-8 has a higher coefficient of thermal expan-sion (552 ppm °C−1) than silicon and metals, the device can be operated under low actuation voltages (1–2 V) and at relatively low temperatures (⩽32 °C). In addition, the SU-8 gripping arms are insulative, and thus can be directly immersed into aqueous ionic solutions for cell manipulation. This device can grasp cells with a diameter up to 10 µm, and was used to pick and place Hela cells in solution. Using a similar microfab-rication process, a bidirectional electrothermal microgripper was developed by Solano et al [50]. By arranging the heating elements asymmetrically, the device can realize bidirectional motions of one gripping tip to open and close the gripper tips. The device was applied for manipulation of mouse oocytes.

2.2.2. Microgrippers with V-beam electrothermal actua-tors. Although U-beam actuators can provide sufficient actuation performance for microgrippers, they are usually limited to small operation strokes at the gripping tips. To get large operation displacements, many MEMS microgrippers have involved V-beam electrothermal actuators and motion amplification mechanisms [21, 53, 54]. Colinjivadi et al [53] developed a MEMS microgripper with a V-beam actuator and a lever mechanism for motion amplification, which is capable of grasping cells with a size range of 15–50 µm. It was demonstrated for manipulation of rat kidney cells in solu-tion. The long gripping arms of this device limit the temper-ature elevation at its gripping tips and thus reduce the thermal impact on the target cell. Finite element simulation was used to predict the temperature elevation of the gripping tips, but no exper imental measurement was performed to validate the prediction. In another microgripper design [52], a jointless compliant mechanism was used to amplify output motions of a V-beam actuator to achieve a large stroke of gripping tips. The device was used to manipulate bacterial cells.

Kim et al [21] proposed a microgripper design involving a V-beam actuator and two-axis differential capacitive force sensors, which was used to perform force-controlled grasp-ing of interstitial cells. The two-axis force sensors, attached to the passive gripping arm, can detect the contact force, along the gripping arm direction, between the passive grip-ping tip and the target cell or device substrate (resolution: 38.5 nN), and thus avoid damage of the cell or the micro-gripper; it can also be used to measure the grasping force (resolution: 19.9 nN). A closed-loop force controller was established to regulate the grasping force with a resolution of 20 nN. Using a fine-gauge thermocouple, the temperature of the ‘hot’ active gripping tip was characterized to be within 29 °C during cell manipulation.

2.2.3. Microgrippers with Z-beam electrothermal actua-tors. Due to their inclined beams, V-beam electrothermal

J. Micromech. Microeng. 27 (2017) 123003

Page 6: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

5

actuators provide limited output displacements. To obtain larger output motions, Zhu et al [59] developed a new type of electrothermal actuator called Z-beam electrothermal actua-tor. This design is similar to the V-beam actuator except using Z-shaped beams instead of V-shaped beams. The Z-beam actuator has smaller stiffness along its output motion direc-tion, and, thus can act as a simultaneous load sensor [60]. Based on this low-stiffness characteristic, a new bidirectional electrothermal actuator was developed, in which two flexible Z-shaped beams are connected back to back to actuate the device bidirectionally [61]. The dynamic range of this new Z-beam actuator is exper imentally demonstrated to be more than 20 µm. Yang and Xu [62] proposed a conceptual design of a MEMS microgripper consisting of a Z-beam electrother-mal actuator and an electrothermal force sensor. Simulations were performed to show that this microgripper can provide a large grasping range of 80 µm at a low input voltage of 6 V. Microgrippers with Z-beam electrothermal actuators have not been applied to cell manipulation.

2.2.4. Microgrippers with out-of-plane electrothermal actua-tors. Besides U-beam and V-beam actuators that generate in-plane motions, out-of-plane electrothermal actuators have also been used for microgripper actuation. Li and Xi devel-oped a tri-layer electrothermal actuator using Parylene C and thin-film metal to generate out-of-plane motions, and con-structed a six-finger microgripper actuated by electrical cur-rent or temperature [56, 63]. Because of the excellent thermal insulation property and high coefficient of thermal expansion of Parylene C, the tri-layer electrothermal actuator requires a low actuation power and produces large out-of-plane dis-placements. The microgripper was applied to grasping crab eggs with a diameter of ~1 mm.

A critical issue of using electrothermal microgrippers for cell manipulation is the thermal management of electrothermal actu-ators. It is always desired to minimize the temperature elevation at the active gripping tips and thus avoid any adverse impact on cells. Common practices are to add heat sinks to the electrother-mal actuator [21, 64], and create thermal isolation trenches in the ‘hot’ gripping arm(s) when a SOI microfabrication process is used [21]. For the method of adding heat sinks, Qin and Zhu [65] conducted a combined exper imental and modelling study on the effect of heat sink beams on the temperature distribution of a V-beam actuator, providing useful guidelines on the design of heat-sink beams to achieve both low temperature elevation and large output displacement of the actuator.

2.3. Magnetic microgrippers

Some researchers have utilized magnetic force to actuate a microgripper [24, 28, 66]. Ger et  al developed a microfab-ricated magnetic microgripper for on-chip cell manipulation [28]. Each of the two gripping arms of this device consists of a zigzag structure with tapered anisotropic magnetic films deposited on them. When an external magnetic field is applied by an electromagnet, the zigzag structures experience in-plane torques and drive two the gripping tips to change their gap. This microgripper can manipulate micro-objects of 22–42

µm, and was employed for grasping single human neural progenitor cells [28]. The device allows for off-chip, remote magnetic actuation; however, it suffers hysteresis in actuation because of magnetization reversal of the zigzag structures.

Zhang et al [24, 67] developed the first untethered magn-etic microgripper (figure 1(C)) with four gripping arms made from a magnetically programmable composite material, which can be directly actuated and controlled by magnetic forces and torques. The four gripping arms can be reversibly controlled to grasp and release a micro-object, and the entire microgrip-per can also be moved and rotated in an aqueous solution by applying a magnetic gradient and a rotating magnetic field, respectively. Simple control strategies were proposed to dem-onstrate autonomous three-dimensional (3D) cell grasping and transfer [24].

2.4. Self-folding thermobiochemical microgrippers

Gracias and co-workers developed a new type of untethered self-folding microgrippers [25, 29, 30, 68], which are actuated by stress mismatch or material swelling in bilayer thin-films of their gripping arms and triggered by signals such as temper-ature change and chemical treatment. A review on this type of self-folding devices can be found in [69].

The simplest design in this type of microgrippers was pro-posed by Malachowski et al [29] to capture single cells, which has the potential for both in vitro and in vivo applications. This microgripper is composed of four differentially-stressed SiO/SiO2 bilayer arms with rigid segments (patterned on their surfaces), serving as arm joints. Its operation is initiated by the release of the planar gripping arms from their substrate, during which single cells (fibroblast and RBC) on top of the device are captured. The size and folding radius of the grip-ping arm are tailored to match the size of the target cell type. The SiO/SiO2 arms are transparent, and the cell encapsulated within the microgripper can be observed under a microscope.

Leong et  al [30] proposed a more complex design that includes a differentially-stressed metallic bilayer (Cr/Cu) for device actuation, a patterned rigid Ni layer for forming self-fold-ing joints of the gripping arms, and patterned polymer segments on the folding joints for triggering the self-folding. When heated or treated with a chemical, the polymer segments become less rigid and thus allow the gripping arm to fold and release the stresses in the Cr/Cu bilayer. The Ni layer also permits the microgripper to be guided to designated positions by a mobile magnet. Capture and transfer of a living cell mass were demon-strated, and the cell viability after manipulation were verified. The closed form of this microgripper is ~5–20 times larger than typical mammalian cells [30], and thus cannot capture single cells. Another drawback of this design is that the microgripper, once closed, cannot re-open for cargo release. Using a swella-ble hydrogel (pNIPAM-AAc) as both actuation and triggering material, Breger et al [25] developed a self-folding microgrip-per capable of reversibly folding and unfolding. The device is responsible to a change in temper ature around body temperature (~36 °C), promising potential in vivo applications.

Compared with other kinds of microgrippers, unteth-ered microgrippers can capture cells in many places where

J. Micromech. Microeng. 27 (2017) 123003

Page 7: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

6

it is hard to reach by conventional microgrippers. This kind of microgrippers can also manipulate cells or tissues in vivo and be controlled by a magnetic resonance imaging facility. In terms of the triggering signal, the body temperature (36– 37 °C) could be a turning point for the device to operate, and other types of signals such as pH and physiologically-relevant chemicals are also possible options as a variety of stimuli-responsive materials are available [70]. As an untethered microgripper fabricated with ferromagnetic material can be simultaneously imaged and controlled by a magnetic reso-nance imaging facility, it can be also loaded with live cells (e.g. through encapsulation in hydrogels) and serve as a vehi-cle for in vivo tissue repairing and/or drug delivery. Due to their unique capability of remote grasping and manoeuvering, the self-folding thermobiochemical microgrippers hold great potential in biological and medical research and practices.

2.5. Pneumatic microgrippers

Bütefisch et  al [32, 71] reports the first pneumatic MEMS microgripper. The device operation is based on two pneumatic microactuators, each of which includes a flexure-tethered piston actuated by pressurization. The two pneumatic microactua-tors are connected to the gripping tips through flexure-hinged beams, and are configured open and close the gripping tips, respectively. The microgripper structures were fabricated from either silicon or SU-8 photoresist. It was demonstrated that the SU-8 structures provide lower compliance and thus higher out-put displacements at the gripping tips, and can be fabricated using a relatively straightforward photolithography process [71]. The microgripper was applied to grasp micrometer-sized gears, but no cell manipulation was demonstrated.

Kim and co-workers developed a pneumatically actu-ated MEMS microcage [31]. The microcage is a spherical microcontainer formed by curved aluminum cantilevers (i.e. microgripper fingers), and is normally closed without pneu-matic actuation. The anchors of the curved cantilevers are arranged on top of a suspended thin membrane of SiO2/Si3N4, which can be bulged through pressurization of the pneumatic chamber underneath it. The bulging of the thin membrane tilts the curved cantilevers and open up the microcage for grasp-ing. This device was used for grasping of live microbes with a size of ~400 µm. The microcage is ~900 µm in diameter, and thus cannot be directly applied to manipulate small mam-malian cells (5–20 µm in diameter). Further miniaturizing the microcage design is possible, but challenges in microfabrica-tion may arise.

3. MEMS physical sensors for cell manipulation and characterization

In cell manipulation, a variety of physical signals, such as cellular force, mass, and density, can be measured. This sec-tion will discuss existing MEMS physical sensors applied to cell manipulation and characterization, and will be organized by the type of physical measurement conducted by the MEMS devices. Table 2.

3.1. Measuring interaction forces during cell injection

Mechanical cell injection is a typical technique widely used in biological and medical research such as genetics, develop-ment, drug discovery, and assisted reproductive technology (ART). In this technique, a glass micropipette is used to penetrate an adhesive or suspended cell and deliever foreign materials into a desired location inside the cell. As cells are fragile and prone to damage, it is highly desired to monitor the injection process through various feedback modalities. Besides the most straightforward visual feedback from a microscope, the interaction force between the micropiette and the target cell could provide critical information of the injec-tion process and potentially avoid unnecessary mechanical impact on the cell.

Due to their high accuracy and sensitivity, many MEMS force sensors have been developed for quantifying interac-tion forces during cell injection. Micro force sensors based on a piezoelectric polymer, polyvinylidene fluoride (PVDF), have been developed and applied to injection force meas-urement [56, 72, 73]. This type of device was integrated into robotic cell injection systems for prediction of the cell membrane pentration and closed-loop control of the injec-tion force [74, 75]. The resolution of PVDF-based force sensors can reach sub-micronewton level. Because of the inherent characteristic of piezoelectric sensing, these sen-sors are more suitable for dynamic force sensing than static measurement.

Zhang et al [76] proposed an uniaxial MEMS force sen-sor based on diffractive optical encoders fabricated from Si3N4. This force sensor consists of a pair of transmission phase microgratings (index and scale gratings) with the same constant pitch, and a cell injection probe linked to the index grating. An injection force exerted to the probe tip will lead to a relative displacement between the index and scale gratings and thus a change in the diffraction efficiency of the phase gratings, from which the relative displacement between the two gratings (thus the injection force) can be calculated by the intensities in the diffraction orders. This sensor was used to quantify injection forces of Drosophila embryos. This sen-sor requires a relatively sophisticated and bulky optical setup for signal readout. Liu et al [6, 77] employed microfabricated polydimethylsiloxane (PDMS) posts for real-time measure-ment of injection forces during robotic injection of zebrafish embryos and mouse oocytes. The key idea is to visually track deflections of PDMS posts supporting an embryo being injected, from which the injection force can be calculated through a mechanical model describing the injection force transmission and induced post deflection. The stiffness of the post determines the force measurement range and resolution, and can be tuned by adjusting the post’s dimensions (diameter and height) and Young’s modulus.

Multi-axis MEMS force sensors are useful for measuring both the normal injection force and the tangential force between the injection probe and the cell. Sun et al developed a two-axis transverse-comb differential capacitive force sensor [80]. The high aspect ratio of the comb fingers results in high resolution and sensitivity of the sensor. This device (figure 2(A)) was used

J. Micromech. Microeng. 27 (2017) 123003

Page 8: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

7

to measure the injection force of mouse embryos and thus char-acterize the mechanical properties of the embryo membrane (zona pellucida) [7]. The tangential force measured during embryo injection can also be quantified by the sensor for align-ment of the injection probe with the embryo center. Sieber et al [81] designed a three-axis piezoresitive force sensor. The sensor was mounted on a three-degree-of-freedom (3-DOF) nanoma-nipulator with a haptic interface, thus allowing bilateral cell manipulation with triaxial force feedback. The exper imental setup was demonstrated for interaction force measurements during palpation and injection of salmon fish eggs.

3.2. Studying cell mechanics and mechanotransduction

Forces generated by cells during interactions with their surrounding extracellular matrix (ECM) affect the cells’ functions such as signalling, migration, proliferation, and

differentiation [10, 82, 83]. On the other hand, when external forces are exerted on cells, their behaviours will also change [8]. Therefore, it is important to precisely measure forces gen-erated by cells and understand how cells respond to external forces. In addition, it is well accepted that the cell mechanical properties could serve as useful indicators for conditions of the cells. Abnormal or diseased cells, such as cancer cells or red blood cells infected with malaria parasites, are mechani-cally different from their normal counterparts [84–86]; cells at different developmental stages also reveal different elastic or viscoelastic properties [87]. Correlating a cell’s mechani-cal properties with its biological conditions could shed light onto cell development and provide new diagnostic tools. Due to the small sizes of cells, conventional large-sized force sen-sors are not suitable for cellular force measurement and cell mechancial chracterization. In contrast, MEMS force sensors have been widely adopted for these studies.

Table 2. Summary of MEMS physical sensors.

Sensor typeWorking principle Range Resolution Applications Examples Notes

PVDF based force sensor

Piezoelectric effect

µN–mN sub-µN Measuring cell injection force

[54, 70, 72] Suitable for dynamic force sensing; high linearity; high signal-to-noise (S/N) ratio; cannot work in high temperature environment

Micrograting based force sensor

Diffraction efficiency change

µN N/A Measuring cell injection force

[73] High resonant frequency; difficult to fabricate; sophisticated and bulky optical setup

PDMS posts based force sensor

Deflection of PDMS posts

µN–mN nN Measuring cell injection force

[6, 74] Easy to manufacture; can be used to investigate characteristics of different types of cells

Capacitive force sensor

Capacitance change

µN nN–µN Measuring cell injection force and characterizing cell mechanics

[7, 77] High resolution and sensitivity; large dimension; complicated circuit

Piezoresistive force sensor

Resistance change

mN–N nN–µN Measuring cell injection and palpation force

[78] High resolution and sensitivity; simple material; high bandwidth; Sensitive to temperature

Cantilever based force sensor

Deflection of beam

nN–µN nN Measuring cell traction force

[98, 99] Easy to manufacture; relying on visual measurement of structural deformation;

PDMS micropost array based force sensor

Deflection of micropost array

nN nN Measuring local cell traction force along arbitrary in-plane directions

[75] Simple mechanical model; popular in cell studies

Cantilever based force sensor with indentation probe

Deflection of beam

µN nN–pN Probing cellular response to extracellular forces

[76, 115–117] Simple structure; high resolution; capable of studying force responses of cells under large deformation

Cantilever based force sensor with two suspended semi-circular plates

Deflection of beam

µN N/A Probing cellular response to extracellular forces

[120] Semi-transparent cell culture plates enabling simultaneous cell stretching and fluorescence imaging

Cantilever based MEMS resonator

Shift in the resonant frequency of cantilever

N/A sub-femtogram

Measuring mass and density of single cells

[129] Able to weigh a single cell mass; mass resolution relies on quality factor

Four tethering beams based MEMS resonator

Shift in the resonant frequency of cantilever

Picogram N/A Measuring mass of adherent cells

[124] Uniform mass sensitivity irrespective of the cell position on the sensor

J. Micromech. Microeng. 27 (2017) 123003

Page 9: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

8

3.2.1. Characterizing cell mechanical properties. To charac-terize mechanical properties of a single cell, the cell needs to be deformed and the force-deformation data need to be accu-rately measured. Many of the force sensors we reviewed for injection force measurement (section 3.1) have also been used to quantify the mechanical properties of various cell types such as zebrafish embryos [73], mouse embryos [7] and oocytes [88, 89]. There are also other types of MEMS force sensors solely developed for characterizing cell mechanical proper-ties. For instance, a surface-micromachined cell squeezer was recently developed for characterize the stiffness and rupture mechanics of different strains of baker yeast cells [90]. A two-axis capacitive force sensor was also developed and integrated into a micromanipulation system for quantifying mechanical properties of plant cells [91].

Besides MEMS force sensor development, there are also two additional key components required for mechanical char-acterization of single cells. First, the cell deformation induced by a MEMS force sensor needs to be accurately measured to establish force-deformation curves. Under high-magnification optical microscopy, the cell deformation can be measured with a resolution down to the sub-micrometer level. Computer vision algorithms have also been developed for tracking the deformed membrane contour of a mouse embryo during MEMS-based mechanical characterization [92]. Secondly, based on the loading condition of the target cell, a specific mechanical model needs to be developed to extract the desired mechanical properties

from the measured force-deformation data. Researchers have developed cell mechanics models suitable for different loading conductions such as parallel-plate compression [55] and point loading [7, 88]. Most of the existing cell mechanics models treat a cell as a homogenous solid [55, 88]; when the cell mem-brane property is of the major concern, mouse embryos can also be modelled as a spherical elastic shell (membrane) enclosing liquid (cytoplasm) [7]. To handle large cell deformations, a semi-analytical-numerical model was developed to describe the mechanics of mouse oocytes under point loading, and its effec-tiveness was confirmed experimentally [88].

3.2.2. Quantifying traction and contractile forces of adher-ent cells. When an adherent cell is cultured on a substrate, it will exert traction forces to the substrate through its adhe-sion sites [93]. It has been demonstrated that the mechani-cal properties of cell culture substrates affect cells’ ability to generate traction forces, and also their morphology, migra-tion, and cytoskeletal structure [10]. Thus, measuring traction forces of cells under culture will help us not only understand behaviours of cells, but also study the relationship between the mechanical properties of ECM and the cells’ signalling and functions. With the advent of MEMS technologies, sub-strate-cell interaction forces can be accurately quantified with high special resolution, which has led to an entire category of microfabricated force sensors for cellular traction/contractile force measurement. An comprehensive review on this topic

Figure 2. MEMS force sensors for cellular force measurement. (A) A two-axis capacitive force sensor used for measuring injection forces during robotic cell injection. © [2003] IEEE. Reprinted, with permission, from [7]. (B) A PDMS micropost device for measuring the traction force distribution of an adherent cell cultured on top of the microposts. Reproduced with permission from [78]. [Copyright (2003) National Academy]. (C) One-axis (left) and two-axis (right) MEMS force sensors for studying the response of adherent cells to extracellular forces. Reprinted from [79], Copyright (2007), with permission from Elsevier.

J. Micromech. Microeng. 27 (2017) 123003

Page 10: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

9

was recently published by Polacheck and Chen [94], and we will discuss some typical device designs here.

The first platform for measuring cellular traction forces is developed by Harris et al [95]. A thin layer of silicone elastomer was used to culture cells, and local deformations (wrinkles) of the silicone layer was used to indicate the distribution of cel-lular traction forces. To facilitate the measurement of the local deformations, fluorescent microbeads were embedded into the silicone substrate [96–98], and semi-infinite-space elasticity models were developed to calculate the traction force distribu-tion from the measured substrate deformations [99]. Further improvements were made by Balaban et al [100] by introduc-ing regular micropatterns into the elastomer substrate through soft lithography. This micropatterned substrate simplifies the calculation of the cellular traction forces.

Along a different path of technology development, MEMS force sensors were developed for measuring cellular traction forces [101, 102]. Using surface micromachining, Galbraith and Sheetz [101] fabricated an array of horizontally arranged cantilever beams serving as traction force sensors. Lin et  al [102] also developed a micromachined force sensor for quanti-fying traction forces of rat heart cells. Both designs [101, 102] rely on visual measurement of structural deformations to deter-mine the traction force exerted by a cell, and can only measure forces generated at one location of the cell and along one direc-tion. Researchers also cultured multiple cardiac myocytes on the surface of a PDMS cantilever, which will be bent up when the myocytes contract [103, 104]. The average stress exerted by the cells on the cantilever surface was determined by mechani-cal analysis of the cell-PMDS bilayer cantilever using Stoney’s equation  and finite element modelling. It was found that the stress exerted by the cardiac myocytes on a flat cantilever sur-face is less than that on a grooved canti lever surface [103].

To replicate the capability of deformable substrates for mapping the traction force distribution from a cell, Chen and co-workers [78] developed an PDMS micropost array made by soft lithography (figure 2(B)), on which cells can be cultured. Two-step replica moulding was used to replicate high-aspect-ratio microposts from a SU-8 template onto a PDMS substrate. The vertically aligned microposts serve as individual force sensors to quantify local traction forces along arbitrary in-plane directions, which were generated at different locations of a cell. To spatially pattern cellular adhesion sites, top surfaces of selected microposts were coated with fluorescently-labelled fibronectin through microcontact printing, and the remaining unprinted areas of the micropost array were coated with a pro-tein-repellent polymer (Pluronics F127). When a cell spreads across and attach to the microposts, its local traction forces will deflect the microposts whose top surfaces are attached to the cell. The deflection of each post can be tracked through fluorescence imaging to generate a traction force vector map of the cell. As the deflection of each micropost is independent of those of its neighbouring microposts, the calculation of local traction forces is straightforward.

Due to the simplicity and versatility of Chen’s micropost device, it was rapidly popularized for a variety of cell stud-ies, and different versions of the micropost devices were

proposed [105–108]. Petronis et al [106] fabricated ultrahigh-aspect-ratio silicon microposts by deep reactive ion etching (DRIE), and achieved high accuracy and spatial resolution of the traction force measurement. Zhao and Zhang [105, 109] employed DRIE-fabricated silicon templates for one-step replica molding of micropost arrays, and applied the device to simultaneous traction force measurement and orientation alignment of cardiac myocytes. Zhang and co-workers [110, 111] also investigated the viscoelastic modeling and material characterization of PDMS microposts with low aspect ratios, which improved the calculation accuracy of traction forces.

Ganz et al [107] coated the top surface of microposts with selective adhesion molecules to mimic cell-cell interactions. Some researchers demonstrated that different stiffness and density levels of microposts affect the adhesion and traction of cells cultured on them [112–115]. To study forces exerted by cells cultured in three-dimensional (3D) environments, Ghibaudo et al [116] cultured cells within a micropost array. Sniadecki et  al [117] embedded magnetic cobalt nanowires into selected microposts to make them reponsive to an exter-nal magnetic field. Controllable forces were then applied to a cell cultured on the microposts through a magetic field, and the traction force response of the cell was quantified. This design adds to the micropost device the capability of simulta-neous mechanical stimulation and traction force measurement on cells.

3.2.3. Probing cellular response to extracellular forces. Uncovering a cell’s response to extracellular forces are impor-tant for us to better understand the cellular functions and mechanotransduction mechanisms. To this end, many MEMS devices have been developed for this type of studies.

Saif and co-workers [79, 118–120] have developed a series of one- and two-axis MEMS force sensors for studying cellular responses to external forces. These sensors (figure 2(C)) usually consist of a probe for cell indentation/stretch-ing, and low-stiffness force sensing beams attached to the probe for detecting force responses of the cell under indenta-tion and stretching. For cell stretching tests, the probe was coated with fibronectin to create adhesion sites with cells. The total stiffness of the sensing beams was pre-calibrated, and the cellular force experienced by the probe was then determined by quanti fying the beam deflection underneath a microscope. The force measurement range is tunable by changing the beam stiffness, and the force resolution could be as low as 0.5 nN [118]. Another advantage of these sen-sors is their capability of studying force responses of cells under large deformation, which could be as high as 50 µm [119]. These force sensors have been used to examine the force responses of monkey kidney fibroblasts and their corre-sponding changes in cytoskeletal structures [79, 119, 121].

In order to measure cellular force response under large deformation with high resolution, Saif and co-workers [120] also proposed an improved sensor design with force sens-ing beams connected in series. With a measurement range of 1 µN, the resolution of this force sensor can reach down to 50 pN. To avoid damage of the ultra-compliant force sensing

J. Micromech. Microeng. 27 (2017) 123003

Page 11: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

10

beams caused by capillary forces during microfabrication and device use, this sensor was always immersed in liquids (etchants in microfabrication, water in storage, and cell cul-ture medium in use). This sensor was applied to an in vivo study on the effect of mechanical tension on vesicle clustering in the presynaptic terminal of the neuromuscular junction in Drosophila embryos [122].

Recently, Serrell et al [123] designed a surface-microma-chined MEMS tensometer for uniaxial stretching and force-deformation measurement of fibroblasts. The device cul-tures a cell bridging two suspended semi-circular plates, one of which is attached to an actuator and the other of which is connected with force sensing tethering beams. The actuator is driven by an off-chip micromanipulator to stretch the cell, and the corresponding cellular force is quantified by measuring the deflection of the force sensing beams. The cell stretching experiments showed a linear force-deformation relationship before the cell was detached from the semi-circular plates, and the force required to detach a cell was determined to be ~1.5 µN. A revised design of this tensometer was later reported to allow simultaneous cell streching and fluorecence imaging [124]. The key idea of this design is a new SOI-based micro-fabrication process that forms semi-transparent cell culture plates using thin-film Si3N4.

3.3. Measuring the mass and density of single cells

Direct measurement of the mass or density of single cells could elucidate the intrinsic mechanism for the coordination between cell cycle and growth, and also predict physiologi-cal states of a cell [125]. Conventional methods for cell mass measurement are population-based, and cannot provide the growth rates of individual cells. Thanks to the ultrahigh sen-sitivity of MEMS resonators, the quantification of single cell mass and density has been realized [126, 127, 130–132].

Although nanoelectromechanical systems (NEMS) resona-tors have been developed with ultrahigh resolution for mass detection [128, 129], their resonant structures are usually of sub-micrometer sizes and this mismatch to typical cell sizes make them unsuitable for cell mass measurement. Ilic et al developed the first MEMS oscillator for measuring the mass

of a single bacterial cell [126]. The oscillator is based on a compliant Si3N4 cantilever beam, whose surface is coated with an antibody monolayer to immobilize bacterial cells. The cantilever was activated by thermal noise and its vibration was detected optically. The attachment of a cell onto the cantilever will cause a shift in the resonant frequency of the cantilever, which can be used to calculate the mass of the attached cell. Note that the sensitivity of such a cantilever resonator depends on the position where the cell is attached to, and becomes the highest when the cell is attached to the tip of the cantilever. Experiments showed that this device can effectively measure the mass of a single Escherichia coli cell in air. The mass reso-lution of this sensor is relatively limited because it has a low quality factor (Q-factor) of 50 caused by air damping. When this kind of resonators operate in air or solution (where cell mass is usually measured), the viscous effect of medium sur-rounding the resonator significantly affects the mass sensing performance [130].

To eliminate the performance degradation caused by the damping effect of the resonator surrounding medium and in the meanwhile maintain cells alive, Manalis and co-workers [131, 132] fabricated an air-tight microfluidic channel inside a resonant cantilever beam and operated the resonant beam in an vacuum environment (figure 3(A)). This sensor is actuated electrostatically and provides a high Q-factor up to 15 000. It was experimentally confirmed that the damping of the reso-nator does not increase when filling the channel with water, and a sub-femtogram resolution was achieved on this device [132]. This mass sensor can also be used to determine the den-sity of a cell by measuring the mean resonant frequency shift when the cell is placed in two solutions with different densi-ties [131].

To circumvent the nonuniform mass sensitivity of cantile-ver resonators that is dependent on the loading position, Park et  al [127] proposed a MEMS resonant mass sensor with a unique pedestal design (figure 3(B)), which retains uniform mass sensitivity irrespective of the cell position on the sensor. A central cell-carrying platform tethered by four beams was designed to minimize the variation (<4%) of the vibration amplitude of the central platform caused by the cell position change on the platform. An array of resonant mass sensors

Figure 3. MEMS-based resonators for mass and density measurements of single cells. (A) A cantilever resonator embedded with a microfluidic channel through which a cell is passed for mass measurement. Reprinted by permission from Macmillan Publishers Ltd: [NATURE] [132], Copyright (2007). (B) A MEMS resonator with four tethering beams that has uniform mass sensitivity on the central weighing platform. Reproduced with permission from[127].

J. Micromech. Microeng. 27 (2017) 123003

Page 12: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

11

was constructed through a SOI process, and used for batch growth and mass measurement of individual adherent cells for >50 h. To account for the cell-elasticity-induced vibration amplitude/phase differences between the central platform and the cell, an improved 2-DOF dynamic model of the resonant sensor was also proposed to estimate the ratio of the measured apparent mass to the actual mass of the cell. Using this sensor, the growth rate of human colon epithelial cells was measured to be approximately linear with an average of 3.25% h−1.

4. MEMS-based devices for single cell patterning and immobilization

In many applications like cell injection and mechanical char-acterization, target cells need to be positioned into a regular pattern and sometimes immobilized. Many microfabricated devices have been devised for patterning and immobilization of single cells based on different mechanisms [6, 7, 133–140].

Several devices rely on mechanical confinement to pattern single cells. Rettig and Folch [134] developed PDMS microw-ell arrays (figure 4(A)) for large-area single cell patterning, and achieved a single cell capture rate up to >90% by optimizing the microwell dimensions based on the cell type. Liu et al [6, 77] constructed PDMS cell holding devices serving two pur-poses: (i) to hold single zebrafish embryos and mouse zygotes in microwells for robotic cell injection, and (ii) to measure injec-tion forces through vision-based force measurement (whose mech anism has been discussed in section  3.1). Leveraging surface micromachining, Teichert et al [133] fabricated novel MEMS spatial mechanisms for immobilizing single cells. Two symmetric cylindrical mechanisms were actuated by a single slider to form a cell trap. The two mechanisms can realize self-centering of the cell and provide a firm hold after immobi-lization. However, this device is less practical for repeated use in cell studies since the surface-micromachined mech anisms are prone to wear and damage by structure stiction.

Other devices utilized vacuum (negative pressure) to cap-ture/immobilize cells [135–138]. Lee and co-workers [136, 137] used hydrodynamic suction forces to capture single cells; and employed this mechanism to perform single cell

electroporation [137] or bring multiple pairs of cells in con-tact for cell-cell communication studies [136]. Liu and Sun [135] fabricated a glass device (figure 4(B)) through wet etch-ing and used it for vacuum-based immobilization of mouse zygotes, which greatly enhanced the throughput of robotic mouse zygote injection. A revised design of this device was later realized by Lu et al [4] through injection molding, elimi-nating the need for microfabrication and allowing for device mass production. Park et al [138] developed a microfabricated cell processor capable of not only immobilizing a mouse embryo through vacuum suction but also controlling its orien-tation using dielectrophoresis (DEP).

Researchers also employed magnetic force to capture cells [139, 140]. Lee et al [140] designed a custom-made CMOS chip with an array of micro-electromagnets, which could gen-erate microscale magnetic field patterns to capture and transfer cells tagged with magnetic beads. Rajapaksha et al [139] also developed a MEMS device including micro-electromagnets for capturing rare circulating tumour cells (CTCs) that have been labelled with magnetic beads. Proof-of-concept experi-ments were performed using human breast tumor cells, and a capture efficiency of 95.2% was achieved.

5. MEMS-based cell injectors

Cell injection is usually performed using a glass micropipette loaded with injection materials, and automated robotic sys-tems have been developed to improve the injection accuracy, consistency, and throughput [3, 75, 141]. Researchers also developed MEMS-based cell injectors aiming at parallel cell injection or improved post-injection cell survival.

Microneedle arrays with solid or hollow structures have been fabricated using a variety of microfabrication processes [142–146], and successfully employed to introduce different biological materials into skins, tissues, and single cells. Using a microneedle array as the cell injector allows for parallel injection of many cells, thus providing a higher throughput than the conventional technique with a glass micropipette. For cell injection, the tip of a microneedle needs to match the size of the cell type to be injected.

Figure 4. MEMS devices for patterning and immobilization of single cells. (A) A PDMS device with microwells for single cell patterning. Reprinted with permission from [134]. Copyright (2005) American Chemical Society. (B) A glass device capable of immobilizing mouse zygotes for robotic cell injection. [135] (2009) (© Springer Science+Business Media, LLC 2009). With permission of Springer.

J. Micromech. Microeng. 27 (2017) 123003

Page 13: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

12

Several microneedle arrays have been designed specifi-cally for parallel cell injection. Trimmer et al [142] fabricated an array of pyramid-shaped silicon microneedles through a single-mask process, and used it to penetrate plant cells and deliver DNA solutions. The diameter of these microneedles is smaller than 0.1 µm. The microneedle array was also used to inject DNA into the gonad of the nematode worm C. elegans, with 8% of the first-generation descendants of the injected worms expressing the injected DNA [142, 143]. Although this kind of microneedle is simple to fabricate, the less-controlled injection process led to a relatively low success rate of injec-tion. To improve the cell viability after penetration, Teichert et al [144] fabricated arrays of high-aspect-ratio microneedles through a three-step DRIE process, and designed a compli-ant suspension mechanism to restrain rotations or transverse motions of the microneedles during cell injection and thus avoid tearing of the cell membranes. Thousands of HeLa cells were injected with high survival and injection success rates of 97.7% and 97.9%, respectively.

Both microneedle designs discussed above [142, 144] adopt solid structures without solution-delivering channels, and the biological materials to be delivered can only be either coated on the microneedle surfaces or placed in the culture medium surrounding the cells for delivery after cell penetration. The volume of materials delivered to a cell is uncontrollable. In order to precisely control the injection volume, Chun et  al [147] fabricated a hollow microneedle array, and also proposed an experimental setup for parallel cell injection (figure 5(A)). The setup includes a vacuum-based device for immobilization of many cells into a regular pattern, and a hollow micronee-dle array with a pitch aligned with the immobilized cell grid. Although this proposed setup is promising for efficient paral-lel cell injection, no injection experiments were conducted to test its effectiveness. Ichiki et al [148] fabricated an array of glass hollow microneedles through surface micromachining, and integrated it inside a microfluidic channel for injection of RBCs. These microneedles are horizontally anchored on a

substrate, and a single cell was moved toward a needle using optical trapping for penetration.

Besides the development of microneedle arrays as cell injectors, there are also integrated cell injection systems completely realized on micro-chips [149, 150]. Adamo and Jensen [150] developed a cell injection system on a micro-fluidic device, where a glass micropipette was integrated at the end of a cell delivery channel with its tip exposed inside the channel. When a cell is transported to the end of the channel, it will hit the exposed micropipette tip and get penetrated for mat erial delivery. The microfluidic device can continously deliver single cells to the micropipette tip and transport the injected cells to the downstream for collec-tion. This design provides a new way to realize automated cell injection. Aten et  al [149] developed a MEMS-based platform for on-chip mouse zygote injection (figure 5(B)). The platform, fabricated through surface micromahining, integrates the MEMS-based cell immobilization mechnism [133] previously discussed in section  4 and a nanoinjec-tor mechanism, allowing cell immobilization and injection realized on the same chip. However, both the cell immobi-lization mechanism and the nanoinjector machanism were actuated by a manually controlled micromanipulator; there-fore, the cell injection process is operator-skill-dependent and time-consuming.

6. Concluding remarks

MEMS technologies have provided unparalleled capabili-ties of manipulating single cells, studying their functions and mechanisms, and characterizing their physical properties. In this review, we summarized the existing MEMS-based plat-forms that have been applied to different cell manipulation and characterization tasks, including grasping and transfer, patterning and immobilization, injection, mechanical prop-erty characterization, cellular force sensing, and mass and

Figure 5. MEMS-based cell injectors. (A) Schematic diagram of parallel cell injection using a MEMS hollow microneedle array and a vacuum-based cell holding device. Reproduced from [147]. © IOP Publishing Ltd. All rights reserved. (B) A surface-micromachined cell injector including a pair of cell holding meachanisms and an injection mechanism. Reprinted with permission from [149]. Copyright (2014), AIP Publishing LLC.

J. Micromech. Microeng. 27 (2017) 123003

Page 14: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

13

density measurement. Special designs have been adopted to make these MEMS devices suitable for interacting with live cells. Their perfect size matching, high accuracy and sensi-tivity, and high level of integration have led to many unique features benefiting their operations in various studies involv-ing cell manipulation and characterization. Proof-of-concept experiments have been conducted using these platforms, and their significant potential for practical use has been demonstrated.

Despite many advances made in the past few decades, there are still many exciting topics requiring further investigation. To realize high-performance actuation and sensing, many exist-ing platforms adopt conventional MEMS micro actuators and sensors constructed on silicon-based substrates. This brings certain design challenges and/or application limitations of these devices such as electrical and thermal managements and compatibility issues with aqueous environments. Compared to silicon-based materials, polymer materials such as elastomers have several merits for use in MEMS such as low cost, high transparency, high stretchability, good mouldability, and excel-lent chemical inertness. There is a trend in bioMEMS designs to adopt polymer materials, such as PDMS and other biocom-patible polymers, for device construction [151]. Particular attention should be paid to functional polymer materials such as shape memory polymers [152, 153], conductive polymers [154], electroactive polymers [155], which hold huge poten-tial for MEMS applications. Accordingly, research efforts on new designs and microfabrication processes of polymer-based actuators and sensors are required.

In addition, most of the existing MEMS platforms we have reviewed were developed for single tasks of cell manipulation and characterization. It would be desirable to develop inte-grated bioMEMS platforms including multiple MEMS sensing and actuation components, serving as on-chip ‘factories’ for realizing sequential/parallel, multi-step manipulation proce-dures of single cells [156]. For example, If a new bioMEMS platform can be designed to automatically transport cells to mutilple on-chip regions and sequentially perform different manipulation tasks, it could significantly improve the effi-ciency of different kinds of cell studies and potentially enable new studies that cannot be realized using current cell manipu-lation techniques.

Finally, one should note that the practical use of these MEMS platforms in real biological and medical research is still relatively rare, which is partially due to the mental-ity barriers and experimental challenges that biologists and medical scientists have to face when adopting these fancy but unconventional engineering tools. Therefore, as techonolo-gists, we should not limit ourselves to proof-of-concept demonstrations of our new MEMS technologies, but pro-ceed further down the road of transfering them to the hands of their real users. This long-term goal should be pursued by close collaobrations with biological/medical practioners throughout the entire period of technology development, and by efforts on technology transfer from laboratory prototypes to reliable, user-friendly platforms. With the rapid devel-opment of MEMS technologies and the increasingly close collaborations between MEMS technologists and biological/

medical users, it is expected that more and more MEMS cell manipulation platforms will be practically used in biology and medicine in the near furture.

Acknowledgments

The authors acknowledge financial support from the Natu-ral Sciences and Engineering Council of Canada (NSERC) through Discovery Grants to Y S and X L; the Canada Research Chairs Program to Y S; the National Natural Science Foundation of China to W W (grant no 61376120, 61774095, and 21727813) and C R (grant no 61774107); the Tsinghua-Suzhou Innovation Project (grant no 2016SZ0311) to W W; and the Chinese Scholarship Council to P P.

ORCID iDs

Wenhui Wang https://orcid.org/0000-0002-5884-6098Xinyu Liu https://orcid.org/0000-0001-5705-9765

References

[1] Sun Y and Liu X 2015 Micro-and Nanomanipulation Tools vol 13 (New York: Wiley)

[2] Carlo D D and Lee L P 2006 Dynamic single-cell analysis for quantitative biology Anal. Chem. 78 7918–25

[3] Liu X et al 2011 Automated microinjection of recombinant BCL-X into mouse zygotes enhances embryo development Plos One 6 e21687

[4] Lu Z, Zhang X, Leung C, Esfandiari N, Casper R F and Sun Y 2011 Robotic ICSI (intracytoplasmic sperm injection) IEEE Trans. Biomed. Eng. 58 2102–8

[5] Ittner L M and Gotz J 2007 Pronuclear injection for the production of transgenic mice Nat. Protocols 2 1206–15

[6] Liu X, Sun Y, Wang W and Lansdorp B M 2007 Vision-based cellular force measurement using an elastic microfabricated device J. Micromech. Microeng. 17 1281

[7] Sun Y, Wan K-T, Roberts K P, Bischof J C and Nelson B J 2003 Mechanical property characterization of mouse zona pellucida IEEE Trans. Nanobiosci. 2 279–86

[8] Rajagopalan J and Saif M T A 2011 MEMS sensors and microsystems for cell mechanobiology J. Micromech. Microeng. 21 054002

[9] Cermak N et al 2016 High-throughput measurement of single-cell growth rates using serial microfluidic mass sensor arrays Nat. Biotechnol. 34 1052–9

[10] Yeung T et al 2005 Effects of substrate stiffness on cell morphology, cytoskeletal structure, and adhesion Cell Motil. Cytoskeleton 60 24–34

[11] Macaulay I C, Ponting C P and Voet T 2017 Single-cell multiomics: multiple measurements from single cells Trends Genet. 33 155–68

[12] Sun Y and Nelson B J 2004 MEMS for cellular force measurements and molecular detection Int. J. Inf. Acquis. 1 23–32

[13] Kim D-H, Wong P K, Park J, Levchenko A and Sun Y 2009 Microengineered platforms for cell mechanobiology Annu. Rev. Biomed. Eng. 11 203–33

[14] Xiaoyu Rayne Z and Xin Z 2011 Microsystems for cellular force measurement: a review J. Micromech. Microeng. 21 054003

[15] Andersson H and van den Berg A 2003 Microfluidic devices for cellomics: a review Sensors Actuators B 92 315–25

J. Micromech. Microeng. 27 (2017) 123003

Page 15: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

14

[16] Huang L, Bian S T, Cheng Y N, Shi G Y, Liu P, Ye X Y and Wang W H 2017 Microfluidics cell sample preparation for analysis: advances in efficient cell enrichment and precise single cell capture Biomicrofluidics 11 011501

[17] Zare R N and Kim S 2010 Microfluidic platforms for single-cell analysis Annu. Rev. Biomed. Eng. 12 187–201

[18] Mu X, Zheng W, Sun J, Zhang W and Jiang X 2013 Microfluidics for manipulating cells Small 9 9–21

[19] Kim C J, Pisano A P and Muller R S 1992 Silicon-processed overhanging microgripper J. Microelectromech. Syst. 1 31–6

[20] Beyeler F et al 2007 Monolithically fabricated microgripper with integrated force sensor for manipulating microobjects and biological cells aligned in an ultrasonic field J. Microelectromech. Syst. 16 7–15

[21] Kim K, Liu X, Zhang Y and Sun Y 2008 Nanonewton force-controlled manipulation of biological cells using a monolithic MEMS microgripper with two-axis force feedback J. Micromech. Microeng. 18 055013

[22] Perret G et al 2016 Real-time mechanical characterization of DNA degradation under therapeutic x-rays and its theoretical modeling Microsyst. Nanoeng. 2 16062

[23] Chronis N and Lee L P 2005 Electrothermally activated SU-8 microgripper for single cell manipulation in solution J. Microelectromech. Syst. 14 857–63

[24] Zhang J, Onaizah O, Middleton K, You L and Diller E 2017 Reliable grasping of three-dimensional untethered mobile magnetic microgripper for autonomous pick-and-place IEEE Robot. Autom. Lett. 2 835–40

[25] Breger J C et al 2015 Self-folding thermo-magnetically responsive soft microgrippers ACS Appl. Mater. Interfaces 7 3398–405

[26] Yapici M K, Ozmetin A E, Zou J and Naugle D G 2008 Development and experimental characterization of micromachined electromagnetic probes for biological manipulation and stimulation applications Sensors Actuators A 144 213–21

[27] Kim D-H, Lee M G, Kim B and Sun Y 2005 A superelastic alloy microgripper with embedded electromagnetic actuators and piezoelectric force sensors: a numerical and experimental study Smart Mater. Struct. 14 1265

[28] Ger T-R, Huang H-T, Chen W-Y and Lai M-F 2013 Magnetically-controllable zigzag structures as cell microgripper Lab Chip 13 2364–9

[29] Malachowski K, Jamal M, Jin Q, Polat B, Morris C J and Gracias D H 2014 Self-folding single cell grippers Nano Lett. 14 4164–70

[30] Leong T G, Randall C L, Benson B R, Bassik N, Stern G M and Gracias D H 2009 Tetherless thermobiochemically actuated microgrippers Proc. Natl Acad. Sci. 106 703–8

[31] Ok J, Lu Y W and Kim C J C 2006 Pneumatically driven microcage for microbe manipulation in a biological liquid environment J. Microelectromech. Syst. 15 1499–505

[32] Bütefisch S, Seidemann V and Büttgenbach S 2002 Novel micro-pneumatic actuator for MEMS Sensors Actuators A 97 638–45

[33] Yang S and Xu Q 2017 A review on actuation and sensing techniques for MEMS-based microgrippers J. Micro-Bio Robot. 1–14

[34] Carrozza M C, Menciassi A, Tiezzi G and Dario P 1998 The development of a LIGA-microfabricated gripper for micromanipulation tasks J. Micromech. Microeng. 8 141

[35] Maria Chiara C, Anna E, Arianna M, Domenico C, Silvestro M and Paolo D 2000 Towards a force-controlled microgripper for assembling biomedical microdevices J. Micromech. Microeng. 10 271

[36] Millet O et al 2004 Electrostatic actuated micro gripper using an amplification mechanism Sensors Actuators A 114 371–8

[37] Amjad K, Bazaz S A and Lai Y 2008 Design of an electrostatic MEMS microgripper system integrated with force sensor Int. Conf. on Microelectronics, 2008 (ICM 2008) pp 236–9

[38] Chen T, Sun L, Chen L, Rong W and Li X 2010 A hybrid-type electrostatically driven microgripper with an integrated vacuum tool Sensors Actuators A 158 320–7

[39] Khan F, Bazaz S A and Sohail M 2010 Design, implementation and testing of electrostatic SOI MUMPs based microgripper Microsyst. Technol. 16 1957–65

[40] Bazaz S A, Khan F and Shakoor R I 2011 Design, simulation and testing of electrostatic SOI MUMPs based microgripper integrated with capacitive contact sensor Sensors Actuators A 167 44–53

[41] Volland B E, Heerlein H and Rangelow I W 2002 Electrostatically driven microgripper Microelectron. Eng. 61–2 1015–23

[42] Arai F, Andou D, Nonoda Y, Fukuda T, Iwata H and Itoigawa K 1998 Integrated microendeffector for micromanipulation IEEE/ASME Trans. Mechatron. 3 17–23

[43] Xu Q 2015 Design, fabrication, and testing of an MEMS microgripper with dual-axis force sensor IEEE Sens. J. 15 6017–26

[44] Muntwyler S, Kratochvil B E, Beyeler F and Nelson B J 2010 Monolithically integrated two-axis microtensile tester for the mechanical characterization of microscopic samples J. Microelectromech. Syst. 19 1223–33

[45] Piriyanont B and Moheimani S R 2014 MEMS rotary microgripper with integrated electrothermal force sensor J. Microelectromech. Syst. 23 1249–51

[46] Kristian M and Ole H 2005 Electro-thermally actuated microgrippers with integrated force-feedback J. Micromech. Microeng. 15 1265

[47] Voicu R, Esinenco D, Müller R, Eftime L and Tibeica C 2007 Method for overcoming the unwanted displacements of an electro-thermally actuated microgripper Proc. Int. Conf. on Multi-Material Micro Manufacture (4M) pp 39–42

[48] Nguyen N-T, Ho S-S and Low C L-N 2004 A polymeric microgripper with integrated thermal actuators J. Micromech. Microeng. 14 969

[49] Solano B and Wood D 2007 Design and testing of a polymeric microgripper for cell manipulation Microelectron. Eng. 84 1219–22

[50] Solano B P, Gallant A J and Wood D 2009 Design and optimisation of a microgripper: Demonstration of biomedical applications using the manipulation of oocytes MEMS/MOEMS’09. Symp. on Design, Test, Integration & Packaging of MEMS/MOEMS, 2009 pp 61–5

[51] Daunton R, Gallant A, Wood D and Kataky R 2011 A thermally actuated microgripper as an electrochemical sensor with the ability to manipulate single cells Chem. Commun. 47 6446–8

[52] Solano B, Gallant A J, Greggains G D, Wood D and Herbert M 2008 Low voltage microgripper for single cell manipulation Adv. Sci. Technol. 57 67–72

[53] Colinjivadi K S, Lee J-B and Draper R 2008 Viable cell handling with high aspect ratio polymer chopstick gripper mounted on a nano precision manipulator Microsyst. Technol. 14 1627–33

[54] Zhang R, Chu J, Wang H and Chen Z 2013 A multipurpose electrothermal microgripper for biological micro-manipulation Microsyst. Technol. 19 89–97

[55] Kim K, Liu X, Zhang Y, Cheng J, Yu Wu X and Sun Y 2008 Elastic and viscoelastic characterization of microcapsules for drug delivery using a force-feedback MEMS microgripper Biomed. Microdevices 11 421

[56] Li W J and Xi N 2004 Novel micro gripping, probing, and sensing devices for single-cell surgery Engineering in

J. Micromech. Microeng. 27 (2017) 123003

Page 16: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

15

Medicine and Biology Society, 2004. IEMBS’04. 26th Annual Int. Conf. of the IEEE pp 2591–4

[57] Duc T C, Lau G-K, Creemer J F and Sarro P M 2008 Electrothermal microgripper with large jaw displacement and integrated force sensors J. Microelectromech. Syst. 17 1546–55

[58] Qu J, Zhang W, Jung A, Cruz S S-D and Liu X 2017 Microscale compression and shear testing of soft materials using an MEMS microgripper with two-axis actuators and force sensors IEEE Trans. Autom. Sci. Eng. 14 834–43

[59] Guan C and Zhu Y 2010 An electrothermal microactuator with Z-shaped beams J. Micromech. Microeng. 20 085014

[60] Ouyang J and Zhu Y 2012 Z-shaped MEMS thermal actuators: piezoresistive self-sensing and preliminary results for feedback control J. Microelectromech. Syst. 21 596–604

[61] Zhu Y, Moheimani S R and Yuce M R 2012 Bidirectional electrothermal actuator with Z-shaped beams IEEE Sens. J. 12 2508–9

[62] Yang S and Xu Q 2016 Design of a microelectromechanical systems microgripper with integrated electrothermal actuator and force sensor Int. J. Adv. Robot. Syst. 13 1–10

[63] Ho-Yin C and Li W J 2003 A thermally actuated polymer micro robotic gripper for manipulation of biological cells 2003 IEEE Int. Conf. on Robotics and Automation (Cat. No.03CH37422) vol 1 pp 288–93

[64] Yong Z, Alberto C and Horacio D E 2006 A thermal actuator for nanoscale in situ microscopy testing: design and characterization J. Micromech. Microeng. 16 242

[65] Qin Q and Zhu Y 2013 Temperature control in thermal microactuators with applications to in situ nanomechanical testing Appl. Phys. Lett. 102 013101

[66] Diller E and Sitti M 2014 Three-dimensional programmable assembly by untethered magnetic robotic micro-grippers Adv. Funct. Mater. 24 4397–404

[67] Zhang J and Diller E 2016 Tetherless mobile micrograsping using a magnetic elastic composite material Smart Mater. Struct. 25 11LT03

[68] Malachowski K et al 2014 Stimuli-responsive theragrippers for chemomechanical controlled release Angew. Chem. 126 8183–7

[69] Randall C L, Gultepe E and Gracias D H 2012 Self-folding devices and materials for biomedical applications Trends Biotechnol. 30 138–46

[70]Wei M, Gao Y, Li X and Serpe M J 2017 Stimuli-responsive polymers and their applications Polym. Chem. 8 127–43

[71] Seidemann V, Bütefisch S and Büttgenbach S 2002 Fabrication and investigation of in-plane compliant SU8 structures for MEMS and their application to micro valves and micro grippers Sensors Actuators A 97 457–61

[72] Fung C K M, Elhajj I, Li W J and Ning X 2002 A 2D PVDF force sensing system for micro-manipulation and micro-assembly Proc. 2002 IEEE Int. Conf. on Robotics and Automation vol 2 pp 1489–94

[73] Deok-Ho K, Chang Nam H, Yu S, Sang Ho L, Byungkyu K and Nelson B J 2006 Mechanical analysis of chorion softening in prehatching stages of zebrafish embryos IEEE Trans. NanoBiosci. 5 89–94

[74] Yu X, Dong S, Tse H Y G, Chong L and Shuk Han C 2011 Force sensing and manipulation strategy in robot-assisted microinjection on zebrafish embryos IEEE/ASME Trans. Mechatron. 16 1002–10

[75] Huang H B, Dong S, Mills J K and Shuk Han C 2009 Robotic cell injection system with position and force control: toward automatic batch biomanipulation IEEE Trans. Robot. 25 727–37

[76] Zhang X et al 2004 Micromachined silicon force sensor based on diffractive optical encoders for characterization of microinjection Sensors Actuators A 114 197–203

[77] Liu X Y, Kim K, Zhang Y and Sun Y 2009 Nanonewton force sensing and control in microrobotic cell manipulation Int. J. Robot. Res. 28 1065–76

[78] Tan J L, Tien J, Pirone D M, Gray D S, Bhadriraju K and Chen C S 2003 Cells lying on a bed of microneedles: an approach to isolate mechanical force Proc. Natl Acad. Sci. 100 1484–9

[79] Yang S and Saif M T A 2007 MEMS based force sensors for the study of indentation response of single living cells Sensors Actuators A 135 16–22

[80] Sun Y, Nelson B J, Potasek D P and Enikov E 2002 A bulk microfabricated multi-axis capacitive cellular force sensor using transverse comb drives J. Micromech. Microeng. 12 832

[81] Sieber A et al 2008 A novel haptic platform for real time bilateral biomanipulation with a MEMS sensor for triaxial force feedback Sensors Actuators A 142 19–27

[82] Engler A J, Sen S, Sweeney H L and Discher D E 2006 Matrix elasticity directs stem cell lineage specification Cell 126 677–89

[83] Pelham R J and Wang Y-l 1997 Cell locomotion and focal adhesions are regulated by substrate flexibility Proc. Natl Acad. Sci. 94 13661–5

[84] Suresh S 2007 Biomechanics and biophysics of cancer cells Acta Biomater. 3 413–38

[85] Sleep J, Wilson D, Simmons R and Gratzer W 1999 Elasticity of the red cell membrane and its relation to hemolytic disorders: an optical tweezers study Biophys. J. 77 3085–95

[86] Cooke B M, Mohandas N and Coppel R L 2001 The malaria-infected red blood cell: structural and functional changes Adv. Parasitol. 50 1–86

[87] Moeendarbary E and Harris A R 2014 Cell mechanics: principles, practices, and prospects Wiley Interdiscip. Rev. 6 371–88

[88] Liu X Y, Shi J Y, Zong Z, Wan K T and Sun Y 2012 Elastic and viscoelastic characterization of mouse oocytes using micropipette indentation Ann. Biomed. Eng. 40 2122–30

[89] Liu X Y, Fernandes R, Jurisicova A, Casper R F and Sun Y 2010 In situ mechanical characterization of mouse oocytes using a cell holding device Lab Chip 10 2154–61

[90] Barazani B, Warnat S, Fine A and Hubbard T 2017 MEMS squeezer for the measurement of single cell rupture force, stiffness change, and hysteresis J. Micromech. Microeng. 27 025002

[91] Burri J T et al 2016 Dual-axis cellular force microscope for mechanical characterization of living plant cells 2016 IEEE Int. Conf. on Automation Science and Engineering (CASE) pp 942–7

[92] Sun Y, Nelson B J and Greminger M A 2005 Investigating protein structure change in the zona pellucida with a microrobotic system Int. J. Robot. Res. 24 211–8

[93] Lauffenburger D A and Horwitz A F 1996 Cell migration: a physically integrated molecular process Cell 84 359–69

[94] Polacheck W J and Chen C S 2016 Measuring cell-generated forces: a guide to the available tools Nat. Methods 13 415–23

[95] Harris A K, Wild P and Stopak D 1980 Silicone rubber substrata: a new wrinkle in the study of cell locomotion Science 208 177–9

[96] Wang Y-L and Pelham R J 1998 Preparation of a flexible, porous polyacrylamide substrate for mechanical studies of cultured cells Methods Enzymol. 298 489–96

[97] Munevar S, Wang Y-l and Dembo M 2001 Traction force microscopy of migrating normal and H-ras transformed 3T3 fibroblasts Biophys. J. 80 1744–57

[98] Pelham R J and Wang Y-l 1999 High resolution detection of mechanical forces exerted by locomoting fibroblasts on the substrate Mol. Biol. Cell 10 935–45

J. Micromech. Microeng. 27 (2017) 123003

Page 17: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

16

[99] Dembo M and Wang Y-L 1999 Stresses at the cell-to-substrate interface during locomotion of fibroblasts Biophys. J. 76 2307–16

[100] Balaban N Q et al 2001 Force and focal adhesion assembly: a close relationship studied using elastic micropatterned substrates Nat. Cell Biol. 3 466

[101] Galbraith C G and Sheetz M P 1997 A micromachined device provides a new bend on fibroblast traction forces Proc. Natl Acad. Sci. 94 9114–8

[102] Lin G, Pister K S and Roos K P 2000 Surface micromachined polysilicon heart cell force transducer J. Microelectromech. Syst. 9 9–17

[103] Park J et al 2005 Real-time measurement of the contractile forces of self-organized cardiomyocytes on hybrid biopolymer microcantilevers Anal. Chem. 77 6571–80

[104] Park J, Kim J, Roh D, Park S, Kim B and Chun K 2006 Fabrication of complex 3D polymer structures for cell-polymer hybrid systems J. Micromech. Microeng. 16 1614

[105] Zhao Y and Zhang X 2006 Cellular mechanics study in cardiac myocytes using PDMS pillars array Sensors Actuators A 125 398–404

[106] Petronis S, Gold J and Kasemo B 2003 Microfabricated force-sensitive elastic substrates for investigation of mechanical cell-substrate interactions J. Micromech. Microeng. 13 900

[107] Ganz A et al 2006 Traction forces exerted through N-cadherin contacts Biol. Cell 98 721–30

[108] Noda K, Hirayama K, Matsumoto K and Shimoyama I 2016 Micro pillars with thin hydrophobic layer formed on the side walls to prevent cell protrusion toward side wall 2016 IEEE 29th Int. Conf. on Micro Electro Mechanical Systems (MEMS) pp 501–4

[109] Zhao Y, Lim C C, Sawyer D B, Liao R and Zhang X 2007 Simultaneous orientation and cellular force measurements in adult cardiac myocytes using three-dimensional polymeric microstructures Cell Motil. Cytoskeleton 64 718–25

[110] Du P, Lin I K, Lu H and Zhang X 2010 Extension of the beam theory for polymer bio-transducers with low aspect ratios and viscoelastic characteristics J. Micromech. Microeng. 20 095016

[111] Lin I K, Ou K S, Liao Y M, Liu Y, Chen K S and Zhang X 2009 Viscoelastic characterization and modeling of polymer transducers for biological applications J. Microelectromech. Syst. 18 1087–99

[112] Du Roure O et al 2005 Force mapping in epithelial cell migration Proc. Natl Acad. Sci. USA 102 2390–5

[113] Trichet L et al 2012 Evidence of a large-scale mechanosensing mechanism for cellular adaptation to substrate stiffness Proc. Natl Acad. Sci. 109 6933–8

[114] Fu J et al 2010 Mechanical regulation of cell function with geometrically modulated elastomeric substrates Nat. Methods 7 733

[115] Yang M T, Sniadecki N J and Chen C S 2007 Geometric considerations of micro-to nanoscale elastomeric post arrays to study cellular traction forces Adv. Mater. 19 3119–23

[116] Ghibaudo M, Di Meglio J-M, Hersen P and Ladoux B 2011 Mechanics of cell spreading within 3D-micropatterned environments Lab Chip 11 805–12

[117] Sniadecki N J et al 2007 Magnetic microposts as an approach to apply forces to living cells Proc. Natl Acad. Sci. 104 14553–8

[118] Yang S and Saif T 2005 Micromachined force sensors for the study of cell mechanics Rev. Sci. Instrum. 76 044301

[119] Yang S and Saif T 2005 Reversible and repeatable linear local cell force response under large stretches Exp. Cell Res. 305 42–50

[120] Rajagopalan J, Tofangchi A and Saif M T A 2010 Linear high-resolution bioMEMS force sensors with large measurement range J. Microelectromech. Syst. 19 1380–9

[121] Yang S and Saif M T A 2007 Force response and actin remodeling (agglomeration) in fibroblasts due to lateral indentation Acta Biomater. 3 77–87

[122] Siechen S, Yang S, Chiba A and Saif T 2009 Mechanical tension contributes to clustering of neurotransmitter vesicles at presynaptic terminals Proc. Natl Acad. Sci. 106 12611–6

[123] Serrell D B, Oreskovic T L, Slifka A J, Mahajan R L and Finch D S 2007 A uniaxial bioMEMS device for quantitative force-displacement measurements Biomed. Microdevices 9 267–75

[124] Serrell D B, Law J, Slifka A J, Mahajan R L and Finch D S 2008 A uniaxial bioMEMS device for imaging single cell response during quantitative force-displacement measurements Biomed. Microdevices 10 883

[125] Alvarez-Larrán A et al 2012 Red cell mass measurement in patients with clinically suspected diagnosis of polycythemia vera or essential thrombocythemia Haematologica 97 1704–7

[126] Ilic B et al 2001 Single cell detection with micromechanical oscillators J. Vac. Sci. Technol. B 19 2825–8

[127] Park K et al 2010 Measurement of adherent cell mass and growth Proc. Natl Acad. Sci. 107 20691–6

[128] Ekinci K L and Roukes M L 2005 Nanoelectromechanical systems Rev. Sci. Instrum. 76 061101

[129] Ekinci K L, Huang X M H and Roukes M L 2004 Ultrasensitive nanoelectromechanical mass detection Appl. Phys. Lett. 84 4469–71

[130] Davila A P, Jang J, Gupta A K, Walter T, Aronson A and Bashir R 2007 Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water Biosens. Bioelectron. 22 3028–35

[131] Godin M, Bryan A K, Burg T P, Babcock K and Manalis S R 2007 Measuring the mass, density, and size of particles and cells using a suspended microchannel resonator Appl. Phys. Lett. 91 123121

[132] Burg T P et al 2007 Weighing of biomolecules, single cells and single nanoparticles in fluid Nature 446 1066

[133] Teichert G H, Aten Q T, Burnett S H, Howell L L and Jensen B D 2012 Cylindrical single-degree-of-freedom spatial mechanisms for cell restraint J. Mech. Robot. 4 021011

[134] Rettig J R and Folch A 2005 Large-scale single-cell trapping and imaging using microwell arrays Anal. Chem. 77 5628–34

[135] Liu X and Sun Y 2009 Microfabricated glass devices for rapid single cell immobilization in mouse zygote microinjection Biomed. Microdevices 11 1169

[136] Lee P J, Hung P J, Shaw R, Jan L and Lee L P 2005 Microfluidic application-specific integrated device for monitoring direct cell–cell communication via gap junctions between individual cell pairs Appl. Phys. Lett. 86 223902

[137] Khine M, Ionescu-Zanetti C, Blatz A, Wang L-P and Lee L P 2007 Single-cell electroporation arrays with real-time monitoring and feedback control Lab Chip 7 457–62

[138] Park J, Jung S-H, Kim Y-H, Kim B, Lee S-K and Park J-O 2005 Design and fabrication of an integrated cell processor for single embryo cell manipulation Lab Chip 5 91–6

[139] Gajasinghe R W et al 2016 Rare cell immobilization on MEMS scale sensors using micro-electromagnets IEEE Sens. J. 16 7572–80

J. Micromech. Microeng. 27 (2017) 123003

Page 18: Journal of Micromechanics and Microengineering TOPICAL ...amnl.mie.utoronto.ca/data/J144.pdf · Jagannathan Rajagopalan and M Taher A Saif-This content was downloaded from IP address

Topical Review

17

[140] Lee H, Liu Y, Ham D and Westervelt R M 2007 Integrated cell manipulation system-CMOS/microfluidic hybrid Lab Chip 7 331–7

[141] Wang W H, Liu X Y and Sun Y 2009 High-throughput automated injection of individual biological cells IEEE Trans. Autom. Sci. Eng. 6 209–19

[142] Trimmer W et al 1995 Injection of DNA into plant and animal tissues with micromechanical piercing structures Proc. of the IEEE Microelectromechanical Systems Workshop 8th (Amsterdam) pp 111–5

[143] Hashmi S, Ling P, Hashmi G, Reed M, Gaugler R and Trimmer W 1995 Genetic transformation of nematodes using arrays of micromechanical piercing structures BioTechniques 19 766–70

[144] Teichert G H, Burnett S and Jensen B D 2013 A microneedle array able to inject tens of thousands of cells simultaneously J. Micromech. Microeng. 23 095003

[145] Deng Y et al 2016 Transdermal delivery of siRNA through microneedle array Sci. Rep. 6 21422

[146] Dul M et al 2017 Hydrodynamic gene delivery in human skin using a hollow microneedle device J. Control. Rel. accepted (https://doi.org/10.1016/j.jconrel.2017.02.028)

[147] Chun K, Hashiguchi G, Toshiyoshi H and Fujita H 1999 Fabrication of array of hollow microcapillaries used for injection of genetic materials into animal/plant cells Japan. J. Appl. Phys. 38 L279

[148] Ichiki T, Sugiyama Y, Kase S and Horiike Y Surface micromachined hollow microneedle array integrated on a microfluidic chip Int. Conf. on Miniaturized Chemical and Biochemical Analysis Systems (MicroTAS) pp 1025–8

[149] Aten Q T, Jensen B D, Burnett S H and Howell L L 2014 A self-reconfiguring metamorphic nanoinjector for injection into mouse zygotes Rev. Sci. Instrum. 85 055005

[150] Adamo A and Jensen K F 2008 Microfluidic based single cell microinjection Lab Chip 8 1258–61

[151] Liu C 2007 Recent developments in polymer MEMS Adv. Mater. 19 3783–90

[152] Gall K, Kreiner P, Turner D and Hulse M 2004 Shape-memory polymers for microelectromechanical systems J. Microelectromech. Syst. 13 472–83

[153] Eisenhaure J D, Rhee S I, Al-Okaily A M, Carlson A, Ferreira P M and Kim S 2016 The use of shape memory polymers for MEMS assembly J. Microelectromech. Syst. 25 69–77

[154] Ruhhammer J, Zens M, Goldschmidtboeing F, Seifert A and Woias P 2015 Highly elastic conductive polymeric MEMS Sci. Technol. Adv. Mater. 16 015003

[155] Wang T et al 2016 Electroactive polymers for sensing Interface Focus 6 20160026

[156] Seker E, Sung J H, Shuler M L and Yarmush M L 2011 Solving medical problems with BioMEMS IEEE Pulse 2 51–9

J. Micromech. Microeng. 27 (2017) 123003