Thermo ScientificGlycan Analysis for Biotherapeutics
• Intact Glycoproteins• Glycopeptides • Free Glycans• Monosacccharides
Join the sweet revolution in biopharmaceuticals
Biotherapeutic proteins, which include
antibodies, are becoming the fastest growing
category of drugs due to their efficacy
for patient health. The complex nature of
these large molecules brings major new
challenges to the pharmaceutical scientist.
The industry is undergoing a scientific
revolution as it adapts to meet the challenges
of characterizing biotherapeutics.
WHAT IS MY GLYCOSYLATION PATTERN? Intact Glycoprotein analysis
1WHERE DO MY GLYCANS RESIDE? Glycopeptide profiling
22 3
Glycosylation of biotherapeutic medicines
plays a critical role in the efficacy of the drug.
In-depth characterization of these glycans (complex sugars) bound to the drug entity is mandatory and challenging. To overcome this challenge, we have developed a series of four simple workflow solutions based on leading technology platforms.
THE CHALLENGES of Glycan Characterization
MEETING
4WHAT IS THE COMPOSITION OF SUGARS IN MY DRUG ENTITY? Monosaccharide analysis
WHICH GLYCANS ARE IN MY DRUG AND WHAT IS THEIR CONCENTRATION? Glycan structure determination
3
Analyze Intact ProteinsMany biopharmaceutical and biological research applications require analysis of proteins in their native (intact) state. The Thermo Scientific™ Exactive™ Plus EMR mass spectrometer combines unsurpassed high-resolution accurate-mass analysis with an extended mass range (EMR) to create an outstanding tool for investigating the structure, topology, and architecture of native-like tertiary and quaternary protein structures. A superb tool for high-performance screening of monoclonal antibodies, antibody-drug conjugates (ADC), PEG-ylated proteins, oligomerized protein-based drugs and glycoforms.
Deconvolute Protein SpectraScreen, identify, and characterize intact proteins with higher productivity and confidence using Thermo Scientific™ Protein Deconvolution software. The software uses not one, but two deconvolution algorithms. One algorithm to take full advantage of the high-quality, high-resolution accurate-mass (HRAM) data produced by Thermo Scientific™ Orbitrap™ based mass spectrometers. The second algorithm is for lower resolution spectra where the mass spectral peaks are not isotopically resolved.
INTACT GLYCOPROTEINIsolated antibodies and large proteins are often chemically reduced prior to analysis.
SEPARATE GLYCOPROTEINSAdvanced ion exchange or hydrophobic interaction chromatography columns allow full separation of antibody fragments.
LIQUID CHROMATOGRAPHYReproducible, bio-compatible chromatography is required to simplify variants.
CONFIRM MASS OF GLYCOPROTEINHigh resolution and mass accuracy are required together with deconvolution software to interpret spectra.
4 5
IS MY Glycosylation Pattern?
WHAT
Intact Glycoprotein Analysis Workflow
Extended mass range (EMR) of up to m/z 20,000 and improved detection of high-mass ions.
Analyze with Mass Spectrometry Intact glycoprotein profiling is used to ascertain the pattern and degree of glycosylation. Due to the heterogeneity of the attached glycan moieties, intact glycoprotein profiling is best performed using high resolution/accurate mass (HR/AM) mass spectrometry together with chromatographic separation to gain full insight into the various glycoforms present on a protein or antibody.
3260 3270 3280 3290m/z
0 10 20 30 40 50 60
70
80 90
100
Rela
tive
Abun
danc
e
3272.96 3276.58
3269.31 3280.12
3283.743266.23 3290.26
zoom
2500 3000 3500 4000 m/z
0 10 20 30 40 50 60 70 80 90
100
Rela
tive
Abun
danc
e
3272.96
3347.33 3137.16
3425.13 3068.50 3005.83 3506.59
3592.19 2945.77 3686.06 2888.16
3776.35 2832.49 3875.98 2776.10
3984.74 2632.99 4208.14 2303.96
146925.606146619.406 148010.563162 Da 162 Da162 Da 162 Da162 Da
146619.406Man5/Man5
(G1F/G2F)SA1
(G1F/G2F)SA2
G1F/G2FSA2
G1F/G2FSA1
146541.406
146925.606
Man5/Man5(G2F/G2F)SA2
+2740.35+2673.54
+2513.07
(G2F/G2F)SA1
100
80
60
40
20
0
0
1
2
3
4
146600mass
mass
abun
danc
eab
unda
nce
146800 147000 147200 147400 147600 147800 148000 148200
146600
146698.328
146858.797
147075.969 147237.734 147399.516 147561.766 147721.813 147854.688
148010.563 148144.984148307.484
146800 147000 147200 147400 147600 147800 148000 148200
146698.328 146858.797
147075.969
147237.734147399.516
147561.766
147721.813147854.688 148144.984 148307.484
NL: 9.34E7
NL: 9.34E7
162 Da
Spectrum of Rituximab. Insert shows the different glycoforms of the molecule.
Deconvoluted spectrum of rituximab glycoforms confirmed with accurate mass.
Separate Antibody Variants & Fragments Thermo Scientific™ MAbPac™ columns are designed for the separation of monoclonal antibodies (mAbs) and related biologics by hydrophobic interaction (HIC), ion exchange (IEC), size exclusion (SEC) and reverse phase (RP) chromatography. This suite of columns have unique chemistries to provide high resolution, excellent bio-compatibility, and complementary selectivity suitable for a broad range of assays for mAbs and related substances.
0.0 1.3 2.5 3.8 5.0 6.3 7.5 8.8 10.0 12.0
Cetuximab - MAbPac RP
min
5.00 5.50 6.00 6.50 7.00 7.50 8.000.0
10.0
20.0
30.0
40.0
50.0 MABPacRP #17 CET UV_VIS_1mAU
min
WVL:214 nm
Separation of Cetuximab variants using a MAbPac RP column.
ANALYZE AND MAP
Glycopeptide mapping can be performed rapidly and accurately with the combination of any of our Thermo Scientific™ Q Exactive™ family of Orbitrap powered mass spectrometers, combined with the latest software for comprehensive mapping of biotherapeutic proteins - PepFinder.
For more advanced characterization of an intact glycopeptide, multiple fragmentations are required: HCD Higher-energy collisional dissociation provides information about the glycan composition and ETD (electron transfer dissociation) provides extensive fragmentation along the peptide batckbone to enable sequencing of the peptide while preserving attachment of the glycans, allowing localization of the glycosylation sites. ETD is available on Thermo Scientific™ Orbitrap Fusion Lumos™ Tribrid™ MS.
INTACT GLYCOPROTEINIsolate antibody or glycoprotein.
DIGEST TO GLYCOPEPTIDESReproducible, fast, digestion in less than one hour.
SEPARATE GLYCOPEPTIDESGlycopeptides can be separated faster using advanced UHPLC columns.
ANALYZE & MAPRoutine peptide mapping provides protein sequence incluiding glycopetides.Advanced MS fragmentation provides exact glycopeptide location information.
7
DO MY Glycans Reside?
WHERE
Glycopeptide Mapping Workflow
Glycan analysis can also be performed at the peptide level, with the goal of obtaining both glycan composition and peptide sequence at the site of glycosylation.
DIGEST
Thermo Scientific™ SMART Digest™ kits are designed for biopharmaceutical applications that require highly reproducible, sensitive and fast analysis, often in high throughput workflows. The kit uses unique optimized heat-stable immobilized trypsin technology.
SMART Digest allows complete antibody digestion in just 60 minutes; a saving of up to 23 hours versus in-solution digestion methods.
SEPARATE PEPTIDES
The glycopeptides can then be separated in a few minutes with the highest speed and resolution using the biocompatible Thermo Scientific™ Vanquish™ UHPLC system together with Thermo Scientific™ Accucore™ C18 or Acclaim 120 RS UHPLC columns.
Determine the Exact Location of GlycosylationThe Orbitrap Fusion Lumos Tribrid MS is the most sensitive Orbitrap instrument available and can perform a wide variety of analyses, from in-depth discovery experiments to characterization of complex PTMs to comprehensive qual/quan workflows. The availability of multiple fragmentation techniques - CID, HCD, ETD; combined ionization spectra such as EThcD; and also product dependent acquisition (such as HCDpdETD), which generates a pair of HCD and ETD spectra. At any stage of MSn, with fragment ion detection in either the ion trap or Orbitrap mass analyzer, offers a new level of versatility and performance for the most challenging applications. Such as, the identification and location of glycosylated peptides.
Resolution up to 500,000 FWHM and exceptional <1 ppm mass accuracy provides absolute confidence in glycopeptide identification.
6
Simple, Advanced Peptide Mapping Software Thermo Scientific™ PepFinder™ software provides accurate identification, in-depth characterization, and relative quantitation of biotherapeutic and other proteins from mass spectrometric data. It provides an automated workflow for glycopeptide identification, disulfide bond mapping, and quantification of PTMs. PepFinder software automates previously time-consuming manual processes, processing complex data and integrating the results into concise, informative reports.
200 400 600 800 1000 1200 1400 1600 1800 2000m/z
0
10
20
30
40
50
60
70
80
90
100
Rela
tive
Abu
ndan
ce
C7H
8NO
2
z1 Hex
NAc
-36
y1b2
Hex
NAc
b3
c3N
euAc
-18
Neu
Ac
z2 y2c6++
c4c8++
Hex
NAc
Hex
y7++c9++
z3y3
c11++
c10++
c5
z9++y9++
z4z10++ Hex
Hex
NAc
Neu
Ac
z15++c14++b14++
z11++
c13++c12++
M+e
-Neu
Ac
M+2
e-N
euAc
c13+++
c14+++
z12+++z13+++z14+++
c18+++_Iso1c19+++_Iso1z18+++_Iso1M
+3e-
Neu
Ac
c20+++_Iso1
M_5
+ - H
exN
AcH
exM
_5+
- Neu
Ac(2
)M
_5+
- Hex
NAc
Hex
Neu
Ac
y6z6c7Pep
+Hex
NAc
4+
c6z7c9 b10z8 z21+++_Iso1
c21+++_Iso1y7
G H G H R N G T G H G N S T H H G P E Y M REThcD
z17+++_Iso1
M+e
M+2
e
M+3
e
200 400 600 800 1000 1200 1400 1600 1800 2000m/z
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Rela
tive
Abu
ndan
ce
C6H
8NO
2C7
H8N
O2
Hex
Hex
NAc
-36
Hex
NAc
-18
Hex
NAc
y1b2
Neu
Ac-1
8N
euAc
b6++
Hex
NAc
Hex
y7++y3
b5 Pep+
Hex
NAc
4+
Hex
Neu
AcH
exN
Ac
b6
y5 Pep+
2Hex
NAc
4+
y6Pep+
2Hex
NAc
+2H
ex4+
Pep3+
Pep+
2Hex
NAc
+3H
ex4+
Pep+
Hex
NAc
3+
Pep+
3Hex
NAc
+3H
ex4+
y7b9 Pep+
3Hex
NAc
+4H
ex4+
Pep+
2Hex
NAc
3+
Pep+
2Hex
NAc
+Hex
3+
Pep+
2Hex
NAc
+2H
ex3+
Pep+
2Hex
NAc
+3H
ex3+
Pep+
3Hex
NAc
+3H
ex3+
Pep2+
Pep+
3Hex
NAc
+4H
ex3+
Pep+
Hex
NAc
2+
Pep+
2Hex
NAc
2+
Pep+
2Hex
NAc
+Hex
2+
Pep+
2Hex
NAc
+2H
ex2+
Pep+
2Hex
NAc
+3H
ex2+
b16
G H G H R N G T G H G N S T H H G P E Y M RHCD
200 400 600 800 1000 1200 1400 1600 1800 2000m/z
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Rela
tive
Abu
ndan
ce
z1
y1
c2
c3
z2y2
c4
c8++
z3
y3z8++
c10++
c11++
c5
z4
z10++c6y5c7y6z6
c8
z7
y7c9z8
c10
c11 c12++c14++
G H G H R N G T G H G N S T H H G P E Y M R
z9++
ETD
200 400 600 800 1000 1200 1400 1600 1800 2000m/z
0
10
20
30
40
50
60
70
80
90
100
Rela
tive
Abu
ndan
ce
C7H
8NO
2
z1 Hex
NAc
-36
y1b2
Hex
NAc
b3
c3N
euAc
-18
Neu
Ac
z2 y2c6++
c4c8++
Hex
NAc
Hex
y7++c9++
z3y3
c11++
c10++
c5
z9++y9++
z4z10++ Hex
Hex
NAc
Neu
Ac
z15++c14++b14++
z11++
c13++c12++
M+e
-Neu
Ac
M+2
e-N
euAc
c13+++
c14+++
z12+++z13+++z14+++
c18+++_Iso1c19+++_Iso1z18+++_Iso1M
+3e-
Neu
Ac
c20+++_Iso1
M_5
+ - H
exN
AcH
exM
_5+
- Neu
Ac(2
)M
_5+
- Hex
NAc
Hex
Neu
Ac
y6z6c7Pep
+Hex
NAc
4+
c6z7c9 b10z8 z21+++_Iso1
c21+++_Iso1y7
G H G H R N G T G H G N S T H H G P E Y M REThcD
z17+++_Iso1
M+e
M+2
e
M+3
e
200 400 600 800 1000 1200 1400 1600 1800 2000m/z
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Rela
tive
Abu
ndan
ce
C6H
8NO
2C7
H8N
O2
Hex
Hex
NAc
-36
Hex
NAc
-18
Hex
NAc
y1b2
Neu
Ac-1
8N
euAc
b6++
Hex
NAc
Hex
y7++y3
b5 Pep+
Hex
NAc
4+
Hex
Neu
AcH
exN
Ac
b6
y5 Pep+
2Hex
NAc
4+
y6Pep+
2Hex
NAc
+2H
ex4+
Pep3+
Pep+
2Hex
NAc
+3H
ex4+
Pep+
Hex
NAc
3+
Pep+
3Hex
NAc
+3H
ex4+
y7b9 Pep+
3Hex
NAc
+4H
ex4+
Pep+
2Hex
NAc
3+
Pep+
2Hex
NAc
+Hex
3+
Pep+
2Hex
NAc
+2H
ex3+
Pep+
2Hex
NAc
+3H
ex3+
Pep+
3Hex
NAc
+3H
ex3+
Pep2+
Pep+
3Hex
NAc
+4H
ex3+
Pep+
Hex
NAc
2+
Pep+
2Hex
NAc
2+
Pep+
2Hex
NAc
+Hex
2+
Pep+
2Hex
NAc
+2H
ex2+
Pep+
2Hex
NAc
+3H
ex2+
b16
G H G H R N G T G H G N S T H H G P E Y M RHCD
200 400 600 800 1000 1200 1400 1600 1800 2000m/z
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
Rela
tive
Abu
ndan
ce
z1
y1
c2
c3
z2y2
c4
c8++
z3
y3z8++
c10++
c11++
c5
z4
z10++c6y5c7y6z6
c8
z7
y7c9z8
c10
c11 c12++c14++
G H G H R N G T G H G N S T H H G P E Y M R
z9++
ETD
Multiple fragmentation techniques allow unambiguous assignment of glycosylation site.
ANALYZE LC
ANALYZE LC-MSINTACT GLYCOPROTEINIsolate antibody or glycoprotein.
RELEASE GLYCANSGlycans are released enzymatically using glycosidase.
LABEL GLYCANSChemically react to add either a fluorophore or aminoxy tandem mass tag (TMT).
SEPARATESelective chemistries using combined HIC/WAX phases provide exceptional glycan separations.
ANALYZE & QUANTIFYSeparate and detect fluorescence labelled glycans.
9
ARE IN MY DRUG AND what is their concentration?
WHICH GLYCANS
Free Glycan Analysis Workflow
Monitoring of specifc glycan species or determination of relative quantities of a particular set of glycans provides important information for the development of biotherapeutics. Due to the complexity of glycan structures, quantiation and identification is performed upon release of glycans from the protein. N-linked glycans are released by enzymatic treartment, whereas O-linked glycans needs to be relased by chemical method as no enzyme exists for this purpose.
Glycans have no chromophore and have a poor response with conventional LC-UV detection. Glycans can be labelled with fluorescent tags prior to high sensitivity analysis by LC-Fluorescence detection. The most common label being 2-aminobenzamide (2-AB). Mass spectrometry has emerged as one of the most powerful tools for glycan structure elucidation. However, as most glycans do not ionize efficiently 2-AB labelling can also be performed to improve sensitivity. Thermo Scientific™ aminoxyTMT™ (Tandem Mass Tag™) reagents can also be used for labeling proteins or released glycans. This enables multiplexing experiments to be performed for quantitation of glycans by mass spectrometry.
Revolutionize Your UHPLC Experience
The Vanquish UHPLC system takes biomolecule separations to a new level. The system offers better, faster, separations than previously possible. The system has exceptional control and stability giving you unrivalled reproducibility for meaningful answers.
• Maximized separation power, flow and gradient precision• Controlled separations with reproducible thermostatting• Analyze more samples with Vanquish Charger module• Compliant Thermo Scientific™ Chromeleon™ CDS software
GlycanPac AXH-1 & AXR-1 ColumnsThermo Scientific™ GlycanPac™ AXR-1 and GlycanPac AXH-1 columns are high-performance, silica-based HPLC columns designed for high-resolution glycan separations. They provide industry-leading resolution with unique selectivities for biologically important glycans, either labeled or native, using fluorescence and/or mass spectrometry (MS) detection. Both columns separate glycans by charge and size. Additionally the GlycanPac AXR-1 columns are superior for separating glycan isomers. The GlycanPac AXH-1 columns are also used for fast, accurate, and simple quantification of glycans by charge.
8
Characterize Free GlycansYou can predict the structure of released labelled or unlabelled glycans using tandem mass spectrometry together with SimGlycan® (PREMIER Biosoft). The software automatically matches experimental mass spectra against a comprehensive database and generates a scored list of candidate structures.
ANALYZE & QUANTIFYSeparate and detect unlabeled, fluorescence labelled or glycans.
2 Minutes
Fluo
resc
ence
Cou
nts
3010 20
1 2
3
7
4
5
6
8
9
10
11
12 1415
16
neutral
monosialylated
13 170
8.5E5
Separation of labeled N-glycans from human IgG using a GlycanPac AXH-1 column.
High performance anion-exchange chromatography with pulsed amperometric detection (HPAE-PAD) is a well-established analysis method to characterize released Glycans. The separation is exceptionally selective for sugars and resolves glycans based on charge, size, composition, isomers and linkages. It is even possible to separate glycans based on sialic acid linkage, providing valuable information not only about the sugar sequence of a glycan, but also the subtle linkage differences that may indicate disease states.
INTACT GLYCOPROTEINIsolated antibody or glycoprotein.
INTACT GLYCOPROTEINIsolated antibody or glycoprotein.
RELEASE GLYCANSGlycans are released enzymatically using glycosidase.
RELEASE GLYCANSGlycans are released enzymatically using glycosidase.
RELEASE MONOSACCHARIDESGlycans are released enzymatically using glycosidase. Glycans are then hydrolyzed to monosaccharides using acid.
11
COMPLEX GLYCANS ARE attached to my drug?
IS THE COMPOSITION OF sugars in my drug entity?
WHICH TYPES OF WHAT
Label-free Glycan Workflow Monosaccharide Workflow
10
HPAE-PAD
Unique CarboPac ChemistryResins of Thermo Scientific™ CarboPac™ columns consist of nonpourous beads covered witrh a fine latex of functionlized Thermo Scientific™ Dionex™ MicroBead™. This pellicular resin structure permits excellent mass transfer, resulting in high resolution chromatography and rapid reequilibration.
Highly Crosslinked Core
Latex MicroBeads with Anion Exchange Functionalities
Monosaccharide composition, namly Fucose, Galactosamine, Glucosamine, Galactose, Glucose and Mannose, is routinly determined as their number and composition bound to the protein can impact efficacy of biotherapeutics. Monosaccharides are weak acids and can be separated by anion-exchange chromatography under basic conditions. Samples are acid hydrolyzed to release monosaccharides and analyzed by HPAE-PAD after chromatographic separation with CarboPac columns.
ANALYZE USING ION CHROMATOGRAPHYSimple, sensitive glycan analysis without labelling.
0 5 10
90
nC
–5
100
nC
–50 5 10
Minutes
1
2
3
45
6
1
2
3
4 5
6
A Without Dionex BorateTrap Column
B With Dionex BorateTrap Column
The Thermo Scientific™ Dionex ICS-5000+ and ICS-4000 HPIC™ systems are ideal for HPAE PAD ion chromatography of mono-, di-, polysaccharides and sialic acids. With completely metal free flowpaths we eliminate the possibility of metal contamination and improve robustness for biomolecules. The analysis can be performed using Reagent-Free™ IC (RFIC™) systems with eluent generation that only require deionized water to electrolytically generate the eluent.
HPAE-PAD only detects those compounds that contain functional groups that become oxidized at the detection voltage employed. Detection is sensitive and highly selective for sugars, because many potentially interfering species cannot be oxidized or reduced, and are not detected.
High Performance Ion Chromatography™ for HPAE-PAD
ANALYZE USING ION CHROMATOGRAPHYUltra sensitive monosaccharide and sialic acid analysis.
0 5 10
90
nC
–5
100
nC
–50 5 10
Minutes
1
2
3
45
6
1
2
3
4 5
6
A Without Dionex BorateTrap Column
B With Dionex BorateTrap Column
0 5 10
90
nC
–5
100
nC
–50 5 10
Minutes
1
2
3
45
6
1
2
3
4 5
6
A Without Dionex BorateTrap Column
B With Dionex BorateTrap Column
25
150
nA A
Minutes
0 10 20 30 40 50
25
300
nA B
25
150
nA A
Minutes
0 10 20 30 40 50
25
300
nA B
Free unlabelled N-Linked Oligosaccharides from Monoclonal Antibody Preparations.Chromatograms:A: PNGase F digest of human polyclonal IgG B: PNGase F digest of humanized MAB M115
BR64513-EN 0515S
Join the Sweet Revolution in Biopharmaceuticals visit www.thermoscientific.com/sweetrevolution
facebook.com/ChromatographySolutions twitter.com/ChromSolutions analyteguru.com
Denmark +45 70 23 62 60Europe-Other +43 1 333 50 34 0Finland +358 10 3292 200France +33 1 60 92 48 00Germany +49 6103 408 1014India +91 22 6742 9494Italy +39 02 950 591
Africa +43 1 333 50 34 0Australia +61 3 9757 4300Austria +43 810 282 206Belgium +32 53 73 42 41Canada +1 800 530 8447China 800 810 5118 (free call domestic)
400 650 5118
Japan +81 45 453 9100Korea +82 2 3420 8600Latin America +1 561 688 8700Middle East +43 1 333 50 34 0Netherlands +31 76 579 55 55New Zealand +64 9 980 6700Norway +46 8 556 468 00
Russia/CIS +43 1 333 50 34 0Singapore +65 6289 1190Spain +34 914 845 965Sweden +46 8 556 468 00Switzerland +41 61 716 77 00UK +44 1442 233555USA +1 800 532 4752
www.thermoscientific.com/glycomics©2015 Thermo Fisher Scientific Inc. All rights reserved. SimGlycan is a registered mark of PREMIER Biosoft International, USA. All other trademarks are the property of Thermo Fisher Scientific and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.
Stay Ahead! Scan the QR code or follow the URL to watch the latest webinars on glycan characterization.