John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf ·...

24
John Cantor Heat Pumps Ltd www.heatpumps.co.uk Author Heat Pumps for the Home (Crowood press) Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015

Transcript of John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf ·...

Page 1: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

John Cantor Heat Pumps Ltdwww.heatpumps.co.uk

AuthorHeat Pumps for the Home

(Crowood press)

Ground Source Energy Expo 2015The Ricoh Arena, Coventry10 September 2015

Page 2: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Monitoring

Introduce performance monitoring / energy monitoring

Why?

Who benefits?

Examples

Page 3: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

What is Monitoring

Collect operational data

• Operating temperatures• Power consumption• Heat output

Display on a website

Page 4: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Why Monitor Heat Pumps?

The entire heat pump system is complicated

Heat pumps transfer heat from one place to another

Heat pumps are fundamentally different from any other heating technology

Page 5: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

• Ground source size, depth and fluid circulation• The heat pump unit• Distribution of heated water• Emitter system (underfloor or radiators)• Domestic hot water

• The type of house and way it is used• User controls

DON’T PANIC!

Why Monitor Heat Pumps?

Page 6: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Lower water temperatures improve energy efficiency

Page 7: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Energy efficiency v Output temperature

Degrees C

COP

Operating the system at its best efficiency

Page 8: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Installer/ designer

Ensure the system is operating correctly

Can learn what designs work best

Can alert potential issues as they develop

Home owner

Learn how to set the system for best effect

Check running costs and operation

Who Benefits?

Page 9: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

https://www.recc.org.uk/rhi/mmsp

Pays the home owner £230/year (for 7 years)

Contract between MCS installer and the customer

Capped at 10,000 applicants this year

Metering and Monitoring Service Package

https://www.ofgem.gov.uk. (Search MMSP)

Page 10: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

https://www.ofgem.gov.uk. (Search MMSP)

Page 11: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

MMSP compliant monitoring systems

Dashboard

Hardware

http://www.melcloud.com/

Page 12: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Data stored on a website

Viewable from any computer

http://www.openenergymonitor.org/emon/

Open source

Dashboard exampleOpenEnergyMonitor

Very adaptable

Steep learning curve

Page 13: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

1) Electrical power input

Pulsemeasurement

CT clampsWithVoltagesensing

Page 14: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

2) Temperatures

Heat meter sensorIn pocket

Room temperature transmitter

Page 15: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

3) Heat output

Water (glycol) flow rate& temperature difference

KamstrupSontex

Heat Meters

Page 16: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Simple dashboard for home owner

Page 17: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Ground source inverter heat pump40 minute run period to underfloor heating

Page 18: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Ground source heat pump30 minute run periods to underfloor heatingFlow-return dt’s good, flow rates goodGround coil below zero!

Page 19: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Domestic hot water

Yellow area = input energy

53°C

40°C

COP 3.5 COP 2.8

Analysis for engineer

d.t.50°C

Indicating an average COP over heating period of over 3

Watts, °C

Page 20: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Domestic hot water

60°C

48°C55°C

Page 21: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

What can we glean?

Temperature difference (flow-return) tells us whatthe liquid flow-rate is.

Is pipework sized correctly?

Is there a blocked filter? Is the pump speed set correctly?

Is the compressor cycling reasonably?

Can the heating curve be lowered?

Are there unnecessary DHW charge periods?

Is standby power reasonable?

Page 22: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

To heating circuits

From ground loops

Refrigerant circuit analysis

Page 23: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Heat pump controller’s COP/SPF calculator

Input powerHeat outputCOP

Refrigerant data

Page 24: John Cantor Heat Pumps Ltd Author Heat ...gshp.org.uk/Conference2015/Domestic_GSHP_design.pdf · Ground Source Energy Expo 2015 The Ricoh Arena, Coventry 10 September 2015. Monitoring

Thank You

www.recc.org.uk/rhi/mmspwww.ofgem.gov.uk. (Search MMSP)

www.openenergymonitor.org/emon/

http://johncantorheatpumps.blogspot.co.uk/