    EXPERIMENTAL STUDIES OF A DOUPIPE HELICAL HEAT EXCHANGE

    Guided By :

    AJAI M

    ASST.PROFESSOR

    Dept. of ME

    MCET

    Presented By :

    JISHNU

    S7 ME

    Roll No

    MCET

  • 8/11/2019 jishnu COPY

    3/23

    INTRODUCTION

    Helically coiled tubes are superior to straight tubes

    Development of secondary flows due to centrifugal force enh

    heat transfer

    Two major boundary conditions: constant wall temperature a

    constant heat flux

    The outer wall of the annulus will be insulated

  • 8/11/2019 jishnu COPY

    4/23

    Poor circulation of fluid could be avoided using a double pip

    configuration

    The temperature of the inner wall of the annulus will be dict

    by the fluid temperature in the inner tube

  • 8/11/2019 jishnu COPY

    5/23

    OBJECTIVE

    Design, build and instrument two double-pipe helical heat ex

    The difference between the two being the size of the inner tu

    Experimentally evaluate the heat transfer characteristics of a

    pipe helical heat exchanger for both parallel flow and counte

    configurations

    Compare the experimental results

  • 8/11/2019 jishnu COPY

    6/23

    MATERIALS AND METHODS

    Heat exchanger

    Constructed from copper tubing

    Outer tube of heat exchanger had an outer dia of 15.9mm

    Wall thickness of 0.8mm

    Inner tube had an outer dia of either 9.5mm or 6.4mm

    Each coil had a radius of curvature of 235.9mm

  • 8/11/2019 jishnu COPY

    7/23

    EXPERIMENTAL APPARATUS

    Cold tap water is used for the fluid flowing in the annulus

    A large reservoir and a submersible pump was used to flow t

    annulus

    Flow was controlled by a flow meter with an attached meteri

    Hot water for the inner tube was set at 60 degree Celsius

  • 8/11/2019 jishnu COPY

    8/23

    EXPERIMENTAL APPARAUS(CONTIN

    Flow rate of inner tube was controlled by an identical flow m

    metering valve

    Flexible PVC tubing was used for all connections

    Type k thermocouples are used to measure the inlet and outle

    temperatures for both fluid

    Temperature data was recorded using a data acquisition conn

    computer

  • 8/11/2019 jishnu COPY

    9/23

  • 8/11/2019 jishnu COPY

    10/23

  • 8/11/2019 jishnu COPY

    11/23

    EXPERIMENTAL PROCEDURE

    Flow rate in the annulus and in the inner tube were varied

    Following five levels were used: 100, 300, 500, 700, 900cm

    These were done for both coils and in parallel flow and coun

    configurations

    Three replicates were done for every combination of flow ra

    size and configuration

  • 8/11/2019 jishnu COPY

    12/23

    CALCULATION OF HEAT TRANSFCOEFFICIENTS

    Overall heat transfer coefficient was calculated from the tem

    data

    Heat transfer coefficients for the annulus and for the inner tu

    calculated using traditional Wilson plots

    Method was chosen to avoid the disturbance of flow patterns

    transfer while attempting to measure wall temperatures

  • 8/11/2019 jishnu COPY

    13/23

    Generated by calculating overall heat transfer coefficients w

    fluid kept constant and other varied

    Flow in the inner tube was kept constant and the flow in the

    was varied for the five different flow rates.

  • 8/11/2019 jishnu COPY

    14/23

    CALCULATION OF HEAT TRANSFCOEFFICIENTS

    Uo = Overall heat transfer coefficient

    Q = Heat transfer rate

    Ao = Surface area

    LMTD = Log mean temperature difference

  • 8/11/2019 jishnu COPY

    15/23

    RESULTS AND DISCUSSION

  • 8/11/2019 jishnu COPY

    16/23

  • 8/11/2019 jishnu COPY

    17/23

  • 8/11/2019 jishnu COPY

    18/23

  • 8/11/2019 jishnu COPY

    19/23

  • 8/11/2019 jishnu COPY

    20/23

  • 8/11/2019 jishnu COPY

    21/23

    CONCLUSION

    Little difference between the overall heat transfer coefficient

    parallel flow and counter flow configurations.

    Heat transfer rates were much higher in the counter flow con

    due to the larger average temperature difference between the

    fluids.

    Nussult number in the annulus was compared to the numeric