Jiaru Shi(Department of Engineering Physics, Tsinghua University) Hao Zha (CERN) 2014.02.04 CLIC...

Click here to load reader

download Jiaru Shi(Department of Engineering Physics, Tsinghua University) Hao Zha (CERN) 2014.02.04 CLIC Workshop 2014 CLIC choke mode structure and X-band activities.

of 22

Transcript of Jiaru Shi(Department of Engineering Physics, Tsinghua University) Hao Zha (CERN) 2014.02.04 CLIC...

  • Slide 1

Jiaru Shi(Department of Engineering Physics, Tsinghua University) Hao Zha (CERN) 2014.02.04 CLIC Workshop 2014 CLIC choke mode structure and X-band activities in Tsinghua University. Slide 2 Outline Review of Choke mode design RF measurement Wakefield experiment On progressing and future plan Other X-band activities at Tsinghua last year Acknowledgment Collaboration with CLIC study Collaboration with AWA (ANL) and Euclid Lab. Accelerating Group in Tsinghua Slide 3 Overview of CDS design NameDescriptionParametersManufactory & Measurement CDS-AOriginal design; regular choke; Prototype cells made in CERN CDS-BHOM tuned choke; Wakefield suppression Improve; No CDS-CNew choke design, Optimized on wakefield suppression; Prototype cells (aluminium) made in Tsinghua. Wakefield tested in AWA(ANL). CDS-DNew choke design; Optimized on RF parameters. No Slide 4 New choke design (CDS-C) Improved features include: Two section design: avoid parasitic mode (~30GHz) Thin-neck design and matching design: reduce reflection of HOMs from choke. Dipole detuning design: detune two low-band dipole modes in one cell 1.6mm 1.2mm 2.0mm S 11 S 12 Absorbed by load Slide 5 Damping result Freq( GHz) Q(R/Q ) 15.75.480.3 18.66.963.2 23.73.814.8 28.412.410.9 38.211.69.9 sCDSWDS FcFc 11 F rms 45 F worst 2520 W (s=0.15m) Beam dynamic requirements < 6.6 WDS5 CDS-A20~30 +Two section & Thin- neck 10~17 +Matching step7~10 +Dipole detuning (CDS-C) 5~6 Experimental results. Click here Slide 6 From CDS-C to CDS-D Optimized on distributions of iris size on each cell. Using genetic algorithm. W (0.15m)~4V/pC/m/mm; F c =1.01; F rms =3.8; F worst =35. CDS -C CDS -D CLI C-G Iris aperture(mm)3.15, 2.35 3.49, 2.50 3.15, 2.35 Iris thickness(mm)1.67, 1 1.7, 1.48 1.67, 1 Shunt impedance(M/m) 59, 83 53, 74 81, 103 Group velocity(%c) 1.38, 0.73 2.00, 0.75 1.65, 0.83 Bunch population ( 10 9 ) 3.724.503.72 Max E- field(MV/m) 246223235 Sc* (MW/mm^2)5.725.175.45 Pulse heating(K)23.222.047.9 Peak input power(MW) 67.479.360.2 Filling time(ns)72.460.862.2 RF-beam efficiency (%) 24.226.028.1 * Reference: Phys. Rev. ST Accel. Beams 12, 102001 (2009) Slide 7 From CDS-C to CDS-D CDS -C CDS -D CLI C-G Iris aperture(mm)3.15, 2.35 3.49, 2.50 3.15, 2.35 Iris thickness(mm)1.67, 1 1.7, 1.48 1.67, 1 Shunt impedance(M/m) 59, 83 53, 74 81, 103 Group velocity(%c) 1.38, 0.73 2.00, 0.75 1.65, 0.83 Bunch population ( 10 9 ) 3.724.503.72 Max E- field(MV/m) 246223235 Sc* (MW/mm^2)5.725.175.45 Pulse heating(K)23.222.047.9 Peak input power(MW) 67.479.360.2 Filling time(ns)72.460.862.2 RF-beam efficiency (%) 24.226.028.1 CDS-C CDS-D * Reference: Phys. Rev. ST Accel. Beams 12, 102001 (2009) Slide 8 RF measurements Radial line experiments are applied to: test the reflection of RF load (SiC pieces) verify HOMs absorption in choke structure Calibration using multi-short load (> 3). To VNA Place RF load S 11 S 12 absorbed in the load Slide 9 Radial line experiments Using Agilent E8364B VNA,10MHz~50GHz. (Equipments supported by Department of Electronic Engineering, Tsinghua University) Calibration error and results Slide 10 Reflection of RF load Material EcasicP, provide by CERN. Results are promising (lower than -20dB). a=b=9.5mm,c=0.1mm Slide 11 HOMs absorption in choke Frequency of Parasitic mode Matching steps Increase the absorption Slide 12 Wakefield experiment at AWA(ANL) G2 (Witness) beam line: 15MeV, 1~100nC G3 (Drive) beam line: 75MeV, >100nC Can produce Bunch train G1 beam line: laser trigger breakdown experiment 1#2#3#4# oscilloscope Slide 13 Set up experiments GUNLINAC Chamber ICT Spectr omete r G2 Beam line set up for CLIC-choke-mode experiments Be windows 50.4um thickness For 14MeV electron beam, ~30% (calculated by Fluka) of the beam can pass it without any scattering. Optimized on beam dynamics: 1nC Beam size: ~0.7m, 5nC Beam size: ~1.6m, Beam aperture: 5.5mm Slide 14 Set up experiments Aluminium cells, SiC load (reproduced in U.S.). Coaxial RF cable (0.59mm outer radius, magnetic probe) 20GHz oscilloscope, 0~20GHz mixer Slide 15 Experimental results Low-band Dipole mode at 16GHz and 19GHz16GHz and 19GHz Looks like the dipole mode at 50-22= 28GHz Fundamental modeUnidentified Q (@12GHz)=160~400 Q (@16GHz)=12.5 Q (@19GHz)=15.3 Signal of cable 3#; 10dB Attenuator, No mixer; Frequency and Q results are good! Slide 16 On progressing and future plan Single cell SW structure to test breakdown behavior in the choke. Hope to tested in KEK. 6-cell choke-mode structures with tuning manufacturing in Tsinghua. Full structure for high-gradient test will be developed later. Two beam experiments? Slide 17 X-band structure assembly in Tsinghua T24 pieces from CERN; Bonding and brazing (testing): Vacuum leak tested OK! Assembly and Tuning (Later) Slide 18 An X-band (Copper) Power Extractor for ANL Slide 19 Infrastructure update for X-band Cleaning room for high gradient structure (plus a new 40GHz VNA); Upgrade of H-furnace for brazing: More precisely control for temperature in real time. Slide 20 Thank you Slide 21 Multiple short Calibration x:refl. from coaxial (measured) y:refl. from radial line (calc.) s11,D,s22: to be solved Slide 22 Wakefield measurement results L0L0 No Mixer CABLEAttenuati on 1#30 dB 2#20 dB 3#10 dB 4#0 dB