Product Description JETSET™ Outlet Points for Oxygen and Fuel Gases 1 3 2 6 5 4 7 8 9 Description The JETSET TM outlets for safe and reliable gas distribution make gases available when and where they are needed. The outlets are easy to service and are designed for oxygen and fuel gases. The JETSET TM outlets can be combined for various purposes and can be mounted as single or twin outlets. The JETSET TM outlets consist of the following parts: Valve unit Ball valve, easy to see if in open or closed position. It is easy to service as the filter is placed below the valve. It has conical sealing of inlet pipes for welding and brazing. Regulator UNICONTROL TM 700 has high capacity, is easy to adjust and easy to service. The same basic design as for other UNICONTROL TM regulators. Flashback arrestor For acetylene/propane or oxygen. The FR-50/Safe-Guard-4 TM is a multi-functio- nal safety device with the following 4 functions: check valve, flame filter, pressure sensitive cut-off valve, and thermal cut-off valve. Check valve For oxygen or fuel gases. The pictures show how the outlets are equipped, the signs that show LH threads or colour are not correct on all pictures.

Transcript of JETSET™ Outlet Points for Oxygen and Fuel Gases€¦ · JETSET™ Outlet Points for Oxygen and...

Product DescriptionJETSET™ Outlet Points for Oxygen and Fuel Gases

1

3

2

65

4

7 8

9

Description

The JETSETTM outlets for safe and reliable gas distribution make gases available when and where they are needed. The outlets are easy to service and are designed for oxygen and fuel gases. The JETSETTM outlets can be combined for various purposes and can be mounted as single or twin outlets.

The JETSETTM outlets consist of the following parts:

Valve unit Ball valve, easy to see if in open or closed position. It is easy to service as the filter is placed below the valve. It has conical sealing of inlet pipes for welding and brazing.

Regulator UNICONTROLTM 700 has high capacity, is easy to adjust and easy to service. The same basic design as for other UNICONTROLTM regulators.

Flashback arrestor For acetylene/propane or oxygen. The FR-50/Safe-Guard-4TM is a multi-functio-nal safety device with the following 4 functions: check valve, flame filter, pressure sensitive cut-off valve, and thermal cut-off valve.

Check valve For oxygen or fuel gases.

The pictures show how the outlets are equipped, the signs that show LH threads or colour are not correct on all pictures.

2

JETSETTM Single Outlet Points for Oxygen, Acetylene, Hydrogen and Propane.

JETSETTM Twin Outlet Points for Oxygen/Acetylene and Oxygen/Propane.

Welding, cutting and heating operations require outlets for acetylene, propane as well as oxygen. To make the installation as simple as possible, it is recommended to have a JETSETTM Twin Outlet Point installed. The JETSETTM twin outlets are available in five versions to meet the customers’ need.

Article Numbers and Technical Data

Article No. JETSET

Twin outlet

Item No.

GasInlet connection

for welding to 14 mm steel pipe

Inlet connection for brazing to 12 mm copper pipe

Outlet G3/8

Working pressure

(bar)

203 310 235 4O2

C2H2

XRH LH

0-10 0-1,2

203 310 236 6O2

C2H2

XRH LH

0-10 0-1,2

203 310 237 8O2

C2H2

XRH LH

0-10

203 310 238 2O2

C2H2

XRH LH

0-10 0-1,2

203 310 261 4O2

C3H8

XRH LH

0-10 0-5

JETSET single outlets for fuel

gases

203 310 239 7 C2H2 X LH 0-1,2

203 310 240 3 C2H2 X LH 0-1,2

203 310 241 5 C2H2 X LH

203 310 269 1 H2 X LH 0-10

203 310 270 1 C3H8 X LH 0-5

JETSET single outlet for oxygen

203 310 268 1 O2 X X RH 0-10

203 310 273 3 O2 X X RH 0-10

JETEX 215 190 920

9 O2

Steel pipe 21,3x3,1 mm

Copper pipe 15 mm ext. 20 mm int.

M28x2 RH 2-16

3

JETSET Outlet Points Consist of the Following Parts

JETSET Article No.

Valve UnitUNICONTROL ™ 700 Oxygen

UNICONTROL ™ 700 Acetylene

UNICONTROL ™ 700 Hydrogen

UNICONTROL ™ 700 Propane

203 310 235 203 010 741 203 005 306 203 005 307

203 310 236 203 010 458 203 005 306 203 005 307

203 310 237 203 010 741 203 005 306

203 310 238 203 010 741 203 005 306 203 005 307

203 310 239 203 010 457 203 005 307

203 310 240 203 010 740 203 005 307

203 310 241 203 010 740

203 310 273 203 010 456 203 005 306

203 310 269 203 010 740 213 003 280

203 310 270 203 010 740 203 005 308

203 310 261 203 010 741 203 005 306 203 005 308

203 310 268 203 010 456 203 005 306

215 190 920 R 64 J

JETSET Article No.

SAFE-GUARD-4 Oxygen

SAFE-GUARD-4 Acetylene

Non-return valve

203 310 235 203 011 136 215 191 097

203 310 236

203 310 237 203 011 136 215 191 097

203 310 238 203 011 137 203 011 136

203 310 239

203 310 240 203 011 136

203 310 241 203 011 136

203 310 273 203 011 137

203 310 269 215 191 102

203 310 270 215 191 102

203 310 261 203 011 136 215 191 097

203 310 268 215 191 097

215 190 920

GCE Norden ABBox 210 44, SE-200 21 Malmö, Sweden

Telephone +46 40 38 83 00 Telefax +46 40 38 83 53www.gcenorden.se

Distributed by:GCE Norden AB

GCE Norden AB undertakes a continuous programme of research and development and therefore reserves the right to make alterations in design and specifications without prior notice.

Product description 700 215 029

0510

14jh

h

Article Numbers

Article No Adaptors for Old Shut-off Valves

202 011 119 AGA ball valve Oxygen/Acetylene

202 011 120 AGA diaphragm valve Oxygen

202 011 121 AGA diaphragm valve Acetylene

Spare Parts Lists

700 215 055 JETSET™ Valve units 700 215 111 Regulator UNICONTROLTM 700 700 215 067 Jetex outlet

Recycling

The material in the JETSET™ outlet points shall be recycled by scrapping at an authorized scrapping firm.

Flow Charts