JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf ·...
Transcript of JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf ·...
![Page 1: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/1.jpg)
All primary influent and effluent channels covered
Two sludge holding tanksare coveredCarbon adsorber
for odor control
JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW
Exhaust fan for activated sludgediffusion of odors
![Page 2: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/2.jpg)
JEFFERSONTOWN ODOR CONTROL PROJECT SUMMARY
• Two Phase odor control project
• Total spent by MSD during 3 years is $600,000
• Last project successfully completed in October, 2003
Odor specialists with Webster Environmental Assoc.and CH2MHill initially conducted a study and developed a
Master Odor Control Plan for the facility
![Page 3: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/3.jpg)
CHEMICAL FEED SYSTEMS INSTALLED AT PUMP STATIONS
• Lakelet Way and Chenoweth Run Pump Stations were major contributors of odorous hydrogen sulfide
• Chemicals (Bioxide) help control odors from manholes outside plant boundaries as well
![Page 4: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/4.jpg)
RAW SEWAGE CHANNELS AND SLUDGE HOLDING TANKS WERE COVERED TO CONTAIN ODORS
![Page 5: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/5.jpg)
CARBON ADSORBER USED TO TREAT ODORS FROM SLUDGE HOLDING TANKS
• Carbon is often used to physcially remove odors from wastewater treatment plant processes
• This unit was tested and removes 99.8% of hydrogen sulfide and 94% of odor emissions
![Page 6: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/6.jpg)
ACTIVATED SLUDGE DIFFUSION EFFECTIVELY TREATS RAW SEWAGE ODORS
• Air is pulled from under channel covers with an exhaust fan
• Odorous air is diffused into the activated sludge process for effective treatment with 97.6% removal of hydrogen sulfide
![Page 7: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/7.jpg)
MSD MODIFIED IT’S OPERATION TO REDUCE ODOR EMISSIONS
• MSD changed the operation of the plant process to reduce odor emissions from the secondary aeration basins
• Plant performance has not been compromised as a result
![Page 8: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/8.jpg)
00.20.40.60.8
11.21.4
Poun
ds p
er d
ay
Hydrogen Sulfide
Hydrogen Sulfide Emissions are reduced by 76% as a result of
odor control project
BeforeAfter
Jeffersontown WWTPHydrogen Sulfide Emissions
![Page 9: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/9.jpg)
02,000,0004,000,0006,000,0008,000,000
10,000,00012,000,000
OE
R (c
fm*D
T)
Odor EmissionRate
Odor emissions are reduced by 78% as as result of the
odor control project
BeforeAfter
Jeffersontown WWTPOdor Emissions
![Page 10: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/10.jpg)
ODOR MODELING USED TO SHOW RESULTS……
Models predict peak dilutions to threshold (DT) and the frequency
(hours per year) with which they occur
![Page 11: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/11.jpg)
Taylorsville Rd.
Ruckriegel P
kwy.
Axis
Chenoweth Run
Sou RR
Rehl
Watterso
n Trail
CommunityCenterPark
JT WWTP
J'town WWTPPeak D/T Contours
Existing Plant
Notice peak DT contour of 50in residential area beforeodor control implemented
![Page 12: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/12.jpg)
Taylorsville Rd.
Ruckriegel P
kwy.
Axis
Chenoweth Run
Sou RR
Rehl
Watterso
n Trail
CommunityCenterPark
JT WWTP
J'town WWTPPeak D/T Contours
After Odor Control Improvements
Notice peak DT contour reduced to 10(very faint odor) in residential area after odor control implemented
Modeling shows significantimprovement in odors in the neighborhoods as a resultof odor control project
![Page 13: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/13.jpg)
Taylorsville Rd.
Ruckriegel P
kwy.
Axis
Chenoweth Run
Sou RR
Rehl
Watterso
n Trail
CommunityCenterPark
JT WWTP
J'town WWTPEvent ContoursExisting Plant
No O.C. on SHTBaseline
Notice that odors could have occurredfrequently before the odor control project up to 1000 times per year in the residential areas
![Page 14: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/14.jpg)
Taylorsville Rd.
Ruckriegel P
kwy.
Axis
Chenoweth Run
Sou RR
Rehl
Watterso
n Trail
CommunityCenterPark
JT WWTP
J'town WWTPFrequency Contours (Hrs/Yr > 7 D/T)
After Odor Control Improvements
Notice that frequency contoursReduced to 100 times per yearFor a faint odor detection
![Page 15: JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR …msdlouky.org/programs/pdfs/jtown04.pdf · JEFFERSONTOWN WASTEWATER TREATMENT PLANT ODOR CONTROL PROJECT OVERVIEW ... wastewater treatment](https://reader030.fdocuments.in/reader030/viewer/2022011800/5ad606a77f8b9a177c8dbb1e/html5/thumbnails/15.jpg)
MSD MEETS ODOR CONTROL GOALS FOR J’TOWN WWTP
• Successful odor control project has eliminated, or at the very least, significantly reduced odor
complaints to comply with MSD’sGood Neighbor Policy