Jai saini port folio
description
Transcript of Jai saini port folio
FFLTOS
+87.55
Fixed glazing
Roof projectionabove
2.2 mt. WIDECORRIDOR
FHC
SITEBOUNDARY
WALL
SITEBOUNDARY
WALL
FFLTOS
-150 As/struc.
PLOT BOUNDARYWALL
5000
5000
ARRIVALCOURT
3110
3680
FFLTOS -75
SITEBOUNDARY
SH-G-02
SH-G-03
SH-G-04
SH-G-05
SH-G-07
SH-G-11
SH-G-10
1555
1581
ST
UD
EN
TC
YC
LE P
AR
KIN
G
60001500
3400
VIE
WIN
G G
ALL
ER
YF
OR
SW
IMM
ING
PO
OL
UP
SWIMMING POOLBOUNDARY WALL
5000
5000
VOLLYBALLCOURT
D3a
D3a
D6
W4W5W4
W6W6
SH-G-06
2.3 mt. WIDECORRIDOR
SH-G-10
5110
6750
6750
6750
2940
7630
FFLTOS
+87.55
FFLTOS
+87.55
FFLTOS
+87.7
FFLTOS
+87.55
FFLTOS
+87.2
+87.7
+87.7
+87.7
+87.7
+87.7
+87.7+87.7
FFLTOS
+87.400
450
FFLTOS
+87.55
Center Lineof Building
FFLTOS
+88.000
FFLTOS
+87.55
FFLTOS
+87.55
FFLTOS
+87.55
E
X
IS
T
IN
G
R
O
A
D
FFLTOS
+87.7
FFLTOS
+87.55
FFLTOS
+87.55
START= 87.55END=89.00
FFLTOS
+87.7
FFLTOS
+87.7
FFLTOS
+87.1
FFLTOS
+87.55FFLTOS
+87.55
ENTRY FORVEHICLES
(CRICKET FIELD)
ENTRANCE
LANDSCAPEAS/DETAILS
LANDSCAPEAS/DETAILS
FFLTOS
+87.7
E
X
IS
T
IN
G
R
O
A
D
E
X
IS
T
IN
G
R
O
A
D
CUSHION BOARDS ON WALL
CUSHION BOARDS ON WALL
CU
SH
ION
BO
AR
DS
ON
WA
LL
CU
SH
ION
BO
AR
DS
ON
WA
LL
A
1 2 3 4 5 6 7 8
5000
0
1 2 3 4 5 6 7 8
2500 2500 2500 2500 2500 2500 2500 2500 2500 2500
300350
5000
0
Openable cover(metal) hatch forequipment maintenence
FFLTOS -75
+16
50 m
mA
s/st
ruc.
Drain channelas/detail
200
1000
200
385
00
1727
27
2100
D4
0301
A
LOUVERS IN WALL AS/HVACDWG. AT BEAM SOFFIT
PEDESTRIANENTRY
FHC
SERVICE ENTRY(6 mt. WIDE)
PEDESTRIANENTRY
PROPOSEDROAD
SERVICEENTRY
TENDER DRAWING
SITE PLAN
SH-AR-100JS
1:250
NOTES
ARCHITECTS & PLANNERS
CLIENTS
- Dimensions are not to be scaled.- All Dimensions are in Millimeters unless statedotherwise.- All Levels are in Millimeters and relate to ...........Datum level.- The contractor shall verify all dimensions,details,specifications &site conditions & shall report any error, omissionand/or anomaly tothe architect before commencement of work.- For construction purposes, the dimensions shall notbe measureddirectly of the drawings. The drawings shall not beused forconstruction until they are issued for construction.-These drawings are to be read in co-ordination withhvac,electrical, plumbing drawings & all relevant sections ofspecifications..-All shop drawings should be provided to the architectfor approval.
Job Title
Drawing Title
Architect's Signature
Document Release Type
Revision No.
Drawing No.
Drawn by
Job No.
A U T H O R I T Y :
Scale
Date
Checked by
ARCOP ASSOCIATES PVT. LTD.E-106, G.K. ENCLAVE PART 1NEW DELHI 110048PHONE : 011 - 26242050FAX : 011 - 26242035
Indian Institute of Technology(IIT) Indore,Institute of Engineering and Technology, DAVV Campus,Khandwa Road, Indore 452017Madhya Pradesh, India
1. VENDORS TO PROVIDE SHOP DRAWINGS FOR THE APPROVALFROM THE ARCHITECT.
Client's Signature
ISSUES
REVISIONDATE DESCRIPTION
R0PS
STRUCTURAL CONSULTANT
ELECTRICAL &HVAC CONSULTANTMJ ConsultantsNEW DELHI 110020
MKG ConsultantsNEW DELHI 110020
PLUMBING & FIRE FIGHTING
PMC's Signature
PROJECT MANAGERMECON LIMITEDRANCHI-834002, JHARKHAND, INDIA.TEL :0651-2483440,2481707
IITI INDOOR SPORTS CENTER
NOV 01, 2012
Technical Projects ConsultantsNew Delhi-110025 (India)
2012/18
IIT
IND
OR
E
Key Plan:
INDOOR SPORTS CENTER
IIT
IND
OR
E
SQUASH - 29800x6450
D1
D1
D1
FFLTOS
-4050-4170
-405
0-4
170
Foldable/fixedbleechers
SERVICE ROOM4.5 x 4.8 mt.
EQUIP-28.0 X 2.8 mt.
EQUIPMENT-13 X 8.7 mt.
Building extent onground floor
9800
310048904890 4890
6450
SQUASH - 19800x6450
SQUASH - 39800x6450
X
FHC
D2
D2
11
5970
5110
6750
6750
6750
2940
7630FFL
TOS-3400-3475
Building extent onground floor
Up
1
7630
2100
5000
3100 4890 4890
PUMP ROOM17855 X 7830
A'
FFLTOS
VARIES-3000
Hatch above 3000X2500
Compactedearth (As/specs)
Cut out 1000X750 mm-300mmbelow from bottom of slab
Manhole cover as/specs.
PVC Run ladder 300mm C/C as/specs.
PVC Run ladder 300mm C/C as/specs.
7830
300 mm wide surface drain withperforated D.I cover on top
Electrical panel(floor mounted)
pump panel b.o.pipe-950mm
cable b.o.pipe-950mm
300 mm Wide swale As/plumbingdetail
300 mm Wide surface
drain as / plumbing
Compactedearth (As/specs)
14
A
0301
SH-B-01
SH-B-02
SH-B-05
SH-B-03
SH-B-07
SH-B-06
SC-02
SH-B-04
SC-01
SH-B-08
SH-B-09
Compactedearth (As/specs)
Compactedearth (As/specs)
CUTOUT IN WALL ATBEAM SOFFIT FOR FRESHAIR DUCT (750 X 350 MM)
5200
DOOR/WINDOW SCHEDULE:
TENDER DRAWING
FLOOR PLAN ATBASEMENT LEVEL
SH-AR-200JS
1:100
NOTES
ARCHITECTS & PLANNERS
CLIENTS
- Dimensions are not to be scaled.- All Dimensions are in Millimeters unless statedotherwise.- All Levels are in Millimeters and relate to ...........Datum level.- The contractor shall verify all dimensions,details,specifications &site conditions & shall report any error, omissionand/or anomaly tothe architect before commencement of work.- For construction purposes, the dimensions shall notbe measureddirectly of the drawings. The drawings shall not beused forconstruction until they are issued for construction.-These drawings are to be read in co-ordination withhvac,electrical, plumbing drawings & all relevant sections ofspecifications..-All shop drawings should be provided to the architectfor approval.
Job Title
Drawing Title
Architect's Signature
Document Release Type
Revision No.
Drawing No.
Drawn by
Job No.
A U T H O R I T Y :
Scale
Date
Checked by
ARCOP ASSOCIATES PVT. LTD.E-106, G.K. ENCLAVE PART 1NEW DELHI 110048PHONE : 011 - 26242050FAX : 011 - 26242035
Indian Institute of Technology(IIT) Indore,Institute of Engineering and Technology, DAVV Campus,Khandwa Road, Indore 452017Madhya Pradesh, India
1. VENDORS TO PROVIDE SHOP DRAWINGS FOR THE APPROVALFROM THE ARCHITECT.
Client's Signature
ISSUES
REVISIONDATE DESCRIPTION
R0PS
STRUCTURAL CONSULTANT
ELECTRICAL &HVAC CONSULTANTMJ ConsultantsNEW DELHI 110020
MKG ConsultantsNEW DELHI 110020
PLUMBING & FIRE FIGHTING
PMC's Signature
PROJECT MANAGERMECON LIMITEDRANCHI-834002, JHARKHAND, INDIA.TEL :0651-2483440,2481707
IITI INDOOR SPORTS CENTER
NOV 01, 2012
Technical Projects ConsultantsNew Delhi-110025 (India)
2012/18
IIT
IND
OR
E
Key Plan:
INDOOR SPORTS CENTER
IIT
IND
OR
E
FFLTOS
+87.55
Fixed glazing
Roof projectionabove
2.2 mt. WIDECORRIDOR
FHC
ARRIVALCOURT
3110
3680
FFLTOS -75
SH-G-02
SH-G-03
SH-G-04
SH-G-05
SH-G-07
SH-G-11
SH-G-10
1555
1581
1500
3400
5000
D3a
D3a
D6
W4W5W4
W6W6
SH-G-06
2.3 mt. WIDECORRIDOR
SH-G-10
5110
6750
6750
6750
2940
7630
FFLTOS
+87.55
FFLTOS
+87.7
FFLTOS
+87.55
+87.7
+87.7
+87.7
+87.7
+87.7
+87.7+87.7
450
FFLTOS
+87.55
Center Lineof Building
FFLTOS
+87.7
FFLTOS
+87.55FFLTOS
+87.55
LANDSCAPE
FFLTOS
+87.7
CUSHION BOARDS ON WALL
CUSHION BOARDS ON WALL
CU
SH
ION
BO
AR
DS
ON
WA
LL
CU
SH
ION
BO
AR
DS
ON
WA
LL
Openable cover(metal) hatch forequipment maintenence
FFLTOS -75
Drain channelas/detail
00
1727
27
2100
D4
0301
A
LOUVERS IN WALL AS/HVACDWG. AT BEAM SOFFIT
PEDESTRIANENTRY
FHC
SERVICE ENTRY(6 mt. WIDE)
SERVICEENTRY
TENDER DRAWING
FLOOR PLAN ATGROUND FLOOR LEVEL
SH-AR-201JS
1:100
NOTES
ARCHITECTS & PLANNERS
CLIENTS
- Dimensions are not to be scaled.- All Dimensions are in Millimeters unless statedotherwise.- All Levels are in Millimeters and relate to ...........Datum level.- The contractor shall verify all dimensions,details,specifications &site conditions & shall report any error, omissionand/or anomaly tothe architect before commencement of work.- For construction purposes, the dimensions shall notbe measureddirectly of the drawings. The drawings shall not beused forconstruction until they are issued for construction.-These drawings are to be read in co-ordination withhvac,electrical, plumbing drawings & all relevant sections ofspecifications..-All shop drawings should be provided to the architectfor approval.
Job Title
Drawing Title
Architect's Signature
Document Release Type
Revision No.
Drawing No.
Drawn by
Job No.
A U T H O R I T Y :
Scale
Date
Checked by
ARCOP ASSOCIATES PVT. LTD.E-106, G.K. ENCLAVE PART 1NEW DELHI 110048PHONE : 011 - 26242050FAX : 011 - 26242035
Indian Institute of Technology(IIT) Indore,Institute of Engineering and Technology, DAVV Campus,Khandwa Road, Indore 452017Madhya Pradesh, India
1. VENDORS TO PROVIDE SHOP DRAWINGS FOR THE APPROVALFROM THE ARCHITECT.
Client's Signature
ISSUES
REVISIONDATE DESCRIPTION
R0PS
STRUCTURAL CONSULTANT
ELECTRICAL &HVAC CONSULTANTMJ ConsultantsNEW DELHI 110020
MKG ConsultantsNEW DELHI 110020
PLUMBING & FIRE FIGHTING
PMC's Signature
PROJECT MANAGERMECON LIMITEDRANCHI-834002, JHARKHAND, INDIA.TEL :0651-2483440,2481707
IITI INDOOR SPORTS CENTER
NOV 01, 2012
Technical Projects ConsultantsNew Delhi-110025 (India)
2012/18
IIT
IND
OR
E
Key Plan:
INDOOR SPORTS CENTER
IIT
IND
OR
E
SPACE FORWATER TANKS FOR
TOILETS
4800
FFLTOS
+3400+3350
+27
25+
2675
SH-M-01
SH-F-04
SC-02
MEZZANINE FLOOR PLANSCALE-1:200
FHC
1545
TENDER DRAWING
FLOOR PLAN ATMEZZANINE LEVEL
SH-AR-202JS
1:100
NOTES
ARCHITECTS & PLANNERS
CLIENTS
- Dimensions are not to be scaled.- All Dimensions are in Millimeters unless statedotherwise.- All Levels are in Millimeters and relate to ...........Datum level.- The contractor shall verify all dimensions,details,specifications &site conditions & shall report any error, omissionand/or anomaly tothe architect before commencement of work.- For construction purposes, the dimensions shall notbe measureddirectly of the drawings. The drawings shall not beused forconstruction until they are issued for construction.-These drawings are to be read in co-ordination withhvac,electrical, plumbing drawings & all relevant sections ofspecifications..-All shop drawings should be provided to the architectfor approval.
Job Title
Drawing Title
Architect's Signature
Document Release Type
Revision No.
Drawing No.
Drawn by
Job No.
A U T H O R I T Y :
Scale
Date
Checked by
ARCOP ASSOCIATES PVT. LTD.E-106, G.K. ENCLAVE PART 1NEW DELHI 110048PHONE : 011 - 26242050FAX : 011 - 26242035
Indian Institute of Technology(IIT) Indore,Institute of Engineering and Technology, DAVV Campus,Khandwa Road, Indore 452017Madhya Pradesh, India
1. VENDORS TO PROVIDE SHOP DRAWINGS FOR THE APPROVALFROM THE ARCHITECT.
Client's Signature
ISSUES
REVISIONDATE DESCRIPTION
R0PS
STRUCTURAL CONSULTANT
ELECTRICAL &HVAC CONSULTANTMJ ConsultantsNEW DELHI 110020
MKG ConsultantsNEW DELHI 110020
PLUMBING & FIRE FIGHTING
PMC's Signature
PROJECT MANAGERMECON LIMITEDRANCHI-834002, JHARKHAND, INDIA.TEL :0651-2483440,2481707
IITI INDOOR SPORTS CENTER
NOV 01, 2012
Technical Projects ConsultantsNew Delhi-110025 (India)
2012/18
IIT
IND
OR
E
Key Plan:
INDOOR SPORTS CENTER
IIT
IND
OR
E
+27
25+
2675
FFLTOS
+5575+5175
+78
25+
7775
UP
Up UP
Up
01
02
03
04
01
02
03
04
05 05
VIEWING GALLERY
VIEWING GALLERY
BADMINTON / B.BALL COURTS BELOW
VIEWING GALLERY
AIR- WASHERROOM
3.5 x4.6 mt.
Beam above
4890 31004890489048904890 489048904890 48903100
LOBBYLOBBY
VIEWING GALLERY FOR PLAY GROUND
VIEWING GALLERY
1050 high railing
Up
Louvers
01 02 03 04 05 09 1006 07 08 11
LOBBY
Fixed glazing
01
02
03
04
05
D5D5
4890
1mt. high railing
1mt. high railing
Louvers
+33
25+
3275
900
FFLTOS
+4900+4850 49
FFLTOS
+4900+4850
Up
FFLTOS
+2725+2675
FFLTOS
+3325
FFLTOS
+5425+5175
AIR- WASHER ROOM4.5 X 4.8 mt.
DN
DN
2100
AIR- WASHERROOM
4.5 X 4.8 mt.
YY
D4
D4
FFLTOS
+3325+3275
+27
25+
2675
+33
25+
3275
FFLTOS
+3325+3275
+78
25+
7775
SH-F-01
SH-F-01
SH-F-03
SH-F-02
SH-F-03
SH-F-01
SC-03
Dn
22 18
Dn
37
49 59
01 02 03 04 05 09 1006 07 08 11
01 02 03 04 05 09 1006 07 08 11
2100
32
2210
22
+78
25+
7775
+78
25+
7775
DN
Up
L1L1
L3
L2L2
Total no. of Seats =890
L1
5110
6750
6750
6750
7630
W6aW6a
Alu
min
um p
rofil
e sh
eet
As
wal
l pan
el (
As/
Det
ail)
PP
FHC FHC
TENDER DRAWING
FLOOR PLAN ATFIRST FLOOR LEVEL
SH-AR-203JS
1:100
NOTES
ARCHITECTS & PLANNERS
CLIENTS
- Dimensions are not to be scaled.- All Dimensions are in Millimeters unless statedotherwise.- All Levels are in Millimeters and relate to ...........Datum level.- The contractor shall verify all dimensions,details,specifications &site conditions & shall report any error, omissionand/or anomaly tothe architect before commencement of work.- For construction purposes, the dimensions shall notbe measureddirectly of the drawings. The drawings shall not beused forconstruction until they are issued for construction.-These drawings are to be read in co-ordination withhvac,electrical, plumbing drawings & all relevant sections ofspecifications..-All shop drawings should be provided to the architectfor approval.
Job Title
Drawing Title
Architect's Signature
Document Release Type
Revision No.
Drawing No.
Drawn by
Job No.
A U T H O R I T Y :
Scale
Date
Checked by
ARCOP ASSOCIATES PVT. LTD.E-106, G.K. ENCLAVE PART 1NEW DELHI 110048PHONE : 011 - 26242050FAX : 011 - 26242035
Indian Institute of Technology(IIT) Indore,Institute of Engineering and Technology, DAVV Campus,Khandwa Road, Indore 452017Madhya Pradesh, India
1. VENDORS TO PROVIDE SHOP DRAWINGS FOR THE APPROVALFROM THE ARCHITECT.
Client's Signature
ISSUES
REVISIONDATE DESCRIPTION
R0PS
STRUCTURAL CONSULTANT
ELECTRICAL &HVAC CONSULTANTMJ ConsultantsNEW DELHI 110020
MKG ConsultantsNEW DELHI 110020
PLUMBING & FIRE FIGHTING
PMC's Signature
PROJECT MANAGERMECON LIMITEDRANCHI-834002, JHARKHAND, INDIA.TEL :0651-2483440,2481707
IITI INDOOR SPORTS CENTER
NOV 01, 2012
Technical Projects ConsultantsNew Delhi-110025 (India)
2012/18
IIT
IND
OR
E
Key Plan:
INDOOR SPORTS CENTER
IIT
IND
OR
E
4890 31004890489048904890 489048904890 48903100 4890
RIDGE LVL. +13300
EDGE LVL. +11000
EDGE LVL. +11000
XX
Y
TENDER DRAWING
FLOOR PLAN ATTERRACE LEVEL
SH-AR-204JS
1:100
NOTES
ARCHITECTS & PLANNERS
CLIENTS
- Dimensions are not to be scaled.- All Dimensions are in Millimeters unless statedotherwise.- All Levels are in Millimeters and relate to ...........Datum level.- The contractor shall verify all dimensions,details,specifications &site conditions & shall report any error, omissionand/or anomaly tothe architect before commencement of work.- For construction purposes, the dimensions shall notbe measureddirectly of the drawings. The drawings shall not beused forconstruction until they are issued for construction.-These drawings are to be read in co-ordination withhvac,electrical, plumbing drawings & all relevant sections ofspecifications..-All shop drawings should be provided to the architectfor approval.
Job Title
Drawing Title
Architect's Signature
Document Release Type
Revision No.
Drawing No.
Drawn by
Job No.
A U T H O R I T Y :
Scale
Date
Checked by
ARCOP ASSOCIATES PVT. LTD.E-106, G.K. ENCLAVE PART 1NEW DELHI 110048PHONE : 011 - 26242050FAX : 011 - 26242035
Indian Institute of Technology(IIT) Indore,Institute of Engineering and Technology, DAVV Campus,Khandwa Road, Indore 452017Madhya Pradesh, India
1. VENDORS TO PROVIDE SHOP DRAWINGS FOR THE APPROVALFROM THE ARCHITECT.
Client's Signature
ISSUES
REVISIONDATE DESCRIPTION
R0PS
STRUCTURAL CONSULTANT
ELECTRICAL &HVAC CONSULTANTMJ ConsultantsNEW DELHI 110020
MKG ConsultantsNEW DELHI 110020
PLUMBING & FIRE FIGHTING
PMC's Signature
PROJECT MANAGERMECON LIMITEDRANCHI-834002, JHARKHAND, INDIA.TEL :0651-2483440,2481707
IITI INDOOR SPORTS CENTER
NOV 01, 2012
Technical Projects ConsultantsNew Delhi-110025 (India)
2012/18
IIT
IND
OR
E
Key Plan:
INDOOR SPORTS CENTER
IIT
IND
OR
E