Jaguar VXG 10 - IMO Websitetechnical.imopc.com/vxg_datasheet.pdf · Reset alarm Run forward command...

3
Jaguar VXG Series High Performance Dual Rated AC Variable Speed Drives 3Ø, 400V/50~60Hz, 0.4~630kW (CT) 3Ø, 400V/50~60Hz, 0.4~710kW (VT) User configurable quick-start menu IP20 side-by-side mounting (IP40) Intergrated EMC filter (EN61800-3 2004 cat C3) PLC logic type function RoHS, CE, UL,cUL compliant V/F, Torque Vector and closed loop control 200% starting torque between 0.3Hz Improved open-loop low-speed stability Enable input safety switch Mechanical brake control output - torque generated PID with Dancer control PTC thermistor input Input and Output phase-loss protection Loss-of-command signal detection Thermostatically operated long-life cooling fans (designed to operate for 10 years at 40 o C) Life time / service due alarm output Standard Keypad with mini USB port. Optional multi-function back-lit keypad with parameter COPY mode Encoder feedback (close-loop) and shaft-synchronizing options Synchronous (Permanent Magnet) motor options JAGVXG/04/10 www.imopc.com Y E A R G U A R A N T E E Internal brake chopper up to 22kW (30-110kW upon request)

Transcript of Jaguar VXG 10 - IMO Websitetechnical.imopc.com/vxg_datasheet.pdf · Reset alarm Run forward command...

Page 1: Jaguar VXG 10 - IMO Websitetechnical.imopc.com/vxg_datasheet.pdf · Reset alarm Run forward command Run reverse command Inverter running PTC/NTC - Power switching connector - Fan

Jaguar VXG SeriesHigh Performance Dual Rated AC Variable Speed Drives

3Ø, 400V/50~60Hz, 0.4~630kW (CT)3Ø, 400V/50~60Hz, 0.4~710kW (VT)

User configurable quick-start menu

IP20 side-by-side mounting (IP40)

Intergrated EMC filter (EN61800-3 2004 cat C3)

PLC logic type function

RoHS, CE, UL,cUL compliant

V/F, Torque Vector and closed loop control

200% starting torque between 0.3Hz

Improved open-loop low-speed stability

Enable input safety switch

Mechanical brake control output - torque generated

PID with Dancer control

PTC thermistor input

Input and Output phase-loss protection

Loss-of-command signal detection

Thermostatically operated long-life cooling fans (designed to operate for 10 years at 40oC)

Life time / service due alarm output

Standard Keypad with mini USB port. Optional multi-function back-lit keypad with parameter

COPY mode

Encoder feedback (close-loop) and shaft-synchronizing options

Synchronous (Permanent Magnet) motor options

JAGVXG/04/10 www.imopc.com

YE A R

G U A R A NTEE

Internal brake chopper up to 22kW (30-110kW upon request)

Page 2: Jaguar VXG 10 - IMO Websitetechnical.imopc.com/vxg_datasheet.pdf · Reset alarm Run forward command Run reverse command Inverter running PTC/NTC - Power switching connector - Fan

Jaguar VXG Series continued

JAGVXG/04/10 www.imopc.com

Power and Control Connections

VXG 60AL 4 E

Integrated EMC filter

2 Input voltage 200v/3ph*

4 Input voltage 400v/3ph

CT Rating VT Rating

0.4kW -

0.75kW -

1.5kW -

2.2kW -

4.0kW -

5.5kW 7.5kW

7.5kW 11kW

11kW 15kW

15kW 18.5kW

18.5kW 22kW

22kW 30kW

30kW 37kW

37kW 45kW

45kW 55kW

55kW 75kW

75kW 90kW

90kW 110kW

110kW 132kW

132kW 160kW

160kW 200kW

200kW 220kW

220kW 280kW

280kW 315kW

315kW 355kW

355kW 400kW

400kW 500kW

500kW 630kW

630kW 710kW

-

Options and ordering codes

1A5

2A54A

5.5A9A

16A5L23AL30A5L37AL45AL

E

A60AL

75AL

91AL

112AL

150AL

176AL210AL253AL304AL377AL415AL

A520AL

650AL

740AL

840AL

960AL

1170AL

1370AL

*Special order only

USB connector

Digital input

[ ]MCCB orRCD/ELCB

400 V class series380 to 480 V

50/60 Hz

Power supply

MC FUSE

DCR

P1

P(+)

DBR

MotorL1/R

P1U

V

W

Grounding terminal

*9

*9

*9

*12

Analog frequencymeter

30A30B30C

30

P DB

CMTHR

12

13

11

FM2

C1 Y4Y3

CMY

FWDREV

X1X2X3X4X5

CM

Alarm output(for any alarm)

L2/S

L3/T

GGGrounding terminal

Analog inputPotentiometer power supply

Voltage input forfrequency setting

0 to +10 VDC(0 to ±10 VDC)

Current input forfrequency setting4 to 20 mA DC

1

2

3

(+)(-)

Auxiliary control power input

Auxiliary fan power input

X6X7

11

Y2Y1

V2Voltage input forfrequency setting

0 to ±10 VDC(+)(-)

+10 VDC 0 V

+24 VDC 0 V

SW6

SW5

AX terminalfunction

Motor overload early warningTransistor outputs

Contact outputs

Frequency/speed detectedFrequency/speed arrival

Common terminalPLCEN1

EN2

Y5CY5A

+

R0T0

R1T1

SINK

SOURCE

SW1

SW2

DX-

SD

Data transmission

RS-485 COM port 1(RJ-45 connector for keypad)

Main circuit

Control circuit

DX+

*8

*3

*2*13

*6

*5

*4

*11

*11

*11

*11

*11

*10

*7

DB N(-)P(+)

RS-485 COM port 2 (TB)

Analog frequencymeter

FM1

11SW4

4 to 20mA DC

*11

*1

PLC

0 to 10VDC

4 to 20mA DC

0 to 10VDC

DBR :DCR :RCD :

ELCB :MC :MCCB :

Dynamic Braking ResistorDC ReactorResidual-current-operatedprotective deviceEarth Leakage Circuit BreakerMagnetic ContactorMolded Case Circuit Breaker

Safety relay module

complying with more than

EN954-1/EN ISO13849-1

Cat.3

Select multi-frequency (0 to 1 step)Select multi-frequency (0 to 3 step)Select multi-frequency (0 to 7 step)

Select multi-frequency (0 to 15 step)Select ACC/DEC time (2 steps)Select ACC/DEC time (4 steps)

Reset alarm

Run forward commandRun reverse command

Inverter running

PTC/NTC

- Power switching connector

- Fan power supply switching connector(CN UX)

)/(CN W)(CN R *10

SW3

DBR

M3

C

M

Y

CM

MY

CY

CMY

K

Jaguar_VXG_data sheet.pdf 10/11/2011 12:38:51 PM

Page 3: Jaguar VXG 10 - IMO Websitetechnical.imopc.com/vxg_datasheet.pdf · Reset alarm Run forward command Run reverse command Inverter running PTC/NTC - Power switching connector - Fan

Jaguar VXG Series continued

JAGVXG/04/10

Specifications and Dimensions

www.imopc.com

VXG5.5A-4E 2.2 - VXG9A-4E 4 -

VXG23AL-4E 7.5 11 VXG30A5L-4E 11 15

VXG45AL-4E 18.5 22 VXG60AL-4E 22 30

VXG91AL-4E 37 45

VXG253AL-4E 110 132

VXG377AL-4E 160 200

VXG520AL-4E 220 280

VXG650AL-4E 280 315 VXG740AL-4E 315 355 VXG840AL-4E 355 400 VXG960AL-4E 400 500 VXG1170AL-4E 500 630 VXG1370AL-4E 630 710

5.5

0.40.75

110

260

200

7590

4555

15

30326.2

361.2

535.8

150

1000

220

250

261.3

276.3

130

145

195

400

Power supply voltage

1000

Thre

e Ph

ase

400

V

321.3

366.3

550

686.4

615675

740 VXG210AL-4E

VXG304AL-4E

VXG415AL-4E

1400

1550

440

500

536.4

880

132

Depth

VXG2A5-4E VXG4A-4E

Inverter typeMain body external dimensions (mm)Motor

Rating (CT) Width Height

1.5

VXG1A5-4E

VXG16A5L-4E

VXG37AL-4E

VXG75AL-4E

VXG112AL-4E

VXG176AL-4E VXG150AL-4E

-

Motor Rating (VT)

--

7.5

18.5

220

37

557590110

160