IZOLATORI MT Re Comp Last Catalog-Web

download IZOLATORI MT Re Comp Last Catalog-Web

of 48

Transcript of IZOLATORI MT Re Comp Last Catalog-Web

CUPRINS / CONTENTS

Pagina Page

1

LEA JTBLOCURI SI FIRIDE / MEASUREMENT AND PROTECTION UNITBLOCURI DE MASUR I PROTECIE MONOFAZATE MONOPHASE MEASUREMENT AND PROTECTION UNIT BLOCURI CU MASURA SI PROTECTIE TRIFAZATE THREE-PHASE MEASUREMENT AND PROTECTION UNITS FIRIDE DE DISTRIBITIE SI CONTORIZARE PALIER FIRIDE DE DISTRIBUTIE SI CONTORIZARE CU PRINDERE PE STALPMULTI BOXESFOR PROTECTION AND MEASUREMENT OF POWER DISTRIBUTION BMPM BMPT FDCP FDCS 1 4 11

CLEME SI ACCESORII PENTRU BRANSAMENTE / CLAMPS AND ACCESSORIES FOR BRANCHINGSCap 1 Cap 2 2.1. 2.2. Cap 3 Cap 4 CLEME DE DERIVATIE CU DINTI : CDD45, CDDM, CDDCN, CDDLP, CDDIL INSULATION PIERCING CONNECTORS CLEME DE INTINDERE / DEAD-END CLAMPS CLEME DE INTINDERE BRANSAMENT : CIB, CIBMU, CIBT DEAD-END CLAMPS FOR BRANCHING CLEME DE INTINDERE RETEA : CIR DEAD-END TENSION CLAMP SBCB, CS, SBCB-01, SBCB-02, IBIZ, GET ACCESORII DE BRANSAMENT: BRANCHING ACCESSORIES ACCESORII PENTRU LEA JT : ACCESSORIES FOR LOW VOLTAGE OVERHEAD LINES AUB, BBS, CSB, CS, AU, IR, P, TF, TI, TS, ASC , ASA, CLE, CA, CB 14 16 18 18 19

2

LEA MTIZOLATOR COMPOZIT DE INTINDERE TIP TIJA RICIS SUSPENSION COMPOSITE INSULATOR LANTURI CU IZOLATOARE COMPOZITE LSS, LDS,LSV,LST,LDT STRINGS WITH COMPOSITE INSULATORS IZOLATORI COMPOZITI SUPORTRICS-CBA, RICS-CS, RICS-CC, RICS-A COMPOSITE LINE POST INSULATORS ARMATURI PENTRU LANTURI DE IZOLATOARE : HARDWARE FOR MEDIUM VOLTAGE INSULATOR STRINGS Carlige B1, U60, Armatura tip A, Juguri, Cleme CTPF, CSLAC, Piese PR, PDD 1 2 3 11

3

Aparataj JTINTRERUPTOARE AUTOMATE : INTRERUPTOARE AUTOMATE CU PROTECTIE DIFERENTIALA: NTRERUPTOARE DIFERENTIALE : NTRERUPTOARE DIFERENTIALE FARA PROTECTIE LA SUPRACURENT: BOBINE DE DECLANSARE : CARACTERISTICI TEHNICE RB1(H)-63 RB1L(H) RB47LE RL1-63 RS-9 1 2 3 4 5 6

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES RICIS IZOLATOR COMPOZIT DE INTINDERE TIP TIJA PENTRU LEA 20 kV SUSPENSION COMPOSITE INSULATORSIMBOLIZARE : RICIS-20-IV-70-CT-150 RICIS : Recomplast Izolator Compozit Intindere si Sustinere Recomplast suspension composite insulator 20 IV 70 CT 150 : tensiunea nominala de linie (kVef) nominal system voltage : zona de poluare conform CEI 815/1993 polution level : sarcina mecanica specifica [KN] Specified mechanical load (SML) : tipul asamblarii de capat Nr crt End fittings : tensiunea de tinere la impuls de 1 trasnet (STA);2 3

CARACTERISTICA / TEHNICAL DATA Tensiunea nominala a retelei Rated system voltage Tensiunea maxima a retelei Maximum system voltage Frecventa nominala Rated frequency Tensiunea de tinere 50 Hz 1 minut sub ploaie Wet power frequency withstand Tensiunea de tinere 50% conturnari la impuls 1,2/50 s in stare uscata.(val de virf) 50 % dry lighting impulse flashover voltage Tensiunea de tinere la impuls de traznet 1,2/50 s in stare uscata (val.de virf) Dry lighting impulse withstand nominal voltage, wave 1,2/50 s peak value Zona de poluare Polution level Lungimea liniei de fuga Creepage distance Numar de rile Number of sheds Lungime izolator intre punctele de prindere Lenght (between fixing points) Sarcina mecanica specificata (SMS) Specified mechanical load (SML) Sarcina mecanica individuala (SMI)** Routine test load (RTL) Masa izolator Weight Ambalare cutii de carton Packing in carton boxes Durata de viata normata Rated life time

U.M. M.U. kVef kVef Hz

VALOARE VALUE 20 24 50

NORMATIVE DE REFERINTA: CEI 1109, ST 5/1999-Electrica SA MOD DE COMANDARE : RICIS - IV - 70

4

kVef

50

5

Kv max

160

6

Kv max

150

7 8 9 10 11 12 13 14 Poz Item 1 2 3 Denumire reper / Description Tija Rile Capete terminale Cant Quantity (buc/pcs) 1 4/5/6 2 15

I - II mm 480 4

III 658 5

IV 750 6

mm kN kN kgBuc/cutie Pcs/box

333

384 70 35**

435

1.12 1.22 1 30

1.33

ani years

(**) se poate efectua, pe baza unei nelegeri ntre productor i client, ncercarea la 70% SMS

LEA MT

1 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES LSS LANT SIMPLU DE SUSTINERE CU IZOLATOR COMPOZIT PENTRU LEA 20 kV SINGLE SUSPENSION STRING WITH COMPOSITE INSULATORSIMBOLIZARE :

LSS-RICIS-20-II-70: Lant Simplu de Sustinere Single suspension string RICIS : Tip izolator Insulator type 20 : Tensiunea nominala de linie (kVef) Nominal system voltage II : Zona de poluare Polution level 70 : sarcina mecanica specifica [KN] Specified mechanical load (SML) LSS

NORMATIVE DE REFERINTA: CEI 1109, ST 5/1999-Electrica SA MOD DE COMANDARE :

LSS - II - 70- FE (L) - CSLAC 50-70unde FE (L) : Faza extrema (laterala) Extreme phase placed CSLAC : Clema de Sustinere Linie cu Alunecare Controlata Controlled slippage line suspension clamp 50-70 : Sectiunea conductorului de retea (mm) Conductor size

Poz Item

Denumire reper / Description

Cant Quantity (buc/pcs)

Masa / Weight (kg / buc )

Zona de poluare / Polution level1 2 3 Carlig U60, M12 / U60 bolt Carlig de sustinere B 1 / B1 bolt Izolator RICIS / RICIS Insulator Clema CSLAC 50-70/ CSLAC clamp 1 1 1 1

Faza extrema (FE ) / Extreme phase I - II III IV0.35

Faza mijloc (FM ) / Middle phase I - II III IV 0.76

1.12 1.22 0.45 1.33 1.12

1.22 0.45

1.33

Lungime lant / Length string (mm)Masa lant / Weight string

5081.92

5592.02

6102.13

4732.33

5242.43

5752.54

LEA MT

2 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES LDS LANT DUBLU DE SUSTINERE CU IZOLATOR COMPOZIT PENTRU LEA 20 kV DOUBLE SUSPENSION STRING WITH COMPOSITE INSULATORSIMBOLIZARE :

LDS- RICIS-20-II-70: Lant Dublu de Sustinere Double suspension string RICIS : Tip izolator Insulator type 20 : Tensiunea nominala de linie (kVef) Nominal system voltage II : Zona de poluare Polution level 70 : sarcina mecanica specifica [KN] Specified mechanical load (SML) LDS

NORMATIVE DE REFERINTA: CEI 1109, ST 5/1999-Electrica SA MOD DE COMANDARE :

LDS- II - 70- FE (L) - CSLAC 50-70unde FE (L) : Faza extrema (laterala) Extreme phase placed CSLAC : Clema de Sustinere Linie cu Alunecare Controlata Controlled slippage line suspension clamp 50-70 : Sectiunea conductorului de retea (mm ) Conductor sizeMasa / Weight (kg / buc )

Poz Item

Denumire reper / Description

Cantitate Quantity (buc/pcs)

Zona de poluare / Polution level 1 2 3 4 5 Carlig de sustinere U60 M12 / U60 bolt, M12 Carlig de sustinere B 1 / B1 bolt Piesa rasucita PR 75 / Twistwd piece Jug simplu JS 140 / Single yoke Izolator RICIS / RICIS Insulator Clema CSLAC 50-70/ CSLAC clamp Lungime lant / Length string (mm) Masa lant / Weight string 1 1 2 2 2 1

Faza extrema (FE ) / Extreme phase II III IV 0..35 0.24 1.08 1.12 718 5.68 1.22 0.45 769 5.88 820 6.1 1.33

Faza mijloc (FM ) / Middle phase II III IV 0.76 0.24 1.08 1.12 683 6.09 1.22 0.45 734 6.29 785 6.51 1.33

LEA MT

3 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES LSV LANT DE SUSTINERE IN V CU IZOLATOR COMPOZIT PENTRU LEA 20 kV V SUSPENSION STRING WITH COMPOSITE INSULATORSIMBOLIZARE :

LSV- RICIS-20-II-70: Lant de Sustinere in V V suspension string RICIS : Tip izolator Insulator type 20 : Tensiunea nominala de linie (kVef) Nominal system voltage II : Zona de poluare Polution level 70 : sarcina mecanica specifica [KN] Specified mechanical load (SML) LSV

NORMATIVE DE REFERINTA: CEI 1109, ST 5/1999-Electrica SA

MOD DE COMANDARE :

LSV- II - 70- FE (L) - CSLAC 50-70unde FE (L) : Faza extrema (laterala) Extreme phase placed CSLAC : Clema de Sustinere Linie cu Alunecare Controlata Controlled slippage line suspension clamp 50-70 : Sectiunea conductorului de retea (mm ) Conductor size

Poz Item

Denumire reper / Description Zona de poluare / Polution level

Cantitate Quantity (buc/pcs) II 2 2 2 1 1 1 578 5.55 1.12

Masa Weight (kg / buc ) III 0.35 0.42 1.22 0.24 1.08 0.45 629 5.75 680 5.97 1.33 IV

1 2 3 4 5 6

Carlig de sustinere U60 M12 / U60 bolt, M12 Piesa dubla de distantare PDD 55 / Double extension piece Izolator RICIS / RICIS Insulator Piesa rasucita PR 75 / Twistwd piece Jug simplu JS 140 / Single yoke Clema CSLAC/ CSLAC clamp Lungime lant / Length string (mm) Masa lant / Weight string

LEA MT

4 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES LST LANT SIMPLU DE TRACTIUNE CU IZOLATOR COMPOZIT PENTRU LEA 20 kV SINGLE TENSION STRING WITH COMPOSITE INSULATORSIMBOLIZARE :

LST- RICIS-20-II-70LST : Lant Simplu de Tractiune Single tension string RICIS : Tip izolator Insulator type 20 : Tensiunea nominala de linie (kVef) Nominal system voltage II : Zona de poluare Polution level 70 : sarcina mecanica specifica- SMS [KN] Specified mechanical load (SML)

NORMATIVE DE REFERINTA: CEI 1109, ST 5/1999-Electrica SA MOD DE COMANDARE :

LST - II - 70- FE (L) - CPTF sau LST - II - 70- FE (L) - CLAMI 35-50unde FE (L) : Faza extrema (laterala) Extreme phase placed CTPF : Clema Tractiune Potcovita Tension clamp CLAMI : Clema Amagnetica de intindere Bolted strained tension clamp 35-50 : Sectiunea conductorului de retea (mm) Conductor size

Poz Item

Denumire reper / Description Zona de poluare / Polution level

Cant Quantity (buc/pcs)

Masa / Weight (kg / buc )

Faza extrema (FE ) / Extreme phase I - II III IV0.35

Faza mijloc (FM ) / Middle phase I - II III IV 0.76

1 2 3

Carlig U60, M12 / U60 bolt Carlig de sustinere B 1 / B1 bolt Izolator RICIS / RICIS Insulator Clema CTPF/ CTPF clamp Clema CLAMI 35-50 / CLAMI clamp

1 1 1 1 1.12

1.22 0.45 0.58 1.33 1.12

1.22 0.45 0.58

1.33

Lungime lant / Length string (mm)Masa lant cu CTPF / Weight string

5081.92

5592.02

6102.13

4732.33

5242.43

5752.54

LEA MT

5 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES

LDT

LANT DUBLU DE TRACTIUNE CU IZOLATOR COMPOZIT PENTRU LEA 20 kV DOUBLE TENSION STRING WITH COMPOSITE INSULATORSIMBOLIZARE :

LDT- RICIS-20-II-70LDT : Lant Dublu de Tractiune Double tension string RICIS : Tip izolator Insulator type 20 : Tensiunea nominala de linie (kVef) Nominal system voltage II : Zona de poluare Polution level 70 : sarcina mecanica specifica [KN] Specified mechanical load (SML)

NORMATIVE DE REFERINTA: CEI 1109, ST 5/1999-Electrica SA MOD DE COMANDARE :

LDT - II - 70- FE (L) - CPTF sau LDT - II - 70- FE (L) - CLAMI 35-50unde FE (L) : Faza extrema (laterala) Extreme phase placed CTPF : Clema Tractiune Potcivita Tension clamp CLAMI : Clema Amagnetica de intindere Bolted strained tension clamp 35-50 : Sectiunea conductorului de retea (mm )Cantitate Quantity (buc/pcs) Masa / Weight (kg / buc )

Poz Item

Denumire reper / Description

Zona de poluare / Polution level 1 2 3 4 5 Carlig de sustinere U60 M12 / U60 bolt, M12 Carlig de sustinere B 1 / B1 bolt Piesa rasucita PR 75 / Twistwd piece Jug simplu JS 140 / Single yoke Izolator RICIS / RICIS Insulator Clema CTPF/ CTPF clamp Clema CLAMI 35-50 / CLAMI clamp Lungime lant / Length string (mm) Masa lant cu CTPF / Weight string 1 1 2 2 2 1

Faza extrema (FE ) / Extreme phase II III IV 0..35 0.24 1.08 1.12 1.22 0.45 0.58 708 5.68 759 5.88 810 6.1 1.33

Faza mijloc (FM ) / Middle phase II III IV 0.76 0.24 1.08 1.12 1.22 0.45 0.58 673 6.09 724 6.29 775 6.51 1.33

LEA MT

6 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINESRICS-CBA IZOLATOR COMPOZIT SUPORT CU CLEMA BASCULANTA CU ALUNECARE CONTROLATA A CONDUCTORULUI, CU ARC COMPOSITE LINE POST INSULATOR WITH ROCKING ARC CLAMPMOD DE COMANDARE : RICS-20-II-10- CBA-35 /120 unde 35 : Sectiunea conductorului de retea (mm ) Conductor size 120 : lungimea boltului de prindere la consola mounting bolts length

SIMBOLIZARE : RICS-20-II-10- CBA

RICS : Recomplast Izolator Compozit Suport Recomplast composite line post insulator 20 : Tensiunea nominala de linie (kVef) Nominal system voltage II : Zona de poluare Polution level 10 : sarcina mecanica specifica de rupere la incovoiere- SCL [KN] Specified cantilevel load (SCL) CBA : Clema Basculanta cu Arc, cu retinerea controlata a conductorului Rocking arc clampNr crt 1 2 3

NORMATIVE DE REFERINTA: CEI 61952, ST 5/1999-Electrica SA

CARACTERISTICA /TEHNICAL DATA Tensiunea nominala a retelei Rated system voltage Tensiunea maxima a retelei Maximum system voltage Frecventa nominala Rated frequency Tensiunea de tinere, 50 Hz, 1 min,uscat , sub ploaie Wet power frequency withstand Tensiunea de tinere la impuls de traznet 1,2/50 s in stare uscata Dry lighting impulse withstand voltage Tensiunea de tinere 50% conturnari la impuls 1,2/50 s in stare uscata.(val de virf) 50 % dry lighting impulse flashover voltage Zona de poluare Polution level Lungimea liniei de fuga Creepage distance Numar de rile Number of sheds Sarcina mecanica specifica la incovoiere (SLC) Specified cantilever load (SCL) Lungime izolator ( L ) Insulator length Lungimea prezonului de prindere pe consola (L) Mounting bolts length Gama de sectiuni conductor Ol-Al Section range of the steel-aluminium conductors Masa izolator Weight Masa prezon Weight Ambalare cutii de carton Packing in carton boxes Durata de viata normata Rated life time

U.M. M.U. kVef kVef Hz

VALOARE VALUE 20 24 50

4

kVef

50

5

Kv max

125

6

Kv max

125-160

7 8 9 10 11 12 Cantitate Quantity (buc/pcs) 1 1 1 1 1 1 17 16 15 13 14

II mm 480 3 kN mm mm mm kg kg Buc/cutie Pcs/box ani years 2.65 298

III 658 4 10 329

IV 750 5

360

120 / 210* 35 120 2.83 3.03

Poz Item 1 2 3 4 5 6

Denumire reper / Description Izolator / Insulator Prezon M20/ M20 mounting bolt Saiba plata A20 / A20 washer Saiba grower N20 / N20 Spring washer Piulita M20/ M20 nut Clema basculanta / Rocking arc clamp

0.43 / 0.62 1 30

*la cerere putem executa orice dimensiune de prezon dorita

LEA MT

7 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES RICS-CS IZOLATOR COMPOZIT SUPORT CU CAP SFERIC COMPOSITE LINE POST INSULATOR WITH ROUNDED HEAD

SIMBOLIZARE : RICS-CS -24-II RICS : Recomplast Izolator Compozit Suport Recomplast composite line post insulator CS : cu cap sferic with rounded head 24 : tensiunea maxima de linie( kVef) maximum system voltage II : zona de poluare conform CEI 815/1993 polution level

MOD DE COMANDARE :

RICS-CS-II /120unde 120 : lungimea boltului de prindere la consola / mounting bolts length

NORMATIVE DE REFERINTA: CEI 61952, ST 5/1999-Electrica SA

Nr crt 1

CARACTERISTICA / TEHNICAL DATA Tensiunea nominala a retelei Rated system voltage Tensiunea maxima a retelei Maximum system voltage Frecventa nominala Rated frequency Tensiunea de tinere, 50 Hz, 1 min,uscat , sub ploaie Wet power frequency withstand Tensiunea de tinere la impuls de traznet 1,2/50 s in stare uscata dry lighting impulse withstand voltage Tensiunea de tinere 50% conturnari la impuls 1,2/50 s in stare uscata.(val de virf) 50 % dry lighting impulse flashover voltage Zona de poluare Polution level Lungimea liniei de fuga Creepage distance Numar de rile Number of sheds Sarcina mecanica specifica la incovoiere (SLC) Specified cantilever load (SCL) Lungime izolator ( L ) Insulator length Lungimea prezonului de prindere pe consola (L) Mounting bolts length Gama de sectiuni conductor Ol-Al Section range of the steel-aluminium conductors Masa izolator Weight Masa prezon Weight Ambalare cutii de carton Packing in carton boxes Durata de viata normata Rated life time

U.M. M.U. kVef kVef Hz

VALOARE VALUE 20 24 50

75 52

R 9,5

18

2 3

4

kVef

50

1 L

5

Kv max

125

6 168

Kv max

125-160

7 8 9

II mm 480 3 kN mm mm mm kg kg Buc/cutie Pcs/box ani years 2.53 306

III 658 4 10 337

IV 750 5

2 3 l 4 5M20

10 11 12 13 14 15 16 17

368

120 / 210* 35 120 2.67 2.82

Poz Item 1 2 3 4 5

Denumire reper / Description Izolator / Insulator Prezon M20/ M20 mounting bolt Saiba plata A20 / A20 washer Saiba grower N20 / N20 Spring washer Piulita M20/ M20 nut

Cantitate Quantity (buc/pcs) 1 1 1 1 1

0.43 / 0.62 1 30

*la cerere putem executa orice dimensiune de prezon dorita

LEA MT

8 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES RICS-CC IZOLATOR COMPOZIT SUPORT CU CLEMA C PENTRU LEA 20 kV COMPOSITE LINE POST INSULATOR WITH CCLAMP

SIMBOLIZARE : RICS-CC -24-II RICS : Recomplast Izolator Compozit Suport Recomplast composite line post insulator CC : cu clema tip C with C clamp 24 : tensiunea maxima de linie( kVef) Nr maximum system voltage crt II : zona de poluare conform CEI 815/1993 1 polution level 120 : lungimea boltului de prindere la 2 consola mounting bolts length3 MOD DE COMANDARE : RICS-CC-II /120 120 : lungimea boltului de prindere la consola mounting bolts length U.M. M.U. kVef kVef Hz kVef VALOARE VALUE 20 24 50 50

CARACTERISTICA / TEHNICAL DATA Tensiunea nominala a retelei Rated system voltage Tensiunea maxima a retelei Maximum system voltage Frecventa nominala Rated frequency Tensiunea de tinere, 50 Hz, 1 min,uscat, sub ploaie / Wet power frequency withstand Tensiunea de tinere la impuls de traznet 1,2/50 s in stare uscata dry lighting impulse withstand voltage Tensiunea de tinere 50% conturnari la impuls 1,2/50 s in stare uscata.(val de virf) 50 % dry lighting impulse flashover voltage Zona de poluare Polution level Lungimea liniei de fuga Creepage distance Numar de rile Number of sheds Sarcina de tractiune specificata (STL) Specified tensile load Sarcina maxima de incovoiere in exploatare (MDCL) / Maximum design cantilever load Sarcina mecanica specifica la incovoiere (SLC) / Specified cantilever load (SCL) Lungime izolator ( L ) Insulator length Lungimea prezonului de prindere pe consola (l) / Mounting bolts length

NORMATIVE DE REFERINTA: CEI 61952, ST 5/1999-Electrica SA

4

5

Kv max

125

63 2

Kv max

125-160

7 8

II mm 480 3 kN kN kN mm mm 290

III 658 4 20 6 10 321

IV 750 5

168

L

9 10 11

1 4 6 7 5M20

12 13l

352

14Denumire reper / Component Capa fixare Tija / Insulator Clema C / C Clamp Prezon / Mounting bolt Piulita hexagonala M20 Hexagon nut Saiba plata A20 / Plain washer Saiba Grower N20 / Spring washer Buc. / Pcs. 1 1 1 1 1 1 1

120 / 240*

Poz. 1 2 3 4 5 6 7

Gama de sectiuni conductor Ol-Al 15 Section range of the steel-aluminium conductors 16 17 18 19 Masa izolator Weight Masa prezon Weight Ambalare cutii de carton Packing in carton boxes Durata de viata normata Rated life time

mm

35 120

kg kgBuc/cutie

2.53 2.67 2.82 0.43 / 0.62 1 30

Pcs/box

ani years

*la cerere putem executa orice dimensiune de prezon dorita.

LEA MT

9 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES RICS-A IZOLATOR COMPOZIT SUPORT PENTRU APARATAJ ELECTRIC COMPOSITE STATION POST INSULATORMOD DE COMANDARE : RICS-20-II-10- A / 120 unde 10 : Sarcina mecanica specificata (SLC) 120 : lungimea boltului de prindere la consola mounting bolts length U.M. M.U. kVef kVef Hz kVef VALOARE VALUE 20 24 50 50

SIMBOLIZARE : RICS-A -24-II

RICS : Recomplast Izolator Compozit Suport Recomplast composite station post insulator A : pentru aparataj electric Nr for electrical equipment CARACTERISTICA / TEHNICAL DATA crt 24 : tensiunea maxima de linie( kVef) maximum system voltage Tensiunea nominala a retelei 1 II : zona de poluare conform CEI Rated system voltage 815/1993 Tensiunea maxima a retelei polution level 2Maximum system voltage

NORMATIVE DE REFERINTA: CEI 61952, ST 5/1999-Electrica SA

3 4

Frecventa nominala Rated frequency Tensiunea de tinere, 50 Hz, 1 min,uscat , sub ploaie / Wet power frequency withstand Tensiunea de tinere la impuls de traznet 1,2/50 s in stare uscata Dry lighting impulse withstand voltage Tensiunea de tinere 50% conturnari la impuls 1,2/50 s in stare uscata.(val de virf) 50 % dry lighting impulse flashover voltage Zona de poluare Polution level Lungimea liniei de fuga Creepage distance Numar de rile Number of sheds Sarcina de tractiune specificata (STL) Specified tensile load Sarcina maxima de incovoiere in exploatare (MDCL) / Maximum design cantilever load

5

Kv max

125

3 26

Kv max

125-160

7 168

II mm 480 3 kN kN

III 658 4 20 6

IV 750 5

8L

9 10 11

1 4 6 7 5M20

Sarcina mecanica specifica la incovoiere 12 (SLC) Specified cantilever load (SCL) 13 Lungime izolator ( L ) Insulator lengthl

kN

10

mm

276

307

338

Lungimea prezonului de prindere pe consola 14 (l) Mounting bolts length Gama de sectiuni conductor Ol-Al 15 Section range of the steel-aluminium conductors 16 17 18 19 Masa izolator Weight Masa prezon Weight Ambalare cutii de carton Packing in carton boxes Durata de viata normata Rated life time

mm

120 / 240*

Poz. 1 2 3 4 5 6 7

Denumire reper / Component Capa fixare Tija / Insulator Capa aparataj Prezon / Mounting bolt Piulita hexagonala M20 Hexagon nut Saiba plata A20 / Plain washer Saiba Grower N20 / Spring washer

Buc. / Pcs. 1 1 1 1 1 1 1

mm

35 120

kg kg Buc/cutie Pcs/box ani years

2.53 2.67 2.82 0.43 / 0.62 1 30

*la cerere putem executa orice dimensiune de prezon dorita.

LEA MT

10 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES ARMATURI PENTRU LANTURI DE IZOLATOARE HARDWARE FOR MEDIUM VOLTAGE INSULATOR STRINGS

Carlig B1 / B1 bolt :UTILIZARE : lanturi de izolatoare MT, faza de mijloc FIELD OF APPLICATION: strings with composite insulators for medium voltage, middle phaseCantitate (buc) Quantity (pcs) 1 1 1 1 2 1 1

Poz 1 2 3 4 5 6 7

Denumire reper / Component Surub cap hexagonal M16x20 / Hexagon cap screw Brida / Arm clip Saiba plata A 16 / Plain washer Piulita hexagonala M16 / Hexagon nut Splint 4 x 30 / Splint Bolt / Bolt Saiba plata A 12 / Plain washer

Denumire produs Label B1

Efort nominal orizontal / Orizontal rated strength (kN) 70

Greutate Weight (kg) 0,76

Ambalare (buc/cutie) Packing (pcs/box) 50

Carlig U60 / U60 bolt :UTILIZARE : lanturi de izolatoare MT, faza extrema (laterala) FIELD OF USE: strings with composite insulators for medium voltage, extreme phaseL3

M 12

1 2

Poz Denumire reper / Component 1 2 Corp carlig / Bolt body Piulita hexagonala M12 / M 16 / Hexagon nut

Cantitate (buc)/ Quantity (pcs) 1 6

B2

A1

0 R3

Loc pt. marcare

Denumire produs Label U 60 /M 12 U 60 /M 16

Efort nominal orizontal Orizontal rated strength (kN) 70 70

Greutate Weight (kg) 0,35 0.60

Ambalare (buc/cutie) Packing (pcs/box) 50 50

Simbol carlig

U1 U2

Dimensiuni /Dimensions (mm) A B L L desf 115 116 152 326 195 196 232 486

LEA MT

11 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES ARMATURI PENTRU LANTURI DE IZOLATOARE HARDWARE FOR MEDIUM VOLTAGE INSULATOR STRINGS Armatura tip AUTILIZARE : lanturi de izolatoare MT, faza extrema (laterala) FIELD OF USE: strings with composite insulators for medium voltage, extreme phase Poz Denumire reper Component Corp carlig / Bolt body Piulita hexagonala M12 / M16 Hexagon nut Cantitate (buc) Quantity (pcs) 1 6601 M 12 (M 16)

1 2

B2

A1

Simbol carlig A 2-60 A 4-80 A 6-120

Dimensiuni / Dimensions (mm) A B C L L desf 115 116 60 152 326 135 175 136 176 80 120 172 212 366 446

L3

1 2

R3

0

Loc pt. marcare

Jug simplu JS 140/8 / Single yokeUTILIZARE : lanturi duble cu izolatoare MT FIELD OF USE: double strings with composite insulators for medium voltage70 180 = =

Poz 1 2 3 4

Denumire reper Component Bolt / Bolt Splint 4x30 / Splint Saiba A 16 / Washer Corp jug / Yoke body

Cantitate (buc) Quantity (pcs) 3 3 3 2

C1

1 2 3Min 16 140

Denumire produs / Label JS 140 / 8

Efort nominal Rated strength (kN) 70

Greutate Weight (kg) 1.117

4

Clema de tractiune potcovita CTPF 120 / CTPF clampUTILIZARE : lanturi de intindere (tractiune) cu izolatoare MT FIELD OF USE: tension strings with composite insulators for medium voltage Poz 1 2 3 4 5 Denumire reper Label Bolt / Bolt Saiba A 12 / / Washer Jug sustinere / Suspension yoke Splint 4x30 / Splint Potcovita / Horseshoe Efort nominal Rated strength (kN) 70 Cantitate (buc) Quantity (pcs) 1 1 1 1 1 Greutate Weight (kg) 0.492100 38

4

2

3

1

Denumire produs Label CTPF 120

Sectiune conductor Conductor size (mm) 50-70 / 90-120

121

5

LEA MT

12 / 13

LINII ELECTRICE AERIENE DE MEDIE TENSIUNE MEDIUM VOLTAGE OVERHEAD LINES

ARMATURI PENTRU LANTURI DE IZOLATOARE HARDWARE FOR MEDIUM VOLTAGE INSULATOR STRINGS Clema de sustinere cu alunecare controlata CSLAC / CSLAC clampUTILIZARE : lanturi de sustinere cu izolatoare MT

FIELD OF USE: suspension strings with composite insulators for medium voltagePoz Denumire reper / Component Cantitate (buc) Quantity (pcs) 1 1 1 1 1 1 1 1 1

1 2 3 4 5 6 7 8 9

Corp clema / Clamp body Parghie fixare Surub de torsiune Jgheab / Cradle Saiba plata A8 / Plain washer Bolt 12 x 45 / Bolt Saiba plata A 12 / Plain washer Agrafa (splint) 4 x 30/ Splint Stift filetat M 5 x 12 / Screwed pin

Denumire produs / Label CSLAC 50-70 / 90-120

Efort nominal Rated strength (kN) 70

Sectiune conductor Conductor size (mm) 50-70 / 90-120

Greutate Weight (kg) 0.445 / 0.45 13

Loc pt. marcare

Piesa rasucita PR 75 / Twisted pieceUTILIZARE : lanturi cu izolatoare MT, piesa de legatura intre armatura de prindere si jug FIELD OF USE: strings with composite insulators for medium voltage, Denumire produs Label PR 75 Efort nominal orizontal Orizontal rated strength (kN) 70 Greutate Weight (kg) 0,231 17 1x45

1x45

R 20

8

751 4.51

Piesa de distantare dubla PDD 55 / Double extension pieceUTILIZARE : lanturi de sustinere in V cu izolatoare MT14

Poz 1 2 3 4

Denumire reper / Component Bolt / Bolt Flansa Saiba A 16 / Washer Splint 4x30 / Splint

Cantitate (buc) Quantity (pcs) 2 2 2 2

3 4R 20 Loc pt. marcare

Denumire produs Label PDD 55

Efort nominal Rated strength (kN) 70

Greutate Weight (kg) 0.42

551 = = 951 = =

LEA MT

13 / 13

400,5

16

FIELD OF USE: V-shaped suspension strings with composite insulators for medium voltage

2

17

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESBLOCURI DE MASUR I PROTECIE MONOFAZATE MONOPHASE MEASUREMENT AND PROTECTION UNIT

DOMENII DE UTILIZARE Blocul de masur si protecie monofazat (BMPM), este destinat utilizrii n reeaua de distribuie final a furnizorilor de energie electric, asigur conexiunea dintre branamentul monofazat aerian sau subteran al furnizorului i coloana individual monofazat a instalaiei de utilizare a consumatorilor, avnd rolul de a contoriza consumul de energie electric i de a asigura protecia la scurtcircuit, suprasarcin, cureni de defect i supratensiune, implicit mpotriva sustragerilor de energie electric. SIMBOLIZARE / SIMBOL BMPM In, Crb, Ir, P, D, B, DPS-x, Xab unde BMPM - Bloc Masura si Protectie Monofazat In - curentul nominal / rated current Crb - caracteristica de funcionare / Tripping characteristics Ir - capacitatea de rupere a intreruptorului / rated breaking capacity P - numarul de poli ai intreruptorului / poles number D - protectie diferentiala / tripping protection B - bobina de declansare / shunt trip DPS-x - dispozitiv de protectie la supratensiune / over voltage Xab - nr abonati / users number

272 256

178 148

VARIANTE CONSTRUCTIVE UZUALE BMPM 25 A dif cu DPS- MN sau BMPM 32 A monopolar BMPM In cu DPS-MN - Blocul de masur si protecie monofazat ; cu protectie la suprasarcina si scurcircuit , optional cu protectie diferentiala , cu protectie la supratensiuni de frecventa industriala si intreruperea conductorului de nul DPS-MN - Dispozitiv de protecie la supratensiuni de frecven industrial cu monitorizarea nulului BMPM In cu DPS-01 - Blocul de masur si protecie monofazat ; cu protectie la suprasarcina si scurcircuit , optional cu protectie diferentiala, cu protectie la supratensiuni de frecventa industriala DPS- 01 - Dispozitiv de protecie la supratensiuni de frecven industrial - Blocul de masur si protecie monofazat ; cu protectie la suprasarcina si scurcircuit , optional cu protectie diferentiala

BMPM In

Toate tipurile de BMPM sunt executate din materiale electroizolante organice: partea inferioara din ABS, PC, PC cu fibra de sticla, iar capacul din PC transparent si pot fi realizate cu posibilitatea racordarii unui al doilea consumator , in derivatie. BMPM echipate cu DPS-MN sunt livrate cu priza de pamant tehnologica si conductorul de legatura a acesteia la BMPM.

LEA JT

1 / 22

340 290MOD DE COMANDARE :

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESCARACTERISTICI TEHNICE / TEHNICAL DATA Nr crt Caracteristici tehnice / Tehnical data Tip constructiv / Type BMPM In BMPM In BMPM In cu DPS-MN cu DPS-01 ST 3/2003 ST 3/2001 CS RENEL 660 V c.a 230 V 6; 10; 16; 20; 25; 32; 40; 45 A val. fix B sau C 10 kA 4.5, 6, 10 kA 4.5, 6,10 kA 1P, 1P+N, 2P 300 mA * minim 40.000 manevre (20.000 cicluri) minim 8.000 manevre (4.000 cicluri) 5C - 40C +55C -15C +40C 85% IP 65 Cutia - ABS, PC, PC+FS,PC transparent Capacul - PC transparent DPS-MN DPS-01 260 280 V 260 280 V 50 V 5V 0,2 sec 1A 1 sec 0,2 sec 1A 1 sec -

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 16.1 16.2 16.3 16.4 16.5 16.6 16.7 17 18

Normativ de referinta Tensiunea nominal de izolare / Rated insulation voltage Tensiune de utilizare / Operating voltage Curent nominal intreruptor / Rated current of cirtuit breaker Caracteristica de funcionare / Tripping characteristics Capacitatea de rupere a intreruptorului / Rated breaking capacity Numarul de poli ai intreruptorului / poles number Curent de defect /Rated tripping current Rezistena la uzur mecanic / Mecanical endurance Rezistena la uzur electric / Electrical endurance Temperatura de montaj / Mounting temperature Temperatura de lucru / Working temperature Temperatura de depozitare si transport / Storage and transport temperature Umiditatea relativ a aerului / Air relative humidity Grad de protectie / Protection degree Rezistenta mecanica / Mecanical rezistance Dispozitivul de protectie la supratensiune DPS Tensiune de actionare, msurat ntre faza i nulul de lucru Tensiune de retur pe nul msurat ntre nulul de lucru i pmnt Timpul de rspuns al ntreruptorului la apariia unei supratensiuni Curentul maxim (Imax) prin DPS-MN (la monentul comenzii de declanare): Timpul maxim de funcionare al DPS-MN la Imax.( n caz de defect al echipamentului mecanic de declanare al bobinei) Rigiditate dielectric Rezistenta de dispersie a prizei de pamant tehnologica (Rpa) Tipuri de contori posibili a fi montati in module Mod de anbalare

4 KV 4 KV 15 k Orice tip existent pe piata romaneasca Cutii de carton 1 buc / cutie

n toate situaiile n care modulul voltmetric (DPS-MN) a lucrat i a determinat declanarea disjunctorului (ID), funcionarea este semnalizat optic prin poziia prghiei de manevr a bobinei de declanare (ST). ATENTIE !!! Producatorii de intreruptoare automate diferentiale garanteaza buna functionare a acestora numai in cazul apasarii cel putin o data pe luna a butonului de Test al acestora.

LEA JT

2 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESSCHEME ELECTRICE DE PRINCIPIU/ ELECTRICAL CONNECTIONS Schema de principiu BMPM cu DPS-MN cf ST3/2003 Schema de principiu BMPM cu DPS-01 cf ST3/2001

Legenda: ST- shunt trip (bobina de declansare) ID- intreruptor automat diferential DPS-MN- dispozitiv de protectie la supratensiuni si monitorizare nul Schema de principiu BMPM cu intreruptor automat diferential

Legenda ID - Intreruptor magneto-termic si diferential DPS-01 - Dispozitiv de protectie la supratensiuni de frecventa industriala

Schema de principiu BMPM cu intreruptor automat monopolar

Legenda ID - Intreruptor magneto-termic si diferential bipolar/ 1P+N

Legenda I - Intreruptor automat monopolar

LEA JT

3 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESBLOCURI DE MASURA SI PROTECTIE TRIFAZATE THREE-PHASE MEASUREMENT AND PROTECTION UNITS Brevet OSIM nr 116131 B1 Certificat DMI nr 009501(1R); 009502(1R) UTILIZARE Blocurile de msur i protecie trifazate (BMPT) sunt echipamente specializate care fac parte integrant din branamentele trifazate ce reprezint o soluie modern i sigur de alimentare cu energie electric trifazat a micilor consumatori.. Ele au rolul de a contoriza consumul de energie electric activ reactiv i, la nevoie, aparent i de a asigura protecia la scurtcircuit, suprasarcin, cureni de defect i supratensiune, implicit mpotriva sustragerilor de energie electric. SIMBOLIZARE : BMPTd x/y z dif DPS-MN O unde BMPT - Bloc de msur i protecie trifazat; d - cu conectare direct a aparatelor de msur, sau i - cu conectare indirect a aparatelor de msur (prin transformatoare de curent); "x" - un numr specificnd curentul nominal al ntreruptorului trifazat; "y" - un numr specificnd curentul nominal al ntreruptorului monofazat, in cazul echiprii cu circuit monofazat; z - un numr (1, 2 sau 3) specificnd numrul de module destinate aparatelor de msur, astfel: 2a - dac se utilizeaz un singur contor trifazat pentru energie activ sau un contor cu funcii multiple tip ALPHA; 3ar - dac se utilizeaz doi contori trifazai, unul pentru energie activ i unul pentru energie reactiv, sau 3am - dac se utilizeaz un singur contor trifazat pentru energie activ sau un contor cu funcii multiple tip ALPHA i un contor monofazat pentru branamentul auxiliar monofazat; 4arm - dac se utilizeaz doi contori trifazai, unul pentru energie activ i unul pentru energie reactiv i un contor monofazat pentru branamentul auxiliar monofazat. dif - daca se doreste echiparea cu intreruptor automat diferenial; DPS-MN sau DPS-01-daca se dorete echiparea cu astfel de protectii la supratensiune; V - dac se dorete ca blocul s aib modulele dispuse pe vertical, sau O - dac se dorete ca blocul s aib modulele dispuse pe orizontal. MOD DE COMANDARE Exp: BMPTd 40A/25A 4arm dif DPS-MN. BMPT echipate cu DPS-MN sunt livrate cu priza de pamant tehnologica si conductorul de legatura a acesteia la BMPT. VARIANTE CONSTRUCTIVE : I - functie de numarul de module si de asezarea acestora : 1.280

BMPT 1a185

Aceasta varianta constructiva se poate folosi pentru blocurile in montaj direct, echipate cu intreruptor cu In 32 A, fara protectie diferentiala, cu sau fara protectie la supratensiune. Tip constructiv / Type BMPT In cu BMPT In cu BMPT In DPS-MN DPS-01 Masa neta (kg) 3.9 3,8 3,75

470

LEA JT

50

Masa data este fara cutie de ambalaj si fara priza de pamant tehnologica.

4 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINES2.BMPT 2a montaj orizontal570

BMPT 2a montaj pe verticala240280 240

470

BMPT 2a bloc prevazut cu doua module, unul pentru aparataj, celalalt pentru contorul de energie activa (de inductie), sau pentru contor electronic. Tip constructiv / Type BMPT In BMPT In BMPT In cu DPScu DPS-01 MN Masa neta 7.65 7,6 7,45 Net weight (kg) Masa data este fara cutie de ambalaj si fara priza de pamant tehnologica 3.BMPT 3ar (CA + CR)

50

860

240

470

BMPT 3ar bloc prevazut cu 3 module, unul pentru aparataj, unul pentru contor de energie activa (de inductie) si celalalt pentru contor de energie reactiva (de inductie). Tip constructiv / Type BMPT In cu BMPT In cu BMPT In DPS-MN DPS-01 Masa neta Net weight (kg) 11,55 11,4 11,35

Masa data este fara cutie de ambalaj si fara priza de pamant tehnologica

LEA JT

50

5 / 22

950

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESBMPT 3am cu DPS-MN pe ambele circuite

4

860

240

470

BMPT 3am bloc prevazut cu 3 module, unul de aparataj, unul pentru contorul trifazat de energie activa si unul pentru contorul monofazat

BMPT 3am50860

240

Masa neta Net weight (kg)

10.85

10.8

10.650

Masa data este fara cutie de ambalajBMPT 4arm (CA + CR + CM)

5.

570

240

BMPT 4arm bloc prevazut cu 4 module, unul pentru aparataj, 2 pentru contorii trifazici, de energie activa (de inductie) respectiv de energie reactiva (de inductie) si unul pentru contorul monofazat. Tip constructiv / Type BMPT In cu BMPT In cu BMPT In DPS-MN DPS-01 Masa neta 13.95 13.9 13.75 Net weight (kg) Masa data este fara cutie de ambalaj si fara priza de pamant tehnologica.

LEA JT

950

6 / 22

470

Tip constructiv / Type BMPT In cu BMPT In cu BMPT In DPS-MN DPS-01

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESNOTA Pentru BMPT cu montaj indirect, fata de cele enumerate mai sus, mai apare un modul pentru transformatorii de curent. II - functie de existenta si tipul dispozitivului de protectie la supratensiune : BMPT In cu DPS-MN - Bloc de msur i protecie trifazat; cu protectie la suprasarcina si scurcircuit, optional cu protectie diferentiala, cu protectie la supratensiuni de frecventa industriala si intreruperea conductorului de nul DPS-MN - Dispozitiv de protecie la supratensiuni de frecven industrial cu monitorizarea nulului BMPT In cu DPS-01 - Bloc de msur i protecie trifazat;cu protectie la suprasarcina si scurcircuit, optional cu protectie diferentiala, cu protectie la supratensiuni de frecventa industriala DPS- 01 - Dispozitiv de protecie la supratensiuni de frecven industrial - Bloc de msur i protecie trifazat; cu protectie la suprasarcina si scurcircuit, optional cu protectie diferentiala

BMPT In

CARACTERISTICI TEHNICE / TEHNICAL DATANr crt Caracteristici tehnice / Tehnical data Tip constructiv / Type BMPT In cu BMPT In cu BMPT In DPS-MN DPS-01 ST 4/2003 ST 4/2001 CS RENEL 660 V c.a 3 x 230 / 400 V 6; 10; 16; 20; 25; 32; 40; 63; 80; 100; 125; 160; 200 A* valoare fix C sau C 6 32 kA 3P, 3P+N, 4P minim 40.000 manevre (20.000 cicluri) minim 8.000 manevre (4.000 cicluri) 6; 10; 16; 20; 25; 32; 40; 63; 80; 100; 125; 160; 200; 250 A valoare fix 6 18 kA 300 mA 5C - 40C +55C -15C +40C 85% IP 54 Cutia- ABS, PC, PC+FS, PC transparent Capacul - PC transparent / ABS + PC DPS-MN DPS-01 260 280 V 260 280 V 50 V 5V 0,2 sec 0,2 sec 1A 1A 1 sec 1 sec -

1 2 3 4 5 6 7 8 9 9.1 9.2 9.3 10 11 12 13 14 15 16 16.1 16.2 16.3 16.4 16.5 16.6 16.7 17 18

Normativ de referinta Tensiunea nominal de izolare / Rated insulation voltage Tensiune de utilizare / Operating voltage Curent nominal intreruptor / Rated current of cirtuit breaker Caracteristica de funcionare / Tripping characteristics Capacitatea de rupere a intreruptorului / Rated breaking capacity Numarul de poli ai intreruptorului / poles number Rezistena la uzur mecanic / Mecanical endurance Rezistena la uzur electric / Electrical endurance Intreruptor automat diferential (optional) Curent nominal intreruptor / Rated current of cirtuit breaker Capacitatea de rupere a intreruptorului / Rated breaking capacity Curent de defect /Rated tripping current Temperatura de montaj / Mounting temperature Temperatura de lucru / Working temperature Temperatura de depozitare si transport / Storage and transport temperature Umiditatea relativ a aerului Grad de protectie / Protection degree Rezistenta mecanica / Mecanical rezistance Dispozitivul de protectie la supratensiune DPS Tensiune de actionare, msurat ntre faza i nulul de lucru Tensiune de retur pe nul msurat ntre nulul de lucru i pmnt Timpul de rspuns al ntreruptorului la apariia unei supratensiuni Curentul maxim (Imax) prin DPS (la monentul comenzii de declanare): Timpul maxim de funcionare al DPS la Imax.( n caz de defect al echipamentului mecanic de declanare al bobinei) Rigiditate dielectric Rezistenta de dispersie a prizei de pamant tehnologca (Rpa) Tipuri de contori posibili a fi montati in module Mod de ambalare

4 KV 4 KV 15 k Orice tip existent pe piata romaneasca Cutii de carton 1 buc / cutie

* Blocurile de 160, respectiv 200 A sunt echipate cu intreruptoare tip USOL. La cererea beneficiarului, pe cutia modulului de aparataj se poate monta: O born special de trecere, de mpmntare, la care se leag prin racord exterior centura de mpmntare, asigurndu-se legtura fizic ntre nulul de protecie i cel de lucru, sau O presetup PG 21 pentru a permite executarea legturii de nul direct n interiorul modulului de aparataj.

LEA JT

7 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESNOT IMPORTANT Prin adoptarea sistemului de construcie modular, rezult un BMPT extrem de flexibil. Din aceast cauz nu au fost precizate riguros poziiile presgarniturilor de intrare-ieire branament, nici poziia relativ a modulelor ntre ele. Clientul poate opta pentru o soluie clasic, la alegerea productorului (conform manualelor de utilizare prezentate) sau pentru orice configuraie specific dorit, iar productorul garanteaz c va rezolva n timp util opiunile acestuia. (De exemplu intrrile-ieirile pot fi asigurate prin partea superioar, inferioar sau lateralele BMPT, modulul de aparataj poate fi plasat n stnga sau n dreapta modulelor de msur sau, dup caz, sus/jos, structura de construcie a ntregului bloc poate fi realizat pe vertical sau orizontal etc.). Dat fiind deosebita flexibilitate a sistemului, clientul este rugat s specifice n clar opiunile sale sau s indice tipul de bloc conform manualelor prezentate. SCHEME ELECTRICE DE PRINCIPIU / ELECTRICAL CONNECTIONS 1. BMPT dif cu DPS-MN, fara circuit monofazat : cu protectie la suprasarcina, scurtcircuit, curenti diferentiali si supratensiuni de frecventa industriala, cu monitorizarea nulului.

LEA JT

8 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINES2. BMPT dif cu DPS-01, fara circuit monofazat : cu protectie la suprasarcina, scurtcircuit, curenti diferentiali si supatensiuni de frecventa industriala BMPT cu intr.aut. diferential si DPS-01 BMPT fara intr.aut.dif cu DPS-01

R S T N

Shunt trip

Disjunctor tripolar

DPS-01

DPS-01

Consumaror

3. BMPT dif fara circuit monofaz: cu protectie la suprasarcina si scurtcircuit si curenti diferentiali.

LEA JT

9 / 22

DPS-01

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINES4. Schema BMPT cu circuit monofazat cu protectie la suprasarcina, scurtcircit, curenti de defect si dispozitiv de protectie la supratensiune si monitorizare nul pe ambele circuite

NOTA Pentru variantele de echipare fara intreruptor diferential, din schema electrica de principiu se inlatura diferentialul.

LEA JT

10 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESFIRIDE DE DISTRIBITIE SI CONTORIZARE PALIER - FDCP FIRIDE DE DISTRIBUTIE SI CONTORIZARE CU PRINDERE PE STALP-FDCS MULTI BOXESFOR PROTECTION AND MEASUREMENT OF POWER DISTRIBUTION DOMENII DE UTILIZARE Firidele de distributie si contorizare sunt destinate utilizrii n reeaua de distribuie final a furnizorilor de energie electric, asigur conexiunea dintre branamentul aerian sau subteran al furnizorului i coloanele individuale monofazate ale instalaiei de utilizare a consumatorilor, avnd rolul de a contoriza consumul de energie electric i de a asigura protecia la scurtcircuit, suprasarcin, cureni de defect i supratensiune, implicit mpotriva sustragerilor de energie electric. SIMBOLIZARE / SIMBOL FDCP (S) Xab, In, Crb, Ir, P, D, B, DPS-x unde FDCP- Firida de Distributie si Contorizare Palier FDCS- Firida de Distributie si Contorizare cu prindere pe Stalp In - curentul nominal / rated current Crb - caracteristica de funcionare / Tripping characteristics Ir - capacitatea de rupere a intreruptorului / rated breaking capacity P - numarul de poli ai intreruptorului / poles number D - protectie diferentiala / tripping protection B - bobina de declansare / shunt trip DPS-x - dispozitiv de protectie la supratensiune / over voltage Xab - nr abonati / users number Toate tipurile de fride sunt executate din materiale electroizolante organice: partea inferioara din ABS, PC, PC cu fibra de sticla, iar capacul din PC transparent . MOD DE COMANDARE : FDCP 7ab 25 A dif cu DPS- 01 Firidele de distributie si contorizare tip FDCP 224 abonati , respectiv FDCS au o constructie modulara realizata din module de dimensiuni 420 x 280. Functie de numarul de abonati si spatiul de montaj disponibil , la cererea beneficiarului, se pot realiza si alte configuratii fata de cea standard propusa de producator. Firidele de tip FDCS sunt FDCP-uri prevazute cu bratari de prindere pe stalp si contrapanouri ce asigura rigidizarea mecanica a ansamblului.L190

Tip FDCP ( Nr. abonati) 2;3 4;5;6;7H

L 420 850 850 850 1280 1280 1280

H 620 620 910 1200 910 1200 1490

8;9;10 11;12;13 14;15;420 280

16;17;18;19;20; 21;22;23;24;

LEA JT

50

11 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESCARACTERISTICI TEHNICE / TEHNICAL DATANr crt Caracteristici tehnice / Tehnical data Tip constructiv / Type FDCP(S) In cu FDCP(S) In DPS-01 ST 3/2001 CS RENEL 660 V c.a 230 V 6; 10; 16; 20; 25; 32; 40; 45 A valoare fix B sau C 4.5, 6, 10 kA 1P, 1P+N, 2P 300 mA * minim 40.000 manevre (20.000 cicluri) minim 8.000 manevre (4.000 cicluri) 5C - 40C +55C -15C +40C 85% IP 54 Cutia- ABS, PC, PC+FS,PC transparent , capacul - PC transparent DPS-01 260 280 V 0,2 sec 1A 1 sec Orice tip existent pe piata romaneasca Cutii de carton 1 buc / cutie

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 16.1 16.2 16.3 16.4 17 18

Normativ de referinta Tensiunea nominal de izolare / Rated insulation voltage Tensiune de utilizare / Operating voltage Curent nominal intreruptor / Rated current of cirtuit breaker Caracteristica de funcionare / Tripping characteristics Capacitatea de rupere a intreruptorului / Rated breaking capacity Numarul de poli ai intreruptorului / poles number Curent de defect /Rated tripping current Rezistena la uzur mecanic / Mecanical endurance Rezistena la uzur electric / Electrical endurance Temperatura de montaj / Mounting temperature Temperatura de lucru / Working temperature Temperatura de depozitare si transport / Storage and transport temperature Umiditatea relativ a aerului Grad de protectie / Protection degree Rezistenta mecanica / Mecanical rezistance Dispozitivul de protectie la supratensiune DPS Tensiune de actionare, msurat ntre faza i nulul de lucru Timpul de rspuns al ntreruptorului la apariia unei supratensiuni Curentul maxim (Imax) prin DPS (la monentul comenzii de declanare): Timpul maxim de funcionare al DPS la Imax Tipuri de contori posibili a fi montati in module Mod de anbalare

n toate situaiile n care modulul voltmetric DPS a lucrat i a determinat declanarea disjunctorului (ID), funcionarea este semnalizat optic prin poziia prghiei de actionare a acestuia sau prin poziia prghiei de manevr a bobinei de declanare (ST) in cazul echiparii cu intreruptoare monopolare.

ATENTIE !!! Producatorii de intreruptoare automate diferentiale garanteaza buna functionare a acestora numai in cazul apasarii cel putin o data pe luna a butonului de Test al acestora. SCHEME ELECTRICE DE PRINCIPIU / ELECTRICAL CONNECTIONS 1. FDCP dif cu DPS-01 : cu protectie la suprasarcina, scurtcircuit , curenti diferentiali si la supratensiuni de Retea frecventa industriala.R S T N

Conector de nul

DPS-01

RCB max 32A

Celula Celula abonat abonat 3 2 kwh

Celula Celula Celula abonat abonat abonat 6 4 5

Celula abonat 1

Celula abonat n

Spre abonat 1

Spre abonat i

LEA JT

12 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINES2. FDCP monopolar cu DPS-01 : cu protectie la suprasarcina, scurtcircuit si la supratensiuni de frecventa industriala.R S T N Retea

Conector de nul

C1 BD C2

DPS-01

MCB max 32A

Celula abonat 2

Celula abonat 3

Celula abonat 4

Celula Celula abonat abonat 5 6

Celula abonat n

Celula abonat 1

kwh

3. FDCP cu monopolar : cu protectie la suprasarcina, scurtcircuit ,R S T N Retea

Conector de nul

Celula abonat 1MCB max 32A

Celula Celula Celula Celula Celula abonat abonat abonat abonat abonat 3 4 5 6 2

Celula abonat n

kwh

Spre abonat 1

Spre abonati

LEA JT

13 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESCLEME SI ACCESORII PENTRU BRANSAMENTE CLAMPS AND ACCESSORIES FOR BRANCHINGS Cap. 1 CLEME DE DERIVATIE CU DINTI INSULATION PIERCING CONNECTORS Clemele produse de firma noastra sunt superioare produselor similare de pe piata datorita urmatoarelor caracteristici: permit realizarea legaturii electrice pe orice tip de conductor (aluminiu, cupru, unifilar sau multifilar) datorita materialelor utilizate si a tehnologiei speciale de acoperire folosite pentru fabricarea dintilor potentialul electrochimic este practic egal atat pentru cupru cat si pentru aluminiu. rezistenta mecanica net superioara si fiabilitate sporita in exploatare datorita materialelor folosite pentru carcase si capete de surub. asigura un montaj sigur in exploatare si usor de realizat. CDD45 SIMBOLIZARE / SYMBOL CDD Clema derivatie cu dinti pentru bransament / Insulation Piercing Connector 45 curent nominal / rated current UTILIZARE / USE Este utilizata in liniile electrice de joasa tensiune pentru realizarea derivatiilor de bransamente cu conductori de Al sau Cu, din conductoarele fascicolelor torsadate cu sectiuni de pana la 35 mm fara desizolarea acestora.

Sectiune conductor principal Main conductor size (mm) 16 35 Al izolat;

Sectiune conductor derivat Branch conductor size (mm) 6 10 Cu 6 25 Al

Cuplul de strangere Torque couple (Nm) 1315

Greutate Weight (kg) 0,112

Ambalare (buc/cutie) Packing (pcs/box) 40 sau 100

Ambalarea se face in cutii de carton.

CDDM SIMBOLIZARE / SYMBOL CDD Clema derivatie cu dinti Insulation Piercing connector M- Modernizata Improved UTILIZARE / USE Este utilizata in liniile electrice de joasa tensiune pentru realizarea derivatiilor de bransamente cu conductori de Al sau Cu, din conductoarele fascicolelor torsadate cu sectiuni mari fara desizolarea acestora.

LEA JT

14 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINES

Sectiune conductor Sectiune conductor principal derivat Main conductor size Branch conductor size (mm) (mm) 50 95 Al izolat; 50/8 6 10 Cu Al-Ol izolat 6 25 Al Ambalarea se face in cutii de carton. CDDCN

Cuplul de strangere Torque couple (Nm) 1720

Greutate Weight (kg) 0,165

Ambalare (buc/cutie) Packing (pcs/box) 75

SIMBOLIZARE / SYMBOL CDD-CN - Clema de Derivatie cu Dinti pentru Conductor Neizolat / Connection Clamp for copper coaxial from uninsulated conductors UTILIZARE / USE Este destinata asigurarii legaturii electrice intre un conductor principal de transport pentru energie electrica, neizolat, si un conductor izolat al unui cablu de bransament. Ambalarea se face in cutii de carton.

Sectiune conductor principal Main conductor size (mm) 25 70 Al neizolat;

Sectiune conductor derivat Branch conductor size (mm) 6 10 Cu 6 25 Al

Cuplul de strangere Torque couple (Nm) 1315

Greutate Weight (kg) 0,112

Ambalare (buc/cutie) Packing (pcs/box) 40/100

CDDLP SIMBOLIZARE / SYMBOL CDDLP -Clema de Derivatie cu Dinti pentru Linie Principala / Main Line Insulation Piercing Connector UTILIZARE / USE Asigura derivarea retelei torsadate de distributie a energiei electrice de joasa tensiune din reteaua principala, fara sectionarea conductorului liniei principale, utilizand numai o cheie tubulara de 13 mm.

Sectiune conductor Sectiune conductor principal derivat Main conductor size Branch conductor size (mm) (mm) 35 95 Al izolat; 50/8 35 95 Al izolat; 50/8 Al-Ol izolat Al-Ol izolat Ambalarea se face in cutii de carton.

Cuplul de strangere Torque couple (Nm) 1820

Greutate Weight (kg) 0,246

Ambalare (buc/cutie) Packing (pcs/box) 25

LEA JT

15 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESCDDIL SIMBOLIZARE / SYMBOL CDDIL -Clema de Derivatie cu Dinti pentru Iluminat / Insulation Piercing Connector for lamp connection UTILIZARE / USE Asigura alimentarea cu energie electrica a corpurilor de iluminat public, de la reteaua aeriana mono sau trifazata, executata cu cablu torsadat sau conductoare izolate, fara sectionarea acestora.

Sectiune conductor principal Main conductor size (mm) 25 50 Al izolat;

Sectiune conductor derivat Branch conductor size (mm) 1.5 6 Cu izolat ; 4 6 Al izolat

Cuplul de strangere Torque couple (Nm) 810

Greutate Weight (kg) 0,109

Ambalare (buc/cutie) Packing (pcs/box) 40/100

Ambalarea se face in cutii de carton.

Cap 2. CLEME DE INTINDERE / DEAD-END CLAMPS2.1. CLEME DE INTINDERE BRANSAMENT / DEAD-END CLAMPS FOR BRANCHING CIB I, CIB II - Clema Intindere Bransament Certificat DMI nr 004855(1R); 004858(1R) Dead-End Clamp for bundled or coaxial conductors UTILIZARE Clema de intindere pentru bransament electric CIB este destinata executarii bransamentelor electrice monofazate, mai precis pretensionarii fascicolului de conductoare torsadate respectiv, cablul coaxial ce face legatura intre punctul de bransament si punctul de masura (BMPM). Pentru a se asigura intreaga gama nominalizata de sectiuni de conductoare se utilizeaza doua tipuri de miezuri, respectiv un miez de forma stelata (CIB I) pentru conductoare monofilare si un set de pene semirotunde (CIB II) pentru cablu coaxial. Sectiune conductor Al Aluminium Conductor Size (mm) 1025 Sectiune conductor Cupru Copper Conductor Size (mm) 610 Rezistenta tractiune Rated Strength (daN) 100 100 Efortul de rupere Ultimate Strength (daN) 200 200

Tip clema Clamp Type CIB I CIB II

Greutat e Weight (kg) 0,15 0,16

Ambalare (buc/cutie) Packing (pcs/box) 50 50

LEA JT

16 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESCIBMU - Clema Intindere Bransament Monofazat Universala- Brevet RO114848 Universal Dead-End Clamp for bundled or coaxial conductors UTILIZARE Clema de intindere bransament monofazat universala tip CIBMU este conceputa pentru utilizarea in bransamente monofazate executate cu orice tip de cabluri normate (aluminiu sau cupru, torsadate sau concentrice), pentru orice puteri normate (1,510 KW), respectiv pentru orice sectiune de 2 cablu utilizabila (2x62x25 mm ). Cand se utilizeaza cablu concentric sau cablu bifilar pentru ghirlande luminoase, acesta se plaseaza intre cele doua pene si se introduce, impreuna cu acestea, in corp. Se fixeaza cercelul. Prin tragerea cablului se asigura fixarea prin impanare. Cand se utilizeaza cablu torsadat, cele doua conductoare ale cablului se plaseaza pe partile laterale ale penelor si impreuna cu acestea se introduc in corp. Prin tragere se asigura fixarea prin impanare. Avantaj principal:Poate asigura intinderea cablurilor, fara sectionarea lor si intre stlpi intermediari. Similar, poate fi inlocuit oricnd fara nici un efort, deoarece nu necesita tragerea pe cablu ca in cazul clemelor tubulare. In plus, prin constructia deosebit de robusta, depaseste net din punct de vedere al rezistentei mecanice toate clemele cu pene existente in tara.

Sectiune conductor Aluminiu Aluminium Conductor Size (mm) 1025

Sectiune conductor Cupru Copper Conductor Size (mm) 610

Rezistenta tractiune Rated Strength (daN) 100

Efortul de rupere Ultimate Strength (daN) 200

Greutate Weight (kg) 0,16

Ambalare (buc/cutie) Packing (pcs/box) 50

CIBT - Clema de Intindere Bransament Trifazat / Dead-End Clamp for 2 or 4 wires Certificat DMI nr 010405(1R); 010406(1R); 010407(1R) UTILIZARE Clemele de intindere bransament electric trifazat trebuie sa permita racordarea si intinderea conductoarelor izolate din compunerea retelelor executate cu conductoare torsadate. La intinderea bransamentelor monofazate se plaseaza conductoarele pe o singura fata a clemei. In locasul ramas liber se introduce fortat pana aferenta pentru a preveni aparitia in timp a cuplurilor de rupere prin incovoiere a clemei datorate incarcarii nesimetrice a acesteia. Pentru a se asigura intreaga gama nominalizata de sectiuni de conductoare se utilizeaza doua tipuri de pene de strngere, 2 respectiv un set de pene mai late pentru sectiuni de 6, 10 si 16 mm sau un set de pene mai inguste pentru sectiuni mai mari.

Tip CIBT Clamp Type

Sectiune conductor TYIR Conductor Size (mm) 2 x 6 4 x 16 2 x 25 4 x 35 3 x 35 + 50 OlAl.

Rez. nom. la tractiune Rated Strength (daN) 150

Efort de rupere Ultimate Strength (daN) 300

Greutat e Weight (kg) 0,29 0.27

Ambalare (buc/cutie) Packing (pcs/box)

CIBT 1 (pene late) / (wide wedges) CIBT 2 (pene inguste) / (narrow wedges) 2 2 x 6 mm Al

40

LEA JT

17 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINES2.2 CLEME DE INTINDERE RETEA DEAD-END TENSION CLAMP CIR Clema Intindere Retea Dead-End Tension Clamp UTILIZARE Clema de intindere retea se utilizeaza la intinderea conductoarelor pe stalpi, in tandem cu clemele de legatura electrica tip CLE.

Sectiune conductor Aluminiu Aluminium Conductor Size (mm) CIR 750 1670

Sectiune conductor nul Ol-Al Neutral Conductor Size (mm) 1 x 50

Rezistenta la tractiune Rated Strength (daN) 750

Greutate Weight (kg) 0,31

Ambalare (buc/cutie) Packing (pcs/box) 30

Cap 3. ACCESORII DE BRANSAMENT BRANCHING ACCESSORIESSUPORT CU BRATARA SI CARLIG, PENTRU BRANSAMENT - SBCB / SUSPENSION HOOK BRACKET FOR BRANCHING Simbolizare / Symbol: SBCB 1, L=2.5 m SBCB- suport cu bratara si carlig pentru bransament / Suspension hook bracket for branching 1 - marimea tevii zincate / size of the zinc-plated pipe L=2.5 m lungimea tevii zincate / lengths of the zinc-plated pipePoz 1 2 3 4 5 6 Denumire reper Reference Cap stender / Pipe closer Bratara cu carlig / Pipe clip Guler etansare / Water proof collar Bratara fixare / Fixing clip Teava zincata / Zinc-plated pipe Tub Berman / Berman tube Cantitate Quantity (buc) 1 1 1 2 1 1

Variante constructive / Types: pt. tevi de 1 si 2 / for 1 and 2 pipes pt. lungimi ale tevii L= 1.5; 2.5; 3; 4 m / for pipe lengths CAP STENDER - CS 1 1/2, 2PIPE CLOSER

Simbolizare / Symbol: CS : Cap Stender / Pipe Closer 1; 2 : diametrul stenderului (tevii de protectie, din otel) / the diameter of the protective steel piped (mm) CS 1 CS 2 39 52 Greutate Weight (kg) 0.068 0,07 Ambalare (buc/cutie) Packing (pcs/box) 50 50

LEA JT

18 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESBRATARA CU CARLIG PENTRU SUPORT BRANSAMENT - SBCB-01 / SUSPENSION HOOK BRACKET FOR BRANCHINGSEfort nominal orizontal Orizontal rated strength (daN) SBCB-01 100 Greutate Weight (kg) 0,268 Ambalare (buc/cutie) Packing (pcs/box) 50

BRATARA FIXARE PENTRU SUPORT BRANSAMENT - SBCB-02 SUSPENSION ASSEMBLYGreutate Weight (kg) SBCB-02 0,106 Ambalare (buc/cutie) Packing (pcs/box) 50

INEL INCASTRAT IN ZID IBIZ WALL BUILT-IN COLLARL (mm) Length IBIZ 140 l (mm) Width 60 Efort nominal orizontal Orizontal rated strength (daN) 100 Greutate Weight (kg) 0. 213 Ambalare (buc/cutie) Packing (pcs/box) 50 67 53.9 47.9 15 5

GULER ETANSARE GET WATER PROOF COLLAR

59.7

Greutate Weight (kg) GET 0,137

Ambalare (buc/cutie) Packing (pcs/box) 50

115

Cap 4 ACCESORII PENTRU LEA JT ACCESSORIES FOR LOW VOLTAGE OVERHEAD LINES

ANSAMBLU DE PRINDERE PE STALP CU BRATARA AUB /tip stalp / PILE GRIPPING BRACKET ASSEMBLYStalpi vibratiprecomprimati / Vibratedprestressed piles SE 4 SE 10 SE 11 Stalpi centrifugati / Centrifugallycast piles SC 10.001 SC 10.002 SC 10.005

a (mm) 180 265 325

b (mm) 215 370 430

R (mm) 80 130 138

LEA JT

19 / 22

127.3

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESBRATARA DE SUSTINERE BRANSAMENT BBS/ tip stalp BRANCHING SUSPENSION BRACKETStalpi vibratiprecomprimati Vibratedprestressed piles SE 4 SE 10 SE 11 Stalpi centrifugati Centrifugallycast piles SC 10.001 SC 10.002 SC 10.005 TC 15.014

a (mm) 180 265 325

b (mm) 215 370 430

D (mm) 170 265 285 380

CONSOLA DE SUSTINERE CU BRATARA CSB /tip stalp SUSPENSION BRACKETStalpi vibratiprecomprimati Vibratedprestressed piles SE 4 SE 10 SE 11 Stalpi centrifugati Centrifugallycast piles SC 10.001 SC 10.002 SC 10.006 TC 15.014

a (mm) 170 272 325

b (mm) 170 310 400

D (mm) 160 250 270 380

CONSOLA DE SUSTINERE CS 300 / SUSPENSION CONSOLEEfort nominal orizontal Orizontal rated strength (daN) 100 Efort nominal vertical Vertical rated strength (daN) 250 Greutate Weight (kg) 0. 741

CS 300

ANSAMBLU DE PRINDERE PE STALP AU 750 PILE GRIPPING ASSEMBLYEfort nominal orizontal Orizontal rated strength (daN) 750 Greutate Weight (kg) 0,71

AU 750

INTINZATOR RETEA IR 750 / DEAD-END HOOKS Efort nominal orizontal Orizontal rated strength (daN) 750 Greutate Weight (kg) 0.63

IR 750

PRELUNGITOR P 750 / EXTENSION PIECE Efort nominal orizontal Orizontal rated strength (daN) 750 Greutate Weight (kg) 0.56

P 750

LEA JT

20 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESTIFA FILETATA TF / SCREWED RODL (mm) TF SE 4 TF SE 10 TF SE 11 240 350 400 Efort nominal orizontal Orizontal rated strength (daN) 1100 Greutate Weight (kg) 0.255 0.367 0,378

TIJA DE INTINDERE TI / TENSION HOOKA (mm) TI SE 4 TI SE 10 TI SE 11 200 300 350 B (mm) 260 360 410 Efort nominal orizontal Orizontal rated strength (daN) 1100

TIJA DE SUSTINERE TS / SUSPENSION HOOKA (mm) TS SE 4 TS SE 10 TS SE 11 250 350 400 B (mm) 330 430 480 Efort nominal orizontal Orizontal rated strength (daN) 1100

ARMATURA DE SUSTINERE IN COLT ASC 1100 CORNER SUSPENSION CLAMPEfort nominal Rated strength (daN) ASC 1100 1100 Sectiune max fascicul conductoare Max. section of conductors bundle (mm) 3x95 + 2x16 Al izolat, 50/8 Ol-Al izolat Greutate Weight (kg) 0,293 Ambalare (buc/cutie) Packing (pcs/box) 25

ARMATURA DE SUSTINERE ALINIAMENT ASA 300 , ASA 600 SUSPENSION CLAMPEfort nominal Rated strength (daN) ASA 300 ASA 600 300 600 Sectiune fascicul conductoare Max Max. section of conductors bundle (mm) 3x95 + 2x16 Al izolat, 50/8 Ol-Al izolat 3x95 + 2x16 Al izolat, 50/8 Ol-Al izolat Cantitate Quantity (buc)/(pcs) 1 1 1 Greutate Weight (kg) 0,144 0,293 Ambalare (buc/cutie) Packing (pcs/box) 25 30 - 4058 165

3

2

1

Poz 1 2 3

Denumire reper / Component Corp Suport metalic Agatatoare

LEA JT

21 / 22

LINII ELECTRICE AERIENE DE JOASA TENSIUNE LOW VOLTAGE OVERHEAD LINESCLEMA DE LEGATURA ELECTRICA- CLE 50-70, CLE 50-70 S / ELECTRIC CONNECTON CLAMPEfort nominal Rated strength (daN) CLE 50-70 1100 Sectiune conductor Conductor size (mm) 50 - 70 Greutate Weight (kg) 0,195 Ambalare (buc/cutie) Packing (pcs/box) 54 Cantitate Quantity (buc)/(pcs) 2 3 3 3 3

Poz 1 2 3 4 5

Denumire reper / Component Bac / Can Saiba speciala / Special washer Saiba grower M 8 / Spring washer Surub cap hex M 8x40 / Hexagon cap screw Piulita M 8 / Nut

CLEMA DE ALUNECARE CA / SLIDING CLAMPEfort nominal Rated strength (daN) CA 50-70 1100 Sectiune conductor Conductor size (mm) 50 - 70 Greutate Weight (kg) 0.067 Ambalare (buc/cutie) Packing (pcs/box) 50

Poz 1 2 3 4 5 6

Denumire reper / Component Bac inferior / Bottom can Bac superior / Top can Piulita calibrata / Gauged nut Saiba plata A 8 / Plain washer Saiba grower N 8/ Spring washer Surub cap hex M 8x40/ Hexagon cap screw

Cantitate Quantity (buc)/(pcs ) 1 1 1 1 1 1

CLEMA DE BLOCARE CB / BLOCKING CLAMPEfort nominal Rated strength (daN) CB 50-70 1100 Sectiune conductor Conductor size (mm) 50 - 70 Greutate Weight (kg) 0.07 Ambalare (buc/cutie) Packing (pcs/box) 50

Poz 1 2 3 4 5

Denumire reper / Component Bac / Can Surub cap hex M 8x40/ Hexagon cap screw Saiba speciala MR/ Special Washer Saiba grower N 8/ Spring Washer Piulita hexagonala M8 / Hexagon nut

Cantitate Quantity (buc)/(pcs) 1 1 1 1 1

LEA JT

22 / 22