    Typ Notifctn Notif.date EquipmentBD

    typeDescription MalfStrt Malf.end

    Downti

    meCause Wor

    M2 10135873 01.08.2013 8STN-403 E motor not run 13:30:00 15:30:00 2Motor fan not working, so motor

    heated up

    Changed

    down th

    M2 10135869 01.08.2013 8STN-403 E motor power short 10:30:00 12:00:00 1.5 Motor heated up so MCB trippedReset M

    shorting

    M2 10135441 01.08.2013 H-402 M spindle sound prob. 13:30:00 14:00:00 0.5 wedge got stuckremove

    done

    M2 10135872 01.08.2013 SRG-403 E single phase alarm 11:10:00 12:40:00 1.5one phase missing for A axis servo

    motor for roatry from amplifier

    Checkedcontinui

    motor si

    M2 10135867 01.08.2013 SVM-402 E x axes, y axes & z axes alarm 11:10:00 12:00:00 0.83VRDY alarm repeated , Z axis

    motor heated up

    Checked

    coupling

    cable wi

    M2 10135874 02.08.2013 8STN-403 Eback chamfer motor trip

    prob.13:45:00 14:00:00 0.25

    Motor heated up and found play in

    spindle shaft

    Remove

    checked

    motor sh

    M2 10135829 04.08.2013 SHD-403 M air pressure high & low 20:20:00 20:30:00 0.17Air pressure low as Nitrogen plant

    runStarted

    M2 10135824 05.08.2013 H-402 M sound prob. 10:20:00 10:30:00 0.17 y-clamp bolt loose y-clamp

    M2 10135823 05.08.2013 H-403 E spindle not run 16:30:00 17:20:00 0.83 belt damaged Belt cha

    M2 10135875 05.08.2013 SVM-402 M

    hydraulic pressure gauge

    offset/ rotary switch for

    h draulic ressure aua e

    15:30:00 17:15:00 1.75

    Roatry switch for hydraulic

    pressure gauge not working due to

    one o-rin found dama ed

    changed

    disment

    M2 10135825 07.08.2013 H-403 M break shoo broken 7:50:00 8:50:00 1 clutch liner loose changed

    M2 10135831 07.08.2013 H-404 Eboth m/c power connection

    on panel7:40:00 9:20:00 1.67

    Motor connection loose so motor

    heated uprepaired

    M2 10135830 07.08.2013 H-405 E motor not working 7:40:00 9:20:00 1.67Motor connection loose so motor

    heated uprepaired

    M2 10135879 07.08.2013 SRG-401 E rotary over heat alarm 21:45:00 23:00:00 1.25

    coolant entered inside rotary

    motor due to parralism upset and

    coolant leaka e from there

    Remoev

    and dry

    cover on

    M2 10135878 07.08.2013 SVM-402 E indexing prob. 8:00:00 9:10:00 1.17Limit switch signal not coming due

    to element stucked inside

    Changed

    damage

    M2 10135826 08.08.2013 8STN-404 M back chamfer spindle prob. 0:20:00 0:45:00 0.42 belt wear out due to wet condition change t

    M2 10135828 08.08.2013 8STN-404 E power trip prob. 12:03:00 12:23:00 0.33NC tripping problem due to lamp

    connection choke shorted

    Remove

    changed

    M2 10135832 08.08.2013 H-405 bush not ok 8:30:00 9:00:00 0.5 cylinder fittment space problem sheet gr

    M2 10136372 08.08.2013 M-401 running time spindle stop 4:00:00 22:30:00 18.5 Spindle rotation gears bolt broken Remove

    M2 10135833 08.08.2013 SHD-403 M air pressure low 12:30:00 12:40:00 0.17 vary from FRL FRL set

    M2 10135891 08.08.2013 SVM-401 M Spindle belt broken 16:30:00 17:20:00 0.83 belt ribs cut belt cha

    M2 10135827 09.08.2013 8STN-404 M belt slip prob. 0:30:00 1:00:00 0.5Belt wear out of 6th head

    backchamferChanged

  • 7/29/2019 iw29new aug-13 (1)

    2/15

    M2 10135902 09.08.2013 CLTAP-401 M spindle offset 12:50:00 13:00:00 0.17 footpaddle problem repaired

    M2 10135895 09.08.2013 SRG-401 M rotary prob. 10:20:00 10:40:00 0.33Variation in component due to

    rotary axis coupling slip down

    Changed

    ETP-22 a

    M2 10135892 09.08.2013 SVM-402 E enter down reason alarm 7:30:00 9:30:00 2Ethernet adopter was creating

    problem and hanged

    Remoev

    line TPM

    Etherne

    M2 10135905 10.08.2013 SHH-401 M home position forget prob. 10:10:00 10:30:00 0.33 Encoder cable loose Tightene

    M2 10136373 10.08.2013 SVM-403 E air sensor not on 10:45:00 11:10:00 0.42 air sensor faulty changed

    M2 10136396 11.08.2013 SRG-404 E x.y.a. delete alarm 7:00:00 7:40:00 0.67

    Softkeys not working due to oil

    and so wrong data feeded in

    machine

    Cleaned

    checked

    LCD scre

    M2 10136397 13.08.2013 SHH-401Cycle start push button not

    working13:40:00 13:50:00 0.17 NC element creating problem Changed

    M2 10136380 14.08.2013 H-403 M spindle prob. 7:30:00 8:50:00 1.33Spindle not taking load due to

    push rod moutning loosetightene

    M2 10136395 16.08.2013 8STN-404 M spindle jam prob. 19:30:00 20:00:00 0.5

    Found spindle moving very tight

    and with sound as its face cover

    one bolt was not sittin ro erl in

    Lossene

    changed

    M2 10136394 16.08.2013 H-403 M spindle not stop prob. 12:45:00 13:30:00 0.75Wedge not coming outside due toone cylinder mounting was

    creatin roblem and not workin

    Repaired

    and set t

    M2 10136405 16.08.2013 SHD-403 M air pressure low 16:30:00 16:40:00 0.17Air pressure low as Nitrogen plant

    runStarted a

    M2 10136398 16.08.2013 SVM-401 M clamping prob. 12:10:00 12:25:00 0.25 coil connection loose connect

    M2 10136950 17.08.2013 8STN-405 M belt slip prob. In 2nd head 7:20:00 11:40:00 4.33

    Found belt in ok condition, but

    RPM slow down during running

    cycle

    Changed

    remain s

    side ( mo

    M2 10136951 17.08.2013 H-403 M spindle not stop 0:10:00 1:00:00 0.83 brake shoe bolt setting disturbed bolt sett

    M2 10136957 17.08.2013 H-404 E both m/c power connectionconnect

    7:00:00 7:40:00 0.67 mpcb faulty of h-405 as both m/cconnected with same mcb

    changed

    M2 10136956 17.08.2013 H-405 M spindle not run 7:00:00 10:30:00 3.5

    Spindle motor heated up due to

    single phasing from MCB pole

    fault and heav sound

    Changed

    and cha

    M2 10136959 17.08.2013 SFB-401 Mslide cover broken(Aprin

    cover for ball screw)22:15:00 22:30:00 0.25

    Aprin cover for ball screw

    protection damaged as during tool

    chan e force on a rin cover is

    Repaired

    prod pe

    M2 10136958 17.08.2013 SHD-403 M chamfer more prob. 14:30:00 15:00:00 0.5 Air pressure vary during operationSet the a

    regulato

    M2 10136952 18.08.2013 H-403 spindle not stop 9:00:00 9:10:00 0.17 brake shoe bolt setting disturbed bolt sett

    M2 10136966 19.08.2013 SHH-401 y axis home position forget 14:05:00 14:30:00 0.42Checked and found that encoder

    connector loosetightene

    M2 10136954 23.08.2013 H-403 M load prob. 13:30:00 15:00:00 1.5 Cluthc liner not working changed

    M2 10136953 23.08.2013 SHH-403 M pulls miss alarm 12:00:00 12:10:00 0.17 Load on spindle released

    M2 10136962 23.08.2013 SVH-401 M abnormal sound prob. 11:00:00 11:10:00 0.17Sound came from Hydraulic pump

    unit

    Checked

    level , m

  • 7/29/2019 iw29new aug-13 (1)

    3/15

    M2 10138708 25.08.2013 8STN-404 M spindle not run 18:50:00 19:30:00 0.67spindle pulley bolt open and stuck

    in belt and pulley

    remove t

    properly

    M2 10138766 26.08.2013 8STN-404 M coolant bud broken 16:30:00 17:00:00 0.5

    one spiral coolant bud broken due

    to frequent motion on toll for

    coolant setting

    Repaired

    for new o

    M2 10138767 26.08.2013 8STN-405 E power trip prob, 17:10:00 17:30:00 0.33 relay malfunctioning relay cha

    M2 10138952 26.08.2013 DDG-401 Evoltage stabilizer

    modification8:10:00 8:30:00 0.33

    steplizer not working in auto mode

    due to card problemso setting

    M2 10138768 26.08.2013 H-403 M spindle jam prob. 21:50:00 22:15:00 0.42spindle coupling got shift due to

    bolt loose

    so tightne

    properly

    M2 10138951 26.08.2013 SHD-403 M air pressure low 7:30:00 7:40:00 0.17 vary from FRL set the F

    M2 10138939 27.08.2013 SRG-401 Erotary prob.(jerking in

    rotary)18:00:00 18:40:00 0.67 Checked and found belt may sl ip

    Checked

    under ob

    M2 10138765 27.08.2013 SVM-401 M run out prob. 7:50:00 8:15:00 0.42Bellow coupling may cause the

    problem

    Changed

    19x20

    M2 10138941 29.08.2013 8STN-403 E a axis o.v.c. alarm 17:15:00 18:10:00 0.92tap head play due to spindle pulley

    key wear outchange th

    M2 10138935 29.08.2013 H-402 m belt broken 21:45:00 0:00:00 0 belt broken belt chna

    M2 10138934 29.08.2013 SVM-403 M hydraulic pressure low 17:15:00 18:00:00 0.75Hydraulic pressure reduced in

    pumpSet the p

    M2 10138938 30.08.2013 DAM-407 E clamp declamp prob. 3:30:00 3:50:00 0.33 NO-elemnt malfunctioning change th

    M2 10138943 31.08.2013 SRG-403 M foot pedal not working 13:40:00 13:50:00 0.17Foot padel wiring loose from

    insideTightene

    M2 10138945 31.08.2013 SVM-402 Epower not available in panel

    /LCD17:15:00 18:40:00 1.42

    Electrical Shorting of 24 V DC

    electrical panel due to one wire

    cut and touched with bod

    Cut nd re

    58

    92

    50600

    63.21

    1.089827586

    872.4137931

    Frequency

    Total m/c

    total available

    hrs.

    Total Break

    down Hrs.

    MTTR

    MTBF

  • 7/29/2019 iw29new aug-13 (1)

    4/15

    M/C code BD hrs.

    SM-401 18.5

    SVM-402 7.17

    H-403

    H-405

    8STN-403 168STN-405 4.66

    8STN-404 2.92

    H-404

    SRG-401 2.25

    SRG-403 1.67

    SVM-401 1.5

    SHD-403 1.18

    SVM-403 1.17

    SHH-401 0.92

    H-402 0.67SRG-404 0.67

    DAM-407 0.33

    DDG-401 0.33

    SFB-401 0.25

    CLTAP-401 0.17

    SHH-403 0.17

    SVH-401 0.17

    60.7

    M/C code OccurancesH-403 8

    8STN-404 6

    SVM-402 5

    SHD-403 5

    8STN-403 4

    H-405 3

    SRG-401 3

    SVM-401 3

    SHH-401 3

    8STN-405 2H-404 2

    SRG-403 2

    SVM-403 2

    H-402 2

    SM-401 1

    SRG-404 1

    DAM-407 1

    DDG-401 1

    18.5

    7.17

    16

    4.6

    0

    2

    4

    6

    8

    10

    12

    14

    16

    18

    20

    8

    6

    5 5

    4

    3

    1

    2

    3

    4

    5

    6

    7

    8

    9

    Nos.

    1. 18.5 Hrs. - Gear unitbolts broken- changedbolt

    Hrs.

  • 7/29/2019 iw29new aug-13 (1)

    5/15

    SFB-401 1

    CLTAP-401 1

    SHH-403 1

    SVH-401 1

    58

  • 7/29/2019 iw29new aug-13 (1)

    6/15

    6

    2.922.25

    1.67 1.5 1.18 1.17 0.92 0.67 0.67 0.33 0.33 0.25 0.17 0.17 0.17

    BD hrs.- Aug-13 BD hrs.

    1. Clutch liner not working due tofaceplate damaged/rubbed- rpetaed

    problem- will take in reconditioningafter installation of Ingish machine

    1. 2 hrs. -Enterdown reason came for OnlineTPM - ethernet adopter was creating problem-

    removed at time and changed.

    2. 1.75 Hrs. - Hydraulic gauge rotaryswitch not working- found o-ringdamaged inside-changed3. 1.42 Hrs. - Shorting in electrical 24v DC -one cable foun cut in operator panel

    3 3 3

    2 2 2 2 2

    1 1 1 1 1 1 1 1

    Occurances- Aug-13 Occurances

    Machine name

  • 7/29/2019 iw29new aug-13 (1)

    7/15

    Machine name

  • 7/29/2019 iw29new aug-13 (1)

    8/15

  • 7/29/2019 iw29new aug-13 (1)

    9/15

  • 7/29/2019 iw29new aug-13 (1)

    10/15

    Repeated BD elimination

    S.No. M/C code Problem Cause

    1 SVM-403 HSRA line

    Hydraulic pressure in SVM-

    403 machine going down

    from 30kg to 20 kg

    Vane pump setting disturbed

  • 7/29/2019 iw29new aug-13 (1)

    11/15

    Action Done date Effectiveness

    Dismentelled thepump and set the

    ring and spring as

    per drawing of

    Pump

    28.08.2013Pressure set is on 35 kg still

    maintained and not coming down

  • 7/29/2019 iw29new aug-13 (1)

    12/15

    Preventive action

    Training manual to be made to set the pump if

    there is any variation in pressure due to pump

    setting distrubed

  • 7/29/2019 iw29new aug-13 (1)

    13/15

    1 Belt Inspection weekly

    2 Pulley Inspection weekly

    3 Operator panel inspection weekly

    4 Lub oil leakage inspection fortnightly

    5 Hydraulic oil leakage inspection fortnightly

    6 Coolant leakage from machine inspection fortnightly

    7 Mist collector cleaning monthly

    8 SRG- rotary runout on Shunk weekly

    9 Coolant entry in SRG rotary weekly

    10 Parralalism bolt length in roatry plate weekly

    11 Stabilser maintenance monthly

    12 Thru coolant rotary coupling inspection monthly

    13 Compressor service monthly

    14 R.O. service monthly

    15 Softner working / service monthly

    16

    17

    18

    19

    20

    Monthly Inspection Schedule

    Sr.No. Activity Planned Schedule

    Date

  • 7/29/2019 iw29new aug-13 (1)

    14/15

    Line SHIFT Month Date M/c Description

    Intake A August 1-Aug-13 8STN-403 Back chamfer motor power short

    Intake A August 1-Aug-13 8STN-403 Back chamfer motor not run.

    Intake A August 2-Aug-13 8STN-403 Back chamfer motor trip

    Intake A August 29-Aug-13 8STN-403 SOUND PROB,

    Intake B August 29-Aug-13 8STN-403 A AXIS O.V.C. ALARM

  • 7/29/2019 iw29new aug-13 (1)

    15/15

    Dept. Type Duration start time end time Duration

    107 M2 90 10:30 12:00 90

    107 M2 120 13:30 15:30 120

    107 M2 15 13:45 14:00 15

    107 M2 10:30 14:10 220

    107 M2 55 17:15 18:10 55