Iub Over IP Migration Ver2

40
Iub over IP Migration

description

a

Transcript of Iub Over IP Migration Ver2

Page 1: Iub Over IP Migration Ver2

Slide titleIn CAPITALS

50 pt

Slide subtitle 32 pt

Iub over IP Migration

Page 2: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-282

Iub Over IP Migration

Defining network topology and nodes interconnectivity

Install and configure ET-MFX boards in the nodes

Migration of Iub to IP

Test IP connectivity after the migration

Test cases using Iub over IP

Page 3: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-283

Defining network topology and nodes interconnectivity Layer 3 Topology, LMF STP

RBS17

RNC33OSS-RC

R

R1

R2

S1

S2

Traffic and Signaling

O&M Traffic

Page 4: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-284

Install and configure ET-MFX12 boards in the RNC The ET-MFX board is the key product to be installed in

the RNC in order to handle Iub traffic over IP For Installing the ET-MFX boards in the RNC confirm

that the following prerequisites are fulfilled

– ET-MFX12 boards are available

– RNC is Hardware R4 or higher

– The RNC has available slots for installing the new ET-MFX12 boards, Extension subrack preferred

– The RNC is running P6 software

Page 5: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-285

Install and configure ET-MFX12 boards in the RNC

– The appropriate cable kits and applicable ICF connections plates are available

– A Thin Client configured to run EMAS

– Java 1.4.2_8 or higher is installed on the Thin Client

– Mo and/or BCT configuration scripts are available and prepared according to network IP address plan

– OSS R5.3 up and running in case of BCT files are used

Page 6: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-286

RNC 3810 with IP

RNC model C in example

Iub

Iub: ET-MFX12– 7 port built in Ethernet switch– 1 SFP + 6 Electrical Eth. ports

Variant with 6 SFP and 1 Electrical ports available (ET-MFX13)

– Synch server

Page 7: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-287

Install and configure ET-MFX12 boards in the RNC Procedure to install ET-MFX boards in the RNC

• Open EMAS from OSS-RC, OSS network Explorer

Page 8: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-288

Install and configure ET-MFX12 boards in the RNC

Before plug in the ET-MFX board in the RNC, make sure that no objects are created below the Slot where you wish to install the board

Page 9: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-289

Install and configure ET-MFX12 boards in the RNC

Verify that Auto Configuration is activated

Page 10: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2810

Install and configure ET-MFX12 boards in the RNC

Before Installing the ET-MFX12 boards. The ET-MFX12 Software Allocation role must be assigned to the right slots,

Run Expand RNC Tool Part 1

Page 11: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2811

Install and configure ET-MFX12 boards in the RNC

Select for slot(s) appropriate Software Allocation Role

Page 12: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2812

Install and configure ET-MFX12 boards in the RNC

Go back to the MS (Main subrack) frame and insert the RNC UserId and Password in the blank field, then press Apply

Page 13: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2813

Install and configure ET-MFX12 boards in the RNC

Insert ET-MFX12 Board(s) and Cabling

Ethernet/IP Backhaul (port 6 for electric and port 7 for optical cable)

Redundancy Jumper from other ET-MFX (Port 1)

Page 14: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2814

Install and configure ET-MFX12 boards in the RNC

Run Expand RNC Tool Part 2 Insert the RNC UserId and Password in the blank field, then press Apply

Page 15: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2815

Install and configure ET-MFX12 boards in the RNC

ET-MFX12 board are installed

Page 16: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2816

Install and configure ET-MFX12 boards in the RNC

Check that every System Created Object is installed

IpAccessHostEtIpAccessHostGPB

IpSystem

IpInterface

InternalEthernetPort EthernetSwitch

ExchangeTerminalIp

IpAccessHostPool

EthernetSwitchPort

SwitchStp

SwitchPortStp

ManagedElement Equipment Subrack

PlugInUnit

Slot

TransportNetwork

Sctp

Red frame = System created

Page 17: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2817

Install and configure ET-MFX12 boards in the RNC

RSTP

Packet distributo

r

ET-MFX

Host

Ethernet switch

EthernetSwitchPort

systemPortuntaggedIngressPriorityuntaggedIngressVid

InternalEthernetPortdscpPbitMap

EthernetSwitch

SwitchPortStpRSTP

SwitchStp

ExchangeTerminalIp

Page 18: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2818

Install and configure ET-MFX12 boards in the RNC

If Objects are installed. Create a new Configuration Version

Page 19: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2819

Migration of Iub to IP

Configure using EMAS and mo scripts. This procedure will use five mo scripts to configure the User and Control plane as

well as the NTP Synchronization server in the RNC.

Page 20: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2820

User Plane transport – Configuration

Converter Packet distributor

ET-MFX

Host

Ethernet switch

IpAccessHostEt IpInterface

IpAccessHostEt

IpAccessHostEt

IpAccessHostPool

IurLink\IubLink

0..16

userPlaneTransportOptionuserPlaneIpResourceRef

RNC RBS

IpAccessHostEt

IubuserPlaneTransportOption

userPlaneIpResourceRef

Common defaultRouter0networkPrefixLengthvidvLan

ipAddressipAddress

ipAddress

Page 21: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2821

NTP Server – Configuration

NTP Server

Packet distributor

ET-MFX

Host

Ethernet switch

IpAccessHostEt IpInterfacentpServerMode

TUB

TU

Page 22: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2822

Control Plane transport – Configuration

IpAccessHostGpb IpInterface

IubLink

controlPlaneTransportOptionremoteCpIpAddress1sctpRef (ReadOnly)

IP Host(multi-homed)

MP

Packet distributor

ET-MFXEthernet switch

SCTP Host

Sctp

Packet distributor

ET-MFXEthernet switch

IpInterface

defaultRouter0networkPrefixLengthvidvLan

defaultRouter0networkPrefixLengthvidvLan

ipAddress1ipAddress2

NBAP-C NBAP-D

Page 23: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2823

RBS with IP

ET-MFX11– For Iub and O&M– IP/Ethernet interface with

optional Ethernet switch– 1 SFP + 6 Electrical Eth. ports– Synch client

3206 in example

Page 24: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2824

Install and configure ET-MFX11 boards in the RBS

Verify that Auto Configuration is activated

Page 25: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2825

Install and configure ET-MFX11 boards in the RBS

Install ET-MF11 Board in the RBS

Ethernet/IP Backhaul (port 6 for electric and port 7 for optical cable)

O&M from CBU (port 3)

O&M from ET-MFX port 2

Page 26: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2826

Install and configure ET-MFX11 boards in the RBS

Connect the Ethernet transport cable in the System port cable, the O&M cable must be connected from the CBU board to the ET-MFX11 board.

Add “jumper” cable for O&M from ET-MFX (System port 2) to CBU.

Page 27: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2827

Install and configure ET-MFX11 boards in the RBS

IpAccessHostEt

IpSyncRef

IpSystem

IpInterface

InternalEthernetPort EthernetSwitch

ExchangeTerminalIp

IpAccessHostGPB

EthernetSwitchPort

SwitchStp

SwitchPortStp

ManagedElement Equipment Subrack

PlugInUnit

Slot

TransportNetwork

Sctp

Red frame = System createdYellow frame = Initial configurationBlue frame = Site Basic (On-site)Green frame = Site Specific (ARW, BCT)

Check that System created Object is installed

Page 28: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2828

User Plane transport – Configuration

Converter Packet distributor

ET-MFX

Host

Ethernet switch

IpAccessHostEt IpInterface

IpAccessHostEt

IpAccessHostEt

IpAccessHostPool

IurLink\IubLink

0..16

userPlaneTransportOptionuserPlaneIpResourceRef

RNC RBS

IpAccessHostEt

IubuserPlaneTransportOption

userPlaneIpResourceRef

Common defaultRouter0networkPrefixLengthvidvLan

ipAddressipAddress

ipAddress

Page 29: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2829

Synchronization – Configuration (RBS)

NTP term. Packet distributor

ET-MFX

Host

Ethernet switch

CBU

TU

IpInterfacentpServerMode

IpSyncRefntpServerIpAddress

Synchronization

Page 30: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2830

Control Plane transport – Configuration (RBS)

IpAccessHostGpb

IpInterface

controlPlaneTransportOption

activeBearer (ReadOnly)sctpRef (ReadOnly)

Iub

NbapCommon

NbapDedicated

IP Host

Packet distributor

ET-MFXMPEthernet switch

SCTP Host

Sctp

activeBearer (ReadOnly)sctpRef (ReadOnly)

ipAddress1ipAddress2 defaultRouter0

networkPrefixLengthvidvLan

NBAP-C NBAP-D

Page 31: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2831

Install and configure ET-MFX11 boards in the RBS The procedure to configure the ET-MFX11 board in the

RBS will be done using the following steps:

1. Using EMAS Modify RBS Equipment Configuration for running a local xml script file to configure the Ethernet Ports.

2. Create User Plan objects.3. Create Control Plan objects.4. Add the NTP Synchronization server reference.5. Create a Configuration Version.

Steps 2 to 4 can be done with mo scripts and EMAS or BCT files using OSS.

Page 32: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2832

Test IP connectivity after the migration

RBS17

RNC33OSS-RC

R

R1

R2

S1

S2

Traffic and Signaling

O&M Traffic

RNC IP Addresses:

User Plane: 192.168.104.4

192.168.104.5

Control Plane: 192.168.104.6

192.168.104.7

192.168.104.8

192.168.104.9

192.168.104.10

192.168.104.11

RBS IP Addresses

User Plane 192.168.106.2

Control Plane 192.168.106.3

Page 33: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2833

Test IP connectivity after the migration RNC towards RBS

– To test RBS user plane and SNTP synchronization client use the ping() action of the IpAccessHostEt MO.

acc IpAccessHostEt ping 192.168.106.2

– To test RBS control plane, use the command ipac_ping on Central MP. Remember that the RNC control plane IP, must be the one handling the respective Iub link.

ipac_ping –z <RNC CP IP> -d <RBS CP IP> e.g. ipac_ping –z 192.168.104.6 –d 192.168.106.3

Page 34: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2834

Test IP connectivity after the migration RBS towards RNC

– To confirm the SNTP synchronization server check status of the attribute syncStatus in the IpSyncRef MO. The ipac_ipsyncref or nssinfo on MP will give a status of the synchronization.

– To test the RNC user plane IP address, use the ping() action of the IpAccessHostEt MO.

acc IpAccessHostEt ping 192.168.104.4

– To test the RNC control plane, use the ipac_ping command on MP. When testing the connectivity at the control plane level, the destination IP address must be the IP address of the MP that handles the Iub link of the node.

ipac_ping –z <RBS CP IP> -d <RNC CP IP> e.g. ipac_ping –z 192.168.106.3 –d 192.168.104.6

Page 35: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2835

Test IP connectivity after the migration

EMAS can be also used for UP ping tests

Page 36: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2836

Test IP connectivity after the migration

Add CP address and Execute

Page 37: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2837

Test cases using Iub over IP

Do test cases as described in Test Cases IP RAN Early Launch (LMF-08:000079 Uen)

Page 38: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2838

Troubleshooting

Common Problems– No IP Connectivity– No IP Sync Reference– Intermitente Sync Failure

TOOLS– RNC Pings (UP - action on IpAccessHostEt | CP - ipac_ping)– WireShark– Iperf

Page 39: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2839

References

IUB over IP Implementation (LMF-08:000077 Uen )

Hardware and Cabling Requisites (LMF-07:002148 Uen)

O&M of Iub on IP/Ethernet transport in UTRAN P6

IP Transport in WCDMA RAN P6 Presentation, FJW/SD Erik Jonsson

Page 40: Iub Over IP Migration Ver2

Top right corner for field-mark, customer or partner logotypes. See Best practice for example.

Slide title 40 pt

Slide subtitle 24 pt

Text 24 pt

Bullets level 2-520 pt

LMF-08:000078 Uen Rev PA8 Ericsson Internal Iub Over Ip Migration 2008-01-2840