    IuB

    Data Configuration

    Wireless Case and TrainingWRAN Training Team

  • 8/12/2019 IuB Data Configuration

    2/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2

    1-IuB Data Configuration Overview

    2-IuB NodeB configuration process using CME

    3-IuB RNC configuration process

  • 8/12/2019 IuB Data Configuration

    3/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3

    AbbreviationsCME Configuration Management Element

    WBBPa WCDMA Baseband Process unit Type A

    WRFU WCDMA Radio Filter Unit

    UBFA Universal BBU Fan Unit Type A

    UEIU Universal Environment Interface unit

    UELP Universal E1/T1 Lighting Protection unit

    UFLP Universal FE/GE Lighting Protection unitUPEU Universal Power and Environment Interface Unit

    UTRP Universal Transmission Processing Unit

    DCDU-01 Direct Current Distribution Unit-01

    EXT Extending

    MRRU Multi-carrier Remote radio unit

    CPRI Common Protocol Radio Interface

    NPSU NodeB Power Supply Unit

    NPMU NodeB Power Monitoring Unit

  • 8/12/2019 IuB Data Configuration

    4/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4

    1- IuB Data Configuration Overview

    NodeB initial data configuration

    Definition:

    NodeB initial configuration is the process of preparing and configuring the data

    after the NodeB hardware components are installed. The configuration is based

    on the NodeB hardware components, network planning, and data negotiationbetween the NodeB and other equipment. After the configuration, a data

    configuration file is generated.

  • 8/12/2019 IuB Data Configuration

    5/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5

    Data Configuration Overview

    Tool ---- WRAN CME:

    A tool for NodeB initial configuration, provides an integrated

    solution to RAN data configuration

    This tool can be used for initial configuration and data

    reconfiguration for the NodeB and the RNC

    The GUI-based CME provides the operating platform for RAN

    data configuration

    The forth generation NodeB require the CME V100R008 version

    Methods :

    manually adding a NodeB

    adding a NodeB through a template file

    adding a NodeB through a existing configuration file

  • 8/12/2019 IuB Data Configuration

    6/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6

    Data Configuration Overview

    2- IuB NodeB configuration process using CME

    Configuring

    NodeB

    Data

    Step1:

    Configuring Physical

    Equipment

    Step 2:

    Configuring TransportStep3:

    Configuring Local cell

    The NodeB data configuration script name is NodeBCfg.xml

  • 8/12/2019 IuB Data Configuration

    7/22HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7

    Procedure Configuring NodeB Physical Equipment

    Physical Equipment Configuration

    Create Logical and Physical NodeB

    Used for BTS3900&A Used for DBS3900

    Choose Macro NodeB Attribute

    Add UL baseband

    resource group Add

    NPMUAdd

    NEMU

    Add

    NPSU

    End

    Add UTRP

    Add UTRP1~9

    Add WMPT

    Add WBBP

    Add UPEA/UPEB B

    Add BBU board

    Add UEIU

    Add RF

    Chain/Ring

    Add WRFU

    Add MRRURHUB/PRRU

    Add DL baseband

    resource group

    Add

    UFAN

    220V

    Add BBU

    B

    Add RF

    Chain/Ring

    Add MRRU

    RHUB/PRRU

    APM30/100/200Add NPMU/NPSU

    /NCMU

    Antenna

    Device

  • 8/12/2019 IuB Data Configuration

    8/22

  • 8/12/2019 IuB Data Configuration

    9/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9

    DBS3900 board configuration

    Subrack

    number

    Subrack

    typeSlot number Board type MML Command

    0 BBU3900

    03 WBBPx/UTRP ADD BRD

    45 UTRP ADD BRD

    67 WMPT ADD BRD

    16 UBF ADD BRD

    1819 UPEA/UPEB/UEIU ADD BRD

    6 EXT 0 NEMU ADD BRD

    7 NPSU 0 NPMUSET

    PWRSYSCFG

    8 NCMU 0 NCMUSET

    PWRSYSCFG

    20~254 RRU 0MRRU/PRRU/RH

    UBADD RRU

    Configuring Physical Equipment

  • 8/12/2019 IuB Data Configuration

    10/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10

    Configuring Physical Equipment

    DBS3900 equipment plane

    Right-click the slot numbers, and configure related parameters based on prepared

    data so as to add board information of the BBU.

  • 8/12/2019 IuB Data Configuration

    11/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11

    The RF Configuration Rules of New NodeB

    The mechanism of the RF board is the chain and ring mechanism in V200R010.

    WRFU of BTS3900

    RRU of DBS3900

    The steps of configuration the RF board

    1.ADD SUBRACK to add RFU cabinet.

    2.ADD RRUCHAIN to add chain or ring.

    3.SET RRUCHAINBRKPOS to set the break pointoptional)

    4.ADD RRU to add WRFU/MRRU/PRRU

    5.RMV RRUCHAINBRKPOS to cancel the break point

    optional

    Right-click the RRU chain to configure the previous five steps in CME software.

  • 8/12/2019 IuB Data Configuration

    12/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12

    The Backup Mode of RF board

    MRRU only support the cold backup mode

    The backup mode should be configured in properties of the RRU chain/ring

    The hot backup ring can not support the upper layer cascading

    The RRUs are of the following types: MRRU, RHUB, PRRU, and WRFU

    The RRU Chain of the distributed NodeB supports the configuration of threeRRU types: MRRU, RHUB, and PRRU

    the RRU Chain of the macro NodeB supports the configuration of four RRU

    types: MRRU, RHUB, PRRU, and WRFU

  • 8/12/2019 IuB Data Configuration

    13/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13

    TransportConfiguration

    Create NodeB

    Add UTRP

    Add FractionalATM

    Add UNI LINKAdd IMA Group

    Add WMPT

    Add IMA Link

    Add Treelink PVCAdd NCP/CCP/IPoA DeviceAdd ALCAP Add CES

    Add AAL2 Path

    Add Time SlotAcross

    Add STM-1 Link

    End

    Configuring Transport over ATM

    Configuring Transport

  • 8/12/2019 IuB Data Configuration

    14/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14

    Configuring Transport over ATM

    Adding NCP

    Adding CCP

    Adding ALCAP

    Adding AAL2path

    Adding Tree link PVC

    Adding OMCH

  • 8/12/2019 IuB Data Configuration

    15/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15

    Configuring Transport over IP

    TransportConfiguration

    Configure the IP Route

    Configure the PPP

    End

    Configure the MLPPPConfigure the timeslot

    Cross channelConfigure the Dev IP

    Configure the Qos Optional

    Configure the SCTP

    Configure the IPCP

    Configure the OM

    Configure the IP Path

  • 8/12/2019 IuB Data Configuration

    16/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16

    Configuring Transport over IP

    Configure the PPP, MP, and Ethernet IP

    In a single transport mode, configure one type of transport links.

    In hybrid transport mode, configure E1 and FE transport links.

    For E1 links, configure PPP or MP

    For FE links, configure PPPoE or Ethernet IP

    IP networkNodeB RNC

    PDH/SDH

    IP hybrid transmission

  • 8/12/2019 IuB Data Configuration

    17/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17

    Configuring Local Cell

    Procedure of Local Cell Configuration

    Add

    Site

    Add

    Sector

    Add

    Local

    Cell

    Local

    cell

  • 8/12/2019 IuB Data Configuration

    18/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18

    Configuring Local Cell Adding Site

    Adding a site to the NodeB

    Note

    A site number within one

    NodeB must be unique.

    Adding Sector

    Adding a sector to the NodeB

    Note

    A sector number must be unique within one NodeB

    Configuring a sector is mainly configuring the corresponding

    antenna and feeder system

  • 8/12/2019 IuB Data Configuration

    19/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19

    Configuring Local Cell

    Adding Local Cell

    Adding a local cell to the NodeB

    Note

    Local Cell ID must be unique within thesame NodeB

    Negotiated with the peer end RNC

    Local Cell ID

    Uplink Frequency Downlink Frequency

  • 8/12/2019 IuB Data Configuration

    20/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20

    IuB RNC configuration process over ATM

    Configuring the Physical Layer

    Configuring the ATM Traffic Resources

    Configuring the Control Plane of the Iub Interface

    Configuring the Mapping Between Service Types and TransmissionResources

    Configuring the User Plane of the Iub Interface

    Configuring the OM Channel over the Iub Interface

    http://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-96-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-100-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-101-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-102-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-102-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-103-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-104-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-104-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-103-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-102-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-102-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-101-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-100-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-96-u.html
  • 8/12/2019 IuB Data Configuration

    21/22

    HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21

    IuB RNC configuration process over IP

    Configuring the Physical Layer and Data Link Layer (over IP)

    Configuring the Control Plane for the Iub Interface (over IP)

    Configuring the Mapping Between Service Types and Transmission

    Resources

    Configuring the User Plane over the Iub Interface (over IP)

    Configuring an OM Channel over Iub Interface (over IP)

    http://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-106-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-111-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-112-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-112-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-113-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-114-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-114-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-113-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-112-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-112-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-111-u.htmlhttp://localhost:7890/pages/31184420/10/31184420/10/resources/mbsc/m-bsc-initial-configuration-guide/mbsc-8-106-u.html