ITAINNOVA TA: Scientific & Administrative issuesElectromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)
Dr. Fernando Arteche
Advanced European Infrastructures for Detectors at AcceleratorsAIDA 2020 - kick-off Meeting
3-5 June 2015, CERN
![Page 2: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/2.jpg)
OUTLINE
• 1. Introduction• 2.Scientific issues
–Activities–Equipment–Test goals
• 3. Administrative issues–Reimbursement policy
• 4. First EMC TA.2 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 3: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/3.jpg)
• The Instituto Tecnológico de Aragón (ITAINNOVA) is a non-profit public Technology Centre located in Zaragoza (Spain)– Founded 1985 – Facilities 15000 m2
1. Introduction
3 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
• ITAINNOVA activities are focused on :– Applied research– Technical development– Technical services
• Main R&D lines – Material engineering– Industrial systems– Logistics– Multimedia Technologies
• The number of ITA employees is 220.
![Page 4: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/4.jpg)
1. Introduction • One group of ITAINNOVA focused its efforts on electrical
engineering aspects for complex systems– Electromagnetic Compatibility issues– Electrical power systems designs
• Since 2009 this group has been participating in high energy physics (HEP) projects for future colliders– R&D on EMC ( grounding & shielding issues)– R&D on new powering schemes
• It has been involved in :– CMS upgrade – HL-LHC at CERN– Belle II – SuperB at KEK– ILD - ILC
• Since 2012 ITAINNOVA became associate member of CMS4 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 5: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/5.jpg)
2. Scientific issues• ITAINNOVA - EMC facilities allow to perform
Electromagnetic Compatibility Test .– Non–standard test (Specially focused on HEP)– Standard ( According to European Directive 2004/108/EC)
• These tests may be used to define in any electronic device installed in HEP experiment:– EM noise emission level (noise emission test)
• Conducted• Radiated
– EM noise immunity level (noise injection test)• RF conducted and radiated noise• Transients test
5 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 6: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/6.jpg)
2.1 Scientific issues: Activities• Conducted immunity test – SVD system for Belle II
• Radiated emission test – Cable radiation of SVD system for Belle II 6 / 19
Big perturbing signal to background noise
ratio ( x 100 times)
“Electromagnetic clean room”
( below 1 uA)
![Page 7: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/7.jpg)
• PS Transient test – SVD for Belle II
• LV regulator response to voltage dips – HCAL system for CMS
Voltage dips & variation of Power mains
2.1 Scientific issues: Activities
7 / 19
Voltage dips & variation of LV lines
![Page 8: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/8.jpg)
• It can be used to test small components or units……
2.1 Scientific issues: Activities
8 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
FEE unit (readout chips + sensor)
FEE boards - hybrids
Big power supplies
Small DC-DC
Hybrids
![Page 9: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/9.jpg)
……….and mid-scale prototypes can be tested too.
2.1 Scientific issues: Activities
9 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
Belle II –SVD EMC test campaign
![Page 10: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/10.jpg)
• The EMC equipment at ITAINNOVA is :– 2 X Semi-anechoic chamber– Faraday cage– Equipment to perform transient tests– Electrostatic discharge (ESD) up to 30 kV– Current probes from 20 Hz up to 400 MHz. – Antennas from DC up to 18 GHz. – RF Generators up to 20 GHz & Amplifiers
up to 6 GHz.– Spectrum Analyzers and EMI Receivers
from 20 Hz up to 28 GHz – 2 channel oscilloscopes (2 Gs/s).– Shielding effectiveness measurement
system (20 MHz – 1 GHz).
2.2 Scientific issues: Equipment
10 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 11: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/11.jpg)
• What ´s the purpose of these tests ? • What is the information that can be obtained once the
data is processed?....• These tests are very good for:
– Grounding topologies evaluation• Diagnosis
– FEE designs• Detection of sensitive areas • FEE frequency response to noise
– Noise distributions – EM mapping• Conducted or radiated
– Filter designs– Noise emission specification from PS
2.3 Scientific issues: Test goals
11 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 12: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/12.jpg)
0 5 10 15 20 25 300
5
10
15
20
25
30
Channel number
[RM
S C
ounts
]
Reference8 MHz• Diagnosis & Sensitive areas
– CMS- HCAL – Ground connection photodiodes-Board
– CMS- Pre-shower - Ground connections between paths
– Belle II – SVD - APV25 signature
CMS-HCAL
CMS-Pre-shower
2.3 Scientific issues: Test goals
12 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
BelleII-SVD
![Page 13: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/13.jpg)
• Conducted noise mapping : Filtering designs
Total noise
PS noise emissions FEE noise emissions
2.3 Scientific issues: Test goals
13 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
Belle II –SVD
![Page 14: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/14.jpg)
• To quantify the sensitivity of the FEE to noise currents– Ensuring compatibilities among sub-systems– It helps to evaluate and quantify designs
14 de 54
105
106
107
108
10-5
10-4
10-3
10-2
10-1
100
101
TF
[Cou
nts
/ mA
]
Frequency [Hz]
HCAL
Tracker - PK
Tracker -DECPres-HG
Pres -LG
2.3 Scientific issues: Test goals
14 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 15: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/15.jpg)
3. Administrative issues• ITA offers the possibility to perform any EMC test for a period
of 5 weeks per year.• Access duration:
– Standard access (components) : Less than 1 week– Extended access (large systems) 2 - 3 weeks.
• Users are expected to request the access a few months in advance and to have a technical discussion about its specific needs prior to the access (Follow the official TA procedure)• On site review is very recommended - 1 day meeting !!!!
• Users are expected to be present at ITA during the tests while ITA engineers will operate the testing equipment of the facility – It is possible to ask for a remote access – It is mainly focused on
EMC directive tests or PS noise emissions tests.
15 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 16: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/16.jpg)
• After the test campaign ITAINNOVA will provide:– A report with the test descriptions and test log– A ftp sever will be created to transfer the data
• Spectrum profiles• Log files and pictures
– The analysis of the data is excluded, nevertheless some help in order to analyze the data as well as support to design the test campaign will be provided.
• The cost of shipping equipment under test will NOT be covered.
3. Administrative issues
16 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 17: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/17.jpg)
• Travel expenses for one person to get access to the facility will be covered by AIDA2020 for each project approved.
• Only economy class air travel and second class train travel will be reimbursed.
• Car travel will be reimbursed at 0.25 EUR/kilometer up to a maximum of 150 EUR per complete trip.
• Hotel will be booked and paid directly by ITAINNOVA. User name, passport number as well as arrival and departure dates should be provided in advance.
• A per diem allowance of 36 EUR/day for each working day will be paid.
• A ticket for lunches will be provided by ITAINNOVA for each working day.
3.1 Administrative issues: Reimbursement policy
17 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 18: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/18.jpg)
• Official taxes will be deducted from the reimbursement based on Spanish regulations
• All receipts and tickets in original form including boarding cards must be enclosed and returned with the claim.
• Claims must be made within two months after travel completion.
• The claim form must be filled in and returned to the ITAINNOVA secretary ([email protected])
• The time frame for reimbursement is a two-month period.
3.1 Administrative issues: Reimbursement policy
18 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.
![Page 19: ITAINNOVA TA: Scientific & Administrative issues Electromagnetic Compatibility Facility for electronics noise and grounding diagnostics (WP12 – Task 12.2)](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649dc75503460f94abbf73/html5/thumbnails/19.jpg)
• HEPHY institute (from Vienna) has requested an access– Extended access - Full EMC characterization of SVD
prototype for Belle II (2 weeks) – Visitors – It is completed– Standard access (3 days) – Conducted noise emissions of DC-
DC converters – Remote access – End of June• We spent one day in Vienna designing the test campaign
– Very useful (a month in advance)• The test campaign was very useful - It finished last Monday
– 70 GB of data – More than 500 measurements– 10-12 working hours per day (for two weeks)
• This is the first time that a HEP detector has been characterized in a semi-anechoic chamber.
4. First EMC TA access
19 / 19This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 654168.