Is this still an Interior Lining? -...
Transcript of Is this still an Interior Lining? -...
Celebrating 40 years of taking care of Missouri’s natural resources.
Is this still an
Interior Lining?
Heather Peters
Missouri Department of Natural Resources
Celebrating 40 years of taking care of Missouri’s natural resources.
New Federal Language 280.21
• Installed in accordance with 280.33
• Inspected on 10/5 year interval
If it is no longer performing in accordance
with original design specifications and
cannot be repaired in accordance with a
code of practice developed by a nationally
recognized association or independent
testing laboratory, then the lined tank must
be permanently closed…
Celebrating 40 years of taking care of Missouri’s natural resources.
But my lining isn’t for upgrades!
• Do you require inspection/ maintenance
for other linings?
• Compatibility?
• Repair?
• Secondary Containment?
• Do those regulations require I & M?
Celebrating 40 years of taking care of Missouri’s natural resources.
Celebrating 40 years of taking care of Missouri’s natural resources.
Interior Lining- Standards • American Petroleum Institute (API) RP1631
• National Leak Prevention Asso (NLPA) 631
• American Society for Testing and Materials
(ASTM) G158? – Purpose is for cathodic protection, not lining
• Underwriters Laboratory (UL)1856? – Construction NOT Inspection
Celebrating 40 years of taking care of Missouri’s natural resources.
API 1631 (Periodic Inspections)
• “Qualified person”
• Thickness/ Hardness checked
• Holiday detector for air pockets, leaks,
pinholes
• Steel tank integrity test required (must
have at least 75% original steel
thickness)
Celebrating 40 years of taking care of Missouri’s natural resources.
API 1631 (Periodic Inspections)
• Peeling
• Blistering
• Wrinkled
surface
• Defects repaired to manufacturer specs
Celebrating 40 years of taking care of Missouri’s natural resources.
Celebrating 40 years of taking care of Missouri’s natural resources.
NLPA 631 B Lining Inspections
• Certify employees…are knowledgeable
• Special inspector or qualified person
• Lining shall be tested:
– Signs of peeling, blistering, surface wrinkling
– Thickness/ Hardness/ Holiday testing
• Steel Integrity testing requirements (must
have at least 75%/85% original steel
thickness)
Celebrating 40 years of taking care of Missouri’s natural resources.
API 1631 and NFPA 631
• Both allow linings to be repaired
• Both require passing (75%) integrity
assessment of the steel tank
• Both have detailed breakdown of the
number and location of steel tank
measurements
• Does not allow mean-time-to-corrosion in
lieu of steel shell evaluation
Celebrating 40 years of taking care of Missouri’s natural resources.
Celebrating 40 years of taking care of Missouri’s natural resources.
Video Inspections????
• Ken Wilcox Associates Recommended
Practice for Inspecting Buried Lined Steel
Tanks Using a Video Camera
• Defines certified/qualified persons
• Signs of separation, delamination,
blistering, peeling, holidays
• Thickness/ Hardness test (minimum 5 at
each opening)
• Inspection only
Celebrating 40 years of taking care of Missouri’s natural resources.
Certifications?
• Confined Entry
• NACE International
– Coatings Inspector
• International Code Council (ICC)
– UST Installation/Retrofitting
• Society for Protective Coatings (SSPC)
• State specific?
Celebrating 40 years of taking care of Missouri’s natural resources.
UL1856- The New Retrofit Standard
1. Lining: single-walled
2. Upgrade: double-walled
– “Co-structural”: requires original “host” tank integrity
3. Self-structural: double-walled
– Does NOT require original “host” tank integrity
– Does NOT require steel tank to pass integrity test
Celebrating 40 years of taking care of Missouri’s natural resources.
Lining (UL1856)
• Single-walled
• Lining flush
against steel
• Steel
assessment in
standards
Celebrating 40 years of taking care of Missouri’s natural resources.
• Two walls of
the lining
• First layer
against steel
• Interstitial
space
• Steel integrity
required
Upgrade, double-walled
Celebrating 40 years of taking care of Missouri’s natural resources.
Self-structural
• Two lining
layers
• First layer
against steel
• Interstitial
space
• Steel integrity
NOT required
Celebrating 40 years of taking care of Missouri’s natural resources.
Inspections
Video/ Manned Inspection
• Every 5 years
• Assesses steel
• Assesses lining condition
• Failure only detected at
inspection (once in 5
years)
Interstitial Monitoring
• Continuous (NWGLDE def)
• Checks every day for 5
years
• Interstitial check catch
interior wall failure from
portion that contains fuel
• Exterior fail may be seen
• Does not assess condition
or approaching problems
• Detects failure immediately
?
Celebrating 40 years of taking care of Missouri’s natural resources.
Inspections and Monitoring Single-wall Lining
Video inspection
Entry inspection
5 year test
(only option)
Steel integrity
Double-wall Upgrade
Video inspection
(inside layer)
Entry inspection
(inside layer)
5 year test
Interstitial testing
? Steel Integrity
Can I even inspect it?
Self-structural
Video inspection
(inside layer)
Entry inspection
(inside layer)
5 year test
Interstitial testing
? Steel Integrity
Can I inspect it?
If steel doesn’t
matter, can I
exclude it?
Celebrating 40 years of taking care of Missouri’s natural resources.
Can I even inspection it?
• Lining: Yes, traditional inspection
• Double-walled co-structural:
– Video? Interstitial?
– If you allow G158 for steel assessment?
NOT INTENDED PURPOSE
• Self-structural:
– Inner layer only (if waive steel assessment)?
– If you allow interstitial? Video?
Celebrating 40 years of taking care of Missouri’s natural resources.
Steel Integrity Assessment
Can I do it? Must I do it?
Lining (single-walled) YES YES
Double-walled lining NO?? YES
Self-structural NO?? NO?? YES?
Celebrating 40 years of taking care of Missouri’s natural resources.
Is it eligible for repair?
Lining: Steel passes
Double-walled, co-structural:
If you allow mean-time-to-corrosion?
No repairs?
Self-structural: Manufacturer repair only? No
repairs?
Is a re-lining a repair? If okay to patch, but
prefer to re-line….
Patch?
But not
Re-line?
⤴
⤶ ⤶
Celebrating 40 years of taking care of Missouri’s natural resources.
Rules, Installs, Inspections
• Regulation: Inspect to industry standard
• Inspection Standard: Can repair IF steel
passes
• UL1856 Installation Standard: Steel is
irrelevant for Self-Structural
• What do I do?
Celebrating 40 years of taking care of Missouri’s natural resources.
Your Regs - Your SPA
• Opening Regulations
• Understand the standards
• What works for your state?
• Can you prove it is equitable?
• Talk to EPA about your SPA!
Celebrating 40 years of taking care of Missouri’s natural resources.
Questions- Now or End of the