IS H 0 · 2019. 9. 6. · IS-144EH H 2 O IS-144GH H 2 O IS-196EH H 2 O IS-196GH H 2 O Machine Size...
Transcript of IS H 0 · 2019. 9. 6. · IS-144EH H 2 O IS-144GH H 2 O IS-196EH H 2 O IS-196GH H 2 O Machine Size...
-
L E O N A R D A U T O M A T I C S , I N C .“our reputation is stainless”
SteamleSS Garment tunnel FiniSher
100% Steamless!
IS H20
-
Leonard Automatics is proud to feature the PLC Interface Control Center on our IS Series tunnel finishers. The touch screen allows for intuitive and straightforward access to all tunnel operational controls. Features include automated troubleshooting, mainte-nance schedules, alarm logs, PM schedule, runtime history and much more. Total tunnel control is now at your fingertips.
The lint filters on the IS Series are accessible from outside the tunnel so that important filter maintenance can be performed easily without shutting down the tunnel. The filter screens are made with stainless steel mesh to help remove lint from the air flow.
Easy Filtration
PLC Control System
No steam means no boiler, and no boiler means elimnating boiler piping, maintenance, inspections and other related expenses. This is perfect for new facilities that do not wish to install a boiler, or ex-isting plants that want to remove their boiler from their operational process. For whatever reason you decide, the IS H2O will remove your boiler issues and expenses. Saves you therms and water consumption.
No Boiler Needed
-
The finishing of a garment starts in the conditioning chamber. The design of our conditioning section creates a higher veloc-ity of atomized water droplets that carries more energy and achieves proper finishing temperature faster. The S-turn design exposes each side of the garment to direct mist spray, and then fully surrounds the garment in the atmosphere of atomized water droplets.
S-Turn Technology
Instead of steam to finish garments, the IS H2O mixes hot water with heated air to create a fine atomized mist that is sprayed onto your product. This creates an atmosphere of atomized water droplets that preconditions the garments with high humidity and prepares them for final finishing in the heat section of the finisher. Hot air is directed into the conditioning chamber. This combination produces high quality finishing with less utility consumption.
Patented Atomized Mist
The IS H2O directs the flow of the atomized mist with a series of directional nozzles, spraying the atomized mist in just the right position for the garments. These nozzles control exact-ly how and where the atmosphere of atomized water droplets is formed, instead of simply spraying the mixture in a random cloud onto the garments. This means less wasteful excess and more accurate production for your garments.
Accurate Spray
-
5894 Balsom Ridge Rd. / PO Box 501 Denver, NC 28037 ph: 704-483-9316 / fx: 704-483-4538
[email protected] - http://leonardautomatics.com
Technical SpecificaTionS
The product may be covered by one or more of the following patents: Patent No: 7,845,037; 6,862,744; 6,910,291; 7,845,197;6,311,526. Futher patents may be pending. The color stainless steel is a registered trademark of Leonard Automatics, Inc.
IS-96EH H2O
IS-96GH H2O
IS-144EH H2O
IS-144GH H2O
IS-196EH H2O
IS-196GH H2O
Machine SizeLength (in/mm) 132 / 3,353 132 / 3,353 179 / 4,547 179 / 4,547 225 / 5,715 225 / 5,715
Width (in/mm) 60 / 1,524 60 / 1,524 60 / 1,524 60 / 1,524 60 / 1,524 60 / 1,524
Height (in/mm) 104 / 2,642 104 / 2,642 104 / 2,642 104 / 2,642 104 / 2,642 104 / 2,642
Weight (lbs/kg) 2,900 / 1,318 2,900 / 1,318 3,500 / 1,590 3,500 / 1,590 4,000 / 1,818 4,000 / 1,818
Electrical ServiceStandard Voltage 230 - 460v / 3ph / 60hz
Full Load Amps 100 / 51 25 / 14 173 / 88 37 / 20 234 / 118 46 / 24
Water RequirementsAverage Usage (gal/hr / l/hr) 24 / 91 24 / 91 27 / 102 27 / 102 30 / 113 30 / 113
Typical Water Pressure (psi/bar)
15 / 1 15 / 1 15 / 1 15 / 1 15 / 1 15 / 1
Water Connection (in/mm) 3/4 / 20 3/4 / 20 3/4 / 20 3/4 / 20 3/4 / 20 3/4 / 20
Drain Connection (in/mm) 1 / 25 1 / 25 1 / 25 1 / 25 1 / 25 1 / 25
Gas RequirementsOperating Pressure (w.c/mbar)
n/a 8.7 / 22 n/a 8.7 / 22 n/a 8.7 / 22
Burner Rating (btu/hr / kw) n/a 1,000,000 / 293
n/a 1,000,000 / 293
n/a 1,000,000 / 293
Average Usage (btu/hr / kw) n/a 165,000 / 48 n/a 245,000 / 72 n/a 325,000 / 95
Ventilation RequirementsExhaust Duct Size (in/mm) 12 / 305 12 / 305 12 / 305 12 / 305 12 / 305 12 / 305
Air RequirementsAverage Usage (scfm / l/hr) 22 / 37,375 22 / 37,375 25 / 42,475 25 / 42,475 28 / 47,570 28 / 47,570
Typical Air Pressure (psi/bar) 20 / 1.3 20 / 1.3 20 / 1.3 20 / 1.3 20 / 1.3 20 / 1.3
Air Connection (NPT) 1/2 1/2 1/2 1/2 1/2 1/2
*Please consult layout drawings for detailed dimensions including conveyor, control panels and utility connections. Specifications subject to change without notice. Manufactured in the U.S.A.Updated: 09/062019