IS 15500-1 to 8 (2004): Deepwell handpumps components and ...
Transcript of IS 15500-1 to 8 (2004): Deepwell handpumps components and ...
Disclosure to Promote the Right To Information
Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public.
इंटरनेट मानक
“!ान $ एक न' भारत का +नम-ण”Satyanarayan Gangaram Pitroda
“Invent a New India Using Knowledge”
“प0रा1 को छोड न' 5 तरफ”Jawaharlal Nehru
“Step Out From the Old to the New”
“जान1 का अ+धकार, जी1 का अ+धकार”Mazdoor Kisan Shakti Sangathan
“The Right to Information, The Right to Live”
“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता है”Bhartṛhari—Nītiśatakam
“Knowledge is such a treasure which cannot be stolen”
“Invent a New India Using Knowledge”
है”ह”ह
IS 15500-1 to 8 (2004): Deepwell handpumps components andspecial tools (amalgamation of IS 9301, 13056, 13287,14101, 14102, 14103, 14104, 141O5 and 14107) [MED 27:Handpumps]
IS 15500 (Parts 1 to 8) :2004
(Amalgamating IS 9301:1990,IS 13056:1991, IS 13287:1992,IS 14101 :1994, IS 14102:1994,Is 14103:1994, Is 14104:1994.
WwfkTm IS 14405: 1994 and IS f4107: 1999j
WR-1-i$* # FI*IQIhl-awi=ll+,qa+ha@wkfwm?m-mR
Indian Standard
DEEPWELL HANDPUMPS, COMPONENTS ANDSPECIAL TOOLS — SPECIFICATION
ICS 23.080
0 BIS 2004
BUREAU OF INDIAN STANDARDSMANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG
NEW DELHI 110002
Dg~e~ber 2004 Price Group 20
..
(Reaffirmed - 2010)
IS 15500 (Parts 1 to 8): 2004
Handpumps Sectional Committee, ME 27
FOREWORD
This Indian Standard (Parts 1to 8) was adopted by the Bureau of Indian Standards, after the draft finalized by theHandpumps Sectional Committee had been approved by the Mechanical Engineering Division Council.
The need for deepwell handpumps of proven design to ensure interchangeability of components, having a longworking life and requiring minimum possible maintenance, had resulted in initiation of work to bring out astandard on the subject. As a result of the combined efforts made in this direction by various voluntaryorganizations, government agencies and reputed manufacturers as well as by UNICEF, a standard on deepwellhandpumps IS 9301 ‘Deepwell handpums — Specification’ was first issued in 1979. This type of deepwellhandpump is also popularly known as India Mark II handpump.
The first revision of IS 9301which was issued in 1982 was taken up in order to bring the standard in line with thethen manufacturing practices. A number of modifications were incorporated in the first revision, of which thefollowing were important:
a) The requirements of galvanizing was incorporated so that the pumps were tlee of rust for longer periods.
b) The ‘performance test’ given in the 1979 version was designated as the ‘type test’ and a new clause on‘routine test’ was included.
The second revision of IS 9301 was brought out in 1984 in order to bring the standard in line with the techniquesthen prevalent for the manufacture of deepwell handpumps. The following were some of the important changesmade in the second revision:
a)
b)
c)
d)
e)
o
g)
Tolerances on some of the dimensions had been changed, and specified on the basis of IS 919 (Rut 1): 1963‘Recommendations for limits and fits for engineering: Part 1 General engineering @rst revision)’.
Stainless steel had been specified as the material for manufacturing handle axle.
Solid triangular gusset at the top and bottom of the handle bracket were provided.
Connecting rods and plunger rod had been provided with hexagonal couplers in place of locknuts.
40 mm tank spout had been specified in place of 32 mm one in order that the tank is immediately clearedof the water and there is no undue splash.
Rear two stand legs at 80° had been specified in place of 120° in order to increase the stability of thepump.
Painting had been deleted as an anti-corrosive treatment for steel components.
The third revision of IS 9301 was brought out in 1990 to bring the standard in fine with the then prevailingmanufacturing practices. The following changes were made in the third revision: “
a)
b)
c)
d)
e)
9
g)h)
j)
k)
m)
Stainless steel plunger rod and connecting rods incorporated.
Relief groove for handle axle specified.
Telescopic stand assembly included.
Stand assembly modified by providing spikes.
Design of reducer cap and cylinder body modified to prevent slippage.
Upper valve modified in two parts for eliminating failure due to unscrewing of upper valve seat retainer.
Welding of stainless steel components specified.
Critical dimensions, in the figures, identified for inspection purposes.
Nitrile cup washers had been introduced to improve life of the pump. However, leather cup washers wasintended to be phased out in two years time.
Bearing housing had been modified for minimizing distortion due to welding.
Third plate had been introduced for easy maintenance.
i
IS 15500 (Parts 1 to 8): 2004
n) Type test had been deleted.
p) Stroke length had been increased.
q) Discharge requirement increased from 12.0 litre to 15.0 litre during discharge test.
r) Height of water tank increased from 129 mm to 154 mm.
Since the development of deepwell handpump, considerable progress has been made in its refinement. Efforts ofdifferent organizations and individuals including UNICEF, UNDP/World Bank Water and Sanitation Programmecontributed to design improvement, increased reliability and simplified maintenance.
The outcome of these developmental efforts was the emergence of a handpump designated VLOM — Village -Level Operation and Maintenance deepwell handpumps with open top cylinder. Design of this handpump issuch that the most common repair can be done by local mechanics. Modifications incorporated in this pumpsimplify maintenance procedure and reduce maintenance cost. The basic difference of this pump with deepwellhandpump (IS 9301) is that this pump has open top cylinder which facilitates pulling out of plunger assemblyand check valve assembly from the cylinder without pulling out the riser main and the cylinder.
This type of pump is popularly known as India Mark 111deepwell handpump and the relevant Indian StandardIS 13056 ‘Deepwell handpumps (VLOM) — Specification’ was issued in 1991,
The initial additional investment and installation depth limitation had beqn identified as main constraints inadoption of VLOM pumps. Moreover increased static load of riser main and weight of water column alsoresulted in observation of shearing of riser pipe near the riser pipe holder in few cases. As a result, a smaller sizecylinder (50 mm) was developed to overcome such problems experienced in 65 mm cylinder. Afier successfidtrials of 50 mm cylinder for over 5 years, these were ultimately included in VLOM pump specification(IS 13056). The major advantages over 65 mm cylinder were the lower capital cost, reduced static load andweight of water column to support and ease in installation and maintenance.
As in some of the states, the static water level had gone below 40 m, the existing deepwell handpumps (IS 9301)were difficult to operate and therefore it was felt necessary to design a separate pump for such purposes. Theobjective set out for the development of the extra deepwell handpumps were:
a) to design a system, which allows the use and interchangeability of most of the components with theexisting deepwell handpumps (IS 9301), and
b) to keep operational efforts within reasonable limits.
This led to the emergence of India Mark H extra deepwell handpump and the relevant Indian Standard IS 13287was issued in 1992.
After publication of these handpump standards, based on the experience gained during manufacture, inspection,installation and their maintenance, six amendments were issued to India Mark 11handpump — Specification[1S 9301:1990 (third revision)]. Similarly 6 amendments were issued to VLOM pump — Specification(1S 13056: 1991) and 4 amendments were issued in Extra deepwell handpump — Specification (IS 13287: 1992),to keep abreast with the technological changes.
Over the years, demand had been generated to prepare a comprehensive document to cover all the three types ofhandpwnps for lifling water from deep set bore wells, water depth ranging from.,20m to 90 m. Further the needwas also felt to incorporate the requirements of components and special tools used in repair/maintenance of thesepumps to enable the users/purchasers to procure components as per this standard to ensure quality andinterchangeability. As a result, this Indian Standard has been formulated amalgamating following Indian Standards:
1S No. Title
9301:1990 Deepwell handpumps — Specification (third revision)13056:1991 Deepwell handpumps (VLOM) — Specification13287:1992 Extra deepwell handpumps — Specification14101:1994 Deepwell handpumps — Components — Cast iron — Specification14102:1994 Deepwell handpumps — Components — Leaded tin bronze — Specification14103:1994 Deepwell handpumps — Components — Mild steel — Specification14104:1994 Deepwell handpumps — Components — Nitrile rubber — Specification14105:1994 Deepwell handpumps — Components — Stainless steel — Specification14107:1999 Special tools for deepwell handpumps — Specification
ii
IS 15500 (Parts 1 to 8) :2004
All the amendments issued so far in the above specifications have been reviewed and incorporated whereverrequired in this standard.
On publication of this standard, the above Indian Standards would be withdrawn.
The formulation of amalgamated standard entailed the review of identification and packaging of handpumpcomponents covered in 1S 12732: 1989 ‘Nomenclature, identification and packaging of components for deepwellhandpumps’. It was felt that the packaging requirements should also be part of this amalgamated standard.Hence accordingly packaging requirements have also been included in this amalgamated standard. On publicationof this standard, IS 12732 would also be withdrawn.
It is expected that publication of the amalgamated document would facilitate all the concerned organizationsinvolved in development, manufacture, inspection, installation and maintenance activities, ultimately improvingthe availability of safe drinking water to communities.
For the purpose of deciding whether a particular requirement of this standard is complied with, the final valueobserved or calculated, expressing the resu It of a test or analysis shall be rounded off in accordance withIS 2:1960 ‘Rules for rounding off numerical values (revised)’. The number of significant places retained in therounded off value should be same as that of the specified value in this standard.
...111
IS 15500 (Parts 1 to 8) :2004
CONTENTS
Part 1 General
Part 2 Handpumps
Part 3 Handpump Sub-Assemblies
Part 4 Steel Components
Part 5 Cast Iron Components
Part 6 Brass/Bronze Components
Part 7 Rubber Components
Part 8 Special Tools
Annex A List of Referred Indian Standards
Annex B Standard Components
Annex C Recommended Packaging Procedure
Annex D List of Tools in a Set of Special Tools for Installationandlor Maintenance
Page
1
8
13
26
50
57
66
72
112
114
115
119
iv
.
AMENDMENT NO. 3 JUNE 2012 TO
IS 15500 (PARTS 1 TO 8) : 2004 DEEPWELL HANDPUMPS, COMPONENTS AND SPECIAL TOOLS — SPECIFICATION
(Page 1, Part 1, clause 1.3, tenth line) — Substitute ‘Brass/bronze or stainless steel cast components’ for ‘Brass/bronze components’. (Page 3, Part 1, clause 5.2.2) — Insert the following new clause after 5.2.2: ‘5.2.3 Components covered in Part 6 (Fig. 6.2 to Fig. 6.16) of the specification may be manufactured from stainless steel casting. The material of steel casting shall meet the requirements of IS 3444 : 1989 Grade 1 for Chemical and Mechanical properties.’ (Page 57, Part 6, clause 1.1, second line) — Add ‘or stainless steel cast’ after ‘bronze’. (Page 57, Part 6, Title, fourth line) — Substitute ‘BRASS/BRONZE OR STAINLESS STEEL CAST COMPONENTS’ for ‘BRASS/BRONZE COMPONENTS’. [Page 62, Part 6, Fig. 6.11 (see also Amendment No. 1)] — Substitute ‘ 0
–0.516 ’ for ‘ 0–0.317 ’.
(Page 66, Part 7, clause 2.1, third line) — Substitute ‘7.16’ for ‘7.15’.
1
Amend No. 3 to IS 15500 (Parts 1 to 8) : 2004 (Page 71, Part 7, Fig. 7.15) — Add Fig. 7.16 as given below:
NOTES 1 Minimum 3 centralizers should be provided; first at joint to top reducer cap of cylinder, second approximately at middle of riser pipe line and third at the bottom of top riser pipe. 2 The above centralizer is suitable for 150 NB casing pipe. It may be trimmed at R60 and R47.5 marks for use with casing pipe of 125 and 100 NB respectively.
Shore hardness 80 ± 5 on scale A. Manufacturing tolerance to be ±0.5 unless otherwise specified.
All dimensions in millimetres. FIG. 7.16 PIPE CENTRALIZER — STANDARD (SDWP)
(MED 27)
Reprography Unit, BIS, New Delhi, India 2
AMENDMENT NO. 2 MAY 2009
TO
IS 15500 (PARTS 1 TO 8) : 2004 DEEPWELL HANDPUMPS, COMPONENTS
AND SPECIAL TOOLS ― SPECIFICATION
(Page 3, clause 5.1.1) — Insert the following line at the end:
‘Front cover of Head Assembly shall be made from ‘O grade’ CRS Sheet of IS 513 : 1994.’
(Page 3, clause 5.2.1) — Substitute ‘Tensile strength 800 MPa, Min’ for ‘Tensile strength 1 030 MPa,
Min’.
(Page 3, clause 5.6.2, Shore hardness on A scale) — Substitute ‘shall be as specified in the Fig. 7.1 to
7.15’ for ‘80 5
4
+
−
’.
10
9
8
7
6
5
4
3
2
1
1
2
1
1
1
1
1
1
1
2
Hexagonal Nut ― M12
Gusset ― Standard
Front Bottom End Plate
Front Top End Plate
Axle Bush ― Left
Axle Bush ― Right
Bracket ― Standard
Back Plate ― Standard
Head Flange
Side Plate
Std 04
Fig. 4.3K
Fig. 4.3J
Fig. 4.3I
Fig. 4.3H
Fig. 4.3G
Fig. 4.3D
Fig. 4.3C
Fig. 4.3B
Fig. 4.3A
Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Annex B
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Part
No.
No.
Off
Description Reference Material
NOTES
1 Inside fillet welding of side plates and back plate to flange should be 3.2 mm, Min.
2 Welding fillet in other places should be 4 mm, Min. 3 The side plate shall be welded inside and outside as shown in the drawing.
4 The head assembly shall be welded inside and outside. The outside seal welding run shall be ground smooth.
5 Reaming of the left and right axle bushes shall be done to ensure internal dimensions and alignment.
Manufacturing tolerance to be ±0.5 unless otherwise specified.
Price Group 2
1
(For SDWP, VLOM-65 and VLOM-50)
FIG. 4.1 HEAD — STANDARD
All dimensions in millimetres.
Amend No. 2 to IS 15500 (Parts 1 to 8) : 2004
(Page 28, Fig. 4.2) — Substitute the following for the existing figure:
10
9
8
7
6
5
4
3
2
1
1
2
1
1
1
1
1
1
1
2
Hexagonal Nut ― M12
Gusset ― EDWP
Front Bottom End Plate
Front Top End Plate
Axle Bush ― Left
Axle Bush ― Right
Bracket ― EDWP
Back Plate ― EDWP
Head Flange
Side Plate
Std 04
Fig. 4.3L
Fig. 4.3J
Fig. 4.3I
Fig. 4.3H
Fig. 4.3G
Fig. 4.3F
Fig. 4.3E
Fig. 4.3B
Fig. 4.3A
Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Annex B
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Grade A IS 2062
Part
No.
No.
Off
Description Reference Material
NOTES
1 Inside fillet welding of side plates and back plate to flange should be 3.2 mm, Min.
2 Welding fillet in other places should be 4 mm, Min. 3 The side plate shall be welded inside and outside as shown in the drawing.
4 The head assembly shall be welded inside and outside. The outside seal welding run shall be ground smooth. 5 Reaming of the left and right axle bushes shall be done to ensure internal dimensions and alignment.
FIG. 4.2 HEAD — EDWP
All dimensions in millimetres.
Manufacturing tolerance to be ±0.5 unless otherwise specified.
2
Amend No. 2 to IS 15500 (Parts 1 to 8) : 2004
(Page 30, Fig. 4.3D) — Substitute the following for the existing figure:
Manufacturing tolerance to be ±0.5 unless otherwise specified.
All dimensions in millimetres.
FIG. 4.3 PARTS OF HEAD (Continued)
(Page 31, Fig. 4.3F) — Substitute the following for the existing figure:
3
FIG. 4.3 PARTS OF HEAD (Continued)
All dimensions in millimetres.
Amend No. 2 to IS 15500 (Parts 1 to 8) : 2004
(Page 59, Fig. 6.2) — Substitute ‘6.5 min.’ for ‘6 min.’.
(Page 61, Fig. 6.8) — Substitute ‘Ø 26.5 ± 0.2’ for ‘Ø 26 ± 0.2’.
4
Reprography Unit, BIS, New Delhi, India
(MED 27)
AMENDMENT NO. 1 MARCH 2007TO
IS 15500(PARTS 1TO 8) :2004DEEP WELL HANDPUMPS, COMPONENTSAND SPECIAL TOOLS — SPECIFICATION
(Page 3, Part 1, clause 5.2.1, second line) — Substitute ‘Steel designation X04 Cr 19 Ni 9’Jor ‘Grade04 Cr 18 Ni 10’.
(Page 38, Part 4, Fig. 4.10) — Substitute the following for the existing figure:
t-125 75 , 75
+125
-1
I --kki---pq-
Manufaetuting tolerance to be +0.5 unless otherwise specified.
All dimensions inmillimetres
FIG. 4.10 T-BAR(For EDWP only)
Price Group 3
Amend No. 1 to IS 15500 (Parts 1 to 8): 2004
(Page 38, Part 4, Fig. 4.11) — Substi~te the following for the existing fi~:
CounterWeight Requirement
m
CylinderSetting vii~h~
Upto60m None60mto Tom One70m to 80m Two80mto $)Orn Three
3 Holes 013.5’Spaced as shown
M30
Manufsdudngtolersn~tobeiO.5 unlessoth~~ specifid.
Alldimensimsinmlllimdres.
[Page 41, Part 4, Fig. 4.14F (up~r text)] –Substitute ‘To stit OD of 15CIm Pipe (mtium)’ for ‘Tosuit OD of 175 .NBPipe (mediu)’.
(page 49, Part 4, Fig.428) — s&ti~~e ’51 ~mu~~or ~50k2,
2
Amend No. 1 to IS 15500 (Parts 1 to 8): 2004
(Page 53, Part 5, Fig. 5.3) – Substitute the following for the existing figure:
TR37
Jlv’)II II I
‘*NIr
IR2 I
I+1 5 ! Iv
I.
085 01
l–
Vzf I2 Ribs, 3x2I —
Ezi
I iI
f
I II
I IIIII
III
I
~II
I III
“~I I
,1IIII
iI
‘Diametricallyoppositeandraised
“.-
d-.PF’ 051.85 0
L G ~ (IS 2843)1)
1) Indicatescriticaldimensions
-1
Alldimensionsinmillimetres
FIG. 5.3 CYLINDERBoDY-VLOM 50
3
Amend No. 1 to IS 15500 (Parts 1 to 8): 2004
(Page 55, Part 5, Fig. 5.5B) — Subtimte the folloting for the etistkg fi~e:
IKJ I
. .
LB II
1 W_/‘C&l
I I
5.5B BOITOM CAP - VLOM+35
1) Indicates criticaldimensions
All dimensionsin millimetres. ..
I
I
I
,/I/I
Amend No. 1 to IS 15500 (Parts 1 to 8): 2004
(Page 59, Part 6, Fig. 6.2) — Substitute‘049’Jor ‘044’.
(Page 59, Part 6, Fig. 6.2) — Substitute 619l’Y for’ 16 ‘“2 and substitute ’19 A/F’ for ’18 A/F’ in the
first line of ‘NOTE’.
(Page 59, Part 6, Fig. 6.4) — Substitute the following for the existing figure:
1)
3.
+0.80500
‘1) lndkatescriticaldimensions.
Alldimensionsin millimetres.
FIG.6.4 BUCKETSPACER-STANDARD(ForSDWP,EDWP& VLOM65)
(Page 59, Part 6, Fig. 6.5) — Substitute the foiiowing for the existing figure:
1
{1 I I
:R5*0.5
II I
z
? i I
3.5io.l
1)
1) Indicstesaitiwl dimensions.
Aildimensionsin millirnstres.
FIG.6.5 BUCKETSPACER-LOWER(ForEDWP)
5
Amend No. 1 to IS 1SS00 (Parts 1 to 8): 2004
(Page 60, Part 6, Fig. 6.6) — Substitute the following for the existing figure:
G Ii B (IS 2643)1)
= cm
m’
r 1-m. 060*0.3’)
1) Indicates critical dimensions
All dimensions in millimetres
FIG.6.6 FOLLOWER-SDWP
(Page 62, Part 6, Fig. 6.11) — Substitute ‘17 ‘%3’for’16 ‘%5’.
(Page 103, Part 8, Fig. 8.3.3, fmrth co!umn of the table) — Substitute ‘Fig. 8.2.4B’~or ‘Fig. 8.3,4D’
(ME 27)
Reprography UniLBIS, New Delhi, India
IS 15500 (Part 1) :2004
Indian Standard
DEEPWELL HANDPUMPS, COMPONENTS ANDSPECIAL TOOLS — SPECIFICATION
PART 1 GENERAL
1 SCOPE
1.1 This part covers the following handpumps,including components thereof and special toolsrequired for their installation/maintenance, suitable forlifting water from deep set borewells, covering staticwater level (SWL) range from 20 m to 90 m:
Deepwell handpump — STANDARD (SDWP)
Deepwell handpump — VLOM 65 (VLOM-65)
Deepwell handpump — VLOM 50 (VLOM-50)
Deepwell handpump — EXTRA DEEP (EDWP)
1.2 The size of the borewell and the range of staticwater level for each pump is given in Table 1.
Table 1 Borewell and Range of Static WaterLevel for Pumps
sl Handpump Borewell/ SWLNo. Type Casing Size
(NB, Min) (Range)
(mm)’- (m)
(1) (2) (3) (4)
i) STANDARD 100 20-40
ii) VLOM-65 125 20-30
iii) VLOM-50 I00 20-50
iv) EXTRA DEEP 100 40-90
1.3 The construction, dimensions, materials and otherspecifications of the pumps, their components, andspecial tools have been categorized in the followingeight parts:
Part 1 General
Part 2 Handpumps
Part 3 Handpump sub-assemblies
Part 4 Steel components
Part 5 Cast iron components
Part 6 Brass/bronze components
Part 7 Rubber components
Part 8 Special tools
1.3.1 The requirements of this part shall be followedin all other parts wherever applicable.
2 REFERENCES
The standards listed at Annex A contain provisionswhich through reference in this text, constituteprovisions of this standard. At the time of publication,the editions indicated were valid. All standards aresubject to revision, and parties to agreements basedon this standard are encouraged to investigate thepossibility of applying the most recent editions of thestandards.
3 NOMENCLATURE
A brief description of the main constituents of adeepwell handpump is given in Fig. 1.1.
3.1 Pump Head Assembly
The above ground mechanism operating the plunger.
3.2 Cylinder Assembly
Contains plunger, check valve, etc, lifting waterupward in each stroke.
3.3 Connecting Rod
Provides linkage between the pump head and cylinder.
3.4 Riser Pipe
Carries water from the cylinder to the water tank.
4 DIMENSIONS AND TOLERANCES
4.1 The material, dimensions and tolerances fordifferent components/assemblies shall be as providedin respective figures given in Parts 2 to 8.
NOTE — Figure pertaining to a specific pump or pumps, hasan indication to this regard in its title. The figures withoutsuch reference are common to ail the pumps.
4.2 Unless otherwise specified, the tolerance on theun-machined dimensions related to the following itemsused in the pump production, shall be governed by theirrespective Indian Standards:
a) Hot/cold rolled carbon steel plates, sheets, flatand bars;
b) Steel sections;
c) Brass tube; and
d) Cast ironibronze castings.
1
IQ
80
E
R
100 —
E60
I
A
FOUNDATION760x760x400DEEP I/ I
CEMENT CONC. IMIX 1:2:4 INSTALLATION ~
~MARK r- ___
TO DRAINORSOAK PIT — SLOPE I:50
r . .-~”. _!
cJj
‘..”....
NOTES
1 The free end of the casing pipeshallbeminimum300 mm above the installationmark.
2 Casing pipe is not required when the bore pipe passes through rocks.
3 Separate platform for washing clotheshrtensils and cattle truffs may be provided,if required. $CASING PIPE
CONNECTING RO
All dimensions in millimetres.
FIG. 1.1 TYPICALSET-UPFORDEEPWELLHANDPUMP
k HEAD ASSEMBLY
THIRD PLATE
~ WATER TANK
STAND
1000 1co
—t--1
p-
. ...” . 120
-- . . .. ...,’+ ., .,. ,., %. ..=* . .
.-. .:* “ “: GROUND..”.-*“::’” “z:. ““:*i:. .+ “.” .,.~ ,,.. ,. 80,. ...::,*. ‘. , ::
.,”
: !:: ~
L ., .,:
_ RISER PIPE
~ CYLINDER ASSEMBLY
(nmo0
IS 15500 (Part 1) :2004
4.2.1 For all other linear and angular dimensions(including fillet radii and chamfer height) wheretolerances are not specified, the tolerance as perClass C (coarse)ofIS2102 (Part 1) shall be followedfor the manufacturing of the components. However,as also stated in 6 of the referred standard, any deviationon such dimensions, observed during the inspectionof the final product, shall not lead to rejection unless itadverse!y affects the performance and durability of thecomponent/assembly/handpump.
4.3 Some components are likely to undergo minorchanges in the dimensions after welding and/oranti-corrosive treatment, The dimensions on suchcomponents shall be checked before the aboveprocesses.
4.4 The tolerance of metric thread shall conform toIS 14962 (Part 3), Class 6g for bolts and 6H for nuts.
4.5 Till such time adequate gauging practices areavailable for knuckle threads, interchangeabilitybetween the mating components shall be ensured.
4.6 The standard parts like fasteners, ball bearings etc,used in the handpump assembly and sub-assembliesshall be as per specifications given in Annex B.
4.6.1 All bolts, nuts and washers except high tensilebolts shall be electro-galvanized conforming to IS 1367(Part 11).
5 RAW MATERIALS
5.1 Steel
5.1.1 The mild steel plates/sheets, angle iron, seamlesstube, round/square bars used for the manufacture ofthe pump components shall conform to Grade A ofIS 2062.
5.1.2 The mild steel bright bar shall be of Type 4 ofIS 9550 with mechanical properties as follows:
Tensile strength 540-790 MPa, and
Elongation 12 percent, Min
5.1.3 The hexagonal coupler, generally manufacturedfrom cold drawn bars shall be stress relieved beforewelding to avoid cracks.
5.2 Stainless Steel
5.2.1 The material for stainless steel connecting rodand plunger rod shall conform to Grade 04 Cr 18Ni 10of IS 6603 with following mechanical properties:
Tensile strength 1030 Mpa, Min
Elongation 15 percent, &fin
5.2.2 The handle axle and push rod shall bemanufactured from stainless steel having followingproperties:
Chemical Composition
Carbon 0.12-0.25 percent
Manganese 14-15 percent
Chromium 16.5-18 percent
Nickel 1-1.75 percent
Nitrogen 0.32-0.40 percent
Phosphorus 0.030 percent, Max
Sulphur 0.030 percent, Max
Silicon 0.5 percent, Max
Physical Properties
Yield strength 448 MPa, Min
Tensile strength 758 MPa, Min
Elongation 30 percent, Min
Hardness 98 HRB, Max
5.3 Cast Iron
Grey iron castings shall conform to Grade FG 200 orhigher grade of IS 210.
5.4 Brass
The brass tube used for cylinder lining shall conformto grade Cu Zn 30 As of IS 407 and shall be temperannealed.
5.5 Bronze
5.5.1 Bronze castings shall conform to Grade LTB 2of IS 318 with hardness 55 HB, Min. AlternativelyNaval Brass conforming to IS 6912 can be used to forgethe components.
5.5.2 Bronze castings shall be free from leadsegregation.
5.6 Rubber
5.6.1 Rubber components shall be manufactured fromnitrile rubber compound as established by test methodgiven in IS 3400 (Part 22).
5.6.2 The physicalpropertiesofnitrile tubber componentsshall be as given below:
Shore hardness on A scale 80;:Tensile strength 12.6 MPa, Min
Elongation at break 150 percent, Min
Compression set, 24 h at 70°C 20 percent, Max
Volume change, 22 h at 40”C +25 percento
The above properties shall be checked as per thefollowing Indian Standards:
Shore hardness IS 3400 (Part 2)
Tensile strength, elongation IS 3400 (Part 1)
Compression set IS 3400 (Part 10)
Volume change IS 3400 (Part 6)
3
IS 15500 (Part 1) :2004
5.6.3 Ifitisnot possible tocarry outsometests onthecomponent itself, test shall be carried out on press curedslabs made from the same mix and vulcanizedas closely as possible to the same degree as thecomponent.
5.7 Test Records
5.7.1 The manufacturer shall maintain the record oftest certificates for each batch of the raw materialsprocured and used for manufacture of the components(both for in-house or outsourced items).
5.7.2 Daily production records shall be correlated withthe raw material batch used in production.
6 ANTI-CORROSIVE TREATMENT
6.1 Electro-galvanizing
The following components shall be electro-galvanizedand passivated conforming to service condition No. 4Ofls 1573:
a) Connecting rod (mild steel),
b) Bearing spacer, and
c) Washer.
6.1.1 The cleaning of electro-galvanized threads ispermitted to achieve necessary titment.
6.2 Galvanizing
The following parts shall be hot dip galvanizedaccording to IS 4759:
a) Stand,
b) Water tank,
c) Head,
d) Cover,
e) Handle,
f) Third plate,
g) T-bar (EDWP),
h) Counter weight (EDWP),
j) Socket for riser pipe, and
k) Cone plate.
6.2.1 Galvanized assemblies shall be given chromateconversion coating according to 5.9 of IS 2629.
6.3 Painting
6.3.1 Exterior surfaces of cast iron components shallbe given the following treatment
a)
b)
One coat of red oxide primer, conforming toIS 2074.
Two coats of synthetic enamel paintconforming to IS 2932.
4
6.3.2 Chain coupling shall be given a coating each ofepoxy primer and paint.
6.3.3 Chain assembly shall be boiled in graphite greasefor better anti-corrosion.
7 WORKMANSHIP
7.1 All components shall be free tlom rough edges,burrs and other surface defects. The sharp machined-edges shall be filed smooth.
7.2 Flanges shall be reasonably flat to provide propermatching of the holes to ensure unrestricted insertionof the bolts when assembled with counterpart.
7.3 Castings shall be sound, clean and free from gascavities, blowholes, hard spots, cold shuts, distortionand other harmfhl defects. They shall be well dressedand fettled.
7.3.1 Unless otherwise specified, the castings shall haveall edges rounded off and corners filleted to 3 mmradius.
7.3.2 Castings shall not be repaired or welded.
7.4 The brass liner shall have smooth finish and shallbe free from pitting and scoring mark. No cracks inbrass tube shall be permissible on flaring.
7.5 Welding
7.5.1 Welding of mild steel components shall be donein accordance with IS 9595.
7.5.2 Welding for stainless steel components shallconform to IS 2811. Alternatively, stainless steelcomponents may be weIded by manual arc weldingusing suitable electrodes conforming to IS 5206.
7.5.3 Unless otherwise specified, the minimumspecified thickness of the metal to be welded shall bethe guiding factor for deciding the weld fillet size. Itshall normally be not less than the metal specifiedthickness of the metal to be welded.
7.5.4 All welding shall be free from blow holes, pinholes, cracks, etc.
8 RISER PIPES
8.1 Riser pipes shall be hot dipped galvanized,screwed and socketed pipe conforming to IS 1239 ‘(Part 1) medium class with special emphasis on therequirements given in 6.4. Pipe ends shall havesmooth finish and shall be free of burrs or sharpmachining chip. Internal surface of pipes shall nothave any lump of zinc. One end of each riser pipeshall be f~ed with a hot dipped galvanized socketand the other end with a thread protector. The nominalbore and length of each pipe for different handpumpsshall be as given in Table 2.
,.. .
Table 2 Riser Main Details
(Clause 8.1)
k) i 1 I ,(2) (3) (4) (5) 1
} i) STANDARD 32 3,,,_J Fig.428
ii) VLOM-65 653 ooo_5:
Fig.4.30
iii) VLOM-50 503000.J
Fig. 4.29
iv) EXTRADEEP 32 3 ooo_2;Fig. 4.28
I I I 1 , ,
8.1.1 50 mm NB riser pipes shall pass free bore testusing 50 mm diameter mandrel.
8.1.2 The socket for riser pipe shall be manufacturedfrom seamless pipe according to IS 1239 (Part 2), ormachined from solid bar conforming to Grade A of1S 2062 and shall be hot dipped galvanized. Thedimensions of the socket shall be as per drawingmentioned in Table 2.
8.1.3 Poly-tetra-flouro-ethy lene (PTFE) tape or itsequivalent shall be used on the riser pipe joints beforeinstallation.
9 TESTING
9.1 Lot
For the purpose of testing, group of each type ofassembly, sub-assembly or component covered indifferent parts shall be treated as a separate lot.
9.2 Visual Tests
All the constituents in a lot shall be examined forworkmanship, finish and visual defects.
9.3 Sampling
9.3.1 Samples shall be drawn from the constituents ofthe lot conforming to the requirements given in 9.2.
9.3.2 Unless otherwise specified in the contract ororder, the procedure given in 1S2500 (Part 1) shall befollowed for sampling inspection.
9.3.3 Unless otherwise mentioned, for thecharacteristics given in testing clause of all the parts,the single sampling plan with general inspection level Iand AQL of one percent as given in Table 1 and II-Aof 1S2500 (Part 1) shall be followed.
9.4 Dimensional and Other Tests
Samples drawn as per 9.3 shall be checked for the
IS 15500 (Part 1) :2004
following tests depending on the assembly, sub-assembly or component the lot is comprised of.
9.4.1 Head Assembly
9.4.1.1 All flanges in the head assembly lot shall bereasonably flat to provide proper matching of the holesto ensure unrestricted insertion of the bolt.
9.4.1.2 The head assembly shall be put on the Ievelledwater tank bolted to a stand and subjected to the checksgiven below:
a)
b)
c)
d)
e)
The alignment of the chain with respect tothe guide bush shall be checked. For thispurpose a rod of 12 mm diameter and 100mm length shall be fitted to the chaincoupling. The handle shall be raised andlowered gently. The rod shall pass throughthe guide bush having a hole of 13.5 + 0.5 mm,welded on a third plate specially fabricatedfor the test.
The handle shall have reasonably goodsurface contact with the top and bottomportions of the bracket.
The handle. shall be checked for lateral playat the end of square section of the handle,which shall not exceed 2 mm on the eitherside.
The clearance between the handle and thebracket shall not be less than 1.5 mm.
The stroke of the pump shall be as providedin Table 3.
Table 3 Stroke Length and Discharge of Pumps
(Clauses 9.4.1.2 and 9.4.3.4)
SI Handpump Stroke DkchargeNo. Type Length Minimum
mm Iitres
(1) (2) (3) (4)
O STANDARD 125*4 15
ii) VLOM-65 125+4 15
iii) VLOM-50 125+4 10
iv) EXTRA DEEP 100+4 12
9.4.1.3 All the head assemblies shall be dismantledand checked for the following:
a) The fitment of the bearings shall be checkedfor requirements given in 9.4.2.1.
b) All the components shall be checked forcritical dimensions in conformance with therelevant figures in Part 4.
c) When head is re-assembled with handle
5
IS 15500 (Part 1) :2004
assembly, itshall bepossible to insert handleaxle by using a soft hammer/mallet.
9.4.2 Handle Assembly
9.4.2.1 The fitment of the bearing shall be checked toensure that the outer race of the bearing does not movewhen mild force is applied on inner race of the bearingand the inner race of the bearing shall rotate freely.
9.4.2.2 When assembled with the pump head, thehandle assembly shall be tested for the requirementsgiven in 9.4.1.2.
9.4.2.3 All the components shall be dismantled andchecked for critical dimensions in conformance withthe relevant figures in Part 4.
9.4.3 Cylinder Assembly
9.4.3.1 The cylinder assemblies shall be checked forleakage in the following manner:
The cylinder, with the check valve in place, shallbe fitted with one length of riser pipe. Theassembly shall be filled with water and kept invertical position for 10 min. There shall be noleakage of water from the check valve or the caps.
9.4.3.2 The valve assemblies shall be checked for therequirement given in 9.4.4.
9.4.3.3 Two cylinder assemblies shall be dismantledand checked for the following:
a)
b)
c)
The brass liner shall be fitted in the cylinderbody in such a manner that it does not rotatefreely with the application of hand force afterflaring.
All the components shall be checked forcritical dimensions in conformance with therelevant figures in Parts 5 to 7.
In addition, the plunger rods shall be checkedfor straightness and thread-formation.
9.4.3.4 Two cylinder assemblies(other than those selectedfor dimensional checks) shall be placed fully submergedin water in a barrel of 200 Iitres capacity. The test shallstart only after getting continuous flow of water throughthe spout. The water shall then be collected in a containerfor 40 continuous strokes to be completed in one minuteand the discharge thus measured shall not be less thanthe values given in Table 3.
9.4.4 Valve Assemblies
9.4.4.1 The check valve/phrnger valve/bobbin shall bechecked for free movement in the assembly.
9.4.4.2 All the components shall be dismantled andchecked for critical dimensions in conformance withthe relevant figures in Parts 6 and 7.
9.4.5 Components
The critical dimensions of all the components shall bechecked for conformance with the relevant figure givenin the respective part.
9.4.6 Criteria for Conformity
A lot shall be considered conforming to therequirements of the standard, if the batch selectedaccording to 9.3 satisfi the criteria for conformity givenin the corresponding part depending on the assembly,sub-assembly or component it is comprised of.
10 GUARANTEE
The pumps and accessories shall be guaranteed for 12months from the date of installation or 18 months fromthe date of supply whichever is earlier against poorworkmanship/bad material. The life of the rubbercomponents shall, however, be guaranteed for only 6months from the date of supply.
11 MARKING
11.1 The pump head assembly shall have a nameplateincorporating the name and address of themanufacturer, and a serial number correlating it withthe production records.
11.2 A code/serial number shall also be punched onthe raised portion of the cylinder body, correlating itwith the production records.
11.3 The connecting rod shall have steel punchimpression indicating manufacturer’s identificationmark, month and year of manufacture on the 50 mmlong hexagonal coupler.
11.4 The folIowing shall be marked on the upper sideof bottom flange of water tank in minimum 10 mmsize and it shall be legible after galvanizing:
32 — For SDWP and EDWP
50 — For VLC)M-50
65 — For VLOM-65
11.5 All individual $omponents shall bear themanufacturers’ identification mark as specifiedin 11.5.1. The location of the marking will be soselected that it does not interfere with the performance/functioning of the component.
11.5.1 The head flange, handle, third plate, cone plate,water tank top flange, cover plate and stand flange shallhave steel punch impression of the identification markpunched before galvanizing. The impression shall bedeep enough so that they shall not be covered undergalvanizing.
11.5.2 The stainless steel components shall have steelpunch impression of the identification mark.
6
1S 15500 (Part 1) :2004
11.5.3 The cast iron components shall have the markin raised letters. In addition, the cylinder body shallalso bear year of manufacture marked in the samemanner.
11.5.4 The bronze components shall have the mark inraised letter or steel punched.
11.5.5 The rubber components shall have the markembossed during moulding, except that:
a) The components where embossing is notpractical, the marking shall be done withwaterproof ink printing; and
b) For O-rings, the marking shall be done on thepacking.
11.6 BIS Certification Marking
11.6.1 The handpumps, individual components andspecial tools may also be marked with the Standard Mark.
11.6.2 The use of the Standard Mark is governed bythe provisions of the Bureau of Indian Standards Act,1986 and the Rules and Regulations made thereunder.The details of the conditions under which the licensefor the use of the Standard Mark maybe granted to themanufacturers or producers maybe obtained fkom theBureau of Indian Standards.
12 PACKING
12.1 Unless otherwise specified in the contractor order,the packing procedure mentioned in Annex C shall befollowed.
12.2 External threads of all the threaded componentsshal1be fitted with suitable thread protectors to avoidtransit damage.
12.3 Riser pipe shall be packed as per procedure laiddown in IS 4740, unless otherwise specified by thepurchaser.
IS 15500 (Part 2) :2004
Indian Standard
DEEPWELL HANDPUMPS, COMPONENTS ANDSPECIAL TOOLS — SPECIFICATION
PART 2 HANDPUMPS
1 SCOPE
1.1 This part specifies the requirements of completeassembly of each type of handpumps (SDWP,VLOM-65, VLOM-50 and EDWP) covered in thisstandard.
1.2 The handpump assemblies covered in this part shallbe exclusive of riser pipes.
1.3 This part shall be read with Part 1. Stipulationsprovided therein, whichever relevant to the productscovered in this part, shall apply.
2 CONSTRUCTION
2.1 The assembly detail of different types ofhandpumps covered in this part shall be as given inFig. 2.1 to 2.4.
2.2 The assembly detail of individual sub-assemblyshall be as given in the related figure in Part 3.
2.3 The material and dimensions of the individualcomponent shall meet the requirements given in therelated part of this standard
3 TESTING
3.1 Group of each type of handpump covered in thispart shall be treated as a separate lot.
3.2 Test samples shall be drawn as per proceduredescribed in 9.3 of Part 1.
3.3 Sub-assemblies and other components of thehandpumps selected as per 3.2 shall be tested as givenbelow.
3.3.1 Head and Cylinder Assemblies
The head and cylinder assemblies shall be checked as
per the detail given in 9.4.1 and 9.4.3 respectively ofPart 1.
3.3.2 Other Components
All other steel and rubber components of the pumpassembly not covered under 3.3.1 shall be checked forthe tests given in 3 of Part 4 and also in 3 of Part 7respectively.
3.4 Criteria for Conformity
3,4.1 The lot of the pumps shall be consideredconforming to the requirements of the standard, if thebatch .selected according to 3.2 satisfies therequirements given in 3.4.2.
3.4.2 The number of samples not meeting therequirements of a characteristic, inspected under 3.3.1and 3.3.2, does not exceed the correspondingacceptance number as specified in IS 2500 (Part 1).
4 MARKING
The requirements given in 11 of Part 1 shall apply.
5 PACKING
5.1 In addition to the requirements given in 12.1and 12.2 of Part 1,the following conditions shall applyfor the head assembly.
5.1.1 Handle shall be locked in position with somesuitable arrangement before packing the head assembly.
5.1.2 An extra hexagonal nut (Std 04 in Annex B) shallbe attached to chain for use of locking the lastconnecting rod with chain coupling.
5.1.3 The chain shall be smeared with graphite greaseand covered with a polyethylene bag prior to dispatch.
8
IS 15500 (Part 2) :2004
..
m ./-fl’(hI
// J’@
u9
(Y2
1
I
‘o5
9
‘-@
i-i-10987654321
GNo.—
—***
817*
11111
GMI—
&k%8L. -3
7
Casing PipePipe Socket — 32Riser Pipe, 32NBHex Bolt —M12 x 40Hex Nut —M12Connecting RodWater Tank — StandardNormal Stand — StandardThird PlateCylinder Assembly — SDWPHead Assembly — Standard
Description
1-
TablelFig. 4.28Table 2Std 12Std 04Fig. 4.21Fig. 4.15Fig. 4.12Fig. 4.5Fig. 3.5Fig. 3.1
Reference
* Depending on the field conditions/pump settings
— —Mild Steel tL12 of Part 1Mild Steel 8.1 of Part 1Steel Annex BSteel Annex BBright Bar 5.1.2 of Part 1
— l–— —
Mild Steel Grade A of IS 20fi— l—— —
“ .Material
4
“
FIG.2.1 DEEPWELLHANDPUMP— STANDARD(SDWP)
9
IS 15500 (Part 2) :2004
i (3’13
0’12
II
J_I
(!!!
F-@o5I
o8
‘o 7
1413
121110987654321
PartNo.—
r-w
mL
I
* Casing Pipe lTable 11 f
* Pipe Socket — 65
* Riser Pipe, 65 NB8 Hex Bolt —M12 x 40
17 Hex Nut —M123 Pipe Centralizer — VLOM-65I Compression Cone — VLOM-65* Connecting Rod1 Cone Plate1 Water Tank — 651 Telescopic Stand — Standard1 Third Plate1 Cylinder Assembly — VLOM-6$1 Head Assembly — Standard
Fig. 4.30
Table 2Std 12Std 04Fig. 7.14Fig. 7.12Fig. 4.21Fig. 4.19Fig. 4.17Fig. 1.12Fig. 3.5Fig. 3.7Fig. 3.1
— —Mild Steel 8.1.2 of Part 1
Mild Steel 8.1 of Part 1Steel Annex BSteel Annex BNitrile Rubber 5.6 of Part 1Nitrile Rubber 5.6 of Part 1Bright Bar 5.1.2 of Part 1
I — I —— —— —
Mild Steel Grade A of IS 2062— —
l–l-1
~o. Description Reference MaterialMT
* Dependingon the field conditions/pumpsettings.
FIG.2.2 DEEPWELL HANDPUMP— VLOM-65
10
IS 15500 (Part 2) :2004
10’13
G’12
u2
35I
38
‘o14
‘o 7
1141312111098765432
k1
PartNo.
#+-l
L11
t-.-J
10
I I
131*
11II1
I
No.off
—
8.1.2 of Part I8.1 of Part 1Annex BAnnex B
pipe Centralizer — VLOM-50 Fig. 7.15 Nitrile Rubber 5.6 of Part 1
Compression Cone — VLOM-50 Fig. 7.13 Nitrile Rubber 5.6 of Part 1
Connecting Rod Fig. 4.21 Bright Bar 5.1.2 of Part 1
Cone Plate Fig. 4.19 — —
Water Tank — 50 Fig. 4.16 — —
Normal Stand — Standard Fig. 4.12 — —
Third Plate Fig. 4.5 Mild Steel Grade A of IS 20&
Cylinder Assembly— VLOM-50 Fig. 3.9 — —
Head Assembly — Standard Fig. 3.1 — —
Description Reference Material
II I I
*Dependingou field conditions/pumpsettings.
FIG. 2.3 D~EPWELL HANDPUMP — VLOM-50
11
.
T
IS 15500 (Part 2) :2004
//
I
I
C4/0’13
012
d8
d2
1413121110987654321
‘artNo.
?3hl
14
***
38
20*
11*
1111
ICasing Pipe ITable 1Pipe Socket — 32 mm NB Table 2Riser Pipe — 32 mm NB Table 2Hex Bolt — M12 (see Note) Std 13Hex Bolt —M12 X40 Std 12Hex Nut —M12 Std 04Connecting Rod Fig. 4.21Water Tank — Normal Fig. 4.15Normal Stand — EDWP Fig. 4.13Counter Weight Fig. 4.11T-Bar Fig. 4.10Third Plate Fig. 4.5Cylinder Assembly — EDWP Fig. 3.11Head Assembly — EDWP Fig. 3,3
I
Vo. Description IReferenceDff/ I
— —Mild Steel 8.1.2 of Part 1Mild Steel 8.1 of Part 1Steel Annex BSteel Annex BSteel Annex BBright Bar 5.1.2 of Part 1
— —— —
Mild Steel Grade A of IS 2062Mild Steel Grade A of IS 2062Mild Steel Grade A of IS 2062
— —— —
Material
* Depending on field conditionsipump.settings.
NOIE — In caseof item 11, the bolt length will depend upon the number of counter weight.
FIG. 2.4 D~~PWELL HAN~PUMP — EXTRA DEEP (EDWP)
12
IS 15500 (Part 3) :2004
Indian Standard
DEEPWELL HANDPUMPS, COMPONENTS ANDSPECIAL TOOLS — SPECIFICATION
PART 3 HANDPUMP SUB-ASSEMBLIES
1 SCOPE
1.1 This part specifies the requirements of individualsub-assemblies used to assemble each type of handpump (SDWP, VLOM-65, VLOM-50 and EDWP)covered in this standard.
1.2 This part shall be read with Part 1. Stipulationsprovided therein, whichever relevant to the componentscovered in this part, shall apply.
2 CONSTRUCTION
2.1 The assembly details of different handpump sub-assemblies covered in this part shall be as given inFig.3.1to 3.12.
2.2 The material and dimensions of the individualcomponent shall meet the requirements given in therelated part of this standard.
3 TESTING
3.1 Group of each type” of sub-assembly covered inthis part shall be treated as a separate lot.
3.2 Test samples shall be drawn as per proceduredescribed in 9.3 of Part 1.
3.3 Depending on the type of sub-assembly, thesamples drawn as per 3.2 shall be tested as givenbelow.
3.3.1 Head Assembly
The head assembly shall be examined as per the detailgiven in 9.4.1 of Part 1.
3.3.2 Handle Assembly
The handle assembly shall be examined as per the detailgiven in 9.4.2 of Part 1.
3.3.3 Cylinder Assembly
The cylinder assembly shall be subjected to testsdetailed in 9.4.3 of Part 1.
3.3.4 Valve Assemblies
The valve assembly shall be checked for therequirements provided in 9.4.4 of Part 1.
3.4 Criteria for Conformity
3.4.1 The lot shall be considered conforming to therequirements of the standard, if the batch selectedaccording to 3.2 satis$ the requirements given in 3.4.2.
3.4.2 The number of samples not meeting therequirements of the characteristics inspected under thecorresponding clause(s) of Part 1 as given in Table 4,does not exceed the corresponding acceptance numberas specified in IS 2500 (Part 1).
Table 4
S1No. Lot Type Refto Cl of Part 1
(1) (2) (3)
i) HeadAssembly 9.4.1ii) Handle Assembly 9.4.2
iii) Cylinder Assembly 9.4.3iv) Valve Assembly 9.4.4
4 MARKING
The requirements given in 11 of Part 1 shall apply.
5 PACKING
In addition to the requirements given in 12.1 and 12.2of Part 1, the conditions specific to the head assemblygiven in 5.1.1 to 5.1.3 of Part 2 shall be applicable.
i
13
IS 15500 (Part 3) :2004
CL7
[
71615141312111
Part No.No. off
Hexagonal Bolt — M12 x 20Hexa~onaI Nut — M12WasherHandle AxleFront CoverHead — StandardHandle Assembly — Standard
Description
-1-L —-L- —- —- A4i4 -l&
Std 10Std 04Fig. 4.27Fig. 4.24Fig. 4.4Fig. 4.1Fig. 3.2
Reference
x-x
SteelSteelMild SteelStainless SteelCRS Sheet
——
Annex BAwex BGrade A of IS 20625.2 of Part 1Oral.Grade of IS 513
—.—
Material
FIG.3.1 HEADASSEMBLYS~AN~ARD(For SDWP, VLOM-65 and VLOM-50)
14
IS 15500 (Part 3) :2004
P1
i
d3
x-x
6 2 Bearing, Single Side Shielded Std 15 Designation 20 BC 02 PP of IS 6455
5 1 Hex. Bolt — M1O x 40 (Gr 8.8) Std 09 HT Bold Annex B
4 1 Prevailing Torque Type Hex. Nut, M1O Std 03 Steel Annex B
3 1 Bearing Spacer Fig. 4.26 Mild Steel Grade A of IS 2062
2 1 Chain with Coupling Fig. 4.9 — —
I 1 Handle — Standard Fig. 4.6 — —
Part No. Description Reference Material
No. off
FIG.3.2 HANDLEASSEMBLY— STANDARD(For SDWP, VLOM-65 and VLOM-50)
15
,.
““
IS 15500 (Part 3) :2004
7 1 Hexagonal Bolt — M12 x 20 Std 10 Steel Annex B6 1 Hexagonal Nut— M12 Std 04 SteeI Annex B5 1 Washer Fig. 4.27 Mild Steel Grade A of IS 20624 1 Handle Axle Fig. 4.24 Stainless Steel 5.2 of Part 13 1 Front Cover Fig. 4.4 CRS Sheet Oral.Grade ofIS5132 1 Head — EDWP Fig. 4.2 — —1 1 Handle Assembly — EDWP Fig. 3,4 — —
Part No. Description Reference MaterialNo. off
FIG. 3.3 HEAD ASSEMBLY — EDWP
16
,.
IS 15500 mart 3) :2004
i - -
u
View ‘Z’
d3
x-x
6 2 Bearing, Single Side Shielded Std 15 Designation 20 BC 02 PP of IS 6455
5 1 Hex. Bolt — M1O x 40 (8.8) Std 09 HT Bolt Annex B
4 1 Prevailing Torque Type Hex. Nut, M 10 Std 03 Steel Annex B
3 1 Bearing Spacer Fig. 4.26 Mild Steel Grade A of IS 2062
2 1 Chain with Coupling Fig. 4.9 — —
I 1 Handle — EDWP Fig. 4.7 — —
Part No. Description Reference MaterialNo. off
FIG. 3.4 HANDLEASSEMBLY— EDWP
17
. .
‘7IS 15500 (Part 3) :2004
fll
7 3 Sealing Ring — Standard Fig. 7.3 Nitrile Rubber 5.6 of Part 16 1 Brass Line — Standard Fig. 6.1A Brass Tube CuZn30 As of IS 4075 2 Reducer Cap Fig. 5.4 Cast Iron FG 200 of IS 2104 1 Cylinder Body — Standard Fig. 5. I Cast Iron FG2000f IS2103 1 Plunger Rod — Standard Fig. 4.22 Stainless Steel 04Crl 8Ni10 of IS 66032 1 Check Valve Assembly - Standard Fig. 3.6B — —1 1 Plunger Valve Assembly — Standard Fig. 3.6A — —
Part No. Description Reference MaterialNo. off
FIG. 3.5 CYLINDERASSEMBLY— SDWP
18
IS 15500 (Part 3) :2004
1
10 I Check Valve Seating — Standard Fig. 7.7 Nitrile Rubber 5.6 of Part 1
9 1 Upper VaIve Seating Fig. 7.6 Nitrile Rubber 5.6 of Part 1
8 2 Pump Bucket — Standard Fig. 7.1 Nitrile Rubber 5.6 of Part 1
7 I Check Valve Seat — Standard Fig. 6.12 Bronze Grade LTB2ofIS318
6 I Rubber Seat Retainer Fig. 6.11 Bronze Grade LTB2ofIS318
5 I Check Valve — Standard Fig. 6.9 Bronze Grade LTB2ofIS318
4 1 Follower — SDWP Fig. 6.6 Bronze Grade LTB2ofIS318
3 1 Bucket Spacer — Standard Fig. 6.4 Bronze Grade LTB2ofIS318
2 1 Upper Valve Fig. 6.3 Bronze Grade LTB2ofIS318
1 1 Plunger Yoke Body Fig. 6.2 Bronze Grade LTB2ofIS318
Part No. Description Reference NMterialNo. off
1
{
w I
3.6A Plunger Valve Assembly — SWDP 3.6B Check Valve Assembly — SDWP
NOTE— Check valve assemblyto be punch locked on top at Ml Ojoint at diametricallyopposite two points atter filing thetwo surfaceseven.
FIG. 3.6 VALVEASSEMBLIES— SDWP
19
IS 15500 (Part 3): 2004
-ilb-111
u-l
8 2 Sealing Ring — VLOM-65 Fig. 7.4 Nitrile Rubber 5.6 of Part 17 1 Brass Liner — Long Fig. 6.1B Brass Tube CuZn30 As of IS 4076 1 Bottom Cap — VLOM-65 Fig. 5.5B Cast Iron FG2000f IS2105 1 Upper Cap — VLOM-65 Fig. 5.5A Cast Iron FG2000f IS 2104 1 Cylinder Body — Long Fig. 5.2 Cast Iron FG2000f IS2103 1 Plunger Rod — Long Fig. 4.23 StainlessSteel 04Crl8Ni 10 of IS 66032 1 Check Valve Assembly — VLOM-65 Fig. 3.8B —1 1
—Plunger Valve Assembly — VLOM-65 Fig. 3.8A — —
Part No. Description Reference MaterialNo. off
FIG. 3.7 CYLINDER ASSEMBLY — VLOM-65
20
IS 15500 (Part 3) :2004
I
I
3.8A Plunger Valve Assembly — VLOM-65 3.8B Check Valve Assembly — VLOM-65
13 1 Check Nut — M6 Std 01 Stainless Steel Annex B12 1 Q-Ring — VLOM-65 Fig. 7.10 Nitrile Rubber 5.6 of Part 111 1 Check Valve Seating — VLOM-65 Fig. 7.8 Nitrile Rubber 5.6 of Part 110 1 upper Valve Seating Fig. 7.6 Nitrile Rubber 5.6 of Part 19 2 Pump Bucket — Standard Fig. 7.1 Nitrile Rubber 5h of Part 18 1 Cage Fig. 6.14 Bronze Grade LTB2ofIS318
7 1 Check Valve Seat — VLOM-65 Fig. 6.13 Bronze Grade LTB2ofIS3186 1 Check Valve — VLOM-65 Fig. 6.10 Bronze Grade LTB2ofIS3185 1 Follower — VLOM-65 Fig. 6.8 Bronze Grade LTB2ofIS3184 1 Bucket Spacer — Standard Fig. 6.4 Bronze Grade LTB2ofIS318
3 1 Upper Valve Fig. 6.3 Bronze Grade LTB2ofIS3182 1 Plunger Yoke Body Fig. 6.2 Bronze Grade LTB2ofIS3181 1 Push Rod Fig. 6.25 Stainless Steel 5.2.2 of Part 1
Part No. Description Reference MaterialNo. off
FIG. 3.8 VALVE ASSEMBLIES — VLOM-65
21
IS15500 (Part 3):2004
8 2 Sealing Ring — VLOM-50 Fig. 7.5 Nitrite Rubber 5.6 of Part 17 1 Brass Liner — VLOM-50 Fig. 6.1C Brms Tube CuZn30 As of IS 4076 1 Bottom Cap — VLOM-50 Fig. 5.6B Cast Iron FG2000flS 2105 1 Upper Cap — VLOM-50 Fig. 5.6A Cast Iron FG2000f IS2104 1 Cylinder Body — VLOM-50 Fig. 5.3 Cast Iron FG2000f IS2103 1 Plunger Rod — Long Fig. 4.23 Stainless Steel 04Crl 8Ni10 of IS 66032 1 Check Valve Assembly — VLOM-50 Fig. 3. 10B — —1 1 Plunger Valve Assembly — VLOM-50 Fig. 3.10A — —
Part No. Description Reference MaterialNo. off
FIG. 3.9 CYLINDER ASSEMBLY — VLOM-50
22
IS15500 (Part 3):2004
3.1 OA Plunger Valve Assembly — VLOM-50 3.1 OB Check Valve Assembly — VLOM-50
7 1 Hexagonal Bolt — M6 x 25 Std 05 Stainless Steel Atmex B
6 1 Hexagonal Nut — M6 Std 01 Stainless Steel Annex B
5 1 O-Ring — VLOM-50 Fig. 7.11 Nitrile Rubber 5.6 of Part 1
4 2 Bobbin Fig. 7.9 Nitrile Rubber 5.f70f Part 1
3 I Pump Bucket — VLOM-50 Fig. 7.2 Nitrile Rubber 5.6 of Part I
2 1 Check Valve Body Fig. 6.16 Bronze Grade LTB2ofIS318
1 1 Plunger Valve Body Fig. 6.15 Bronze Grade LTB2ofIS318
Part No. Description Reference Material
No. off
FIG. 3.10 VALVEASSEMBLIES— VLOM-50
23
IS15500 (Part 3):2004
mI
7 3 Sealing Ring — Standard Fig. 7.3 Nitrile Rubber 5.6 of Part 16 1 Brass Liner — Long Fig, 6. IB Brass Tube CuZn30 As of IS 4075 2 Reducer Cap Fig. 5.4 Cast Iron FG 200 of IS 2’104 1 Cylinder Body — Long Fig. 5.2 Cast Iron FG2000f IS2103 1 Plunger Rod — Long Fig. 4.23 StainlessSteel 04Cr18Ni10of IS 66032 1 Check Valve Assembly — EDWP Fig. 3. 12B — —1 1 Plunger Valve Assembly — EDWP Fig. 3.12A — —
Part No. Description Reference MaterialNo, off
FIG. 3.11 CYLINDERASSEMBLY— EDWP
24
,,.
IS 15500 (Part 3) :2004
32
3.1 2A Plunger Valve Assembly — EDWP 3.1 2B Check Valve Assembly — EDWP
11 1 Lower Valve Seating — Standard Fig. 7.7 Nitrile Rubber 5.6 of Part 1
10 1 Upper Valve Seating Fig. 7.6 Nitrile Rubber 5.6 of Part 1
9 3 Pump Bucket — Standard Fig. 7.1 Nitrile Rubber 5.6 of Part I
8 1 Check Valve Seat — Standard Fig. 6.13 Bronze Grade LTB2ofIS318
7 1 Rubber Seat Retainer Fig. 6.11 Bronze Grade LTB2ofIS318
6 1 Check Valve — Standard Fig. 6.9 Bronze Grade LTB2ofIS318
5 1 Follower — EDWP Fig. 6.7 Bronze Grade LTB2ofIS318
4 I Bucket Spacer — Lower Fig. 6.5 Bronze Grade LTB2ofIS318
3 1 Bucket Spacer — Standard Fig. 6.4 Bronze Grade LTB2ofIS318
2 1 Upper Valve Fig. 6.3 Bronze Grade LTB2ofIS318
1 1 Plunger Yoke Body Fig. 6.2 Bronze Grade LTB2ofIS318
Part No. Description Reference MaterialNo. off
NOTE— Lowervalve assemblyto be punchlockedon top at M1Ojoint at diametricallyoppositetwo pointsaflertiling the two surfaceseven.
FIG. 3.12 VALVEASSEMBLIES— EDWP
25
. .,
i 7IS15500 (Part 4):2004
Indian Standard
DEEP~ELL HANDPUMPS, COMPONENTS ANDSPECIAL TOOLS — SPECIFICATION
PART 4 STEEL COMPONENTS
1 SCOPE
1.1 This part specifies the requirements of all steel andstainless steel components used in the assembly of eachtype of handpump (SDWP, VLOM-65, VLOM-50 andEDWP) covered in this standard.
1.2 This part shall be read with Part 1. Stipulationsprovided therein, whichever relevant to the componentscovered in this part, shall apply.
2 CONSTRUCTION
2.1 The constructional details of different componentscovered in this part shall be as given in Fig. 4.1 to4.30.
2.2 The material and dimensions shall meet the relatedprerequisites given in 4 and 5 of Part 1.
2.3 The steel components shall be given anti-corrosivetreatment as mentioned in 6 of Part 1.
3 TESTING
3.1 Group of each type of component covered in thispart shall be treated as a separate lot.
3.2 Test samples shall be drawn as per proceduredescribed in 9.3 of Part 1.
3.3 The critical dimensions of all the components
selected as per 3.2 shall be checked for conformancewith the relevant figures given in this part .
3.4 The flanges shall be reasonably flat to provideproper matching of the holes to ensure unrestrictedinsertion of the bolts when assembled with counterpart.
3.5 The connecting rockiplunger rods shall be examinedfor straightness and formation of threads.
3.6 Criteria for Conformity
3.6.1 The individual lot of components, as definedin 3.1, shall be considered conforming to therequirements of the standard, if the batch for theparticular lot selected according to 3.2 satisfy therequirements given in 3.6.2.
3.6.2 The number of components not meeting therequirements of a characteristic inspected under 3.3to 3.5 (whichever applicable) shall not exceed thecorresponding acceptance number as specified inIS 2500 (Part 1).
4 MARKING
The requirements given in 11.5.1 and 11.5.2 of Part 1shall be followed.
5 PACKING
The requirements of 12.1 and 12.2 of Part 1 shall apply.
26
IS15500 (Part 4):2004
I 250 190*
[
10 1 Hexagonal Nut — Ml 2 Std 04 Steel Annex B9 2 Gusset — Standard Fig. 4.3K Mild Steel Grade A IS 20628 1 Front Bottom End Plate Fig. 4.3J Mild Steel Grade A IS 20627 1 Front Top End Plate Fig. 4.31 Mild Steel Grade A IS 20626 1 Axle Bush — Left Fig. 4.3H Mild Steel Grade A IS 20625 1 Axle Bush — Right Fig. 4.3G Mild Steel Grade A IS 20624 1 Bracket — Standard Fig. 4.3D Mild Steel Grade A IS 20623 1 Back Plate — Standard Fig. 4.3C Mild Steel Grade A IS 20622 1 Head Flange Fig. 4.3B Mild Steel Grade A IS 20621 2 Side Plate Fig. 4.3A Mild Steel Grade A IS 2062
Part No. Description Reference MaterialNo. off
NOTES1 Inside fillet welding of side plates and back plate to flange should be 3.2 mm, Min.
2 Welding fillet in other places should be 4 mm, Min.
3 The side plate shall be welded inside and outside as shown in the drawing.
4 The head assembly shall be welded from inside and outside. The outside seal welding run shall be ground smooth.
5 Reaming of the left and right axle bushes shall be done to ensure internal dimensions and alignment.
Manufacturing tolerance to be +0.5 unless otherwise specified.
All dimensions in millimetres.
FIG.4.1 HEAD— STANDARD(For SDWP, VLOM-65 and VLOM-50)
27
,.
IS 15500 (Part 4): 2004
m
v /75 //,Vhvd A t #%/’”
17*1 / 11
‘1 250 -11- 1
10987654321
PartNo.
1
211111112
Koff
Hexagonal Nut — M12Gusset — EDWPFront Bottom End PlateFront Top End PlateAxle Bush — LeftAxle Bush — RightBracket — EDWPBack Plate — EDWPHead FlangeSide Plate
Description
Std 04Fig. 4.3LFig. 4.3JFig. 4.31Fig. 4.3HFig. 4.3GFig. 4.3FFig. 4.3EFig. 4.3BFig. 4.3A
Reference
190
SteelMild SteelMild SteelMild SteelMild SteelMild SteelMild SteelMild SteelMild SteelMild Steel
Annex BGrade A IS 2062Grade A IS 2062Grade A IS 2062Grade A IS 2062Grade A IS 2062Grade A IS 2062Grade A IS 2062Grade A IS 2062Grade A 1S 2062
Material
NOTES1 Inside fillet welding of side plates and back plate to flange should be 3.2 mm, Min. ~
2 Weldlng fillet in other places, should be 4 mm, Min.
3 The side plate shall be welded inside and outside as shown in the drawing.
4 The head assembly shall be welded from inside and outside. The outside seal welding run shall be ground smooth.
5 Reaming of the Ietl and right axle bushes shall be done to ensure internal dimensions and alignment.
Manufacturing tolerance to be +0.5 unless otherwise specified.
All dimensions in millimetres.
FIG. 4,2 HEAD— EWDP
28
IS15500 (Part 4):2004
Hole 040.5 /
I 246 I 17
4.3A Side Plate
125 125
100 100- - 1R12*1
%= +-1
e 075
I..— - -—- —
I
#
II
+-
1
—
1 l//rIIl////
++
4.3B Head Flange
Manufacturingtoleranceto be+0.5 unless otherwise specified.
All dimensions in millimetres.
FIG.4.3 PARTSOFHEAD (Continued)
29
,.
IS15500 (Part 4):2004
~ 250 ~
e —
J-‘-- Hole 014 $.2
I
- T~ \ “-
43*1
4.3C Back Plate —Standard(For SDWP, VLOM-65 & VLOM-50)
A
=1-T“” ““ 1.1.
-?I
—I
I. I .
:
1’..i._.-le --.-J-----‘1
b
A-i
-
I
I1
1
It
I
t
❑
A-A4.3D Bracket — Standard
(For SDWP, VLOM-65 & VLOM-50)
Manufacturing tolerance to be +0.5 unless otherwise specified.
All dimensions in millimetres.
FIG.4.3 PARTSOFHEAD(Continue@
30
~ 250
, 71rHole 014 -8.2
T
-IT t
v ~ &N43* I $%
4.3E Back Plate — EDWP
B
+r- ‘“ ““1
L:1I
$J[ .J --------
4,— - — —. 4
.45.5*0.3 - --”
i’
II I
1 I
-1----+-‘_+-_,
B
*
IS 15500 (Part 4) :2004
—98--+
B-B
4.3F Bracket — EDWP
Manufacturing tolerance to be +0.5 unless otherwise specified.
All dimensions in millimetres,
FIG. 4.3 PARTS OF HEAD (Conlinued)
31
IS15500 (Part 4):2004
CHF. 1X4!Y
T
ON BOTH SIDES
1020T7--
4.3G Axle Bust — Right
4.3H Axle Bust — Left
-’01
L,,o-1+0.5
t 4.3K Gusset — Standardw (For SDWP, VLOM-65 & VLOM-50)
4.3 I Front Top End Plate
Iw
4.3J Front Bottom End Plate
L-65*1.5--I4.3L Gusset — EDWP
(For EDWP)
1)[ndicate~~ritic~]di~~n~i~~~.
Manufacturing tolerance to be +0.5 unless otherwise specified.
All dimensions in millimetres.
FIG. 4.3 PARTSOFHEAD(Ccwcluded)
32
II
IS 15500 (Part 4) :2004
WELDED
8
2 Nom+1.5
100 0 2 Nom
~-------. .------- _I 1II !I1 :iI III 1I1 I
I1 1
1I 11 I
II !tI 1t II1 t 1
!11
II I It t
tII I
II 1 II 1I
t1
1 II I1 1I
1
II
*I------ —------
I
\ I
w85*1 .5
9
Manufacturing tolerance to be *0.5 unless otherwise specified.
All dimensions in millimetres.
FIG. 4.4 FRONTCOVER
33
IS 15500 (Part 4) :2004
1, 4
t////l///////I/lA /
R12M i-250 ““+
‘b 1
1-35
-i
4.5A Flange for Third Plate 4.5B Guide Bush
2 1 Guide Bush Fig. 4.5B Mild Steel Grade A of IS 20621 1 Flange for Third Plate Fig. 4.5A Mild Steel Grade A of IS 2062
Part No. Description Reference MaterialNo. off
Manufacturing toleranee to be +0.5 unless otherwise specified.
All dimensions in millimetres.
FIG. 4.5 THIRDPLATE
34
IS 15500 (Part 4): 2004
3 1 Bearing Housing “ Fig. 4.8D Mild Steel Grade A of IS 2062
2 1 Chain Guide Fig. 4,8C MildSteel GradeA of IS 20621 I HandleBar-Standard Fig. 4.8A Mild Steel Grade A of IS 2062
Part No. Description Reference Material
No. off
NOTE — Welding fillet shall not be less than 6 mm at all places.
All dimensions in millimetres.
FIG.4.6 HANDLE— STANDARD
(For SDWP, VLOM-65 & VLOM-50)
3 1 Bearing Housing Fig. 4.8D Mild Steel Grade A of IS 2062
2 1 Chain Guide Fig. 4.8C Mild Steel Grade A of IS 2062
1 I Handle Bar — EDWP Fig. 4.8B Mild Steel Grade A of IS 2062
Part No. Description Reference Material
No. off
NOTE— Welding fillet shall not be less than 6 mm at all places.
All dimensions in millimetres.
FIG.4.7 HANDLE— EDWP
35
.
IS15500 (Part 4):2004
EDGESSHALLBE
17 4.;
1+
fE3------+0.51)
170- i# MARKEDPORTIONCANBE 225*2
STRAIGHTORCANHAVE - M30+: ANVRAOIUS
1i 70*4+-
4.8A Handle Bar — Standard(For SDWR VLOM-65 & VLOM-50)
o 1)17 -0.2
❑---
---
uSq.40*1
4.8B Handle Bar — EDWP
..— .,— . .
1Q:*T *-‘ T’ “-1-
‘~T\’.. .. ,. ,.
0m
-— —- 1%.’!%@ /@$
% /’ +- ~70
R25ti SQ.12i0.5
/r
4.8C Chain Guide
DimensionA8
32 forHandle_Stsndard40 forHandle_EDWP
RO.5
B:04 -—- —-— - —
I
Manufacturingtoleranceto be *O.1 unlessotherwisespeeifiad.
4.8D Bearing Housing
1)Indicates~riticaldim~n~i~~~,
Ill dimensions in millimetres.
FIG. 4.8 PARTSOFHANDLE
36
IS 15500 (Part 4) :2004
023.5 CHF 1.5X4!Y
CHAINCOUPLING(machined)
I
023.5
CHAINCOUPLING(forged)
~ $+$I
-
+05’)L 8 O“
I b I II I
2 1 Chain Coupling — Mild Steel Grade A of IS 20621 1 Roller Chain, 25.4 Pitch Std 16 — Annex B
Part No. Description Reference MaterialNo. off
1)Indicates critical dimensions.
All dimensions in millimetres.
FIG. 4.9 CHAINWITHCOUPLING
* 37
. .
II
1S15500 (Part 4):2004
II —
:.5
--ii-l
—.— --
i
,1
1616 1=
I
1I1I
t;
I
ItIt
1;
1!
t
it
==
30
Manufacturing tolerance to be +0.5 unless otherwise specified.
All dimensions inmillimetres.
FIG. 4.10 T-BAR(For EDWP only)
Counter Weight Requirement
Cylinder Setting No. of Weights
Up to60m None60mto70m One70mto80m Two80mto90m Three
Manufacturing tolerance to be +0.5 unless otherwise specified.
All dimensions in millimetres.
013.5
3 Holes 013.5Spaced aa shown
FIG; 4.11 COUNTERWEIGHT(For EDWP only)
38.
IS 15500 (Part 4) :2004
—
4.1 2A Telescopic Stand — Standard(For borewell with 150 NB casing pipe)
8
7654321
Part No.
6
1112311
No. Off
Spikes Fig. 4. 14G
Bottom Pipe — 175 NB —Top Pipe — 150 NB —
Reducer Coller Fig. 4. 14FGusset Fig. 4. 14ELeg Fig. 4. 14DStand Flange Fig. 4.14CStand Pipe — Standard Fig. 4.14A
Description Reference
‘!!??4 -l=L-
4.12B Normal Stand — Standard(For borewell with 1001125 NB casing pipe)
Mild Steel/Bright BarSteel TubeMild Steel TubeMild SteelMild SteelHR SectionMild SteelMild Steel Tube
Grade A of IS 20621Grade 2 or 3 of IS 9550IS 1161 — medium (see Note)IS 1239 (Part 1) — mediumGrade A of IS 2062Gr@e A of IS 2062IS 808Grade A of IS 2062IS 1239 (Part 1) — medium
Material
NOTE— In case of non-availability, 175 NB pipe maybe rolled and welded from 4 mm sheet conforming to Grade A of1S 2062 keeping other dimensions as per IS 1161.
Manufacturing tolerance to be * 0.5 unlessotherwise specified
All dimensionsin millimetres.
FIG. 4.12 STAFUI— STANDARD
(For SDWP, VLOM-65 & VLOM-50)
39
1s 15500 (Part 4): 2004
AY-
Tb4InF-Jm
---lm--
4.1 3A Telescopic Stand — EDWP(For borewell with 150 NB casing pipe)
B86
7161514233211 1
Part No.No. off
Spikes
Bottom Pipe — 175 NBTop Pipe — !50 NBReducer CollerGussetLegStand FlangeStand Pipe — Standard
Description
4.1 3B Normal Stand — EDWP(For borewell with 100/125 NB casing pipe)
Fig. 4. 14G Mild Steel/Bright Bar
— Steel Tube— Mild Steel Tube
Fig. 4. 14F Mild SteelFig. 4. 14E Mild SteelFig. 4. 14D HR SectionFig. 4. 14C Mild SteelFig. 4. 14B Mild Steel Tube
Reference
Grade A of IS 2062/Grade 2 or 3 of IS 9550IS 1161 — medium (see Note)1S 1239 (Port 1) — mediumGrade A of IS 2062Grade A of IS 2062Is 808GradeA of IS 2062IS 1239 (Part 1) — medium
Material INOTE— In caseof non-availability, 175 NB pipe maybe rolled and welded from 4 mm sheet conforming to Grade Aof 1S2062 keeping other dimensions as per IS 1I61.
Manufacturing toleranceto be * 0.5 unless otherwise specified.
All dimensions in millimetres.
FIG. 4.13 STAND— EDWP .
40
3.7 x45”
~50 NBPipe (medium)AS PER IS 1239 (Part 1)
4.1 4A Stand Pipe —Standard
(For SDWP, VLOM-65,VLOM-50)
3.1 x45”
111I
1I
11111
I
I
I: 1:1t
tII ;I 1I I1,I I
It.
IS 15500 (Part 4) :2004
L 230 I
4.14B Stand Pipe —EDWP
(For EDWP)
4 Holes 013< +0.5
1
w
~
4.14C Stand Flange
--l-%
‘i TO SUIT RADIUS-t
N
~ ‘k
OF STAND PIPE
:N
+
& [[~
to
m ENLARGED: VIEW - A
oN m*
‘J*40x40x6
&’M
( 7s1 .5
I ,
m to ,
0m
6!30
1-
I--==-l
4.14D Leg
!4IAI ~-------------------
II 1:
I
il- 4II To suit ID of 175 11II NB Pipe(medium) 1I., 1,
AT Xu----- —------- _-------JJ
4.1 4F Reducer Coller
1,Jndicatescritical dimensions.
Alternatedaslgn
4.14E Gusset
4.14G Spike
Manufacturing tolerance to be * 0.5 unless otherwise specified.
All dimensionsin miilimetres.
FIG.4.14 PARTSOF S_kANIJ
41
. . .. .... ..—-—
IS15500 (Part 4):2004
)’2
P G 1
[
654321
PartNo.
112111
No.off
Riser Pipe Holder — 32Tank Bottom Flange — 32GussetspoutTank Top FlangeTank Pipe
Description
& /5 d6
.
Fig. 4. 18FFig. 4.18EFig. 4. 18DFig. 4. 18CFig. 4. 18BFig. 4.18A
Reference
Mild SteelHR SectionMild SteelMS Tube 40 NBMild SteelMS Tube 150 NB
Grade A of IS 2062Grade A of IS 2062Grade A of IS 2062Medium, IS 1239 (Part 1)Grade A of IS 2062Medium, IS 1239 (Part 1)
1
Material
NOTES
1 Fillet size of weld at all places shall be 5 mm minimum, excepting spout where it shall not be less than 4 mm. Theinside welding of the tank pipe shall be given a sealing run.
2 One side of the coupling to be faced.
3 Sealing run on the top flange to be ground smooth.
4 Verticality of the riser pipe holder to be ensured during fabrication.
FIG, 4.15 WATER TANK — 32
(For SDWP & EDWP)
42
IS15500 (Part 4):2004
)’2
P G ,
654321
112111
C/3
Riser Pipe Holder — 50Tank Bottom Flange — 50GussetspoutTank Top FlangeTank Pipe
L/5 6
Fig. 4. 18HFig. 4. 18GFig. 4. 18DFig. 4.18CFig. 4. 18BFig.4.18A
Part No. Description ReferenceNo. off
Mild SteelHR SectionMild SteelMS Tube 40 NBMild SteelMS Tube 150 NB
Grade A of IS 2062Grade A of IS 2062Grade A of IS 2062Medium, IS 1239 (Part 1)Grade A of IS 2062Medium, IS 1239 (Part 1)
Material
NOTES
1 Fillet size of weld at all places shall be 5 mm minimum, exeepting spout where it shall not be less than 4 mm. Theinside welding of the tank pipe shall be given a sealing run.
2 One side of the corrpiing to be faced.
3 Sealing run on the top flange to be ground smooth.
4 Verticality of the riser pipe holder to be ensured during fabrication.
FIG. 4.16 WATERTANK— 50
43
IS 15500 (Part 4): 2004
02
6 1 Riser Pipe Holder — 65 Fig. 4. 18J Mild Steel Grade A of IS 20625 1 Tank Bottom Flange — 65 Fig. 4.181 HR Section Grade A of IS 20624 2 Gusset Fig. 4. 18D Mild Steel Grade A of IS 20623 1 spout Fig. 4. 18C MS Tube 40 NB Medium, IS 1239 (Part 1)2 1 Tank Top Flange Fig. 4. 18B Mild Steel Grade A of IS 20621 1 Tank Pipe Fig. 4.18A MS Tube”150 NB Medium, IS 1239 (Part 1)
Part No. Description Reference MaterialNo. off
NOTES1 Fillet size of weld at all placesshallbe 5 mm minimum, excepting spout where it shall not be less than 4 mm. The insidewelding of the tank pipe shall be given a sealing run.
2 One side of the coupling to be faced.
3 Sealing ron on the top flange to be ground smooth.
4 Verticality of the riser pipe holder to be ensured during fabrication.
FIG. 4.17 WATERTANK— 65
44
.
1
IS 15500 (Part 4) :2004
150 NBPIPE
I II I
1II
: I1I I
II I
,I
I
II
tI
II
I I I1
1I
-1I IJ
+ ‘+
Im1-
HOLE TO SUIT 4 NB\ PIPE (MEDIUM)
4.1 8A Tank Pipe
Weld
R12*1
250●
1254
●
P100 100
-i
‘ XH0LES,C313+?5
11A
1
I I “+6
4.18B Tank Top Flange
\i-=28092
*
[ : ~
------------------------------------------------1
.J
5+:5f‘ -—- —-— -—- —-— -—- —-
-----------------------------------;
+i;
g /
<; ** I1 : 40+:i I
1, PIPEOF NOMINALBORE40MMi
I
(MEDIUM):
i: ,1’
: ;t
u
-0
—
--4/
--t3=-!ID0*
ALTERNATEDESIGN
4.1 8D Gusset
Manufacturingtoleranceto be* 0.5 unlessotherwisespecified.
Alldimensions in millimetres.
FIG. 4.18 PARTSOFWATERTANK (Continued)
45
...——.-.——.— ,,--f--- ~- -’ -’ ..”.
“7
IS15500 (Part 4):2004
1-r
r .—%1 I
11+-4 Holes,013+85
)
J--\ I I #90 1- 90 ‘+
I ,,,,,-7,,vf.~.~....r.f.nI
i““L{
4.1 8F Riser Pipe Holder — 32(For SWDP & EDWP)
4.18E Tank Bottom Flanae — 32(For SWDP & EDW~)
CHF1.5X45”075f0.5 B&TH SIDES
l-- 4
4. 18G Riser Pipe Holder — 50
H+
I+
063
*
-. -—- _
4 Holes,013%5
L\ f 1 ,90 90
Jd
R12M230 4.1 8H Tank Bottom Flange — 50
115-i
‘+I +’
& ~078
0ho
[ :L _ , ;
a-—- -- ---
~mm 4 Holes,013 ‘$5
+
90 90 6r
~++4.181 Tank Bottom Flange — 65
CHF1.5X45”BOTHSIDES
1- 06S*0.5 +
Rp 24 (IS 554) ‘)
4.18J Riser Pipe Holder — 65
1)Indicates critical dimensions.
Manufacturing toleranceto be + 0.5-unlessotherwisespecified.
All dimensionsin millimetres.
FIG. 4.18 PARTSOFWATERTANK (Concluded)
46
[
u)0)
IS15500 (Part 4):2004
G
2 1 Steel Cone Fig. 4.20B Mild Steel Grade A of IS 20621 1 Cone Flange I Flg. 4.20A Mdd Steel I Grade A ot 1S2062
Part No. Description Reference MaterialNo. off I
FIG. 4.19 CONEPLATE
230
I I
A
I
t-0126
~
4.20A Cone Flange 4.20B Steel Cone
Manufacturingtolerance to be * 05 unlessotherwise specified.
All dimensionsin millimetres.
FIG. 4.20 PARTSOFCONEPLATE
47
IS 15500 (Part 4) :2004
HEX COUPLER HEX COUPLERM12x1.75 M12x1 .7550 LONG, 18 AIF 20 LONG, 18 A/F
1?
M12x1.751)
1, .— -— .— -— —- —- —- —J
1) 1)~ -r
30+11 28 -!- -
3000+:0r- +
NOTES1 Electro-galva~izing according to IS 1573 service grade No. 4.
2 The tolerance of threads shall conform to IS 14962(Part 3) class 6 g for bolts and 6H for nuts.
1) I ndi~ates ~ritjcal di~ensjons,
All dimensions in millimetres.
FIG. 4.21 CONNECTINGROD
STAINLESS STEEL, HEX COUPLERM12X1.75, 20 LONG, 18 AJF
..
STAINLESS STEEL, HEX COUPLERM12X1.75, 20 LONG, 18 A/F
--tkLd4’ -tK-@II’1)Indicates c~itjcal dimensions,
All dimensions in millimetres.
FIG. 4.22 PLUNGERROD — STANDARD
(For SDWP)
1}Indimtescritical dimensions.
All dimensiom$in millimetres.
FIG.4.23 PLUNGERROD — LONG(For EDWP, VLOM-65 & VLOM-50 )
48
-. .-. .
IS 15500 (Part 4) :2004
-0.02 ‘) ~oM12x1.751) 020-0.033 025 -o.aM 18&
o ? c ~–– ‘- ~’ 1
+.—. -—- —-— .— -—-
f
27?5 73$5 30:2 10M.2
147ti- 1
NOTE — Relief as per Type E of IS 3428 shall be provided.
-—-— -—-
86*1I
!
1,Indicates critical dimensions.
All dimensionsin millimetres.
FIG. 4.25 PUSHROD
Chf 1.5x45”both sides
I---==--l1)Indicates~ritic~dimensions.
All dimensions in millimetres.
FIG. 4.28 SOCKET— 32(For SDWP & EDWP)
1)Indicatesc~itic~di~ensions$
All dimensionsin millimetres.
FIG. 4.24 HANDLEAXE
021
t-l21?’
~T
u026
1)Indicatescriticald[menskms.
All dimensions in millimetres.
FIG. 4.26 BEARINGSPACER
Chf 1.5x45”both sides
h
Ill]c.-E
WI’068 min.* J
1)]ndicates~riti~aldimensions:
All dimensions in millimetres.
FIG. 4.29 SOCKET— 50(For VLOM-50)
49
--l-k=
1)Indicakscritical dimensions.
All dimensionsin millimetres.
FIG. 4.27 WASHER
Chf 1.5x45”both sides
064 min.9
‘)Indicates critical dimensions.
All dimensions in millimetrcs.
FIG. 4.30 SOCKET— 65(For VLOM-65)
/.
-— —.-...,. . .. ..— .....-”. -.. —
‘““
IS 15500 (Part 5) :2004
Indian Standard
DEEPWELL HANDPUMPS, COMPONENTS ANDSPECIAL TOOLS — SPECIFICATION
PART 5 CAST IRON COMPONENTS
1 SCOPE
1.1 This part specifies the requirements of cast ironcomponents used in the assembly of each type ofhandpump (SDWP, VLOM-65, VLOM-50 and EDWP)covered in this standard.
1.2 This part shall be read with Part 1. Stipulationsprovided therein, whichever relevant to the componentscovered in this part, shall apply.
2 CONSTRUCTION
2.1 The constructional details of different componentscovered in this part shall be as given in Fig. 5.1 to5.6.
2.2 The material and dimensions shall meet the relatedprerequisites given in 4 and 5 of Part 1.
2.3 The exterior surfaces of the cast iron componentsshall be given the treatment as mentioned in 6 ofPart 1.
3 TESTING
3.1 Group of each type of component covered in thispart shall be treated as a separate lot.
3.2 Test samples shall be drawn as per proceduredescribed in 9.3 of Part 1.
3.3 The critical dimensions of all the componentsselected as per 3.2 shall be checked for conformancewith the relevant figures given in this part.
3.4 Criteria for Conformity
3.4.1 The individual lot of components, as definedin 3.1, shall be considered conforming to therequirements of the standard, if the batch for theparticular lot selected according to 3.2 satisfy therequirements given in 3.4.2.
3.4.2 The number of components not meeting therequirements of a characteristic inspected under 3.3shall not exceed the corresponding acceptance numberas specified in IS 2500 (Part 1).
4 MARKING
The requirements given in 11.5.3 of Part 1 shall befollowed.
5 PACKING
The requirements of 12.1 and 12.2 of Part 1 shall apply.
50
IS15500 (Part 5):2004
R3
T7 I.
I
I
I
I
I
I
+1.5, 075.6 0
t
1=C$or-N
15X2Raisad
I
I1
1
I
11
tI
I!
R3+0.2
065.35 0
I G Z? (IS 2643)1)
2 Ribs. 3.5x2
1)Indicates critical dimensions.
All dimensionsin millimetres.
FIG. 5.1 CYLINDER BODY— STANDARD(For SDWP)
51
.. . . .
IS 15500 (Part 5): 2004
TR37
I G 24 (IS 2643) ‘)
=$40
bN
I
2 RIBS, 3.5x2
oppositeandraiaad
1
qz8
1- -i
‘)Indicates critical dimensions.
All dimensionsin millimetres.
FIG. 5.2 CYLINDERBODY — LONG
(For EDWP & VLOM-65)
52
.. . .
IS 15500 (Part 5): 2004
TR37
~<
I
I
11II
[
IIIIII
IQ I1
TI
s’
iI
I1
ttII
2 Ribs, 3x2
oppositeandraised
L- G 21 (IS2643)1)—- J
I
1)Indicates~riti~~ldi~~n~i~n~.
All dimensions in millimetres.
FIG. 5.3 CYLINDERBODY— VLOM-50
53
,. .,
&- ..———— --?---- -- -.
7~-”-” ,
IS 15500 (Part 5) :2004
Rp”l~ (IS 554) ‘)
I G 2] (IS 2643)1) I
+2 ‘)09009
1)Indicates critical dimensions.
All dimensions in mil]imetres.
FIG. 5.4 REDUCERCAP(For SDWP & EDWP)
54
. ....
1
IS15500 (Part 5):2004
FTTl
ta-- 1—-.
. VA
I%“
y<! 067 ncI
v
II &-r
p I-. 1
1 WA+-I
G 2! (IS 2643) 1) I
G 2? (IS 2643)’)
RI) 2 (IS 554)1)
5.5A Upper Cap — VLOM-65 5.5B Bottom Cap — VLOM-65
1)[n~i@~~~~iti~~lf]~~n~i~~~,
All dimensionsin millimetres.
FIG. 5.5 CYLINDERCAPS— VLOM-65(For SDWP & EDWP)
55
‘... -
IS 15500 (Part 5): 2004
x-x Y-Y
5.6A Upper Cap — VLOM-50 5.6B Bottom Cap — VLOM-50
1,Itldicates critical dimensions.
All dimensionsin millimetres.
FIG. 5.6 CYLINDERCAPS— VLOM-50
56 I
..
1
IS 15500 (Part 6): 2004
Indian Standard
DEEPWELL HANDPUMPS, COMPONENTS ANDSPECIAL TOOLS — SPECIFICATION
PART 6 BRASS/BRONZE COMPONENTS
1 SCOPE
1.1 This part specifies the requirements of brass andleaded-tin-bronze components used in the assemblyof each type of handpump (SDWP, VLOM-65, VLOM-50 and EDWP) covered in this standard.
1.2 This part shall be read with Part 1. The stipulationsprovided therein, whichever relevant to the componentscovered in this part shall apply.
2 CONSTRUCTION
2.1 The constructional details of different componentscovered in this part shall be as given in Fig. 6.1 to 6.16.
2.2 The material and dimensions shall meet the relatedprerequisites given in 4 and 5 of Part 1.
3 TESTING
3.1 Group of each type of component covered in thispart shall be treated as a separate lot.
3.2 Test samples shall be drawn as per proceduredescribed in 9.3 of Part 1.
3.3 The critical dimensions of all the componentsselected as per 3.2 shall be checked for conformancewith the relevant figures given in this part.
3.4 Criteria for Conformity
3.4.1 The individual lot of components, as definedin 3.1, shall be considered conforming to therequirements of the standard, if the batch for theparticular lot selected according to 3.2 satisfy therequirements given in 3,4.2.
3.4.2 The number of components not meeting therequirements of a characteristic inspected under 3.3shall not exceed the corresponding acceptance numberas specified in IS 2500 (Part 1).
4 MARKING
The requirements given in 11.5.4 of Part 1 shall befollowed.
5 PACKING
The requirements of 12.1 and 12.2 of Part 1 shall apply.
57
,., .
IS15500 (Part 6):2004
6.1A Brass Liner — Short(For SDWP)
l--=--l6.1 B Brass Liner — Long(For EDWP & VLOM-65)
6.1 C Brass Liner — VLOM-50(For VLOM-50)
‘) Indicates critical dimensions.
All dimensions in millimetres.
FIG. 6.1 BRASSLINER
IS15500 (Part 6):2004
M19v1’7K ‘)*W,, a.a, .,.. II II +1
Saction at XX44
x
NOTE — Section 18 A/F can be at any location.
I) Indicates critical dimensions.
All dimensionsin millimetres.
FIG. 6.2 PLUNGERYOKE BODY(For SDWP, EDWP & VLOM-65)
06&k0.3’)b 4
1)
042%’2 1,3.5M.1])3.5 1- -1
I) ]ndicatescritical dimensions.
All dimensionsin millimetres.
FIG. 6.4 BUCKETSPACER— STANDARII(For SDWP, EDWP & VLOM-65)
4+:2
L
&3+; 3+;
3+:
023.5%’5
1,Indicates critical dimensions.
All dimensionsin millimetres.
FIG. 6.3 UPPERVALVE(For SDWP, EDWP & VLOM-65)
3.51)
a60io.3
050+!’8.
I
L R5M.5
‘) Indicates critical dimensions.
All dimensionsin millimetres.
FIG.6.5 BUCKET SPACER — LOWER
(For EDWP)
59
— —.-. . .. —.——,
.‘-IS 15500 (Part 6): 2004
G Id B (IS 2643)1)
m
I
I
6.5*0.5
F
III
I
l=kE_l =)
6.5M.5
G 1AB (IS 2643)’)
I
I
II
II
Ii
II
F’ I---l-l
5*0.5 S*O:5
1)Indicates~ritjcaldi~~n~i~n~.
All dimensionsin millimetres.
FIG. 6.6 FOLLOWER — SDWP
I*060*0.3 1)
r-w--l
ii
1!
l_t037.6t0.5
5*0.5 5*0.5
1)Indicatescriticaldimen~ion~,
Alldimensionsin millimetres.
FIG. 6.7 FOLLOWER— EDWP
60
IS 15500 (Part 6) :2004
6.5*0.5
050k0.5
060+0.5
—
N(3TE— 2x45”Chamfer at knuckle thread end and weak threadto be removed.
1)[ndicate~ ~riti~al dimen~ion~.
All dimensions in millimetres.
FIG. 6.8 FOLLOWER— VLOM-65
+1o
+)
H--=--l041+t5
-1R2—
1)Indicates critical dimensions.
All dimensions in millimetres.
FIG. 6.9 CHECKVALVE— STANDARD(For SDWP & EDWP)
61
,-
IS15500 (Part 6):2004
-+1--
048 -;.2t- -1
4:.1
f-f
4.!.1
R3—
d.
All dimensions in millimetres.
FIG. 6.10 CHECKVALVE— VLOM-65
1)
=0
‘) Indicatescritical dimensions.
All dimensionsin millimetres.
FIG. 6.11 RUBBERSEATRETAINER(For SDWP & EDWP)
m1)Indicates critical dimensions.
All dimensions in millimetres.
FIG. 6.12 CHECKVALVE SEAT— STAN~AR~(For SDWP & EDWP)
I
“{..”,
62
------- .. . . . ---- .Is 155uu (l-’art 6) : wu4
0
—
—
A-A
6 HOLES,06 EQUALLYI / SPACEDAT PCD 22
TA
A--i I1= 052+i’3
NOTE— 2x45” Chamferat knucle thread end andweak thread to be removed.
1)]ndicatescritical dimensions.
All dimensionsin millimetres,
FIG. 6.13 CHECK VALVE — VLOM-65
1) Indicates critical di~ensions.
All dimensionsin millimetres.
FIG. 6.14 CAGE(For VLOM-65)
63
r-
7‘1
IS 15500 (Part 6): 2004
038i0.2
M12x1.751) _FOR 19NFI 1- -1 II
L. 047$s I
1)indicates critical dimensions.
All dimensions in millimetres.
ALLSHARPEDGESOFTHISWINDOW(ON BOTHTHE SIDES)SHALLBEROUNDEDOFFPROPERLY.
25i0.31)1-
Sectional view at XX
FIG. 6.15 PLUNGERVALVE BODY— VLOM-50
64
IS 15500 (Part 6): 2004
g 1 “//,
L 048*0.3 A
25M.3 1)i-
1~ 6 Nos,EQUlDlSTAt4T
06 HOLES AT PCD20ALTERNATEPIAN VIEW
ALLSHARPEDGESOFTHISWINDOW(ONBOTHTHESIDES)SHALLSEPROPERLYROUNDEDOFF.
‘) Indicatescritical dimensions.
x-x
All dimensionsin millimetres.
FIG. 6.16 CHECKVALVE BODY— VLOM-50
65
,>
IS15500 (Part 7):2004
Indian Standard
DEEPWELL HANDPUMPS, COMPONENTS ANDSPECIAL TOOLS — SPECIFICATION
PART 7 RUBBER COMPONENTS
1 SCOPE
1.1 This part specifies the requirements of rubbercomponents used in the assembly of each type ofhandpump (SDWP, VLOM-65, VLOM-50 and EDWP)covered in this standard.
1.2 This part shall be read with Part 1. Stipulationsprovided therein, whichever relevant to the componentscovered in this part, shall apply.
2 CONSTRUCTION
2.1 The constructional details of different componentscovered in this part shall be as given in Fig. 7.1to 7.15.
2.2 The material and dimensions shall meet the relatedprerequisites given in 4 and 5 of Part 1.
3 TESTING
3.1 Group of each type of component covered in thispart shall be treated as a separate lot.
3.2 Test samples shall be drawn as per proceduredescribed in 9.3 of Part 1.
3.3 The critical dimensions and hardness of all thecomponents selected as per 3.2 shall be checked forconformance with the relevant figures given in thispart.
3.4 Criteria for Conformity
3.4.1 The individual lot of components, as definedin 3.1, shall be considered conforming to therequirements of the standard, if the batch for theparticular lot selected according to 3.2 satisfy therequirements given in 3.4.2.
3.4.2 The number of components not meeting therequirements of a characteristic inspected under 3.3shall not exceed the corresponding acceptance numberas specified in IS 2500 (Part 1).
4 MARKING
The requirements given in 11.5.5 of Part 1 shall befollowed.
5 PACKING
The requirements of 12.1 of Part 1 shall apply.
“
66
I
-. ._ _
IS 15500 (Part 7) :2004
1)
063.3 ‘;3P 1 W
I I
L
1- 060.5 NOm. --l
Shore hardness 81)~~on scale A.
1)]ndicates critical dimensions.
All dimensionsin millimetres,
FIG. 7.1 PUMPBUCKET— STANDARD
(For SDWP, EDWP & VLOM-65)
+02 1)
r.050 O“
041*0.1 1) ~ ‘;24
1-10.:,1
Shore hardness SO~~on scale A.
1)Indicates critical dimensions.
All dimensions in millimetres,
FIG. 7.2 PUMP BUCKET — VLOM-50
077 ‘~L d 1)
054.5 :.5 4+/Jr I -1 r{ ,11 ‘7
Shore hardness W: on scale A.
‘)Indicates critical dimensions
All dimensions in millimetres.
FIG. 7.3 SEALINGRING— STANDARD(For SDWP & EDWP)
077 ‘;1- -1 ,.
Shore hardness So~~on scale A.
1)[Ildicates critical dimensions
All dimensions in millimetres.
FIG. 7.4 SEALING RING— VLOM-65
67
,r
‘“”7
IS15500 (Part 7):2004
Serratiorrsorr~ I
1)
4+A
r
Shorehardness 60~~on scdle A.
l) Indicates criti~al dimensions.
Ail dimensions in millimetres.
FIG. 7.5 SEALINGRING— VLOM-50
1, ~19.5&+,,$;)
WAi “’+
Shore hardness 80~ on scale A.
l) Indi~ates~riticaI dimen~ions.
All dimensions in millimetres.
FIG. 7.6 UPPERVALVE SEATING(For SDWP, EDWP & VLOM-65)
1)
4.84.2
+Shore hardness 80~ on scale A.
1)Indicatescritical dimensions.
All dimensions in millimetres.
FIG. 7.7 LOWERVALVE SEATING— STANDARD(For SDWP & EDWP)
046.5$5l-= 1
Shore hardness so~~on scale A.
1)]ndicatescriticaldim~nsion~.
All dimensions in millimehes.
FIG. 7.8 LOWERVALVE SEATING— VLOM-65
68
IS15500 (Part 7):2004
A!Y
FY-1I
91Q.2
Zo*30” 3x45”
! i
I.A@!-lShore hardness so~ on scale A.
1)Indicates ~~iti~~ldi~~n~ions.
All dimensions in millimetres.
FIG. 7.9 BOBBIN(For VLOM-50)
+050
-1 04*0.1
Shore hardnessc@: onscaleA.
All dimensions in millimetsw..
FIG. 7.10 O-RING— VLOM-65
038.8b >04*0. 1
I—.— *—. —
I /
Shore hardness 60~ on scale A.
All dimensions in millimetres.
FIG. 7.11 O-RING—VLOM-50
0130
‘-K
Shore hardnessS03 onscaleA.
All dimensionsin millimetres.
FIG. 7.12 RUBBERCONE— VLOM-65
0130
t- 1
Shorehardnessso: onscaleA.
All dimensionsin millimetres.
FIG. 7.13 RUBBERCONE— VLOM-50
69
.. .
lS15500 (Part 7):2004
L-A
w Imm DEEP MARKS ONLY(ON BOTH THE FACES)
Inm
A-A
NOTES1 Only one centralizer to be provided resting against first pipe-joint from the top.
2 The above centralizer is suitable for 150 NB casing pipe. U maybe trimmed at R60 marks for use with 125 NB casing pipe.
Shore hardness 80~~on scale A.
Manufacturing tolerance to be +0.5 unless otherwise specified.
All dimensions in millimetres.
FIG. 7.14 PIPE CENTRALIZER— VLOM-65
70
.
IS15500 (Part 7):2004
Imm DEEP MARKS ONLY(ON BOTH THE FACES)
‘-?/
A-A
NOTES
1 Only one centralizer to be provided resting against first pipe-joint from the top.
2 The above centralizer is suitable for 150NB casing pipe. It may be trimmed at R60 and R47.5 marks for use with casing pipeof 125ahd 100 NB respectively. .
Shore hardness 80~~on scale A.
Manufacturing toleranceto be *0.5 uniess otherwise specified.
“-j
All dimensions in millimetres.
FIG.7.15 PIPECENTRALIZER— VLOM-50
IS 15500 (Part 8): 2004
Indian Standard
DEEPWELL HANDPUMPS, COMPONENTS ANDSPECIAL TOOLS — SPECIFICATION
PART 8 SPECIAL TOOLS
1 SCOPE
1.1 This part specifies the requirements of special toolsfor use in installation and maintenance of handpumpscovered in this standard.
1.2 The tools have been arranged in three groups:
a) Group 1: (Fig. 8.1.1 to 8.1.10)Tools common for all the handpumps.
b) Group 2: (Fig. 8.2.1 to 8.2.8)Tools specific to SDWP and EDWP.
c) Group 3: (Fig. 8.3.1 to 8.3.7)Tools specific to VLOM-50 and VLOM-65.
1.3 The quantity of different tools, with the referenceof their respective figures, comprising each set of specialtools required for installation and/or maintenance of aparticular type of handpump is listed in Annex D.
1.4 Heavy-duty clamp and self-locking clamp coveredin group 2 are suited up to 45 m depth application.Alternate pipe clamp arrangements may be used forapplication beyond 45 m.
1.5 This part shall be read with Part 1. Stipulationsprovided therein, whichever relevant to the specialtools covered in this part, shall apply.
2 NOMENCLATURE
2.1 Water Tank Lifter
Required for the handling of the water tank duringassembly and dismantling of the pump.
2.2 Pipe Lifting Spanner
Required for lifting or lowering riser pipes.
2.3 Axle Punch
Required to drive the handle axle out of the headassembly.
2.4 Crank Spanner
Required for fastening of M 12 and MIO bolts and nutsspecially the chain bolt.
2.5 Connecting Rod Lifter
Required to facilitate lowering or lifting of theconnecting rods.
2.6 Bearing Pressing Tool
Required for pressing the bearings in the bearinghousing.
2.7 Chain Coupling Supporting Tool
Required to facilitate the disconnection of the chainfrom the handle.
2.8 Rod Coupler Spanner
Required for easy fitment of the connecting rods.
2.9 Heavy Duty Clamp
Required for clamping the riser pipe. It works on slidingjaw system.
2.10 Self-Locking Clamp
An alternate arrangement for clamping of the riser pipe.It grips the pipe as soon as its handle is released.
2.11 Connecting Rod Vice
Required to clamp the connecting rod.
2.12 Check Valve Puller
Required to facilitate extraction of the check valve inVLOM handpump.
2.13 Tool BOX
A steel box to keep all above tools except the onesunder serial 2.1, 2.2, 2.9 and 2.10.
3 CONSTRUCTION
3.1 The constructional details of different tools coveredin this part shall be as given in Fig. 8.1.1 to 8.1.10,Fig. 8.2.1 to 8.2.8 and Fig. 8.3.1 to 8.3.7.
3.2 The material and dimensions shall meet the relatedprerequisites given in 4 and 5 of Part 1.
3.3 The tool box shall be made of 1 mm nominal thickCRCA steel sheet (see IS 513), with the overalldimensions given below:
Length 440 mm
Width 320 mm
Height llOmm
IL
3.3.1 The hinged lid shall be provided with suitablearrangement for putting a lock.
4 ANTI-CORROSIVE TREATMENT
4.1 Electrogalvanizing
Unless otherwise specified, all the tools andcomponents thereof, except the axle pin (Fig. 8.2.7C)and the spring (Fig. 8.2.7F), shall be electroplated asper service grade No. 3 of IS 1573 and passivated inaccordance with IS 9839. Bolts and nuts shall beelectroplated in conformance with IS 1367 (Part 11).
4.2 Painting
4.2.1 All the internal surfaces?where electrogalvanizingis not possible, shall be protected with a coat of redoxide primer conforming to IS 2074.
4.2.2 The box shall be given the following anti-corrosive treatment:
a) One coat of red oxide primer conforming toIS 2074.
b) Two coats of synthetic enamel paintconforming to IS 2932.
5 TESTING
5.1-For the purpose of testing, group of each type oftool covered in this part shall be treated as a separatelot.
5.2 Test samples shall be drawn as per proceduredescribed in 9.3 of Part 1.
5.3 The tools selected as per 5.2 shall be subjected tothe following checks:
5.3.1 All the tools shall be examined for finish,workmanship and visual defects.
5.3.2 The base plates of the clamps and/or vice shallbe reasonably flat to provide proper matching of holesto ensure unrestricted insertion of bolts when fitted onrespective flanges of the handpump.
5.3.3 The movement of the screws of the heavy dutyclamp and the connecting rod vice shall be easy withoutundue slackness or resistance throughout the opening.Proper alignment of their jaws shall be ensured.
5.3.4 In case of the self-locking clamp:
a) The jaws shall have free movement whenoperated with handle and shall close instantlywhen handle is released,
b) The handle shall not have excessive play bothin vertical and horizontal direction whenchecked before application of force to openthe jaws,
c)
d)
IS 15500 (Part 8) :2004
The jaws should be properly aligned to provideproper and firm gripping of the pipe, and
One clamp, after fixing suitably, shall beoperated at least 100 times. The difference inlength of the spring measured before and afterthe test shall not be more than 0.5 mm.
5.3.5 In case of the connecting rod vice:
a)
b)
The gap between the locking block and thefixed block to be checked for dimension. Itshall be centrally placed with respect to theslot in the base plate, and
The lock plate shall have free movement.
5.3.6 Two samples out of the batch selected shall bechecked for dimensional and other requirements givenin respective figures.
5.3.6.1 In case of assembly, all the components shallbe dismantled and tested likewise.
5.3.7 Clamping Test
5.3.7.1 For the testing of the heavy duty clamp and theself-locking clamp, a solid or hollow mandrel ofsuitable length having following outer diameter andsmooth surface shall be gripped in the jaws. An axialload of 500 kgf shall be applied on the mandrel bysuitable arrangement. The mandrel shall not slip.
Mandrel size
For 32 mm pipe clamp :42 mm outer dia.
For 50 mm pipe clamp: 60 mm outer dia.
For 65 mm pipe clamp :75 mm outer dia.
5.3.7.2 A similar test shall be done on the connectingrod vice by using 12 mm diameter drawn bar and aload of 200 kgf. There shall be no slippage of the bar.
5.4 Criteria for Conformity
5.4.1 The individual lot of components, as definedin 5.1, shall be considered conforming to therequirements of the standard, if the batch for theparticular lot selected according to 5.2 satisfies therequirements given in 5.4.2.
5.4.2 The number of tools not meeting the requirementsof the characteristics inspected under 5.3 does notexceed the corresponding acceptance number asspecified in IS 2500 (Part 1).,
6 MARKING
Each tool shall have clear and legible steel punchimpression of manufacturer’s identification mark.
7 PACKING
As agreed to between the supplier and the purchaser.
73
,.
IS15500 (Part 8):2004
Y1
I\ I r“
o-1
I \ %.—. —._ -— 1-
‘E ; IiifT-
. .
-1
1-
T8171615141312111
Part No.No. off
n—-
Locking Nut M8Hex Bolt M8 x 20Rod Vice Base AssemblySpecial Bolt M8 x 40Movable JawLocking PlateThreaded ShaftHandle
Description
Std 02Std 06Fig. 8.I.2FFig. 8.I.2EFig. 8.1.2DFig. 8. 1.2CFig. 8. 1.2BFig. 8.1.2A
Reference
SteelSteelMild SteelMild SteelMild SteelMild SteelMild SteelMild Steel
IS 1363(Part 3)IS 1363(Part 1)GradeA of IS 2062GradeA of IS 2062GradeA of IS 2062GradeA of 1S2062GradeA of IS 2062GradeA of IS 2062
tiaterial
All dimensions in millimetres.
FIG. 8.1.1 CONNECTINGROD VICE
74
—
[
4
[-,
M12
t
T
0’2
-f-
&
I
I
I
-L
-t
012.2+:3
IS 15500 (Part 8) :2004
SclUrethread 020X 4
E‘‘1-- : ~— ‘“::-+i---
r---t
4S - - ‘- — ‘—-—- -—- —-— -—-CD5 .
i-h i-u8.5
I-=---J
Hex Nut
r
M12x1.75
06.5+t2
Hex Nut M12xI .75 ~
SEALWELD NUTATONEENDANDOTHEREND-PUNCHLOCKEDAFTERTIGHTENINGTHENUTFULLYWHENASSEMBLEDINVICE.
8.1 .2A Handle
R9
K
—
<t
—
8.1 .2B Threaded Shafl
.
—
,.
,.
—
8.1 .2C Locking Plate
6
SURFACE PUNCHED
—----7P ?
IlEt!3t.. m/ \
\ 1 Im
II I II
L--L25
CARBURISE AND HARDENEDTO 40 TO 45 HRC
8.1 .2D Movable Jaw
8.1 .2E Special Bolt
+0.2‘o
All dimensions in millimetres.
FIG. 8.1.2 ROD VICE PARTS (Continued)
75
7
IS15500 (Part 8):2004
h
oN
A, I ,L
UJ u65 65
I4
II A
I
N
&
1m
1 !\
I
6.5+15~
— - ~
+0.513 0 I
I
@
@ ~
* Faces to be flame hardened 30-50 RC *
-+-
+
—-— - —-
7 1 Locking Block Fig. 8.1.3G Mild Steel Grade A of IS 20626 1 Fixed Block Fig. 8.1.3F Mild Steel Grade A $1S 20625 I Carrying Handle Fig. 8.1.3E Mild Steel Grade A of IS 20624 1 Supporting Block Fig. 8.1.3D MiId Steel Grade A of IS 20623 1 Fixed Nut Fig. 8.1.3C Mild Steel Grade A of IS 20622 2 ~ase Plate Lug Fig. 8.1.3B Mild Steel Grade A of IS 20621 1 Base Plate Fig.8.1 .3A Mild Steel Grade A of IS 2062
Part No. Description Reference MaterialNo. off
8.1 .2F Rod Vice Base Assembly
All dimensions in millimetres.
FIG. 8.1.2 ROD VICE PARTS(Concluded)
76
1, 1. II
Ill 1111 Ill
I I I :’ ‘+
03
t
125 125I
●
1
I R28
*---------
-M--4 Holes, 014%’5
t
F-+-
+
~
8.1 .3A Base Plate
+i$ii!IF-1
b1X45*
h5.5
J
I013.5
1X45*u
011
SQ. THREADS 020X4
PI--------------~--------I
I-—-— - —-
1t II I
=
R12tl
—-IllL-@--
8.1 .3B Base Plate Lug 8.1 .3C Fixed Nut
All dimensions in millimetres.
FIG. 8.1.3 ROD VICE BASEASSEMBLYPARTS(Continued)
.
‘7
IS15500 (Part 8):2004
10*0.2 __ ,
F- ‘-: --- ;~)
55
8l—
L V-PORTIONTO BESURFACEPUNCHEDAND FlAMEHARDENEDTO 30A0 Rc. FIAMEHARDENINGTO BEDONEAFTERWELDINGWITH THE BASEPIATE.
L==-8.1 .3D Supporting Block
ca
.
ElL--J
8. 1.3F Fixed Block
K--iifi~ 27.5 =] I 10*0.2
8.1 .3G Locking Block
All dimensions in millimetres,
—.
-
—
_
Q/./–../
“/’”/
I
.
8.1 .03E Carrying Handle
FIG. 8.1.3 ROD VICE BASE ASSEMBLYPARTS (Concluded)
78
IS 15500 (Part 8) :2004
1 1 Axle Punch Mild Steel Grade A of IS 2062
Part No. Description MaterialNo. off
Carburized and hardened to 30-40 HRC.
Alldimensions in millimetres.
FIG. 8.1.4 AXLE PUNCH
5oi28
3,.—.—--I
--w-L-~A
u14kl
A-A
—
I 1 I I I Chain Coupler Supporting Tool I Mild Steel I Grade A of IS 2062 I
Part No. Description I MaterialNo. off I
—
1
All dimensions in millimetres.
FIG. 8.1.5 CHAIN COUPLERSUPPORTINGTOOL
79
IS15500 (Part 8):2004
STANDARD FORGED SPANNERSOCKET FOR HEX. M12 NUT
\ P2
/
II
I‘d
1
L
I
II
It
It
I1
II
38*2 15*0.5I
3
-A -—-— .—
‘@E?/ STANDARD FORGED SPANNER
SOCKET FOR HEX. M1O NUT
P
1
016
M.S. ROD WITH ENDS FORGED ORMILLED TO 13MM SQ. X 15MM
r
E321
PartNo.
1 Socket Spanner (Ml O) SteeI IS 20301 Socket Spanner (M12) Steel IS 20301 Rod Mild Steel Grade A of IS 2062
1
No. Description Materialoff
.
1
All dimensions in millimetres.
FIG. 8.1.6 CRANK SPANNER
80
IS15500 (Part 8):2004
250*3
WELDED& GROUND- ,08,
I
‘%
012
II
!
I
I
!
\
I
9EiiE7-----‘k 3 3
)-J-3/c2
HEX. COUPLER M12X50 LONG18 AIF, STRESS RELIEVED
I 311 I T-Rod I Mild SteeI I Grade AofIS 2062 I2 1 Hexagonal Coupler Mild Steel Grade A of 1S20621 I Rod Mild Steel Grade A of IS 2062
Part No. Description MaterialNo. off
All dimensionsin millimetres.
FIG. 8.1.7 CONNECTINGROD LIFTER
81
IS15500 (Part 8):2004
I
2X50 LONGLIEVED
~ 32 N. B. PIPE (MEDIUM)IS 1239(PART 1)1990
2 1 Hexagonal Coupler Mild Steel Grade A of IS 2062
1 1 Pipe Mild Steel IS 1239 (Part 1)
Part No. Description MaterialNo. off
NOTE— Insidesurfaceof pipe shall be protectedwith Red Oxide Primer.
All dimensions in millimetres.
FIG. 8.1.8 CONNECTINGROD LIFTER(ALTERNATEDESIGN)
82
,.
IS15500 (Part 8):2004
-JL’J=\
z41312111
Part No.No. Off
Hex. Nut, M20 x 2.5SpacerFixed CouplerShaft
Description
SteelMild SteelMild SteelMild Steel
IS 1363 (Part 3)Grade A of IS 2062Grade A of IS 2062Grade A of IS 2062
Waterial
All dimensions in mi[limetres.
FIG. 8.1.9 BEARINGPRESSINGTOOL
83
IS15500 (Part 8):2004
1-65ti 15
I 1I J
E ‘0 .—-— -—-— -—-— -—-
P1 - ‘--;+=
80i2- -
40*1
2 1 Rod Mild Steel Grade A of IS 20621 1 Plate Mild Steel Grade A of IS 2062
Part No. Description MaterialNo. off
All dimensions in millimetres. .
FIG. 8.1.10 ROD COUPLERSPANNER
84
*
IS 15500 (Part 8) :2004
-m
3483
4
t I 1II
II
\ I/
/ :
/
#
#
//
,/
I
II
I
3
R 1: (IS 554)
TO BE MADE OUT 0~ROD OR SEAMLESS PIPE
016.5 THROUGH HOLE
I 21 Pipe, 32 NB Steel IS 1239 (Part 1) — Medium11 Pipe Coupler Mild Steel Grade A of IS 2062
Part No. Description MaterialNo. off
All dimensions in millimetres.
FIG. 8.2.1 WATERTANK LIFTER -
85
b
1S15500 (Part 8):2004
t-y--l
AND GROUND
I
!+-~ --0m --- -— .—-— -—- _-— -
-.4242+/ I h
630*3. .
795*4F
Y
25 NB PIPE (HEAVY)
‘ ‘7
------- ------------------ -------------- 1-1-—-L- —- —-— -—- —
_- _----p ------------------- --------------L
5
Q2
R65
A
% _-—mC9
54321
Pm-tNo.
I1111
No.off
End PlugPipe, 25 NBSplit RoadHook Plate‘U’ Plate
Description
I I 70*1 I Itt“
.-—. -1 I
1- 135*1 -1
4
—“[
t
Mild SteelMild SteelMild SteelMild SteelMild Steel
Grade A of IS 2062IS 1239 (Part 1)— HeavyGrade A of IS 2062Grade A of IS 2062Grade A of IS 2062
Material
All dimensions in millimetres.
FIG. 8.2.2 PIPE LIFTINGSPANNER
86
IS15500 (Part 8):2004
\
--L.
III
b A, ,1’1 I I
I I
7 2 Hex. Bolt MS x 30 Std 07 Steel IS 1363 (Part 1)6 2 Hexagon Socket Head Std 08 Steel 1S 2269
Cap Screw MIO x 255 1 Clamp Base Assembly Fig. 8.2.4E Mild Steel Grade A of IS 20624 1 Handle Fig. 8.2.4D Mild Steel Grade A of IS 20623 1 Threaded Shafi Fig. 8.2.4C Mild Steel Grade A of IS 20622 1 Fixed Jaw Fig. 8.2.4B Mild Steel Grade A of IS 20621 1 Movable Jaw Fig. 8.2.4A Mild Steel GradeA of IS 2062
Part No. Description Reference M;terialNo. off
NOTE— Thisclampissuitedup to 45 m depthapplication.Alternativepipe clamparrangementsmaybe usedfor application beyond45 m.
All dimensions in millimetres.
FIG. 8.2.3 HEAVY DUTY CLAMP
87
J’-
1IS15500 (Part 8):2004
I IT-Ti ‘ d ‘
T-T;1 1 1; i
,9 1,
k
,1 IIJ 1, ,1 II q,1 1, ,-- ., ,1 1, N,1 ,8 1, N,, 8 ;: I,1 It,
1+ -t- +1
j’\’ !] 1-- —- -1- -1- - — --— — -
j ,;;
I ~lj
I
.&$+” ‘~-] ‘-t- 7 +?$$$’ !
ft
I
1 t-23*0.3 M8 X 30 DEEP
12 I/’ t 12 -
47i0.25 47*0.25r——
CARBURISEDANDHARDENEDTO4@t5HRC
8.2.4A Movable Jaw
M1OX1.5
1- 47i0.25 / 47h0.25
/
I~ SURFACE PUNCHED
CARBURISEDANDHARDENEDTO4M5 HRC
8.2.40 Fixed Jaw
Sq.Thread26x4*I
1 r t tIll IIt ,i I ●
%Q !I Ii 1
Y L t “~~ “ ‘- z
=:--L-AA—. —-- — -—.—- —-— —-— -—-— -— --Ns
1, :
38 10
+ !I
R5(Rootdia 15) 5
180~2
8.2.4C Threaded Shafi
30W3 4 HEX NUT M16X2~ BE PUNCHEDLOCKED
. —-— -—- —.— - —-— -—- —-— -— -- AFTERASSEMBLYIN THECLAMP.
HEX NUT M16X2TO BE SEALWELD
8.2.4D Handle
All dimensions in millimetres.
FIG. 8.2.4 HEAVY DUTY CLAMPPARTS (Continued)
88
7
IS 15500 (Part
— I 1 L
,*X!====*S
--- 7=. ‘—I
— -
I
.— - —
-.m===-===.
b I A I
Ill /‘\\ I
Ill /’ Ill
I.
I
d /-1
= =.
A i / A
- ‘-:;+, {’:’’<’’”--:’ ~$~:::”t);~1-;\ G--1 *--
---- I,.
------------- 1*.2 //’-- ‘.,
1- /
: :- P ‘: ‘V - : 7 :
\ ‘ 25-- ft I \\
1’ !s -------I -------
-—- . —- —- l-—J--+-——— ‘—- -—
t 1 --------------\\ 1’--- , I
t’
J---- “\\,f’
45 I
+ +
5--
a .I--
8): 2004
5 1 Carrying Handle Fig. 8.2.5E Mild Steel Grade A of 1S20624 I Guide Plate Fig. 8.2.5D Mild Steel Grade A of IS 20623 1 Supporting Block Fig. 8.2.5C Mild Steel Grade A of IS 20622 1 Side Plate Fig. 8.2.5B Mild Steel Grade A of 1S20621 1 Base Plate Fig. 8.2.5A Mild Steel Grade A of IS 2062
Part No. Description Reference MaterialNo. off
8.2.4E Clamp Base Assembly
AH dimensions in millimetres,
FIG. 8.2.4 HEAVY DUTY CLAMPPARTS (Conclude~
89
,.
IS15500 (Part 8):2004
%
I \ I —I 1 1
I /’ I I ‘\
I [
11;
1 co
/’ 1I
‘\1,;
—
140 140 .
/ >
I
-+-
1
‘.‘\\
\!
1’i’i.—. — -— 1-It\\
R6”\ It\
3 HOLES 014’” 60+;
.F ‘
I 9
—. _—
“\\\I1II
-~- —-—-— -—-1I,
32 160- 4
R12
8.2.5A Base Plate
70 70
95●
8.2.5B Side Plate
All dimensionsin millimetres.
FIG. 8.2.5 CLAMPBASE ASSEMBLYPARTS (Continued)
—
1(
—
I{
16
t-1
—-.—
1Chf 5
,
90
IS15500 (Part 8):2004
115 d +115 9
Y
18x45”
-I.-I10
l-=--l w230*2
I1
I I I
i
I
~===== =====--1 ~-. ._;
I
--t— — A-— --
Jk1
-_JL- -1 I
I
L
t
_= ==== -===
I—
—
‘1.-=‘I J
I 2Z2L?J8.2.5C Supporting Block
8.2.5D Guide Plate 8.2.5E Carrying Handle
All dimensionsin millimetres.
FIG. 8,2.5 CLAMPBASE ASSEMBLYPARTS (Concluded)
IS15500 (Part 8):2004
11 1 Bolt M12 x 30 long Std 11 Steel IS 1364 (Part l)— Gr 10.910 1 Base Assembly Fig. 8.2.7J Mild Steel Grade A of IS 20629 1 Protection Cover Fig. 8.2.71 Mild Steel Grade A of IS 20628 1 Spring Retainer Fig. 8.2.7H Mild Steel Grade A of IS 20627 2 Lifting Block Fig. 8.2.7G Mild Steel Grade A of IS 20626 1 Spring Fig. 8.2.7F Spring Steel IS 4454 (Part 1)5 2 Link Plate Fig. 8.2.7E Mild Steel Grade A of IS 20624 2 Split Pin Fig. 8.2.7D Steel Is 5493 1 Axle Pin Fig. 8.2.7C Carbon Steel 40 C8 of 1Ss5172 1 Left Hand Jaw Fig. 8.2.7B Mild Steel Grade A of IS 20621 1 Right Hand Jaw Fig. 8,2.7A Mild Steel Grade A of IS 2062
Part No. Description Reference MaterialNo. off
NOTE — This clamp is suited up to 45 m depth application. Alternative pipe clamp arrangements may beused for application beyond 45 m.
All dimensions in millimetres.
FIG. 8.2.6 SELF-LOCKINGCLAMP
92
IS15500 (Part 8):2004
3 0, 110
~1’w
I
8.2.7A Right Hand Jaw
12.5
P49t0.2 36 .r 3.:.5
8.2.7B Left Hand Jaw
@ Surface hardened to 30-50 HRC.
All dimensions in millimetres.
FIG. 8.2.7 SELF-LOCKINGCLAMPPARTS (Continue@
93
,.
IS15500 (Part 8):2004
104.5 .+0.5
86.5 0 10334.2k .
II
I
— .—. —- —- —-— -—-—-
V
Surface Hardened to 30-50 HRC
8.2.7C Axle Pin
8.2.7D Split Pin
+0.0252 Holes 014 0
A I
8.2.7E Link Plate
All dimensionsin millimetres.
FIG. 8.2.7 SELF-LOCKINGCLAMPPARTS (Confinueo
,..
IS 15500 (Part 8) :2004
t-=--i
8.2.7F Spring
40 NB PIPE (MEDIUM)IS 1239 (PART 1) 1990INNER FACE MACHINED.
mo
I ‘--.LM+-LI029.5*0.2
56&.2
110Y
8.2.7G Lifter Block
8.2.7H Spring Retainer
FIG. 8.2.7
R6060
I 1F“ m
I
8.2.7 I Cover
All dimensions in miliimetres.
SELF-LOCKINGCLAMPPARTS(Continued)
95
/
--
IS 15500 (Part 8) :2004
P 5
1,I c’ I 1
I II
II
1 1A
I I .t
P Ill \ Ill +--- I---L\ t,l &
,I
Q1
l+-+. .
P I II
3
— - 4
d :1
_~:Oi*
1,1I
4
d ,+
+
-- --l-—-1
I!
II
—6 1 Pipe Lifier Holder5 2 Guide Pillar4 2 Supporting Pillar3 2 Supporting Pillar with Stopper2 1 Handle1 1 Base Plate
Part No. DescriptionNo. off
FIG. 8.2.7
/
$+-+I t
i I
11-—-—-——I
q
I
I II I
P2
P
6
Fig. 8.2.8F I Mild Steel I Grade A of IS 2062Fig. 8.2.8EFig. 8.2.8DFig. 8.2.8CFig. 8.2.8BFig. 8.2.8A
Referencem
Material
8.2.7J Base Assembly
All dimensions in millimetres.
SELF-LOCKINGCLAMPPARTS(Concluded
96
IS 15500 (Part 8): 2004
-: ,
A
115 I 115I
A-A
.+. .20+,02#-t
.- —-— -—-—
4 HOLES 014
F
—.- —
/
&+,---------./’ \
—-.
I
—-—
60. ●
“\I
+-.___—-. —I/’
—-
+-
f
8.2.8B Handle
All dimensions in millimetres.
FIG. 8.2.8 BASEASSEMBLYPARTS(Continuec.$
—
ah
TA
97
IS15500 (Part 8):2004
-----
--—
.----
.-l16
0.
—
I
@Y”I
-- -1--
J I
Sq 6
M15
II
II
II
25 25m ●
8.2.8C Supporting Pillar with Stopper
1
.----
—-
-----
0
t
1.
alb--b--l8.2.8D Supporting Pillar
All dimensions inmillimetres.
1bittm
+0.05020-0.02
8.2.8E Guide Pillar
8.2.8F Pipe-Lifter Holder
FIG. 8.2.8 BASEASSEMBLYPARTS(Concluded)
98
IS 15500 (Part 8) :2004
1-075i0.5
-1
11- Rp 2 (IS 554)i
IIA
I
II f
w--dI tw
1
/
t
II
To be made out of roddor seamless pipe
\ 016.5 Through Hole
2 1 F3pe,50 NB Mld Steel 1S 1239 (Part 1) — Medium1 1 Pipe Coupler M:ld Steel Grade A of IS 2062
I Part No. I No. Off\ Description I Material I1 1 I I [
All dimensions in millimetres.
8.3.1A
FIG. 8.3.1
Water Tank Lifter — VLOM-50
WATERTANKLIFTER(Confjnued)
99
,.-
IS15500 (Part 8):2004
088k0.5
Rp 2; (IS 554)9
I,
1
I
I
/
I
II
A!!R 2; (iS 554)
To be made out of rwt Jor seamless pipe
\ 016.5 Through Hola
Ipe, tee~ 2 1 P 65 NB 1S 1 9 (Part 1) — Medium1 1 Pipe Coupler M;ld Steel Grade A of IS 2062
Part No. No. Off Description Material
All dimensions in millimetres.
8.3.1 B
FIG. 8.3.1
Water Tank Lifter — VLOM-65
WATERTANKLIFTER(Concluded)
100
..__..
IS15500 (Part 8):2004
25 NB PIPE (HEAVY)
------- ----r -------.-----
/ ‘7
-------------- 1-—- :—-— -—- — —-— -—
------- ---------- ---------- -------------- :
5
m
--------------- -- --------------+--J - }—-—-—q--— -4--------------
1>/“
L
I 65670*3
-
Q2
45 14 13 12 11 1
Part No. No. OffzEnd Plug Mild SteelPipe,25NB Mild SteelSplit Rod Mild SteelHook Plate Mild Steel‘U’ Plate Mild Steel
Description
12.5 /
[p+--
025.5—
-— —- —
70*1
1- 135*1
Grade A of IS 20621S 1239 (Part 1) — HeavyGrade A of IS 2062Grade A of IS 2062Grade A of IS 2062
Material1
All dimensions in millimetres.
8.3.2A Pipe Lifting Spanner — VLOM-50
FIG. 8.3.2 PIPELIFTINGSPANNER(Corrfirruec7)
101
IS15500 (Part 8):2004
25 NB PIPE(HEAVY)
-------- ---- -----------.-
/ ‘7
-------------- 1-t-~— -—-—
-------L ------------------- -— -—-i--------------
5
WELDEDAND
—-— - — - —-— -
tI / I
-+ ~ ‘ i “ -12 206*1
Q2
30
E
.g
24
K5141312111
Part No.No. off
End PlugPipe, 25 NBSplitRodHook Plate‘U’ Plate
Description
135*1-1
Mild Steel I Grade Aof IS2062
Material
o3
Mild Steel IS 1239 (Part 1)— HeavyMild Steel GradeAofIS2062Mild Steel GradeAofIS 2062Mild Steel GradeAofIS2062
All dimensions in millimetres
8.3.2B Pipe Lifting Spanner — VLOM-65
FIG. 8.3.2 PIPELIFTINGSPANNER(COnChJded)
102
IS15500 (Part 8):2004
\
II.—
II -k #, -II It
,
7 1 Hex. Bolt M8 x 30 Std 07 Steel IS 1363 (Part 1)6 2 Hexagon Socket Head Std 08 Steel IS 2269
Cap Screw M1O x 255 1 Clamp Base Assembly Fig. 8.3.4E Mild Steel Grade A of IS 20624 1 Fixed Jaw Fig. 8.3.4D Mild Steel GrtuJe A of IS 20623 1 Handle Fig. 8.3.4C Mild Steel Grade A of IS 20622 1 Threaded Shaft Fig. 8,3.4B Mild Steel Grade A of IS 20621 1 Movable Jaw Fig. 8.3.4A Mild Steel Grade A of IS 2062
Part No. Description Reference MaterialNo. off
NOTE — This clamp is suited up to 45 m depth application, Alternative pipe clamp arrangements maybe used for application beyond 45 m.
All dimensions in millimetres.
8.3.3A Heavy Duty Clamp — VLOM-50
FIG. 8.3.3 HEAVYDUTYCLAMP(Continue@
103
IS 15500 (Part 8): 2004
7It
.—
II i .@II II
1 A, ,Ill
I I
+//
A
/
- +-+
v I_——.
/
-+)
[
:
1
t
-:
r1,
T
1
P2
7 1 Hex. Bolt MS x 30 Std 07 Steel IS 1363 (Part 1)6 2 Hexagon Socket Head Std 08 steel 1S2269
Cap Screw M1O x 255 1 Clamp Base Assembly Fig. 8.3.4E Mild Steel Grade A of IS 20624 1 Fixed Jaw Fig. 8.3.4D Mild Steel Grade A of IS 20623 1 Handle Fig. 8.3.4C Mild Steel Grade A of IS 20622 1 Threaded Shaft Fig. 8.3.4B Mild Steel Grade A of IS 20621 1 Movable Jaw Fig. 8.3.4A Mild Steel Grade A of IS 2062
Part No. Description Reference MaterialNo. off
NOTE — Thisclamp is suited up to 30 m depth application. Alternative pipe clamp arrangements maybe used for application beyond 30 m.
All dimensions in millimetres.
8.3.3B Heavy Duty Clamp — VLOM-65
FIG. 8.3.3 HEAVYDUTYCLAMP(Conchirfed)
104
IS15500 (Part 8):2004
b 94 I
— I In-+-o II-+*II I It I II , II11 II
I
II 11II II II
11 II II 11II I1,-- -- .11 IIII, J4 , hII I,\! /!
-i ‘+ -“+
1, /’!; l,! ,1.— -—-
:/ ,11 II, IIt
~$- :? a+-. $4&#
,.It
23k0.3 M8 x 30 deep
I
+’NN
1--- ---- J
i-l02273 4
; ‘ : 1 ~ ‘ 1
mIn
i616
-l-Q-l- 25” -@-l-
L SURFACE PUNCHED
CARBURISED AND HARDENED TO 4045 HRC
8.3.4A Movable Jaw
%
+
I
It
II
,$:’ ;‘:t------------;?~~ -——-1------------- m
1- 035J
8.3.4B Threaded Shaft
HEXNUTM16X2
TOBEPUNCHED LOCKEDHEXNUTM16X2 AFTERASSEMBLY INTHE
TOBESEALWELD CIAMP
. —.—- —-—- — --—-— -
1
300*3 --l
8.3.4C Handle
All dimensions in millimetres.
FIG. 8.3.4 HEAVYDUTYCLAMPpARTS(COntin~e@
105
IS15500 (Part 8):2004
[
coN
—.
I
30*0.11- 4
I
—
-3
—
30*0.1M1O X 1.5
-i
--l12 t I / w12
47*0.25 47*0.25
*
LSURFACEPUNCHED
Carburised and hardened to 40-45 HRC
8.3.4D Fixed Jaw — VLOM-65
All dimensions in millimetres.
FIG. 8.3.4 HEAVYDUTYCLAMPPARm”(Continued)’
IS15500 (Part 8):2004
i L
F .= ..=.=
--}--.- -—-
.-; -----
.= === .=
b I A , I A
I /“ ‘\,1; \ :I;A t , I
m PP (34
r.-—.-
/// // /
w/
-—- —- _-i_— — --—- * - -—
/
/ //
/ // // 37
,- -— 1,--
54321
PartNo.
11111
%off
CarryingHandleGuide PlateSupporting BlockSide PlateBase Plate
Fig. 8.2.5EFig. 8.2.5DFig. 8.2.5CFig. 8.2.5BFig. 8.2.5A
Mild Steel ] Grade A of IS 2062mMaterial
8.3.4E Clamp Base Assembly
All dimensions in millimetres.
FIG. 8.3.4 HEAVYDUTYCLAMPPARTS(Concluded)
107
. .
IS 15500 (Part 8) :2004
—-
Y— ---------~
/“ I -..
,/’,/
\/’ \
1’t’
1’I—. —___\\\\\\\
‘R6\
—-
k
32 180\
,i
—i—— -—-— -—
—- $-—\R12il
4s\
16
t—l—R12
-+
I
-r
+
4
------------------------1
5s!!d 1- 95 1. 95
cu
--------- ---------------
8.3.5B Side Plate
All dimensions in millimetres.
FIG.8.3.5 CLAMPBASEASSEMBLYPARTS(Continued)
108
IS15500 (Part 8):2004
115 115
18x45* 1-0
18X45”—I I P-
-id10
26 u40
230*2
ml r I
$ ! I 1
I 1
N .-3 I1F==== ===I
r-” “-l I- -l— —
J*4- -
:: ‘- a
UJ
dL - -1 II ~.=.. = .=. =1I !
—6
[ L!
I 248.3.5C Supporting Block
012
r
152t2
I
8.3.5D Guide Plate 8.3.5E Carrying Handle
All dimensions in millimetres.
FIG. 8.3.5 CLAMPBASEASSEMBLYPARTS(Concluded)
109
IS 15500 (Part 8): 2004
I
--%
/ 4
Ill
441322111
Part No.No. Off
Threaded Shaft Fig. 8.3.7DHandle Fig. 8.3.7CThreaded Bush Fig. 8.3.7BPIain Bush Fig. 8.3.7A
?
2
?
3
\\\\\\\\
.—-— - -—-— -
\\\\\\\\\
IF1
IEEEzrMild Steel IS 1239 (Part I)--Medium
Description I Reference ] Material
NOTES1 Items 1 and 4 to be carburized and hardened to 40-45 HRC.2 All parts to be electrogalvrmized to Service Grade No. 3 of IS 1573 and passivated.
FIG. 8.3.6 CHECKVALVEPULLER
110
IS 15500 (Part 8) :2004
040
I t-+% I
BO
8.3.7A Plain Bush
040
w tSq.Thread 018x 4
BOTH SIDES
8.3.7B Threaded Bush
120
------------- ----- -----------------
-—- —-— - —-— -—-
IS 1239 (Past 1)
8.3.7C Handle
LI
-1-
1
~
t==--=?
I
8.3.7D Threaded Shaft
All dimensions in millimetres
FIG. 8.3.7 PARTSOFCHECKVALVEPULLER
111
,.,
-... .. ... . ..———
/
IS 15500 (Parts 1 to 8) :2004
ANNEX A
(Cknfse 2 of Part 1)
LIST OF REFERRED INDIAN STANDARDS
1S No.
210:1993318:1981
407:1981
513:1994
549:1974554:1999
808:1989
1161:1998
1239
(Part 1): 1990(Part 2): 1992
1363
(Part 1): 2002
(Part 3): 2002
1364(Part 1): 2002
1367
(Part 2): 2002
(Part 11) :2002
(Part 14/Sec 1):2002
(Part 14/Sec2) :
2000
1573:1986
Title
Grey iron castings (fiourth revision)Leaded tin bronze ingots andcastings (second revision)Brass tubes for general purposes(third revision)Cold rolled low carbon steel sheetsand strips ~ourth revision)Split pins (second revision)Pipe threads where pressure-tight
joints are made on the threads —Dimensions, tolerances and designa-
tion ~ourth revision)Dimensions for hot rolled steelbeam, column, channel and anglesections (third revision)Steel tubes for structural purposes~ourth revision)Mild steel tub~s, tubular and otherwrought steel fittings:Mild steel tubes (fifth revision)Mild steel tubular and other wroughtsteel pipe fittings ~ourth revision)Hexagon head bolts, screws and nutsof product Grade C:Hexagon head bolts (size range M5to M64) (fiowth revision)Hexagon nuts (size range M5 toM64) ~ourth revision)Hexagon head bolts, screws andnuts of product Grades A & B: Part 1Hexagon head bolts (size rangeM 1.6 to M64) ~ourth revision)Technical supply conditions forthreaded steel fasteners:Tolerances for fasteners bolts,screws, studs and nuts—ProductGrades A, B and C (third revision)Electroplated coatings (thirdrevision)Mechanical properties of corrosionresistance stainless steel fasteners,Section 1 Bolts, screws and studs(third revision)Mechanical properties of corrosionresistance stainless steel filsteners,Section 2 Nuts (third revision)Electroplated coatings of zinc oniron and steel (second revision)
IS No.
2030:19892062:1999
2074:1992
2102(Part 1): 1993
2269:1995
2403:1991
2500(Part 1): 2000
2629:
2643:
985
999
2811:1987
2932:1993
3400
(Part 1): 1987
(Part2) :1995(Part 6): 1983(Part 10): 1977
(Part 22): 19843428:1981
4454(Part 1): 2001
Title
Box spanners (second revision)
Steel for general structural purposes— Specification (fifth revision)Ready mixed paints, air drying, redoxide zinc chrome, priming (secondrevision)
Generaltolerances: Part 1Tolerancesfor linear and angular dimensionswithout individual toleranceindications (third revision)
Fasteners — Hexagon socket headcap screws (third revision)
Short pitch transmission precisionsteel roller chains and chain wheels(second revision)Sampling inspection procedures:Part 1 Attribute sampling plansindexed by acceptable quality level(AQL) for lot-by-lot inspection (third
revision)
Recommended practice for hot dipgalvanizing on iron and steel (fzrstrevision)Pipe threads where pressure-tightjoints are not made on threads —Dimensions, tolerances anddesignation (second revision)
Recommendations for manualtungs~en inert gas arc welding ofstainless steel (j?rst revision)
Enamel, synthetic,exterior (a) under-coating (b) finishing(secondrevision)
Methods of test for vulcanizedrubbers:Tensile stress-strain properties(second revision)
Hardness (second revision)
Resistance to liquids @rst revision)
Compression set at constant strain@st revision)
Chemical analysisDimensions for relief grooves (firstrevision)
Steel wires for mechanical springs:Patented and cold drawn steel wires,unalloyed (third revision)
112
IS 15500 (Parts 1 to 8): 2004
IS No.
4695(Part 1): 1!?88
(Part 2): 1988
4740:1979
4759:1996
5206:1983
5517:1993
6455:19726603:2001
Title
Knuckle screw threads:Thread profiles and nominaldimensions ~rst revision)Deviations and tolerances @rstrevision)Code of practice for packaging ofsteel tubes ~rst revision)Hot-dip zinc coatings on structuralsteel and other allied products (thirdrevision)Covered electrodes for manual arcwelding of stainless steel and othersimilarhigh alloy steels@st revision)Steels for hardening and tempering(second revision)Single row radial ball bearingsStainless steel bars and flats @rs/revision)
IS No.
6912:1985
7002:1991
9550:1980
9595:1996
9839:1981
14962(Part 3): 2001
Title
Copper and copper alloys forgingstock and forgings (jlrst revision)Prevailing torque type steel hexagonlocknut (with non-metallic insert)style 1 Property classes 5, 6 and 10— Specification @st revision)Bright barsMetal arc welding of carbon andcarbon manganese steels —Recommendations (first revision)Chromate conversion coating onelectroplated zinc and cadmiumcoatings1S0 general purpose metric screwthreads — Tolerances: Part 3Deviation for constructional screwthreads
113
f
IS 15500 (Parts 1 to 8): 2004
ANNEX B
(Clause 4.6 of Part 1)
STANDARD COMPONENTS
s] ID No. Part Description Ref to IS No.
No.Name Size
i) Std 01 Hexagonal nut (stainless steel) Mfjxl IS 1367 (Part 14/Sec 2)
ii) Std 02 Hexagonal lock nut MS x 1.25 IS 1363 (Part 3)
iii) Std 03 Prevailing torque type steel hexagonal nut M1O X 1.5 IS 7002
iv) Std 04 Hexagonal nut M12 x 1.75 IS 1363 (Part 3)
v) Std 05 Hexagonal bolt (stainless steel) Mfjxlxzs IS 1367 (Part 14/Sec 1)
vi) Std 06 Hexagonal bolt M8 X1.25X2(-J IS 1363 (Part 1)
vii) Std 07 Hexagonal bolt M8x1.’25x3O IS 1363 (Part 1)
viii) Std 08 Hexagonal socket head cap screw M10XI.5 X25 IS 2269
ix) Std 09 Hexagonal bolt M1OX1.5X4O IS 1364 (Part 1)(Property class 8.8)
x) Std 10 Hexagonal bolt M12 X 1.75 X20 IS 1363 (Part 1)
xi) Std 11 Hexagonal bolt M12 X 1.75 X30 IS 1364 (Part 1)(Property claw 10.9)
xii) Std 12 Hexagonal bolt M12 x 1.75 x 40 IS 1363 (Part 1)
xiii) Std 13 Hexagonal bolt M12 x 1.75 xL1) IS 1363 (Part 1)
xiv) Std 14 Split pin 06 X 45 IS 549
xv) Std 15 Ball bearing, single side shielded 20 BC 02 PP IS 6455
xvi) Std 16 Roller chain (1S0 16B) 25.4 mm pitch IS 2403
i,-
q.,
J)‘fhc length L of this bolt ~il[ d~Pcnd ~pon the number of counterweights used in the extra deepwell pump.
114
,..
I
IS 15500( Parts 1 to 8) :2004
ANNEX C
(Clause 12.1 of Part 1)
RECOMMENDED PACKAGING PROCEDURE
.
S1 Sub-assembly/Component Individual Packing Bulk PackingNo.
Identifi- Nomenclaturecation/Figure
No.
(1) (2) (3) (4) (5)
1. 3.1 Head Assembly —StandardHandle Assembly —
Covered with polyethylene bag,2. 3.2
Standardwrapped in straw rope with hessiancover
3. 3.3 Head Assembly — EDWP
4. 3.4Handle Assembly —EDWP
Cylinder Assembly —Cardboard box
5. 3.5Standard
Polyethylene bag (maximum threenumbers per box)
6. 3.6AUpper Valve Assembly —Standard Polyethylene bag, individually cardboard box
7. 3.6BLower Valve Assembly — packed in cardboard cartonStandard
Cylinder Assembly — Cardboard box8. 3.7
VLOM-65Polyethylene bag (maximum three
numbers per box)
9. 3.8AUpper Valve Assembly —VLOM-65 Polyethylene bag, individually cardboard box
lo. 3.8BLower Valve Assembly — packed in cardboard cartonVLOM-65
Cylinder Assembly — Cardboard box11. 3.9
VLOM-50Polyethylene bag (maximum three
numbers per box)
12. 3.IOAUpper Valve Assembly —VLOM-50 Polyethylene bag, individually cardboard box
13. 3.IOBLower Valve Assembly — packed in cardboard cartonVLOM-50
Cylinder Assembly — Cardboard box14. 3.11
EDWPPolyethylene bag (maximum three
numbers per box)
15. 3.12AUpper Valve Assembly —EDWP Polyethylene bag, individually Cwdboud box
16. 3.12BLower Valve Assembly — packed in cardboard cartonEDWP
17. 4.1 Head - Standard Covered with polyethylene bag,wrapped in straw rope with hessian
18. 4“2 Head — EDWP—
cover
Wooden crate19. 4.4 Cover Polyethylene bag (maximum 32
numbers per crate)
I
. .
i
115
..
IS 15500 (Parts 1 to 8) :2004
SI Sub-assembly/Component Individual Packing Bulk PackingNo.
Identifi- NomenclaturecatiotiFigure
No.
(1) (2) (3) (4) (5)
Hessian bag withstraw packing
20. 4.5 Third Plate Polyethylene bag (maximum weightnot to exceed 50 kgper pack)
21. 4.6 Handle — Standard Covered with polyethylene bag,
22. 4.7 Handle — EDWPwrapped in straw rope with hessian —
cover
23. 4.9 Chain with couplingPolyethylene bag(see also C-6.2)
Cardboard box
24. 4.10 T-bar — EDWP Hessian cover
Polyethylene bag(maximum weight
25. 4.11 Counter Weight — EDWP not to exceed 50 kgper pack)
26. 4.12 Stand — Standard . Covered with polyethylene bag,27. 4.13 Stand — EDWP wrapped in straw rope with hessian28. 4.15 Water Tank — 32 cover. M 12x40 bolt with two nuts —
29. 4.16 Water Tank — 50 to be provided in each hole of top
30. 4.17 Water Tank — 65 flange
31. 4.19 Cone Plate — VLOM-65 Hessian bag withstraw packing
32. 4.20 Cone Plate — VLOM-50Polyethylene bag (maximum weight
not to exceed 50 kgper pack)
Polyethylene (up to ten rods perHessian cover
33. 4.21 Connecting Rodbag) (see also A-11.3)
(maximum tennumbers per pack)
34. 4.22 Plunger Rod — Standard Polyethylene (up to ten rods perHessian cover
35. 4.23 Plunger Rod — Long bag) (see also A-1 1.3)(maximum twentynumbers per pack)
36. 4.24 Handle AxlePolyethylene sleeve with thread ~protector
Cardboard box
37. 4.25 Push RodPolyethylene bag (up to 50 Cardboard boxnumbers per pack)
38. 4.26 Bearing SpacerPolyethylene bag (up to 20
Cardboard boxnumbers per pack)
39. 4.27 WasherPolyethylene bag (up to 100
Cardboard boxnumbers per pack)
40. 4.28 Socket 32 NB, seamless
41. 4.29 Socket 50 NB, seamless Polyethylene cover Cardboard box
42. 4.30 Socket 65 NB, seamless
43.5.1 and Cylinder Body with Liner
6.1A — Standard Cardboard box
44.5.2 and Cylinder Body with Liner Polyethylene bag with thread (maximum weight
5.1 B — Long protector not to exceed 50 kg
5.3 and Cylinder Body with Liner45.
per pack)
6.lC — VLOM-50
116
IS 15500( Parts 1 to 8) :2004
S1 Sub-assembly/Component Individual Packing Bulk Packing
No.Identifi- NomenclaturecationlFigure
No.
(1) (2) (3) (4) (5)
46. 5.4 Reducer Cap
47.5.5AI Cylinder Caps — VLOM-5.5B 65 Polyethylene bag
Cardboard box
48.5.6AI Cylinder Caps — VLOM-5.6B 50
49. 6.2 Plunger Yoke BodyPolyethylene cover and cardboard
Cardboard boxcarton, individually
50. 6.3 Upper ValvePolyethylene cover and cardboard
Cardboard boxcarton, maximum five per pack
51. 6.4 Bucket Spacer — Standard Polyethylene cover and cardboard
52. 6.5 Bucket Spacer — LowerCardboard box
carton, maximum five per pack
53. 6.6 Follower — SDWP
54. 6.7 Follower — VLOM-65Polyethylene cover and cardboard Cardboard box
55. 6.8 Follower — EDWPcarton, individually
Polyethylene cover with thread56. 6.9 Check Valve — Standard protector, and cardboard carton Cardboard box
individually
57. 6.10 Check Valve — VLOM-65Polyethylene cover and cardboard
Cardboard boxcarton, maximum five per pack
58. 6.11 Rubber Seat RetainerPolyethylene cover and cardboard
Cardboard boxcarton, maximum ten per pack
59. 6.12Check Valve Seat — Polyethylene cover and cardboardStandard
Cardboard boxcarton, maximum five per pack
60. 6.13Check Valve Seat — Polyethylene cover and cardboardVLOM-65
Cardboard boxcarton, individually
61. 6.14 Cage — VLOM-65Polyethylene cover and cardboardcarton, individually
Cardboard box
62.Plunger Body — VLOM-
6.15 soPolyethylene cover and cardboard
Cardboard boxcarton, individually
63. 6.16Check Valve Body — Polyethylene cover and cardboardVLOM-50
Cardboard boxcarton, individually
64. 7.1 Pump Bucket — Standard Polyethylene cover and cardboardPump Bucket — VLOM-
65. 7,2 soplastic container, maximum ten per Cardboard boxpack
66. 7.3 Sealing Ring — Standard Polyethylene cover and cardboard /67. 7.4 Sealing Ring — VLOM-65 plastic container, maximum 50 Cardboard box
68. 7.5 Sealing Ring — VLOM-50 numbers per pack
69. 7.6 Upper Valve Seating
70. 7.7Lower Valve Seating — Polyethylene cover and cardboardStandard carton, maximum 100 numbers per Cardboard box
71. 7.8Lower Valve Seating — “ pack
VLOM-65
72. 7.9 BobbinPolyethylene cover and cardboard
Cardboard boxcarton
73. 7.10 O-Ring — VLOM-65 Polyethylene cover and cardboard74. 7.11 O-Ring — VLOM-50
Cardboard boxcarton
117
Q,. . . . .._. ——.————
- “.,.
!
IS 15500 (Parts 1 to 8) :2004
slNo.
Sub-assembly/Component
ldentifi- NomenclaturecationlFigure
No.
Individual Packing
I (1) I (2) I (3) I (4)
75. I 7.12 I Rubber Cone — VLOM-65 I Polyethylene cover and cardboard
76. 7.13 I Rubber Cone — VLOM-50 ] carton
77. 7.14Rubber Centralizer —VLOM-65 Polyethylene cover and cardboard
78. 7.15Rubber Centralizer — carton
VLOM-50
Bulk Packing
Cardboard box
Cardboard box
STANDARD COMPONENTS
SINo.
79.
80.
81.
82.
Identifi-cation/
Item No.in
Annex B
Std 01
Std 02
Std 03
Std 04
-rt-mR-
=t==
~
87. Std 09
88. Std 10
89. Std 11
90. Std 12
91. Std 13
92. Std 14
93. Std 15
Component I Individual Packing
Nomenclature
(5)
Hexagonal Nut (SS) M6 Polyethylene bag, maximum 100 No. per bag
Hexagonal Lock Nut M8 Polyethylene bag, maximum 100 No. per bagI
Nyloc Hexagonal Nut MIO IPolyethylene bag, maximum 100 No. per bagI
Hexagonal Nu~M12 ]Polyethylene bag, maximum 50 No. per bag1
Hexagonal Bolt (SS) M6 x 28 IPolyethylene bag, maximum 50 No. per bag1
Hexagonal Bolt M8 x 20 ]Polyethylene bag, maximum 50 No. per bag1
Hexagonal Bolt M8 x 30 IPolyethylene bag, maximum 50 No. per bag!
Hexagonal Socket Head ScrewM8 X 30 Polyethylenebag, maximum50 No. per bag
Hexagonal Bolt M1O x 40-8.8 IPolyethylene bag, maximum 50 No. per bag!
Hexagonal Bolt M12 x 20 IPolyethylene bag, maximum 50 No. per bagI
Hexagonal Bolt M12 x 30 IPolyethylene bag, maximum 50 No, per bag1
Hexagonal Bolt M12 x 40 IPolyethylene bag, maximum 25 No. per bag1
Hexagonal Bolt M12 x 100 IPolyethylene bag, maximum 10 No. per bagI
Split Pin ]Polyethylene bag, maximum 100 No: per bag
Ball BearingPolyethylene cover and cardboard carton,individually
TBulk Packing
:ardboard box
hrdboard box
hrdboard box
%dboard box
%rdboard box
%rdboard box
:ardboard box
:ardboard box
:ardboard box
hrdboard box
:ardboard box
:ardboard box
:ardboard box
%rdboard box
;ardboard box I
NOTE— The cardbowd box for bulk supply shall be of 7 ply corrugated tibre board (CFB)madeof 120GSMkraft paper withcIoth lining inside. The box shall be sufficientlystrappedwith 12mmpolypropylenestrap. The grossweightof the box with itscontentsshall not exceed25 kg.
118
IS 15500 (Parts 1 to 8) :2004
ANNEX D
(Clause 1.3 of Part 8)
LIST OF TOOLS IN A SET OF SPECIAL TOOLS FOR INSTALLATION AND/OR MAINTENANCE
D-1 SET OF TOOLS FOR INSTALLATION ANDMAINTENANCE OF STANDARD DEEPWELLAND EXTRA DEEPWELL HANDPUMPS
S1No. Description Qty Figure
i) Connecting rod vice 1 No. 8.1.1
ii) Axle punch 1 No. 8.1.4
iii) Chain coupler supporting tool 1 No. 8.1.5
iv) Crank spanner 2 No. 8.1.6
v) Connecting rod lifter 1 No. 8.1.7/8.1.8
vi) Bearing pressing tool 1 No. 8.1.9
vii) Rod coupler spanner 2N0. 8.1.10
viii) Water tank lifter 1 No. 8.2.1ix) Pipe lifting spanner 3 No. 8.2.2
x) Heavy duty clamp, or 1 No. 8.2.3
self-locking clamp 1 No. 8.2.6
xi) Tool box 1 No. —
D-2 SET OF TOOLS FOR INSTALLATION AND/OR MAJOR REPAIR OF VLOM HANDPUMPS
D-2.1 For VLOM-65 Handpumps
S1No. Description QtYi) Connecting rod vice 1 No.
i] Axle punch 1 No.iii) Chain coupler supporting tool 1 No.iv) Crank spanner 2 No.
v) Connecting rod lifter 1 No.
vi) Bearing pressing tool 1 No.vii) Rod coupler spanner 2 No.
viii) Water tank lifter 1 No.
ix) Pipe lifting spanner 3 No.
Figure
8.1.1
8.1.4
8.1.5
8.1.6
8.1.7/8.1.8
8.1.9
8.1.10
8.3.1
8.3.2
SINO. Description Qty Figure
x) Heavy duty clamp 1 No. 8.3.3
xi) Check valve puller 1 No. 8.3.6
xii) Tool box 1 No. —
D-2.2 For VLOM-50 Handpumps
S1No. Description Qty Figure
i) Connecting rod vice INo. 8.1.1
ii) Axle punch 1 No. 8.1.4
iii) Chain coupler supporting tool 1 No. 8.1.5iv) Crank spanner 2 No. 8.1.6
v) Connecting rod lifter 1 No. 8.1.7/8.1.8
vi) Bearing pressing tool 1 No. 8.1.9vii) Rod coupler spanner 2N0. 8.1.10
viii) Water tank lifier 1 No. 8.3.1 A
ix) Pipe lifting spanner 3 No. 8.3.2Ax) Heavy duty clamp 1 No. 8.3.3 A
xi) Check valve puller 1 No. 8.3.6xii) Tool box 1 No. —
D-3 SET OF SPECIAL TOOLS FORMAINTENANCE OF VLOM HANDPUMPS(BOTH VLOM-65 AND VLOM-50)
S1No. Description Qty Figure
i) Connecting rod vice lNo. 8.1.1ii) Chain coupler supporting tool 1 No. 8.1.5
iii) Crank spanner 2 No. 8.1.6
iv) Connecting rod lifter 1 No. 8.1.7/8.1.8v) Rod coupler spanner 2N0. 8.1.10
vi) Check valve puller 1 No. 8.3.6
vii) Tool box 1 No. —
119
,7J-i , .
},
i;
Bureau of Indian Standards
BIS is a statutory institution established under the Bureau of Indian Standards Act, 1986 to promoteharmonious development of the activities of standardization, marking and quality certification of goodsand attending to connected matters in the country.
Copyright
BIS has the copyright of all its publications. No part of these publications may be reproduced in any formwithout the prior permission in writing of BIS. This does not preclude the free use, in the course ofimplementing the standard, of necessary details, such as symbols and sizes, type or grade designations.Enquiries relating to copyright be addressed to the Director (Publications), BIS.
Review of Indian Standards
Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewedperiodically; a standard along with amendments is reaft%med when such review indicates that no changes areneeded; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standardsshould ascertain that they are in possession of the latest amendments or edition by referring to the latest issue of‘BIS Catalogue’ and ‘Standards : Monthly Additions’.
This Indian Standard has been developed from Doc : No. ME 27 (0487).
Amendments Issued Since Publication
Amend No. Date of Issue Text Affected
BUREAU OF INDIAN STANDARDS
Headquarters :
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002Telephones :23230131,23233375,2323 9402
Regional Offices :
Central : Manak Bhavan, 9 Bahadur Shah Zafar MargNEW DELHI 110002
Eastern : 1114C.I.T. Scheme VII M, V. I. P. Road, Kankurgachi
Northern
Southern
Western
Branches :
KOLKATA 700054
: SCO 335-336, Sector 34-A, CHANDIGARH 160022
: C.I.T. Campus, IV Cross Road, CHENNAI 600113
: Manakalaya, E9 MIDC, Marol, Andheri (East)MUMBAI 400093
Telegrams : Manaksanstha(Common to all offices)
Telephone
{
2323761723233841
{
23378499,2337856123378626,23379120
{
26038432609285
{
22541216,2254144222542519,22542315
{
28329295,2832785828327891,28327892
AHMEDABAD. BANGALORE. BHOPAL. BHUBANESHWAR. COIMBATORE. FARIDABAD.GHAZIABAD. GUWAHATI. HYDERABAD. JAIPUR. KANPUR. LUCKNOW. NAGPUR.NALAGARH. PATNA. PUNE. RAJKOT. THIRUVANANTHAPURAM. VISAKHAPATNAM.
Pmted at Rabhat Offset Press, New Delhi-2
,.