Precise dose calculations within seconds for SBRT Unmatched speed and intuitive user interface enable broader treatment spectrum and use with every patient brainlab.com iPLAN ® MONTE CARLO DOSE CALCULATION iPlan ® Monte Carlo dose calculation offers fast, accurate dose calculations for more precise treatment of extracranial indications—expanding SBRT treatment possibilities. iPlan Monte Carlo performs dose calculations within seconds for conformal beam and dynamic arc treatments and within minutes for complex IMRT cases. Seamless integration allows for use with all major linear accelerators and multi-leaf collimator (MLC) types. This advanced calculation method eliminates treatment area restrictions of conventional dose calculation algorithms 1 for highly precise treatment delivery to inhomogeneous regions including lung and head & neck indications. Customizable solution adapts to specific Linac and MLC configurations Integrates with iPlan RT Image and Automatic contouring tools to further enhance treatment planning efficiency, consistency and accuracy Enables photon based MLC treatments including conformal beam, dynamic arc, IMRT and composite planning for combined treatment modalities iPlan Monte Carlo IMRT dose display for head & neck indications

Transcript of iPlan Monte Carlo Dose Calculation Flyer

Page 1: iPlan Monte Carlo Dose Calculation Flyer

Precise dose calculations within seconds for SBRT

Unmatched speed and intuitive user interface enable broader treatment spectrum and use with every patient

brainlab.com

iPLAN® MONTE CARLO DOSE CALCULATION

iPlan® Monte Carlo dose calculation offers fast, accurate dose calculations for more precise treatment of extracranial indications—expanding SBRT treatment possibilities. iPlan Monte Carlo performs dose calculations within seconds for conformal beam and dynamic arc treatments and within minutes for complex IMRT cases. Seamless integration allows for use with all major linear accelerators and multi-leaf collimator (MLC) types. This advanced calculation method eliminates treatment area restrictions of conventional dose calculation algorithms1 for highly precise treatment delivery to inhomogeneous regions including lung and head & neck indications.

Customizable solution adapts to specific Linac and MLC configurations

Integrates with iPlan RT Image and Automatic contouring tools to further enhance treatment planning efficiency, consistency and accuracy

Enables photon based MLC treatments including conformal beam, dynamic arc, IMRT and composite planningfor combined treatment modalities

iPlan Monte Carlo IMRT dose display for head & neck indications

Page 2: iPlan Monte Carlo Dose Calculation Flyer

1Dobler B, et. al. Optimization of extracranial stereotactic radiation therapy of small lung lesions using accurate dose calculation algorithms, Radiation Oncology 1 (2006) 45.2Fippel M: Efficient particle transport simulation through beam modulating devices for Monte Carlo treatment planning, Medical Physics 31 (2004) 1235-1242.©2008 BrainLAB AG. Printed in USA. RT-FL-E-iPlanMonteCarlo 0908 Q:4000 ®registered trademark of BrainLAB AG in Germany and/or the US.

brainlab.com

iPlan® Monte Carlo is a high performance Monte Carlo algorithm for therapeutic photon beam radiation delivery. Based on the XVMC (X-Ray Voxel Monte Carlo) algorithm, iPlan Monte Carlo was developed to provide high-precision treatment in everyday clinical practice and has been verified using the widely respected EGSnrc and BEAMnrc algorithms.

iPlan Monte Carlo is an integral part of iPlan RT Dose, offering advanced technology for multiple treatment approaches. iPlan Monte Carlo considers Linac head geometry, secondary electron dose effects and tissue inhomogeneities2, providing clinicians with faster and more accurate dose calculation for SBRT.

“The new iPlan Monte Carlo algorithm integrates some of the most advanced tools available in the clinical environment, including image registration and segmentation tools, providing a powerful instrument to tackle the most challenging radiosurgery cases in lung and head & neck sites.”

Kamil Yenice, Ph.D., Chief of Clinical Physics, University of Chicago, Department of Radiation and Cellular Oncology, USA

MORE PRECISE TREATMENT DELIVERY

“The iPlan Monte Carlo algorithm improves dose plan accuracy for radiotherapy and radiosurgery especially for extracranial indications. Specifically for tumors in the lung and head & neck regions, we are now able to more precisely define the borders between tissue of different consistency. That allows us to reach an improved starting point in order to optimize the planned dosage in the affected regions.”

Tilo Wiezorek, Ph.D., University Clinic Jena, Clinic for Radiation Therapy and Radiation Oncology, Germany

Comparison of iPlan Monte Carlo (inner plan) and Pencil Beam (outer plan) for dose correction in small lung tumor

iPlan Monte Carlo IMRT dose display for head & neck indications