Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection...

44
State of the Art Cathodic Protection Practices and Equipment

Transcript of Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection...

Page 1: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

State of the Art Cathodic Protection Practices and 

Equipment 

Page 2: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

State of the Art

Definition:

The level of development (as of a device, procedure, process, technique, or science) reached at any particular time usually as a result of modern methods

Page 3: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Cathodic Protection 

Type

Materials

Installation

Monitor / Survey Techniques

Page 4: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Types of Cathodic Protection

Sacrificial Anode

Small Current Requirement• Well Coated Structures

• Isolated Structures

Low to Medium Soil Resistivity

Page 5: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Types of Cathodic Protection

Impressed Current

Large Current Requirement• Poorly Coated Structures

• Shorted Structures

High Soil Resistivity

Page 6: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Sacrificial AnodesMagnesium & Zinc Typical

Page 7: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Sacrificial AnodeZinc Ribbon

Page 8: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

GRADE

SINGLE ANODE

PIPE

AN

OD

E

AT PIPE DEPTHTO 5' TYPICAL

5' MIN

GRADE

MULTIPLE ANODE

PIPE

AN

OD

E

AN

OD

E

AN

OD

E

AN

OD

E

5' TO 15'TYPICAL

10'-15' MINFOR MAGNESIUM5' MIN FOR ZINC

TYPICAL SACRIFICIAL ANODE INSTALLATION

Page 9: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Typical Sacrificial Anode Installation

Page 10: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Typical Sacrificial Anode Installation

Page 11: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Typical Sacrificial Anode InstallationRibbon Anode

Page 12: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Impressed Current Rectifier

Constant Voltage

Constant Current

Auto Potential

Pulse

Alternative PowerSolar

Thermo Electric

Wind

Hydro

Page 13: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Impressed Current AnodeGraphite

Page 14: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Impressed Current AnodeHigh Silicon Cast Iron

Page 15: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Impressed Current AnodeMixed Metal Oxide

Page 16: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

- +

RECTIFIER

PIPE

PIPE

AN

OD

E

AN

OD

E

AN

OD

E

AN

OD

E

AN

OD

E

AN

OD

E

TYPICAL IMPRESSED CURRENT ANODE INSTALLATIONDISTRUBUTED

Page 17: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

200' TO 500' TYPICAL

- +

RECTIFIER

TYPICAL IMPRESSED CURRENT ANODE INSTALLATIONREMOTE

PIP

E

ANODES

Page 18: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

PIPE

- +

50' T

O 4

00'

TYP

ICA

L

ANODE WITHIN SLURRIED BACKFILL

TYPICAL IMPRESSED CURRENT ANODE INSTALLATIONDEEP

Page 19: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

GRADE

TO ANODE JUNCTION BOXMINIMUM 2'-0" BURIAL

SURFACE CASING TO 40 FT

VENT PIPE

SAND / BENTONITE MIXTURE

ANODE LEAD WIRES / HALAR

ANODES 10 EACH ON 10 FT CENTERS

LOW RESISTANCE BACK-FILL BOTTOM FILLED SLURRIED

GRADE

10"

125'

75'

200'

Page 20: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Impressed Current Anode InstallationDistributed or Remote

Page 21: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Impressed Current Anode InstallationDeep

Page 22: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Storage Tank Bottom CPNew                           Existing

Page 23: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Vacuum Excavation

• Utility Locating• Anode Installation• Reference Cell Installation

• Test Station Installation• Depth of Cover Survey• Expose Pipeline for Coating Inspection

• Subsurface Utility Engineering

Page 24: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Vacuum ExcavationUtility Locate

Page 25: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Vacuum ExcavationAnode / Test Station Installation

Page 26: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Cathodic Protection Testing

Equipment

Tools

Materials

Survey Methods

Page 27: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

+

0.000

CLEAN WATER

HIGH INPUT IMPEDANCE DIGITAL VOLT METER10 M OR GREATER

COPPER/COPPER SULFATE REFERENCE CELLCLEAN, FULLY CHARGED & CALIBRATED

TEST WIRES WITH ALLIGATOR CLIPSSELECTION OF SHORT & LONG WITH NO SPLICES

CLEAN WATERTO SATURATE THE TEST LOCATION

MISC. HAND TOOLSTO MAKE MINOR REPAIRS ON-SITE

C.P. TEST EQUIPMENT

Page 28: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Data CollectionRead Only                 Self Storage

Page 29: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Reference Cell / Electrode

SATURATED COPPER SULFATE SOLUTION

PURE COPPER ROD

COPPER SULFATE CRYSTALS

POROUS PLUG

O-RING SEAL

ELECTRODE BODY

O-RING SEAL

• Contaminated every time it gets used

Clean Regularly

Check Regularly

• The “Weakest Link” in Cathodic Protection Testing

Page 30: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Cathodic Protection CriteriaNACE SP0169

1. ‐850 mV with IR Drop Considered

2. ‐850 mV Polarized

3. 100 mV Polarization

Page 31: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

CP Test Location / Test Station

Page 32: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

+

- 0.850 V

PIPE

STRUCTURE TERMINAL

VOLT METERREFERENCECELL TERMINAL

PERMANENT REFERENCE CELL

1. CONNECT (+) LEAD OF VOLT METER TO STRUCTURE TERMINAL 2. CONNECT (-) LEAD OF VOLT METER TO REFERENCE CELL TERMINAL 3. READ & RECORD MEASURED POTENTIAL

C.P TESTING - PERMANENT REFERENCE CELL

Page 33: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Permanent Reference Electrode

Page 34: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

+

- 0.850 V

PIPE

+

- 0.850 V

PIPE

C.P TESTING - PORTABLE REFERENCE CELL

1. CONNECT (+) LEAD OF VOLT METER TO STRUCTURE TERMINAL 2. CONNECT (-) LEAD OF VOLT METER TO REFERENCE CELL TERMINAL 3. PLACE REFERENCE CELL DIRECTLY OVER OR ADJACENT TO PIPE 4. READ & RECORD MEASURED POTENTIAL

VOLT METER

REFERENCE CELL

C.P. TEST STATION

STRUCTURE TERMINAL

STRUCTURE TESTWIRE

VOLT METER

Page 35: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

PROPER REFERENCE CELL PLACEMENT

PIPE

GRADE

AN

OD

E.850V

AN

OD

E

100' (TYPICAL)

Page 36: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Coupon Test Station

• IR Free Potential Reads

• No Need to Interrupt:Rectifiers

Sacrificial Anodes

Foreign Bonds

• Calculate Metal Loss

Page 37: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Remote Monitoring

• GPS Controlled• Automatic Pipe‐to‐Soil Potential Reads

• Automatic Rectifier Voltage & Amperage Reads

• Alarm Notification• Interruption Capabilities• Cellular, Satellite & Radio Communication

Page 38: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Circuit Interruption

• Rectifiers & Foreign Bonds

• Sacrificial Anodes

• GPS Controlled

• Programmable Schedule

Page 39: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Fault Protection & Grounding

• Solid State

• Induced AC Voltage Mitigation

• Stray DC Voltage Blocking

• Insulated Joint Protection

Page 40: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Ultrasonic Thickness (UT) Gauges

Page 41: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Thermite Welding

Page 42: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Over‐the‐LineSurvey Techniques

Page 43: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures

Over‐the‐LineSurvey Techniques

Close Interval Survey (CIS)• Cathodic Protection Potential Profile

Pipeline Current Mapping (PCM)• Maps Cathodic Protection Current Loss due to Coating Failure or Shorted conditions

Direct Current Voltage Gradient (DCVG)Alternating Current Voltage Gradient (ACVG)• Pinpoints Coating Defects

Page 44: Iozzo - State of the Art Cathodic Protection · PDF fileTypes of Cathodic Protection Sacrificial Anode ¾Small Current Requirement • Well Coated Structures • Isolated Structures