IO-Link Technology Enables Industry 4.0 and IIoT …...OPC-UA upstream to IIoT/Industrie 4.0 Cloud...

4
IO-Link Technology Enables Industry 4.0 and IIoT Solutions IIoT benefts with direct sensor connection through OPC UA.

Transcript of IO-Link Technology Enables Industry 4.0 and IIoT …...OPC-UA upstream to IIoT/Industrie 4.0 Cloud...

Page 1: IO-Link Technology Enables Industry 4.0 and IIoT …...OPC-UA upstream to IIoT/Industrie 4.0 Cloud solutions or SCADA systems. BENEFITS OF OPC UA • No PLC required • The IO-Link

IO-Link Technology Enables

Industry 4.0 and IIoT SolutionsIIoT benefits with direct sensor connection through OPC UA.

Page 2: IO-Link Technology Enables Industry 4.0 and IIoT …...OPC-UA upstream to IIoT/Industrie 4.0 Cloud solutions or SCADA systems. BENEFITS OF OPC UA • No PLC required • The IO-Link

Comtrol’s IO-Link Masters to simultaneously provide a sensors Process data to PLC platforms, while also sending the sensors ISDU Service and Process data via Modbus TCP or OPC-UA upstream to IIoT/Industrie 4.0 Cloud solutions or SCADA systems.

BENEFITS OF OPC UA

• No PLC required • The IO-Link Master OPC UA series combines the benefits of the IO-Link standard, OPC UA and

additional use of EtherNet/IP™, Modbus TCP and PROFINET IO protocols simultaneously.• Comtrol’s IO-Link Master allows you to solely use OPC-UA, without a PLC involved, which

saves on hardware and software costs.• Send IO-Link or Digital device information directly up to software systems such as Ignition,

Xetics, GE Proficy, Wonderware, Iconics, or any other client software supporting OPC UA.• Open architecture • IIoT and Industry 4.0 enabled • Simultaneous connection using

• EtherNet/IP, OPC UA and Modbus TCP • Profinet, OPC UA and Modbus TCP

• Provide sensor data to monitor machine efficiency• Countless application possibilities

ENABLING INDUSTRY 4.0 WITH OPC UA

Page 3: IO-Link Technology Enables Industry 4.0 and IIoT …...OPC-UA upstream to IIoT/Industrie 4.0 Cloud solutions or SCADA systems. BENEFITS OF OPC UA • No PLC required • The IO-Link

OPC UA PROVIDES SENSOR DATA ANALYTICS

Page 4: IO-Link Technology Enables Industry 4.0 and IIoT …...OPC-UA upstream to IIoT/Industrie 4.0 Cloud solutions or SCADA systems. BENEFITS OF OPC UA • No PLC required • The IO-Link

COMTROL’S IO-LINK GATEWAY USER BENEFITS

Comtrol, a company with a long history of industrial data communication solutions, is pleased to introduce the industry’s highest density IO-Link Master gateway. Easily integrate the IO-Link Master into a system network with existing and new industrial Ethernet installations.

• Increase sensor data availability to multiple software hosts

• Reduce maintenance and cabling costs

• Reduce PLC programming times

• System integration and interoperability for SCADA; process controllers

• Complete set of network management tools

Comtrol’s IO-Link gateways support both Class 1 and Class 3 EtherNet/IP™ as well as Modbus TCP and PROFINET IO. The gateways are compatible with a vast array of PLCs, both new and old.

PLC Controller Supported:• Siemens• Rockwell Automation• Omron• GE• Schneider Electric• ABB• Codesys

• Any Modbus enabled PLC, HMI, SCADA that can run as a Modbus TCP Master (Client)

• Any Modbus TCP Client (including apps on phones/tablets)

COMTROL’S IO-LINK MASTER GATEWAY FEATURES

• MultiLink™ – Simultaneously provides IO-Link device access to multiple controllers• Supports EtherNet/IP™, Modbus TCP and PROFINET IO• Powerful IO-Link Master web interface unlike any other in the industrial marketplace:

• Mobile Application – Configuration and Diagnostics• PROFINET GDSML file integration for TIA portal • ISDU (Indexed Service Data Unit) Handling• RSLogix Integration – PLC Interface configured through AOI file• Ability to save and load IO-Link Master configuration files• Network Management Tools• Clone Config to program 2-50 Master’s configuration settings

• Configure IO-Link, EtherNet/IP™, and Modbus TCP settings for your IO-Link device• View real-time diagnostics for IO-Link, EtherNet/IP™, and Modbus TCP activity on your IO-Link ports• Load IODD (IO Device Description) files onto the IO-Link Master for your convenience• Configure IO-Link devices in minutes using the IO-Link Device– Port table (GUI) or the IO-Link Device

ISDU Interface, which provides ISDU (Indexed Service Data Unit) handling• Data Storage (automatic or manual) for Auto Device Configuration• IO-Link Device Validation (compatible and identical) to link specific IO-Link devices to a specific port• Data Validation (strict or loose) for data integrity

© 2018 by Comtrol Corporation. All Rights Reserved. Printed in the U.S.A. All trademarks used herein are the property of their respective trademark holders. Product specifications subject to change without notice. LT1534I

Email, FTP, and Web Support

[email protected]

ftp.comtrol.com

www.comtrol.com

Technical Support

+1.763.957.6000 www.comtrol.com/support

Sales Support

+1.763.957.6000 [email protected]

Warranty Information

Comtrol offers a 30-day satisfaction guarantee and

5-year limited warranty.