INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or...

12
INVINSA ® and INVINSA ® FR Application Instructions and Code Approvals

Transcript of INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or...

Page 1: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

INVINSA®

and INVINSA®

FRApplication Instructions and Code Approvals

Page 2: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives
Page 3: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

JM-Approved Fasteners

ENRGY 3® PolyisocyanurateRoof Insulation

JM PVC with DuPont™

Elvaloy® KEE, JM TPO or JM EPDM, Fully Adhered

Invinsa® or Invinsa® FR Roof Board,Mechanically Fastened

Deck

JM-Approved Fasteners

ENRGY 3® PolyisocyanurateRoof Insulation

JM-ApprovedFasteners

JM PVC with DuPont™

Elvaloy® KEE or JM TPOMechanically Fastened

Invinsa® or Invinsa® FR Roof Board,Mechanically Fastened

Deck

ENRGY 3® PolyisocyanurateRoof Insulation

Invinsa® Roof Board,Fully Adhered

DynaGrip Base SD/SA Base SheetDynaWeld Cap FR Cap Sheet

Deck

DeckExistingSingle Ply Roof

ExistingModified Bitumen Roof

Existing Built-Up Roof

Invinsa® Roof Board

ENRGY 3® PolyisocyanurateRoof Insulation

JM-Approved FastenersJM PVC with DuPont™

Elvaloy® KEE, JM TPO or JM EPDMRoofing Membrane

Single Ply Fully Adhered Systems

Single Ply Mechanically Fastened Systems

SBS Hybrid Systems

Various Roof Systems

New Construction and Re-Roof

New Construction and Re-Roof

New Construction and Re-Roof

Re-CoverJM-Approved Fasteners

Cold Application Adhesive

Deck

ENRGY 3®

PolyisocyanurateRoof Insulation

Invinsa® Roof Board JM Two-Part UrethaneInsulation Adhesive, JM Roofing System Urethane Adhesive, JM One-StepFoamable Adhesive

DynaGlas® FR CRCap Sheet

DynaBase® Base Sheet

SBS Cold Adhesive Applied

New Construction and Re-Roof

A Valuable Component to Your Roof SystemThe addition of Invinsa® or Invinsa® FR Roof Board to a single ply or SBS roof system increases the roof’s resistance to damage from various sources, including but not limited to hail, foot traffic, construction loads and normal roof maintenance. Invinsa is engineered as an integral part of the roof system, providing a protective layer for the insulation below and working with the membrane above to improve performance. Invinsa may be specified for new, re-roof and re-cover applications.

Product Advantages• High resistance to indentation, compression and crushing during

installation of the roof system and during periodic maintenance, once the roof is completed

• Rigidity to support the roof membrane

• Increased resistance to moisture absorption

• Dimensional stability

• Compatibility with PVC, TPO, EPDM and SBS roofing systems

• UL®, FM Global® and other important building agency approvals

JM TPO manufacturing facility in Scottsboro, AL

1

Page 4: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

Patterns for Mechanical Fastening

6"6"

12"

6"

12" 12"

24"

5 Fasteners/Board

5 Fasteners/Board

8 Fasteners/Board

12 Fasteners/Board 16 Fasteners/Board(1 per 2 ft2)

8 Fasteners/Board

36"

12" 12"3 Spaces @ 24"

12" 12"3 Spaces @ 24"

24"

24"

6"12"

6"

6"

6"

6"

18"

18"

6"

24"

6"

24"

Adhesive Patterns for Fully Adhering Invinsa Roof BoardTo adhere to ENRGY 3® using JM Roofing System Urethane Adhesive (RSUA), JM One-Step Foamable Adhesive, JM Two-Part Urethane Insulation Adhesive, JM Green Two-Part Urethane Insulation Adhesive and other adhesives.

1. Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern.

2. Follow instructions on respective adhesives with regard to application rates, open times, setting times and board weighting.

3. All ENRGY 3 boards run parallel to the 8' edge of a 4' x 8' Invinsa or Invinsa FR board with a 2' offset.

Note: For detailed information about perimeter and corner installation, please refer the fastening pattern UA-12 available on the JM Roofing website or in current JM Commercial/Industrial Roof Systems Manuals.

4' x 8' ENRGY 3 ® Roof Insulation Boards

(with 4' offset) 4' x 8' Invinsa ® or Invinsa ® FR Roof Boards

(with 2' offset to ENRGY 3)

2

Page 5: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

Standard Adhesive PatternFor all adhered Invinsa systems.

12"

12"

4"

4"

Adhesive Pattern Under Two 4' x 8' Invinsa ® or Invinsa ® FR Roof Boards

Adhesive Ribbons Set on 12" CentersEdge Ribbons Set on 6" Centers

12"

3"

3"

3"

5"

Heavy-Duty Adhesive PatternFor systems in which membrane wrinkling is a concern, including high deck non-uniformity and self-adhering membranes.

12"6" 6"

6"

Adhesive Pattern Under 4' x 8' Invinsa ® or Invinsa ® FR Roof Board

Adhesive Ribbons Set on 12" Centers

6"4' x 8' ENRGY 3® Roof Insulation

Note: For detailed information about perimeter and corner installation, please refer the fastening pattern UA-12 available on the JM Roofing website or in current JM Commercial/Industrial Roof Systems Manuals.

3

Page 6: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

4

FM Global® ApprovalsJM TPO Membrane Systems — Mechanically Fastened

Deck

Typ

e

Appl

icat

ion

Type

Deck

Gra

de1 (K

SI)

Roof

Nav

SM

Asse

mbl

y #1

Insu

latio

n2

Cove

r Boa

rd

Slop

e (#

”: 1

ft)

Mem

bran

e W

idth

(ft)

Mem

bran

e Pl

ate

Mem

bran

e Fa

sten

er

Mem

bran

e Fa

sten

er

Spac

ing

(#“

OC)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Stee

l

N

80, 33247419-0-0

E3

I FR 1.510'

HL HL

12"

60

1 A SH

341166-0-0 I 1

80222741-0-0 I FR 1.5

8'75

341114-0-0 I 1

80, 33222809-0-0 I FR 1.5

XHL XHL 90341117-0-0 I 1

80222820-0-0 I FR 1.5

10'341120-0-0 I 1

80, 33

222859-0-0 I FR 1.5

HL HL 6"

90341123-0-0 I 1222814-0-0 I FR 1.5

8' 120341118-0-0 I 1222952-0-0 I FR 1.5

5' 165341138-0-0 I 1

FM Global® ApprovalsJM TPO Membrane Systems — RhinoPlate Systems*

Deck

Typ

e

Appl

icat

ion

Type

Deck

Gra

de1 (K

SI)

Roof

Nav

SM

Asse

mbl

y #1

Insu

latio

n2

Cove

r Boa

rd

Slop

e (#

”: 1

ft)

Mem

bran

e W

idth

(ft)

Mem

bran

e Pl

ate

Mem

bran

e Fa

sten

er

Fast

ener

Spa

cing

(#

: ft2 )

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Stee

l

N33

247612-0-0

E3

I FR 1.5

10' RhP HL

1:5.33 90

1 A SH

341170-0-0 I 1247628-0-0 I FR 1.5

1:4 135341174-0-0 I 1

80, 33249582-0-0 I FR 1.5

6" OC 210341186-0-0 I 1

* The plates and fasteners are applied through the insulation boards and then bonded to the underside of the membrane.

FM Global® ApprovalsJM TPO — Fastened Cover Board, Fully Adhered Membrane

Deck

Type

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #1

Insu

latio

n2

Cove

r Boa

rd

Cove

r Boa

rd

Fast

ener

Cove

r Boa

rd

Fast

ener

Rat

e (#

: ft2 )

Mem

bran

e

Mem

bran

e Ad

hesi

ve

Slop

e (#

”: 1

ft)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Spec

ial

Cons

ider

atio

ns

Stee

l

RC 317599-0-0

E3

I

UF 1:2

TSB 0.25

90 1 A SH *

N

327590-0-0

I, I FR

327593-0-0 LVOC 0.5361269-0-0 FB

WB 0.75361273-0-0

T

RC

327596-0-0 LVOC0.5

354045-0-0 XFB

WB361270-0-0E3 0.75

361274-0-0 T* Optional SR Thermal Barrier included in the assembly.

Notes1. Deck Grade and assemblies vary. Please check RoofNavSM for specific deck constructions of individual approvals.2. All E3 insulation for new roofs is 1.5" min unless otherwise listed. Re-Cover insulation thickness varies by approval. Please check individual listings.

This is intended to serve as a reference guide, please check RoofNav for the most current information and assembly details.FM Global and RoofNav are among the trademarks or registered trademarks of Factory Mutual Insurance Company and FM Approvals LLC, respectively.

Insulation/Cover BoardE3 = ENRGY 3® I = Invinsa® Roof Board I FR = Invinsa® FR Roof Board X = No Insulation

Application TypeN = New Roof RC = Re-Cover

Fastener and PlateHL = High Load RhP = RhinoPlate™

UF = UltraFast®

XHL = Extra High Load

MembraneFB = JM TPO Fleece Backed T = JM TPO

AdhesiveLVOC = JM Low VOC SB = JM Solvent Based WB = JM Water Based

Page 7: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

5

FM Global® ApprovalsJM TPO — Fastened Insulation, Subsequent Layers Fully Adhered

Deck

Type

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #1

Insu

latio

n2

Insu

latio

n Fa

sten

er

Insu

latio

n Fa

sten

er R

ate

(#: f

t2 )

Cove

r Boa

rd

Cove

r Boa

rd

Adhe

sive

3

Cove

r Boa

rd

Adhe

sive

Rat

e (ri

bbon

s: #

” OC

)

Mem

bran

e

Mem

bran

e Ad

hesi

ve

Slop

e (#

”: 1

ft)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Stee

l

N

234926-0-0

E3 UF1:4

I 2P UIA 12"T

SB 0.25

751 A SH

234930-0-0 LVOC 0.5361246-0-0

WB 0.75361252-0-0

FB339704-0-0 1:1 RSUA 0.5 135

FM Global® ApprovalsJM TPO — Fastened Thermal Barrier, Fully Adhered Insulation, Cover Board, and Membrane

Deck

Type

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #1

Ther

mal

Bar

rier

Ther

mal

Bar

rier

Fast

ener

Ther

mal

Bar

rier

Fast

ener

Rat

e (#

: ft2 )

Vapo

r Bar

rier

Insu

latio

n2

Insu

latio

n Ad

hesi

ve3

Insu

latio

n Ad

hesi

ve

Rate

(rib

bons

: #”

OC)

Cove

r Boa

rd

Cove

r Boa

rd

Adhe

sive

3

Cove

r Boa

rd

Adhe

sive

Rat

e (ri

bbon

s: #

” OC

)

Mem

bran

e

Mem

bran

e Ad

hesi

ve

Slop

e (#

”: 1

ft)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Stee

l

N361275-0-0

SR(min 0.625")

UF 1:4 VB SA E3 2P UIA 12" I 2P UIA 12"T

WB 0.7590 1 A SH361278-0-0 FB

353883-0-0 T SB, WB 0.5

FM Global® ApprovalsJM TPO — Fully Adhered Insulation, Cover Board and Membrane

Deck

Typ

e

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #1

Vapo

r Bar

rier

Insu

latio

n2

Insu

latio

n Ad

hesi

ve3

Insu

latio

n Ad

hesi

ve R

ate

(ribb

ons:

#”

OC)

Cove

r Boa

rd

Cove

r boa

rd

Adhe

sive

3

Cove

r Boa

rd

Adhe

sive

Rat

e (ri

bbon

s: #

” OC

)

Mem

bran

e

Mem

bran

e Ad

hesi

ve

Slop

e (#

”: 1

ft)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Stru

ctur

al

Conc

rete

N

361264-0-0361263-0-0 DG

E32P UIA

12" I2P UIA

12"

TWB 0.75

210

NC A SHFB

360219536-0-0

XSB, WB 0.5

360361249-0-0 WB 0.75339727-0-0 2P UIA, RSUA 2P UIA, RSUA RSUA 0.5 135

Notes

1. Assemblies vary. Please check RoofNavSM for specific deck constructions of individual approvals.2. Some assemblies require a 2" weld. Check specific assemblies.3. All E3 insulation for new roofs is 1.5" min unless otherwise listed. Re-Cover insulation thickness varies by approval. Please check individual listings.4. Other adhesives may be available in the referenced approvals. Please check listing for all adhesive options.

This is intended to serve as a reference guide, please check RoofNav for the most current information and assembly details.FM Global, RoofNav and Securock are among the trademarks or registered trademarks of Factory Mutual Insurance Company, FM Approvals LLC and Georgia-Pacific LLC, respectively.

Insulation/Cover BoardE3 = ENRGY 3® I = Invinsa® Roof Board

Thermal/Vapor BarrierDG = DynaGrip Base SD/SA SR = Securock® Gypsum Fiber VB SA = JM Vapor Barrier SA X = No Vapor Barrier

Application TypeN = New Roof

Fastener and PlateUF = UltraFast®

MembraneFB = JM TPO Fleece Backed T = JM TPO

Insulation/Cover Board Adhesive2P UIA = JM Two-Part Urethane Insulation Adhesive

AdhesiveLVOC = JM Low VOC 2P UIA = JM Two-Part Urethane RSUA = JM Roofing System Urethane Adhesive SB = JM Solvent Based WB = JM Water Based

Page 8: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

6

FM Global® ApprovalsJM PVC & JM PVC SD Plus — Mechanically Fastened Membrane

Deck

Typ

e

Appl

icat

ion

Type

Deck

Gra

de1 (K

SI)

Roof

Nav

SM

Asse

mbl

y #1

Insu

latio

n2

Cove

r Boa

rd

Slop

e (#

”: 1

ft)

Mem

bran

e

Mem

bran

e W

idth

(ft)

Mem

bran

e Pl

ate

Mem

bran

e Fa

sten

er

Mem

bran

e Fa

sten

er

Spac

ing

(#“

OC)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Spec

ial C

ondi

tions

Stee

l

N

80 210448-0-0

E3 I 1

JM PVC

6.5'HL HL

6"150

1

A

SH

*’ **

33359040-0-0

JM PVC, SD Plus 90B

172969-0-0A

80210446-0-0 JM PVC 12" 105

**366308-0-0 JM PVC, SD Plus 6" 9010' B* Assembly has an air barrier. All assemblies with air barrier have insulation fastening rate of 1 fastener per 2 square feet.** Laps sealed with 2" wide weld.

FM Global® ApprovalsJM PVC & JM PVC SD Plus — RhinoPlate Systems*

Deck

Type

Appl

icat

ion

Type

Deck

Gra

de1 (K

SI)

Roof

Nav

SM

Asse

mbl

y #1

Insu

latio

n2

Cove

r Boa

rd

Slop

e (#

”: 1

ft)

Mem

bran

e

Mem

bran

e W

idth

(ft)

Mem

bran

e Pl

ate

Mem

bran

e Fa

sten

er

Fast

ener

Spa

cing

(#

: ft2

)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Stee

l

N 33247656-0-0

E3 I 1 JM PVC,SD Plus 10' RhP HL

1:5.33 901 A SH

247668-0-0 1:4 135

* The plates and fasteners are applied through the insulation boards and then bonded to the underside of the membrane.

FM Global® ApprovalsJM PVC — Fastened Cover Board, Fully Adhered Membrane1

Deck

Typ

e

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #2

Insu

latio

n3

Cove

r Boa

rd

Cove

r boa

rd F

aste

ner

Cove

r Boa

rd

Fast

ener

Rat

e (#

: ft2 )

Mem

bran

e Ad

hesi

ve

Slop

e (#

”: 1

ft)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Stee

l RC 354042-0-0 X I UF 1:2 SB, LVOC 1 90 1 A SHN 318004-0-0

E3RC 318014-0-0

Notes:1. Deck Grade and assemblies vary. Please check RoofNavSM for specific deck constructions of individual approvals.2. Insulation thickness requirements vary for re-cover construction. Check specific RoofNav numbers. All E3 insulation for new roofs is 1.5" min unless otherwise listed. Re-Cover insulation thickness varies by approval. Please check individual listings.3. Other adhesives may be available in the referenced approvals. Check application rate for all approvals listing hot asphalt (HA) as an adhesive. Please check listing for all adhesive options

This is intended to serve as a reference guide, please check RoofNav for the most current information and assembly details.FM Global and RoofNav are among the trademarks or registered trademarks of Factory Mutual Insurance Company and FM Approvals LLC, respectively.

Insulation/Cover BoardE3 = ENRGY 3® I = Invinsa® Roof Board X = No Insulation

Application TypeN = New Roof RC = Re-Cover

Fastener and PlateHL = High Load RhP = RhinoPlate™

UF = UltraFast®

AdhesiveLVOC = JM Low VOCSB = JM Solvent Based

Page 9: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

7

Notes1. Deck Grade and assemblies vary. Please check RoofNavSM for specific deck constructions of individual approvals.2. All E3 insulation for new roofs is 1.5" min unless otherwise listed. Re-Cover insulation thickness varies by approval. Please check individual listings.

This is intended to serve as a reference guide, please check RoofNav for the most current information and assembly details.FM Global and RoofNav are among the trademarks or registered trademarks of Factory Mutual Insurance Company and FM Approvals LLC, respectively.

FM Global® ApprovalsJM PVC — Fastened Insulation with Subsequent Layers Fully Adhered1

Deck

Type

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #2

Insu

latio

n3

Insu

latio

n Fa

sten

er

Insu

latio

n Fa

sten

er R

ate

(#: f

t2 )

Cove

r Boa

rd

Cove

r boa

rd A

dhes

ive4

Cove

r Boa

rd A

dhes

ive

Rate

(rib

bons

: #”

OC)

Mem

bran

e Ad

hesi

ve

Slop

e (#

”:1

ft)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Stee

l

N268259-0-0 E3 (min 2")

UF1:4

I 2P UIA 12" LVOC, SB 1 90 1 A SH268260-0-0 E3 1:2

FM Global® ApprovalsJM PVC — Fully Adhered Insulation, Cover Board and Membrane1

Deck

Typ

e

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #

Vapo

r Bar

rier

Insu

latio

n2

Insu

latio

n Ad

hesi

vee3

Insu

latio

n Ad

hesi

ve

Rate

(rib

bons

: #”

OC)

Cove

r Boa

rd

Cove

r Boa

rd

Adhe

sive

4

Cove

r Boa

rd A

dhes

ive

Rate

(rib

bons

: #”

OC)

Mem

bran

e Ad

hesi

ve

Slop

e (#

”: 1

ft)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(C

lass

)

Exte

rnal

Fire

(C

lass

)

Hail

Ratin

g

Stru

ctur

al C

oncr

ete

N184081-0-0 2 ply GP or GPP

E3

MBR BA 1.5 gal/sq

I

MBR BA

12"

WB

1

225

NC A SH

227693-0-0

X

2P UIA

12"

2P UIAWB, LVOC

210RC 228669-0-0N 227694-0-0

UIA UIA 150RC 228671-0-0

N

232113-0-0

2P UIA

2P UIASB, WB,

LVOC 210279362-0-0

DG279382-0-0279375-0-0

WB, LVOC279379-0-0 UIA 150279393-0-0

APP2P UIA

SB, WB, LVOC 210279429-0-0

279418-0-0WB, LVOC

279419-0-0 UIA 150

FM Global® ApprovalsJM EPDM — Fastened Cover Board, Fully Adhered Membrane

Deck

Type

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #

Insu

latio

n

Cove

r Boa

rd

Cove

r Boa

rd

Fast

ener

Cove

r Boa

rd

Fast

ener

Rat

e (#

: ft2 )

Mem

bran

e Ad

hesi

ve

Slop

e (#

”: 1

ft)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(Cla

ss)

Exte

rnal

Fire

(Cla

ss)

Hail

Ratin

g

Stee

l

N 339378-0-0 E3I

UF 1:2 LVOC, SB, WB 1

90

1 A SHRC

354081-0-0X

354034-0-060N 300835-0-0

E3 I, I FRRC 300840-0-0

Insulation/Cover BoardE3 = ENRGY 3® I = Invinsa® Roof Board I FR = Invinsa® FR X = No Insulation

Vapor BarrierAPP = JM APP Base DG = DynaGrip Base SD/SA GP = GlasPly® IV GPP = GlasPly® Premier X = No Vapor Barrier

Application TypeN = New Roof RC = Re-Cover

Fastener and PlateHL = High Load RhP = RhinoPlate™

UF = UltraFast®

XHL = Extra High Load

Insulation/Cover Board AdhesiveMBR BA = MBR® Bonding Adhesive 2P UIA = JM Two-Part Urethane Insulation Adhesive UIA = JM Urethane Insulation Adhesive

AdhesiveLVOC = JM Low VOC MBR BA = MBR® Bonding Adhesive 2P UIA = JM Two-Part Urethane SB = JM Solvent Based UIA = JM Urethane Insulation Adhesive WB = JM Water Based

Page 10: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

FM Global® Approvals JM SBS Systems — Cold Adhesive Applied

Deck

Typ

e

FM R

atin

g

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #

Slop

e

ENRGY 3 Insulation Invinsa Roof Board Membrane

Not

es

Thic

knes

s,

min

.

Atta

chm

ent

Atta

chm

ent

Rate

Atta

chm

ent

Rate

Stee

l

1A-90 N

144245-144211-0

0.5 (42) 1.5" (38 mm) LL

UF/UF

16/board - 1 per 2 ft2 (0.19 m2) CAA 2 gal/100 ft2

(8.15 l/m2)

2-Ply (CAA)

144245-144212-0 3-Ply (CAA)

144245-144213-0 4-Ply (CAA)

Conc

rete 144247-144211-0

AP/UF

2-Ply (CAA)

144247-144212-0 3-Ply (CAA)

144247-144213-0 4-Ply (CAA)

8

FM Global® ApprovalsJM EPDM — Fastened Insulation with Subsequent Layers Fully Adhered

Deck

Typ

e

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #

Insu

latio

n

Insu

latio

nFa

sten

er

Insu

latio

n Fa

sten

er R

ate

(#

: ft2 )

Cove

r Boa

rd

Cove

r Boa

rd

Adhe

sive

Cove

r Boa

rd

Adhe

sive

Rat

e (#

“ OC

)

Mem

bran

e Ad

hesi

ve

Slop

e (#

”: 1

ft)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(Cla

ss)

Exte

rnal

Fire

(Cla

ss)

Hail

Ratin

g

Cem

entit

ious

W

ood

Fibe

r

N368880-0-0

E3Gyptec 1:2

I 2P UIA, HA 12" LVOC, SB, WB 160

1 A SH368881-0-0 2P UIA, HA 12" * 90

* Asphaltic Base Sheet attached with Olylok 9" OC in the lap and two staggered rows of 18" OC.

FM Global® ApprovalsJM EPDM R — Mechanically Fastened Membrane

Deck

Typ

e

Appl

icat

ion

Type

Deck

Gra

de1 (K

SI)

Roof

Nav

SM

Asse

mbl

y #

Insu

latio

n2

Cove

r Boa

rd

Slop

e (#

”: 1

ft)

Mem

bran

e W

idth

(ft)

Mem

bran

e Fa

sten

er

Mem

bran

e Fa

sten

er

Spac

ing

(#“

OC)

Win

d Up

lift

(PSF

)

Inte

rnal

Fire

(Cla

ss)

Exte

rnal

Fire

(Cla

ss)

Hail

Ratin

g

Stee

l

N 80

317960-0-0

E3 I, I FR 1 10'

HL

6"

90

1 A SH

324306-0-0 HL (w/RPS)317964-0-0 HL

75324310-0-0

HL (w/RPS)RC 33

325085-0-0 105324312-0-0 90324316-0-0 75

Notes1. Deck Grade and assemblies vary. Please check RoofNav for specific deck constructions of individual approvals.2. All E3 insulation for new roofs is 1.5" min unless otherwise listed. Re-Cover insulation thickness varies by approval. Please check individual listings.3. Other urethane adhesives may be available in the referenced approvals. Check application rate for all approvals listing hot asphalt (HA) as an adhesive. Please check listing for all adhesive options.

This is intended to serve as a reference guide, please check RoofNav for the most current information and assembly details.FM Global and RoofNav are among the trademarks or registered trademarks of Factory Mutual Insurance Company and FM Approvals LLC, respectively.

Insulation/Cover BoardE3 = ENRGY 3® I = Invinsa® Roof Board I FR = Invinsa® FR Roof Board LL = Loose Laid

Application TypeN = New Roof RC = Re-Cover

Fastener and PlateAP = All Purpose HL = High Load®

RPS = Reinforced Perimeter Strip UF = UltraFast®

Insulation/Cover Board AdhesiveHA = Hot Asphalt2P UIA = JM Two-Part Urethane Insulation Adhesive

Membrane AdhesiveCAA = JM Cold Application AdhesiveLVOC = JM Low VOC SB = JM Solvent Based WB = JM Water Based

Page 11: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

Deck

Typ

e

FM

Ratin

g

Appl

icat

ion

Type

Roof

Nav

SM

Asse

mbl

y #

Slop

e

ENRGY 3 Insulation Invinsa Roof Board Membrane

Not

es

Thic

knes

s,

min

.

Atta

chm

ent

Rate

Atta

chm

ent

Rate

Atta

chm

ent

Stee

l 1A-90

N

262904-137159-01 (83)

1.5" (38 mm)LL – UF/UF plastic

16/board - 1 per 2 ft2 (0.19 m2)

Self-Adhering

2-Ply (HW)1A-165 262905-137159-0 2" (51 mm) 32/board - 1 per 1 ft2

(0.09 m2)

Conc

rete

NC A-210 162901-77921-0

0.75 (63)1.5" (38 mm)

UIA 0.75" (19 mm) @ 12" (31 cm)

o.c.

UIA, MBR BA 0.75" (19 mm) @ 12" (31 cm) o.c. 2-Ply (SA)

NC A-225162904-77921-0 UIA, 2P UIA

MBR BA 1.5 gal/100 ft2 (6.04 l/m2)RC 162907-77921-0 – – – ALL, 2-Ply

(SA)

FM Global® Approvals JM SBS Systems — Self-Adhering

Deck

Typ

e

Appl

icat

ion

Type

Clas

s

Max

. Slo

pe

in./f

t (m

m/m

)

Insu

latio

n

Cove

r Boa

rd

Mem

bran

e

Atta

chm

ent

Met

hod

UL N

umbe

r*

Non

com

bust

ible

N

A

1 (83)

E3 (Optional)

I

JM EPDM

Fully Adhered

EPDM-42

2 (167)EPDM-43

JM PVC FB PVC-18

1 (83)JM PVC

PVC-28

2 (167) Mechanically Fastened PVC-36

0.5 (42) JM TPO

Fully Adhered TPO-17

1 (83)Mechanically Fastened

TPO-33

0.5 (42)

JM SBS

SBS-Hot-9

Self-Adhering SBS-Hot-39

Fully Adhered SBS-Cold-3

Com

bust

ible

JM BUR Mechanically Fastened BUR-14

I FR**

JM TPO

Fully Adhered TPO-11,12

1 (83)Mechanically Fastened

TPO-21

B 2 (167) TPO-2

A

0.5 (42) JM TPO FBFully Adhered

TPO-15,18

1 (83)JM PVC

PVC-4

2 (167)

Mechanically Fastened PVC-7

JM PVC FBFully Adhered

PVC-34

JM PVC SDPVC-21,27

Mechanically Fastened PVC-13

0.75 (63)

JM EPDM RFully Adhered

EPDM-47

1 (83) EPDM-50

0.75 (63) Mechanically Fastened EPDM-14

2 (167)JM EPDM NR or FR Fully Adhered

EPDM-43

1 (83) EPDM-52

UL® External Fire Resistance (UL 790) Major Approvals — Invinsa Roof Board — New Construction

For more detailed application or code and approval information, please contact your JM representative or call us at (800) 922-5922.FM Global and RoofNav are among the trademarks or registered trademarks of Factory Mutual Insurance Company and FM Approvals LLC, respectively.

* UL Number refers to constructions (paragraph) in JM’s UL 790 listing.

9

Application TypeN = New Roof RC = Re-Cover

Adhesive 2P UIA = JM Two-Part Urethane Insulation Adhesive UIA = JM Urethane Insulation Adhesive MBR BA = MBR Bonding Adhesive

Fasteners and Plates UF = UltraFast® RhP = RhinoPlate®

Membrane Adhesive LL = Loose Laid

Membrane NotesPVC FB = Fleece-Backed PVC MP = Any Multi-Ply Cover (existing roof) ALL = Any Membrane Cover (existing roof) HW = Heat Weld SA = Self-Adhering SP = Any Single Ply Cover (existing roof)

Insulation/Cover BoardE3 = ENRGY 3®

** A minimum 1/4" thick layer of “Invinsa® FR” can be used in lieu of “Invinsa®” in any existing non-combustible deck Classification. This can be above or below additional insulation layers described in the Certified roofing system. The resulting roofing assembly can be used over a combustible roof deck (minimum 15/32" plywood). All insulation joints must be staggered a minimum of 6" from the deck joints and from the insulation joints directly below. The maximum incline shall be in accordance with the Certification established for the original roofing system as listed in UL’s Roofing Materials & Systems Directory; however the incline cannot exceed 3:12.In cases where Invinsa or Invinsa FR is not specifically called out in an assembly the following applies per TGFU.R10167: “Invinsa®” may be used over “ENRGY 3®”, or as an acceptable alternate to “ENRGY 3®”, in any of the following Classifications.

Page 12: INVINSA and INVINSA FR - Johns Manville · Apply adhesive to the ENRGY 3 layer and set Invinsa or Invinsa FR on top of adhesive pattern. 2. Follow instructions on respective adhesives

RS-5503 11-15 (Replaces 8-14)

717 17th St.Denver, CO 80202(800) 922-5922www.jm.com/roofing

To ensure quality workmanship and top-notch installation, JM offers its Peak Advantage Contractor Program. Contractors selected to participate are proven to be best in class, having lived up to the highest performance standards. These contractors have access to JM’s strongest guarantees. To be assured of the best possible results on the roofing system you specify, make sure it’s installed by a JM Peak Advantage Contractor.

Johns Manville designs roofing products that work together to provide a one-source comprehensive roofing system solution. Total roofing system guarantees are available under the JM Peak Advantage Guarantee program. To learn more about our standard guarantee terms and conditions or talk to your local JM sales representative.

JM Peak Advantage Guarantees are available only on qualified JM roofing systems containing JM roofing products. JM standard product terms and conditions will apply to include a one-year limited product warranty.

Product Warranties

Peak Advantage Contractor Program