AIR TO WATER HEAT PUMPS
35ºCA++
55ºCA+
A Q U A P U R A
H E A T I N G & C O O L I N G
EVI + INVERTER MODELS. REPLACE YOUR OIL / GAS BOILER. IDEAL FOR UNDERFLOOR HEATING SUITABLE FOR HEATING BOTH RADIATORS AND DOMESTIC HOT WATER COOLING ALSO A POSSIBILITY
W W W . L V P R E N E W A B L E S . I E
![Page 2: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/2.jpg)
02 ENERGIE
HIGHLY EFFICIENTAIR TO WATER HEAT PUMPTHAT OFFER BOTH HEATINGAND HOT WATERSOLUTIONS
H O T W A T E R
OUR HEAT PUMPSOLUTIONSOFFER:. High efficiency with maximum
comfort. Reduction in the household bills
whilst never compromising the
comfort. Improved BER Rating. Easy to maintain. Aesthetically pleasing
35ºCA++
55ºCA+
I I I
A++ A++
A+
A B C D E F G
35 °C
YZ
YZ
YZ kW
YZ kW
YZ kW
2015 XYZ/2013
YZ
YZ
A+
kW
YZYZ
dBYZ
dBYZ
YZYZkW
55 °C
![Page 3: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/3.jpg)
CE
NT
RA
L
HE
AT
IN
G
GREATER HEAT PRODUCTION WITH LESS ENERGYCONSUMPTION
The environment’s heat is commonly attributed to indirect solar energy, stored in water, air and soil. The heat pump will remove heat from these heat sources to, later, be used for heating your home. The highly efficient EVI and INVERTER Air to Water heat pumps are a modern, efficient and clean solution that guarantee your home’s comfort, while considering the environment.
A smart way to use Nature'sresources in order to improveyour quality of life. With thissolution you will be making a
CE
NT
RA
L
HE
AT
IN
G
GREATER HEAT PRODUCTION WITH LESS ENERGYCONSUMPTION
serious commitment to the reduction of harmful emissions into our atmosphere, thus contributing to the planet's green agenda.
The EVI and INVERTER Air to water heat pumps have been developed to meet both domestic and industrial needs, for heating, cooling and Domes-tic Hot Water solutions (DHW).
![Page 4: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/4.jpg)
04 ENERGIE
THE RANGE OF AQUAPURAHEAT PUMPS INCLUDE 8 TO 17kW MODELS
V E N T C O N V E C T O R S
COMPONENTS BRANDS
KEY FEATURES. Heating and/or Cooling. Reduced Maintenance and low operating noise. Operating with external temperatures down to – 25°C. Construction with anodized coating resistant to natural corrosion. Domestic Hot Water Function
![Page 5: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/5.jpg)
UP TO 65OCWATER
TEMPERATURE
4.4COP
-25OCOUTDOOR
TEMPERATURE
UP TO 55OCWATER
TEMPERATURE
4.1COP
-25OCOUTDOOR
TEMPERATURE
EVI TECHNOLOGY
The EVI SCROLL optimized steam injection technology confers a
higher efficiency to conventional SCROLL technology. This is
achieved with an intermediate steam injection during the
compression cycle thus reducing the high working frequency of
the compressors, allowing an increase of the heat production
capacity with lower energy consumption.
Th
erm
al O
utp
ut
Operating PeriodEVI VS TRADITIONAL
DC INVERTER TECHNOLOGY
The DC INVERTER technology differs from some other existingtechnologies in the market since it possesses compressors with the capacity to vary the frequency of operation according to the exact comfort needs of the house HVAC. There is therefore lower energy consumption.
T
herm
al O
utp
ut
Operating PeriodINVERTER VS TRADITIONAL
05ENERGIE
![Page 6: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/6.jpg)
06 ENERGIE
HEAT PUMPS THAT GIVE YOUR HOME MORE COMFORT AND EFFICIENCY
35ºCA++
55ºCA+
AQUAPURA INVERTER. The ideal heat pump for underfloor heating. Efficient and silent solution. Attractive and compact design. INVERTER technology. Heat pump with the capability to heat DHW. Facilitates heating and cooling in certain situations
L O W C O N S U M P T I O N
![Page 7: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/7.jpg)
S A V I N G S
AQUAPURA EVI. Integrated Comfort solution, heating,
cooling and production of Domestic Hot
Water (DHW). Substitute your boiler for this high
temperature heat pump.. Keep the existing radiators. Attractive and compact Design. EVI SCROLL technology. Heat pump with a facility for DHW. Allows heating and cooling
07ENERGIE
UN
DE
RF
LO
OR
H
EA
TI
NG
![Page 8: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/8.jpg)
08 ENERGIE
FUNCTIONING PRINCIPLE
EVAPORATOR>>>>
CO
MP
RE
SO
R
EX
PA
NS
ION
VA
LV
E
<<<< CONDENSER
1. A refrigerant cooling fluid ispumped to the
evaporator.
2. Where it turns fromliquid to gaseous through
the external heatexchanger.
3. The refrigerantis sucked into
the compressor.
5. The heat is transferredto the home´s heating
system through theinternal heat exchanger.
6. The refrigerantturns into liquid again
and the pressuredrops.
4. Where it iscompressed,
increasing thetemperature.
1
6
2 3
4
5
AIR INTAKETHE ENVIRONMENT
ELECTRICITY 25% 7
5% TH
ER
MA
L E
NE
RG
Y
There is a refrigerant that is pumped to an outdoor heat exchanger (evaporator). The refrigerant, with the help of a fan, absorbs the energy from the atmosphere to the temperature differential obtained outdoors. During this process, the liquid changes to a gaseous state. The gaseous state is sucked in by the mechanical part of the system, the compressor where it is compressed. The pressure goes up and, consequently, the liquid temperature increases. After that, the liquid travels to a second inside heat exchanger (condenser) and transfers heat to the water in the cylinder. The fluid goes into liquid state by cooling down. The liquid pressure is reduced due to a strangulation that happens in the expansion valve and the process starts again.
![Page 9: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/9.jpg)
05ENERGIE
PRIMARY ENERGY CONSUMPTION
THE EVI AND INVERTER HEAT PUMPS STAND OUT FOR THEIR HIGH PERFORMANCE
C O M F O R T
ENERGY CONSUPTION GRAPHIC
Heating oil
Natural gas
Propane gas (GPL)
Heat pumps
The heat pumps are capable of heating and cooling as well as domestic water heating. Those solutions stand out for their high energey efficiency, they can reach an energy classification up to A++ for heating. They also stand out for their ease of integration with other heating systems and easy installation.
![Page 10: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/10.jpg)
THE PRESENCE OF AN BUFFER TANK IN THE INSTALLATION GUARANTEES SEVERAL ADVANTAGES:. Energy-saving . Available thermal outputs increase. Smaller operating periods
CYLINDERS TO PRODUCE DOMESTIC HOT WATER (DHW):. Capacities of 200, 250, 300 and 500 litres. Stainless steel tub AISI 444. 5 year guarantee
W E L L - B E I N G
HEATPUMP FOR HOT WATER ONLY HEAT PUMP FOR HEATING AND HOT WATER WITHOUT BUFFER
HEAT PUMP FOR HEATING AND HOT WATER WITH BUFFER
HEATPUMP FOR HEATING WITH BUFFER
![Page 11: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/11.jpg)
FF Evi 15230V
FF Evi 10230V
Features FF Evi 17400V
FF Evi 15400SB
INVERTER 8/12230V
*Electrical consumption: environment temperature (DB/WB): 7°C/6°C, water temperature (In /Out): 30°C/35°C
**Refrigerated power: environment temperature (DB/WB): 35°C/24°C, water temperature (In/Out): 23°C/18°C
***Average climate (-10°C)
1
1
kW
kW
W/W
kW
kW
W/W
V/Hz
kW
No
/
No
/
mm
mm
dB
oC
kW
%
/
14.50
3.40
4.26
12.70
3.74
3.40
230V~/50Hz
3
2
1
EVI Scroll
Yes
66
35
14.50
135
1364/1180/450
13751255/550
A+
17.00
4.00
4.25
15.36
4.52
3.40
400V~/50Hz
3
2
1
EVI Scroll
Yes
68
35
17.00
137
1364/1180/450
1375/1255/550
A+
9.20
2.24
4.10
7.68
2.48
3.10
230V~/50Hz
3
1
1
EVI Scroll
Yes
62
35
9.20
135
1160/845/424
1200/880/480
A+
15.10
3.30
4.58
14.70
4.10
3.58
400V~/50Hz
-
2
1
Scroll
No
66
35
15.10
151
1364/1180/450
13751255/550
A++
4.20~12.30
0.80~3. 20
4.21
2.80~10.00
1.00~3.40
3.57
230V~/50Hz
3
Rotary
Yes
68
35
8.52
152
960/910/440
1010/920/470
A++
*Heat output
*COP
**Refrigerated Power
**EER
Supply
Compressors
Kind of compressor
Electric immersion
Integrated circulation pump
Fans
Liquid dimensions (L /A /P)
Packed dimensions (L /A /P)
Optimum power output
Electric efficiency
*Electrical consumption
**Electric power
Noise level (outer unit)
***ErP
Efficiency energy-class
TECHNICAL FEATURES
11ENERGIE
![Page 12: INVERTER MODELS - Thermodynamic Solar Panels€¦ · A I R I NTAKE T H E E N V I RON M N E L E C T R I C I T Y 2 5 % 7 5 % T H E R M A L E N E R G Y There is a refrigerant that is](https://reader033.fdocuments.in/reader033/viewer/2022050212/5f5e49122fcab9362b067ca4/html5/thumbnails/12.jpg)
This brochure was only made to inform and it doesn’t constitute a contractual o�er to LVP Renewables Ltd. LVP Renewables compiled the content of this brochure using its best knowledge. It is not giving any guarantee expressed or implied with regards to the totality, precision, reliability or suitability to a certain end of the substance and of the products and services preented. The speci�cations are subject to change without notice. LVP Renewbles Ltd explicitly rejects any direct or indirect damages, in it’s broadest sense, result or related with the use and/or interpretation of this brochure.
Unit D2 North City Business ParkFinglas, Dublin 11, Ireland.