Inventure Generic Rbi Presentation

7
Inventure technologies: from office to operation RBI and inspection services – RBI Training Strong focus on implementation Multi-disciplinary services Track record: Shell Pernis, ENI Marghera, Vopak Europoort, Oiltanking, ConocoPhillips, BP Sangachal, Total Antwerpen Also EEMUA 159 and API 581 appendix O for storage tanks

description

a short presentation on our company and what we do...

Transcript of Inventure Generic Rbi Presentation

Page 1: Inventure Generic Rbi Presentation

Inventure technologies: from office to operation

RBI and inspection services – RBI Training

Strong focus on implementation

Multi-disciplinary services

Track record: Shell Pernis, ENI Marghera, Vopak Europoort, Oiltanking, ConocoPhillips, BP Sangachal, Total Antwerpen

Also EEMUA 159 and API 581 appendix O for storage tanks

Page 2: Inventure Generic Rbi Presentation

RBI ReviewFacilitation

Create RBI based

inspection plans

RBI

INSPECTIONS

NDT

Gathering field dataCoordinate RBI based NDT

RBI adjustment

Process dataFormulate practical inspection plan

From Operation to Office

From Office to Operation

Page 3: Inventure Generic Rbi Presentation

RBI (Review)

Startup / shutdown conditions / Plant changes

Based on mimimal essential involvement

Plan kick-off to get commitment from workshop members

Break down in smaller workshops

Make and keep up action list

Relevant information handy

More focus on IOW

CUI assessments

Page 4: Inventure Generic Rbi Presentation

RBI (Facilitating)

Materials, temperatures, pressures

SAP dump

As-built drawings

Strength calculations

Piping Classes

Plant manuals

Corrosion allowances

Remaining lifetime

Page 5: Inventure Generic Rbi Presentation

Inspection planning

Page 6: Inventure Generic Rbi Presentation

NDT coordination

Prepare workpacks with correct material, temperature, etc

Prepare inspection isometrics

Process data

(Historical) NDT, RT and inspection data

Trending?

Correct method for material / degradation mechanism?

high acuracy low acuracyA 8,3 0,3B 5,4 0,2

Vessel Nr.

OBSERVATIONSIP1, No corrosion Evident.Min wall thickness 5.4 mm.

Plate Size 14"x17"

Object diameter

2" and 3"

RADIOGRAPHY SETUP MEASUREMENT SETUPSource Ir 192

Strength 9.5 Ci

Exposure time

240 sec

Crew N.M. Goudriaan To check wall thickness measurements and inspect for any corrosion. A. Steel

8-Y-3725Drawing Nr. ELP-S37-PPI-20241-002

Raw Data Viewer Rhythm Review 2.0i

IP1

GENERAL INFORMATION INTEREST MEASUREMENTS [mm]

= Point of focus

5 cm

A

B

A15 cm

B1

FFD

12

6

D

Page 7: Inventure Generic Rbi Presentation

Closing the loop advantages

Creating ownership

Graspable results

Commitment from workshop team

Less inspection schedules

Money savings in streamlined inspection plan

Stronger focus on real trending

More focus on non-trendable degradation like cracking

Input for Integrity Operating Window