Page 1: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Intumescent Coatings

Safety Assurance Security

Page 2: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

This Presentation Is Prepared And Reviewed By Prokem Technical Office.

Eng. Ashraf Daghashi

Technical Manager

Page 3: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

The function of an intumescent coating is to delay steel members from reaching various critical steel temperatures above 500ºC at which they collapse after a given period of time.

This enables people to evacuate buildings and creates a time window facilitating the Fire Bridge to enter the building to search for and assist any trapped persons and begin to fight the fire

Page 4: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

• Latin words “in” and “tumescere” = “to swell up” • First patent in 1984. • Late 1950s/early 1960s from USA – heavy

bodied epoxy mastic nature begins to compete with cementitious versions of fire protection

• First half of 1960s years thin film intumescent “fire resisting coatings”

Page 5: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

There are three types of fire: • Cellulosic: burning wood or paper. • Hydrocarbon pool: burning oil or gas. • Hydrocarbon jet: pressurized oil or gas release.

Page 6: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

• Thin film coatings (cellulosic) - High expansivity - dft 0.25 – 0.50 mm - tested as per standardized time-temperature

curve ISO 834 - between ½ hour and 2 hours fire resistance.

Page 7: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Delays the time that the temperature at which the steel loses its structural strength is reached.

Tem

pera

ture

Time

Page 8: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

• Thick film coatings (hydrocarbon) - Low degree of expansion - 4 – 30 mm dft - to protect steel against hydrocarbon fires/jet

fires - for petrochemical industry/refineries and sea-oil

rigs - up to 3 hours fire resistance

Page 9: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Three main stages in the evolution of building fires: 1. Ignition 2. Growth by flame spread 3. Steady state burning period when the fire is fully developed. • Flame retardant paints for combustible substrates such as wood or cables/plastics • Intumescent fire resisting coatings for structural steel elements

Page 10: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

•FIRE GUARD: intumescent coating swells up heated, thus creating an effective barrier layer. The softening of steel which occurs at 500ºC is thus delayed, and valuable time for the saving of human life is gained. • FIRE GUARD satisfies numerous international specification and is approved in more than 30 countries round the world.

Page 11: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

FIRE GUARD is a coating that forms an insulating foam on exposure to fire.

Page 12: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Thin film intumescent coating systems are officially tested/approved as complete systems for structural steel members comprising: - anti-corrosive primers - intumescent fire protection base coat - top coat (colored)

Page 13: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

• Pretreatment of steel substrate • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements - Wet film thickness gauges - electro-magnetic induction dry film thickness gauge

Page 14: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

P

A

Perimeter of steel exposed

Cross-sectional area of steel

The ratio of perimeter length to cross-sectional area is termed Hp/A. The greater the value of Hp/A the faster the rate of heating of the section and since the purpose of the intumescent is to delay the rate of heating of the steel, the coating thickness increases with higher Hp/A values. Hp/A = =

Page 15: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements
Page 16: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Specialty Chemicals

Page 17: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Specialty Chemicals

Page 18: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Specialty Chemicals

Page 19: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Specialty Chemicals

Page 20: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Specialty Chemicals

Page 21: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

DFTs range from approximately 300 µm for 30 min. protection of a massive beam (Hp/A = Low) To > 3000 µm for 120 min. protection of a fragile beam (Hp/A = High)

Page 22: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

The fire protection performance is not affected by natural ageing, provided that - System correctly applied - maintenance control scheme - any damages repaired - should last for the lifetime of the building……

Page 23: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

All load bearing structural steel has to be protected

The extent of protection is subject to national or local regulations.

Only certified systems may be used

Page 24: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Advantages of FIRE GUARD versus other passive fire protecting systems (PFP) - Provides fire and corrosion protection - Does not change the statics of a steel structure - Easy application - Easy to repair - Preserves the appearance of the steel structure

Page 25: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

FIRE GUARD– the solution for structural steel - Interior, exterior and shop application - Corrosion protection - Primer compatibility - Easy application - Fire protection for the lifetime of the building

Page 26: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Theoretical Coverage Rate Description Product Name

10.4 sq. mt/lit (0.14 kg./m2) (50 μ) d.f.t

Two Components steel Epoxy Anti-corrosive Primer

*PRIMERS KEMPRIME M

11.4 sq. mt/lit (0.16 kg./m2) (50 μ) d.f.t

Economic Two Components Zinc Rich Epoxy Primer

KEMPRIME ZRS

0.178 sq. mt/lit (0.17 kg./m2) (50 μ) d.f.t

Two-component water based epoxy primer

BONDING PRIMER

Page 27: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Theoretical Coverage Rate Description Product Name

-1.2 kgm/m2 at D.F.T 600 microns , For fire protection for 60 minutes based on BS 476 Part 21. -4.0 kgm/m2 at D.F.T 3000 microns , Forfire protection for 120 minutes based on BS 476 Part 21.

Fire Guard is a water based intumescent coating which forms a tough, flexible, chemical resistant membrane with outstanding fire retardant properties, suitable for internal surfaces and for external applications, it should be finished with a weather resistant top coat such as (DECACOAT W, PROTHANE TC). It achieves the highest fire ratings of international standards including BS 476 parts 4,5,6,7. Upon curing, it is completely waterproof and forms a highly effective defense against aggressive elements such as chlorides, and atmospheric pollution. It presents an effective vapor barrier and is suitable for steel structure ,buildings and concrete

*BASE COAT FIRE GUARD

Page 28: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Theoretical Coverage Rate Description Product Name

-1.2 kgm/m2 at D.F.T 600 microns , For fire protection for 60 minutes based on BS 476 Part 21. -4.0 kgm/m2 at D.F.T 3000 microns , Forfire protection for 120 minutes based on BS 476 Part 21.

Fire Guard is a water based intumescent coating which forms a tough, flexible, chemical resistant membrane with outstanding fire retardant properties, suitable for internal surfaces and for external applications, it should be finished with a weather resistant top coat such as (DECACOAT W, PROTHANE TC). It achieves the highest fire ratings of international standards including BS 476 parts 4,5,6,7. Upon curing, it is completelywaterproof and forms a highly effective defense against aggressive elements such as chlorides, and atmospheric pollution. It presents an effective vapor barrier and is suitable for steel structure,buildings and concrete

*TOP COAT FIRE GUARD

Page 29: Intumescent Coatings - prokemsc.com€¦ · • Primer - Primer compatibility test - History • Intumescent coat • topcoat = finish / sealer • Drying times / thickness measurements

Alexandria : 33 Safeya Zaghloul St., Down Town, Alexandria.

Tel.: (03) 48 03 320 Fax : (03) 48 03 303

Cairo : 3 El Andalos St., Behind Merryland, Misr El Gadida.

Tel. : (02) 45 49 294 Fax : (02) 45 40 343

Factory : Borg El-Arab El Gadida city, Zone 12, Block 1

E-mail : [email protected]

Web site: www.prokemsc.com

PROKEM Provides Durable And Reliable Protection