Scenario 1 Wide-scale assessment of heating energy needs
for residential buildings
Scenario 2 Building energy awareness tools to support
efficient management of heating/cooling systems
Scenario 3 Remote monitoring and control of public lighting systems
to support a more energy efficient management
Scenario 1 Wide-scale assessment of heating energy needs
for residential buildings
L’idea… • Stime dettagliate disponibili solo per un insieme ristretto di edifici/unità
immobiliari • Obiettivo è una stima semplificata, che possa essere applicata a
grande scala, basandosi sui dati di base e disponibili pubblicamente – Footprints, heights, construction periods…
– Building construction typologies…
L’obiettivo… • Fornire strumenti di monitoraggio, stima e pianificazione per gli
amministratori pubblici relativi al consumo energetico di edifici
residenziali su scala cittadina.
In tutta Europa i certificati
energetici riguardano una
piccola fetta dello stock edilizio.
In Italia, nel 2014, solo il 6% delle
unità immobiliari aveva un APE
3,6 milioni di APE/ACE emessi a dicembre 2014 (http://www.cti2000.eu/rapporto-ce-2014/)
59 milioni di unità immobiliari censite al 2011 (A, B, C, D, E) (http://wwwt.agenziaentrate.gov.it/mt/comunicazione/Gli%20immobili%20in%20Italia%202011/Gli%20immobili%20in%20Italia%202011%20-%20capitolo%201.pdf)
Rapporto 2014 - Attuazione della certificazione energetica degli edifici in Italia http://www.cti2000.eu/rapporto-ce-2014/
In Emilia-Romagna gli APE/ACE
a fine 2014 erano
595.389
- 84% residenziale
- 16% altri settori
Dati geografici in numeri
Db topografico regionale - circa 30 milioni di oggetti geografici
- quasi 1,8 milioni di edifici
- tutti gli oggetti gestiti con profondità storica
Db catastale - 15 milioni di unità immobiliari
- 5,5 milioni di proprietari (5 fisici, 0,5 legali)
- 46 milioni di relazioni proprietari-proprietà
Energy label (the Netherlands) …
http://energielabelatlas.nl/#zuid-holland/delft/17/52.0122/4.3612
https://www.youtube.com/watch?v=6kslOHSRY8U https://www.youtube.com/user/SunshineProjectEu/videos
http://sunshine.graphitech-projects.com
Heating energy need estimation
Set of software modules for:
1. Model/import open geodata on spatial db – GeoUML Catalogue, PostGIS, QGIS
2. Verify completeness/correctness (app) – PhoneGap
3. Compute energy needs – WPS
4. Visualize / simulate / validate – Cesium
Footprint, superfici, numero UIU, usi
databese topografico, db catastale, ACI
Consumo gas / elettricità
Servizio SIATEL (Ag.Entrate)
Età, altezza (osservazione e
misurazione sul campo)
EP, trasmittanza e altre proprietà da SACE
e/o stima da dati tipologici (TABULA)
DB Topografico Regionale
Anagrafe Comunale degli Immobili
ww
w.s
un
shin
ep
roje
ct.
eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
Databases and desk research Age of construction of buildings (source: Cervellati L. (editor), 1976, Il centro storico di Ferrara, Franco Angeli)
Buildings destroyed during II world war
(source: University of Ferrara)
Missing mandatory
data; not verified.
Alcuni
Missing mandatory
data; verified.
All mandatory data
present; not verified.
All mandatory data present; verified.
Building properties (on 2nd click)
Editing of multi-value attribute
ww
w.s
un
shin
ep
roje
ct.
eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
On-field data verification
Click to open YouTube video
ww
w.
su
ns
hi
ne
pr
oj
ec
t.
eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
Qt = 10-3 HT 24 DD V S/V A [kWh/mA
2year] = [kW/mS2K] [h/Kyear] [mS
2/mA2]
Building Type Construction Year
Facade element
Typical U-value [W/m2K]
Typical % of facade
Walls full/semi-full bricks 1,08
60%
Roof bricks and concrete 0,95
10%
Floor bricks and concrete 0,92
10%
Windows thermal break frames + low-emission glass
2,63
20%
Typical heath transmission coefficient for building envelope
HT [W/mS2K]
Country Climatic Zone
Typical climatic parameters
Heating season lenght 183 days
Average outdoor temperature during the heating season
12° C
Indoor design temperature 20° C
Typical Degree Days DDt [days/Kyear]
Typical building shape parameters
Heated volume (V) 1234 mS3
Shape factor (S/V) 0.66 mS-1
Useful floor area (A) 353 mS2
Typical Consumption Qt [kWh/mA
2year]
https://www.youtube.com/watch?v=6kslOHSRY8U https://www.youtube.com/user/SunshineProjectEu/videos
http://sunshine.graphitech-projects.com
Validation with consumption data (SIATEL)
Location Energy
Validation with energy certificates (SACE)
ww
w.
su
ns
hi
ne
pr
oj
ec
t.
eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
THANK YOU!
Luca Giovannini [email protected] Sinergis (SGIS)
Scenario 2
Building energy awareness tools to support
efficient management of heating/cooling systems
Efficient building energy management
Local metering infrastructure:
1. Smart digital meters or readers
2. Concentrator and publishing end-point
Set of software modules for:
1. Import consumption/weather data flows
2. Visualize/validate energy consumption
3. Correlate consumption with weather
4. Compute suggestions on efficient heating
system management based on weather
forecast
ww
w.s
un
shin
ep
roje
ct.
eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
Pilot’s Head-end
green button
SUNSHINE
Sensor DB
FTP local folder
local concentrator
green button
Data flow infrastructure
meters
weather stations
forecasts
Meteogrid
WFS
Scheduler
SOS
http://greenbuttondata.org/
Green Button is an industry-led standard to answer
to a White House request: provide customers with
easy access to their energy usage data in a
consumer-friendly and computer-friendly format.
http://greenbuttondata.org/
Example of GreenButton data
ww
w.s
un
shin
ep
roje
ct.
eu
SUNSHINE - Smart UrbaN ServIces for Higher eNergy Efficiency (GA no: 325161)
Smart meters / readers
https://sigym3.com/users/graphitech/maps/europe_obs/
Weather data repository - METEOGRID
Heating comfort profile – Scuole Elementari Poledrelli, Ferrara
Hourly consumption – Natural History Museum
Daily consumption – Natural History Museum
Hourly weather observations - Ferrara
Hourly weather forecast - Ferrara