INTRODUCTION - eco-nexion.com

28
INTRODUCTION Producer: Kaflon Marketing Department Date: May 2012

Transcript of INTRODUCTION - eco-nexion.com

Page 1: INTRODUCTION - eco-nexion.com

INTRODUCTION

Producer: Kaflon Marketing DepartmentDate: May 2012

Page 2: INTRODUCTION - eco-nexion.com

1. Company Development

2. Our Products

3. Our Partners

Page 3: INTRODUCTION - eco-nexion.com

1. Company Development

Page 4: INTRODUCTION - eco-nexion.com

Company Development

2002 Kaflon M&C Instruments Co. Ltd. was founded and Obtained Measuring Instruments Production License

2002-2004 Launched different kinds of flowmeter and obtained ISO9001:2000 Certificate

2005 Obtained First-Class Supplier of CNPC and SINOPEC License

2006 Obtained Imports and Exports License and develop international trade

2011 Zhejiang Kaflon M&C Equipment CO. Ltd was founded and new factory will go into operation at March 2013

Page 5: INTRODUCTION - eco-nexion.com

Company Certificate

Page 6: INTRODUCTION - eco-nexion.com

Our new factory

Page 7: INTRODUCTION - eco-nexion.com

0

5

10

15

20

25

30

35

2002 2003 2004 2005 2006 2007 2008 2009 2010 2011

Sale (million RMB)

Growing Trend

Page 8: INTRODUCTION - eco-nexion.com

Company Strategy

Our core value is Rigorous and Focus.

Our core competitiveness is Continuous Innovation and Fast Response.

We provide reliable solution based on Customers’ Needs.

We provide excellent quality, timely service in order to Increase Customers’ Value.

Focus on Providing

Best Flow M&C

Solution.

Two Strategic Business

Continuous

Create Value for

Our Customers

Provide Reliable Measurement and Control Solution for Global Customers

Page 9: INTRODUCTION - eco-nexion.com

2. Our Products

Page 10: INTRODUCTION - eco-nexion.com

Our Products

Electromagnetic Flowmeter

• Based on Faraday Law, Measure Low conductive liquids• No inline parts, Long life time, High accuracy

Magnetic Vortex Flowmeter

• Based on Faraday Law and Karman Vortex Law, Measure conductive liquids, battery supply• No moving parts, Low pressure lost

Turbine Flowmeter and Electronic Watermeter

• Economic solution• Battery supply, can measure nonconductive liquids

Automatic Flow Controller

• Automatic control the flow rate • Combine the flow measuring part and control valve together

Page 11: INTRODUCTION - eco-nexion.com

Electromagnetic Flowmeter

MAG1000 Standard Flanged Type

• Diameter: DN6mm-DN2200mm• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Electrodes: 316L, Titanium, Tantalum, HC, Monel, Pt-Ir• Lining: FEP (DN6-DN300mm), Rubber (DN65-2200mm)• Sensor Housing Material: Carbon Steel

Page 12: INTRODUCTION - eco-nexion.com

Electromagnetic Flowmeter

MAG2000 Wafer Type

• Diameter: DN25-DN200mm• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Electrodes: 316L, Titanium, Tantalum, HC, Monel, Pt-Ir• Lining: FEP• Sensor Housing Material: Carbon Steel, SS304

Page 13: INTRODUCTION - eco-nexion.com

Electromagnetic Flowmeter

MAG3000 Sanitary Type

• Diameter: DN25-DN100mm• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Electrodes: 316L, Titanium, Tantalum, HC, Monel, Pt-Ir• Lining: FEP• Connection: Tri-Clamp, Thread (DIN11851)• Sensor Housing Material: SS304

Page 14: INTRODUCTION - eco-nexion.com

Electromagnetic Flowmeter

MAG4000 Stainless Steel Type

• Diameter: DN10-DN200mm• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Electrodes: 316L, Titanium, Tantalum, HC, Monel, Pt-Ir• Lining: FEP• Sensor Housing Material: Polished SS304, Full Welding

Page 15: INTRODUCTION - eco-nexion.com

Electromagnetic Flowmeter

MAG4000 High Pressure Type

• Diameter: DN10-DN200mm• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Electrodes: 316L, Titanium, Tantalum, HC, Monel,• Lining: FEP• Working Pressure: PN16MPa, 25MPa, 32MPa, 42MPa• Sensor Housing Material: Carbon Steel

Page 16: INTRODUCTION - eco-nexion.com

Electromagnetic Flow Transmitter

MT100 Standard Type

• Matched Size: DN3-3000mm • Power Supply: 85-240VAC, 20-36VDC• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Exciting current: 187mA• Menu Language: Chinese, English• Flow Display: Forward and Reverse Flow rate, Total Flow, Velocity• Alarm Function: Empty Pipe Alarm, System Alarm• Signal Output: Pulse, Frequency, 4-20mA (4 or 2 wire)• Communication: MODBUS, HART, PROFIBUS

Page 17: INTRODUCTION - eco-nexion.com

Electromagnetic Flow Transmitter

MT110 Remote Type

• Matched Size: DN3-3000mm • Power Supply: 85-240VAC, 20-36VDC• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Exciting current: 187mA• Menu Language: Chinese, English• Flow Display: Forward and Reverse Flow rate, Total Flow, Velocity• Alarm Function: Empty Pipe Alarm, System Alarm• Signal Output: Pulse, Frequency, 4-20mA (4 or 2 wire)• Communication: MODBUS, HART, PROFIBUS

Page 18: INTRODUCTION - eco-nexion.com

Electromagnetic Flow Transmitter

MT120 Explosion Type

• Matched Size: DN3-3000mm • Power Supply: 85-240VAC, 20-36VDC• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Exciting current: 187mA• Menu Language: Chinese, English• Flow Display: Forward and Reverse Flow rate, Total Flow, Velocity• Alarm Function: Empty Pipe Alarm, System Alarm, Contact alarm• Signal Output: Pulse, Frequency, 4-20mA (4 or 2 wire)• Communication: MODBUS, HART, PROFIBUS

Page 19: INTRODUCTION - eco-nexion.com

Electromagnetic Flow Transmitter

MT130 Process Control Type

• Matched Size: DN10-500mm • Power Supply: 85-240VAC, 20-36VDC• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Exciting current: 187mA• Flow Display: No Display• Alarm Function: No Alarm• Signal Output: Pulse, 4-20mA• Communication: No Communication

Page 20: INTRODUCTION - eco-nexion.com

Electromagnetic Flow Transmitter

MT150 Battery Supply Type

• Matched Size: DN10-1000mm • Power Supply: Battery Supply• Accuracy: 0.5% of rate (Span: 0.5-10m/s),

0.5%FS (Span: 0-0.5m/s) • Battery Life time: 5 years• Flow Display: Flow rate, Velocity, Total Flow• Alarm Function: Empty Pipe Alarm, Battery Volume Alarm• Signal Output: Pulse only for calibrating• Communication: No Communication

Page 21: INTRODUCTION - eco-nexion.com

Magnetic Vortex Flowmeter

MSW1000 Standard FLanged Type

• Diameter: DN10-200mm • Electrodes: SS316L• Tube Material: SS304• Liquids: Conductive Liquids• Accuracy: 1.0% of rate (Span: 0.4-10m/s)• Power Supply: Battery Supply, 24VDC• Battery Life time: 3 years• Flow Display: Flow rate, Total Flow• Signal Output: Pulse, Frequency, 4-20mA, (24VDC Supply) • Communication: RS485 MODBUS (24VDC Supply)

Page 22: INTRODUCTION - eco-nexion.com

Magnetic Vortex Flowmeter

MSW2000 Standard Thread Type

• Diameter: DN10-50mm • Electrodes: SS316L• Tube Material: SS304• Liquids: Conductive Liquids• Accuracy: 1.0% of rate (Span: 0.4-10m/s)• Connection: Thread• Power Supply: Battery Supply, 24VDC• Battery Life time: 3 years• Flow Display: Flow rate, Total Flow• Signal Output: Pulse, Frequency, 4-20mA, (24VDC Supply) • Communication: RS485 MODBUS (24VDC Supply)

Page 23: INTRODUCTION - eco-nexion.com

Magnetic Vortex Flowmeter

MSW1110 High Pressure Type

• Diameter: DN25-80mm• Working Pressure: PN16MPa, 25MPa, 35MPa, 42MPa • Sensor Housing: Carbon Steel• Liquids: Conductive Liquids• Accuracy: 1.0% of rate (Span: 0.4-10m/s)• Connection: Flanged• Power Supply: Battery Supply, 24VDC• Battery Life time: 3 years• Flow Display: Flow rate, Total Flow• Signal Output: Pulse, Frequency, 4-20mA, (24VDC Supply) • Communication: RS485 MODBUS (24VDC Supply)

Page 24: INTRODUCTION - eco-nexion.com

Turbine Flowmeter

TB1000 Standard Type

• Diameter: DN4-200mm• Tube Material: SS304, SS316• Accuracy: 1.0% of rate, 0.5% of rate • Connection: Thread (DN4-40mm), Flange (DN40-200mm)• Power Supply: Battery Supply, 24VDC• Battery Life time: 3 years• Flow Display: Flow rate, Total Flow• Signal Output: Pulse, Frequency, 4-20mA, (24VDC Supply)

Page 25: INTRODUCTION - eco-nexion.com

Electronic Watermeter

WT1000 Standard Type

• Diameter: DN25-500mm• Tube Material: Casting Steel• Accuracy: 2.0% of rate • Connection: Flange• Power Supply: Battery Supply, 24VDC• Battery Life time: 3 years• Flow Display: Flow rate, Total Flow• Signal Output: Pulse, Frequency, 4-20mA, (24VDC Supply)

Page 26: INTRODUCTION - eco-nexion.com

Automatic Flow Controller

FAC1020 Standard Type

• Diameter: DN10-200mm• Accuracy: 1.0% of rate • Connection: Flange• Power Supply: Battery Supply, 24VDC, 220VAC• Battery Life time: 3 years• Flow Display: Flow rate, Total Flow• Signal Output: Pulse, Frequency, 4-20mA, (24VDC Supply)

Page 27: INTRODUCTION - eco-nexion.com

Application

……

Pharmacy FoodPlastic Package

Power PlantPrinting Textile Tobacco

EngineerTransportation Building

Page 28: INTRODUCTION - eco-nexion.com