2
IntroductionPhenomenex is proud to introduce Lux™, our new line of
polysaccharide-based chiral stationary phases.
We know chiral separations can be challenging. With many
different product offerings in the industry, it may be difficult to
find the appropriate column to fit your needs.
Lux™ columns are engineered to provide a straightforward
approach to enantiomeric recognition and separation through
HPLC and SFC.
Lux™ columns are offered with two chiral stationary phases
(CSPs), both of which use coated derivatized cellulose as the
chiral selector. With new phases continuously in development,
you can rest assured that Lux™ columns will meet your chiral
separation demands of today as well as provide the latest in
chiral separation technologies for years to come.
3
Overview of Lux™ Chiral Stationary PhasesFeatures
Lux™ Cellulose-2
Lux™ Cellulose-1
Broad chiral recognition
For screening of new chiral compounds
Cellulose backbone
Increased loading capacity
Scalable 3 μm and 5 μm media
Stable in NP, Polar Organic, SFC and RP conditions
Novel selectivity
Similar selectivity to *CHIRALCEL® OD-H®
Cost-effective replacement to *CHIRALCEL® OD-H®
Table of ContentsChoosing the Right Chiral Stationary Phase ..............3
Chiral Recognition in Cellulose Phases ......................4
Inside Lux™ Chiral Stationary Phases .........................5
Lux™ Cellulose-2 ........................................................6
Lux™ Cellulose-1 ......................................................12
Ordering Information ................................................18
Trademarks Lux, Axia, SecurityGuard and Phenex are trademarks of Phenomenex, Inc. *CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd.
Disclaimer Comparative separations may not be representative of all applications. Subject to Phenomenex Standard Terms & Conditions, which may be viewed at www.phenomenex.com/TermsAndConditions.
© 2008 Phenomenex, Inc. All rights reserved.
Phenomenex | Web: www.phenomenex.com
4
Cellulose Backbones
Over the past two decades, derivatized cellulose has
established itself as one of the most universal platforms
for separating racemic mixtures. It offers a variety of chiral
recognition mechanisms, including:
steric effects (attractive and repulsive)•
hydrogen bonding•
π - π interactions•
dipole interactions•
ionic interactions•
Broad Solvent System Compatibility
Derivatized cellulose is often compatible with a wide range of
solvent systems:
Normal Phase•
Polar Organic•
SFC (Supercritical Fluid Chromatography)•
Reversed Phase•
Chiral Recognition Mechanisms in Cellulose Phases
Phenomenex | Web: www.phenomenex.com
5
Enantioselective Polysaccharide Derivatives
Lux™ columns utilize polysaccharide derivatives that yield
broad-ranged enantiomeric selectivity.
Benefits include:
Unique halogenated substitution with • Lux™ Cellulose-2
Improved resolution with many separations using • Lux™ Cellulose-1 compared to *CHIRALCEL® OD-H®.
Specialized Coating Process
Lux™ media undergoes a specialized coating process onto
high quality silica. Significant benefits from this process
include:
High loading capacity•
Stable, reproducible phases•
Stability in a variety of solvents, including SFC conditions• †
Scalable Particle Sizes
Lux™ columns come in 3 μm and 5 μm particle sizes to
accommodate all your resolution and throughput needs.
pH Stability
Lux™ columns are pH stable from 2 – 8, providing options for
reversed phase chiral method development.
Complete Package Solution
No need to hassle with different columns or part numbers
if your chiral methods take you down different routes of
development. Lux™ columns are compatible with different
solvent strategies:
Normal Phase•
Polar Organic•
SFC (Supercritical Fluid Chromatography)•
Reversed Phase•
Inside Lux™ Chiral Stationary PhasesAlthough there may be various polysaccharide-based columns
on the market, it is important to note the following
about Lux™ chiral stationary phases:
†Consult the Lux column care and use notes for full details on solvent limitations, which can be found at www.phenomenex.com/info/luxnotes*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd.
Phenomenex | Web: www.phenomenex.com
6
O
O
C
H
N
O
HH
C
C
C
C
C
CC
H
H
H
H
Cl
O
O
O
N
C
O
H
N
Cl
H
H
HH
C
C
H
HC
H
H
H
O
H
Cl
Cellulose-2
O
O
C
H
N
O
HH
C
C
C
C
C
CC
H
H
H
H
Cl
O
O
O
N
C
O
H
N
Cl
H
H
HH
C
C
H
HC
H
H
H
O
H
Cl
Phenyl rings contribute to π- π interactions.
Chlorine atoms have strong electronegativity, contributing to dipole interactions.
Cellulose backbones form linear chains, creating various grooves and cavities which provide steric and inclusion interactions.
Lux™ Cellulose-2 uses the chiral selector cellulose tris(3-chloro-4-methylphenylcarbamate)
Electronegative atoms, such as oxygen, nitrogen, and chlorine are responsible for hydrogen bonding.
7
O
O
C
H
N
O
HH
C
C
C
C
C
CC
H
H
H
H
Cl
O
O
O
N
C
O
H
N
Cl
H
H
HH
C
C
H
HC
H
H
H
O
H
Cl
O
O
C
H
N
O
HH
C
C
C
C
C
CC
H
H
H
H
Cl
O
O
O
N
C
O
H
N
Cl
H
H
HH
C
C
H
HC
H
H
H
O
H
Cl
Lux™ Cellulose-2Advanced chiral selector provides a unique range of enantioselectivity
Lux™ Cellulose-2 incorporates an advanced halogenated
derivative, leading to unique enantioselectivity compared to
previously commercialized cellulose phases.
The chiral selector is a cellulose
tris(3-chloro-4-methylphenylcarbamate)
It has been established that the introduction of either electron-
donating or electron-withdrawing groups, such as chlorine,
tends to improve the optical resolution abilities of chiral
stationary phases (CSPs) with phenylcarbamate derivatives.
In addition, substitution at the meta or para position on the
phenyl moiety is considered more beneficial than at the ortho
position to establish higher chiral recognition.1
The unique derivatization of Lux™ Cellulose-2 makes it an
ideal CSP to add to all chiral screening protocols and provides
excellent complementary selectivity to Lux™ Cellulose-1 in
many applications.
Studies show that for a set of 14 racemates of varying
properties, the 3-chloro-4-methylphenylcarbamate derivative
of cellulose was one of two derivatives, separating all 14
compounds with reasonable selectivity, with some better than
dimethylphenylcarbamate derivatives of cellulose.1
1. Bezhan Chankvetadze, Eiji Yashima, Yoshio Okamoto, J. Chromatography, 670 (1994) 39-49
Phenomenex | Web: www.phenomenex.com
8
Lux™ Cellulose-2 offers novel selectivity, improving chances of chiral resolution during multiple-column screening processes.
Lux™ Cellulose-2 vs. *ChIRaLCeL® OD-h®
0 2
21
4 6 min
0
200
400
600
800
mAU
17367
0 2
21
4 6 min
0
200
400
600
800
mAU
17368
17309
0 2
2
1
4 6 8 10 min
0
200
mAU
0 2
21
4 6 8 10 min
17310
0
200
mAU
0 2
2
1
4 6 min
0
200
400
600
mAU
17322
0 2
2
1
4 6 min
0
200
400
600
mAU
17323
Bupivacaine
Tolperisone
Miconazole
NNH
OH3C
CH 3
H 3C
N
N
O
Cl
Cl
Cl
Cl
*CHIRALCEL® OD-H®
a = 1.12
Lux™ Cellulose-2a = 1.18
Lux™ Cellulose-2a = 1.69
Lux™ Cellulose-2a = 1.17
*CHIRALCEL® OD-H®
a = 1.07
*CHIRALCEL® OD-H®
a = 1.08
Ap
p ID
173
09A
pp
ID 1
7322
Ap
p ID
173
67A
pp
ID 1
7310
Ap
p ID
173
23A
pp
ID 1
7368
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Methanol / 0.1 % Diethylamine
in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
N
O
H 3CCH3
*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd. Comparative separations may not be representative of all applications.
Phenomenex | Web: www.phenomenex.com
9
17387
0 105 15
2
1
20 min
0
200
400
600
800
1000
1200
1400
mAU
17388
0
200
400
600
800
1000
1200
1400
mAU
0 5 1510
2
1
20 min
17330
0 2
2
1
4 6 min
0
200
400
mAU
0 2
21
4 6 8
0
200
400
mAU
17331
17349
0 2
2
1
4 6 8 min
0
200
400
mAU
17350
0 2
2
1
4 6 8 min
0
200
400
mAU
Tramadol
N-(3,5-Dinitrobenzoyl)-a’-methylbenzylamine
Mephenytoin
N
HN
O
CH3
H 3C
O
Lux™ Cellulose-2a = 1.32
Lux™ Cellulose-2a = 1.83
Lux™ Cellulose-2a = 1.23
*CHIRALCEL® OD-H®
a = 1.69
*CHIRALCEL® OD-H®
a = 1.19
*CHIRALCEL® OD-H®
a = 1.13A
pp
ID 1
7330
Ap
p ID
173
49A
pp
ID 1
7388
Ap
p ID
173
87A
pp
ID 1
7331
Ap
p ID
173
50
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (80:20)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (80:20)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (60:40)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Hexane / 0.1 % Diethylamine
in Isopropanol (60:40)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
NCH 3
H
OH
H 3C
H 3CO
Additional applications are available upon request.
O–O
–ON+
N+
O
HN
O
*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd. Comparative separations may not be representative of all applications.
Phenomenex | Web: www.phenomenex.com
10
0 2
21
4 6 min
0
200
400
600
800
1000
mAU
17396
0 2 4 6 min
12
0
200
mAU
17420
0 2 4 6 min
1 2
0
200
mAU
17421
0 2
2
1
4 6 8 min
0
2000
mAU
17461
0 2
21
4 6 8 min
0
2000
mAU
17462
Econazole
Terfenadine
Etozolin
Lux™ Cellulose-2a = 2.79
Lux™ Cellulose-2a = 1.28
*CHIRALCEL® OD-H®
a = 1.04
*CHIRALCEL® OD-H®
a = 1.39
*CHIRALCEL® OD-H®
a = 1.23
Ap
p ID
174
20A
pp
ID 1
7395
Ap
p ID
173
96A
pp
ID 1
7462
Ap
p ID
174
61A
pp
ID 1
7421
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
N
N
Cl
ClO
Cl
N
O H
O H
C(CH3)3
Lux™ Cellulose-2 vs. *ChIRaLCeL® OD-h® (continued)
N
SN O
O
CH 3
O CH 3
0 2
2
1
4 6 min
0
200
400
600
800
1000
mAU
17395
Lux™ Cellulose-2a = 1.23
*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd. Comparative separations may not be representative of all applications.
Phenomenex | Web: www.phenomenex.com
11
Additional applications are available upon request.
0 2
21
4 min
0
200
mAU
17455
0 2
21
4 min
0
200
mAU
17456
0 2
2
1
4 6 min
0
200
mAU
17458
0 2
21
4 6 min
0
200
mAU
17459
0 2
2
1
4 6 8 10 min
0
200
400
600
mAU
17464
0 2
21
4 6 8 10 min
0
200
400
600
mAU
17465
Bifonazole
Mirtazapine
Nomifensine
Lux™ Cellulose-2a = 1.44
Lux™ Cellulose-2a = 1.27
Lux™ Cellulose-2a = 1.27
*CHIRALCEL® OD-H®
a = 1.11
*CHIRALCEL® OD-H®
a = 1.24
*CHIRALCEL® OD-H®
a = 1.07
Ap
p ID
174
56A
pp
ID 1
7458
Ap
p ID
174
59A
pp
ID 1
7465
Ap
p ID
174
64A
pp
ID 1
7455
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-2Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4457-E0Mobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Acetonitrile /
0.1 % Diethylamine in Isopropanol (95:5)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
NN
N
CH3
NCH 3
NH 2
N
N
*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd. Comparative separations may not be representative of all applications.
Phenomenex | Web: www.phenomenex.com
12
H
HH
H
HC
C
H
HH
C
C
H
HH
H
O
O
C
H
N
O
HH
C
C
C
C
C
CC
H
H
H
H
O
O
O
N
C
O
H
N
HH
H
HH
C
C
H
O
H
H
HH
H
HC
C
H
HH
C
C
H
HH
H
O
O
C
H
N
O
HH
C
C
C
C
C
CC
H
H
H
H
O
O
O
N
C
O
H
N
HH
H
HH
C
C
H
O
H
Cellulose backbones form linear chains, creating various grooves and cavities which provide steric interactions.
Phenyl rings contribute to π- π interactions.
Electronegative atoms, such as oxygen and nitrogen, are responsible for hydrogen bonding.
Cellulose-1
Lux™ Cellulose-1 uses the chiral selector cellulose tris(3,5-dimethylphenylcarbamate)
13
H
HH
H
HC
C
H
HH
C
C
H
HH
H
O
O
C
H
N
O
HH
C
C
C
C
C
CC
H
H
H
H
O
O
O
N
C
O
H
N
HH
H
HH
C
C
H
O
H
H
HH
H
HC
C
H
HH
C
C
H
HH
H
O
O
C
H
N
O
HH
C
C
C
C
C
CC
H
H
H
H
O
O
O
N
C
O
H
N
HH
H
HH
C
C
H
O
H
Lux™ Cellulose-1The new choice for dimethylphenylcarbamate separations
Lux™ Cellulose-1 features a classical cellulose derivative used
industry-wide for many enantiomeric separations.
The derivative is cellulose
tris(3,5-dimethylphenylcarbamate)
This particular chiral selector has well established abilities
in resolving a wide range of racemates. Lux™ Cellulose-1
provides enhanced resolution for a variety of applications
compared to similar CSPs.
This derivative of cellulose has a well established history
of broad enantioselectivity. The substitution of the electron
donating methyl groups at the 3 and 5 position enhance
the activity of the phenyl group. This leads to enhanced
enantioselectivity for aromatic and conjugated compounds.
In addition, Lux™ Cellulose-1 undergoes a specialized
manufacturing and coating process, which, as shown in this
brochure, provides greater resolution for many applications
compared to *CHIRALCEL® OD-H® .
*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd.
Phenomenex | Web: www.phenomenex.com
14
17314
0 2
2
1
4 6 min
0
200
400
1000
800
600
mAU
17316
0 2
2
1
4 6 min
0
200
400
1000
800
600
mAU
Lux™ Cellulose-1 offers exceptional separations for your existing polysaccharide methods.
Naringenin
Orphenadrine
Lux™ Cellulose-1 vs. *ChIRaLCeL® OD-h®
*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd. Comparative separations may not be representative of all applications.
17327
2
2
1
4 6 min0
0
200
400
600
mAU
0 2
2
1
4 6 min
17328
0
200
400
600
mAU
Ap
p ID
173
14A
pp
ID 1
7316
Ap
p ID
173
27A
pp
ID 1
7328
Lux™ Cellulose-1a = 1.30
Lux™ Cellulose-1a = 1.89
*CHIRALCEL® OD-H®
a = 1.24
*CHIRALCEL® OD-H®
a = 1.94
OHO
O H O
O H
O
CH 3
NCH3
CH3
Column: Lux™ 5 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4459-E0Mobile Phase: 0.1 % Formic acid in Hexane /
0.1 % Formic acid in Isopropanol (60:40)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Formic acid in Hexane /
0.1 % Formic acid in Isopropanol (60:40)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4459-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Phenomenex | Web: www.phenomenex.com
15
0 2
2
1
4 6 8 min
17319
0
200
400
mAU
17320
0 2
2
1
4 6 8 min
0
200
400
mAU
0
200
400
600
mAU
0 2
2
1
4 6 8 10 12 min
17341
0
200
400
600
mAU
0 2
2
1
4 6 8 10 12 min
17342
Bisoprolol
Mebeverine
*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd. Comparative separations may not be representative of all applications.
Ap
p ID
173
19A
pp
ID 1
7342
Ap
p ID
173
41A
pp
ID 1
7320
Lux™ Cellulose-1a = 1.74
Lux™ Cellulose-1a = 1.29
*CHIRALCEL® OD-H®
a = 1.83
*CHIRALCEL® OD-H®
a = 1.24
H 3CO
H 3CO
O
ON
CH3
CH3
OCH3
O
OO CH3
CH3NH
H3C
O H
CH 3
Column: Lux™ 5 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4459-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (80:20)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (80:20)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4459-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (80:20)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (80:20)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Additional applications are available upon request.
Phenomenex | Web: www.phenomenex.com
16
Indapamide
Dimethindene
Homatropine
*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd. Comparative separations may not be representative of all applications.
0 2 4 6 min
0
200
400
600
mAU
17365
1
2
0 2
2
1
4 6 min
0
200
400
600
mAU
17366
0 2 4 6 min
0
200
400
mAU
17376
1
2
0 2 4 6 min
0
200
400
mAU
1
2
17377
0 1 2 3 4 5 min
1
2
0
200
400
600
800
mAU
17378
0 1 2 3 4 5 min
1
2
0
200
400
600
800
mAU
17379
Lux™ Cellulose-1a = 1.82
Lux™ Cellulose-1a = 2.47
Lux™ Cellulose-1a = 2.06
*CHIRALCEL® OD-H®
a = 1.67
*CHIRALCEL® OD-H®
a = 2.07
*CHIRALCEL® OD-H®
a = 1.20
Ap
p ID
173
65A
pp
ID 1
7366
Ap
p ID
173
78A
pp
ID 1
7379
Ap
p ID
173
77A
pp
ID 1
7376
N
HN
CH 3
O
SNH 2
Cl
O O
N
O
O
O H
CH 3
H 3C
NCH 3
CH3
N
Column: Lux™ 5 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4459-E0Mobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Methanol / 0.1 %
Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4459-E0Mobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4459-E0Mobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Lux™ Cellulose-1 vs. *ChIRaLCeL® OD-h® (continued)
Phenomenex | Web: www.phenomenex.com
17
Toliprolol
Mephenesine
Increase efficiencies by scaling down to 3 µm
Increase efficiencies of difficult separations of by scaling down
from 5 µm to 3 µm particles, available on both Lux™ Cellulose-1
and Lux™ Cellulose-2. 3 µm
*CHIRALCEL and OD-H are registered trademarks of DAICEL Chemical Industries, Ltd. Comparative separations may not be representative of all applications.
0 1 2 3 4 min
0
200
400
mAU
17372
2
11
0 1 2 3 4 min
0
200
400
mAU
1
2
17373
min0 2 4 6 8 10 12 14
min0 2
21
21
4 6 8 10 12 14
mAU
0
100
200
300
400
mAU
0
100
200
300
400 Lux™ Cellulose-15 µma = 1.16
Lux™ Cellulose-13 µma = 1.17
Lux™ Cellulose-1a = 1.67
*CHIRALCEL® OD-H®
a = 1.50A
pp
ID 1
7470
Ap
p ID
174
69A
pp
ID 1
7373
Ap
p ID
173
72
OHN CH3
O H
CH3
H 3C
Column: Lux™ 5 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4459-E0Mobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: *CHIRALCEL® 5 µm OD-H®
Dimensions: 250 x 4.6 mm IDMobile Phase: 0.1 % Diethylamine in Methanol /
0.1 % Diethylamine in Isopropanol (90:10)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 5 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4459-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (80:20)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
Column: Lux™ 3 µm Cellulose-1Dimensions: 250 x 4.6 mm ID
Part No.: 00G-4458-E0Mobile Phase: 0.1 % Diethylamine in Hexane /
0.1 % Diethylamine in Isopropanol (80:20)Flow Rate: 1 mL/minDetection: UV @ 220 nm
Temperature: Ambient
CH 3
O OH
OH
Additional applications are available upon request.
Phenomenex | Web: www.phenomenex.com
If you are not completely satisfied with Lux™ analytical columns, send in your comparative data within 45 days and KEEP THE COLUMN FOR FREE.
Lux™ Ordering Information
Extending Lifetime
Phenomenex recommends the use of SecurityGuard™ guard
cartridges to extend the lifetime of your column, especially with
samples extracted from complex matrixes. Ideally, samples must
be completely dissolved in the mobile phase or filtered through a
syringe filter of approximately 0.45 µm porosity.
18
Our promise of excellence doesn’t end with the delivery of our products.
Phenomenex pledges to provide on-going technical support and
customer service that matches the quality of our products. With offices
and a network of distributors worldwide, your needs will be taken care of
no matter where or when you call upon us.
Whether it’s for ordering, technical consulting, troubleshooting, or any
other array of needs, our team is knowledgeable and ready to assist you
each step of the way.
Go ahead and make the call – we’re waiting!
Phenomenex | Web: www.phenomenex.com
3 μm Analytical Columns (mm) SecurityGuard™ Cartridges (mm)150 x 2.0 100 x 4.6 150 x 4.6 250 x 4.6 4 x 2.0* 4 x 3.0*
Phases / 8pk / 8pk
Cellulose-1 00F-4458-B0 00D-4458-E0 00F-4458-E0 00G-4458-E0 AJ0-8402 AJ0-8403
Cellulose-2 00F-4456-B0 00D-4456-E0 00F-4456-E0 00G-4456-E0 AJ0-8398 AJ0-8366
for ID: 2.0–3.0 mm 3.2–8.0 mm
5 μm Analytical Columns (mm)SecurityGuard™ Cartridges (mm)
100 x 4.6 150 x 4.6 250 x 4.6 4 x 3.0
Phases / 8pk
Cellulose-1 00D-4459-E0 00F-4459-E0 00G-4459-E0 AJ0-8403
Cellulose-2 00D-4457-E0 00F-4457-E0 00G-4457-E0 AJ0-8366
for ID: 3.2–8.0 mm
5 μm Axia™ Packed Preparative Columns (mm) SecurityGuard™ Cartridges (mm)150 x 21.2 250 x 21.2 250 x 30 250 x 50 15 x 21.2** 15 x 30.0+
Phases / ea / ea
Cellulose-1 00F-4459-P0-AX 00G-4459-P0-AX 00G-4459-U0-AX 00G-4459-V0-AX AJ0-8405 AJ0-8406
Cellulose-2 00F-4457-P0-AX 00G-4457-P0-AX 00G-4457-U0-AX 00G-4457-V0-AX AJ0-8400 AJ0-8401
for ID: 18–29 mm 30–49 mm*SecurityGuard Analytical Cartridges require holder, Part No. : KJ0-4282**PREP SecurityGuard Cartridges require holder, Part No. : AJ0-8223+PREP SecurityGuard Cartridges require holder, Part No. : AJ0-8277
Column Performance Check StandardPart No. Description Unit Price
AL0-8412 Chiral Test Mix No. 5 (Lux) ea
Tip: Try a Sample Pack!
The best way to determine if a specific Phenex membrane is suitable for your application.
Request yours today by phone or visit www.phenomenex.com/sample
If Phenex™ Syringe Filters do not perform as well or better than your current syringe filter product of similar membrane, diameter and pore size, send in your comparative data within 45 days and keep the Phenex products for FREE!
Phenex™ Syringe FiltersFor Sample and Solvent Filtration Prior to Chromatography!
Less system down time•
Consistent, reproducible results•
Increased column lifetime•
Phenex Offers:
Low absorption »
Maximum chemical »compatibility
Minimum extractables »
Excellent flow rate »
High total throughput »
Low hold-up volume »
Certified quality »
100 % integrity tested »
Easy pore identification »
Bi-directional use »
Above syringe filters are non-sterile. Housing is made of medical-grade polypropylene (PP).
1. 17 mm diameter.2. Glass fiber filters are 28 mm diameter and made of borosilicate. They will remove 90 % of all particles >1.2 µm. 3. Housing material is methacrylate butadiene styrene (MBS) polymerisate. Also known as Cryolite™.4. Cellulose acetate is surfactant-free.5. 26 mm diameter.6. Hydrophobic membrane. Can be made hydrophilic by pre-wetting with IPA.7. 28 mm diameter.8. Additional dimensions and membrane types are available. Please contact your local Phenomenex technical consultant or distributor
for availability or assistance.9. Larger quantity purchases at significant savings are available.
Cryolite is a trademark of CY/RO Industries. Phenex is a trademark of Phenomenex, Inc.
4 mm Diameterfor ≤ 2 mL sample volumes
15-17 mm Diameterfor 2 – 10 mL sample volumes
25-28 mm Diameterfor 10 – 100 mL sample volumes
Membrane Type/Size Part No. Unit Price Part No. Unit Price Part No. Unit Price
0.45 µm
Phenex-RC(Regenerated Cellulose)
AF0-3103-12 100/Pk AF0-2103-12 100/Pk AF0-8103-12 5 100/Pk
AF0-3103-52 500/Pk AF0-2103-52 500/Pk AF0-8103-52 5 500/Pk
Phenex-PES 3
(Polyethersulfone)
— — — AF2-5108-12 100/Pk AF0-8108-12 7 100/Pk
— — — — — — AF0-8108-52 7 500/Pk
Phenex-PTFE 6
(Polytetrafluoroethylene)
AF0-3102-12 100/Pk AF0-2102-12 100/Pk AF0-1102-12 100/Pk
AF0-3102-52 500/Pk AF0-2102-52 500/Pk AF0-1102-52 500/Pk
Phenex-NY(Nylon)
AF3-3107-12 100/Pk AF2-5107-12 100/Pk AF0-1107-12 100/Pk
AF3-3107-52 500/Pk AF2-5107-52 500/Pk AF0-1107-52 500/Pk
Phenex-GF/CA 2,3,4
Glass Fiber/Cellulose Acetate
An integrated syringe filter unit containing an inert borosilicate glass fiber prefilter and a CA membrane. Excellent for filtration of tissue culture media, general biological sample filtration and clarification.
AF0-8B09-12 7 100/Pk
AF0-8B09-52 7 500/Pk
0.20 µm
Phenex-RC(Regenerated Cellulose)
AF0-3203-12 100/Pk AF0-2203-12 100/Pk AF0-8203-12 5 100/Pk
AF0-3203-52 500/Pk AF0-2203-52 500/Pk AF0-8203-52 5 500/Pk
Phenex-PES 3
(Polyethersulfone)— — — — — — AF0-8208-12 7 100/Pk
— — — — — — AF0-8208-52 7 500/Pk
Phenex-PTFE 6
(Polytetrafluoroethylene)
AF0-3202-12 100/Pk AF0-2202-12 100/Pk AF0-1202-12 100/Pk
AF0-3202-52 500/Pk AF0-2202-52 500/Pk AF0-1202-52 500/Pk
Phenex-NY(Nylon)
AF3-3207-12 100/Pk AF2-5207-12 100/Pk AF0-1207-12 100/Pk
AF3-3207-52 500/Pk AF2-5207-52 500/Pk AF0-1207-52 500/Pk
Phenex-GF/CA 2,3,4
(Glass Fiber/Cellulose Acetate)
An integrated syringe filter unit containing an inert borosilicate glass fiber prefilter and a CA membrane. Excellent for filtration of tissue culture media, general biological sample filtration and clarification.
AF0-8A09-12 7 100/Pk
AF0-8A09-52 7 500/Pk1.20 µm
Phenex-GF 2,3
(Glass Fiber)An integrated syringe filter unit containing an inert borosilicate glass fiber prefilter and a CA membrane. Excellent for filtration of tissue culture media, general biological sample filtration and clarification.
AF0-8505-12 7 100/Pk
AF0-8505-52 7 500/Pk
LuxembourgMaarssenbroeksedijk 13D3542 DL UtrechtNetherlands
+31 (0)30-2418700+31 (0)[email protected]
NetherlandsMaarssenbroeksedijk 13D3542 DL UtrechtNetherlands
mail:
tel.:fax:
email:
mail:
tel.:fax:
email:
BelgiumMaarssenbroeksedijk 13D3542 DL UtrechtNetherlands
+31 (0)30-2418700+31 (0)[email protected]
Canada411 Madrid Ave.Torrance, CA90501-1430USA
(800) 543-3681(310) [email protected]
DenmarkGydevang 39-413450 AllerødDenmark
4824 80484810 [email protected]
AustraliaPO Box 4084Lane Cove, NSW 2066Australia
AustriaZeppelinstr. 563741 AschaffenburgGermany
FranceParc des Grillons, Bat.360 route de Sartrouville78232 Le Pecq CedexFrance
01 30 09 21 1001 30 09 21 [email protected]
GermanyZeppelinstr. 563741 AschaffenburgGermany
IrelandQueens Avenue,Hurds�eld Ind. Est.,Maccles�eld, Cheshire SK10 2BN, UK
01 247 5405+44 [email protected]
mail:
tel.:fax:
email:
ItalyVia M. Serenari, 15/D40013 Castel Maggiore (BO)Italy
051 6327511051 [email protected]
New ZealandP O Box 31-601Milford 0741North Shore CityNew Zealand
Puerto Rico273 Sierra Morena,Suite #104San Juan,Puerto Rico 00926
(800) 541-HPLC(310) [email protected]
United KingdomQueens Avenue,Hurds�eld Ind. Est.,Maccles�eld, Cheshire SK10 2BN, UK
USA411 Madrid Ave.Torrance, CA90501-1430USA
(310) 212-0555(310) [email protected]
www.phenomenex.comPhenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department by telephone, fax or email: [email protected].
5441
_I