Вер. 1 от 23.07.2011 Modcon was founded in 1972 and has an excellent reputation as an innovative supplier of turnkey on-line analysis, process automation and modern control systems for oil refineries, natural gas, chemical and Modcon Systems is a key player and recognized leader in: Oil refineries on-line analyzers and process Pipeline SCADA, metering stations, qualitative and quantitative control solutions Environmental control of air pollutions, contaminated soil and waste water Process analyzer shelters and complete Turn-key pipeline, compressor stations and processing plants EPC projects Petroleum on-line analyzers (NMR, NIR, ASTM, etc.) Analyzer Houses for oil refineries and petrochemical industry SCADA and MCS solutions for natural gas pipelines Natural gas analyzer systems and metering stations Continuous emissions monitoring systems SYSTEMS LTD LEADERS IN PROCESS ANALYSIS AND CONTROL Intrinsically Safe Gas Detector Model «FDG3» Bayblend OR Aluminium Enclosure Availible

Transcript of Intrinsically Safe Gas Detector - Indusmation · Intrinsically Safe Gas Detector ... Modcon Systems...

Вер. 1 от 23.07.2011

Modcon was founded in 1972 and has an excellent reputation as an innovative supplier of turnkey on-line analysis, process automation and modern control systems for oil refineries, natural gas, chemical and energy industries worldwide.

Modcon Systems is a key player and recognized leader in: Oil refineries on-line analyzers and process optimization Pipeline SCADA, metering stations, qualitative and quantitative control solutions Environmental control of air pollutions, contaminated soil and waste water Process analyzer shelters and complete analytical laboratories Turn-key pipeline, compressor stations and processing plants EPC projects

Main Products and Services: Petroleum on-line analyzers (NMR, NIR, ASTM,

etc.) Analyzer Houses for oil refineries and petrochemical

industry SCADA and MCS solutions for natural gas pipelines Natural gas analyzer systems and metering stations Continuous emissions monitoring systems

SYSTEMS LTD

LEADERS IN PROCESS ANALYSIS AND CONTROL

Intrinsically Safe Gas Detector

Model «FDG3»

Bayblend OR Aluminium Enclosure Availible

Modcon Systems specializes in performing process control automation, instrumentation and analyzer projects with turn-key delivery, support and training, since 1972. Modcon Systems is a key player in: On-line Process Analyzers and Systems Process Control & Automation SCADA and Industrial Network Solutions Environmental Control Gas Detectors and Air Pollution Analyzers

Modcon Systems - Model FGD3 is a Certified Intrinsically Safe Gas Transmitter / Display for use in industrial gas moni-toring applications. It can be configured to detect a variety of flammable and toxic gases as well as CO2 and Oxygen.

An LCD display and pushbutton operation make the Model FGD3 easy to operate and configure. The unit comes ready

for direct integration with plant PLC or DCS. A plug-in sensor design makes maintenance fast and easy. The FGD is

housed in a rugged, waterproof, and dustproof enclosure that features a tamper-proof cover.

Intrinsically Safe Gas Detectors – F o r t h e D e t e c t i o n o f O x y g e n o r T o x i c G a s e s

M O D E L « F G D 3 »

Features: LCD readout 4 to 20 milliamp output Pushbutton calibration Green flashing 'confidence' LED Integral sensor for cost sensitive applications Intrinsically safe Water and dust proof to IP66 RFI protected Marine version available (cast aluminium enclosure to provide higher RFI immunity where high power portable ra-

dios are used in the close confines of a vessel) Plug-in replaceable sensors

Hazardous Area Certificate Number

BAS 01ATEX2300 II 2 G EEx ia IIC T4 (-20⁰C<Ta<+60⁰C)

Zones 1 & 2

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

4 Modcon Systems International [email protected]

www.modcon.ru

W h a t I s A n I n t r i n s i c a l l y S a f e G a s D e t e c t o r ?

An Intrinsically Safe Gas Detector is one which is intended for use in a potentially explosive atmos-phere where, due to the nature of the environment or the industrial process taking place, there is the risk of an in-cendive spark from electrical apparatus causing an explosion.

These gas detectors are designed so that the energy produced in the event of an electrical fault is insufficient to cause an incendive spark.

An Electrical Safety Barrier Device must be used to connect power and signals between the gas detector and the 'Safe Area' (i.e. the area outside the potentially explosive atmosphere where mains powered equipment exists). This is nec-essary in order to preserve the safety integrity of the installation by limiting the power entering the potentially explo-sive atmosphere to a safe level - refer to the Accessories section for details of suitable barriers.

Examples are the water, pharmaceuticals and chemicals industries.

Modcon Systems offer the following ranges of intrinsically safe gas detectors:-

T y p e F G D 3 S e r i e s

The FGD3 series gas detectors are powered from an intrinsically safe dc power supply and provide an industry stand-ard 4 to 20mA output signal.

They are available for detection of the following common gas types - follow the links below for further information:-

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

5 Modcon Systems International [email protected]

www.modcon-systems.com

Nitrogen Dioxide Detector

Ammonia Detector

Sulphur Dioxide Detector

Nitric Oxide Detector

Hydrogen Detector

Hydrogen Chloride Detector

Hydrogen Cyanide Detector

Flammable Infrared Gas Detector

Carbon Dioxide Infrared Detector

Flammable Gas Detector (including Hydrogen) using 'Pellistor' sensor technology.

Oxygen Deficiency Detector

Hydrogen Sulphide Detector

Carbon Monoxide Detector

Chlorine Detector

Description

The FGD 3 Oxygen or Toxic gas detectors use Pellistor, electrochemical or non-dispersive Infrared (NDIR) sensor technology to detect for gases in the atmosphere in potentially explosive atmospheres in Zones 0, 1 and 2. The detec-tors use the industry standard 4-20mA current loop both to power the detector and to convey the gas levels detected to a control unit. This means that under zero gas conditions 4mA is drawn from the supply, and under full scale gas conditions 20mA is drawn from the supply. The current varies linearly for gas levels between zero and full scale. The detector head uses a two-wire connection.

FGD3 model Bayblend® enclosure is the trade name for product line of amorphous, thermoplastic polymer blends

based on polycarbonate (PC) and acrylonitrile butadiene styrene copolymer (ABS) as well as the rubber-modified

polycarbonate (PC) and styrene-acrylonitrile copolymer (SAN) blends. The blend technology employed supplies

products with an attractive combination of mechanical, thermal and rheological properties. Particular mention

should be made of Bayblend®`s high heat resistance (between that of ABS and PC), its high impact and notched im-

pact strength, and its high stiffness and dimensional stability.

The Bayblend® product range comprises:

- Nonreinforced standard grades (T grades)

- Nonreinforced flame-retardant grades (FR grades)

- Mineral-filled grades

- Glass fiber-reinforced T grades

- Special-purpose grades for specific applications

A marine version of the FGD3 is also available. This version is housed in a cast aluminium enclosure to provide higher RFI immunity where high power portable radios are used in the close confines of a vessel. The enclosure is plated and painted in order to withstand the harsh salt spray environment of the marine industry. The digital display is fitted with a sliding stainless steel front cover which remains over the display window when not being viewed thereby maintaining the RFI shielding properties of the enclosure during normal operation. An optional weather guard is available for installations exposed to the atmosphere or contaminants and is also suitable for use in other areas where hosing down takes place. The weather guard reduces the possibility of water or other contaminants entering into the gas sensor thereby improving the overall reliability of the gas detector in harsh environments. The weather guard is attached with tamperproof screws to ensure that it is not inadvertently removed.

Optional Weatherguard (may not be suitable for use with absorbent gases)

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

6 Modcon Systems International [email protected]

www.modcon.ru

Technical Characteristic

Performance

Measurement range

Dependent upon sensor type

Response time

Sensor response times vary according to the sensor type.

Sensor Type Pellistor, electrochemical, non-dispersive Infrared (NDIR)

Sensor MTBF 5 years for NDIR Infrared, temperature compensated, dual element

Gas Types Oxygen \ Toxic

Electrical Specifications

Supply volt-age

7 to 30 volts dc (for 4 to 20 mA signal)

Output Signal

4-20 мА (2-wire connection, current source ) 0mA - open circuit

2mA - fault

4mA - zero gas

20mA - full scale gas

22mA - over-range

Cable loop resistance

Signal - 480 Ohms at nominal 20v Sensor - 41 Ohms at 8.0V DC

Max. Cable Loop

Resistance

Signal - 560 ohms at 24vdc

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

7 Modcon Systems International [email protected]

www.modcon-systems.com

Mechanical Specifications

Enclosure Material Bayblend (ABS and Polycarbonate blending)

Optional marine version : This version is housed in a cast Aluminium enclo-sure .

Cable entry 1 x M20 or ½” NPT

Dimensions 122 x 122 x 75 mm

Weights FGD3 (excluding weatherguard) – 660grams

Weatherguard – 225 grams

Hazardous Area Certification

Certificate Number BAS 01ATEX2300, Code II 2G EEx ia IIC

Standards

EN 50014:1997 + Amds 1 & 2

EN 50018:2000

EN 50020:1994

Temperature Code T4 (-20OC<Ta<+60OC)

Zones 1 & 2

Operating Conditions

Operating Temperature - 20 to +40 deg.C

Storage temperature - 20 to +50 ⁰C

Humidity Range Oxygen - 0 to 99% RH non-condensing

Toxic - 15 to 95% RH non-condensing

Operating Pressure Ambient + or - 10%

IP rating Enclosure IP66, Sensor IP65

8 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

Gas Formula Stock Number

Maximum Range

Typical Range Setting

Expected Life (in Air)

Resolution Response Time

Oxygen O2 SS401 0 - 25% vol. * 0 - 21% vol. * 2 years 0.05% vol. T95<15 sec

Hydrogen sulfide H2S SS402 0 – 100ppm 0 - 50ppm 2 years 1ppm T90<30 sec

Carbon monoxide CO SS403 0 – 500ppm 0 - 500ppm 2 years 1ppm T90<25 sec

Chlorine CL2 SS404 0 – 50ppm 0 - 20ppm 2 years 0.1ppm T90<30 sec

Nitrogen dioxide NO2 SS405 0 – 20ppm 0 - 20ppm 2 years 0.1ppm T90<25 sec

Ammonia NH3 SS406 0 – 1000ppm 0 - 100ppm 1-2 years 1ppm T90<60 sec

Ozone O3 SS407 0 – 2ppm 0 - 2ppm 2 years 20ppb T90<150 sec

Volatile organic compounds

V.O.C. SS408 0-1000 ppm Detects a range of volatile organic compounds

Sulfur dioxide SO2 SS409 0 – 20ppm 0 - 20ppm 2 years 0.1ppm T90<35 sec

Nitric oxide NO SS410 0 – 250ppm 0 –100ppm 2 years 1ppm T90<20 sec

Hydrogen H2 SS411 0 – 100% LEL

0 – 100% LEL 2 years 1% LEL < 180 sec

Phosphine PH3 0 – 1ppm 0 – 0.5ppm 18 months 1ppb ** T90<30 sec

Hydrogen cyanide HCN 0 – 50ppm 0 – 25ppm 2 years 0.1ppm T90<200 sec

Hydrogen chloride HCL 0 – 50ppm 0 - 20ppm 1 year 0.1ppm T90<120 sec

Typical Sensor Characteris cs

* The oxygen instrument is not designed for hazardous area use in oxygen-enriched atmospheres. Hazardous area applications must be in the range is 0-21%. ** The resolution of the sensor itself is 15ppb.

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

9 Modcon Systems International [email protected]

www.modcon-systems.com

Typical MCU Control Unit Oxygen and Toxic Alarm Level Se ngs (Adjustable)

Gas Formula Level 1 Level 2 Level 3 Max. Adjustable FSD

Oxygen O2 19% vol. 23% vol. 25% vol. 25% vol.

Carbon monoxide CO 50ppm 110ppm 200ppm 500ppm

Chlorine CL2 1ppm 1.5ppm 2ppm 20ppm

Nitrogen dioxide NO2 10ppm 15ppm 20ppm 20ppm

Sulfur dioxide SO2 3ppm 5ppm 8ppm 20ppm

Hydrogen chloride HCL 1ppm 1.5ppm 2ppm 20ppm

Ozone O3 1ppm 1.5ppm 2ppm 2ppm

Hydrogen sulfide H2S 10ppm 15ppm 20ppm 50ppm

Ammonia NH3 25ppm 35ppm 50ppm 30ppm

Hydrogen cyanide HCN 5ppm 10ppm 15ppm 25ppm

Hydrogen H2 20% LEL

40% LEL 60% LEL 0-100% LEL

Nitric oxide NO 25ppm 35ppm 50ppm 100ppm

Phosphine PH3 150ppb 200ppb 250ppb 500ppb

I n t r i n s i c a l l y S a f e O u t p u t M o d u l e T y p e « S S 3 5 9 »

* The Intrinsically Safe Output Module shown above provides the necessary interface between a non-intrinsically safe, mains powered system and an FGD3 Infrared Gas Detector. Note that an intrinsically safe earth must be connected to the module to ensure safety.

Inputs 14-28vDC 12-24V

Current Loop Sensor Supply

Temperature -20 - +40°C

Humidity range 0-95% RH non-condensing

Operating pres-sure

Ambient + or – 10%

Internal Re-sistance

Current Loop : 270R ±5%

Source Re-sistance

Sensor Supply : 12.0R ±5%

Intrinsically Safe Outputs

Terminals 1 & 2 3 & 4

Uo 28V 7.5V

Certificate No. Baseefa 03ATEX0590X

Code II (1) G [EEx ia] IIC

Io .112A .66A

Po .8W 1.24W

Zones 1 or 2

Accessories

10 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

T E C H N I C A L D A T A S H E E T - S O U N D E R A L A R M « S S 3 6 7 »

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

Accessories

11 Modcon Systems International [email protected]

www.modcon-systems.com

Features: 9 SELECTABLE TONES HIGH IMPACT ABS CASE WIDE SUPPLY AND OPERATING TEMPERATURE BRIGHT RED FINISH OPTIONAL LOOP IN / LOOP OUT

ELECTRICAL SPECIFICATION

Operating Voltage 12V/24V

Supply Current 8mA

Audibility 105dB at 1m

Distance 108m

Frequency 700/950Hz

Operating Temp. Range -40°C to +55°C

Mechanical Specification

Overall Height 85mm

Overall Diameter 104mm

Fixing Holes 4mm Holes max

Fixing Diameters 50mm or 60mm

Gland Entry 2 x 20mm knockouts

T E C H N I C A L D A T A S H E E T - V I S U A L A L A R M ( C O L O U R R E D , A M B E R o r G R E E N ) « S S 3 6 9 »

Accessories

Features: EYE CATCHING FLASH RATE, 60FPM IMPACT RESISTANT POLYCARBONATE RANGE WIDE SUPPLY AND OPERATING TEMPERATURE THREE COLOURS AVAILABLE

ELECTRICAL SPECIFICATION

Operating Voltage 20-30Vdc Supply Current 90mA average Power Rating 2.1W Flash Energy Rating 1.0J

Operating Temperature Range -20°C to +55°C

Mechanical Specification

Overall Height 100mm Base Height 48mm Overall Diameter 93mm Fixing Holes 5mm Holes max Fixing Diameters 50mm or 60mm Gland Entry 2 x 20mm knockouts

12 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

T E C H N I C A L D A T A S H E E T - V I S U A L / A U D I B L E S T A T U S I N D I C A T I O N P A N -E L « S S 3 6 6 »

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

Accessories

13 Modcon Systems International [email protected]

www.modcon-systems.com

Electrical Specification

Operating Voltage 24V D.C.

Supply Current: Red / Yellow Xenon’s

105mA MAX.

Green LED Lamp 40mA MAX.

Sounder 25mA MAX.

Sounder Output level @1m 79-107dB(A)

(Depending on tone) ± 3dB.

Mechanical Specification

Overall dimensions: 480mm Long x 102mm Wide x 130mm Deep.

Weight: Approximately 3.5Kg.

Cable entries 2 off M20 Compression glands. Cable size: 8mm Di-ameter maximum.

Configuration Common negative supply, inde-pendent positive supply to each lamp and the sounder.

Mentor SCM ~ S i n g l e c h a n n e l c o n t r o l u n i t

Features include: Alphanumeric display with back light Built in audible visual alarms Micro-controller based Fully configurable Choice of remote and directly mounted gas detector heads One-man calibration for remote mounted gas detector heads Lockable steel enclosure; water and dust proof to IP66 Password protected Battery back-up 3 alarm outputs

The MCU1 is a single channel, wall mounting, monitoring and control unit for use in a safe area where there is no risk of the presence of potentially explosive gases. It can be used in either of the following ways:-

1. Fitted with an integral CO2 (Infrared), oxygen, or toxic sensor for safe area use only.

2. Connected to a remote CO2 (Infrared), oxygen, or a toxic gas detector head for safe area use only.

3. Fitted with an internal (or external) safety barrier and connected to a remote certified intrinsically safe (Ex ia) flammable, oxygen or toxic gas detector head sited in a hazardous area. (The range of heads includes flammable and CO2 (Infrared) types).

4. Connected to a remote flameproof (Ex d) certified flammable, oxygen or toxic gas detector head sited in a hazardous area.

14 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

15 Modcon Systems International [email protected]

www.modcon-systems.com

Integral S e n s i n g H e a d

Accepts any industrial transducer with voltage output or 4-20mA current output, e.g. gas, pressure, temperature, flow, humidity, fire, smoke.

Inbuilt visual alarms: Green – Healthy Amber – Fault Red – Alarm Inbuilt audible alarm Alphanumeric display Pushbutton facilities for: Dual level alarms Configuration Calibration Menu options Minimum eight hours backup from optional battery. Interface to plant provided by voltage-free DPCO relay contacts for Alarm 1, Alarm 2 and Fault. Two independent switched supplies for external audible and visual alarms. Lockable steel enclosure waterproof and dustproof to IP66. Fitted with pre-prepared gland entries. Water and dust proof to IP66.

Mechanical Specifications

Enclosure Material Bayblend (ABS and Polycarbonate blending)

Optional marine version : This version is housed in a cast Aluminium enclo-sure .

Format

Slim wall mounting cabinet

Dimensions 249mm x 268mm x 200mm

Weights 4 kgs

Operating voltages

110 – 120v AC 50-60Hz

220 – 240v AC 50-60Hz

20 – 28v DC

24 volt common out-puts (open collector)

Output one for external audible alarm (200ma maximum)

Output two for external visual alarm (200ma maximum)

Relays

Relay one operates when Alarm Level 1 is encountered

Relay two operates when Alarm Level 2 is encountered

Relay three operates when a fault condition occurs

LED indicators

Green LED indication of POWER ON

Red LED indication of ALARM CONDITION

Yellow LED indication of FAULT CONDITION

Visual indication unit

Green indication status : healthy

Red indication status : alarm

Yellow indication status : fault / mains fail

The input circuit is designed to accept virtually all sensor configurations available. It can be connected to any sensor with either of the following characteristics:-

Input formats

Current loop 4-20mA, internal or external variable 5-24v (source)

Current loop 4-20mA, internal or external (sink)

3 – wire pellistor

Voltage input

Output formats

4-20mA current source proportional to detected signal

4-20mA current sink proportional to detected signal

0-5v voltage output proportional to detected signal

Universal input/output card with optional isolating barriers

16 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

I n t e r n a l S a f e t y B a r r i e r U n i t

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

Accessories

17 Modcon Systems International [email protected]

www.modcon-systems.com

For applications where the gas detector head (or other sensor type) is sited in a potentially explosive atmosphere, a safety barrier must be fitted in order to limit the maximum voltage and current under a fault condition (e.g. short cir-cuit) such that an incendive spark cannot be created. Where suitable*, the internal safety barrier shown above may be fitted within the control unit. This can either be fitted at the time of manufacture (where requested) or at a later time if the system is extended by the installation of additional detectors.

* Note that some installations may necessitate the use of external barriers sited at the safe area/hazardous area inter-face - see the accessories page.

LC COMMERCIAL SERIES ~ 1 t o 4 c h a n n e l c o n t r o l u n i t s

FEATURES INCLUDE: LC1 provides 1 monitoring channel LC2 provides 2 monitoring channels LC4 provides 4 monitoring channels Lockable, wall mounting steel enclosure powder coated to RAL7035 IP65 Graphic display simultaneously showing reading for each channel and sensor type Visual indicators for alarm, fault and power Full calibration menu via push buttons on front panel Each channel can accept:

o 2-wire current source 4-20mA o 3-wire power plus current source 4-20mA o 3-wire pellistor systems

and output: o 4-20mA current source proportional to the detected signal o 4-20mA current sink proportional to the detected signal o 0-5V voltage output proportional to the detected signal

2 Alarm relays per channel 1 Common fault relay

24 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

25 Modcon Systems International [email protected]

www.modcon-systems.com

Technical Characteristic

Input Modules

Number of channels 4 max

Signal Inputs 8 Max

4-20mA Current Loop from 24V source.

4-20mA Current Loop sink to 0V.

3-Wire Pellistor Systems.

Analogue Output 8 Max

4-20mA Current source proportional to detected signal.

4-20mA Current sink proportional to detected signal.

1-5V Voltage output proportional to detected signal.

Relays – 18 Max

Contacts

Rating

1 relay assigned to alarm level 1 - channels 1 to 8.

1 relay assigned to alarm level 2 - channels 1 to 8.

1 relay assigned to common alarm level 3.

1 relay assigned to fault condition.

Single Pole Changeover Contacts (voltage free).

5A 240V AC.

Technical Characteristic

Mechanical Specifications

Size 188 x 160 x 106 (LC1), 280 x 219 x 156 (LC2), 390 x 316 x 167(LC4)

Weight 1Kg(LC1),1.9Kg(LC2), 3.8Kg(LC4)

Operating Conditions

Operating Temp -10ºC to +50ºC

Storage Temp -20ºC to +50ºC

Humidity Range 0 to 95% R.H. Non-condensing

Input Voltage 18-28V DC, or 100-240V AC 50/60

Environmental Rating IP65

26 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

27 Modcon Systems International [email protected]

www.modcon-systems.com

LC COMMERCIAL SERIES ~ 8 c h a n n e l c o n t r o l u n i t

FEATURES INCLUDE: Lockable, wall mounting steel enclosure powder coated to RAL7035 IP65 Graphic display simultaneously showing reading for each channel and sensor type Visual indicators for alarm, fault and power Full calibration menu via push buttons on front panel Each channel can accept:

o 2-wire current source 4-20mA o 3-wire power plus current source 4-20mA o 3-wire pellistor systems

and output: o 4-20mA current source proportional to the detected signal o 4-20mA current sink proportional to the detected signal o 0-5V voltage output proportional to the detected signal

2 Alarm relays per channel 1 Common fault relay

Technical Characteristic

User Interface

Display

Keyboard 4 button multifunction keypad

LED Indications Option 1

Red : Indicates alarm condition.

Yellow : Indicates fault condition.

Green : Indicates power ON.

LED Indications Option 2

Green : Indicates power ON

Red : Indicates alarm level 3 condition.

Red : Indicates alarm level 2 condition.

Red : Indicates alarm level 1 condition.

Yellow : Indicates fault condition.

Electrical Specifications

Fuse 1 (AC Input) T1.0A

Fuse 2 (24VDC input) T500mA

Input Modules

Number of channels 8 max

Signal Inputs 8 Max

4-20mA Current Loop from 24V source.

4-20mA Current Loop sink to 0V.

3-Wire Pellistor Systems.

Analogue Output 8 Max

4-20mA Current source proportional to detected signal.

4-20mA Current sink proportional to detected signal.

1-5V Voltage output proportional to detected signal.

Relays – 18 Max

Contacts

Rating

1 relay assigned to alarm level 1 - channels 1 to 8.

1 relay assigned to alarm level 2 - channels 1 to 8.

1 relay assigned to common alarm level 3.

1 relay assigned to fault condition.

Single Pole Changeover Contacts (voltage free).

5A 240V AC.

28 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

29 Modcon Systems International [email protected]

www.modcon-systems.com

Technical Characteristic

Mechanical Specifications

Size 500mm Wide x 300mm High x 80mm Deep

Weight 7.65 kg

Operating Conditions

Operating Temp -10ºC to +50ºC

Storage Temp -20ºC to +50ºC

Humidity Range 0 to 95% R.H. Non-condensing

Input Voltage 18-28V DC, or 100-240V AC 50/60

Environmental Rating IP65

Mentor MCU4 ~ 1 t o 1 6 c h a n n e l c o n t r o l u n i t

Features Large LED backlit full-graphics display of all sixteen channels Data logging and event data logging as standard 4 master alarm relays, 3 channel relays Fully configurable relays Dedicated 24 v DC drivers for audible and visual alarms Full calibration menu via external push buttons 1 – 16 input modules available with optional built in safety barriers Lockable steel enclosure, water and dust proof to IP66 Interchangeable gland plates fitted on upper and lower face Available with optional terminal chamber Built in battery back up

30 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

ENV

IRO

NM

ENTA

L A

NA

LYSI

S SECTION - GAS DETECTORS

31 Modcon Systems International [email protected]

www.modcon-systems.com

Technical Characteristic

User Interface

Display

Keyboard 4 button multifunction keypad

LED Indications Option 1

Red : Indicates alarm condition.

Yellow : Indicates fault condition.

Green : Indicates power ON.

LED Indications Option 2

Green : Indicates power ON

Red : Indicates alarm level 3 condition.

Red : Indicates alarm level 2 condition.

Red : Indicates alarm level 1 condition.

Yellow : Indicates fault condition.

Electrical Specifications

Fuse 1 (AC Input) T1.0A

Fuse 2 (24VDC input) T500mA

Input Modules

Number of channels 8 max

Signal Inputs 8 Max

4-20mA Current Loop from 24V source.

4-20mA Current Loop sink to 0V.

3-Wire Pellistor Systems.

Analogue Output 8 Max

4-20mA Current source proportional to detected signal.

4-20mA Current sink proportional to detected signal.

1-5V Voltage output proportional to detected signal.

Relays – 18 Max

Contacts

Rating

1 relay assigned to alarm level 1 - channels 1 to 8.

1 relay assigned to alarm level 2 - channels 1 to 8.

1 relay assigned to common alarm level 3.

1 relay assigned to fault condition.

Single Pole Changeover Contacts (voltage free).

5A 240V AC.

Technical Characteristic

Mechanical Specifications

Size 500mm Wide x 300mm High x 80mm Deep

Weight 7.65 kg

Operating Conditions

Operating Temp -10ºC to +50ºC

Storage Temp -20ºC to +50ºC

Humidity Range 0 to 95% R.H. Non-condensing

Input Voltage 18-28V DC, or 100-240V AC 50/60

Environmental Rating IP65

32 Modcon Systems International [email protected]

www.modcon.ru

ENV

IRON

MEN

TAL A

NA

LYSIS

SECTION - GAS DETECTORS

[email protected] www.modcon.ru

Azerbaijan Heydar Aliyev avenue 74/17 Baku AZ 1033 tel: 99412-4929859 fax: 994-12-4929859

Israel Bornshtein St. South Akko Ind. Park, Acre 24222 tel: 972-4-9553955 fax: 972-4-9553956

Romania Aleea Emil Botta, Nr. 4, BL. M104 Sc. 2, Et. 4, Ap. 56 Sector 3 Bucharest RO-031074 tel: 40-21-3260533 fax: 40-21-3260552

Russia Перовская улица 61/2, стр. 1 Москва 111394 tel: +7 (495) 9891840 fax: +7 (495) 9891840 (9)

USA Broadway Street, Suite #1203, San Francisco, CA 94115 2000

tel: 1-917-5916880 fax: 1-360-2375906

UK St John Street London EC1V 4PY 145-157 tel: 44-207-5043626 fax: 44-207-5043626

Kazahstan 140000 г. Павлодар Ул. Кленовая 2 tel / fax: +7 (7182) 644437

Ukraine г .Харьков tel. +38057 763-14-60 fax +38057 763-00-98