Main Goals of IntraVUE
• Graphical view provides an easy to use level-one support for Industrial devices communicating on Ethernet. Easily used by plant floor resources who are not Network Experts.
• reducing time for deployment and troubleshooting of Automation Devices• providing insight for preventative maintenance • Organizing Details and information to Simply Support Activities
• Localized Network Recorder: 24 x 7 Monitoring and Data capture to:
• Capture intermittent disturbances and health of devices & connections• Provide remote viewing of one or many IntraVUE systems• Easily send captured details electronically for analysis• Generates targeted Reports to simplify and direct support actions
• Provide different details that are tailored to the responsibility and skill level of the individual:
• Maintenance Technicians • Control Engineers• Manufacturing IT and Network Professionals
4
Continuously scans a
selected network.
Provides access
of network status
anywhere
Provides visualization to any
computer on the network
Corporate
NETWORK
Plant Private NETWORK
Unit Operation
Machine
Facility
OEM Equipment
Internet / VPN
IntraVUE
Scanner Software
Operator Interface Terminal
Local Laptop
IntraVUE is an application which records network details and provides interface through a Web Server interface.
Exceeding Treshold
Loss of connectionCommunication ok
Non-Ethernet Connection
Wireless Network(Hotspot)
Device with SNMP
Color coding & Connection information
6
Hover bei Verbindungen
Displays port # on device names
Hover Feature for more connection information
7
Live & Dynamic Graphical Animation for easily locating the Fault or Disruption
Graphical View of common Plant Floor problems
Foreign device gaining
access then disconnecting
Lost Wireless
Connection
Bandwidth
Issue Switch Failure
Duplicate IP or Device move
Lost SNMP
communication
8
Device information
Link to ManualsLink to Drawings or
Maintenance LogActive Web link
Main Screen
Simple Mouse Click Opens Device Maintenance Details
Simple Mouse click opens a wealth of information
Trending Communications
Device information
Link to active Web DataCommunication Event Log
Export to Excel Reports
Trending key parameters on your Network
Display a specific attribute of a portion or all devices on the network to quickly find the source of a problem.
Duplicate IP and MAC addresses
Intermittent losses caused be noise or vibration
Devices starting to degrade in performance
Accidental loops in cabling located in remote electrical enclosures
Foreign devices connecting to the network (contractor Laptops)
Periodic shorts bursts of broadcast traffic triggered by other devices
Devices accidentally moved to a different port
Cable and connector problems based on crushed, bent , or improperly
grounded cable
Redundancy failures using Ring or RSPT
Communication module lockups or failures based on power surges
IntraVUE has proven to be effective in identifying the following
problems which are contained in the Diagnostic Reports delivered in
minutes by Email.
Single button to Document all devices on the Network in a spreadsheet
Generate a spreadsheet with IP, MAC address, and port and switch address instantly.
13
Daily KPI Report
Status
GoodNo action
Required
Bad
Skill
LevelLow
Medium
High
Diagnostic
Report Diagnostic
ReportIntraVUE
Dashboard
Diagnostic
ReportIntraVUE
Moving from Break-Fix to Pro-Active Support
14
Network KPI View provides instant Awareness to Issues affecting Critical Equipment
Technicians & Installers
Controls & Manufacturing IT
Operations Management
Daily KPI Screens can be accessed by Computer or Portable device from IntraVUE.
IntraVUE Support Archive to obtainRemote Offline Support and
Automated Diagnostic Reports
Electronically send current data collected to be analyzed (24 hours a day) with a written report generated in minutes and emailed to a computer, Tablet, or Smart Phone
Archiving, Disaster Recovery, and Remote Support
Backup to Database
Restore from Database
Capture network disturbances
Archive current network architectures
Document “As-Is” network traffic
Store performance tests
Validate installed equipment progress
Off Line Analysis and Support
Disaster recovery
Time based Comparison
Future design and Planning
Asset management
Database management• Backup • Restores• On-Line Comparisons• Off-line Analysis
17
• During Installation & Startup
• Documentation of actual network status
• Project progress and topology
• Locations of devices and programming panels
• IP Address management
• Troubleshooting
• During Operations
• Network performance
• Device communications and topology
• Device availability- sign in/ sign off
• Access to Data Archive, Reports & Analytcs
• Pre-active Mainteanance
• During Restructuring
• Compare functions before/after
• Structured re- commissioning
IntraVUE provides instant help during all phases:
18
IntraVUE application example: Mercedes
• Server based central management:Remote installation- and deployment for all stations
• LLDP Manager
Profinet topology discovery , naming, grafics
• Integra Alarm Provider
Interface to present active IntraVue alarms insideIntegra
• IntraVUE- Reportgenerator
Generation of diagnostics, event and performancereports to Mercedes standards
• German version
for Help, System Messages & Installer
• Switch managementUp/ Download of configuration and firmware
• Device BitmapsGraphical Network View generated from Integra
• CRC Checkfor all devices
• Supervisory ViewGrouping and Display Management according toplant structure
Rastatt: 120+ production cells/ subnets with >14.000 devices, Site- Licensing
19
Network scan includingProfiNet topology
ConnexSoft Proprietary & confidential© 2015 ConneXSoft
IntraVUE application example: Mercedes screenshot
20
View a live
picture of your
communications
to all the
automation
devices !
CONCLUSION: Easy to Use and Powerful Visualization Software