Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1...

17
Intra and inter-session reliability of the angle between pain onset and submaximal pain during upper limb neurodynamics test 1 A study on healthy individuals Leoni Diego Pt, MSc, OMT Storer Davide, Gatti Roberto, Egloff Michele, Barbero Marco S.I.F. National Congress, Milano 3-4 October 2015

Transcript of Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1...

Page 1: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Intra and inter-session reliability of the angle between pain onset and submaximal pain during upper limb neurodynamics test 1 A study on healthy individuals

Leoni Diego Pt, MSc, OMT Storer Davide, Gatti Roberto, Egloff Michele, Barbero Marco S.I.F. National Congress, Milano 3-4 October 2015

Page 2: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 3: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Ciao!

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 4: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Upper limb neurodynamics test 1 (ULNT1) (Butler 2000)

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 5: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Upper limb neurodynamics test 1 (ULNT1) (Butler 2000)

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 6: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Positivity of neurodynamics tests: 3 conditions

Patient’s typical complain ‘This is just my pain’

Different response between ‘To the left is more painful’

sympt- and asymptomatic side

Symptom’s change following ‘If I move my head the pain increases’

structural differentiation

(Elvey 1997, Butler 2000, Nee 2012)

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 7: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

‘Ouch!’

Pain onset (PO) (Oliver e Rushton 2010)

‘The moment when the least experience of pain is recognized’

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 8: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

‘Ouch!’ Submaximal pain (SP)

‘The moment when pain or tingling increases and the subject wants the test to be ceased’

(Oliver e Rushton 2010)

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 9: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Quantifying the mechanosensitivity: PO and SP angles of occurrence in range

(Coppieters 2002, Vanti 2010, Oliver 2011)

High intra-tester reliability

High intra-session reliability

BUT…

Few data on the inter-session reliability

Possible fault in patient positioning

between different sessions

PO SP

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 10: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

The angle between PO and SP (Δ)

Δ

Δ Angle between PO and SP PO SP

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 11: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Aim of the study

Investigate the intra- and inter-session reliability of the angle between pain onset

and submximal pain (Δ)

Explore whether the intra- and inter-session reliability of Δ was higher compared

to the reliability of PO and SP angles of occurrence

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 12: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

44 healty participants (27 females, 17 males)

Age 21.8 ± 2.3

Inclusion criteria: non painful and full active RoM of the upper quadrant’s joints

Exculsion criteria: recent od present upper quadrant pain, neurologic deseases, drugs

or alcohol abuse, spine surgery, radiation therapy or chemotherapy in the past year

Wrist&hand splint, shoulder positioning device, electromagnetic goniometer

Intraclass Correlation Coefficient (ICC 3,1) and Bland-Altman plots

Materials and methods

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 13: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Procedures

I session II session (24h after)

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 14: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Results: ICC values

asf ICC (upper; lower bounds)

∆ Pain Onset Submaximal Pain

Intra-session 0.71 [0.47 ; 0.85] 0.46 [0.11 ; 0.70) 0.55 [0.23 ; 0.76]

Inter-session 0.79 [0.60 ; 0.89] 0.64 [0.37 ; 0.81] 0.48 [0.15 ; 0.72]

ICC interpretation criteria: 0.00-0.25: no correlation; 0.26-0.49: low correlation; 0.50-0.69: moderate

correlation; 0.70-0.89: high correlation; 0.90-1.00: very high correlation (Munro 2005)

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 15: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Results: Bland-Altman plots

Intra-session Inter-session

asf B-A plots - mean difference (95% limits of agreement)

∆ (°) Pain Onset (°) Submaximal Pain (°)

Intra-session 2.3 [-18.3 ; 23.1] 2,5 [-33.9 ; 28.8] 0,1 [-26.8 ; 26.5]

Inter-session 2.8 [-14.7 ; 20.4] 5,3 [-30.7 ; 19.9] -2.5 [-29.2 ; 24.1]

DEASS / ULNT1 reliability

S.I.F. Congress, Milano 3-4 October 2015

Page 16: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Discussion and conclusions

DEASS / ULNT1 reliability

The intra- and inter-session reliability of the angle between PO and SP during the ULNT1

in healthy individuals:

  resulted high

  is higher compared to the reliability of PO and SP angles of occurrence

The ∆ might be the preferable variable in the assessment of neural mechanosensitivity

Further research should test the ∆ reliability in the clinical setting

S.I.F. Congress, Milano 3-4 October 2015

Page 17: Intra and inter-session reliability of the angle between pain …repository.supsi.ch/6795/3/ULNT1 reliability_slide... · 2015-10-04 · Upper limb neurodynamics test 1 (ULNT1) (Butler

DEASS / Pain drawing and pain location reliability

Thanks for your attention...

DEASS / ULNT1 reliability

[email protected]