Interpreter Desk
description
Transcript of Interpreter Desk
1 DCNNG SA PO INST/PRM3-EU | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems DCN Next GenDCN Next Gen
Interpreter Desk
2 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter Desk Incoming part
6
5
4 3 2 1
1 Floor keyTo toggle between floor and auto-relay.
Next to the key are two green LEDs that indicate whether floor or auto-relay has been selected.
2 LoudspeakerThe loudspeaker is only active when
the microphones of all interpreter desks in the same booth are off.
3 Loudspeaker volume control
4 Headphones volume control
5 Bass control of the headphones.
6 Treblecontrol of the headphones.
I&U Instructions
3 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter Desk Incoming part
9 107 8 7 Beep
A key to toggle on and off audio beeps. This function is intended for blind
interpreters.
8 Select knobA rotary push button to program and
operate the desk.
9 LCD DisplayA 264x32 pixel graphic LCD display is
used as an interactive display to program and operate the desk.
10 Five Pre select KeysFor quick access to pre selected
incoming channels.
I&U Instructions
4 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter DeskOutgoing part
12
14 15
11 13 11 LCD Display
Outgoing channels and speech time indication.
12 Microphone connectorfor connecting a pluggable microphone of DCN type.
13 Output selectionTwo keys to select the output. Each output has anEngaged LED to indicate which channel is engaged.
14 Micro key to toggle between microphone on and microphone off. If the microphone is on, a red LED ring around the key lights up. If all microphones in the booth are off, a green LED ring around the key lights up.
15 Mutekey to mute the microphone as long as it is pressed.
I&U Instructions
5 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter DeskOutgoing part
16 17
1920
18
16 Telephone call indicatorA yellow LED that indicates incoming phone
calls from an external telephone system.
17 Intercom call indicatorA yellow LED that indicates incoming external
and internal intercom calls.
18 Message buttonOpens text messages that are sent to the
interpreter desk. When the interpreter desk receives a message, the yellow LED adjacent to the message button blinks.
19 Call button (Intercom call to operator) Opens an intercom channel to the operator.
20 Chair button (Intercom call chairman)Opens an intercom channel to the Chairman.
I&U Instructions
6 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter DeskOutgoing part
2221
21 Slowlybutton (Speak slowly) Key to activate an external indicator via a Data
Distribution Board with address 253 to request the
current speaker to speak slower.
22 Help button (silent request to help) signalingKey to activate an external indicator via a DataDistribution Board with address 254-255 to requestfor help.
I&U Instructions
7 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
DDB used for speak slowly signaling.
Booth and desk # not important. The first activated Slow action activates the first bit DOO. When more Slow actions are activated at the same time more bits are activated. (max. 8)
Push on Slow button
I&U Instructions
8 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
DDB used for Help signaling.
Push on Help button
Booth 3 desk #
Desk # not important. The first activated Help action within the booth activates the corresponding bit.
I&U Instructions
9 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter Desk side view
22 Headphones socket (for 6.3 mm jack) Intended for connecting stereo
headphones.
23 Headset socket A 5 pole 180 degrees DIN socket intended
for IEC 268-11 compliant headsets.
24 Headphones socket (for 3.5 mm jack) Intended for connecting stereo
headphones.
2324
22
I&U Instructions
10 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter Desk bottom view
25 DCN cable2 m long cable with a male connector.
26 External devicesAn RJ45 socket to connect a booth-on-air indication and to connect to devices that can activate the telephone and intercom indicators on the desk.
27 DCN socket A female socket to loop-through.
26
27
25
I&U Instructions
11 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter Desk bottom view
28 De-initA recessed micro switch to reset the address of the unit.
29 Microphone volumeA recessed potentiometer to adjust the volume of the microphone from -2 dB to 2 dB.
The potentiometer adjusts the volumes of both the microphone connected to the desk and the microphone of the headset.
2829
I&U Instructions
12 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter Desk Normal Interpretation
Floor Active
I&U Instructions
13 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter Desk Relay Interpretation
1
Auto-relay active
I&U Instructions
14 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Quick Reference Card
Quick Reference
15 DCNNG SA PO INST/SEU-CO | |02.Mar.06 © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of
disposal such as copying and passing on to third parties.
Security Systems
Interpreter Desk
End of section
SA PO Menu