STAAD.Pro 2006 is a suite of proprietary computer programs of Research Engineers, a Bentley Solutions Center. Although every effort has been made to ensure the correctness of these programs, REI will not accept responsibility for any mistake, error or misrepresentation in or as a result of the usage of these programs.

RELEASE 2006

© 2006 Bentley Systems, Incorporated. All Rights Reserved.

Published March, 2006

Page 3: International Design Codes

About STAAD.Pro

STAAD.Pro is a general purpose structural analysis and design program with applications primarily in the building industry - commercial buildings, bridges and highway structures, industrial structures, chemical plant structures, dams, retaining walls, turbine foundations, culverts and other embedded structures, etc. The program hence consists of the following facilities to enable this task. 1. Graphical model generation utilities as well as text editor based commands for

creating the mathematical model. Beam and column members are represented using lines. Walls, slabs and panel type entities are represented using triangular and quadrilateral finite elements. Solid blocks are represented using brick elements. These utilities allow the user to create the geometry, assign properties, orient cross sections as desired, assign materials like steel, concrete, timber, aluminum, specify supports, apply loads explicitly as well as have the program generate loads, design parameters etc.

2. Analysis engines for performing linear elastic and pdelta analysis, finite element analysis, frequency extraction, and dynamic response (spectrum, time history, steady state, etc.).

3. Design engines for code checking and optimization of steel, aluminum and timber members. Reinforcement calculations for concrete beams, columns, slabs and shear walls. Design of shear and moment connections for steel members.

4. Result viewing, result verification and report generation tools for examining displacement diagrams, bending moment and shear force diagrams, beam, plate and solid stress contours, etc.

5. Peripheral tools for activities like import and export of data from and to other widely accepted formats, links with other popular softwares for niche areas like reinforced and prestressed concrete slab design, footing design, steel connection design, etc.

6. A library of exposed functions called OpenSTAAD which allows users to access STAAD.Pro’s internal functions and routines as well as its graphical commands to tap into STAAD’s database and link input and output data to third-party software written using languages like C, C++, VB, VBA, FORTRAN, Java, Delphi, etc. Thus, OpenSTAAD allows users to link in-house or third-party applications with STAAD.Pro.

Page 4: International Design Codes

About the STAAD.Pro Documentation The documentation for STAAD.Pro consists of a set of manuals as described below. These manuals are normally provided only in the electronic format, with perhaps some exceptions such as the Getting Started Manual which may be supplied as a printed book to first time and new-version buyers. All the manuals can be accessed from the Help facilities of STAAD.Pro. Users who wish to obtain a printed copy of the books may contact Research Engineers. REI also supplies the manuals in the PDF format at no cost for those who wish to print them on their own. See the back cover of this book for addresses and phone numbers. Getting Started and Tutorials : This manual contains information on the contents of the STAAD.Pro package, computer system requirements, installation process, copy protection issues and a description on how to run the programs in the package. Tutorials that provide detailed and step-by-step explanation on using the programs are also provided. Examples Manual This book offers examples of various problems that can be solved using the STAAD engine. The examples represent various structural analyses and design problems commonly encountered by structural engineers. Graphical Environment This document contains a detailed description of the Graphical User Interface (GUI) of STAAD.Pro. The topics covered include model generation, structural analysis and design, result verification, and report generation. Technical Reference Manual This manual deals with the theory behind the engineering calculations made by the STAAD engine. It also includes an explanation of the commands available in the STAAD command file. International Design Codes This document contains information on the various Concrete, Steel, and Aluminum design codes, of several countries, that are implemented in STAAD. The documentation for the STAAD.Pro Extension component(s) is available separately.

Page 5: International Design Codes

Table of Contents

International Codes

Introduction i

Section 1 Australian Codes 1-

1A Concrete Design Per AS3600-2001 1-1 1A.1 Design Operations 1-1 1A.2 Section Types for Concrete Design 1-1 1A.3 Member Dimensions 1-1 1A.4 Design Parameters 1-2 1A.5 Slenderness Effects and Analysis Consideration 1-2 1A.6 Beam Design 1-3 1A.7 Column Design 1-5 1A.8 Slab/Wall Design 1-6

1B Steel Design Per AS4100-1998 1-9 1B.1 General 1-9 1B.2 Analysis Methodology 1-10 1B.3 Member Property Specifications 1-10 1B.4 Built-in Steel Section Library 1-10 1B.5 Section Classification 1-15 1B.6 Member Resistances 1-15 1B.7 Design Parameters 1-17 1B.8 Code Checking 1-20 1B.9 Member Selection 1-20 1B.10 Tabulated Results of Steel Design 1-21

Section 2 British Codes 2-

2A Concrete Design Per BS8100 2-1 2A.1 Design Operations 2-1 2A.2 Design Parameters 2-1 2A.3 Slenderness Effects and Analysis Considerations 2-4 2A.4 Member Dimensions 2-4 2A.5 Beam Design 2-5 2A.6 Column Design 2-7 2A.7 Slab Design 2-8 2A.8 Shear Wall Design 2-10

Page 6: International Design Codes

2B Steel Design Per BS5950:2000 2-23 2B.1 General 2-23 2B.2 Analysis Methodology 2-25 2B.3 Member Property Specifications 2-25 2B.4 Built-in Steel Section Library 2-25 2B.5 Member Capacities 2-30 2B.6 Design Parameters 2-34 2B.7 Design Operations 2-46 2B.8 Code Checking 2-46 2B.9 Member Selection 2-47 2B.10 Tabulated Results of Steel Design 2-48 2B.11 Plate Girders 2-49 2B.12 Composite Sections 2-50 2B.13 Design of Tapered Beams 2-50

2B1 Steel Design Per BS5950:1990 2-55

2B1.1 General 2-55 2B1.2 Analysis Methodology 2-56 2B1.3 Member Property Specifications 2-56 2B1.4 Built-in Steel Section Library 2-56 2B1.5 Member Capacities 2-60 2B1.6 Design Parameters 2-65 2B1.7 Design Operations 2-73 2B1.8 Code Checking 2-74 2B1.9 Member Selection 2-74 2B1.10 Tabulated Results of Steel Design 2-75 2B1.11 Plate Girders 2-76 2B1.12 Composite Sections 2-77

2C Design Per BS5400 2-79 2C.1 General Comments 2-79 2C.2 Shape Limitations 2-79 2C.3 Section Class 2-80 2C.4 Moment Capacity 2-80 2C.5 Shear Capacity 2-80 2C.6 Design Parameters 2-81 2C.7 Composite Sections 2-82

2D Design Per BS8007 2-85 2D.1 General Comments 2-85 2D.2 Design Process 2-85 2D.3 Design Parameters 2-87 2D.4 Structural Model 2-87

Page 7: International Design Codes

2D.5 Wood & Armer Moments 2-88

2E Design Per British Cold Formed Steel Code 2-91 2E.1 General 2-91 2E.2 Cross-sectional Properties 2-91 2E.3 Design Procedure 2-92 2E.4 Design Equations 2-93 2E.5 Verification Problem 2-101

Section 3 Canadian Codes 3-

3A Concrete Design Per CSA Standard A 23.3 94 3-1 3A.1 Design Operations 3-1 3A.2 Section Types for Concrete Design 3-1 3A.3 Member Dimensions 3-1 3A.4 Slenderness Effects and Analysis Consideration 3-2 3A.5 Design Parameters 3-3 3A.6 Beam Design 3-4 3A.7 Column Design 3-7 3A.8 Slab/Wall Design 3-7

3B Steel Design Per CSA Standard CAN/CSA – S16-01 3-9

3B.1 General Comments 3-9 3B.2 Analysis Methodology 3-10 3B.3 Member Property Specifications 3-10 3B.4 Built-in Steel Section Library 3-10 3B.5 Section Classification 3-17 3B.6 Member Resistances 3-17 3B.7 Design Parameters 3-21 3B.8 Code Checking 3-23 3B.9 Member Selection 3-24 3B.10 Tabulated Results of Steel Design 3-25 3B.11 Verification Problems 3-26

3C Design Per Canadian Cold Formed Steel Code 3-41

3C.1 General 3-41 3C.2 Cross-Sectional Properties 3-41 3C.3 Design Procedure 3-42

Page 8: International Design Codes

3D Wood Design Per CSA Standard CAN/CSA-086-01 3-49

3D.1 General Comments 3-49 3D.2 Analysis Methodology 3-50 3D.3 Member Property Specifications 3-50 3D.4 Built-in Section Library 3-50 3D.5 Member Resistance 3-54 3D.6 Design Parameters 3-57 3D.7 Code Checking 3-59 3D.8 Member Selection 3-60 3D.9 Tabulated Results of Timber Design 3-60 3D.10 Verification Problems 3-61

Section 4 Chinese Codes 4-

4A Concrete Design Per GBJ 10-89 4-1 4A.1 Design Operations 4-1 4A.2 Section Types for Concrete Design 4-1 4A.3 Member Dimensions 4-1 4A.4 Design Parameters 4-2 4A.5 Beam Design 4-2 4A.6 Column Design 4-6

4B Steel Design Per GBJ 17-88 4-11 4B.1 General 4-11 4B.2 Analysis Methodology 4-12 4B.3 Member Property Specifications 4-12 4B.4 Built-in Chinese Steel Section Library 4-12 4B.5 Member Capacities 4-17 4B.6 Combined Loading 4-18 4B.7 Design Parameters 4-18 4B.8 Code Checking 4-18 4B.9 Member Selection 4-19

Section 5 European Codes 5-

5A Concrete Design Per Eurocode EC2 5-1 5A.1 Design Operations 5-1 5A.2 Eurocode 2 (EC2) 5-1 5A.3 National Application Documents 5-2 5A.4 Material Properties and Load Factors 5-2 5A.5 Columns 5-3

Page 9: International Design Codes

5A.6 Beams 5-3 5A.7 Slabs 5-5 5A.8 Design Parameters 5-5 5A.9 Parameter Definition Table 5-6

5B Steel Design Per Eurocode EC3 5-9 5B.1 General Description 5-9 5B.2 Design Parameters 5-14 5B.3 Worked Examples 5-20 5B.4 User’s Examples 5-37

5C Timber Design Per EC5 Part 1-1 5-45 5C.1 General Comments 5-45 5C.2 Analysis Methodology 5-49 5C.3 Design Parameters 5-58 5C.4 Verification Problems 5-61

Section 6 French Codes 6-

6A Concrete Design Per B A E L 6-1 6A.1 Design Operations 6-1 6A.2 Design Parameters 6-1 6A.3 Slenderness Effects and Analysis Consideration 6-1 6A.4 Member Dimensions 6-2 6A.5 Beam Design 6-3 6A.6 Column Design 6-5 6A.7 Slab/Wall Design 6-5

6B Steel Design Per the French Code 6-7 6B.1 General Comments 6-7 6B.2 Basis Of Methodology 6-8 6B.3 Member Capacities 6-8 6B.4 Combined Axial Force and Bending 6-9 6B.5 Design Parameters 6-9 6B.6 Code Checking and Member Selection 6-9 6B.7 Tabulated Results of Steel Design 6-9 6B.8 Built-in French Steel Section Library 6-12

Page 10: International Design Codes

Section 7 German Codes 7-

7A Concrete Design Per DIN 1045 7-1 7A.1 Design Operations 7-1 7A.2 Section Types for Concrete Design 7-1 7A.3 Member Dimensions 7-1 7A.4 Slenderness Effects and Analysis Considerations 7-2 7A.5 Beam Design 7-3 7A.6 Column Design 7-5 7A.7 Slab Design 7-6 7A.8 Design Parameters 7-7

7B Steel Design Per the DIN Code 7-11 7B.1 General 7-11 7B.2 Analysis Methodology 7-12 7B.3 Member Property Specifications 7-12 7B.4 Built-in German Steel Section Library 7-12 7B.5 Member Capacities 7-17 7B.6 Combined Loading 7-18 7B.7 Design Parameters 7-19 7B.8 Code Cecking 7-21 7B.9 Member Selection 7-22

Section 8 Indian Codes 8-

8A Concrete Design Per IS456 8-1 8A.1 Design Operations 8-1 8A.2 Section Types for Concrete Design 8-1 8A.3 Member Dimensions 8-1 8A.4 Design Parameters 8-2 8A.5 Slenderness Effects and Analysis Consideration 8-2 8A.6 Beam Design 8-3 8A.7 Column Design 8-7 8A.8 Bar Combination 8-13 8A.9 Wall Design in accordance with IS 456-2000 8-14

8A1 Concrete Design Per IS13920 8-27 8A1.1 Design Operations 8-27 8A1.2 Section Types for Concrete Design 8-27 8A1.3 Design Parameters 8-28 8A1.4 Beam Design 8-28

Page 11: International Design Codes

8A1.5 Column Design 8-32 8A1.6 Bar Combination 8-43

8B Steel Design Per IS800 8-49 8B.1 Design Operations 8-49 8B.2 General Comments 8-50 8B.3 Allowable Stresses 8-50

8B.3.1 Axial Stress 8-51 8B.3.2 Bending Stress 8-52 8B.3.3 Shear Stress 8-53 8B.3.4 Combined Stress 8-54

8B.4 Design Parameters 8-54 8B.5 Stability Requirements 8-54 8B.6 Truss Members 8-55 8B.7 Deflection Check 8-55 8B.8 Code Checking 8-55 8B.9 Member Selection 8-56 8B.10 Member Selection by Optimization 8-56 8B.11 Tabulated Results of Steel Design 8-57 8B.12 Indian Steel Table 8-59 8B.13 Column with Lacings and Battens 8-67

8C Steel Design Per IS802 8-71 8C.1 General Comments 8-71 8C.2 Allowable Stresses 8-71

8C.2.1 Axial Stress 8-72 8C.3 Stability Requirements 8-74 8C.4 Minimum Thickness Requirement 8-76 8C.5 Code Checking 8-76

8C.5.1 Design Steps 8-77 8C.6 Member Selection 8-78 8C.7 Member Selection by Optimization 8-78 8C.8 Tabulated Results of Steel Design 8-79 8C.9 Parameter Table for IS802 8-81 8C.10 Calculation of Net Section Factor 8-83 8C.11 Example Problem No. 28 8-85

8D Design Per Indian Cold Formed Steel Code 8-93 8D.1 General 8-93 8D.2 Cross-Sectional Properties 8-93 8D.3 Design Procedure 8-94

Page 12: International Design Codes

Section 9 Japanese Codes 9-

9A Concrete Design Per AIJ 9-1 9A.1 Design Operations 9-1 9A.2 Section Types for Concrete Design 9-1 9A.3 Member Dimensions 9-1 9A.4 Slenderness Effects and Analysis Consideration 9-2 9A.5 Beam Design 9-3 9A.6 Column Design 9-5 9A.7 Slab/Wall Design 9-7 9A.8 Design Parameters 9-8

9B Steel Design Per AIJ 9-11 9B.1 General 9-11 9B.2 Analysis Methodology 9-12 9B.3 Member Property Specifications 9-12 9B.4 Built-in Japanese Steel Section Library 9-12 9B.5 Member Capacities 9-18 9B.6 Combined Loading 9-22 9B.7 Design Parameters 9-23 9B.8 Code Checking 9-25 9B.9 Member Selection 9-26

Section 10 Mexican Codes 10-

10A Concrete Design Per MEX NTC 1987 10-1 10A.1 Design Operations 10-1 10A.2 Section Types for Concrete Design 10-1 10A.3 Member Dimensions 10-2 10A.4 Design Parameters 10-3 10A.5 Beam Design 10-6 10A.6 Column Design 10-10 10A.7 Column Interaction 10-11 10A.8 Column Design Output 10-12 10A.9 Slab Design 10-13

10B Steel Design Per Mexican Code 10-15 10B.1 General 10-15 10B.2 Limit States Design Fundamentals 10-16 10B.3 Member End Forces and Moments 10-17 10B.4 Section Classification 10-18

Page 13: International Design Codes

10B.5 Member in Axial Tension 10-18 10B.6 Axial Compression 10-19 10B.7 Flexural Design Strength 10-20 10B.8 Design for Shear 10-22 10B.9 Combined Compression Axial Force and Bending 10-22 10B.10 Combined Tension Axial Force and Bending 10-22 10B.11 Design Parameters 10-23 10B.12 Code Checking and Member Selection 10-25 10B.13 Tabulated Results of Steel Design 10-26

Section 11 Russian Codes 11-

11A Concrete Design Per Russian Code 11-1 11A.1 General 11-1 11A.2 Input Data 11-3 11A.3 Beams 11-10 11A.4 Columns 11-16 11A.5 2D (two dimensional) element (slabs, walls, shells) 11-21

11B Steel Design Per Russian Code 11-25 11B.1 General 11-25 11B.2 Axial tension members 11-26 11B.3 Axial compression members 11-26 11B.4 Flexural members 11-27 11B.5 Eccentrical compression/tension members 11-28 11B.6 Input Data 11-29 11B.7 Section selection and check results 11-45

Section 12 South African Codes 12-

12A Concrete Design Per SABS 0100-1 12-1 12A.1 Design Operations 12-1 12A.2 Design Parameters 12-1 12A.3 Member Dimensions 12-3 12A.4 Beam Design 12-4 12A.5 Column Design 12-6

12B Steel Design Per SAB Standard SAB0162–1: 1993 12-9 12B.1 General 12-9 12B.2 Analysis Methodology 12-10 12B.3 Member Property Specifications 12-10 12B.4 Built-in Steel Section Library 12-10 12B.5 Section Classification 12-16

Page 14: International Design Codes

12B.6 Member Resistances 12-16 12B.7 Design Parameters 12-20 12B.8 Code Checking 12-22 12B.9 Member Selection 12-24 12B.10 Tabulated Results of Steel Design 12-24 12B.11 Verification Problems 12-26

Section 13 American Aluminum Code 13-

13A Design Per American Aluminum Code 13-1 13.1 General 13-1 13.2 Member Properties 13-1 13.3 Design Procedure 13-3 13.4 Design Parameters 13-4 13.5 Code Checking 13-8 13.6 Member Selection 13-8

Section 14 American Transmission Tower Code 14-

14A Steel Design Per ASCE 10-97 14-1 14A.1 General Comments 14-1 14A.2 Allowable Stresses Per ASCE 10-97 14-2 14A.3 Critical conditions used as criteria to determine Pass/Fail status 14-3 14A.4 Design Parameters 14-3 14A.5 Code Checking and Member Selection 14-3

14B Steel Design Per ASCE Manuals And Reports 14-7 14B.1 General Comments 14-7 14B.2 Allowable Stresses Per ASCE (Pub.52) 14-8 14B.3 Design Parameters 14-9 14B.4 Code Checking and Member Selection 14-9 14B.5 Parameter Definition Table 14-10

Section 15 American A.P.I. Code 15-

15 Steel Design Per API 15-1 15.1 Design Operations 15-1 15.2 Allowables Per API Code 15-2

15.2.1 Tension Stress 15-2 15.2.2 Beam Stress 15-2

15.3 Stress due to Compression 15-3 15.4 Bending Stress 15-3

Page 15: International Design Codes

15.5 Combined Compression and Bending 15-4 15.6 Design Parameters 15-4 15.7 Code Checking 15-7 15.8 Member Selection 15-7 15.9 Truss Members 15-8 15.10 Punching Shear 15-8 15.11 Generation of Geometry File 15-9 15.12 Chord Selection and Qf Parameter 15-10 15.13 External Geometry File 15-11 15.15 Limitations 15-12 15.15 Tabulated Results of Steel Design 15-13 15.16 The Two-Step Process 15-14

Page 16: International Design Codes
Page 17: International Design Codes

Introduction

This publication has been prepared to provide information pertaining to the various international codes supported by STAAD. These codes are provided as additional codes by Research Engineers. In other words, they do not come with the standard package. Hence, information on only some of the codes presented in this document may be actually pertinent to the individual user's package. Users may locate the information for the appropriate code by referring to the Table of Contents shown on the previous few pages. This document is to be used in conjunction with the STAAD Technical Reference Manual and the STAAD Examples Manual. Effort has been made to provide some basic information about the analysis considerations and the logic used in the design approach. A brief outline of the factors affecting the design along with references to the corresponding clauses in the codes is also provided. Examples are provided at the appropriate places to facilitate ease of understanding of the usage of the commands and design parameters. Users are urged to refer to the Examples Manual for solved problems that use the commands and features of STAAD. Since the STAAD output contains references to the clauses in the code that govern the design, users are urged to consult the documentation of the code of that country for additional details on the design criteria.

Page 18: International Design Codes

A;lsdflsakf

Page 19: International Design Codes

Section 1 Australian Codes

Page 20: International Design Codes

;asd;ljf’lksa

Page 21: International Design Codes

1-1

Concrete Design Per AS3600 - 2001

Section 1A

1A.1 Design Operations

STAAD has the capabilities for performing concrete design based on the Australian code AS3600-2001 Australian Standard-Concrete Structures.

1A.2 Section Types for Concrete Design

The following types of cross sections for concrete members can be designed. For Beams Prismatic (Rectangular & Square) For Columns Prismatic (Rectangular, Square and Circular)

1A.3 Member Dimensions

Concrete members which will be designed by the program must have certain section properties input under the MEMBER PROPERTY command. The following example shows the required input:

Page 22: International Design Codes

Concrete Design Per AS 3600

Section 1A 1-2

UNIT MM MEMBER PROPERTY 1 3 TO 7 9 PRISM YD 450. ZD 250. 11 13 PR YD 350.

In the above input, the first set of members are rectangular (450 mm depth and 250mm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with 350 mm diameter. It is absolutely imperative that the user not provide the cross section area (AX) as an input.

1A.4 Design Parameters

The program contains a number of parameters which are needed to perform the design. Default parameter values have been selected such that they are frequently used numbers for conventional design requirements. These values may be changed to suit the particular design being performed. Table 1A.1 of this manual contains a complete list of the available parameters and their default values. It is necessary to declare length and force units as Millimeter and Newton before performing the concrete design.

1A.5 Slenderness Effects and Analysis Consideration

Slenderness effects are extremely important in designing compression members. There are two options by which the slenderness effect can be accommodated. One option is to perform an exact analysis which will take into account the influence of axial loads and variable moment of inertia on member stiffness and fixed end moments, the effect of deflections on moment and forces and the effect of the duration of loads. Another option is to approximately magnify design moments.

Page 23: International Design Codes

Section 1A 1-3

STAAD has been written to allow the use of the first option. To perform this type of analysis, use the command PDELTA ANALYSIS instead of PERFORM ANALYSIS. The PDELTA ANALYSIS will accommodate the requirements of the second- order analysis described by AS 3600, except for the effects of the duration of the loads. It is felt that this effect may be safely ignored because experts believe that the effects of the duration of loads is negligible in a normal structural configuration. Although ignoring load duration effects is somewhat of an approximation, it must be realized that the evaluation of slenderness effects is also by an approximate method. In this method, additional moments are calculated based on empirical formula and assumptions on sidesway. Considering all of the above information, a PDELTA ANALYSIS, as performed by STAAD may be used for the design of concrete members. However the user must note that to take advantage of this analysis, all the combinations of loading must be provided as primary load cases and not as load combinations. This is due to the fact that load combinations are just algebraic combinations of forces and moments, whereas a primary load case is revised during the P-delta analysis based on the deflections. Also, note that the proper factored loads (like 1.5 for dead load etc.) should be provided by the user. STAAD does not factor the loads automatically.

1A.6 Beam Design

Beams are designed for flexure, shear and torsion. For all these forces, all active beam loadings are prescanned to identify the critical load cases at different sections of the beams. The total number of sections considered is 13( e.g. 0.,.1,.2,.25,.3,.4,.5,.6,.7,. 75,.8,.9 and 1). All of these sections are scanned to determine the design force envelopes.

Page 24: International Design Codes

Concrete Design Per AS 3600

Section 1A 1-4 Design for Flexure Maximum sagging (creating tensile stress at the bottom face of the beam) and hogging (creating tensile stress at the top face) moments are calculated for all active load cases at each of the above mentioned sections. Each of these sections are designed to resist both of these critical sagging and hogging moments. Currently, design of singly reinforced sections only is permitted. If the section dimensions are inadequate as a singly reinforced section, such a message will be permitted in the output. Flexural design of beams is performed in two passes. In the first pass, effective depths of the sections are determined with the assumption of single layer of assumed reinforcement and reinforcement requirements are calculated. After the preliminary design, reinforcing bars are chosen from the internal database in single or multiple layers. The entire flexure design is performed again in a second pass taking into account the changed effective depths of sections calculated on the basis of reinforcement provided after the preliminary design. Final provision of flexural reinforcements are made then. Efforts have been made to meet the guideline for the curtailment of reinforcements as per AS 3600. Although exact curtailment lengths are not mentioned explicitly in the design output (finally which will be more or less guided by the detailer taking into account of other practical consideration), user has the choice of printing reinforcements provided by STAAD at 13 equally spaced sections from which the final detailed drawing can be prepared. Design for Shear

Shear reinforcement is calculated to resist both shear forces and torsional moments. Shear design is performed at 13 equally spaced sections (0.to 1.) for the maximum shear forces amongst the active load cases and the associated torsional moments. Shear capacity calculation at different sections without the shear reinforcement is based on the actual tensile reinforcement provided by STAAD program. Two-legged stirrups are provided to take care of the balance shear forces acting on these sections.

Page 25: International Design Codes

Section 1A 1-5

Example of Input Data for Beam Design UNIT NEWTON MMS START CONCRETE DESIGN CODE AUSTRALIAN FYMAIN 415 ALL FYSEC 415 ALL FC 35 ALL CLEAR 25 MEM 2 TO 6 MAXMAIN 40 MEMB 2 TO 6 TRACK 1.0 MEMB 2 TO 9 DESIGN BEAM 2 TO 9 END CONCRETE DESIGN

1A.7 Column Design

Columns are designed for axial forces and biaxial moments at the ends. All active load cases are tested to calculate reinforcement. The loading which yields maximum reinforcement is called the critical load. Column design is done for square, rectangular and circular sections. By default, square and rectangular columns are designed with reinforcement distributed on each side equally. That means the total number of bars will always be a multiple of four (4). This may cause slightly conservative results in some cases. All major criteria for selecting longitudinal and transverse reinforcement as stipulated by AS 3600 have been taken care of in the column design of STAAD.

Example of Input Data for Column Design UNIT NEWTON MMS START CONCRETE DESIGN CODE AUSTRALIAN FYMAIN 415 ALL FC 35 ALL

Page 26: International Design Codes

Concrete Design Per AS 3600

Section 1A 1-6

CLEAR 25 MEMB 2 TO 6 MAXMAIN 40 MEMB 2 TO 6 DESIGN COLUMN 2 TO 6 END CONCRETE DESIGN

1A.8 Slab/Wall Design

To design a slab or wall, it must be modeled using finite elements. The command specifications are in accordance with Chapter 2, and Chapter 6 of the Technical Reference Manual. Elements are designed for the moments Mx and My. These moments are obtained from the element force output (see Section 3.8 of the Technical Reference Manual). The reinforcement required to resist Mx moment is denoted as longitudinal reinforcement and the reinforcement required to resist My moment is denoted as transverse reinforcement. The parameters FYMAIN, FC, MAXMAIN, MINMAIN and CLEAR listed in Table 1A.1 are relevant to slab design. Other parameters mentioned in Table 1A.1 are not applicable to slab design.

LONG.

TRANS.

X

Y

Z

M

MM

M x

y

x

y

Page 27: International Design Codes

Section 1A 1-7

Example of Input Data for Slab/Wall Design UNIT NEWTON MMS START CONCRETE DESIGN CODE AUSTRALIAN FYMAIN 415 ALL FC 25 ALL CLEAR 40 ALL DESIGN ELEMENT 15 TO 20 END CONCRETE DESIGN

Table 1A.1 Australian Concrete Design-AS 3600- Parameters

Parameter Name

Default Value Description

FYMAIN 415 N/mm2 Yield Stress for main reinforcing steel.

FYSEC 415 N/mm2 Yield Stress for secondary reinforcing steel.

FC 30 N/mm2 Concrete Yield Stress.

CLEAR 25 mm

40 mm

For beam members.

For column members

MINMAIN 10 mm Minimum main reinforcement bar size.

MAXMAIN 60 mm Maximum main reinforcement bar size.

MINSEC 8 mm Minimum secondary reinforcement bar size.

MAXSEC 12 mm Maximum secondary reinforcement bar size.

RATIO 4.0 Maximum percentage of longitudinal reinforcement in columns.

WIDTH ZD Width to be used for design. This value defaults to ZD as provided under MEMBER PROPERTIES.

DEPTH YD Total depth to be used for design. This value defaults to YD as provided under MEMBER PROPERTIES.

Page 28: International Design Codes

Concrete Design Per AS 3600

Section 1A 1-8

Table 1A.1 Australian Concrete Design-AS 3600- Parameters

Parameter Name

Default Value Description

TRACK 0.0 BEAM DESIGN:

For TRACK = 0.0, output consists of reinforcement details at START, MIDDLE and END.

For TRACK = 1.0, critical moments are printed in addition to TRACK 0.0 output.

For TRACK = 2.0, required steel for intermediate sections defined by NSECTION are printed in addition to TRACK 1.0 output.

COLUMN DESIGN:

With TRACK = 0.0, reinforcement details are printed.

REINF 0.0 Tied column. A value of 1.0 will mean spiral reinforcement.

Page 29: International Design Codes

1-9

Steel Design Per AS 4100 - 1998

Section 1B

1B.1 General

This section presents some general statements regarding the implementation of the specifications recommended by Standards Australia for structural steel design (AS 4100) in STAAD. The design philosophy and procedural logistics are based on the principles of elastic analysis and limit state method of design. Facilities are available for member selection as well as code checking. The design philosophy embodied in this specification is based on the concept of limit state design. Structures are designed and proportioned taking into consideration the limit states at which they would become unfit for their intended use. Two major categories of limit-state are recognized - ultimate and serviceability. The primary considerations in ultimate limit state design are strength and stability, while that in serviceability is deflection. Appropriate load and resistance factors are used so that a uniform reliability is achieved for all steel structures under various loading conditions and at the same time the chances of limits being surpassed are acceptably remote. In the STAAD implementation, members are proportioned to resist the design loads without exceeding the limit states of strength, stability and serviceability. Accordingly, the most economic section is selected on the basis of the least weight criteria as augmented by the designer in specification of allowable member depths, desired section type, or other such parameters. The code checking portion of the program checks whether code requirements for each selected section are met and identifies the governing criteria.

Page 30: International Design Codes

Steel Design Per AS 4100-1998

Section 1B 1-10 The following sections describe the salient features of the STAAD implementation of AS 4100. A detailed description of the design process along with its underlying concepts and assumptions is available in the specification document.

1B.2 Analysis Methodology

Elastic analysis method is used to obtain the forces and moments for design. Analysis is done for the primary and combination loading conditions provided by the user. The user is allowed complete flexibility in providing loading specifications and using appropriate load factors to create necessary loading situations. Depending upon the analysis requirements, regular stiffness analysis or P-Delta analysis may be specified. Dynamic analysis may also be performed and the results combined with static analysis results.

1B.3 Member Property Specifications

For specification of member properties, the steel section library available in STAAD may be used. The next section describes the syntax of commands used to assign properties from the built-in steel table. Member properties may also be specified using the User Table facility. For more information on these facilities, refer to the STAAD Technical Reference Manual.

1B.4 Built-in Steel Section Library

The following information is provided for use when the built-in steel tables are to be referenced for member property specification. These properties are stored in a database file. If called for, the properties are also used for member design. Since the shear areas are built into these tables, shear deformation is always considered during the analysis of these members. An example of the member property specification in an input file is provided at the end of this section.

Page 31: International Design Codes

Section 1B 1-11

A complete listing of the sections available in the built-in steel section library may be obtained by using the tools of the graphical user interface. Following are the descriptions of different types of sections. UB Shapes These shapes are designated in the following way.

20 TO 30 TA ST UB150X14.0 36 TO 46 TA ST UB180X16.1

UC Shapes The designation for the UC shapes is similar to that for the UB shapes.

25 TO 35 TA ST UC100X14.8 23 56 TA ST UC310X96.8

Welded Beams Welded Beams are designated in the following way.

25 TO 35 TA ST WB700X115 23 56 TA ST WB1200X455

Welded Columns Welded Columns are designated in the following way.

25 TO 35 TA ST WC400X114 23 56 TA ST WC400X303

Page 32: International Design Codes

Steel Design Per AS 4100-1998

Section 1B 1-12 Parallel Flange Channels Shown below is the syntax for assigning names of channel sections.

1 TO 5 TA ST PFC75 6 TO 10 TA ST PFC380

Double Channels Back to back double channels, with or without a spacing between them, are available. The letter D in front of the section name will specify a double channel.

11 TA D PFC230 17 TA D C230X75X25 SP 0.5

In the above set of commands, member 11 is a back to back double channel PFC230 with no spacing in between. Member 17 is a double channel PFC300 with a spacing of 0.5 length units between the channels. Angles Two types of specification may be used to describe an angle. The standard angle section is specified as follows:

16 20 TA ST A30X30X6

The above section signifies an angle with legs of length 30mm and a leg thickness of 6 mm. This specification may be used when the local Z axis corresponds to the z-z axis specified in Chapter 2. If the local Y axis corresponds to the z-z axis, type specification "RA" (reverse angle) may be used.

17 21 TA RA A150X150X16

Page 33: International Design Codes

Section 1B 1-13

Double Angles Short leg back to back or long leg back to back double angles can be specified by means of input of the words SD or LD, respectively, in front of the angle size. In case of an equal angle, either SD or LD will serve the purpose.

33 35 TA SD A65X50X5 SP 0.6 37 39 TA LD A75X50X6 43 TO 47 TA LD A100X75X10 SP 0.75

Tubes (Rectangular or Square Hollow Sections) Tubes can be assigned in 2 ways. In the first method, the designation for the tube is as shown below. This method is meant for tubes whose property name is available in the steel table. In these examples, members 1 to 5 consist of a 2X2X0.5 inch size tube section, and members 6 to 10 consist of 10X5X0.1875 inch size tube section. The name is obtained as 10 times the depth, 10 times the width, and 16 times the thickness.

1 TO 5 TA ST TUB20202.5 6 TO 10 TA ST TUB100503.0

In the second method, tubes are specified by their dimensions. For example,

6 TA ST TUBE DT 8.0 WT 6.0 TH 0.5

is a tube that has a height of 8 length units, width of 6 length units, and a wall thickness of 0.5 length units. Only code checking, no member selection, will be performed for TUBE sections specified in this latter manner.

Page 34: International Design Codes

Steel Design Per AS 4100-1998

Section 1B 1-14 Pipes (Circular Hollow Sections) Pipes can be assigned in 2 ways. In the first method, the designation for the pipe is as shown below. This method is meant for pipes whose property name is available in the steel table.

1 TO 5 TA ST PIP180X5 6 TO 10 TA ST PIP273X6.5

In the second method, pipe sections may be provided by specifying the word PIPE followed by the outside and inside diameters of the section. For example,

1 TO 9 TA ST PIPE OD 25.0 ID 20.0

specifies a pipe with outside diameter of 25 length units and inside diameter of 20 length units. Only code checking, no member selection, will be performed on pipes specified in this latter manner.

Sample File Containing Australian Shapes STAAD SPACE UNIT METER KN JOINT COORD 1 0 0 0 11 100 0 0 MEMB INCI 1 1 2 10 UNIT CM MEMBER PROPERTIES AUSTRALIAN * UB SHAPES 1 TA ST UB200X25.4 * UC SHAPES 2 TA ST UC250X89.5 * CHANNELS 3 TA ST PFC125

Page 35: International Design Codes

Section 1B 1-15

* DOUBLE CHANNELS 4 TA D PFC200 * ANGLES 5 TA ST A30X30X6 * REVERSE ANGLES 6 TA RA A150X150X16 * DOUBLE ANGLES - SHORT LEGS BACK TO BACK 7 TA SD A65X50X5 SP 0.6 * DOUBLE ANGLES - LONG LEGS BACK TO BACK 8 TA LD A100X75X10 SP 0.75 * TUBES (RECTANGULAR OR SQUARE HOLLOW SECTIONS) 9 TA ST TUBE DT 8.0 WT 6.0 TH 0.5 * PIPES (CIRCULAR HOLLOW SECTIONS) 10 TA ST PIPE OD 25.0 ID 20.0 PRINT MEMB PROP FINI

1B.5 Section Classification

The AS 4100 specification allows inelastic deformation of section elements. Thus, local buckling becomes an important criterion. Steel sections are classified as compact, non-compact or slender depending upon their local buckling characteristics. This classification is a function of the geometric properties of the section. The design procedures are different depending on the section class. STAAD determines the section classification for the standard shapes and user specified shapes. Design is performed for all three categories of section as mentioned above.

1B.6 Member Resistances

The member resistance is calculated in STAAD according to the procedures outlined in AS 4100. This depends on several factors such as members unsupported lengths, cross-sectional properties,

Page 36: International Design Codes

Steel Design Per AS 4100-1998

Section 1B 1-16 support condition and so on. The procedure adopted in STAAD for calculating the member resistance is explained here.

Axial Tension

The criteria governing the capacity of tension members is based on two limit states. Limit State of yielding of the gross section is intended to prevent excessive elongation of the member. The second limit state involves fracture at the section with the minimum effective net area. The user through the use of the parameter NSF (see Table 1B.1) may specify the net section area. STAAD calculates the tension capacity of a member based on these two limit states per Cl.7.1 and Cl.7.2 respectively of AS 4100. Parameters FYLD, FU, Kt and NSF are applicable for these calculations. Axial Compression

The compressive strength of members is determined based on Clause 6.1 of the code. It is taken as the lesser of nominal section capacity and nominal member capacity. Nominal section capacity is a function of form factor (Cl.6.2.2), net area of the cross section and yield stress of the material. The user through the use of the parameter NSC (see Table 1B.1) may specify the net section area. Note here, that this parameter is different from that corresponding to tension. The program automatically calculates form factor. Nominal member capacity is a function of nominal section capacity and member slenderness reduction factor (Cl.6.3.3). Here user is required to supply the value of αb (Cl.6.3.3). Table 1B.1 gives the default value of this parameter (named ALB). The effective length for the calculation of compressive strength may be provided through the use of the parameters KY, KZ, LY and LZ (see Table 1B.1). Bending

The allowable bending moment of members is determined as the lesser of nominal section capacity and nominal member capacity (ref. Cl.5.1). The nominal section moment capacity is the capacity to resist cross-section yielding or local buckling and is expressed

Page 37: International Design Codes

Section 1B 1-17

as the product of yield stress of material and effective section modulus (ref. Cl.5.2). The effective section modulus is a function of section type i.e. compact, non-compact or slender. The nominal member capacity depends on overall flexural-torsional buckling of the member (ref.Cl.5.3). Interaction of axial force and bending

The member strength for sections subjected to axial compression and uniaxial or biaxial bending is obtained through the use of interaction equations. Here also the adequacy of a member is examined against both section (ref. Cl.8.3.4) and member capacity (ref.Cl.8.4.5). If the summation of the left hand side of the equations, addressed by the above clauses, exceed 1.0 or the allowable value provided using the RATIO parameter (see Table 1B.1), the member is considered to have FAILed under the loading condition. Shear

Shear capacity of cross section is taken as the shear yield capacity. User may refer to Cl.5.11 in this context. Once the capacity is obtained, the ratio of the shear force acting on the cross section to the shear capacity of the section is calculated. If any of the ratios (for both local Y & Z-axes) exceed 1.0 or the allowable value provided using the RATIO parameter (see Table 1B.1), the section is considered to have failed under shear.

1B.7 Design Parameters

The design parameters outlined in Table 1B.1 may be used to control the design procedure. These parameters communicate design decisions from the engineer to the program and thus allow the engineer to control the design process to suit an application's specific needs.

Page 38: International Design Codes

Steel Design Per AS 4100-1998

Section 1B 1-18 The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements, some or all of these parameter values may be changed to exactly model the physical structure.

Table 1B.1- Australian Steel Design Parameters

Parameter Name

Default Value Description

KY 1.0 K value for general column flexural buckling about the local Y-axis. Used to calculate slenderness ratio.

KZ 1.0 K value for general column flexural buckling about the local Z-axis. Used to calculate slenderness ratio.

LY Member Length Length for general column flexural buckling about the local Y-axis. Used to calculate slenderness ratio.

LZ Member Length Length for general column flexural buckling about the local Z-axis. Used to calculate slenderness ratio.

FYLD 250.0 MPa Yield strength of steel.

FU 500.0 MPa Ultimate strength of steel.

NSF 1.0 Net section factor for tension members.

MAIN 0.0 0.0 = Check slenderness ratio against the limits.

1.0 = Suppress the slenderness ratio check.

2.0 = Check slenderness ratio only for column buckling, not for web (See Section 3B.6, Shear)

TRACK 0.0 0.0 = Report only minimum design results.

1.0 = Report design strengths also.

2.0 = Provide full details of design.

DMAX 45.0 in. Maximum allowable depth (Applicable for member selection)

DMIN 0.0 in. Minimum required depth (Applicable for member selection)

Page 39: International Design Codes

Section 1B 1-19

Table 1B.1- Australian Steel Design Parameters

Parameter Name

Default Value Description

RATIO 1.0 Permissible ratio of actual load effect to the design strength.

IST 1 Steel type - 1 - SR, 2 - HR, 3 - CF, 4 - LW,

5 - HW

PHI 0.9 Capacity reduction factor

NSC 1.0 Net section factor for compression members = An / Ag

(refer cl. 6.2.1)

ALM 1.0 Moment modification factor (refer cl. 5.6.1.1)

ALB 0.0 Member section constant (refer cl. 6.3.3)

KT 1.0 Correction factor for distribution of forces (refer cl. 7.2)

BEAM 0.0 0.0 = design only for end moments and those at locations specified by SECTION command.

1.0 = Perform design for moments at twelfth points along the beam.

UNT Member Length Unsupported length in bending compression of the top flange for calculating moment resistance.

UNB Member Length Unsupported length in bending compression of the bottom flange for calculating moment resistance.

DFF None (Mandatory for deflection

check)

“Deflection Length”/ Maxm. Allowable local deflection.

DJ1 Start Joint of member

Joint No. denoting start point for calculation of “deflection length”

DJ2 End Joint of member

Joint No. denoting end point for calculation of “deflection length”

Page 40: International Design Codes

Steel Design Per AS 4100-1998

Section 1B 1-20

1B.8 Code Checking

The purpose of code checking is to check whether the provided section properties of the members are adequate. The adequacy is checked as per AS 4100 requirements. Code checking is done using forces and moments at every twelfth point along the beam. The code checking output labels the members as PASSed or FAILed. In addition, the critical condition, governing load case, location (distance from the start joint) and magnitudes of the governing forces and moments are also printed. The extent of detail of the output can be controlled by using the TRACK parameter.

Example of commands for CODE CHECKING: UNIT NEWTON METER PARAMETER FYLD 330E6 MEMB 3 4 NSF 0.85 ALL KY 1.2 MEMB 3 4 RATIO 0.9 ALL CHECK CODE MEMB 3 4

Code checking cannot be performed on composite and prismatic sections.

1B.9 Member Selection

The member selection process basically involves determination of the least weight member that PASSes the code checking procedure based on the forces and moments of the most recent analysis. The section selected will be of the same type as that specified initially. For example, a member specified initially as a channel will have a

Page 41: International Design Codes

Section 1B 1-21

channel selected for it. Selection of members whose properties are originally provided from a user table will be limited to sections in the user table. Composite and prismatic sections cannot be selected.

Example of commands for MEMBER SELECTION: UNIT NEWTON METER PARAMETER FYLD 330E6 MEMB 3 4 NSF 0.85 ALL KY 1.2 MEMB 3 4 RATIO 0.9 ALL SELECT MEMB 3 4

1B.10 Tabulated Results of Steel Design

Results of code checking and member selection are presented in a tabular format. The term CRITICAL COND refers to the section of the AS 4100 specification which governs the design.

Page 42: International Design Codes

Steel Design Per AS 4100-1998

Section 1B 1-22

Page 43: International Design Codes

Section 2 British Codes

Page 44: International Design Codes

Kjahds;akh

Page 45: International Design Codes

2-1

Concrete Design Per BS8110

Section 2A

2A.1 Design Operations

It is strongly recommended that the user should perform new concrete design using the RC Designer Module. The following is provided to allow old STAAD files to be run. STAAD has the capability of performing design of concrete beams, columns and slabs according to BS8110. The 1997 revision of the code is currently implemented. Given the width and depth (or diameter for circular columns) of a section, STAAD will calculate the required reinforcement to resist the forces and moments.

2A.2 Design Parameters

The program contains a number of parameters which are needed to perform and control the design to BS8110. These parameters not only act as a method to input required data for code calculations but give the Engineer control over the actual design process. Default values of commonly used parameters for conventional design practice have been chosen as the basis. Table 2A.1 contains a complete list of available parameters with their default values.

Page 46: International Design Codes

Concrete Design Per BS8110

Section 2A 2-2

Table 2A.1 – British Concrete Design-BS8110-Parameters

Parameter Name

Default Value

Description

FYMAIN *460 N/mm2 Yield Stress for main reinforcement (For slabs, it is for reinforcement in both directions)

FYSEC *460N/mm2 Yield Stress for secondary reinforcement a. Applicable to shear bars in beams

FC * 30N/mm2 Concrete Yield Stress / cube strength

MINMAIN 8mm Minimum main reinforcement bar size Acceptable bar sizes: 6 8 10 12 16 20 25 32 40 50

MINSEC 8mm Minimum secondary bar size a. Applicable to shear reinforcement in beams

CLEAR * 20mm Clearance of reinforcement measured from concrete surface to closest bar perimeter.

MAXMAIN 50mm Maximum required reinforcement bar size Acceptable bars are per MINMAIN above.

SFACE *0.0 Face of support location at start of beam. (Only applicable for shear - use MEMBER OFFSET for bending )

EFACE *0.0 Face of support location at end of beam. (NOTE : Both SFACE & EFACE must be positive numbers.)

TRACK 0.0 0.0 = Critical Moment will not be printed with beam design report. Column design gives no detailed results.

1.0 = For beam gives min/max steel % and spacing. For columns gives a detailed table of output with additional moments calculated.

2.0 = Output of TRACK 1.0 List of design sag/hog moments and corresponding required steel area at each section of member

MMAG 1.0 Factor by which column design moments are magnified

NSECTION 10 Number of equally-spaced sections to be considered in finding critical moment for beam design. The upper limit is 20.

WIDTH *ZD Width of concrete member. This value default is as provided as ZD in MEMBER PROPERTIES.

DEPTH *YD Depth of concrete member. This value default is as provided as YD in MEMBER PROPERTIES.

Page 47: International Design Codes

Section 2A 2-3

Table 2A.1 – British Concrete Design-BS8110-Parameters

Parameter Name

Default Value

Description

BRACE 0.0 0.0 = Column braced in both directions. 1.0 = Column unbraced about local Z direction only 2.0 = Column unbraced about local Y direction only 3.0 = Column unbraced in both Y and Z directions

ELY 1.0 Member length factor about local Y direction for column design.

ELZ 1.0 Member length factor about local Z direction for column design.

SRA 0.0 0.0 = Orthogonal reinforcement layout without considering torsional moment Mxy -slabs only

-500 = Orthogonal reinforcement layout with Mxy used to calculate WOOD & ARMER moments for design.

A = Skew angle considered in WOOD & ARMER equations where A is the angle in degrees.

SERV 0.0 0.0 = No serviceability check performed. 1.0 = Perform serviceability check for beams as if they

were continuous. 2.0 = Perform serviceability check for beams as if they

were simply supported. 3.0 = Perform serviceability check for beams as if they

were cantilever beams. * Provided in current unit system

Page 48: International Design Codes

Concrete Design Per BS8110

Section 2A 2-4

2A.3 Slenderness Effects and Analysis Considerations

STAAD provides the user with two methods of accounting for the slenderness effects in the analysis and design of concrete members. The first method is equivalent to the procedure presented in BS8110 Part 1 1985 Section 3.8.2.2 In this section, the code recognizes that additional moments induced by deflection are present and states that these 'secondary' moments are accounted for by the design formula in Section 3.8.3. This is the method used in the design for concrete in STAAD. Alternatively STAAD houses a PDELTA ANALYSIS facility, which allows the effects of these second order moments to be considered in the analysis rather than the design. In a PDELTA analysis, after solving the joint displacements of the structure, the additional moments induced in the structure are calculated. These can be compared to those calculated using the formulation of BS8110.

2A.4 Member Dimensions

Concrete members that are to be designed by STAAD must have certain section properties input under the MEMBER PROPERTIES command. The following example demonstrates the required input:

UNIT MM MEMBER PROPERTIES *RECTANGULAR COLUMN 300mm WIDE X 450mm DEEP 1 3 TO 7 9 PRISM YD 450. ZD 300. *CIRCULAR COLUMN 300mm diameter 11 13 PR YD 300. * T-SECTION - FLANGE 1000.X 200.(YD-YB) * - STEM 250(THICK) X 350.(DEEP)

Page 49: International Design Codes

Section 2A 2-5

14 PRISM YD 550. ZD 1000. YB 350. ZB 250.

In the above input, the first set of members are rectangular (450mm depth x 300mm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with 300mm diameter. Note that area (AX) is not provided for these members. If shear area areas ( AY & AZ ) are to be considered in analysis, the user may provide them along with YD and ZD. Also note that if moments of inertias are not provided, the program will calculate them from YD and ZD. Finally a T section can be considered by using the third definition above.

2A.5 Beam Design

Beam design includes both flexure and shear. For both types of beam action, all active beam loadings are scanned to create moment and shear envelopes and locate the critical sections. The total number of sections considered is ten, unless that number is redefined with the NSECTION parameter. From the critical moment values, the required positive and negative bar pattern is developed with cut-off lengths calculated to include required development length.

Shear design as per BS8110 clause 3.4.5 has been followed and the procedure includes critical shear values plus torsional moments. From these values, stirrup sizes are calculated with proper spacing. The program will scan from each end of the member and provide a total of two shear regions at each, depending on the change of shear distribution along the beam. If torsion is present, the program will also consider the provisions of BS8110 - Part 2 -section 2.4. A table of shear and/or combined torsion is then provided with critical shear. Stirrups not bent up bars are assumed in the design. Table 2A.2 shows a sample output of an actual reinforcement pattern developed by STAAD. The following annotations apply to Table 2A.2

Page 50: International Design Codes

Concrete Design Per BS8110

Section 2A 2-6

1) LEVEL - Serial number of the bar centre which may contain one or more bar groups.

2) HEIGHT - Height of bar level from the soffit of the beam in relation to its local y axis.

3) BAR INFO - Reinforcement bar information specifying number of bars and their size.

4) FROM - Distance from the start of the beam to the start of the reinforcing bar.

5) TO - Distance from the start of the beam to the end of the reinforcing bar.

6) ANCHOR - States whether anchorage, either a hook or (STA,END) continuation, is needed at start (STA) or at the

end (END). TABLE 2A.2- ACTUAL DESIGN OUTPUT B E A M N O. 2 D E S I G N R E S U L T S - FLEXURE LEN - 3854. mm FY - 460. FC - 30. SIZE - 300. X 600. mm LEVEL HEIGHT BAR INFO FROM TO ANCHOR mm mm mm STA END 1 29. 6- 8 MM 0. 3854. YES YES CRITICAL POS MOMENT = 55.31 KN-M AT 1927. mm, LOAD 3 REQD STEEL = 261.mm2, ROW = 0.0014, ROWMX= 0.0400, ROWMN = 0.0013 MAX/MIN/ACTUAL BAR SPACING = 189./ 33./ 40. mm 2 565. 6- 8 MM 0. 3854. YES YES CRITICAL NEG MOMENT = 55.31 KN-M AT 1927. mm, LOAD 4 REQD STEEL = 261.mm2, ROW = 0.0014, ROWMX= 0.0400, ROWMN = 0.0013 MAX/MIN/ACTUAL BAR SPACING = 189./ 33./ 40. mm B E A M N O. 2 D E S I G N R E S U L T S - SHEAR PROVIDE SHEAR AND TORSIONAL LINKS AS FOLLOWS FROM - TO SHEAR TORSN LOAD LINK NO. SPACING mm C/C mm kN kNm S T SIZE S T S+T S T S+T END 1 1156 84.4 12 4 2 8 mm 3 5 9 335 199 116 2697 END 2 86.6 12 3 2 8 mm 3 5 9 335 199 116 EXTRA PERIPHERAL LONGITUDINAL TORSION STEEL: 402 mm2 EVENLY DISTRIBUTED * TORSIONAL RIGIDITY SHOULD CONFORM TO CL.2.4.3 - BS8110 *

Page 51: International Design Codes

Section 2A 2-7

2A.6 Column Design

Columns are designed for axial force and biaxial bending at the ends. All active loadings are tested to calculate reinforcement. The loading which produces maximum reinforcement is called the critical load and is displayed. The requirements of BS8110 Part 1 - section 3.8 are followed, with the user having control on the effective length in each direction by using the ELZ and ELY parameters as described in table 2A.1. Bracing conditions are controlled by using the BRACE parameter. The program will then decide whether or not the column is short or slender and whether it requires additional moment calculations. For biaxial bending, the recommendations of 3.8.4.5 of the code are considered. Column design is done for square, rectangular and circular sections. For rectangular and square sections, the reinforcement is always assumed to be arranged symmetrically. This causes slightly conservative results in certain cases. Table 2A.3 shows typical column design results. Using parameter TRACK 1.0, the detailed output below is obtained. TRACK 0.0 would merely give the bar configuration, required steel area and percentage, column size and critical load case.

Page 52: International Design Codes

Concrete Design Per BS8110

Section 2A 2-8

TABLE 2A.3 -COLUMN DESIGN OUTPUT C O L U M N No. 1 D E S I G N R E S U L T S FY - 460. FC -30. N/MM2 RECT SIZE - 300. X 600. MM, AREA OF STEEL REQUIRED = 875. SQ. MM. BAR CONFIGURATION REINF PCT. LOAD LOCATION 8 12 MM 0.486 3 EACH END (ARRANGE COLUMN REINFORCEMENTS SYMMETRICALLY) BRACED /SHORT in z E.L.z = 4500 mm ( 3.8.1.3 & 5 ) BRACED /SLENDER in y E.L.y = 4500 mm ( 3.8.1.3 & 5 ) END MOMS. MZ1 = 1 MZ2 = 25 MY1 = 53 MY2 = 40 SLENDERNESS MOMTS. KNM: MOMZ = 0 MOMY = 2 DESIGN LOADS KN METER: MOM. = 64 AXIAL LOAD = 84 DESIGNED CAP. KN METER: MOM. = 64 AXIAL CAP.= 187

2A.7 Slab Design

Slabs are designed to BS8110 specifications. To design a slab, it must first be modelled using finite elements. The command specifications are in accordance with section 5.51.3 of the Technical Reference Manual. A typical example of element design output is shown in Table 2A.4. The reinforcement required to resist the Mx moment is denoted as longitudinal reinforcement and the reinforcement required to resist the My moment is denoted as transverse reinforcement ( Fig. 4.1 ). The following parameters are those applicable to slab design: 1. FYMAIN - Yield stress for all reinforcing steel 2. FC - Concrete grade 3. CLEAR - Distance from the outer surface to the edge of

the bar. This is considered the same on both surfaces.

Page 53: International Design Codes

Section 2A 2-9

4. SRA - Parameter which denotes the angle of the required transverse reinforcement relative to the longitudinal reinforcement for the calculation of WOOD & ARMER design moments.

Other parameters, as shown in Table 2A.1 are not applicable. WOOD & ARMER equations. Ref: R H WOOD CONCRETE 1968 (FEBRUARY) If the default value of zero is used for the parameter SRA, the design will be based on the Mx and My moments which are the direct results of STAAD analysis. The SRA parameter (Set Reinforcement Angle) can be manipulated to introduce WOOD & ARMER moments into the design replacing the pure Mx, My moments. These new design moments allow the Mxy moment to be considered when designing the section. Orthogonal or skew reinforcement may be considered. SRA set to -500 will assume an orthogonal layout. If however a skew is to be considered, an angle is given in degrees measured anticlockwise (positive) from the element local x-axis to the reinforcement bar. The resulting Mx* and My* moments are calculated and shown in the design format. The design of the slab considers a fixed bar size of 16mm in both directions with the longitudinal bar being the layer closest to the slab exterior face. Typical output is as follows:

Page 54: International Design Codes

Concrete Design Per BS8110

Section 2A 2-10

TABLE 2A.4 -ELEMENT DESIGN OUTPUT ELEMENT DESIGN SUMMARY-BASED ON 16mm BARS MINIMUM AREAS ARE ACTUAL CODE MIN % REQUIREMENTS. PRACTICAL LAYOUTS ARE AS FOLLOWS: FY=460, 6No.16mm BARS AT 150mm C/C = 1206mm2/metre FY=250, 4No.16mm BARS AT 250mm C/C = 804mm2/metre ELEMENT LONG. REINF MOM-X /LOAD TRANS. REINF MOM-Y /LOAD (mm2/m) (kN-m/m) (mm2/m) (kN-m/m) WOOD & ARMER RESOLVED MOMENTS FOR ELEMENT: 13 UNITS: METER KN LOAD MX MY MXY MX* MY*/Ma* ANGLE 1 0.619 0.249 0.000 2.226 1.855 30.000 TOP 1 0.619 0.249 0.000 0.000 0.000 30.000 BOTT 3 0.437 0.184 -0.007 1.586 1.358 30.000 TOP 3 0.437 0.184 -0.007 0.000 0.000 30.000 BOTT

13 TOP : 195. 2.23 / 1 195. 1.86 / 1 BOTT : 195. 0.00 / 3 195. 0.00 / 3

2A.8 Shear Wall Design Purpose

Design of shear walls in accordance with BS 8110 has been added to the features of the program. Description The program implements the provisions of BS 8110 for the design of shear walls. It performs in-plane shear, compression, as well as in-plane and out-of-plane bending design of reinforcing. The shear wall is modeled by a single or a combination of Surface elements. The use of the Surface element enables the designer to treat the entire wall as one entity. It greatly simplifies the modeling of the wall and adds clarity to the analysis and design output. The results are presented in the context of the entire wall rather than individual finite elements thereby allowing users to quickly locate required information.

Page 55: International Design Codes

Section 2A 2-11

The program reports shear wall design results for each load case/combination for user specified number of sections given by SURFACE DIVISION (default value is 10) command. The shear wall is designed at these horizontal sections. The output includes the required horizontal and vertical distributed reinforcing, the concentrated (in-plane bending) reinforcing and the link required due to out-of-plane shear. General format: START SHEARWALL DESIGN CODE BRITISH FYMAIN f1 FC f2 HMIN f3 HMAX f4 VMIN f5 VMAX f6 EMIN f7 EMAX f8 LMIN f9 LMAX f10 CLEAR f11 TWOLAYERED f12 KSLENDER f13 DESIGN SHEARWALL LIST shearwall-list END

Page 56: International Design Codes

Concrete Design Per BS8110

Section 2A 2-12 The following table explains parameters used in the shear wall design command block above.

SHEAR WALL DESIGN PARAMETERS

Parameter Name

Default Value Description

FYMAIN 460 Mpa Yield strength of steel, in current units.

FC 30 Mpa Compressive strength of concrete, in current units.

HMIN 6 Minimum size of horizontal reinforcing bars (range 6 mm – 36 mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

HMAX 36 Maximum size of horizontal reinforcing bars (range 6 mm – 36 mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

VMIN 6 Minimum size of vertical reinforcing bars (range 6mm – 36mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

VMAX 36 Maximum size of vertical reinforcing bars (range 6mm – 36mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

EMIN 6 Minimum size of vertical reinforcing bars located in edge zones (range 6mm – 36mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

EMAX 36 Maximum size of vertical reinforcing bars located in edge zones (range 6mm – 36mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

LMIN 6 Minimum size of links (range 6mm – 16mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

LMAX 16 Maximum size of links (range 6mm – 16mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

Page 57: International Design Codes

Section 2A 2-13

SHEAR WALL DESIGN PARAMETERS

Parameter Name

Default Value Description

CLEAR 25 mm Clear concrete cover, in current units. TWOLAYERED 0 Reinforcement placement mode:

0 - single layer, each direction 1 - two layers, each direction

KSLENDER 1.5 Slenderness factor for finding effective height.

The following example starts from the definition of shear wall and ends at the shear wall design. Example

.

. SET DIVISION 12 SURFACE INCIDENCES 2 5 37 34 SUR 1 19 16 65 68 SUR 2 11 15 186 165 SUR 3 10 6 138 159 SUR 4 . . . SURFACE PROPERTY 1 TO 4 THI 18 SUPPORTS 1 7 14 20 PINNED 2 TO 5 GEN PIN 6 TO 10 GEN PIN 11 TO 15 GEN PIN 19 TO 16 GEN PIN . .

Page 58: International Design Codes

Concrete Design Per BS8110

Section 2A 2-14

. SURFACE CONSTANTS E 3150 POISSON 0.17 DENSITY 8.68e-005 ALPHA 5.5e-006 . . START SHEARWALL DES CODE BRITISH UNIT NEW MMS FC 25 FYMAIN 460 TWO 1 VMIN 12 HMIN 12 EMIN 12 DESIGN SHEA LIST 1 TO 4 END

Notes 1. Command SET DIVISION 12 indicates that the surface

boundary node-to-node segments will be subdivided into 12 fragments prior to finite element mesh generation.

2. Four surfaces are defined by the SURFACE INCIDENCES command.

3. The SUPPORTS command includes the new support generation routine. For instance, the line 2 TO 5 GEN PIN assigns pinned supports to all nodes between nodes 2 and 5. As the node-to-node distances were previously subdivided by the SET DIVISION 12 command, there will be an additional 11 nodes between nodes 2 and 5. As a result, all 13 nodes will be assigned pinned supports. Please note that the additional 11 nodes are not individually accessible to the user. They are created by the program to enable the finite element mesh generation and to allow application of boundary constraints.

Page 59: International Design Codes

Section 2A 2-15

4. Surface thickness and material constants are specified by the SURFACE PROPERTY and SURFACE CONSTANTS, respectively.

5. The shear wall design commands are listed between lines START SHEARWALL DES and END. The CODE command selects the design code that will be the basis for the design. For British code the parameter is BRTISH. The DESIGN SHEARWALL LIST command is followed by a list of previously defined Surface elements intended as shear walls and/or shear wall components.

Technical Overview The program implements provisions of section 3.9 of BS 8110:Part 1:1997 and relevant provisions as referenced therein, for all active load cases. The wall is designed as unbraced reinforced wall. The following steps are performed for each of the horizontal sections of the wall set using the SURFACE DIVISION command (see Description above). Checking of slenderness limit The slenderness checking is done for out-of-plane direction. For out-of-plane direction, the wall is assumed to be simply supported. Hence, the provisions of clause 3.9.3.2.2 and 3.9.4.2 are applicable. The default effective height is 1.5 times the clear height. User can change the effective height. The limit for slenderness is as per table 3.23 for unbraced wall, which is taken as 30. Design for in-plane bending (denoted by Mz in the shear wall force output) Walls are assumed to be cantilever beams fixed at their base and carrying loads to the foundation. Extreme compression fibre to centroid of tension (concentrated) reinforcement distance, d, is taken as 0.8 horizontal length of the wall. Flexural design of the wall is carried out in accordance with

Page 60: International Design Codes

Concrete Design Per BS8110

Section 2A 2-16

the provisions of clause no. 3.4.4. The flexural (concentrated vertical ) reinforcing is located at both ends (edges) of the length of the wall. The edge reinforcement is assumed to be distributed over a length of 0.2 times horizontal length on each side. This length is inclusive of the thickness of the wall. Minimum reinforcements are according to table 3.25. Design for in-plane shear (denoted by Fxy in the shear wall force output) Limit on the nominal shear strength, v is calculated as per clause no. 3.4.5.2. Nominal shear strength of concrete is computed as per table 3.8. The design shear stress is computed as per clause no. 3.4.5.12 taking into consideration the effect of axial load. The area of reinforcement is calculated and checked against the minimum area as per clause no. 3.12.7.4. Design for compression and out-of-plane vertical bending (denoted by Fy and My respectively in the shear wall force output) The wall panel is designed as simply supported (at top and bottom), axially loaded with out-of-plane uniform lateral load, with maximum moments and deflections occurring at mid-height. Design is done as per clause no. 3.8.4 for axially loaded column with uni-axial bending. The minimum reinforcement percentage is as per table 3.25. The maximum reinforcement percentage of vertical reinforcement is as per clause no. 3.12.6.3. Links if necessary are calculated as per the provisions of clause 3.12.7.5. Design for out-of-plane shear (denoted by Qy in the shear wall force output) The out-of-plane shear arises from out-of-plane loading. The design shear stress is calculated as per 3.4.5.2 and shear strength of concrete section is calculated as per table 3.8 considering vertical reinforcement as tension reinforcement.

Page 61: International Design Codes

Section 2A 2-17

Shear reinforcements in the form of links are computed as per table 3.7 and the provisions of clause 3.12.7.5. Design for out-of-plane horizontal bending (denoted by Mx in the shear wall force output) The horizontal reinforcement already calculated from in-plane shear are checked against the whole section subjected to out-of-plane bending and axial load. The axial load in this case is the in-plane shear. The section is again designed as axially loaded column under uni-axial bending as per the provisions of clause 3.8.4. Extra reinforcement in the form of horizontal bars, if necessary, is reported. Shear Wall Design With Opening

The Surface element has been enhanced to allow design of shear walls with rectangular openings. The automatic meshing algorithm has been improved to allow variable divisions along wall and opening(s) edges. Design and output are available for user selected locations. Description Shear walls modeled in STAAD.Pro may include an unlimited number of openings. Due to the presence of openings, the wall may comprise up with different wall panels.

1. Shear wall set-up Definition of a shear wall starts with a specification of the surface element perimeter nodes, meshing divisions along node-to-node segments, opening(s) corner coordinates, and meshing divisions of four edges of the opening(s).

SURFACE INCIDENCE n1, ..., ni SURFACE s DIVISION sd1, ..., sdj -

Page 62: International Design Codes

Concrete Design Per BS8110

Section 2A 2-18

RECOPENING x1 y1 z1 x2 y2 z2 x3 y3 z3 x4 y4 z4 DIVISION od1, ..., odk

where:

n1, ..., ni - node numbers on the perimeter of the shear wall, s - surface ordinal number, sd1, ..., sdj - number of divisions for each of the node-to-node

distance on the surface perimeter, x1 y1 z1 (...) - coordinates of the corners of the opening, od1, ..., odk - divisions along edges of the opening. Note:

If the sd1, ..., sdj or the od1, ..., odk list does not include all node-to-node segments, or if any of the numbers listed equals zero, then the corresponding division number is set to the default value (=10, or as previously input by the SET DIVISION command). Default locations for stress/force output, design, and design output are set as follows:

SURFACE DIVISION X xd SURFACE DIVISION Y yd

where: xd - number of divisions along X axis, yd - number of divisions along Y axis. Note: xd and yd represent default numbers of divisions for each edge of the surface where output is requested. The output is provided for sections located between division segments. For example, if the number of divisions = 2, then the output will be produced for only one section (at the center of the edge).

Page 63: International Design Codes

Section 2A 2-19

2. Stress/force output printing

Values of internal forces may be printed out for any user-defined section of the wall. The general format of the command is as follows:

PRINT SURFACE FORCE (ALONG ξ) (AT a) (BETWEEN d1, d2) LIST s1, ...,si where: ξ - local axis of the surface element (X or Y), a - distance along the � axis from start of the member to

the full cross-section of the wall, d1, d2 - coordinates in the direction orthogonal to �,

delineating a fragment of the full cross-section for which the output is desired.**

s1, ...,si - list of surfaces for output generation ** The range currently is taken in terms of local axis. If the local axis is directed away from the surface, the negative range is to be entered. Note: If command ALONG is omitted, direction Y (default) is assumed. If command AT is omitted, output is provided for all sections along the specified (or default) edge. Number of sections will be determined from the SURFACE DIVISION X or SURFACE DIVISION Y input values. If the BETWEEN command is omitted, the output is generated based on full cross-section width.

Page 64: International Design Codes

Concrete Design Per BS8110

Section 2A 2-20

3. Definition of wall panels Input syntax for panel definition is as follows:

START PANEL DEFINITION SURFACE i PANEL j ptype x1 y1 z1 x2 y2 z2 x3 y3 z3 x4 y4 z4 END PANEL DEFINITION

where: i - ordinal surface number, j - ordinal panel number, ptype - panel type, one of: WALL, COLUMN, BEAM x1 y1 z1 (...) - coordinates of the corners of the panel

4. Shear wall design The program implements different provisions of design of walls as per code BS 8110. General syntax of the design command is as follows:

START SHEARWALL DESIGN (...) DESIGN SHEARWALL (AT c) LIST s TRACK tr END SHEARWALL DESIGN

Parameter TRACK specifies how detailed the design output should be: 0 - indicates a basic set of results data (default), 1 - full design output will be generated.

Page 65: International Design Codes

Section 2A 2-21

Note: If the command AT is omitted, the design proceeds for all cross sections of the wall or panels, as applicable, defined by the SURFACE DIVISION X or SURFACE DIVISION Y input values. a. No panel definition.

Design is performed for the specified horizontal full cross-section, located at a distance c from the origin of the local coordinates system. If opening is found then reinforcement is provided along sides of openings. The area of horizontal and vertical bars provided along edges of openings is equal to that of the respective interrupted bars.

b. Panels have been defined.

Design is performed for all panels, for the cross-section located at a distance c from the start of the panel.

Page 66: International Design Codes

Concrete Design Per BS8110

Section 2A 2-22

Page 67: International Design Codes

2-23

Steel Design Per BS5950:2000

Section 2B

2B.1 General

The design philosophy embodied in BS5950:2000 is built around the concept of limit state design, used today in most modern steel design codes. Structures are designed and proportioned taking into consideration the limit states at which they become unfit for their intended use. Two major categories of limit state are recognized - serviceability and ultimate. The primary considerations in ultimate limit state design are strength and stability while that in serviceability limit state is deflection. Appropriate safety factors are used so that the chances of limits being surpassed are acceptably remote. In the STAAD implementation of BS5950:2000, members are proportioned to resist the design loads without exceeding the limit states of strength and stability. Accordingly, the most economic section is selected on the basis of the least weight criteria. This procedure is controlled by the designer in specification of allowable member depths, desired section type or other such parameters. The code checking portion of the program checks that code requirements for each selected section are met and identifies the governing criteria. The complete B.S.C. steel tables for both hot rolled and hollow sections are built into the program for use in specifying member properties as well as for the actual design process. See section 2B.4 for information regarding the referencing of these sections. In addition to universal beams, columns, joists, piles, channels, tees, composite sections, beams with cover plates, pipes, tubes and angles, there is a provision for user provided tables.

Page 68: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-24 STAAD.Pro 2006, has introduced the additional option to design tapered I shaped (wide flange) beams according to Annex G of BS5950. See section 2B.13 for a complete description. Single Angle Sections Angle sections are un-symmetrical and when using BS 5950:2000 table 25 we must consider four axes; two principal, u-u and v-v and two geometric, a-a and b-b. In a TRACK 2.0 design output, the ‘Buckling Calculations’ displays results for the ‘v-v’, ‘a-a’ and ‘b-b’ axes. The effective length for the v-v axis, Lvv, is taken as the LVV parameter or LY * KY, if not specified. The a-a and b-b axes are determined by which leg of the angle is fixed by the connection and should be specified using the LEG parameter, see section 2B6.6 for more information on the LEG parameter. The effective length in the a-a axis is taken as LY * KY and the effective length in the b-b axis as LZ * KZ. The following diagram shows the axes for angles which have been defined with either an ST or RA specification and is connected by its longer leg, i.e. a-a axis is parallel to the longer leg.

Local Z (u-u)

Local Y (v-v)

a

a

b

b

Local Z (v-v)

Local Y (u-u)

a

a

b

b

ST angle RA angle and USER table angles

Page 69: International Design Codes

Section 2B 2-25

2B.2 Analysis Methodology

Elastic analysis method is used to obtain the forces and moments for design. Analysis is done for the primary and combination loading conditions provided by the user. The user is allowed complete flexibility in providing loading specifications and using appropriate load factors to create necessary loading situations. Depending upon the analysis requirements, regular stiffness analysis or P-Delta analysis may be specified. Dynamic analysis may also be performed and the results combined with static analysis results.

2B.3 Member Property Specifications

For specification of member properties, the steel section library available in STAAD may be used. The next section describes the syntax of commands used to assign properties from the built-in steel table. Member properties may also be specified using the User Table facility. For more information on these facilities, refer to the STAAD Technical Reference Manual.

2B.4 Built-In Steel Section Library

The following information is provided for use when the built-in steel tables are to be referenced for member property specification. These properties are stored in a database file. If called for, the properties are also used for member design. Since the shear areas are built into these tables, shear deformation is always considered during the analysis of these members. Almost all BSI steel sections are available for input. A complete listing of the sections available in the built-in steel section library may be obtained by using the tools of the graphical user interface.

Page 70: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-26 Following are the descriptions of different types of sections available: Universal Beams, Columns And Piles All rolled universal beams, columns and pile sections are available. The following examples illustrate the designation scheme.

20 TO 30 TA ST UB305X165X54 33 36 TA ST UC356X406X287 100 102 106 TA ST UP305X305X186

Rolled Steel Joists

Joist sections may be specified as they are listed in BSI-80 with the weight omitted. In those cases where two joists have the same specifications but different weights, the lighter section should be specified with an "A" at the end.

10 TO 20 TA ST JO152X127 1 2 TA ST JO127X114A

Channel Sections

All rolled steel channel sections from the BSI table have been incorporated in STAAD. The designation is similar to that of the joists. The same designation scheme as in BSI tables may be used with the weight omitted.

10 TO 15 TA ST CH305X102 55 57 59 61 TA ST CH178X76

Page 71: International Design Codes

Section 2B 2-27

Double Channels

Back to back double channels, with or without spacing between them, are available. The letter "D" in front of the section name will specify a double channel, e.g. D CH102X51, D CH203X89 etc.

51 52 53 TA D CH152X89 70 TO 80 TA D CH305X102 SP 5. (specifies a double channel with a spacing of 5 length units)

Tee Sections

Tee sections are not input by their actual designations, but instead by referring to the universal beam shapes from which they are cut. For example,

54 55 56 TA T UB254X102X22 (tee cut from UB254X102X22)

Angles

All equal and unequal angles are available for analysis. Two types of specifications may be used to describe an angle section, either a standard, ST specification or reversed angle, RA specification. Note, however, that only angles specified with an RA specification can be designed. The standard angle section is specified as follows:

15 20 25 TA ST UA200X150X18

Page 72: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-28

This specification may be used when the local STAAD z-axis corresponds to the V-V axis specified in the steel tables. If the local STAAD y-axis corresponds to the V-V axis in the tables, type specification "RA" (reverse angle) may be used.

35 TO 45 TA RA UA200X150X18

Double Angles

Short leg back to back or long leg back to back double angles can be specified by inputting the word SD or LD, respectively, in front of the angle size. In case of an equal angle, either LD or SD will serve the purpose. For example,

14 TO 20 TA LD UA200X200X16 SP 1.5 23 27 TA SD UA80X60X6 "SP" denotes spacing between the individual angle sections.

Note that if the section is defined from a Double Angle User Table, then the section properties must be defined with an 11th value which defines the radius of gyration about an individual sections’ principal v-v axis (See Technical Reference Manual, 5.19 User Steel Table Specification) Pipes (Circular Hollow Sections)

To designate circular hollow sections from BSI tables, use PIP followed by the numerical value of diameter and thickness of the section in mm omitting the decimal section of the value provided for diameter. The following example will illustrate the designation.

10 15 TA ST PIP213.2 (specifies a 21.3 mm dia. pipe with 3.2 mm wall thickness)

Page 73: International Design Codes

Section 2B 2-29

Circular hollow sections may also be provided by specifying the outside and inside diameters of the section. For example,

1 TO 9 TA ST PIPE OD 25.0 ID 20.0 (specifies a pipe with outside dia. of 25 and inside dia. of 20 in current length units)

Only code checking and no member selection will be performed if this type of specification is used. Tubes (Rectangular or Square Hollow Sections)

Designation of tubes from the BSI steel table is illustrated below:

TUB 400 200 12.5

Square/Rectangular shape

Height (mm)

Thickness (mm)

Width (mm)

Example: 15 TO 25 TA ST TUB160808.0

Tubes, like pipes, can also be input by their dimensions (Height, Width and Thickness) and not by any table designations.

6 TA ST TUBE DT 8.0 WT 6.0 TH 0.5 (a tube that has a height of 8, a width of 6, and a wall thickness of 0.5 length units)

Note that only code checking and no member selection is performed for TUBE sections specified this way.

Page 74: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-30

2B.5 Member Capacities

The basic measure of capacity of a beam is taken as the plastic moment of the section. This is a significant departure from the standard practice followed in BS449, in which the limiting condition was attainment of yield stress at the extreme fibres of a given section. With the introduction of the plastic moment as the basic measure of capacity, careful consideration must be given to the influence of local buckling on moment capacity. To assist this, sections are classified as either Class 1, plastic, Class 2, compact, Class 3, semi-compact or Class 4, slender, which governs the decision whether to use the plastic or the elastic moment capacity. The section classification is a function of the geometric properties of the section. STAAD is capable of determining the section classification for both hot rolled and built up sections. In addition, for slender sections, BS5950 recommends the use of a 'stress reduction factor' to reduce the design strength. This factor is again a function of the geometry of the section and is automatically determined by STAAD for use in the design process. Axial Tension

In members with axial tension, the tensile load must not exceed the tension capacity of the member. The tension capacity of the member is calculated on the basis of the effective area as outlined in Section 4.6 of the code. STAAD calculates the tension capacity of a given member per this procedure, based on a user supplied net section factor (NSF-a default value of 1.0 is present but may be altered by changing the input value - see Table 2B.1 ), proceeding with member selection or code check accordingly. BS5950 does not have any slenderness limitations for tension members. Compression

Compression members must be designed so that the compression resistance of the member is greater than the axial compressive load. Compression resistance is determined according to the compressive strength, which is a function of the slenderness of the

Page 75: International Design Codes

Section 2B 2-31

gross section, the appropriate design strength and the relevant strut characteristics. Strut characteristics take into account the considerable influence residual rolling and welding stresses have on column behaviour. Based on data collected from extensive research, it has been determined that sections such as tubes with low residual stresses and Universal Beams and Columns are of intermediate performance. It has been found that I-shaped sections are less sensitive to imperfections when constrained to fail about an axis parallel to the flanges. These research observations are incorporated in BS5950 through the use of four strut curves together with a selection of tables to indicate which curve to use for a particular case. Compression strength for a particular section is calculated in STAAD according to the procedure outlined in Annex C of BS5950 where compression strength is seen to be a function of the appropriate Robertson constant ( representing Strut Curve) corresponding Perry factor, limiting slenderness of the member and appropriate design strength. A departure from BS5950:1990, generally compression members are no longer required to be checked for slenderness limitations, however, this option can be included by specifying a MAIN parameter. Note, a slenderness limit of 50 is still applied on double angles checked as battened struts as per clause 4.7.9. Axially Loaded Members With Moments

In the case of axially loaded members with moments, the moment capacity of the member must be calculated about both principal axes and all axial forces must be taken into account. If the section is plastic or compact, plastic moment capacities will constitute the basic moment capacities subject to an elastic limitation. The purpose of this elastic limitation is to prevent plasticity at working load. For semi-compact or slender sections, the elastic moment is used. For plastic or compact sections with high shear loads, the plastic modulus has to be reduced to accommodate the shear loads. The STAAD implementation of BS5950 incorporates the procedure outlined in section 4.2.5 and 4.2.6 to calculate the appropriate moment capacities of the section.

Page 76: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-32 For members with axial tension and moment, the interaction formula as outlined in section 4.8.2 is applied based on effective tension capacity. For members with axial compression and moment, two principal interaction formulae must be satisfied – Cross Section Capacity check (4.8.3.2) and the Member Buckling Resistance check (4.8.3.3 ). Three types of approach for the member buckling resistance check have been outlined in BS5950:2000 - the simplified approach (4.8.3.3.1), the more exact approach (4.8.3.3.2) and Annex I1 for stocky members. As noted in the code, in cases where neither the major axis nor the minor axis moment approaches zero, the more exact approach may be more conservative than the simplified approach. It has been found, however, that this is not always the case and STAAD therefore performs both checks, comparing the results in order that the more appropriate criteria can be used. Additionally the equivalent moment factors, mx my and myx, can be specified by the user or calculated by the program. Members subject to biaxial moments in the absence of both tensile and compressive axial forces are checked using the appropriate method described above with all axial forces set to zero. STAAD also carries out cross checks for compression only, which for compact/plastic sections may be more critical. If this is the case, COMPRESSION will be the critical condition reported despite the presence of moments. Shear Load

A member subjected to shear is considered adequate if the shear capacity of the section is greater than the shear load on the member. Shear capacity is calculated in STAAD using the procedure outlined in section 4.2.3, also 4.4.5 and Annex H3 if appropriate, considering the appropriate shear area for the section specified.

Page 77: International Design Codes

Section 2B 2-33

Lateral Torsional Buckling

Since plastic moment capacity is the basic moment capacity used in BS5950, members are likely to experience relatively large deflections. This effect, coupled with lateral torsional buckling, may result in severe serviceability limit state. Hence, lateral torsional buckling must be considered carefully. The procedure to check for lateral torsional buckling as outlined in section 4.3 has been incorporated in the STAAD implementation of BS5950. According to this procedure, for a member subjected to moments about the major axis, the 'equivalent uniform moment' on the section must be less than the lateral torsional buckling resistance moment. For calculation of the buckling resistance moment, the procedure outlined in Annex B.2 has been implemented for all sections with the exception of angles. In Annex B.2., the resistance moment is given as a function of the elastic critical moment, Perry coefficient, and limiting equivalent slenderness, which are calculated within the program; and the equivalent moment factor, mLT, which is determined as a function of the loading configuration and the nature of the load (stabilizing, destabilizing, etc). R. H. S Sections - Additional Provisions Rectangular Hollow sections are treated in accordance with S.C.I. recommendations in cases when the plastic axis is in the flange. In such cases, the following expressions are used to calculate the reduced plastic moduli:

Srx = (A*A/4(B-t))(1-n) [ 2D(B-t)/A + n-1 ]

for n>= 2t(D-2t)/A Sry = (A*A/4(D-t))(1-n) [ 2B(D-t)/A + n-1 ]

for n>= 2t(B-2t)/A

Page 78: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-34

2B.6 Design Parameters

Available design parameters to be used in conjunction with BS5950 are listed in table 2B.1 along with their default values. The following items should be noted with respect to their use. 1. (PY – Steel Design Strength )

The design parameter PY should only be used when a uniform design strength for an entire structure or a portion thereof is required. Otherwise the value of PY will be set according to the stipulations of BS5950 table 9 in which the design strength is seen as a function of cross sectional thickness for a particular steel grade (SGR parameter) and particular element considered. Generally speaking this option is not required and the program should be allowed to ascertain the appropriate value.

2. (UNL, LY and LZ - Relevant Effective Length) The values supplied for UNL, LY and LZ should be real numbers greater than zero in current units of length. They are supplied along with or instead of UNF, KY and KZ (which are factors, not lengths) to define lateral torsional buckling and compression effective lengths respectively. Please note that both UNL or UNF and LY or KY values are required even though they are often the same values. The former relates to compression flange restraint for lateral torsional buckling while the latter is the unrestrained buckling length for compression checks.

3. (TRACK - Control of Output Formats )

When the TRACK parameter is set to 0.0, 1.0 or 2.0, member capacities will be printed in design related output (code check or member selection) in kilonewtons per square metre. TRACK 4.0 causes the design to carry out a deflection check, usually with a different load list to the main code check. The members that are to be checked must have the parameters, DFF, DJ1 and DJ2 set.

Page 79: International Design Codes

Section 2B 2-35

An example of each TRACK setting follows:-

TRACK 0.0 OUTPUT STAAD CODE CHECKING - (BSI ) --------------------------- ****************************** ALL UNITS ARE - KNS METR (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ================================================================= 1 ST UB686X254X170 PASS BS-4.8.3.2 0.036 3 86.72 C 0.00 -22.02 4.50 --------------------------------- TRACK 1.0 OUTPUT STAAD CODE CHECKING - (BSI ) --------------------------- ****************************** ALL UNITS ARE - KNS METR (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ================================================================= 1 ST UB686X254X170 PASS BS-4.8.3.2 0.036 3 86.72 C 0.00 -22.02 4.50 CALCULATED CAPACITIES FOR MEMB 1 UNIT - kN,m SECTION CLASS 4 MCZ= 1141.9 MCY= 120.4 PC= 3451.5 PT= 5739.9 MB= 1084.1 PV= 1597.5 BUCKLING CO-EFFICIENTS m AND n : m = 1.000 n = 1.000 PZ= 5739.90 FX/PZ = 0.02 MRZ= 1141.9 MRY= 120.4

Page 80: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-36 TRACK 2.0 OUTPUT STAAD.Pro CODE CHECKING - (BSI )

--------------------------- ***************************

ALL UNITS ARE - KN METE (UNLESS OTHERWISE NOTED)

MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/

FX MY MZ LOCATION

===================================================================

1 ST UB533X210X92 PASS BS-4.3.6 0.902 100

0.00 0.00 585.41 0.00

===================================================================

MATERIAL DATA

Grade of steel = S 275

Modulus of elasticity = 205 kN/mm2

Design Strength (py) = 275 N/mm2

SECTION PROPERTIES (units - cm)

Member Length = 325.00

Gross Area = 117.00 Net Area = 117.00

Major axis Minor axis

Moment of inertia : 55229.996 2389.000

Plastic modulus : 2360.000 356.000

Elastic modulus : 2072.031 228.285

Shear Area : 58.771 53.843

DESIGN DATA (units - kN,m) BS5950-1/2000

Section Class : PLASTIC

Major axis Minor axis

Moment Capacity : 649.0 94.2

Reduced Moment Capacity : 649.0 97.9

Shear Capacity : 969.7 888.4

BUCKLING CALCULATIONS (units - kN,m)

(axis nomenclature as per design code)

LTB Moment Capacity (kNm) and LTB Length (m): 649.00, 0.001

LTB Coefficients & Associated Moments (kNm):

Page 81: International Design Codes

Section 2B 2-37

mLT = 1.00 : mx = 1.00 : my = 1.00 : myx = 1.00

Mlt = 585.41 : Mx = 585.41 : My = 0.00 : My = 0.00

CRITICAL LOADS FOR EACH CLAUSE CHECK (units- kN,m):

CLAUSE RATIO LOAD FX VY VZ MZ MY

BS-4.2.3-(Y) 0.329 100 - 292.3 - - -

BS-4.3.6 0.902 100 - 292.3 - 585.4 -

BS-4.8.3.2 0.814 100 0.0 68.0 0.0 585.4 0.0

BS-4.8.3.3.1 1.027 100 0.0 - - 585.4 0.0

BS-4.8.3.3.2 0.902 100 0.0 - - 585.4 0.0

Annex I.1 0.902 100 0.0 - - 585.4 0.0

Torsion and deflections have not been considered in the design.

_________________________ 4. (MX, MY, MYX and MLT – Equivalent Moment Factors)

The values for the equivalent moment factors can either be specified directly by the user as a positive value between 0.4 and 1.0 for MX, MY and MYX and 0.44 and 1.0 for MLT. The program can be used to calculate the values for the equivalent moment factors by defining the design member with a GROUP command (see the Technical Reference Manual section 5.16 Listing of Members/Elements/Joints by Specification of GROUPS). The nodes along the beam can then be defined as the location of restraint points with J settings. Additionally for the MLT parameter, the joint can be defined as having the upper flange restrained (positive local Y) with the a U setting or the lower flange restrained (negative local Y) with a L setting.

Page 82: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-38 For example, consider a series of 5 beam elements as a single continuous member as shown below:

To sign, the beam needs to be defined as a gro :

EFINITION

_MainBeam 11 2 38 12 3

Noteclick

‘ Therefore, this 5 beam member has 6 joints such that:-

JJoint 2 = Node 1 J

enable the steel deup, called MainBeam

START GROUP DMEMBER

END GROUP DEFINITION

that this can be done in the GUI by selecting the beams and ing on the menu option:

Tools | Create New Group…’

oint 1 = Node 3

oint 3 = Node 33

Page 83: International Design Codes

Section 2B 2-39

Joint 4 = Node 14 JJ

C and MYX

it has nt

een restrained at

is:-

For the lateral flexural buckling, local X axis:- MYX _ MainBeam J1 J6

b. Consider MLT Say that this member has been restrained at its’ ends against lateral torsional buckling and the top flange has been restrained at node number 33 (joint 3) and only the lower flange at node number 7, (joint 5). Hence:- MLT _MainBeam J1 T3 L5 J6 To split the beam into two buckling lengths for Ly at joint 14:- MY _groupname J1 J4 J6

oint 5 = Node 7 oint 6 = Node 2

a. onsider MX, MY

Say that this member has been restrained in its’ major axis (local Y) only at the ends. In the minor axis (local Z) been restrained at the ends and also at node number 33 (joi3). For local flexural buckling, it has only bits ends. Hence:- For the major axis, local Y axis:- MX _MainBeam J1 J6 For the minor axis, local Z axMY _ MainBeam J1 J3 J6

Page 84: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-40 5. (LEG - Table 25 BS5950 for Fastener Control)

The slenderness of single and double angle, channel and tee sections are specified in BS 5950 table 25 depending on the connection provided at the end of the member. To define the appropriate connection, a LEG parameter should be assigned to the member. The following table indicates the value of the LEG parameter required to match the BS5950 connection definition:- Clause LEG

short leg 1.0 (a) - 2 bolts long leg 3.0 short leg 0.0

4.7.10.2 Single Angle (b) - 1 bolt

long leg 2.0

short leg 3.0 (a) - 2 bolts long leg 7.0 short leg 2.0 (b) - 1 bolt long leg 6.0 long leg 1.0 (c) - 2 bolts short leg 5.0 long leg 0.0

4.7.10.3 Double Angle

(d) - 1 bolt short leg 4.0

(a) - 2 or more rows of bolts 1.0 4.7.10.4

Channels (b) - 1 row of bolts 0.0

(a) - 2 or more rows of bolts 1.0 4.7.10.5 Tee Sections (b) - 1 row of bolts 0.0

For single angles, the slenderness is calculated for the geometric axes, a-a and b-b as well as the weak v-v axis. The effective lengths of the geometric axes are defined as:- La = KY * KY Lb = KZ * LZ

Page 85: International Design Codes

Section 2B 2-41

The slenderness calculated for the v-v axis is then used to calculate the compression strength pc for the weaker principal axis (z-z for ST angles or y-y for RA specified angles). The maximum slenderness of the a-a and b-b axes is used to calculate the compression strength pc for the stronger principal axis. Alternatively for single angles where the connection is not known or Table 25 is not appropriate, by setting the LEG parameter to 10, slenderness is calculated for the two principal axes y-y and z-z only. The LVV parameter is not used. For double angles, the LVV parameter is available to comply with note 5 in table 25. In addition, if using double angles from user tables, (Technical Reference Manual section 5.19) an eleventh value, rvv, should be supplied at the end of the ten existing values corresponding to the radius of gyration of the single angle making up the pair.

6. (SWAY – Sway Loadcase)

This parameter is used to specify a load case that is to be treated as a sway load case in the context of clause 4.8.3.3.4. This load case would be set up to represent the “kampMs” mentioned in this clause and the steel design module would add the forces from this load case to the forces of the other load case it is designed for. Note that the load case specified with this parameter will not be designed as a separate load case. The following is the correct syntax for the parameter:- SWAY

(load case number)

ALL MEMBER (member list) _(group name)

e.g.

SWAY 5 MEM 1 to 10 SWAY 6 _MainBeams

Page 86: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-42

Table 2B.1 - British Steel Design – BS5950:2000 - Parameters

Parameter Name

Default Value

Description

CODE BS5950 Design Code to follow. See section 5.47.1 of the Technical Reference Manual.

SGR 0.0 Steel Grade per BS4360 0.0 = Grade S 275 1.0 = Grade S 355 2.0 = Grade S 460 3.0 = As per GB 1591 – 16 Mn

AD Depth at end/2

Distance between the reference axis and the axis of restraint. See G.2.3

PY * Set according to steel grade

(SGR)

Design strength of steel

KY 1.0 K factor value in local y - axis. Usually, this is the minor axis.

KZ 1.0 K factor value in local z - axis. Usually, this is the major axis.

LY * Member Length

Length in local y - axis (current units) to calculate (KY)(LY)/Ryy slenderness ratio.

LZ * Member Length

Length in local z - axis (current units) to calculate (KZ)(LZ)/Rzz slenderness ratio.

UNF 1.0 Factor applied to unsupported length for Lateral Torsional Buckling effective length per section 4.3.7.5 of BS5950.

UNL * Member Length

Unsupported Length for calculating Lateral Torsional Buckling resistance moment section 4.3.7.5 of BS5950.

NSF 1.0 Net section factor for tension members.

SBLT 0.0 Identify Section type for section classification 0.0 = Rolled Section 1.0 = Built up Section 2.0 = Cold formed section

MAIN 0.0 Slenderness limit for members with compression forces, effective length/ radius of gyration, for a given axis:- 0.0 = Slenderness not performed. 1.0 = Main structural member (180) 2.0 = Secondary member. (250) 3.0 = Bracing etc (350)

Page 87: International Design Codes

Section 2B 2-43

Table 2B.1 - British Steel Design – BS5950:2000 - Parameters

Parameter Name

Default Value

Description

TRACK 0.0 0.0 = Suppress all member capacity info. 1.0 = Print all member capacities. 2.0 = Print detailed design sheet. 4.0 = Deflection Check (separate check to main select /

check code)

BEAM 3.0 0.0 = Design only for end moments or those locations specified by the SECTION command.

1.0 = Calculate forces and moments at 12th points along the member. Establish the location where Mz is the maximum. Use the forces and moments at that location. Clause checks at one location.

2.0 = Same as BEAM = 1.0 but additional checks are carried out for each end.

3.0 = Calculate moments at 12th points along the member. Clause checks at each location including the ends of the member.

LEG 0.0 Valid range from 0 – 7 and 10. See section 2B.6.5 for details. The values correspond to table 25 of BS5950 for fastener conditions.

LVV * Maximum of Lyy and Lzz

(Lyy is a term used

by BS5950)

Used in conjunction with LEG for Lvv as per BS5950 table 25 for double angles, note 5.

CB 1.0 1.0 = BS5950 per clause B.2.5 (continuous) to calculate Mb.

2.0 = To calculate Mbs (simple) as per Clause 4.7.7 as opposed to Mb.

DFF None (Mandatory

for deflection check,

TRACK 4.0)

"Deflection Length" / Maxm. allowable local deflection

DJ1 Start Joint of member

Joint No. denoting starting point for calculation of "Deflection Length" (See Note 1)

DJ2 End Joint of member

Joint No. denoting end point for calculation of "Deflection Length" (See Note 1)

Page 88: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-44

Table 2B.1 - British Steel Design – BS5950:2000 - Parameters

Parameter Name

Default Value

Description

ESTIFF 0.0 Clauses 4.8.3.3.1 and 4.8.3.3.2 0.0 = Fail ratio uses MIN of 4.8.3.3.1, 4.8.3.3.2. and

Annex I1 checks. 1.0 = Fail ratio uses MAX of 4.8.3.3.1, 4.8.3.3.2. and

Annex I1 checks. WELD 1.0 closed

2.0 open

Weld Type, see AISC steel design 1.0 = Closed sections. Welding on one side only (except

for webs of wide flange and tee sections) 2.0 = Open sections. Welding on both sides (except

pipes and tubes) TB 0.0 0.0 = Elastic stress analysis

1.0 = Plastic stress analysis PNL * 0.0 Transverse stiffener spacing (‘a’ in Annex H1)

0.0 = Infinity Any other value used in the calculations.

SAME** 0.0 Controls the sections to try during a SELECT process.

0.0 = Try every section of the same type as original 1.0 = Try only those sections with a similar name as

original, e.g. if the original is an HEA 100, then only HEA sections will be selected, even if there are HEM’s in the same table.

MX 1.0 Equivalent moment factor for major axis flexural buckling as defined in clause 4.8.3.3.4

MY 1.0 Equivalent moment factor for minor axis flexural buckling as defined in clause 4.8.3.3.4

MYX 1.0 Equivalent moment factor for minor axis lateral flexural buckling as defined in clause 4.8.3.3.4

MLT 1.0 Equivalent moment factor for lateral torsional buckling as defined in clause 4.8.3.3.4

SWAY none Specifies a load case number to provide the sway loading forces in clause 4.8.3.3.4 (See additional notes)

DMAX * 100.0cm Maximum allowable depth

Page 89: International Design Codes

Section 2B 2-45

Table 2B.1 British Steel Design – BS5950:2000 Parameters

Parameter Name

Default Value

Description

DMIN * 0.0cm Minimum allowable depth

RATIO 1.0 Permissible ratio of the actual capacities.

* current units must be considered.

**For angles, if the original section is an equal angle, then the selected section will be an equal angle and vice versa for unequal angles. (note there was an NT parameter in STAAD.Pro 2005 build 1003 which is now automatically calculated during the design as it is load case dependant)

NOTES: 1) "Deflection Length" is defined as the length that is used for

calculation of local deflections within a member. It may be noted that for most cases the "Deflection Length" will be equal to the length of the member. However, in some situations, the "Deflection Length" may be different. For example, refer to the figure below where a beam has been modeled using four joints and three members. Note that the "Deflection Length" for all three members will be equal to the total length of the beam in this case. The parameters DJ1 and DJ2 should be used to model this situation. Also the straight line joining DJ1 and DJ2 is used as the reference line from which local deflections are measured. Thus, for all three members here, DJ1 should be "1" and DJ2 should be "4".

D = Maximum local deflection for members1, 2 and 3.

D

1

2 3

4

1

2 3

EXAMPLE : PARAMETERS DFF 300. ALL DJ1 1 ALL DJ2 4 ALL

2) If DJ1 and DJ2 are not used, "Deflection Length" will default

to the member length and local deflections will be measured from original member line.

Page 90: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-46 3) The above parameters may be used in conjunction with other

available parameters for steel design.

2B.7 Design Operations

STAAD contains a broad set of facilities for the design of structural members as individual components of an analysed structure. The member design facilities provide the user with the ability to carry out a number of different design operations. These facilities may be used selectively in accordance with the requirements of the design problem. The operations to perform a design are:

• Specify the load cases to be considered in the design; the

default is all load cases. • Specify design parameter values, if different from the default

values. • Specify whether to perform code checking or member selection

along with the list of members.

These operations may be repeated by the user any number of times depending upon the design requirements.

2B.8 Code Checking

The purpose of code checking is to ascertain whether the provided section properties of the members are adequate. The adequacy is checked as per BS5950. Code checking is done using the forces and moments at specific sections of the members. If no sections are specified, the program uses the start and end forces for code checking. When code checking is selected, the program calculates and prints whether the members have passed or failed the checks; the critical condition of BS5950 code (like any of the BS5950 specifications for compression, tension, shear, etc.); the value of the ratio of the

Page 91: International Design Codes

Section 2B 2-47

critical condition (overstressed for value more than 1.0 or any other specified RATIO value); the governing load case, and the location (distance from the start of the member of forces in the member where the critical condition occurs). Code checking can be done with any type of steel section listed in Section 2B.4 of the STAAD Technical Reference Manual or any of the user defined sections in section 5.19 with two exceptions; GENERAL and ISECTION. In BS5950, these will not be considered for design along with PRISMATIC sections, which are also not acceptable.

2B.9 Member Selection

STAAD is capable of performing design operations on specified members. Once an analysis has been performed, the program can select the most economical section, i.e. the lightest section, which fulfills the code requirements for the specified member. The section selected will be of the same type section as originally designated for the member being designed. Member selection can also be constrained by the parameters DMAX and DMIN, which limits the maximum and minimum depth of the members.

Member selection can be performed with all the types of steel sections with the same limitations as defined in section 2B.8 - CODE CHECKING. Selection of members, whose properties are originally input from a user created table, will be limited to sections in the user table. Member selection cannot be performed on members whose section properties are input as prismatic or as above limitations for code checking.

Page 92: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-48

2B.10 Tabulated Results of Steel Design

For code checking or member selection, the program produces the results in a tabulated fashion. The items in the output table are explained as follows: a) MEMBER refers to the member number for which the

design is performed. b) TABLE refers to steel section name, which has been

checked against the steel code or has been selected.

c) RESULTS prints whether the member has PASSED or FAILED. If the RESULT is FAIL, there will be an asterisk (*) mark on front of the member.

d) CRITICAL COND refers to the section of the BS5950 code

which governs the design. e) RATIO prints the ratio of the actual stresses to

allowable stresses for the critical condition. Normally a value of 1.0 or less will mean the member has passed.

f) LOADING provides the load case number, which

governed the design. g) FX, MY, and MZ provide the axial force, moment in local Y-

axis and the moment in local z-axis respectively. Although STAAD does consider all the member forces and moments (except torsion) to perform design, only FX, MY and MZ are printed since they are the ones which are of interest, in most cases.

Page 93: International Design Codes

Section 2B 2-49

h) LOCATION specifies the actual distance from the start of the member to the section where design forces govern.

i) TRACK If the parameter TRACK is set to 1.0, the

program will block out part of the table and will print the allowable bending capacities in compression (MCY & MCZ) and reduced moment capacities (MRY & MRZ), allowable axial capacity in compression (PC) and tension (PT) and shear capacity (PV). TRACK 2.0 will produce the design results as shown in section 2B.9.

2B.11 Plate Girders

Sections will be considered for the Plate Girder checks (BS 5950 Section 4.4) if d/t > 70 ε for ‘rolled sections’ or d/t >62 ε for ‘welded sections’. The parameter SBLT should be used to identify sections as rolled or welded; see the parameter list for more information.

If the plate girder has intermediate stiffeners, the spacing is set with the PNL parameter. These are then used to check against the code clauses ‘4.4.3.2 - Minimum web thickness for serviceability’ and ‘4.4.3.3 - Minimum web thickness to avoid compression flange buckling’. The following printout is then included if a TRACK 2.0 output is selected:-

Shear Buckling check is required: Vb = 1070 kN : qw = 118 N/mm2

d = 900 mm : t = 10 mm : a = 200 mm : pyf = 275 N/mm2

BS-4.4.3.2 status = PASS : BS-4.4.3.3 status = PASS

The section is then checked for shear buckling resistance using clause ‘4.4.5.2 - Simplified method’ and the result is included in the ratio checks.

Page 94: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-50

2B.12 Composite Sections

Sections that have been defined as acting compositely with a concrete flange either from a standard database section using the CM option, or from a modified user WIDE FLANGE database with the additional composite parameters, cannot be designed with BS5950:2000.

2B.13 Design of Tapered Beams

Design Procedure Sections will be checked as tapered members provided that are defined either as a Tapered I section, e.g.

UNIT CM

MEMBER PROPERTY

1 TO 5 TAPERED 100 2.5 75 25 4 25 4

or from a USER table, e.g.

START USER TABLE

TABLE 1

UNIT CM

ISECTION

1000mm_TAPER

100 2.5 75 25 4 25 4 0 0 0

750mm_TAPER

75 2.5 50 25 4 25 4 0 0 0

END

Page 95: International Design Codes

Section 2B 2-51

The user must specify the effective length of unrestrained compression flange using the parameter UNL. The program compares the resistance of members with the applied load effects, in accordance with BS 5950-1:2000. Code checking is carried out for locations specified by the user via the SECTION command or the BEAM parameter. The results are presented in a form of a PASS/FAIL identifier and a RATIO of load effect to resistance for each member checked. The user may choose the degree of detail in the output data by setting the TRACK parameter. The beam is designed is designed as other wide flange beams apart from the Lateral Torsional Buckling check which is replaced by the Annex G.2.2. check. Design Equations A beam defined with tapered properties as defined above will be checked as a regular wide flange (e.g. UB or UC), except that the following is used in place of clause 4.3.6, the lateral torsional buckling check. Check Moment for Taper Members as per clause G.2.2

The following criterion is checked at each defined check position in the length of the member defined by the BEAM parameter. )/1( ccbixi PFMM −≤ Where F is the longitudinal compression at the check location; c

Mbi is the buckling resistance moment Mb from 4.3.6 for an equivalent slenderness λTB, see G.2.4.2, based on the appropriate modulus S, Seff, Z or Zeff of the cross-section at the point i considered;

Mxi is the moment about the major axis acting at the point i considered;

Page 96: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-52 Pc is the compression resistance from 4.7.4 for a slenderness

λTC, see G.2.3, based on the properties of the minimum depth of cross-section within the segment length Ly.

G.2.3 Slenderness λTC

λTC = yλ In which:

5.0

22

2

)/(05.0)/2(1)/2(1

⎥⎦

⎤⎢⎣

⎡++

+=

xhaha

ys

s

λ

λ = Ly/ry

Where a is the distance between the reference axis and the axis of

restraint, hs is the distance between the shear centers of the flanges; Ly is the length of the segment; ry is the radius of gyration for buckling about the minor axis; x torsional index

G.2.4.2 Equivalent slenderness λTB for Taper members λTB = cntνtλ In which for a two-flange haunch:

5.0

22 )/(05.0)/2(

1⎣t

/4⎥⎦

⎤⎢⎡

++=

xhaha

s

s

λν

here c is the taper factor, see G.2.5;

W

Page 97: International Design Codes

Section 2B 2-53

G.2.5 Taper factor For an I-section with D ≥ 1.2B and x ≥ 20 the taper factor c should be obtained as follows:

c = 1 + 3/2

min

max 19

3⎟⎟⎠

⎞⎜⎜⎝

⎛−

− DD

x

Dmax is the maximum depth of cross-section within the length Ly, see Figure G.3;

Dmin is the minimum depth of cross-section within the length Ly, see Figure G.3;

x is the torsional index of the minimum depth cross-section, see 4.3.6.8

Otherwise c is taken as 1.0

Page 98: International Design Codes

Steel Design Per BS5950:2000

Section 2B 2-54

Page 99: International Design Codes

2-55

Steel Design Per BS5950:1990

Section 2B1

2B1.1 General

This code has been withdrawn by the British Standards, but has been retained in STAAD.Pro for comparative purposes only. The design philosophy embodied in BS5950 is built around the concept of limit state design, used today in most modern steel design codes. Structures are designed and proportioned taking into consideration the limit states at which they become unfit for their intended use. Two major categories of limit state are recognized - serviceability and ultimate. The primary considerations in ultimate limit state design are strength and stability while that in serviceability limit state is deflection. Appropriate safety factors are used so that the chances of limits being surpassed are acceptably remote. In the STAAD implementation of BS5950, members are proportioned to resist the design loads without exceeding the limit states of strength and stability. Accordingly, the most economic section is selected on the basis of the least weight criteria. This procedure is controlled by the designer in specification of allowable member depths, desired section type or other such parameters. The code checking portion of the program checks that code requirements for each selected section are met and identifies the governing criteria. The complete B.S.C. steel tables for both hot rolled and hollow sections are built into the program for use in specifying member properties as well as for the actual design process. See section 2B.4 for information regarding the referencing of these sections. In addition to universal beams, columns, joists, piles, channels,

Page 100: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-56 tees, composite sections, beams with cover plates, pipes, tubes and angles, there is a provision for user provided tables.

2B1.2 Analysis Methodology

Elastic analysis method is used to obtain the forces and moments for design. Analysis is done for the primary and combination loading conditions provided by the user. The user is allowed complete flexibility in providing loading specifications and using appropriate load factors to create necessary loading situations. Depending upon the analysis requirements, regular stiffness analysis or P-Delta analysis may be specified. Dynamic analysis may also be performed and the results combined with static analysis results.

2B1.3 Member Property Specifications

For specification of member properties, the steel section library available in STAAD may be used. The next section describes the syntax of commands used to assign properties from the built-in steel table. Members properties may also be specified using the User Table facility. For more information on these facilities, refer to the STAAD Technical Reference Manual.

2B1.4 Built-In Steel Section Library

The following information is provided for use when the built-in steel tables are to be referenced for member property specification. These properties are stored in a database file. If called for, the properties are also used for member design. Since the shear areas are built into these tables, shear deformation is always considered during the analysis of these members. Almost all BSI steel sections are available for input. A complete listing of the sections available in the built-in steel section library may be obtained by using the tools of the graphical user interface.

Page 101: International Design Codes

Section 2B1 2-57

Following are the descriptions of different types of sections available: Universal Beams, Columns And Piles All rolled universal beams, columns and pile sections are available. The following examples illustrate the designation scheme.

20 TO 30 TA ST UB305X165X54 33 36 TA ST UC356X406X287 100 102 106 TA ST UP305X305X186

Rolled Steel Joists

Joist sections may be specified as they are listed in BSI-80 with the weight omitted. In those cases where two joists have the same specifications but different weights, the lighter section should be specified with an "A" at the end.

10 TO 20 TA ST JO152X127 1 2 TA ST JO127X114A

Channel Sections All rolled steel channel sections from the BSI table have been incorporated in STAAD. The designation is similar to that of the joists. The same designation scheme as in BSI tables may be used with the weight omitted.

10 TO 15 TA ST CH305X102 55 57 59 61 TA ST CH178X76

Double Channels

Back to back double channels, with or without spacing between them, are available. The letter "D" in front of the section name will specify a double channel, e.g. D CH102X51, D CH203X89 etc.

Page 102: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-58

51 52 53 TA D CH152X89 70 TO 80 TA D CH305X102 SP 5. (specifies a double channel with a spacing of 5 length units)

Tee Sections

Tee sections are not input by their actual designations, but instead by referring to the universal beam shapes from which they are cut. For example,

54 55 56 TA T UB254X102X22 (tee cut from UB254X102X22)

Angles

All equal and unequal angles are available for input. Two types of specifications may be used to describe an angle. The standard angle section is specified as follows:

15 20 25 TA ST UA200X150X18

This specification may be used when the local STAAD z-axis corresponds to the V-V axis specified in the steel tables. If the local STAAD y-axis corresponds to the V-V axis in the tables, type specification "RA" (reverse angle) may be used.

35 TO 45 TA RA UA200X150X18

Double Angles

Short leg back to back or long leg back to back double angles can be specified by inputting the word SD or LD, respectively, in front of the angle size. In case of an equal angle, either LD or SD will serve the purpose. For example,

Page 103: International Design Codes

Section 2B1 2-59

14 TO 20 TA LD UA200X200X16 SP 1.5 23 27 TA SD UA80X60X6 "SP" denotes spacing between the individual angle sections.

Pipes (Circular Hollow Sections)

To designate circular hollow sections from BSI tables, use PIP followed by the numerical value of diameter and thickness of the section in mm omitting the decimal section of the value provided for diameter. The following example will illustrate the designation.

10 15 TA ST PIP213.2 (specifies a 21.3 mm dia. pipe with 3.2 mm wall thickness)

Circular hollow sections may also be provided by specifying the outside and inside diameters of the section. For example,

1 TO 9 TA ST PIPE OD 25.0 ID 20.0 (specifies a pipe with outside dia. of 25 and inside dia. of 20 in current length units)

Only code checking and no member selection will be performed if this type of specification is used. Tubes (Rectangular or Square Hollow Sections)

Designation of tubes from the BSI steel table is illustrated below:

TUB 400 200 12.5

Tube symbol

Height (mm)

Thickness (mm)

Width (mm)

Page 104: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-60

Example: 15 TO 25 TA ST TUB160808.0

Tubes, like pipes, can also be input by their dimensions (Height, Width and Thickness) and not by any table designations.

6 TA ST TUBE DT 8.0 WT 6.0 TH 0.5 is a tube that has a height of 8, a width of 6, and a wall thickness of 0.5 length units.

Note that only code checking and no member selection is performed for TUBE sections specified this way.

2B1.5 Member Capacities

The basic measure of capacity of a beam is taken as the plastic moment of the section. This is a significant departure from the standard practice followed in BS449, in which the limiting condition was attainment of yield stress at the extreme fibres of a given section. With the introduction of the plastic moment as the basic measure of capacity, careful consideration must be given to the influence of local buckling on moment capacity. To assist this, sections are classified as either plastic, compact, semi-compact or slender, which governs the decision whether to use the plastic or the elastic moment capacity. The section classification is a function of the geometric properties of the section. STAAD is capable of determining the section classification for both hot rolled and built up sections. In addition, for slender sections, BS5950 recommends the use of a 'stress reduction factor' to reduce the design strength. This factor is again a function of the geometry of the section and is automatically determined by STAAD for use in the design process. Axial Tension

In members with axial tension, the tensile load must not exceed the tension capacity of the member. The tension capacity of the member is calculated on the basis of the effective area as outlined

Page 105: International Design Codes

Section 2B1 2-61

in Section 4.6 of the code. STAAD calculates the tension capacity of a given member per this procedure, based on a user supplied net section factor (NSF-a default value of 1.0 is present but may be altered by changing the input value - see Table 2B.1 ), proceeding with member selection or code check accordingly. BS5950 does not have any slenderness limitations for tension members. Compression

Compression members must be designed so that the compression resistance of the member is greater than the axial compressive load. Compression resistance is determined according to the compressive strength which is a function of the slenderness of the gross section, the appropriate design strength and the relevant strut characteristics. Strut characteristics take into account the considerable influence residual rolling and welding stresses have on column behaviour. Based on data collected from extensive research, it has been determined that sections such as tubes with low residual stresses and Universal Beams and Columns are of intermediate performance. It has been found that I-shaped sections are less sensitive to imperfections when constrained to fail about an axis parallel to the flanges. These research observations are incorporated in BS5950 through the use of four strut curves together with a selection of tables to indicate which curve to use for a particular case. Compression strength for a particular section is calculated in STAAD according to the procedure outlined in Appendix C of BS5950 where compression strength is seen to be a function of the appropriate Robertson constant ( representing Strut Curve) corresponding Perry factor, limiting slenderness of the member and appropriate design strength. In addition to the compression resistance criteria, compression members are required to satisfy slenderness limitations which are a function of the nature of the use of the member ( main load resisting component, bracing member etc). In both the member selection and the code checking process, STAAD immediately does a slenderness check on appropriate members before continuing with the other procedures for determining the adequacy of a given member.

Page 106: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-62 Axially Loaded Members With Moments

In the case of axially loaded members with moments, the moment capacity of the member must be calculated about both axes and all axial forces must be taken into account. If the section is plastic or compact, plastic moment capacities will constitute the basic moment capacities subject to an elastic limitation. The purpose of this elastic limitation is to prevent plasticity at working load. For semi-compact or slender sections, the elastic moment is used. For plastic or compact sections with high shear loads, the plastic modulus has to be reduced to accommodate the shear loads. The STAAD implementation of BS5950 incorporates the procedure outlined in section 4.2.5 and 4.2.6 to calculate the appropriate moment capacities of the section. For members with axial tension and moment, the interaction formula as outlined in section 4.8.2 is applied based on effective tension capacity. For members with axial compression and moment, two principal interaction formulae must be satisfied - local capacity check (4.8.3.2) and overall buckling check (section 4.8.3.3 ). Two types of approach for the overall buckling check have been outlined in BS5950 - the simplified approach and the more exact approach. As noted in the code, in cases where neither the major axis nor the minor axis moment approaches zero, the more exact approach may be more conservative than the simplified approach. It has been found, however, that this is not always the case and STAAD therefore performs both checks, comparing the results in order that the more appropriate criteria be used. Members subject to biaxial moments in the absence of both tensile and compressive axial forces are checked using the appropriate method described above with all axial forces set to zero. STAAD also carries out cross checks for compression only, which for compact/plastic sections may be more critical. If this is the case, COMPRESSION will be the critical condition reported despite the presence of moments.

Page 107: International Design Codes

Section 2B1 2-63

Shear Load

A member subjected to shear is considered adequate if the shear capacity of the section is greater than the shear load on the member. Shear capacity is calculated in STAAD using the procedure outlined in section 4.2.3 and considering the appropriate shear area for the section specified. Lateral Torsional Buckling

Since plastic moment capacity is the basic moment capacity used in BS5950, members are likely to experience relatively large deflections. This effect, coupled with lateral torsional buckling, may result in severe serviceability limit state. Hence, lateral torsional buckling must be considered carefully. The procedure to check for lateral torsional buckling as outlined in section 4.3 has been incorporated in the STAAD implementation of BS5950. According to this procedure, for a member subjected to moments about the major axis, the 'equivalent uniform moment' on the section must be less than the lateral torsional buckling resistance moment. For calculation of the buckling resistance moment, the procedure outlined in Appendix B.2 has been implemented for all sections with the exception of angles. In Appendix B.2., the resistance moment is given as a function of the elastic critical moment, Perry coefficient, and limiting equivalent slenderness, which are calculated within the program; and the equivalent moment factor, m, and slenderness correction factor, n, which are determined as a function of the loading configuration and the nature of the load ( stabilizing, destabilizing, etc ). The user is allowed to control these values through the parameters CMM & CMN. If CMM is set to -1, the program automatically calculates the coefficient 'm'. Similarly parameter CMN may be used for the calculation of coefficient 'n'. BS5950 recommends the use of tables 15 & 16 for the calculation of coefficient 'n'. The parameter CMN may be set to -1 or -2 to instruct the program to obtain coefficient 'n' from table 15 or 16 respectively. If a positive value is provided for either CMN or CMM, the program will use this value directly in calculations. The default value for each of

Page 108: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-64 these parameters is 1.0 as shown in table 2B.1 of this document. It may be noted that BS5950 recommends the use of either 'm' or 'n' in lateral torsional buckling calculations. If both 'm' and 'n' are set to values less than 1 in error, the program will always reset CMN to 1 and over-ride the provided value. The following table illustrates the use of parameters 'm' and 'n'. PARAMETER VALUE STAAD ACTION CMM ANY POSITIVE Direct use of this value in VALUE calculations. -1 Program calculates 'm' per BS5950 -2 Calculate ‘m’ for both axes CMN ANY POSITIVE Direct use of this value in VALUE calculations. -1 Program calculates 'n' per BS5950 - Table 15 -2 Program calculates 'n' per BS5950 - Table 16 IMPORTANT NOTE: Note that if negative value options are chosen, lateral restraints should be modelled by nodes and the section command incorporated to find Mo. Failure to use the SECTION 0.5 command will cause the program to reset CMN to 1.0 and over-ride any value that may have been provided. In requesting 'n' to be calculated by the program by using a negative CMN value, the member properties must be British ( or British combined with user table sections). If other profiles such as European are being used then 'n' values are reset conservatively to 1.0 by the program. In the case of angles, section 4.3.8 of the code is followed.

R. H. S Sections - Additional Provisions Rectangular Hollow sections are treated in accordance with S.C.I. recommendations in cases when the plastic axis is in the flange. In such cases, the following expressions are used to calculate the reduced plastic moduli:

Page 109: International Design Codes

Section 2B1 2-65

Srx = (A*A/4(B-t))(1-n) [ 2D(B-t)/A + n-1 ] for n>= 2t(D-2t)/A

Sry = (A*A/4(D-t))(1-n) [ 2B(D-t)/A + n-1 ]

for n>= 2t(B-2t)/A

2B1.6 Design Parameters

Available design parameters to be used in conjunction with BS5950 are listed in table 2B.1 along with their default values. The following items should be noted with respect to their use. 1. (PY - STEEL DESIGN STRENGTH )

The design parameter PY should only be used when a uniform design strength for an entire structure or a portion thereof is required. Otherwise the value of PY will be set according to the stipulations of BS5950 table 7 in which the design strength is seen as a function of cross sectional thickness for a particular steel grade and particular element considered. Generally speaking this option is not required and the program should be allowed to ascertain the appropriate value.

2. (UNL, LY and LZ - relevant EFFECTIVE LENGTHS) The values supplied for UNL, LY and LZ should be real numbers greater than zero in current units of length. They are supplied along with or instead of UNF, KY KZ ( which are factors, not lengths) to define lateral torsional buckling and compression effective lengths respectively. Please note that both UNL or UNF and LY or KY values are required even though they are often the same values. The former relates to compression flange restraint for lateral torsional buckling while the latter is the unrestrained buckling length for compression checks.

3. (CMN and CMM - Lateral torsional buckling coefficients)

As per section 2B.7 of this manual CMM and CMN should not both be used in a given design. In such a case the program will reset CMN to 1.0

Page 110: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-66 4. (TRACK - control of output formats )

When the TRACK parameter is set to 1.0 or 2.0, member capacities will be printed in design related output ( code check or member selection ) in kilonewtons per square metre. An example of each follows.

TRACK 0.0 OUTPUT STAAD CODE CHECKING - (BSI ) --------------------------- ****************************** ALL UNITS ARE - KNS METR (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ================================================================= 1 ST UB686X254X170 PASS BS-4.8.3.2 0.036 3 86.72 C 0.00 -22.02 4.50 ---------------------------------

Page 111: International Design Codes

Section 2B1 2-67

TRACK 1.0 OUTPUT STAAD CODE CHECKING - (BSI ) --------------------------- ****************************** ALL UNITS ARE - KNS METR (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ================================================================= 1 ST UB686X254X170 PASS BS-4.8.3.2 0.036 3 86.72 C 0.00 -22.02 4.50 CALCULATED CAPACITIES FOR MEMB 1 UNIT - kN,m SECTION CLASS 4 MCZ= 1141.9 MCY= 120.4 PC= 3451.5 PT= 5739.9 MB= 1084.1 PV= 1597.5 BUCKLING CO-EFFICIENTS m AND n : m = 1.000 n = 1.000 PZ= 5739.90 FX/PZ = 0.02 MRZ= 1141.9 MRY= 120.4 TRACK 2.0 OUTPUT STAAD CODE CHECKING - (BSI ) --------------------------- ****************************** ALL UNITS ARE - KNS METR (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ================================================================= 1 ST UB686X254X170 PASS BS-4.8.3.2 0.036 3 86.72 C 0.00 -22.02 4.50 ================================================================= MATERIAL DATA

Grade of steel = 43 Modulus of elasticity = 205 kN/mm2 Design Strength (py) = 265 N/mm2 Reduced = 232N/mm2

SECTION PROPERTIES (units - cm)

Member Length = 450.00 Gross Area = 216.60 Net Area = 216.60

z-axis y-axis

Moment of inertia : 170147.000 6621.000 Plastic modulus : 5624.000 810.000 Elastic modulus : 4911.156 517.670 Shear Area : 109.122 100.470 Radius of gyration : 28.027 5.529 Effective Length : 450.000 450.000

Page 112: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-68 DESIGN DATA (units - kN,m) BS5950/1990

Section Class : SLENDER Squash Load : 5739.90 Axial force/Squash load : 0.015

z-axis y-axis

Slenderness ratio (KL/r) : 16.1 81.4 Compression Capacity : 5036.2 3451.5 Tension Capacity : 5739.9 5739.9 Moment Capacity : 1141.9 120.4 Reduced Moment Capacity : 1141.9 120.4 Shear Capacity : 1561.5 1597.5

BUCKLING CALCULATIONS (units - kN,m) Lateral Torsional Buckling Moment (MB = 1084.1) co-efficients m & n : m =1.00 n =1.00, Effective Length =4.500 CRITICAL LOADS FOR EACH CLAUSE CHECK (units- kN,m): CLAUSE RATIO LOAD FX VY VZ MZ MY BS-4.7 (C) 0.025 3 86.7 3.2 0.0 -22.0 0.0 BS-4.8.3.2 0.036 3 86.7 3.2 0.0 -22.0 0.0 BS-4.8.3.3.1 0.047 1 83.3 7.4 0.0 -27.6 0.0 BS-4.8.3.3.2 0.026 1 83.3 7.4 0.0 -27.6 0.0 BS-4.2.3-(Y) 0.005 1 83.3 7.4 0.0 -27.6 0.0 BS-4.3 (LTB) 0.020 4 -86.7 3.2 0.0 22.0 0.0 Torsion and deflections have not been considered in the design 5. ( LEG - table 24/28 BS5950 for fastner control )

The LEG parameter follows the requirements of BS5950 table 28. This table concerns the fastner restraint conditions for angles, double angles, tee sections and channels for slenderness. The following values are available:

Clause 4.7.10.2 (a) Single Angle, short leg 1.0

(b) Single Angle, short leg 0.0 (a) Single Angle, long leg 3.0 (b) Single Angle, long leg 2.0

Page 113: International Design Codes

Section 2B1 2-69

Clause 4.7.10.3 (a) Double angle, short leg 3.0 (b) Double angle, short leg 2.0

(c) Double angle, long leg 1.0 (d) Double angle, long leg 0.0 (a) Double angle, long leg 7.0 (b) Double angle, long leg 6.0 (c) Double angle, short leg 5.0 (d) Double angle, short leg 4.0

Clause 4.7.10.4 (a) Channels, 2 or more rows 1.0 (b) Channels, 1 row 0.0

Clause 4.7.10.5 (a) Tee sections, 2 or more rows 1.0 (b) Tee sections, 1 row 0.0

When defining member properties for single angles, the spec (manual ref: 5.20.1) should be provided as RA and not ST. See fig 1.6 of the Technical Reference Manual. Table 28 may be by-passed in favour of table 24 by using:

10 = Table 24 for equal angles or long legs of unequal angles

11 = Table 24 for short legs of unequal angles For single angles, LY and KY parameters should be provided relative to the raa axis while LZ and KZ are related to rbb. Lvv will be considered as the minimum of the KY*LY and KZ*LZ values. For double angles, the LVV parameter is available to comply with note 5 table 28. In addition, if using double angles from user tables, (Technical Reference Manual section 5.19) an eleventh value, rvv, should be supplied at the end of the ten existing values corresponding to the radius of gyration of the single angle making up the pair.

Page 114: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-70

Table 2B1.1 - British Steel Design – BS5950:1990 - Parameters

Parameter Name

Default Value Description

KY 1.0 K factor value in local y - axis. Usually, this is the minor axis.

KZ 1.0 K factor value in local z - axis. Usually, this is the major axis.

LY * Member Length

Length in local y - axis (current units) to calculate (KY)(LY)/Ryy slenderness ratio.

LZ * Member Length

Length in local z - axis (current units) to calculate (KZ)(LZ)/Rzz slenderness ratio.

UNF 1.0 Factor applied to unsupported length for Lateral Torsional Buckling effective length per section 4.3.7.5 of BS5950.

UNL * Member Length

Unsupported Length for calculating Lateral Torsional Buckling resistance moment section 4.3.7.5 of BS5950.

PY * Set according to steel grade

(SGR)

Design Strength of steel

NSF 1.0 Net section factor for tension members.

SGR 0.0 Steel Grade per BS4360 0.0 = Grade 43 1.0 = Grade 50 2.0 = Grade 55 3.0 = As per GB 1591 – 16 Mn

SBLT 0.0 0.0 = Rolled Section 1.0 = Built up Section

MAIN 1.0 As per BS5950 4.7.3 1.0 = Main structural member (180) 2.0 = Secondary member. (250) 3.0 = Bracing etc (350)

CMM ! 1.0 Coefficient m for lateral torsional buckling. (see section 2B.5)

CMN ! 1.0 Coefficient n for lateral torsional buckling. (see section 2B.5)

TRACK 0.0 0.0 = Suppress all member capacity info. 1.0 = Print all member capacities. 2.0 = Print detailed design sheet. 4.0 = Deflection Check (separate check to main select / check code)

Page 115: International Design Codes

Section 2B1 2-71

Table 2B1.1 - British Steel Design – BS5950:1990 - Parameters

Parameter Name

Default Value Description

DMAX * 100.0cm Maximum allowable depth

DMIN * 0.0cm Minimum allowable depth

RATIO 1.0 Permissible ratio of the actual capacities.

BEAM 0.0 0.0 = Design only for end moments or those locations specified by the SECTION command.

1.0 = Calculate moments at 12th points along the member and use the maximum Mz value for design. Clause checks at one location

2.0 = Same as BEAM = 1.0 but additional checks are carried out for each end.

3.0 = Calculate moments at 12th points along the member. Clause checks at each location including the ends of the member.

CODE BS5950 Design Code to follow. See section 5.47.1 of the Technical Reference Manual.

LEG 0.0 Values range from 0 - 12. See section 2B.6.5 for details. The values correspond to table 24/28 of BS5950 for fastner conditions.

LVV * Maximum of Lyy and Lzz

(Lyy is a term used

by BS5950)

Used in conjunction with LEG for Lvv as per BS5950 table 28 for double angles, note 5.

CB 1.0 1.0 = BS5950 per clause B.2.5 (continuous) to calculate Mb.

2.0 = To calculate Mbs (simple) as per Clause 4.7.7 as opposed to Mb.

DFF None (Mandatory for

deflection check)

"Deflection Length" / Maxm. allowable local deflection

DJ1 Start Joint of member

Joint No. denoting starting point for calculation of "Deflection Length" (See Note 1)

DJ2 End Joint of member

Joint No. denoting end point for calculation of "Deflection Length" (See Note 1)

ESTIFF 0.0 Clauses 4.8.3.3.1 and 4.8.3.3.2 1.0 = Pass if member passes EITHER clause. 1.0 = Pass if member passes BOTH clauses.

Page 116: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-72

Table 2B1.1 - British Steel Design – BS5950:1990 - Parameters

Parameter Name

Default Value Description

WELD 1.0 closed

2.0 open

Weld Type, see AISC steel design 1.0 = Welding on one side only (except for webs of wide

flange and tee sections) 2.0 = Welding on both sides (except pipes and tubes)

TB 0.0 2.0 = Elastic stress analysis 3.0 = Plastic stress analysis

PNL * 0.0 Transverse stiffener spacing (‘a’ in Appendix H1) 0.0 = Infinity Any other value used in the calculations.

SAME ** 0.0 Controls the sections to try during a SELECT process.

0.0 = Try every section of the same type as original 1.0 = Try only those sections with a similar name as

original, e.g. if the original is an HEA 100, then only HEA sections will be selected, even if there are HEM’s in the same table.

! CMN & CMM cannot both be provided. * current units must be considered.

**For angles, if the original section is an equal angle, then the selected section will be an equal angle and vice versa for unequal angles.

NOTE: 1) "Deflection Length" is defined as the length that is used for

calculation of local deflections within a member. It may be noted that for most cases the "Deflection Length" will be equal to the length of the member. However, in some situations, the "Deflection Length" may be different. For example, refer to the figure below where a beam has been modeled using four joints and three members. Note that the "Deflection Length" for all three members will be equal to the total length of the beam in this case. The parameters DJ1 and DJ2 should be used to model this situation. Also the straight line joining DJ1 and DJ2 is used as the reference line from which local deflections are measured. Thus, for all three members here, DJ1 should be "1" and DJ2 should be "4".

Page 117: International Design Codes

Section 2B1 2-73

D = Maximum local deflection for members1, 2 and 3.

D

1

2 3

4

1

2 3

EXAMPLE : PARAMETERS DFF 300. ALL DJ1 1 ALL DJ2 4 ALL

2) If DJ1 and DJ2 are not used, "Deflection Length" will default

to the member length and local deflections will be measured from original member line.

3) The above parameters may be used in conjunction with other

available parameters for steel design.

2B1.7 Design Operations

STAAD contains a broad set of facilities for the design of structural members as individual components of an analysed structure. The member design facilities provide the user with the ability to carry out a number of different design operations. These facilities may be used selectively in accordance with the requirements of the design problem. The operations to perform a design are:

• Specify the load cases to be considered in the design. • Specify design parameter values, if different from the default

values. • Specify whether to perform code checking or member selection

along with the list of members.

These operations may be repeated by the user any number of times depending upon the design requirements.

Page 118: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-74

2B1.8 Code Checking

The purpose of code checking is to ascertain whether the provided section properties of the members are adequate. The adequacy is checked as per BS5950. Code checking is done using the forces and moments at specific sections of the members. If no sections are specified, the program uses the start and end forces for code checking. When code checking is selected, the program calculates and prints whether the members have passed or failed the checks; the critical condition of BS5950 code (like any of the BS5950 specifications for compression, tension , shear, etc.); the value of the ratio of the critical condition (overstressed for value more than 1.0 or any other specified RATIO value); the governing load case, and the location (distance from the start of the member of forces in the member where the critical condition occurs). Code checking can be done with any type of steel section listed in Section 2B.4 of the STAAD Technical Reference Manual or any of the user defined sections in section 5.19 with two exceptions ; GENERAL and ISECTION. In BS5950, these will not be considered for design along with PRISMATIC sections which are also not acceptable.

2B1.9 Member Selection

STAAD is capable of performing design operations on specified members. Once an analysis has been performed, the program can select the most economical section, i.e. the lightest section, which fulfills the code requirements for the specified member. The section selected will be of the same type section as originally designated for the member being designed. Member selection can also be constrained by the parameters DMAX and DMIN which limits the maximum and minimum depth of the members.

Page 119: International Design Codes

Section 2B1 2-75

Member selection can be performed with all the types of steel sections with the same limitations as defined in section 2B.8 - CODE CHECKING. Selection of members, whose properties are originally input from a user created table, will be limited to sections in the user table. Member selection can not be performed on members whose section properties are input as prismatic or as above limitations for code checking.

2B1.10 Tabulated Results of Steel Design

For code checking or member selection, the program produces the results in a tabulated fashion. The items in the output table are explained as follows: a) MEMBER refers to the member number for which the

design is performed. b) TABLE refers to steel section name which has been

checked against the steel code or has been selected.

c) RESULTS prints whether the member has PASSED or FAILED. If the RESULT is FAIL, there will be an asterisk (*) mark on front of the member.

d) CRITICAL COND refers to the section of the BS5950 code

which governs the design. e) RATIO prints the ratio of the actual stresses to

allowable stresses for the critical condition. Normally a value of 1.0 or less will mean the member has passed.

f) LOADING provides the load case number which

governed the design.

Page 120: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-76 g) FX, MY, and MZ provide the axial force, moment in local Y-

axis and the moment in local z-axis respectively. Although STAAD does consider all the member forces and moments (except torsion) to perform design, only FX, MY and MZ are printed since they are the ones which are of interest, in most cases.

h) LOCATION specifies the actual distance from the start

of the member to the section where design forces govern.

i) TRACK If the parameter TRACK is set to 1.0, the

program will block out part of the table and will print the allowable bending capacities in compression (MCY & MCZ) and reduced moment capacities (MRY & MRZ), allowable axial capacity in compression (PC) and tension (PT) and shear capacity (PV). TRACK 2.0 will produce the design results as shown in section 2B.9.

2B1.11 Plate Girders

Plate girders may be considered for design in BS5950. The "py" used in the calculation of compressive strength is reduced by 20N/mm2 as per the code if parameter SBLT is set to 1.0. The code requires that for d/t >63E, the interaction checks be modified in order to check for shear buckling of the web. This is considered in STAAD ( versions 15.0 and over) following clause 4.4.4.2a and 4.4.4.3 of the code. The shear capacity is found from table 21 of the code and used in clause 4.4.5.3. For plate girders, clauses 4.4.2.2a and 4.4.2.3a are also considered. In order to account for these checks, the output has been modified to show these variations from the more common critical checks. An example is as follows, using TRACK 2.0, showing the bottom part of the output having been modified as follows:

Page 121: International Design Codes

Section 2B1 2-77

BS5950 Table 7<note 2>: d/t > 63E Web Is Checked For Shear Buckling d/t =101.7 qcr=191.9 N/mm2 d*t=14639 mm2 (4.4.5.3)Vcr= 2809.4 kN Flange =COMPACT Pyf=344 N/mm2 4.4.2.2 a=PASS 4.4.2.3 a=PASS Flange Ratio 4.4.4.2 (a) =0.20 L= 1 Web Ratio =0.05 L= 1

CRITICAL LOADS FOR EACH CLAUSE CHECK (units- kN,m): CLAUSE RATIO LOAD FX VY VZ MZ MY BS-4.8.3.3.2 0.177 1 0.0 -150.0 0.0 -1125.0 0.0 BS-4.2.3-(Y) 0.049 1 0.0 150.0 0.0 -1125.0 0.0 BS-4.3 (LTB) 0.151 1 0.0 -150.0 0.0 -1125.0 0.0 BS-4.4.5.3 0.053 1 0.0 150.0 0.0 -1125.0 0.0 BS-4.4.4.2 a 0.203 1 0.0 -150.0 0.0 -1125.0 0.0

2B1.12 Composite Sections

The definition of composite sections has been provided for in the standard sections definition - section 5.20.1 of the Technical Reference Manual. This is purely for analysis and for obtaining the right section properties. It uses the American requirement of 18 times depth (CT) as the effective depth. For more control with British sections two new options are available in user provided tables. 1. WIDE FLANGE COMPOSITE:

Using the standard definition of I sections in WIDE FLANGE, 4 additional values can now be provided. The first is the width of concrete to the left of centre of the steel web (b1). The second is the concrete width to the right (b2). The third is the concrete depth (d1) to be considered. The last is the modular ratio. The above values are accepted in the program by adding a '-' at the first position on the first line of data. The program now awaits four extra values on line 2 as described above. If (-) is provided on the second line the program requires another 2 breadths + 1 thickness for the bottom plate.

Page 122: International Design Codes

Steel Design Per BS5950:1990

Section 2B1 2-78 2. ISECTION:

The same is true for ISECTION definition in user table. 3. EXAMPLE INPUT:

UNIT CM WIDE FLANGE C45752 -66.5 44.98 .76 15.24 1.09 21345 645 21.3 34.185 33.223 150 150 30 10 ISECTION PG9144 -92.05 2.15 92.05 42.05 3.66 42.05 3.66 197.9 153.9 1730 40 40 12 1

The larger British sections have been coded as USER TABLES under wide flange and are available on request to any existing user. Please note however that composite design IS NOT available in this portion of STAAD.

Page 123: International Design Codes

2-79

Design Per BS5400

Section 2C

2C.1 General Comments

BS5400 is an additional code available from Research Engineers. It does not come as standard with British versions. The British Standard, BS5400 adopts the limit state design philosophy and is applicable to steel, concrete and composite construction. The code is in 10 parts covering various aspects of bridge design. The implementation of part 3, Code of practice for design of steel bridges, in STAAD is restricted in its scope to simply supported spans. It is assumed that the depth remains constant and both construction and composite stages of steel I-Sections can be checked. The following sections describe in more detail features of the design process currently available in STAAD.

2C.2 Shape Limitations

The capacity of sections could be limited by local buckling if the ratio of flange outstand to thickness is large. In order to prevent this, the code sets limits to the ratio as per clause 9.3.2. In the event of exceeding these limits, the design process will terminate with reference to the clause.

Page 124: International Design Codes

Design Per BS5400

Section 2C 2-80

2C.3 Section Class

Sections are further defined as compact or non-compact. In the case of compact sections, the full plastic moment capacity can be attained. In the case of non compact sections, local buckling of elements may occur prior to reaching the full moment capacity and for this reason the extreme fibre stresses are limited to first yield. In STAAD, section types are determined as per clause 9.3.7 and the checks that follow will relate to the type of section considered.

2C.4 Moment Capacity

Lateral torsional buckling may occur if a member has unrestrained elements in compression. The code deals with this effect by limiting the compressive stress to a value depending on the slenderness parameter which is a modified form of the ratio Le/Ry. Le is the effective length governed by the provision of lateral restraints satisfying the requirements of clause 9.12.1. Once the allowable compressive stress is determined then the moment capacity appropriate to the section type can be calculated. STAAD takes the effective length as that provided by the user, defaulting to the length of the member during construction stage and as zero, assuming full restraint throughout, for the composite stage. The program then proceeds to calculate the allowable compressive stress based on appendix G7 from which the moment capacity is then determined.

2C.5 Shear Capacity

The shear capacity, as outlined in clause is a function of the limiting shear strength, l, which is dependant on the slenderness ratio. STAAD follows the iterative procedure of appendix G8 to determine the limiting shear strength of the web panel. The shear capacity is then calculated based on the formula given under clause 9.9.2.2.

Page 125: International Design Codes

Section 2C 2-81

2C.6 Design Parameters

Available design parameters to be used in conjunction with BS5400 are listed in table 2C.1. Depending on the value assigned to the 'WET' parameter, the users can determine the stage under consideration. For a composite design check, taking into consideration the construction stage, two separate analyses are required. In the first, member properties are non-composite and the WET parameter is set to 1.0 . In the second, member properties should be changed to composite and the WET parameter set to 2.0. Member properties for composite or non-composite sections should be specified from user provided tables (refer to section 5.19 of the manual for specification of user tables). Rolled sections, composite or non-composite, come under WIDE FLANGE section-type and built-up sections under ISECTION. When specifying composite properties the first parameter is assigned a negative value and four additional parameters provided giving details of the concrete section. See user table examples provided.

Table 2C.1 - BS5400 Design Parameters

Parameter Name

Default Value Description

UNL* Member Length

Unsupported Length for calculating allowable compressive bending stress.

PY* Set according to Design Strength of steel SGR

NSF 1.0 Net section factor for tension members.

SGR* 0.0 Steel Grade per BS4360

0.0 = Grade 43

1.0 = Grade 50

2.0 = Grade 55

SBLT 0.0 0.0 = Rolled Section

1.0 = Built up Section

MAIN 1.0 1.0 = Grade of concrete 30 N/mm2

2.0 = Grade of concrete 40 N/mm2

Page 126: International Design Codes

Design Per BS5400

Section 2C 2-82

Table 2C.1 - BS5400 Design Parameters

Parameter Name

Default Value Description

3.0 = Grade of concrete 50 N/mm2

WET 0.0 0.0 = Wet stage with no data saved for composite stage.

1.0 = Wet stage with data saved for composite stage.

2.0 = Composite and wet stage combined.

3.0 = Composite stage only.

TRACK 1.0 1.0 = Print all member capacities.

0.0 = suppress all member capacities.

BEAM 0.0 MUST BE CHANGED TO 1.0 FOR ALL RUNS

LY* Member Length

Length to calculate slenderness ratio for bending about Y-axis.

LZ* Member Length

Length to calculate slenderness ratio for bending about Z-axis.

KY 1.0 K value for bending about Y-axis. Usually this is minor axis.

KZ 1.0 K value for bending about Z-axis. Usually this is major axis.

STIFF 1.0 Factor of length for panel length in the shear calculation.

* Provided in current unit systems.

2C.7 Composite Sections

The definition of composite sections has been provided for in the standard sections definition - section 5.20.1 of the Technical Reference Manual. This is purely for analysis and for obtaining the right section properties. It uses the American requirement of 18 times depth (CT) as the effective depth. For more control with British sections two new options are available in user provided tables.

Page 127: International Design Codes

Section 2C 2-83

1. WIDE FLANGE COMPOSITE: Using the standard definition of I sections in WIDE FLANGE, 4 additional values can now be provided. The first is the width of concrete to the left of centre of the steel web (b1). The second is the concrete width to the right (b2). The third is the concrete depth (d1) to be considered. The last is the modular ratio. The above values are accepted in the program by adding a '-' at the first position on the first line of data. The program now awaits four extra values on line 2 as described above. If (-) is provided on the second line the program requires another 2 breadths + 1 thickness for the bottom plate.

2. ISECTION:

The same is true for ISECTION definition in user table. 3. EXAMPLE INPUT:

UNIT CM WIDE FLANGE C45752 -66.5 44.98 .76 15.24 1.09 21345 645 21.3 34.185 33.223 150 150 30 10 ISECTION PG9144 -92.05 2.15 92.05 42.05 3.66 42.05 3.66 197.9 153.9 1730 40 40 12 1

The larger British sections have been coded as USER TABLES under wide flange and are available on request to any existing user. Please note however that composite design IS NOT available in this portion of STAAD.

Page 128: International Design Codes

Design Per BS5400

Section 2C 2-84

Page 129: International Design Codes

2-85

Design Per BS8007

Section 2D

2D.1 General Comments

BS8007 is an additional code available from Research Engineers. It does not come as standard with British versions. STAAD has the capability of performing concrete slab design according to BS8007. BS8007 provides recommendations for the design of reinforced concrete structures containing aqueous liquids. It is recommended that the design of the structure is carried out according to BS8110, unless modified by the recommendations given in BS8007. Please use the following in conjunction with Section 2A of this Manual - BS8110.

2D.2 Design Process

The design process is carried out in three stages.

1. Ultimate Limit States The program is structured so that ultimate design is first carried out in accordance with recommendations given in BS8110. All active design load cases are considered in turn and a tabulated output is printed showing possible reinforcement arrangements. 12, 16 and 20 mm bars are considered with possible spacings from 100,125,150,175 and 200 mm. Within these spacings, the layout providing the closest area of steel is printed under each bar size. Longitudinal and transverse moments together with critical load

Page 130: International Design Codes

Design Per BS8007

Section 2D 2-86 cases for both hogging and sagging moments are also printed. Minimum reinforcement is in any case checked and provided in each direction. WOOD & ARMER moments may also be included in the design.

2. Serviceability Limit States In the second stage, flexural crack widths under serviceability load cases are calculated. The FIRST and EVERY OTHER OCCURING design load case is considered as a serviceability load case and crack widths are calculated based on bar sizes and spacings proposed at the ultimate limit state check. Crack widths due to longitudinal and transverse moments are calculated directly under bars, midway between and at corners. A tabulated output indicating critical serviceability load cases and moments for top and bottom of the slab is then produced.

3. Thermal crack widths Finally thermal, crack width calculations are carried out. Through available parameters, the user is able to provide information on the type of slab, temperature range and crack width limits. Surface zone depths are determined based on the type of slab and critical areas of reinforcements are calculated and printed in a tabulated form. Four bar sizes are considered and for each, max crack spacing, Smax and crack widths are calculated for the critical reinforcements and printed under each bar size. Maximum bar spacing to limit crack widths to the user's limit is also printed under each bar size.

Page 131: International Design Codes

Section 2D 2-87

2D.3 Design Parameters

The program contains a number of parameters which are needed to perform and control the design to BS8007. These parameters not only act as a method to input required data for code calculations but give the Engineer control over the actual design process. Default values of commonly used values for conventional design practice have been chosen as the basis. Table 2D.1 contains a complete list of available parameters with their default values.

2D.4 Structural Model

Structural slabs that are to be designed to BS8007 must be modelled using finite elements. The manual provides information on the sign convention used in the program for defining elements, (See main manual section 2-6). It is recommended to connect elements in such a way that the positive local z axis points outwards away, from the centre of the container. In this manner the "Top" of elements will consistently fall on the outer surface and internal pressure loads will act in the positive direction of the local z axis. An example of a rectangular tank is provided to demonstrate the above procedure. Element properties are based on the thickness given under ELEMENT PROPERTIES command. The following example demonstrates the required input for a 300 mm slab modelled with 10 elements.

Page 132: International Design Codes

Design Per BS8007

Section 2D 2-88

UNIT MM ELEMENT PROPERTIES 1 TO 10 THI 300.0

2D.5 Wood & Armer Moments

This is controlled by the SRA parameter. If the default value of zero is used, the design will be based on the Mx and My moments which are the direct results of STAAD analysis. The SRA parameter (Set Reinforcement Angle) can be manipulated to introduce WOOD & ARMER moments into the design replacing the pure Mx, My moments. These new design moments allow the Mxy moment to be considered when designing the section. Orthogonal or skew reinforcement may be considered. SRA set to -500 will assume an orthogonal layout. If however a skew is to be considered, an angle is given in degrees, measured between the local element x axis anti-clockwise ( positive ). The resulting Mx* and My* moments are calculated and shown in the design format.

Page 133: International Design Codes

Section 2D 2-89

Table 2D.1 - BS8007 Design Parameters

Parameter Name

Default Value Description

FYMAIN * * 460 N/mm2 Yield for all reinforcing steel

FC * 30 N/mm2 Concrete grade.

CLEAR * 20 mm Distance from the outer surface to the edge of the bar. This is considered the same on both surfaces.

SRA 0.0 Orthogonal reinforcement layout without considering torsional moment Mxy - slabs on -500. orthogonal reinforcement layout with Mxy used to calculate WOOD &ARMER moments for design. A* Skew angle considered in WOOD & ARMER EQUATIONS. A* is any angle in degrees.

SCON 1 Parameter which indicates the type of slab ee. ground or suspended as defined in BS8007 1 = Suspended Slab 2 = Ground Slab

TEMP 30°C Temperature range to be considered in thermal crack width calculations

CRACK * 0.2 mm Limiting thermal crack width

* Provided in current unit systems

Page 134: International Design Codes

Design Per BS8007

Section 2D 2-90

Page 135: International Design Codes

2-91

Design Per British Cold Formed Steel Code

Section 2E

2E.1 General

Provisions of BS 5950-5:1998, have been implemented. The program allows design of single (non-composite) members in tension, compression, bending, shear, as well as their combinations. Cold work of forming strengthening effects have been included as an option.

2E.2 Cross-Sectional Properties

The user specifies the geometry of the cross-section by selecting one of the section shape designations from the Gross Section Property Tables published in the “The Steel Construction Institute”, (Design of Structures using Cold Formed Steel Sections). The Tables are currently available for the following shapes:

• Channel with Lips • Channel without Lips • Z with Lips • Pipe • Tube

Shape assignment may be done using the member property pages of the graphical user interface (GUI) or by specifying the section designation symbol in the input file.

Page 136: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-92 The properties listed in the tables are gross section properties. STAAD.Pro uses unreduced section properties in the structure analysis stage. Both unreduced and effective section properties are used in the design stage, as applicable.

2E.3 Design Procedure

The following two design modes are available:

1. Code Checking

The program compares the resistance of members with the applied load effects, in accordance with BS 5950-5:1998. Code checking is carried out for locations specified by the user via the SECTION command or the BEAM parameter. The results are presented in a form of a PASS/FAIL identifier and a RATIO of load effect to resistance for each member checked. The user may choose the degree of detail in the output data by setting the TRACK parameter.

2. Member Selection

The user may request that the program search the cold formed steel shapes database (BS standard sections) for alternative members that pass the code check and meet the least weight criterion. In addition, a minimum and/or maximum acceptable depth of the member may be specified. The program will then evaluate all database sections of the type initially specified (i.e., channel, angle, etc.) and, if a suitable replacement is found, presents design results for that section. If no section satisfying the depth restrictions or lighter than the initial one can be found, the program leaves the member unchanged, regardless of whether it passes the code check or not.

Page 137: International Design Codes

Section 2E 2-93

The program calculates effective section properties in accordance with Section 4 of the subject code. Cross-sectional properties and overall slenderness of members are checked for compliance with • Clause 6.2.2, Maximum Effective Slenderness Ratio for

members in Compression

• Clause 4.2, Maximum Flat Width Ratios for Elements in Compression

2E.4 Design Equations

Tensile Strength The allowable tensile strength, as calculated in STAAD as per BS5950-5, section 7 is described below. The tensile strength, Pt of the member should be determined from clause 7.2.1 t ye pAP =

Where Ae is the net area An determined in accordance with cl.3.5.4 py is the design strength Combined bending and tension As per clause 7.3 of BS 5950-5:1998 members subjected to both axial tension and bending should be proportioned such that the following relationships are satisfied at the ultimate limit state

1≤++cy

y

cz

z

t

t

MM

MM

PF

And

≤cz

z

MM

1

Page 138: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-94 and

≤cy

y

MM

1

here

Pt in accordance with

z,My,Mcz,Mcy are as defined in clause 6.4.2 of the subject code

ompressive Strength

W Ft is the applies tensile strength

is the tensile capacity determinedclause 7.2.1 of the subject code

M C

ulated in STAAD as er BS5950-5, section 6 is described below

the following equation as per clause 6.2.3 of the ubject code

The allowable Compressive strength, as calcp For sections symmetrical about both principal axes or closedcross-sections which are not subjected to torsional flexural buckling, the buckling resistance under axial load, Pc, may be obtained froms

csE

csE

PP

PPPc

−+=

2φφ

For Sections symmetrical about a single axis and which are not ubject to torsional flexural buckling, the buckling resistance nder axial load, Pc, may be obtained from the following equation s per clause 6.2.4 o he subject code

sua f t

)(

'cc

ccc PM

PMP

+=

se

bols used are indicated in the ubject clauses.

Where the meanings of the syms

Page 139: International Design Codes

Section 2E 2-95

Torsional flexural buckling Design of the members which have at least one axis of symmand which are subject to torsional flexural buckling should be done according to the stipulations of the clause 6.3.2 using

etry,

ctored slenderness ratio αLE/r in place of actual slenderness ratio d e 10 for the value of Compressive strength(pc).

fawhile rea ing Tabl Where

2/1

⎟⎟⎠

⎞⎜⎜⎝

⎛=

TF

E

PP

α when PE > PTF

α = 1 , otherwise Where the meanings of the symbols used are indicated in the subject clause. Combined bending and compression M bers subjected to both axial compression and bending should

e checked for local capacity and overall buckling em b

ocal capacity check as per clause 6.4.2 of the subject codeL

1≤++cy

yzc MMF

czcs MMP Overall buckling check as per clause 6.4.3 of the subject code

e satisfied For Beams not subjected to lateral buckling, the following relationship should b

1

11⎟⎟

⎜⎜ −⎟⎜ − c

cybyczbxP

MCPM

≤⎞⎛

++ yz

F

M

C

M

ea g relationship d

⎠⎝⎠⎝ EyEz

⎟⎞

⎜⎛ cc FP

cF

For B ms subjected to lateral buckling, the followinshoul be satisfied

Page 140: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-96

1

1 ⎟⎟⎞

⎜⎜⎛− c

cybybc F

MCP

≤+MM

Fc

Mz applied bending moment about z axis y is the applied bending moment about y axis

lause 5.2.2 and 5.6

cy about the local Y axis, s per clause 5.2.2 and 5.6

t the local Z axis is the flexural buckling load in compression for bending

t the local Y axis aken as unity unless their values are specified by the

user

he Mcz, Mcy and Mb are calculated from mbers 5.2.2 and 5.6 in the manner described hereinbelow.

+ yzc MF

⎠⎝ EyPis the applied axial load

Pcs is the short strut capacity as per clause 6.2.3 is the

M Mcz is the moment capacity in bending about the local Z axis in

the absence of Fc and My, as per cis the moment capacity in bending Min the absence of Fc and Mz,a

Mb is the lateral buckling resistance moment as per clause

5.6.2 PEz is the flexural buckling load in compression for bending

abou PEy

abouCbz,Cby are t

T clause nu

Calculation of moment capacities For r rained beams, the applied moment based on factoreest s

uld d load

sho not be greater then the bending moment resistance of the Msection, c

Mcz = Szz × po

Mcy = Syy × po

ysw

o pY

tD

p ⎟⎟

⎜⎜⎝

⎟⎞

⎜⎛−=

2800019.013.1

⎞⎛

⎠⎝

2/1

ere cz is the Moment resistance of the section in z axis

is the Moment resistance of the section in z axis o is the limiting stress for bending elements under stress

gradient and should not greater then design strength py

WhMMcz

p

Page 141: International Design Codes

Section 2E 2-97

For unrestrained beams the applied moment based on factored ads should not be great han the smaller of the bending

nt

lo er tmoment resistance of the section , Mc , and the buckling resistance mome of the beam, Mb

Then buckling resistance moment, Mb, may be calculated as follows

cYE MMMM ≤

YEBB

Where

bMM−+

=2φφ

2)1( EY

BM

φ = Mη++

and elastic modules of the gross section with respect to the compression flange Zc

Please refer clause numbers 5.2.2 and 5.6 of the subject code for a detailed discussion regarding the parameters used in the abovementioned equations. Shear Strength

MY is the yield moment of the section , product of design strength py

ME is the elastic lateral buckling resistance as per clause 5.6.2.2 η is the Perry coefficient

The maximum shear stress should not be greater then 0.7 × py as per clause 5.4.2 The average shear stress should not exceed the lesser of the shear yield strength, pv or the shear buckling strength, qcr as stipulated in clause 5.4.3 of the subject code.

Page 142: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-98 The parameters are calculated as follows :- pv = 0.6 × py

22

/1000 Ntqcr ⎟⎞

⎜⎛= mm

D ⎠⎝

in(pv,qcr)

ere

^2 /mm^2

is the web thickness in mm

Pv = A*M Wh Pv is the shear capacity in N/mm py is the design strength in N t D is the web depth in mm Combined bending and Shear For beam webs subjected to both bending and shear stresses the member should be designed to satisfy the following relationship as per the stipulations of clause 5.5.2 of the subject code

122

≤⎟⎟⎠

⎞⎜⎜⎝

⎛+⎟⎟⎜⎜

v

P ⎠

⎞⎛

cv MMF

re

M ending moment acting at the same section as Fv c is the moment capacity determined in accordance with

The next table contains the input parameters for specifying values of design variables and selection of design options.

⎝Whe Fv is the shear force

is the b M

5.2.2

Page 143: International Design Codes

Section 2E 2-99

BRITISH COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value

Description

BEAM 1.0 When this parameter is set to 1.0 (default), the adequacy of the member is determined by checking a total of 13 equally spaced locations along the length of the member. If the BEAM value is 0.0, the 13 location check is not conducted, and instead, checking is done only at the locations specified by the SECTION command (See STAAD manual for details. For TRUSS members only start and end locations are designed.

CMZ 1.0 Coefficient of equivalent uniform bending Cb. See BS:5950-5:1998,5.6. Used for Combined axial load and bending design.

CMY 1.0 Coefficient of equivalent uniform bending Cb. See BS:5950-5:1998,5.6. Used for Combined axial load and bending design.

CWY 1.0 Specifies whether the cold work of forming strengthening effect should be included in resistance computation. See BS:5950-5:1998,3.4

Values: 0 – effect should not be included

1 – effect should be included

FLX 1 Specifies whether torsional-flexural buckling restraint is provided or is not necessary for the member. See BS:5950-5:1998, 5.6

Values:

0 – Section not subject to torsional flexural buckling 1 – Section subject to torsional flexural buckling

FU 430 MPa

Ultimate tensile strength of steel in current units.

FYLD 250 MPa

Yield strength of steel in current units.

Page 144: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-100

BRITISH COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value

Description

KX 1.0 Effective length factor for torsional buckling. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the capacity in axial compression.

KY 1.0 Effective length factor for overall buckling about the local Y-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

KZ 1.0 Effective length factor for overall buckling in the local Z-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a member completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

LX Member length

Unbraced length for twisting. It is input in the current units of length. Values can range from 0.01 (for a member completely prevented from torsional buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the capacity in axial compression.

LY Member length

Effective length for overall buckling in the local Y-axis. It is input in the current units of length. Values can range from 0.01 (for a member completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

Page 145: International Design Codes

Section 2E 2-101

BRITISH COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value

Description

LZ Member length

Effective length for overall buckling in the local Z-axis. It is input in the current units of length. Values can range from 0.01 (for a member completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

MAIN 0 0 – Check slenderness ratio

0 – Do not check slenderness ratio

NSF 1.0 Net section factor for tension members DMAX

2540.0 cm. Maximum allowable depth. It is input in the current units of

length.

RATIO 1.0 Permissible ratio of actual to allowable stresses

TRACK 0 This parameter is used to control the level of detail in which the design output is reported in the output file. The allowable values are: 0 - Prints only the member number, section name, ratio,

and PASS/FAIL status. 1 - Prints the design summary in addition to that printed by

TRACK 1 2 - Prints member and material properties in addition to that

printed by TRACK 2.

2E.5 Verification Problem

In the next few pages are included a verification example for reference purposes.

Page 146: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-102

Verification Problem-1

In this problem, we have assigned Channel sections with lips to different members.Member numbers 28 to 31 have been assigned section 230CLHS66X16,member numbers 3 TO 6 and 15 TO 19 have been assigned the section 230CLMIL70X30 and member numbers 1, 2, 7 TO 14 have been assigned the section 170CLHS56X18. These members have been designed as per BS 5950 Part 5. Other sections have been assigned from the AISI shapes database (American cold-formed steel) and designed in accordance with that code. The excerpts from the design output for member number 1 are given herein below.

Page 147: International Design Codes

Section 2E 2-103

1) Bending Check As per Clause 5.2.2.2 of BS 5950 –Part 5 the limiting compressive stress(po ) for stiffened webs is given by the minimum of

ysw

op = pY

tD

⎟⎟⎞

⎜⎜⎛

⎟⎠⎞

⎜⎝⎛−

2/1

2800019.013.1

po = Py where Py = Min ( FYLD, 0.84XFU) = 361.2 N/mm2

⎠⎝ And

So that

2.361280

212.2798.1

1700019.013.12/1

⎟⎟⎠

⎞⎜⎜⎝

⎛⎟⎠⎞

⎜⎝⎛−=op

= 332.727 N/mm2

The limiting compressive moments in local Y and Z axes

y will be given

cz zz o 6

cy yy o

06 = 0.0057 ……hence verified

ment Mb

The buckling resistance moment

b = S × p = 27632.4 X 332.727 = 9.19 X 10 M N-mm

= S × p = 27632.4 X 5427.50 = 3.46 X 10M 6 N-mm

Ma um bending moment about local Z = 2159 N-m at node 7 xim

aximum bending moment about local Y = 19.755 N-m at node 7 M

ending Ratio Z = 2.15 X10B 6 / 9.19 X106 = 0.235 ……hence verified Bending Ratio Y = 19755.3 / 3.46 X1

uckling resistance moB

As per section 5.6.2,

c

YEBB

YEb M

MM

MMM ≤−+

=2φφ

Page 148: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-104 Where, The Yield moment(MY) of section is given by MY = Szz × po = 9.19 X 106 N-mm The elastic buckling resistance moment(ME ) as per clause 5.6.2.2 is calculated to be 4.649 X106 N-mm

And, 2)1( EY

BMM η

φ++

=, so that

210649.4)0.01(1019.9 6 +× 6×+

= = 2.325 X 1010

Which gives

662101010325.2 +×

66

1019.910649.4)10325.2(1019.910649.4

×××−×

×××=b

9.98 X 106 N-mm

2)

he short strut capacity (Pcs ) is given by Aeff X py = 457.698 *

Perry η) = 0.0207

M

=

Compression Check

The Axial force induced in member# 1 is 3436.75 N The elastic flexural buckling load PE = 1.185 X 106 N T344 = 157448 N

Coefficient ( 4

=φ [Pcs + (1+η ) EP× ]×0.5 = 683512.45 N

Buckling resistance csE PP−+ φφ = 153782 N

csE PPPc =

2

Page 149: International Design Codes

Section 2E 2-105

For Channel section( eb ing singly symmetric) as per clause 6.2.4

Buckling resistance )( sccc ePM +

' cc PMP =

= 6 N-mm,as calculated above

nd the distance(es) of the geometric neutral axis of the gross at ffective cross section = 38.24 m

=

Where The limiting compressive moment(Mc) in the relevant direction9.19 X 10 Across section and th of the e

o that, S

cP′ 24.385378211019.91537821019.9

6

6

×+×××

pression ratio =

= 93788.7 N

Com0366.075.3436

=7.93788 ……hence verified

3) xial Compression and Bending Local capacity check as per clause 6.4.2

A

1≤++ yzc MMF

cyczcs MMP

66 1081.11019.9212.379698.457

6 19755 3.1015.275.3436×

+××

= 0.26 Over all buckling check : 6 4.3

=

.

1

11≤

⎟⎟⎠

⎞⎜⎜⎝

⎛−

+

⎟⎟⎠

⎜⎝

byEz

czbx P⎞⎛ cc FP

⎜ −Ey

ccy

y

PF

MC

M

MC

……hence verified

+ zc MF

= 0.2773

Page 150: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-106 4) hear Check as per clause 5.4.2 and 5.4.3

pv = 0.6 × p = 0.6 × 379.212 = 227.52 N/mm2

S

y

2/1000 mmNtq ⎟⎞

⎜⎛=

2

Dcr⎠⎝

2

170⎟⎠

⎜⎝

=crq2

8.11000 ⎞⎛ ×

= 112.11 N/mmv = A*Min(pv,qcr) = 112.11 N/mm2

Shear resistance Y = 33579.4 N

hear re istance = 21

Shear Ratio Y =

P

S s Z 148.6 N

1675.04.33579

72.5627=

……hence verified

Shear Ratio Z = 0031.0

21=

6.148 ……hence verified

5) Shear Check with Bending as per clause 5.5.2

Shear with bending on Z =

114.67

122

≤⎟⎟⎠

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

cz

z

v

v

MM

PF

=

2

6

62

1019.91015.2

4.3357972.5627

⎟⎟⎠

⎞⎜⎜⎝

⎛××

+⎟⎠⎞

⎜⎝⎛

= 0.08327 …… hence verified

Shear with bending on Y =

122

≤⎟⎟⎠

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

cy

y

v

v

MM

PF

=

2

6

2

1046.33.19755

6.21148114.67

⎟⎠⎞

⎜⎝⎛

×+⎟

⎠⎞

⎜⎝⎛

= 0.000….426 ……hence verified

Page 151: International Design Codes

Section 2E 2-107

Input File: STAAD SPACE SET ECHO OFF INPUT WIDTH 79 UNIT FEET KIP JOINT COORDINATES 1 0 5 0; 2 0 5 10; 3 10 5 0; 4 10 5 10; 5 5 5 0; 6 5 5 10; 7 0 5 2; 8 0 5 4; 9 0 5 6; 10 0 5 8; 11 10 5 2; 12 10 5 4; 13 10 5 6; 14 10 5 8; 15 5 5 2; 16 5 5 4; 17 5 5 6; 18 5 5 8; 19 10 0 0; 20 10 0 10; 21 0 0 10; 22 0 0 0; MEMBER INCIDENCES 1 1 7; 2 3 11; 3 1 5; 4 2 6; 5 5 3; 6 6 4; 7 7 8; 8 8 9; 9 9 10; 10 10 2; 11 11 12; 12 12 13; 13 13 14; 14 14 4; 15 5 15; 16 15 16; 17 16 17; 18 17 18; 19 18 6; 20 7 15; 21 15 11; 22 8 16; 23 16 12; 24 9 17; 25 17 13; 26 10 18; 27 18 14; 28 1 22; 29 2 21; 30 3 19; 31 4 20; 32 1 21; 33 21 4; 34 4 19; 35 19 1; 36 2 20; 37 20 3; 38 3 22; 39 22 2; MEMBER PROPERTY COLDFORMED AMERICAN 32 TO 39 TABLE ST 3LU3X060 20 TO 27 TABLE ST 3HU3X075 MEMBER PROPERTY COLDFORMED BRITISH 28 TO 31 TABLE ST 230CLHS66X16 3 TO 6 15 TO 19 TABLE ST 230CLMIL70X30 1 2 7 TO 14 TABLE ST 170CLHS56X18 UNIT MMS PRINT MEMBER PROPERTIES LIST 32 20 28 3 1 SUPPORTS 19 TO 22 PINNED UNIT FEET DEFINE MATERIAL START ISOTROPIC STEEL E 4.176e+006 POISSON 0.3 DENSITY 0.489024 ALPHA 6.5e-006 DAMP 0.03 END DEFINE MATERIAL CONSTANTS BETA 90 MEMB 20 TO 27 MATERIAL STEEL MEMB 1 TO 39 MEMBER TENSION 32 TO 39 UNIT FEET KIP LOAD 1 VERTICAL AND HORIZONTAL MEMBER LOAD 3 TO 6 20 TO 27 UNI GY -0.3 0 5 JOINT LOAD 1 2 FX 0.6 2 4 FZ -0.6 PERFORM ANALYSIS PRINT STATICS CHECK UNIT KGS CM

Page 152: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-108 PRINT JOINT DISP LIST 1 4 16 PRINT SUPPORT REACTIONS PRINT MEMBER FORCES LIST 3 24 28 UNIT KIP INCH PARAMETER 1 CODE AISI FYLD 55 ALL CWY 1 ALL BEAM 1 ALL TRACK 2 ALL CHECK CODE MEMB 20 21 PARAMETER 2 CODE BS5950 COLD TRACK 2 MEMB 1 TO 19 28 TO 31 CHECK CODE MEMB 1 2 FINISH Output File: **************************************************** * * * STAAD.Pro * * Version Bld * * Proprietary Program of * * * * Date= * * Time= * * * * USER ID: * **************************************************** 1. STAAD SPACE 2. SET ECHO OFF MEMBER PROPERTIES. UNIT - CM ----------------- MEMB PROFILE AX/ IZ/ IY/ IX/ AY AZ SZ SY 32 ST 3LU3X060 2.26 21.81 5.17 0.02 1.51 1.51 4.05 1.93 20 ST 3HU3X075 4.91 63.15 40.66 0.06 1.24 2.40 10.63 9.59 28 ST 230CLHS66X16 8.78 663.30 42.82 0.18 5.40 2.94 60.93 9.29 3 ST 230CLMIL70X30 11.40 868.90 66.93 0.36 6.72 3.84 80.13 14.15 1 ST 170CLHS56X18 5.23 224.50 20.49 0.06 3.00 1.89 27.96 5.43 ************ END OF DATA FROM INTERNAL STORAGE ************ **START ITERATION NO. 2 **NOTE-Tension/Compression converged after 2 iterations, Case= 1 STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 1 VERTICAL AND HORIZONTAL

Page 153: International Design Codes

Section 2E 2-109

***TOTAL APPLIED LOAD ( KIP FEET ) SUMMARY (LOADING 1 ) SUMMATION FORCE-X = 1.20 SUMMATION FORCE-Y = -18.00 SUMMATION FORCE-Z = -1.20 SUMMATION OF MOMENTS AROUND THE ORIGIN- MX= 84.00 MY= 12.00 MZ= -96.00 ***TOTAL REACTION LOAD( KIP FEET ) SUMMARY (LOADING 1 ) SUMMATION FORCE-X = -1.20 SUMMATION FORCE-Y = 18.00 SUMMATION FORCE-Z = 1.20 SUMMATION OF MOMENTS AROUND THE ORIGIN- MX= -84.00 MY= -12.00 MZ= 96.00 MAXIMUM DISPLACEMENTS ( INCH /RADIANS) (LOADING 1) MAXIMUMS AT NODE X = 1.56266E-02 1 Y = -4.80071E-01 16 Z = -1.74873E-02 4 RX= -8.28375E-03 6 RY= -2.10910E-05 14 RZ= -8.31623E-03 7 ************ END OF DATA FROM INTERNAL STORAGE ************ JOINT DISPLACEMENT (CM RADIANS) STRUCTURE TYPE = SPACE ------------------ JOINT LOAD X-TRANS Y-TRANS Z-TRANS X-ROTAN Y-ROTAN Z-ROTAN 1 1 0.0397 -0.0184 -0.0339 0.0074 0.0000 -0.0027 4 1 0.0305 -0.0185 -0.0444 -0.0074 0.0000 0.0025 16 1 0.0352 -1.2194 -0.0392 0.0025 0.0000 0.0000 ************** END OF LATEST ANALYSIS RESULT ************** SUPPORT REACTIONS -UNIT KGS CM STRUCTURE TYPE = SPACE ----------------- JOINT LOAD FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM Z 19 1 -447.32 2312.64 85.08 0.00 0.00 0.00 20 1 -447.10 2041.85 186.39 0.00 0.00 0.00 21 1 174.26 1768.33 187.79 0.00 0.00 0.00 22 1 175.85 2041.85 85.05 0.00 0.00 0.00 ************** END OF LATEST ANALYSIS RESULT ************** MEMBER END FORCES STRUCTURE TYPE = SPACE ----------------- ALL UNITS ARE -- KGS CM (LOCAL ) MEMBER LOAD JT AXIAL SHEAR-Y SHEAR-Z TORSION MOM-Y MOM-Z 3 1 1 669.42 1448.06 2.70 -1.68 -215.75 61582.12 5 -669.42 -767.67 -2.70 1.68 -196.10 107256.50 24 1 9 -0.63 -0.06 -285.30 -0.04 -0.08 1.04 17 0.63 0.06 -395.09 0.04 -8366.18 -9.62 28 1 1 2155.98 -404.11 -85.05 0.00 12961.01 -61586.40 22 -2155.98 404.11 85.05 0.00 0.00 0.00 ************** END OF LATEST ANALYSIS RESULT **************

Page 154: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-110 STAAD.Pro CODE CHECKING - (AISI) *********************** UNITS ARE: IN, KIP, KIP-IN, KSI |-----------------------------------------------------------------------------| | MEMBER# 20 SECTION: 3HU3X075 LEN: 60.00 GOV.LOC: 60.00 | | STATUS: PASS RATIO = 0.285 GOV.MODE: Bend + Compress GOV.LOAD: 1 | | | | RESISTANCES: AX.TENS: 0.00 ECC.TENS: 0.00 COMPRESS: 7.51 | | BEND. Z: 28.21 BEND. Y: 30.98 SHEAR Z: 11.76 SHEAR Y: 5.88 | | | | FYLD: 55.00 COLD WORK FYLD: 55.71 FU: 58.00 A: 0.76 AE: 0.76 | | IZ: 1.5173E+00 IZE: 1.5173E+00 IY: 9.7684E-01 IYE: 9.7684E-01 | | SZE_T: 6.4841E-01 SZE_C: 6.4841E-01 SYE_T: 5.8539E-01 SYE_C: 7.3374E-01 | |-----------------------------------------------------------------------------| |-----------------------------------------------------------------------------| | MEMBER# 21 SECTION: 3HU3X075 LEN: 60.00 GOV.LOC: 0.00 | | STATUS: PASS RATIO = 0.285 GOV.MODE: Bend + Compress GOV.LOAD: 1 | | | | RESISTANCES: AX.TENS: 0.00 ECC.TENS: 0.00 COMPRESS: 7.51 | | BEND. Z: 28.21 BEND. Y: 30.98 SHEAR Z: 11.76 SHEAR Y: 5.88 | | | | FYLD: 55.00 COLD WORK FYLD: 55.71 FU: 58.00 A: 0.76 AE: 0.76 | | IZ: 1.5173E+00 IZE: 1.5173E+00 IY: 9.7684E-01 IYE: 9.7684E-01 | | SZE_T: 1.0115E+00 SZE_C: 1.0115E+00 SYE_T: 7.3374E-01 SYE_C: 5.8539E-01 | |-----------------------------------------------------------------------------|

Page 155: International Design Codes

Section 2E 2-111

STAAD/Pro CODE CHECKING - (BS5950-5-v1.0) *********************** UNITS : MM, KN, KNM, MPA ------------------------------------------------------------------------------- | MEMBER# 1 SECTION: 170CLHS56X18 LEN: 609.60 LOCATION: 609.60 | | STATUS: PASS RATIO = 0.277 GOV.MODE: Bend + Compress GOV.LOAD: 1 | |------------------------------------------------ --------------------------| MATERIAL DATA: Yield strength of steel: 379.21 N/mm2 Ultimate tensile strength: 430.00 N/mm2 SECTION PROPERTIES:(units - cm) Section Name: 170CLHS56X18 Member Length: 60.96 Gross Area(Ag): 5.46 Net Area (Ae): 4.58 z-z axis y-y axis Moment of inertia (I) : 237.68 21.99 Moment of inertia (Ie): 236.04 19.44 Elastic modulus (Zet): 27.91 5.21 Elastic modulus (Zec): 27.63 10.41 DESIGN DATA: z-z axis y-y axis Tension Capacity (Pt): 0.00 Compression Capacity (Pc): 93.79 Moment Capacity (Mc): 9.19 3.46 Shear Capacity (Pc): 21.15 33.58 EACH CLAUSE CHECK UNDER CRITICAL LOAD : CLAUSE COMBINATION RATIO BS-6.3 Compression ratio - Axial 0.037 BS-6.4 Bend-Compression ratio 0.277 BS-5.1 Bending Ratio - Z 0.235 BS-5.1 Bending Ratio - Y 0.006 BS-5.1 Biaxial Bending Ratio 0.241 BS-5.4 Shear Ratio - Z 0.168 BS-5.4 Shear Ratio - Y 0.003 BS-5.5.2 Bending -Z & Shear - Y Ratio 0.083 BS-5.5.2 Bending -Y & Shear - Z Ratio 0.000

Page 156: International Design Codes

Design Per British Cold Formed Steel Code

Section 2E 2-112 ------------------------------------------------------------------------------- | MEMBER# 2 SECTION: 170CLHS56X18 LEN: 609.60 LOCATION: 609.60 | | STATUS: PASS RATIO = 0.282 GOV.MODE: Bend + Compress GOV.LOAD: 1 | |------------------------------------------------ --------------------------| MATERIAL DATA: Yield strength of steel: 379.21 N/mm2 Ultimate tensile strength: 430.00 N/mm2 SECTION PROPERTIES:(units - cm) Section Name: 170CLHS56X18 Member Length: 60.96 Gross Area(Ag): 5.46 Net Area (Ae): 4.58 z-z axis y-y axis Moment of inertia (I) : 237.68 21.99 Moment of inertia (Ie): 236.04 21.99 Elastic modulus (Zet): 27.91 14.20 Elastic modulus (Zec): 27.63 5.43 DESIGN DATA: z-z axis y-y axis Tension Capacity (Pt): 0.00 Compression Capacity (Pc): 93.79 Moment Capacity (Mc): 9.19 1.81 Shear Capacity (Pc): 21.15 33.58 EACH CLAUSE CHECK UNDER CRITICAL LOAD : CLAUSE COMBINATION RATIO BS-6.3 Compression ratio - Axial 0.037 BS-6.4 Bend-Compression ratio 0.282 BS-5.1 Bending Ratio - Z 0.235 BS-5.1 Bending Ratio - Y 0.010 BS-5.1 Biaxial Bending Ratio 0.245 BS-5.4 Shear Ratio - Z 0.168 BS-5.4 Shear Ratio - Y 0.003 BS-5.5.2 Bending -Z & Shear - Y Ratio 0.083 BS-5.5.2 Bending -Y & Shear - Z Ratio 0.000 *********** END OF THE STAAD.Pro RUN ***********

Page 157: International Design Codes

Section 3 Canadian Codes

Page 158: International Design Codes

Aksf;ldkjasd

Page 159: International Design Codes

3-1

Concrete Design Per CSA Standard A23.3-94

Section 3A

3A.1 Design Operations

STAAD can perform design of concrete beams, columns and slabs according to CSA STANDARD A23.3-94. Given the dimensions of a section, STAAD will calculate the required reinforcement necessary to resist the various input loads.

3A.2 Section Types for Concrete Design

The following types of cross sections for concrete members can be designed. For Beams Prismatic (Rectangular, Square & Tee) For Columns Prismatic (Rectangular, Square and Circular) For Slabs 4-noded Plate Elements

3A.3 Member Dimensions

Concrete members that are to be designed by STAAD must have certain section properties input under the MEMBER PROPERTIES command. The following example demonstrates the required input:

Page 160: International Design Codes

Concrete Design Per CSA Standard A23.3-94

Section 3A 3-2

UNIT MM MEMBER PROPERTIES 1 3 TO 7 9 PRISM YD 450. ZD 300. 11 14 PR YD 300.

In the above input, the first set of members are rectangular (450mm depth and 300mm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with a 300mm diameter.

3A.4 Slenderness Effects and Analysis Considerations

STAAD provides the user with two methods of accounting for the slenderness effect in the analysis and design of concrete members. The first method is equivalent to the procedure presented in CSA STANDARD A23.3-94 Clause 10.13. STAAD accounts for the secondary moments, due to axial loads and deflections, when the PDELTA ANALYSIS command is used. After solving for the joint displacements of the structure, the program calculates the additional moments induced in the structure due to the P-Delta effect. Therefore, by performing a PDELTA ANALYSIS, member forces are calculated which will require no user modification before beginning member design. The second method by which STAAD allows the user to account for the slenderness effect is through user supplied moment magnification factors (see the parameter MMAG in Table 3A.1). Here the user approximates the additional moment by supplying a factor by which moments will be multiplied before beginning member design. This second procedure allows slenderness to be considered in accordance with Clause 10.14 of the code.

It should be noted that STAAD does not factor loads automatically for concrete design. All the proper factored loads must be provided by the user before the ANALYSIS specification.

Page 161: International Design Codes

Section 3A 3-3

While performing a PDELTA ANALYSIS, all load cases must be defined as primary load cases. If the effects of separate load cases are to be combined, it should be done either by using the REPEAT LOAD command or by specifying the load information of these individual loading cases under one single load case. Usage of the LOAD COMBINATION command will yield incorrect results for PDELTA ANALYSIS.

3A.5 Design Parameters

The program contains a number of parameters which are needed to perform design per CSA STANDARD A23.3-94. These parameters not only act as a method to input required data for code calculations but give the engineer control over the actual design process. Default values, which are commonly used numbers in conventional design practice, have been used for simplicity. Table 3A.1 contains a list of available parameters and their default values. It is necessary to declare length and force units as Millimeter and Newton before performing the concrete design.

Table 3A.1 - Canadian Concrete Design -CSA-A23.3-94 Parameters

Parameter Default Description Name Value

FYMAIN 400N/mm2 Yield Stress for main reinforcing steel.

FYSEC 400 N/mm2 Yield Stress for secondary reinforcing steel.

FC 30 N/mm2 Specified compressive strength of concrete.

CLT 40mm Clear cover to reinforcing bar at top of cross section.

CLB 40mm Clear cover to reinforcing bar at bottom of cross section.

CLS 40mm Clear cover to reinforcing bar along the side of the cross section.

MINMAIN Number 10 bar Minimum main reinforcement bar size

MINSEC Number 10 bar Minimum secondary (stirrup) reinforcement bar size.

Page 162: International Design Codes

Concrete Design Per CSA Standard A23.3-94

Section 3A 3-4

Table 3A.1 - Canadian Concrete Design -CSA-A23.3-94 Parameters

Parameter Default Description Name Value

MAXMAIN Number 55 bar Maximum main reinforcement bar size.

SFACE 0.0 Distance of face of support from start node of beam. Used for shear and torsion calculation.

EFACE 0 Face of Support Distance of face of support from end node of beam. Used for shear and torsion calculation. (Note: Both SFACE and EFACE are input as positive numbers).

REINF 0.0 Tied Column. A value of 1.0 will mean spiral.

TRACK 0.0 For TRACK = 0.0, Critical Moment will not be printed out with beam design report. For TRACK=1.0, moments will be printed.

MMAG 1.0 A factor by which the column design moments will be magnified.

NSECTION 12 Number of equally-spaced sections to be considered in finding critical moments for beam design.

WIDTH ZD Width of the concrete member. This value defaults to ZD as provided under MEMBER PROPERTIES.

DEPTH YD Depth of the concrete member. This value defaults to YD as provided under MEMBER PROPERTIES.

3A.6 Beam Design

Beams are designed for flexure, shear and torsion. For all these forces, all active beam loadings are scanned to create moment and shear envelopes, and locate critical sections. The total number of sections considered is thirteen (start, end and 11 intermediate), unless that number is redefined with the NSECTION parameter. Design for Flexure

Design for flexure is performed per the rules of Chapter 2 of CSA Standard A23.3-94. Maximum sagging (creating tensile stress at the bottom face of the beam) and hogging (creating tensile stress at the top face) moments are calculated for all active load cases at each of the thirteen sections. Each of these sections are designed

Page 163: International Design Codes

Section 3A 3-5

to resist the critical sagging and hogging moments. Currently, design of singly reinforced sections only is permitted. If the section dimensions are inadequate as a singly reinforced section, such a message will be printed in the output. Flexural design of beams is performed in two passes. In the first pass, effective depths of the sections are determined with the assumption of single layer of assumed reinforcement and reinforcement requirements are calculated. After the preliminary design, reinforcing bars are chosen from the internal database in single or multiple layers. The entire flexure design is performed again in a second pass taking into account the changed effective depths of sections calculated on the basis of reinforcement provided after the preliminary design. Final provision of flexural reinforcements are made then. Efforts have been made to meet the guideline for the curtailment of reinforcements as per CSA Standard A23.3-94. Although exact curtailment lengths are not mentioned explicitly in the design output (which finally will be more or less guided by the detailer taking into account other practical considerations), the user has the choice of printing reinforcements provided by STAAD at 13 equally spaced sections from which the final detailed drawing can be prepared. The following annotations apply to the output for Beam Design. 1) LEVEL - Serial number of bar level which may

contain one or more bar group. 2) HEIGHT - Height of bar level from the bottom of

beam. 3) BAR INFOrmation - Reinforcement bar information

specifying number of bars and size. 4) FROM - Distance from the start of the beam to

the start of the rebar. 5) TO - Distance from the start of the beam to

the end of the rebar.

Page 164: International Design Codes

Concrete Design Per CSA Standard A23.3-94

Section 3A 3-6 6) ANCHOR - States whether anchorage, either a hook (STA,END) or continuation, is needed at start (STA)

or at the end (END) of the bar.

Design for Shear and Torsion

Design for shear and torsion is performed per the rules of Chapter 4 of CSA Standard A23.3-94. Shear reinforcement is calculated to resist both shear forces and torsional moments. Shear design is performed at the start and end sections. The location along the member span for design is chosen as the effective depth + SFACE at the start, and effective depth + EFACE at the end. The load case which gives rise to the highest stirrup area for shear & torsion is chosen as the critical one. The calculations are performed assuming 2-legged stirrups will be provided. The additional longitudinal steel area required for torsion is reported. The stirrups are assumed to be U-shaped for beams with no torsion, and closed hoops for beams subjected to torsion.

Example of Input Data for Beam Design UNIT NEWTON MMS START CONCRETE DESIGN CODE CANADA FYMAIN 415 ALL FYSEC 415 ALL FC 35 ALL CLEAR 25 MEMB 2 TO 6 MAXMAIN 40 MEMB 2 TO 6 TRACK 1.0 MEMB 2 TO 9 DESIGN BEAM 2 TO 9 END CONCRETE DESIGN

Page 165: International Design Codes

Section 3A 3-7

3A.7 Column Design

Column design is performed per the rules of Chapters 7 & 8 of the CSA Standard A23.3-94. Columns are designed for axial force and biaxial moments at the ends. All active loadings are tested to calculate reinforcement. The loading which produces maximum reinforcement is called the critical load. Column design is done for square, rectangular and circular sections. For rectangular and square sections, the reinforcement is always assumed to be equally distributed on each side. That means the total number of bars will always be a multiple of four (4). This may cause slightly conservative results in some cases.

Example of Input Data for Column Design UNIT NEWTON MMS START CONCRETE DESIGN CODE CANADIAN FYMAIN 415 ALL FC 35 ALL CLEAR 25 MEMB 2 TO 6 MAXMAIN 40 MEMB 2 TO 6 DESIGN COLUMN 2 TO 6 END CONCRETE DESIGN

3A.8 Slab/Wall Design

To design a slab or wall, it must be modeled using finite elements. The commands for specifying elements are in accordance with the relevant sections of the Technical Reference Manual. Elements are designed for the moments Mx and My using the same principles as those for beams in flexure. The width of the beam is assumed to be unity for this purpose. These moments are obtained from the element force output (see the relevant sections of the

Page 166: International Design Codes

Concrete Design Per CSA Standard A23.3-94

Section 3A 3-8 Technical Reference Manual). The reinforcement required to resist Mx moment is denoted as longitudinal reinforcement and the reinforcement required to resist My moment is denoted as transverse reinforcement. The effective depth is calculated assuming #10 bars are provided. The parameters FYMAIN, FC, CLT and CLB listed in Table 3A.1 are relevant to slab design. Other parameters mentioned in Table 3A.1 are not applicable to slab design. The output consists only of area of steel required. Actual bar arrangement is not calculated because an element most likely represents just a fraction of the total slab area.

LONG.

TRANS.

X

Y

Z

M

MM

M x

y

x

y

Example of Input Data for Slab/Wall Design UNIT NEWTON MMS START CONCRETE DESIGN CODE CANADA FYMAIN 415 ALL FC 35 ALL CLB 40 ALL DESIGN ELEMENT 15 TO 20 END CONCRETE DESIGN

Page 167: International Design Codes

3-9

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B

3B.1 General Comments

The design of structural steel members in accordance with the specification CAN/CSA S16-01 Limit States Design of Steel Structures is now implemented. This code supercedes the previous edition of the code CAN/CSA – S16.1-94. The design philosophy embodied in this specification is based on the concept of limit state design. Structures are designed and proportioned taking into consideration the limit states at which they would become unfit for their intended use. Two major categories of limit-state are recognized - ultimate and serviceability. The primary considerations in ultimate limit state design are strength and stability, while that in serviceability is deflection. Appropriate load and resistance factors are used so that a uniform reliability is achieved for all steel structures under various loading conditions and at the same time the chances of limits being surpassed are acceptably remote. In the STAAD implementation, members are proportioned to resist the design loads without exceeding the limit states of strength, stability and serviceability. Accordingly, the most economic section is selected on the basis of the least weight criteria as augmented by the designer in specification of allowable member depths, desired section type, or other such parameters. The code checking portion of the program checks whether code requirements for each selected section are met and identifies the governing criteria.

Page 168: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-10 The following sections describe the salient features of the STAAD implementation of CAN/CSA-S16-01. A detailed description of the design process along with its underlying concepts and assumptions is available in the specification document.

3B.2 Analysis Methodology

Elastic analysis method is used to obtain the forces and moments for design. Analysis is done for the primary and combination loading conditions provided by the user. The user is allowed complete flexibility in providing loading specifications and using appropriate load factors to create necessary loading situations. Depending upon the analysis requirements, regular stiffness analysis or P-Delta analysis may be specified. Dynamic analysis may also be performed and the results combined with static analysis results.

3B.3 Member Property Specifications

For specification of member properties, the steel section library available in STAAD may be used. The next section describes the syntax of commands used to assign properties from the built-in steel table. Member properties may also be specified using the User Table facility. For more information on these facilities, refer to the STAAD Technical Reference Manual.

3B.4 Built-in Steel Section Library

The following information is provided for use when the built-in steel tables are to be referenced for member property specification. These properties are stored in a database file. If called for, the properties are also used for member design. Since the shear areas are built into these tables, shear deformation is always considered during the analysis of these members.

Page 169: International Design Codes

Section 3B 3-11

Almost all Canadian steel sections are available for input. A complete listing of the sections available in the built-in steel section library may be obtained by using the tools of the graphical user interface. Following is the description of the different types of sections available: Welded Wide Flanges (WW shapes)

Welded wide flange shapes listed in the CSA steel tables can be designated using the same scheme used by CSA. The following example illustrates the specification of welded wide flange shapes.

100 TO 150 TA ST WW400X444 34 35 TA ST WW900X347

Wide Flanges (W shapes)

Designation of wide flanges in STAAD is the same as that in CSA tables. For example,

10 TO 75 95 TO 105 TA ST W460X106 100 TO 200 TA ST W610X101

S, M, HP shapes

In addition to welded wide flanges and regular wide flanges, other I shaped sections like S, M and HP shapes are also available. The designation scheme is identical to that listed in the CSA tables. While specifying the sections, it should be remembered that the portion after the decimal point should be omitted. Thus, M310X17.6 should be specified as M310X17 and S180X22.8 should be specified as S180X22. Examples illustrating specifications of these shapes are provided below.

Page 170: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-12

10 TO 20 BY 2 TA ST S510X98 45 TO 55 TA ST M150X6 88 90 96 TA ST HP310X79

Channel Sections (C & MC shapes)

C and MC shapes are designated as shown in the following example. As in S, M and HP sections, the portion after the decimal point must be omitted in section designations. Thus, MC250X42.4 should be designated as MC250X42.

55 TO 90 TA ST C250X30 30 TO 45 TA ST MC200X33

Double Channels

Back to back double channels, with or without spacing between them, are specified by preceding the section designation by the letter D. For example, a back to back double channel section C200X28 without any spacing in between should be specified as:

100 TO 120 TA D C200X28

If a spacing of 2.5 length units is used, the specification should be as follows:

100 TO 120 TA D C200X28 SP 2.5

Note that the specification SP after the section designation is used for providing the spacing. The spacing should always be provided in the current length unit.

Page 171: International Design Codes

Section 3B 3-13

Angles To specify angles, the angle name is preceded by the letter L. Thus, a 200X200 angle with a 25mm thickness is designated as L200X200X25. The following examples illustrate angle specifications.

75 TO 95 TA ST L100X100X8 33 34 35 TA ST L200X100X20

Note that the above specification is for “standard” angles. In this specification, the local z-axis (see Fig. 2.6 in the Technical Reference Manual) corresponds to the Y’-Y’ axis shown in the CSA table. Another common practice of specifying angles assumes the local y-axis to correspond to the Y’-Y’ axis. To specify angles in accordance with this convention, the reverse angle designation facility has been provided. A reverse angle may be specified by substituting the word ST with the word RA. Refer to the following example for details.

10 TO 15 TA RA L55X35X4

The local axis systems for STANDARD and REVERSE angles is shown in Fig. 2.6 of the STAAD Technical Reference manual. Double AnglesTo specify double angles, the specification ST should be substituted with LD (for long leg back to back) or SD (short leg back to back). For equal angles, either SD or LD will serve the purpose. Spacing between angles may be provided by using the word SP followed by the value of spacing (in current length unit) after section designation.

25 35 45 TA LD L150X100X16 80 TO 90 TA SD L125X75X6 SP 2.5

Page 172: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-14 The second example above describes a double angle section consisting of 125X75X6 angles with a spacing of 2.5 length units. Tees

Tee sections obtained by cutting W sections may be specified by using the T specification instead of ST before the name of the W shape. For example:

100 TO 120 TA T W200X42

will describe a T section cut from a W200X42 section. Rectangular Hollow Sections

These sections may be specified in two possible ways. Those sections listed in the CSA tables may be specified as follows.

55 TO 75 TA ST TUB80X60X4

Tube Symbol Thickness (in) X16

Width (in.) X10

TUB 80 X 60 X 4

Height (in) X 10 In addition, any tube section may be specified by using the DT(for depth), WT(for width), and TH(for thickness) specifications.

Page 173: International Design Codes

Section 3B 3-15

For example:

100 TO 200 TA ST TUBE DT 8.0 WT 6.0 TH 0.5

will describe a tube with a depth of 8 in., width of 6 in. and a wall thickness of 0.5 inches. Note that the values of depth, width and thickness must be provided in current length unit. Circular Hollow Sections

Sections listed in the CSA tables may be provided as follows:

15 TO 25 TA ST PIP33X2.5

Pipe Symbol Thickness (mm)

Diameter (mm)

PIP 33 X 2.5

(Upto first decimal place only)

without decimal point In addition to sections listed in the CSA tables, circular hollow sections may be specified by using the OD (outside diameter) and ID (inside diameter) specifications. For example:

70 TO 90 TA ST PIPE OD 10.0 ID 9.0

will describe a pipe with an outside diameter of 10 length units and inside diameter of 9.0 length units. Note that the values of outside and inside diameters must be provided in terms of current length unit.

Page 174: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-16

Sample input file to demonstrate usage of Canadian shapes STAAD SPACE UNIT METER KNS JOINT COORD 1 0 0 0 17 160 0 0 MEMBER INCIDENCES 1 1 2 16 UNIT CM MEMBER PROPERTIES CANADIAN * W SHAPES 1 TA ST W250X18 * WW SHAPES 2 TA ST WW700X185 * S SHAPES 3 TA ST S200X27 * M SHAPES 4 TA ST M130X28 * HP SHAPES 5 TA ST HP310X132 * MC CHANNELS 6 TA ST MC150X17 * C CHANNELS 7 TA ST C180X18 * DOUBLE CHANNELS 8 TA D C250X37 SP 1.0 * ANGLES 9 TA ST L55X35X5 * REVERSE ANGLES 10 TA RA L90X75X5 * DOUBLE ANGLES, LONG LEG BACK TO BACK 11 TA LD L100X90X6 SP 2.0 * DOUBLE ANGLES, SHORT LEG BACK TO BACK 12 TA SD L125X75X6 SP 2.5 * TUBES 13 TA ST TUB120807

Page 175: International Design Codes

Section 3B 3-17

* TUBES 14 TA ST TUBE DT 16.0 WT 8.0 TH 0.8 * PIPES 15 TA ST PIP273X6.3 * PIPES 16 TA ST PIPE OD 16.0 ID 13.0 PRINT MEMBER PROPERTIES FINISH

3B.5 Section Classification

The CSA specification allows inelastic deformation of section elements. Thus, local buckling becomes an important criterion. Steel sections are classified as plastic (Class 1), compact (Class 2), non compact (Class 3) or slender element (Class 4) sections depending upon their local buckling characteristics (See Clause 11.2 and Table 1 of CAN/CSA-S16-01). This classification is a function of the geometric properties of the section. The design procedures are different depending on the section class. STAAD determines the section classification for the standard shapes and user specified shapes. Design is performed for sections that fall into the category of Class 1,2 or 3 sections only. Class 4 sections are not designed by STAAD.

3B.6 Member Resistances

The member resistances are calculated in STAAD according to the procedures outlined in section 13 of the specification. These depend on several factors such as members unsupported lengths, cross-sectional properties, slenderness factors, unsupported width to thickness ratios and so on. Note that the program automatically takes into consideration appropriate resistance factors to calculate member resistances. Explained here is the procedure adopted in STAAD for calculating the member resistances.

Page 176: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-18 Axial Tension The criteria governing the capacity of tension members is based on two limit states. The limit state of yielding in the gross section is intended to prevent excessive elongation of the member. The second limit state involves fracture at the section with the minimum effective net area. The net section area may be specified by the user through the use of the parameter NSF (see Table 3B.1). STAAD calculates the tension capacity of a member based on these two limits states per Cl.13.2 of CAN/CSA-S16-01. Parameters FYLD, FU and NSF are applicable for these calculations. Axial Compression

The compressive resistance of columns is determined based on Clause 13.3 of the code. The equations presented in this section of the code assume that the compressive resistance is a function of the compressive strength of the gross section (Gross section Area times the Yield Strength) as well as the slenderness factor (KL/r ratios). The effective length for the calculation of compression resistance may be provided through the use of the parameters KX, KY, KZ, LX, LY and LZ (see Table 3B.1). Some of the aspects of the axial compression capacity calculations are : 1) For frame members not subjected to any bending, and for truss

members, the axial compression capacity in general column flexural buckling is calculated from Cl.13.3.1 using the slenderness ratios for the local Y-Y and Z-Z axis. The parameters KY, LY, KZ and LZ are applicable for this.

2) For single angles, which are frame members not subjected to any bending or truss members, the axial compression capacity in general column flexural buckling and local buckling of thin legs is calculated using the rules of the AISC - LRFD code, 2nd ed., 1994. The reason for this is that the Canadian code doesn’t provide any clear guidelines for calculating this value. The parameters KY, LY, KZ and LZ are applicable for this.

3) The axial compression capacity is also calculated by taking flexural-torsional buckling into account. The rules of Appendix D, page 1-109 of CAN/CSA-S16-01are used for this

Page 177: International Design Codes

Section 3B 3-19

purpose. Parameters KX and LX may be used to provide the effective length factor and effective length value for flexural-torsional buckling. Flexural-torsional buckling capacity is computed for single channels, single angles, Tees and Double angles.

4) The variable “n” in Cl.13.3.1 is assumed as 2.24 for WWF shapes and 1.34 for all other shapes.

5) While computing the general column flexural buckling capacity of sections with axial compression + bending, the special provisions of 13.8.1(a), 13.8.1(b) and 13.8.1(c) are applied. For example, Lambda = 0 for 13.8.1(a), K=1 for 13.8.1(b), etc.)

Bending

The laterally unsupported length of the compression flange for the purpose of computing the factored moment resistance is specified in STAAD with the help of the parameter UNL. If UNL is less than one tenth the member length (member length is the distance between the joints of the member), the member is treated as being continuously laterally supported. In this case, the moment resistance is computed from Clause 13.5 of the code. If UNL is greater than or equal to one tenth the member length, its value is used as the laterally unsupported length. The equations of Clause 13.6 of the code are used to arrive at the moment of resistance of laterally unsupported members. Some of the aspects of the bending capacity calculations are : 1) The weak axis bending capacity of all sections except single

angles is calculated as

For Class 1 & 2 sections, Phi*Py*Fy For Class 3 sections, Phi*Sy*Fy where Phi = Resistance factor = 0.9 Py = Plastic section modulus about the local Y axis Sy = Elastic section modulus about the local Y axis Fy = Yield stress of steel

Page 178: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-20 2) For single angles, the bending capacities are calculated for the

principal axes. The specifications of Section 5, page 6-283 of AISC-LRFD 1994, 2nd ed., are used for this purpose because the Canadian code doesn’t provide any clear guidelines for calculating this value.

3) For calculating the bending capacity about the Z-Z axis of singly symmetric shapes such as Tees and Double angles, CAN/CSA-S16-01 stipulates in Clause 13.6(d), page 1-31, that a rational method, such as that given in SSRC’s Guide to Stability Design Criteria of Metal Structures, be used. Instead, STAAD uses the rules of Section 2c, page 6-55 of AISC-LRFD 1994, 2nd ed.

Axial compression and bending

The member strength for sections subjected to axial compression and uniaxial or biaxial bending is obtained through the use of interaction equations. In these equations, the additional bending caused by the action of the axial load is accounted for by using amplification factors. Clause 13.8 of the code provides the equations for this purpose. If the summation of the left hand side of these equations exceed 1.0 or the allowable value provided using the RATIO parameter (see Table 3B.1), the member is considered to have FAILed under the loading condition. Axial tension and bending

Members subjected to axial tension and bending are also designed using interaction equations. Clause 13.9 of the code is used to perform these checks. The actual RATIO is determined as the value of the left hand side of the critical equation. Shear

The shear resistance of the cross section is determined using the equations of Clause 13.4 of the code. Once this is obtained, the ratio of the shear force acting on the cross section to the shear resistance of the section is calculated. If any of the ratios (for both local Y & Z axes) exceed 1.0 or the allowable value provided using the RATIO parameter (see Table 3B.1), the section is

Page 179: International Design Codes

Section 3B 3-21

considered to have failed under shear. The code also requires that the slenderness ratio of the web be within a certain limit (See Cl.13.4.1.3, page 1-29 of CAN/CSA-S16-01). Checks for safety in shear are performed only if this value is within the allowable limit. Users may by-pass this limitation by specifying a value of 2.0 for the MAIN parameter.

3B.7 Design Parameters

The design parameters outlined in Table 3B.1 may be used to control the design procedure. These parameters communicate design decisions from the engineer to the program and thus allows the engineer to control the design process to suit an application's specific needs. The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements, some or all of these parameter values may be changed to exactly model the physical structure.

Canadian Steel Design Parameters

Parameter Default Description Name Value

KT 1.0 K value for flexural torsional buckling.

KY 1.0 K value for general column flexural buckling about the local Y-axis. Used to calculate slenderness ratio.

KZ 1.0 K value for general column flexural buckling about the local Z-axis. Used to calculate slenderness ratio.

LT Member Length Length for flexural torsional buckling.

LY Member Length Length for general column flexural buckling about the local Y-axis. Used to calculate slenderness ratio.

LZ Member Length Length for general column flexural buckling about the local Z-axis. Used to calculate slenderness ratio.

Page 180: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-22

Canadian Steel Design Parameters

Parameter Default Description Name Value

FYLD 300.0 MPa Yield strength of steel.

FU 345.0 MPa Ultimate strength of steel.

NSF 1.0 Net section factor for tension members.

UNT Member Length Unsupported length in bending compression of the top flange for calculating moment resistance.

UNB Member Length Unsupported length in bending compression of the bottom flange for calculating moment resistance.

MAIN 0.0 0.0 = Check slenderness ratio against the limits. 1.1 = Suppress the slenderness ratio check.

2.0 = Check slenderness ratio only for column buckling, not for web (See Section 3B.6, Shear)

CB 1.0 Greater than 0.0 and less than 2.5 : Value of Omega_2 (Cl.13.6) to be used for calculation.

Equal to 0.0 : Calculate Omega_2

SSY 0.0 0.0 = Frame subjected to sidesway about local Y axis.

1.0 = Frame not subjected to sidesway about local Y axis.

Used in calculating Omega_2, Cl.13.6 of code

SSZ 0.0 0.0 = Frame subjected to sidesway about local Z axis.

1.0 = Frame not subjected to sidesway about local Z axis.

Used in calculating Omega_2, Cl.13.6 of code

CMY 1.0 1.0 = Do not calculate Omega-1 for local Y axis. 2.0 = Calculate Omega-1 for local Y axis. Used in Cl.13.8.4 of code

CMZ 1.0 1.0 = Do not calculate Omega-1 for local Z axis. 2.0 = Calculate Omega-1 for local Z axis. Used in Cl.13.8.4 of code

TRACK 0.0 0.0 = Report only minimum design results.

1.0 = Report design strengths also.

2.0 = Provide full details of design.

Page 181: International Design Codes

Section 3B 3-23

Canadian Steel Design Parameters

Parameter Default Description Name Value

DMAX 45.0 in. Maximum allowable depth (Applicable for member selection)

DMIN 0.0 in. Minimum required depth (Applicable for member selection)

RATIO 1.0 Permissible ratio of actual load effect to the design strength.

BEAM 0.0 0.0 = design only for end moments and those at locations specified by SECTION command.

1.0 = Perform design for moments at twelfth points along the beam.

DFF None(Mandatory for deflection

check)

“Deflection Length”/Maxm. Allowable local deflection.

DJ1 Start Joint of member

Joint No. denoting start point for calculation of “deflection length”

DJ2 End Joint of member

Joint No. denoting end point for calculation of “deflection length”

3B.8 Code Checking

The purpose of code checking is to check whether the provided section properties of the members are adequate. The adequacy is checked as per the CAN/CSA-S16-01 requirements. Code checking is done using forces and moments at specified sections of the members. If the BEAM parameter for a member is set to 1, moments are calculated at every twelfth point along the beam. When no sections are specified and the BEAM parameter is set to zero (default), design will be based on member start and end forces only. The code checking output labels the members as PASSed or FAILed. In addition, the critical condition, governing load case, location (distance from the start joint) and magnitudes of the governing forces and moments are also printed. The extent

Page 182: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-24 of detail of the output can be controlled by using the TRACK parameter. Example of commands for CODE CHECKING:

UNIT NEWTON METER PARAMETER FYLD 330E6 MEMB 3 4 NSF 0.85 ALL KY 1.2 MEMB 3 4 UNL 15 MEMB 3 4 RATIO 0.9 ALL CHECK CODE MEMB 3 4

3B.9 Member Selection

The member selection process basically involves determination of the least weight member that PASSes the code checking procedure based on the forces and moments of the most recent analysis. The section selected will be of the same type as that specified initially. For example, a member specified initially as a channel will have a channel selected for it. Selection of members whose properties are originally provided from a user table will be limited to sections in the user table. Member selection cannot be performed on TUBES, PIPES or members listed as PRISMATIC.

Page 183: International Design Codes

Section 3B 3-25

Example of commands for MEMBER SELECTION:

UNIT NEWTON METER PARAMETER FYLD 330E6 MEMB 3 4 NSF 0.85 ALL KY 1.2 MEMB 3 4 UNL 15 MEMB 3 4 RATIO 0.9 ALL SELECT MEMB 3 4

3B.10 Tabulated Results of Steel Design

Results of code checking and member selection are presented in a tabular format. The term CRITICAL COND refers to the section of the CAN/CSA-S16-01 specification which governed the design. If the TRACK parameter is set to 1.0, factored member resistances will be printed. Following is a description of some of the items printed. CR = Factored compressive resistance TR = Factored tensile resistance VR = Factored shear resistance MRZ = Factored moment resistance (about z-axis) MRY = Factored moment resistance (about y-axis)

Further details can be obtained by setting TRACK to 2.0.

Page 184: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-26

3B.11 Verification Problems

In the next few pages are included 3 verification examples for reference purposes. Since the S16-01 code is similar in many respects to the previous edition of the code (CAN/CSA S16.1-94), the solved examples of the 1994 edition of the CISC Handbook have been used as reference material for these examples.

Page 185: International Design Codes

Section 3B 3-27

Verification Problem No. 1

TITLE Steel beam with uniform load, wide flange section. TYPE Static analysis, 3D beam element. REFERENCE: CAN/CSA-S16.1-94, National Standard of Canada,

Limit States Design of Steel Structures. The Canadian Standards Association, 1994 with CISC (Canadian Institute of Steel Construction) handbook. CISC Example 1 page 5_91.

PROBLEM: Find the interaction ratio, beam resistance and beam

deflection.

GIVEN:

s 1.0, Kz 1.0, unsupported

Load deflection, L/300 = 8000/300 = 27 mm Factored Uniform Load IS 7 kN/m DEAD, 15 kN/m LIVE. Steel section is W41

SOLUTION COMPARISON:

CA 6

E = 200000 MPa (STEEL). F = 300 Mpa CSA G40.21-M yBeam has a 8.0 m span; Ky ilength 1.0 m Allowable Live

0X54.

N/CSA-S1

Int n B Resistance

(kN*m)

B Deflection

(mm)

eractio

Ratio

eam eam

REFERENCE 0.88 284 21

STAAD.Pro 0.883 283.20 20.81

Page 186: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-28

**************************************************** * * * STAAD.Pro * * Version Bld * * Proprietary Program of * * Research Engineers, Intl. * * Date= * * Time= * * * * USER ID: * **************************************************** 1. STAAD SPACE VERIFICATION CISC 1994 HANDBOOK EXAMPLE PAGE 5-91 3. * CISC EXAMPLE 1 PAGE 5-91, LIMIT STATES DESIGN, CSA-S16.1-94 4. * SIMPLY SUPPORTED BEAM WITH UNIFORM LOAD 5. * LIVE LOAD DEFLECTION OF L/300 7. UNIT MMS KN 8. JOINT COORDINATES 9. 1 0 0 0; 2 8000 0 0 10. MEMBER INCIDENCES 11. 1 1 2 13. MEMBER PROPERTY CANADIAN 14. 1 TABLE ST W410X54 16. CONSTANTS 17. E STEEL ALL 18. POISSON 0.3 ALL 20. SUPPORTS 21. 1 PINNED 22. 2 FIXED BUT MY MZ 24. UNIT METER KN 25. LOAD 1 DEAD 26. MEMBER LOAD 27. 1 UNI GY -7 29. LOAD 2 LIVE 30. MEMBER LOAD 31. 1 UNI GY -15 33. LOAD COMB 3 1.25DL + 1.5 LL 34. 1 1.25 2 1.5 36. PERFORM ANALYSIS P R O B L E M S T A T I S T I C S ----------------------------------- NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 2/ 1/ 2 ORIGINAL/FINAL BAND-WIDTH= 1/ 1/ 5 DOF TOTAL PRIMARY LOAD CASES = 2, TOTAL DEGREES OF FREEDOM = 5 SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS REQRD/AVAIL. DISK SPACE = 12.0/ 19641.6 MB 37. LOAD LIST 2

Page 187: International Design Codes

Section 3B 3-29

38. PRINT SECTION DISPLACEMENTS MEMBER SECTION DISPLACEMENTS ---------------------------- UNIT =INCHES FOR FPS AND CM FOR METRICS/SI SYSTEM MEMB LOAD GLOBAL X,Y,Z DISPL FROM START TO END JOINTS AT 1/12TH PTS 1 2 0.0000 0.0000 0.0000 0.0000 -0.5471 0.0000 0.0000 -1.0528 0.0000 0.0000 -1.4824 0.0000 0.0000 -1.8086 0.0000 0.0000 -2.0120 0.0000 0.0000 -2.0812 0.0000 0.0000 -2.0120 0.0000 0.0000 -1.8086 0.0000 0.0000 -1.4824 0.0000 0.0000 -1.0528 0.0000 0.0000 -0.5471 0.0000 0.0000 0.0000 0.0000 MAX LOCAL DISP = 2.08115 AT 400.00 LOAD 2 L/DISP= 384 ************ END OF SECT DISPL RESULTS *********** 40. LOAD LIST 3 41. PARAMETER 42. CODE CANADIAN 43. TRACK 2 ALL 44. UNL 1 ALL 45. FYLD 300000 ALL 46. BEAM 1 ALL 47. CHECK CODE ALL STAAD.PRO CODE CHECKING - (CAN/CSA-S16-01) ****************************************** ALL UNITS ARE - KNS MET (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 1 ST W410X54 (CANADIAN SECTIONS) PASS CSA-13.8.2+ 0.883 3 0.00 C 0.00 -250.00 4.00 MEMBER PROPERTIES (UNIT = CM) ----------------------------- CROSS SECTION AREA = 6.84E+01 MEMBER LENGTH = 8.00E+02 IZ = 1.86E+04 SZ = 9.26E+02 PZ = 1.05E+03 IY = 1.02E+03 SY = 1.15E+02 PY = 1.77E+02 MATERIAL PROPERTIES (UNIT = MPA) -------------------------------- FYLD = 300.0 FU = 345.0 SECTION CAPACITIES (UNIT - KN,M) --------------------------------- CR1 = 1.846E+03 CR2 = 2.732E+02 CRZ = 1.570E+03 CTORFLX = 2.732E+02 TENSILE CAPACITY = 1.805E+03 COMPRESSIVE CAPACITY = 2.732E+02 FACTORED MOMENT RESISTANCE : MRY = 4.778E+01 MRZ = 2.832E+02 FACTORED SHEAR RESISTANCE : VRY = 5.379E+02 VRZ = 4.604E+02

Page 188: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-30

MISCELLANEOUS INFORMATION -------------------------- NET SECTION FACTOR FOR TENSION = 1.000 KL/RY = 207.170 KL/RZ = 48.447 ALLOWABLE KL/R = 300.000 UNSUPPORTED LENGTH OF THE COMPRESSION FLANGE (M) = 1.000 OMEGA-1 (Y-AXIS) = 1.00 OMEGA-1 (Z-AXIS) = 1.00 OMEGA-2 = 1.00 SHEAR FORCE (KNS) : Y AXIS = 0.000E+00 Z AXIS = 0.000E+00 SLENDERNESS RATIO OF WEB (H/W) = 5.08E+01 48. STEEL TAKE OFF ALL STEEL TAKE-OFF -------------- PROFILE LENGTH(METE) WEIGHT(KN ) In Steel Takeoff the density of steel is assumed for members with no density. ST W410X54 8.00 4.203 PRISMATIC STEEL 0.00 0.000 ---------------- TOTAL = 4.203 ************ END OF DATA FROM INTERNAL STORAGE ************ 49. FINISH

Page 189: International Design Codes

Section 3B 3-31

Verification Problem No. 2

TITLE: Steel beam/column, wide flange section. TYPE: Static Analysis, 3D beam element. REFERENCE: CAN/CSA-S16.1-94, National Standard of Canada,

Limit States Design of Steel Structures. The Canadian Standards Association, 1994 with CISC (Canadian Institute of Steel Construction) handbook. CISC Handbook Example, Page 4_106.

PROBLEM: Find the interaction ratio, beam and column resistance.

Page 190: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-32 GIVEN: E = 200000 MPa (STEEL).

Fy = 300 MPa CSA G40.21-M Beam/Column has a 3.7 m span, Ky is 1.0, Kz 1.0 factored axial load is 2000 kN and end moments of 200 kN*m and 300 kN*m Steel section is W310X129

SOLUTION COMPARISON:

CAN/CSA-S16

Interaction

Ratio

Beam Resistance

(kN*m)

Column Resistance

(kN)

REFERENCE 0.96 583 3800

STAAD.Pro 0.98 584 3820

Page 191: International Design Codes

Section 3B 3-33

**************************************************** * * * STAAD.Pro * * Version Bld * * Proprietary Program of * * Research Engineers, Intl. * * Date= * * Time= * * * * USER ID: * **************************************************** 1. STAAD SPACE VERIFICATION CISC 1994 HANDBOOK EXAMPLE PAGE 4-106 2. * 3. * COMPRESSION + MAJOR AXIS BENDING 4. * 5. UNIT METER KN 6. JOINT COORDINATES 7. 1 0 0 0; 2 0 3.7 0 8. * 9. MEMBER INCIDENCES 10. 1 1 2 11. * 12. MEMBER PROPERTY CANADIAN 13. 1 TABLE ST W310X129 14. * 15. CONSTANTS 16. E STEEL ALL 17. POISSON STEEL ALL 18. * 19. SUPPORTS 20. 1 FIXED BUT MX MZ 21. 2 FIXED BUT FY MY MZ 22. * 23. LOAD 1 FACTORED LOAD 24. JOINT LOAD 25. 2 FY -2000 26. 2 MZ 200 27. 1 MZ 300 28. * 29. PDELTA 3 ANALYSIS P R O B L E M S T A T I S T I C S ----------------------------------- NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 2/ 1/ 2 ORIGINAL/FINAL BAND-WIDTH= 1/ 1/ 5 DOF TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 5 SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS REQRD/AVAIL. DISK SPACE = 12.0/ 19641.2 MB ++ Adjusting Displacements 8:54:35 ++ Adjusting Displacements 8:54:35 ++ Adjusting Displacements 8:54:35

Page 192: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-34

31. PRINT MEMBER FORCES MEMBER END FORCES STRUCTURE TYPE = SPACE ----------------- ALL UNITS ARE -- KN METE MEMBER LOAD JT AXIAL SHEAR-Y SHEAR-Z TORSION MOM-Y MOM-Z 1 1 1 2000.00 135.14 0.00 0.00 0.00 300.00 2 -2000.00 -135.14 0.00 0.00 0.00 200.00 ************** END OF LATEST ANALYSIS RESULT ************** 33. PARAMETER 34. CODE CANADIAN 35. TRACK 2 ALL 36. FYLD 300000 ALL 37. LY 3.7 ALL 38. LZ 3.7 ALL 39. CHECK CODE ALL STAAD.PRO CODE CHECKING - (CAN/CSA-S16-01) ****************************************** ALL UNITS ARE - KNS MET (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 1 ST W310X129 (CANADIAN SECTIONS) PASS CSA-13.8.2C 0.980 1 2000.00 C 0.00 300.00 0.00 MEMBER PROPERTIES (UNIT = CM) ----------------------------- CROSS SECTION AREA = 1.65E+02 MEMBER LENGTH = 3.70E+02 IZ = 3.08E+04 SZ = 1.94E+03 PZ = 2.16E+03 IY = 1.00E+04 SY = 6.51E+02 PY = 9.90E+02 MATERIAL PROPERTIES (UNIT = MPA) -------------------------------- FYLD = 300.0 FU = 345.0 SECTION CAPACITIES (UNIT - KN,M) --------------------------------- CR1 = 4.459E+03 CR2 = 3.820E+03 CRZ = 4.296E+03 CTORFLX = 3.820E+03 TENSILE CAPACITY = 4.359E+03 COMPRESSIVE CAPACITY = 3.820E+03 FACTORED MOMENT RESISTANCE : MRY = 2.672E+02 MRZ = 5.840E+02 FACTORED SHEAR RESISTANCE : VRY = 7.419E+02 VRZ = 1.505E+03

Page 193: International Design Codes

Section 3B 3-35

MISCELLANEOUS INFORMATION -------------------------- NET SECTION FACTOR FOR TENSION = 1.000 KL/RY = 47.477 KL/RZ = 27.094 ALLOWABLE KL/R = 200.000 UNSUPPORTED LENGTH OF THE COMPRESSION FLANGE (M) = 3.700 OMEGA-1 (Y-AXIS) = 1.00 OMEGA-1 (Z-AXIS) = 1.00 OMEGA-2 = 1.00 SHEAR FORCE (KNS) : Y AXIS = 1.351E+02 Z AXIS = 0.000E+00 SLENDERNESS RATIO OF WEB (H/W) = 2.12E+01 40. STEEL MEMBER TAKE OFF ALL STEEL TAKE-OFF -------------- PROFILE LENGTH(METE) WEIGHT(KN ) In Steel Takeoff the density of steel is assumed for members with no density. ST W310X129 3.70 4.694 PRISMATIC STEEL 0.00 0.000 ---------------- TOTAL = 4.694 MEMBER PROFILE LENGTH WEIGHT (METE) (KN ) 1 ST W310X129 3.70 4.694 ************ END OF DATA FROM INTERNAL STORAGE ************ 42. FINISH

Page 194: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-36

Verification Problem No. 3

TITLE: Steel beam/column, wide flange section.

TYPE: Static Analysis, 3D beam element.

REFERENCE: CAN/CSA-S16.1-94, National Standard of Canada, Limit States Design of Steel Structures. The Canadian Standards Association, 1994 with CISC (Canadian Institute of Steel Construction) handbook. CISC Handbook Example, Page 4_108.

P

ROBLEM: Find the interaction ratio, beam and column resistance.

Page 195: International Design Codes

Section 3B 3-37

GIVEN: E = 200000 MPa (STEEL). Fy = 300 MPa CSA G40.21-M Beam/Column has a 3.7 m span, Ky is 1.0, Kz 1.0, Lu = 3.7 m factored axial load is 2000 kN and end moments of 200 kN*m and 300 kN*m in the strong axis and 100 kN*m at each end in the weak axis. Steel section is W310X143.

SOLUTION COMPARISON:

CAN/CSA-S16

Interaction

Ratio

Beam Resistance

(kN*m)

weak strong

Column Resistance

(kN)

REFERENCE 0.998 300 653 4200

STAAD.Pro 1.00 299 650 4222

Page 196: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-38

**************************************************** * * * STAAD.Pro * * Version Bld * * Proprietary Program of * * Research Engineers, Intl. * * Date= * * Time= * * * * USER ID: * **************************************************** 1. STAAD SPACE VERIFICATION CISC 1994 HANDBOOK EXAMPLE PAGE 4-108 2. * 3. * ( COMPRESSION + BIAXIAL BENDING ) 4. * 5. UNIT METER KN 6. JOINT COORDINATES 7. 1 0 0 0; 2 0 3.7 0 8. * 9. MEMBER INCIDENCES 10. 1 1 2 11. * 12. MEMBER PROPERTY CANADIAN 13. 1 TABLE ST W310X143 14. * 15. CONSTANTS 16. E STEEL ALL 17. POISSON STEEL ALL 18. * 19. SUPPORTS 20. 1 FIXED BUT MX MZ 21. 2 FIXED BUT FY MX MY MZ 22. * 23. LOAD 1 FACTORED LOAD 24. JOINT LOAD 25. 2 FY -2000 26. 2 MZ 200 27. 2 MX 100 28. 1 MZ 300 29. 1 MX 100 30. * 31. PERFORM ANALYSIS P R O B L E M S T A T I S T I C S ----------------------------------- NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 2/ 1/ 2 ORIGINAL/FINAL BAND-WIDTH= 1/ 1/ 6 DOF TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 6 SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS REQRD/AVAIL. DISK SPACE = 12.0/ 19641.2 MB

Page 197: International Design Codes

Section 3B 3-39

33. PARAMETER 34. CODE CANADIAN 35. CMY 2 ALL 36. CMZ 2 ALL 37. CB 1 ALL 38. TRACK 2 ALL 39. FYLD 300000 ALL 40. CHECK CODE ALL STAAD.PRO CODE CHECKING - (CAN/CSA-S16-01) ****************************************** ALL UNITS ARE - KNS MET (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= * 1 ST W310X143 (CANADIAN SECTIONS) FAIL CSA-13.8.2A 1.000 1 2000.00 C -100.00 300.00 0.00 MEMBER PROPERTIES (UNIT = CM) ----------------------------- CROSS SECTION AREA = 1.82E+02 MEMBER LENGTH = 3.70E+02 IZ = 3.47E+04 SZ = 2.15E+03 PZ = 2.41E+03 IY = 1.12E+04 SY = 7.28E+02 PY = 1.11E+03 MATERIAL PROPERTIES (UNIT = MPA) -------------------------------- FYLD = 300.0 FU = 345.0 SECTION CAPACITIES (UNIT - KN,M) --------------------------------- CR1 = 4.912E+03 CR2 = 4.222E+03 CRZ = 4.737E+03 CTORFLX = 4.222E+03 TENSILE CAPACITY = 4.802E+03 COMPRESSIVE CAPACITY = 4.912E+03 FACTORED MOMENT RESISTANCE : MRY = 2.987E+02 MRZ = 6.504E+02 FACTORED SHEAR RESISTANCE : VRY = 8.037E+02 VRZ = 1.678E+03 MISCELLANEOUS INFORMATION -------------------------- NET SECTION FACTOR FOR TENSION = 1.000 KL/RY = 47.077 KL/RZ = 26.802 ALLOWABLE KL/R = 200.000 UNSUPPORTED LENGTH OF THE COMPRESSION FLANGE (M) = 3.700 OMEGA-1 (Y-AXIS) = 0.40 OMEGA-1 (Z-AXIS) = 0.40 OMEGA-2 = 1.00 SHEAR FORCE (KNS) : Y AXIS = 1.351E+02 Z AXIS = 5.405E+01 SLENDERNESS RATIO OF WEB (H/W) = 1.98E+01

Page 198: International Design Codes

Steel Design Per CSA Standard CAN/CSA-S16-01

Section 3B 3-40

41. STEEL MEMBER TAKE OFF ALL STEEL TAKE-OFF -------------- PROFILE LENGTH(METE) WEIGHT(KN ) In Steel Takeoff the density of steel is assumed for members with no density. ST W310X143 3.70 5.171 PRISMATIC STEEL 0.00 0.000 ---------------- TOTAL = 5.171 MEMBER PROFILE LENGTH WEIGHT (METE) (KN ) 1 ST W310X143 3.70 5.171 ************ END OF DATA FROM INTERNAL STORAGE ************ 42. FINISH

Page 199: International Design Codes

3-41

Design Per Canadian Cold Formed Steel Code

Section 3C

3C.1 General

Provisions of CSA S136-94, including revisions dated May, 1995, have been implemented. The program allows design of single (non-composite) members in tension, compression, bending, shear, as well as their combinations. For laterally supported members in bending, the Initiation of Yielding method has been used. Cold work of forming strengthening effects have been included as an option.

3C.2 Cross-Sectional Properties

The user specifies the geometry of the cross-section by selecting one of the section shape designations from the Gross Section Property Tables published in the "Cold-Formed Steel Design Manual", AISI, 1996 Edition. The Tables are currently available for the following shapes:

• Channel with Lips • Channel without Lips • Angle with Lips • Angle without Lips • Z with Lips • Z without Lips • Hat

Page 200: International Design Codes

Design Per Canadian Cold Fomed Steel Code

Section 3C 3-42 Shape selection may be done using the member property pages of the graphical user interface (GUI) or by specifying the section designation symbol in the input file. Details of the latter are available in Section AD.2002.4.1.1 of this document. The properties listed in the tables are gross section properties. STAAD.Pro uses unreduced section properties in the structure analysis stage. Both unreduced and effective section properties are used in the design stage, as applicable.

3C.3 Design Procedure

The following two design modes are available:

1. Code Checking

The program compares the resistance of members with the applied load effects, in accordance with CSA 136. Code checking is carried out for locations specified by the user via the SECTION command or the BEAM parameter. The results are presented in a form of a PASS/FAIL identifier and a RATIO of load effect to resistance for each member checked. The user may choose the degree of detail in the output data by setting the TRACK parameter.

2. Member Selection

The user may request that the program search the cold formed steel shapes database (AISI standard sections) for alternative members that pass the code check and meet the least weight criterion. In addition, a minimum and/or maximum acceptable depth of the member may be specified. The program will then evaluate all database sections of the type initially specified (i.e., channel, angle, etc.) and, if a suitable replacement is found, present design results for that section. If no section satisfying the depth restrictions or lighter than the initial one can be found, the program leaves the member unchanged, regardless of whether it passes the code check or not.

Page 201: International Design Codes

Section 3C 3-43

The program calculates effective section properties in accordance with Clauses 5.6.2.1 through 3 and 5.6.2.6 through 8. Cross-sectional properties and overall slenderness of members are checked for compliance with

• Clause 5.3, Maximum Effective Slenderness Ratio for members in Compression

• Clause 5.4, Maximum Flat Width Ratios for Elements in Compression

• Clause 5.5, Maximum Section Depths. The program will check member strength in accordance with Clause 6 of the Standard as follows:

a. Resistance factors listed in Clauses 6.2 (a), (b), and (e) are used, as applicable.

b. Members in tension Resistance is calculated in accordance with Clauses 6.3.1 and 6.3.2.

c. Members in bending and shear Resistance calculations are based on Clauses: a. 6.4.1 General,

b. 6.4.2 and 6.4.2.1 Laterally Supported Members, compressive limit stress based on Initiation of Yielding,

c. 6.4.3 Laterally Unsupported Members,

d. 6.4.4 Channels and Z-Shaped Members with Unstiffened Flanges - additional limitations,

e. 6.4.5 Shear in Webs,

f. 6.4.6 Combined Bending and Shear in Webs.

Page 202: International Design Codes

Design Per Canadian Cold Fomed Steel Code

Section 3C 3-44

a. Members in compression Resistance calculations are based on Clauses: a. 6.6.1.1, 6.6.1.2 (a) and (d), and 6.6.1.3 General,

b. 6.6.2 Sections Not Subject to Torsional-Flexural Buckling,

c. 6.6.3 Singly Symmetric Sections,

d. 6.6.4 Point-Symmetric Sections,

e. 6.6.5 Cylindrical Tubular Sections.

b. Members in compression and bending Resistance calculations are based on Clause 6.7.1, Singly and Doubly Symmetric Sections. Input for the coefficients of uniform bending must be provided by the user. The following table contains the input parameters for specifying values of design variables and selection of design options.

CANADIAN COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value Description

BEAM 1.0 When this parameter is set to 1.0 (default), the adequacy of the member is determined by checking a total of 13 equally spaced locations along the length of the member. If the BEAM value is 0.0, the 13 location check is not conducted, and instead, checking is done only at the locations specified by the SECTION command (See STAAD manual for details). If neither the BEAM parameter nor any SECTION command is specified, STAAD will terminate the run and ask the user to provide one of those 2 commands. This rule is not enforced for TRUSS members.

Page 203: International Design Codes

Section 3C 3-45

CANADIAN COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value Description

CMZ 1.0 Coefficient of equivalent uniform bending ωz. See CSA 136, 6.7.2. Used for Combined axial load and bending design. Values range from 0.4 to 1.0.

CMY 0.0 Coefficient of equivalent uniform bending ωy. See CSA 136, 6.7.2. Used for Combined axial load and bending design. Values range from 0.4 to 1.0.

CWY 0 Specifies whether the cold work of forming strengthening effect should be included in resistance computation. See CSA 136, 5.2.

Values: 0 – effect should not be included

1 – effect should be included

DMAX 1000.0 Maximum depth permissible for the section during member selection. This value must be provided in the current units.

DMIN 0.0 Minimum depth required for the section during member selection. This value must be provided in the current units.

FLX 1 Specifies whether torsional-flexural buckling restraint is provided or is not necessary for the member. See CSA 136, 6.6.2

Values:

0 – Section subject to torsional flexural buckling and restraint not provided

1 – restraint provided or unnecessary FU 450 MPa Ultimate tensile strength of steel in current units.

FYLD 350 MPa Yield strength of steel in current units.

Page 204: International Design Codes

Design Per Canadian Cold Fomed Steel Code

Section 3C 3-46

CANADIAN COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value Description

KT 1.0 Effective length factor for torsional buckling. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from torsional buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the capacity in axial compression.

KY 1.0 Effective length factor for overall column buckling about the local Y-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

KZ 1.0 Effective length factor for overall column buckling in the local Z-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

LT Member length

Unbraced length for twisting. It is input in the current units of length. Values can range from 0.01 (for a column completely prevented from torsional buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the capacity in axial compression.

LY Member length

Effective length for overall column buckling in the local Y-axis. It is input in the current units of length. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

Page 205: International Design Codes

Section 3C 3-47

CANADIAN COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value Description

LZ Member length

Effective length for overall column buckling in the local Z-axis. It is input in the current units of length. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

NSF 1.0 Net section factor for tension members, See CSA 136, 6.3.1.

STIFF Member length

Spacing in the longitudinal direction of shear stiffeners for stiffened flat webs. It is input in the current units of length. See section CSA 136, 6.4.5

TRACK 0 This parameter is used to control the level of detail in which the design output is reported in the output file. The allowable values are: 0 - Prints only the member number, section name, ratio,

and PASS/FAIL status. 1 - Prints the design summary in addition to that printed

by TRACK 1 2 - Prints member and material properties in addition to

that printed by TRACK 2. TSA 1 Specifies whether bearing and intermediate transverse

stiffeners satisfy the requirements of CSA 136, 6.5. If true, the program uses the more liberal set of interaction equations in 6.4.6.

Values:

0 – stiffeners do not comply with 6.5

1 – stiffeners comply with 6.5

Page 206: International Design Codes

Design Per Canadian Cold Fomed Steel Code

Section 3C 3-48

Page 207: International Design Codes

3-49

Wood Design Per CSA Standard CAN/CSA-086-01

Section 3D

3D.1 General Comments

The Canadian Wood Design facility in STAAD is based on CSA086-01. A timber section library consisting of Sawn and Glulam timber is available for member property specification. The design philosophy of this specification is based on the concept of limit state design. Structures are designed and proportioned taking into consideration the limit states at which they would become unfit for their intended use. Two major categories of limit-state are recognized - ultimate and serviceability. The primary considerations in ultimate limit state design are strength and stability, while that in serviceability is deflection. Appropriate load and resistance factors are used so that a uniform reliability is achieved for the entire structure under various loading conditions and at the same time the chances of limits being surpassed are acceptably remote. In the STAAD implementation, the code checking portion of the program checks whether code requirements for each selected section are met and identifies the governing criteria. The following sections describe the salient features of the STAAD implementation of CSA086-01. A detailed description of the design process along with its underlying concepts and assumptions is available in the specification document. Analysis MethodologyMember Property SpecificationsBuilt-in Section LibraryMember Resistances

Page 208: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-50 Design ParametersCode CheckingMember SelectionTabulated Results of Timber DesignVerification Examples

3D.2 Analysis Methodology

Analysis is done for the primary and combination loading conditions provided by the user. The user is allowed complete flexibility in providing loading specifications and using appropriate load factors to create necessary loading situations.

3D.3 Member Property Specifications

For specification of member properties, for Sawn timber the timber section library available in STAAD may be used. The next section describes the syntax of commands used to assign properties from the built-in timber table. For Glulam timber, member properties can be specified using the YD(depth) and ZD(width) specifications and selecting Combination and Species specifications from the built-in table. The assigment is done with the help of the PRISMATIC option which is explained in STAAD’s Technical Reference Manual.

3D.4 Built-in Section Library

The following information is provided for use when the built-in timber tables are to be referenced for member property specification. These properties are stored in a database file. If called for, the properties are also used for member design.

Page 209: International Design Codes

Section 3D 3-51

Following are the description of the different types of species combination available: Douglas Fir-Larch The following example illustrates the specification of Douglas Fir-Larch species combination.

100 TO 150 TABLE ST DFL_SelStr_2X2_BM

Hem-Fir Designation of Hem-Fir species combination in STAAD is as follows.

100 TO 150 TABLE ST Hem-Fir_SelStr_2X10_BM

Northern Species Designation of Northern species combination in STAAD is as follows.

100 TO 150 TABLE ST Northern_SelStr_3X12_BM

Spruce-Pine-Fir Designation of Spruce-Pine-Fir species combination in STAAD is as follows.

100 TO 150 TABLE ST SPF_SelStr_3X8_BM

DFL_SelStr_2X2_BM

Species Combination

Grade Nominal size

Size classification

Page 210: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-52 Glu Laminated timber Designation of Glu-lam timber in STAAD involves defining the material, specifying the dimensions, and associating the material with the member through the CONSTANTS command. UNIT CM KN DEFINE MATERIAL START ISOTROPIC GLT_D.Fir-L-24f-EX E 51611.7 POISSON 0.15 DENSITY 2.5e-005 ALPHA 1.2e-011 END DEFINE MATERIAL MEMBER PROPERTY TIMBER CANADIAN 1 PRIS YD 12 ZD 6 CONSTANTS MATERIAL GLT_D.Fir-L-24f-EX MEMB 1

GLT_D.Fir-L-24f-EX

Timber type

Species

Grade

Page 211: International Design Codes

Section 3D 3-53

Sample input file to demonstrate usage of Canadian timber STAAD PLANE EXAMPLE FOR DIMENSIONAL LUMBER UNIT FEET POUND JOINT COORDINATES 1 0 0 0; 2 6 0 0; 3 12 0 0; 4 18 0 0; 5 24 0 0; 6 6 3 0; 7 12 6 0; 8 18 3 0; MEMBER INCIDENCES 1 1 2; 2 2 3; 3 3 4; 4 4 5; 5 1 6; 6 6 7; 7 7 8; 8 8 5; 9 2 6; 10 3 7; 11 4 8; 12 6 3; 13 3 8; UNIT FEET POUND DEFINE MATERIAL START ISOTROPIC SPF_SelStr_4X10_BM E 1224 POISSON 0.15 DENSITY 25 ALPHA 5.5e-006 END DEFINE MATERIAL MEMBER PROPERTY tim can 1 TO 4 9 TO 11 TABLE ST SPF_SelStr_4X10_BM 5 TO 8 12 13 TABLE ST SPF_SelStr_4X10_BM CONSTANTS MATERIAL SPF_SelStr_4X10_BM memb 1 TO 4 9 TO 11 MATERIAL SPF_SelStr_4X10_BM memb 5 TO 8 12 13 PRINT MEMBER PROPERTIES FINISH

Page 212: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-54

3D.5 Member Resistance

The member resistances are calculated in STAAD according to the procedures outlined in section 5 (for sawn lumber) and 6(for Glulam) of CSA086-01. These depend on several adjustment factors as follows 1. KD = Load duration factor (Clause 4.3.2.2-CSA086-01, Table

4.3.2.2) 2. KH = System factor (Clause 5.4.4 and 6.4.3 and Table

5.4.4 -CSA086-01) 3. K_T = Treatment factor (Clause 5.4.3 and 6.4.4 -CSA086-

01) 4. KSB = Service condition factor applicable to Bending at

extreme fibre (Table 5.4.2 and 6.4.2 -CSA086-01) 5. KSV = Service condition factor applicable to longitudinal

shear (Table 5.4.2 and 6.4.2 CSA086-01) 6. KSC = Service condition factor applicable to Compression

parallel to the grain (Table 5.4.2 and 6.4.2 CSA086-01) 7. K_SCP = Service condition factor applicable to Compression

perpendicular to the grain (Table 5.4.2 and 6.4.2 CSA086-01) 8. KSE = Service condition factor applicable to modulus of

elasticity (Table 5.4.2 and 6.4.2 CSA086-01) 9. KST = Service condition factor applicable to tension parallel

to the grain (Table 5.4.2 and 6.4.2 CSA086-01) 10. KZB = Size factor applicable to bending (Clause 5.4.5 and

Table 5.4.5 -CSA086-01) 11. KZV = size factor applicable to shear(Clause 5.4.5 and Table

5.4.5 -CSA086-01) 12. KZT = size factor applicable to tension parallel to grain

(Clause 5.4.5 and Table 5.4.5 -CSA086-01) 13. KZCP = size factor applicable to compression perpendicular to

grain (Clause 5.4.5 and Table 5.4.5 -CSA086-01) 14. K_ZC = size factor applicable to compression parallel to grain

(Clause 5.4.5 and Table 5.4.5 -CSA086-01) 15. CHIX = Curvature factor (Clause 6.5.6.5.2-CSA086-01)

Page 213: International Design Codes

Section 3D 3-55

16. CV = shear load coefficient (Table 6.5.7.4A- CSA086-01) 17. KN = Notch factor(Clause 5.5.5.4-CSA086-01)

The user has to give all these factors as input according to the classification of timber and stress grade. Explained here is the procedure adopted in STAAD for calculating the member resistances. Axial Tension i) For Sawn timber The criterion governing the capacity of tension members is based on one limit state. The limit state involves fracture at the section with the minimum effective net area. The net section area may be specified by the user through the use of the parameter NSF (see Table 3B.1). STAAD calculates the tension capacity of a member based on this limit state per Clause 5.5.9 of CSA086-01. ii) For Glulam timber The design of glulam tension members differs from sawn timber since CSA 086-01 assigns different specified strength for gross and net section. The specified strength at net section is slightly higher than the strength of the gross section. Therefore, Glulam tension members are designed based on two limit states. The first one is the limit state of yielding in the gross section. The second limit state involves fracture at the section with the minimum effective net area. The net-section area may be specified by the user through the use of the parameter NSF (see Table 3B.1). STAAD calculates the tension capacity of a member based on these two limits states per Clause.6.5.11 of CSA086-01. Axial Compression The compressive resistance of columns is determined based on Clause.5.5.6 and Clause.6.5.8.4 of CSA086-01. The equations presented in this section of the code assume that the compressive resistance is a function of the compressive strength of the gross section (Gross section Area times the Yield Strength) as well as

Page 214: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-56 the slenderness factor (Kc). The effective length for the calculation of compression resistance may be provided through the use of the parameters KX, KY, KZ, LX, LY and LZ (see Table 3B.1). Bending The bending resistance of Sawn members are determined based on Clause 5.5.4 of CSA086-01 and for glulam members are determined based on Clause 6.5.6.5 of CSA086-01. The allowable stress in bending is multiplied by Lateral stability factor, KL to take in account whether lateral support is provided at points of bearing to prevent lateral displacement and rotation Axial compression and bending The member strength for sections subjected to axial compression and uni-axial or biaxial bending is obtained through the use of interaction equations. Clause 5.5.10 and 6.5.12 of the code provides the equations for this purpose. If the summation of the left hand side of these equations exceeds 1.0 or the allowable value provided using the RATIO parameter (see Table 3B.1), the member is considered to have FAILed under the loading condition. Axial tension and bending The member strength for sections subjected to axial tension and uniaxial or biaxial bending is obtained through the use of interaction equations. Clause 5.5.10 and 6.5.12 of the code provides the equations for this purpose. If the summation of the left hand side of these equations exceeds 1.0 or the allowable value provided using the RATIO parameter (see Table 3B.1), the member is considered to have FAILed under the loading condition.

Page 215: International Design Codes

Section 3D 3-57

Shear The shear resistance of the cross section is determined using the equations of Clause 5.5.5 and 6.5.7.2 of the code. Once this is obtained, the ratio of the shear force acting on the cross section to the shear resistance of the section is calculated. If any of the ratios (for both local Y & Z axes) exceed 1.0 or the allowable value provided using the RATIO parameter (see Table 3B.1), the section is considered to have failed under shear.

3D.6 Design Parameters

The design parameters outlined in Table below may be used to control the design procedure. These parameters communicate design decisions from the engineer to the program and thus allows the engineer to control the design process to suit an application's specific needs. The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements, some or all of these parameter values may be changed to exactly model the physical structure.

Canadian Timber design parameters Parameter

Name Default Value

Description

Nsf 1.0 Net section factor for tension members KX 1.0 K value for flexural torsional buckling KY 1.0 K value in local Y-axis, usually minor axis KZ 1.0 K value in local Z-axis, usually major axis

LX Member length

Length for flexural torsional buckling

LY Member length

Length in local Y axis for slenderness value KL/r

LZ Member length

Length in local Z axis for slenderness value KL/r

Page 216: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-58

Canadian Timber design parameters Parameter

Name Default Value

Description

KD 1.0 Load Duration Factor [Clause.4.3.2, Table 4.3.2]

KH 1.0 System Factor [Clause 5.4.4/6.4.3, Table 5.4.4]

K_T 1.0 Treatment Factor [Clause 5.4.3/6.4.4]

KSB 1.0

Service Condition Factor for Bending at Extreme Fibre Applicable for bending at extreme fibre [Table 5.4.2 and 6.4.2]

KSV 1.0 Service Condition Factor for Shear, Applicable for longitudinal shear [Table 5.4.2 and 6.4.2]

KSC 1.0 Service Condition Factor for Compression, Applicable for compression parallel to grain [Table 5.4.2 and 6.4.2]

KSE 1.0

Service Condition Factor for Modulus of Elasticity, Applicable for modulus of elasticty [Table 5.4.2 and 6.4.2]

KST 1.0 Service Condition Factor for Tension, Applicable for tension parallel to grain [Table 5.4.2 and 6.4.2]

KZB 1.0 Size Factor for Bending, Applicable for bending [Clause.5.4.5 and Table 5.4.5]

KZV 1.0 Size Factor for Shear [Clause 5.4.5 and Table 5.4.5]

KZT 1.0 Size Factor for Tension, Applicable for tension parallel to grain [Clause 5.4.5 and Table 5.4.5]

KZCP 1.0 Size Factor for Compression, Applicable for compression perpendicular to grain [Clause .5.4.5 and Table 5.4.5]

Page 217: International Design Codes

Section 3D 3-59

Canadian Timber design parameters Parameter

Name Default Value

Description

K_ZC 1.0 Size Factor for Compression, Applicable for compression parallel to grain [Clause 5.4.5 and Table 5.4.5]

CV 1.0 Shear Load Coefficient [Table 6.5.7.4A] KN 1.0 Notch Factor [Clause 5.4.7.2.2]

K_SCP 1.0 Service Condition Factor for Compression, Applicable for compression perpendicular to grain [Clause 5.4.2 and Table 6.4.2]

CHIX 1.0 Curvature Factor for Compression [Clause 6.5.6.5.2]

RATIO 1.0 Permissible Ratio of Actual to Allowable Value

3D.7 Code Checking

The purpose of code checking is to check whether the provided section properties of the members are adequate. The adequacy is checked as per the CSA086-01 requirements. Code checking is done using forces and moments at specified sections of the members. The code checking output labels the members as PASSed or FAILed. In addition, the critical condition, governing load case, location (distance from the start joint) and magnitudes of the governing forces and moments are also printed.

Page 218: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-60 PARAMETER CODE TIMBER CAN KD 0.99 ALL KH 0.99 ALL K_T 0.99 ALL KSB 0.99 ALL KSV 0.99 ALL KSC 0.99 ALL KSE 0.99 ALL KST 0.99 ALL KZB 0.99 ALL KZV 0.99 ALL KZT 0.99 ALL KZCP 0.99 ALL K_ZC 0.99 ALL CV 0.99 ALL KN 0.99 ALL K_SCP 0.99 ALL CHIX 0.99 ALL RATIO 0.99 ALL CHECK CODE ALL FINISH

3D.8 Member Selection

Member selection based CSA086-2001 is not available.

3D.9 Tabulated Results of Timber Design

Results of code checking and member selection are presented in a tabular format. The term CRITICAL COND refers to the section of the CSA086-01 specification, which governed the design. Pu = Actual Load in Compression Tu = Actual Load in Tension Muy = Ultimate moment in y direction Muz = Ultimate moment in z direction V = Ultimate shear force

Page 219: International Design Codes

Section 3D 3-61

SLENDERNESS_Y = Actual Slenderness ratio in y direction SLENDERNESS_Z = Actual Slenderness ratio in z direction PY = Factored Compressive capacity in y direction PZ = Factored Compressive capacity in z direction T = Factored tensile capacity MY = Factored moment of resistance in y direction MZ = Factored moment of resistance in z direction V = Factored shear resistance SLENDERNESS = Allowable slenderness ratio

3D.10 Verification Problems

In the next few pages are included 6 verification examples for reference purposes.

Page 220: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-62

Verification Problem: 1 Objective: - To determine the Canadian Glulam section column in

axial compression. Column is effectively pinned at both ends and braced at mid-height in all direction..

Design Code: - Canadian wood design code (CSA:086-01) Reference: - Example 4, page 116, Canadian Wood Design Manual, 2001 Given: - Length = 9000mm Comparison: -

Solution Design Strength (kN) Theory 295 STAAD 293.739 Difference -0.427 %

Input: - STAAD PLANE EXAMPLE FOR GLULAM DESIGN INPUT FILE: GLULAMCOLUMN.STD START JOB INFORMATION ENGINEER DATE 10-JUN-05 END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 0 9 0; MEMBER INCIDENCES 1 1 2; UNIT INCHES KIP DEFINE MATERIAL START ISOTROPIC GLT_SPRUCE-PINE-12C-E E 9.7 POISSON 0.15 DENSITY 1.44676e-005 ALPHA 5.5e-006 END DEFINE MATERIAL UNIT FEET POUND

Page 221: International Design Codes

Section 3D 3-63

MEMBER PROPERTY TIMBER CANADIAN 1 PRIS YD 0.748031 ZD 0.574147 UNIT INCHES KIP CONSTANTS MATERIAL GLT_SPRUCE-PINE-12C-E MEMB 1 SUPPORTS 1 PINNED UNIT METER KN LOAD 1 LOADTYPE None TITLE LOAD CASE 1 JOINT LOAD 2 FY -214 PERFORM ANALYSIS PARAMETER CODE TIMBER CANADIAN KY 0.5 ALL KZ 0.5 ALL CHECK CODE ALL FINISH Relevant portion of Output:- STAAD.Pro CODE CHECKING - (S086) *********************** ALL UNITS ARE - KN METE (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 1 175.00X228.00 CANADIAN GLULAM GRADE:GLT_SPRUCE-PINE-12C-E PASS CL.5.5.10/6.5 0.728 1 214.00 C 0.00 0.00 0.0000 |--------------------------------------------------------------------------| | LEZ = 4500.000 LEY = 4500.000 LUZ = 9000.000 LUY = 9000.000mm | | | | KD = 1.000 KH = 1.000 KT = 1.000 KSB = 1.000 KSV = 1.000 | | KSC = 1.000 K_SCP = 1.000 KSE = 1.000 KST = 1.000 KZB = 1.000 | | KZV = 1.000 KZT = 1.000 KZCP = 1.000 K_ZC = 1.000 CHIX = 1.000 | | CV = 1.000 KN = 1.000 | | | | ACTUAL LOADS : (KN-m) | | Pu = 214.000 | | Tu = 0.000 | | Muy = 0.000 | | Muz = 0.000 | | V = 0.000 | | SLENDERNESS_Y = 19.737 | | SLENDERNESS_Z = 25.714 | | ALLOWABLE CAPACITIES OF THE SECTION: (KN-m) | | PY = 413.943 | | PZ = 293.793 | | T = 0.000 | | MY = 0.000 | | MZ = 0.000 | | V = 0.000 | | SLENDERNESS = 50.000 | |--------------------------------------------------------------------------| 37. FINISH

Page 222: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-64

Verification Problem: 2 Objective: - To determine the bending capacity of a Canadian

Glulam section single span floor beam. The compression edge assumed fully supported.

Design Code: - Canadian wood design code (CSA:086-01) Reference: - Example 2, page 59, Canadian Wood Design Manual, 2001 Given: - Length =7500mm, Beam Spacing = 5000mm, Standard load

condition, Dry service condition, Untreated Comparison: -

Input: -

STAAD PLANE EXAMPLE FOR GLULAM DESIGN INPUT FILE: glulamBEAM.STD START JOB INFORMATION ENGINEER DATE 10-JUN-05 END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 7.5 0 0 MEMBER INCIDENCES 1 1 2 UNIT INCHES KIP DEFINE MATERIAL START ISOTROPIC GLT_SPRUCE-PINE-12C-E

Solution Design Strength in bending (kN-m)

Design Strength in shear (kN)

Theory 208 101 STAAD 208.323 100.776 Difference 0.155 % -0.221 %

Page 223: International Design Codes

Section 3D 3-65

E 9.7 POISSON 0.15 DENSITY 1.44676E-005 ALPHA 5.5E-006 ISOTROPIC GLT_D.FIR-L-20F-E E 12.4 POISSON 0.15 DENSITY 1.44676E-005 ALPHA 5.5E-006 ISOTROPIC CONCRETE E 3150 POISSON 0.17 DENSITY 8.68E-005 ALPHA 5.5E-006 DAMP 0.05 END DEFINE MATERIAL UNIT FEET POUND MEMBER PROPERTY TIMBER CANADIAN 1 PRIS YD 2.11942 ZD 0.426508 UNIT INCHES KIP CONSTANTS MATERIAL GLT_D.FIR-L-20F-E MEMB 1 SUPPORTS 1 2 PINNED UNIT METER KN LOAD 1 LOADTYPE NONE TITLE LOAD CASE 1 MEMBER LOAD 1 UNI GY -27.1 PERFORM ANALYSIS PARAMETER CODE TIMBER CANADIAN CHECK CODE ALL FINISH

Page 224: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-66 Relevant portion of Output:- STAAD.Pro CODE CHECKING - (S086) *********************** ALL UNITS ARE - KN METE (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 1 130.00X646.00 CANADIAN GLULAM GRADE:GLT_D.FIR-L-20F-E FAIL CL.5.5.5/6.5. 1.008 1 0.00 T 0.00 0.00 0.0000 |--------------------------------------------------------------------------| | LEZ = 7500.000 LEY = 7500.000 LUZ = 7500.000 LUY = 7500.000mm | | | | KD = 1.000 KH = 1.000 KT = 1.000 KSB = 1.000 KSV = 1.000 | | KSC = 1.000 K_SCP = 1.000 KSE = 1.000 KST = 1.000 KZB = 1.000 | | KZV = 1.000 KZT = 1.000 KZCP = 1.000 K_ZC = 1.000 CHIX = 1.000 | | CV = 1.000 KN = 1.000 | | | | ACTUAL LOADS : (KN-m) | | Pu = 0.000 | | Tu = 0.000 | | Muy = 0.000 | | Muz = 0.000 | | V = 101.625 | | SLENDERNESS_Y = 16.932 | | SLENDERNESS_Z = 1.529 | | ALLOWABLE CAPACITIES OF THE SECTION: (KN-m) | | PY = 0.000 | | PZ = 0.000 | | T = 0.000 | | MY = 41.923 | | MZ = 208.323 | | V = 100.776 | | SLENDERNESS = 50.000 | |--------------------------------------------------------------------------| 46. FINISH

Page 225: International Design Codes

Section 3D 3-67

Verification Problem: 3

Objective: - To determine the capacity of a Canadian Glulam section in axial tension.

Design Code: - Canadian wood design code (CSA:086-01) Reference: - Example 3, page 158, Canadian Wood Design

Manual, 2001 Given: - Dry service condition, Untreated Comparison: -

Solution Design Strength in Tension (kN)

Theory 257 STAAD 256.636 Difference -0.141 %

Input: - STAAD PLANE EXAMPLE FOR GLULAM DESIGN INPUT FILE: glulamTENSION.STD START JOB INFORMATION ENGINEER DATE 10-JUN-05 END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 0 9 0 MEMBER INCIDENCES 1 1 2 UNIT INCHES KIP DEFINE MATERIAL START ISOTROPIC GLT_SPRUCE-PINE-14T-E E 10.7 POISSON 0.15 DENSITY 1.44676E-005 ALPHA 5.5E-006 ISOTROPIC CONCRETE

Page 226: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-68 E 3150 POISSON 0.17 DENSITY 8.68E-005 ALPHA 5.5E-006 DAMP 0.05 END DEFINE MATERIAL UNIT FEET POUND MEMBER PROPERTY TIMBER CANADIAN 1 PRIS YD 0.872702 ZD 0.262467 UNIT INCHES KIP CONSTANTS MATERIAL GLT_SPRUCE-PINE-14T-E MEMB 1 SUPPORTS 1 PINNED UNIT METER KN LOAD 1 LOADTYPE NONE TITLE LOAD CASE 1 JOINT LOAD 2 FY 250 PERFORM ANALYSIS PRINT STATICS CHECK PARAMETER CODE TIMBER CANADIAN KY 0.5 ALL KZ 0.5 ALL CHECK CODE ALL FINISH

Page 227: International Design Codes

Section 3D 3-69

Relevant portion of Output:- STAAD.Pro CODE CHECKING - (S086) *********************** ALL UNITS ARE - KN METE (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 1 80.00X266.00 CANADIAN GLULAM GRADE:GLT_SPRUCE-PINE-14T-E PASS CL.5.5.10/6.5 0.974 1 250.00 T 0.00 0.00 0.0000 |--------------------------------------------------------------------------| | LEZ = 4500.000 LEY = 4500.000 LUZ = 9000.000 LUY = 9000.000mm | | | | KD = 1.000 KH = 1.000 KT = 1.000 KSB = 1.000 KSV = 1.000 | | KSC = 1.000 K_SCP = 1.000 KSE = 1.000 KST = 1.000 KZB = 1.000 | | KZV = 1.000 KZT = 1.000 KZCP = 1.000 K_ZC = 1.000 CHIX = 1.000 | | CV = 1.000 KN = 1.000 | | | | ACTUAL LOADS : (KN-m) | | Pu = 0.000 | | Tu = -250.000 | | Muy = 0.000 | | Muz = 0.000 | | V = 0.000 | | ALLOWABLE CAPACITIES OF THE SECTION: (KN-m) | | PY = 0.000 | | PZ = 0.000 | | T = 256.636 | | MY = 0.000 | | MZ = 0.000 | | V = 0.000 | |--------------------------------------------------------------------------|

Page 228: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-70

Verification Problem: 4

Objective: - To determine the Canadian Sawn section column in axial compression. Column is effectively pinned at both ends.

Design Code: - Canadian wood design code (CSA:086-01) Reference: - Example 2, page 113, Canadian Wood Design Manual, 2001 Given: - Unbraced Length = 5000mm Comparison: -

Solution Design Strength (kN) Theory 130 STAAD 129.223 Difference -0.597 %

Input: - STAAD PLANE EXAMPLE FOR DIMENSIONAL LUMBER INPUT FILE: sawn_ lumber_ COLUMN.STD START JOB INFORMATION ENGINEER DATE 08-JUN-05 END JOB INFORMATION UNIT FEET POUND JOINT COORDINATES 1 0 0 0; 2 0 16.4042 0 MEMBER INCIDENCES 1 1 2 DEFINE MATERIAL START ISOTROPIC DFL_NO2_8X8_POST E 1.368E+006 POISSON 0.15 DENSITY 25 ALPHA 5.5E-006 END DEFINE MATERIAL UNIT METER KN CONSTANTS MATERIAL DFL_NO2_8X8_POST MEMB 1

Page 229: International Design Codes

Section 3D 3-71

UNIT FEET POUND MEMBER PROPERTY TIMBER CANADIAN 1 TABLE ST DFL_NO2_8X8_POST SUPPORTS 1 PINNED UNIT METER KN LOAD 1 DEAD+LIVE LOAD JOINT LOAD 2 FY -114 PERFORM ANALYSIS PRINT STATICS CHECK PARAMETER CODE TIMBER CANADIAN KSC 0.91 ALL K_ZC 1.05 ALL CHECK CODE FINISH Relevant portion of Output:- STAAD.Pro CODE CHECKING - (S086) *********************** ALL UNITS ARE - KN METE (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 1 ST DFL_NO2_8X8_POST PASS CL.5.5.10/6.5.12 0.882 1 114.00 C 0.00 0.00 0.0000 |--------------------------------------------------------------------------| | LEZ = 5000.000 LEY = 5000.000 LUZ = 5000.000 LUY = 5000.000mm | | | | KD = 1.000 KH = 1.000 KT = 1.000 KSB = 1.000 KSV = 1.000 | | KSC = 0.910 K_SCP = 1.000 KSE = 1.000 KST = 1.000 KZB = 1.000 | | KZV = 1.000 KZT = 1.000 KZCP = 1.000 K_ZC = 1.050 CHIX = 1.000 | | CV = 1.000 KN = 1.000 | | | | ACTUAL LOADS : (KN-m) | | Pu = 114.000 | | Tu = 0.000 | | Muy = 0.000 | | Muz = 0.000 | | V = 0.000 | | SLENDERNESS_Y = 26.178 | | SLENDERNESS_Z = 26.178 | | ALLOWABLE CAPACITIES OF THE SECTION: (KN-m) | | PY = 129.223 | | PZ = 129.223 | | T = 0.000 | | MY = 0.000 | | MZ = 0.000 | | V = 0.000 | | SLENDERNESS = 50.000 | |--------------------------------------------------------------------------|

Page 230: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-72

Verification Problem: 5

Objective: - To determine the bending capacity of a Canadian sawn section single span floor beam.

Design Code: - Canadian wood design code (CSA:086-01) Reference: - Example 1, page 58, Canadian Wood Design Manual,

2001 Given: - Length =6000mm, Beam Spacing = 3000mm, Standard

load condition, Dry service condition, Untreated Comparison: -

Solution Design Strength in bending (kN-m)

Design Strength in shear (kN)

Theory 79.8 46.1 STAAD 79.732 46.170 Difference -0.085 % No

Input: - STAAD PLANE EXAMPLE FOR DIMENSIONAL LUMBER: SAWN_LUMBER_BEAM.STD START JOB INFORMATION ENGINEER DATE 08-JUN-05 END JOB INFORMATION UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 6 0 0; 3 3 0 0; MEMBER INCIDENCES 1 1 3; 2 3 2; UNIT FEET POUND DEFINE MATERIAL START ISOTROPIC DFL_NO1_10X16_BM E 1.728e+006 POISSON 0.15 DENSITY 25 ALPHA 5.5e-006 END DEFINE MATERIAL UNIT METER KN CONSTANTS

Page 231: International Design Codes

Section 3D 3-73

MATERIAL DFL_NO1_10X16_BM MEMB 1 2 UNIT FEET POUND MEMBER PROPERTY TIMBER CANADIAN 1 2 TABLE ST DFL_NO1_10X16_BM SUPPORTS 1 2 FIXED UNIT METER KN LOAD 1 DEAD+LIVE LOAD MEMBER LOAD 1 2 UNI GY -16.4 PERFORM ANALYSIS PARAMETER CODE TIMBER CANADIAN KD 1.0 ALL K_T 1.0 ALL KSB 1.0 ALL KZB 0.90 ALL KZV 0.90 ALL K_ZC 1.05 ALL CHECK CODE ALL FINISH Relevant portion of Output:- ALL UNITS ARE - KN METE (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 2 ST DFL_NO1_10X16_BM FAIL CL.5.5.5/6.5.6 1.066 1 0.00 T 0.00 49.20 3.0000 |--------------------------------------------------------------------------| | LEZ = 3000.000 LEY = 3000.000 LUZ = 3000.000 LUY = 3000.000mm | | | | KD = 1.000 KH = 1.000 KT = 1.000 KSB = 1.000 KSV = 1.000 | | KSC = 1.000 K_SCP = 1.000 KSE = 1.000 KST = 1.000 KZB = 0.900 | | KZV = 0.900 KZT = 1.000 KZCP = 1.000 K_ZC = 1.050 CHIX = 1.000 | | CV = 1.000 KN = 1.000 | | | | ACTUAL LOADS : (KN-m) | | Pu = 0.000 | | Tu = 0.000 | | Muy = 0.000 | | Muz = 49.200 | | V = -49.200 | | SLENDERNESS_Y = 4.511 | | SLENDERNESS_Z = 2.158 | | ALLOWABLE CAPACITIES OF THE SECTION: (KN-m) | | PY = 0.000 | | PZ = 0.000 | | T = 0.000 | | MY = 79.800 | | MZ = 79.732 | | V = 46.170 | | SLENDERNESS = 50.000 | |--------------------------------------------------------------------------|

Page 232: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-74

Verification Problem: 6

Objective: - To determine the capacity of a Canadian Sawn section in axial tension.

Design Code: - Canadian wood design code (CSA:086-01) Reference: - Example 2, page 158, Canadian Wood Design Manual, 2001 Given: - Dry service condition, Untreated Comparison: -

Solution Design Strength in Tension (kN)

Theory 185 STAAD 184.338 Difference -0.357%

Input: - STAAD PLANE EXAMPLE FOR DIMENSIONAL LUMBER SAWN_LUMBER_TENSION.STD START JOB INFORMATION ENGINEER DATE 08-JUN-05 END JOB INFORMATION UNIT FEET POUND JOINT COORDINATES 1 0 0 0; 2 0 16.4042 0; MEMBER INCIDENCES 1 1 2; DEFINE MATERIAL START ISOTROPIC DFL_NO1_6X8_BM E 1.728e+006 POISSON 0.15 DENSITY 25 ALPHA 5.5e-006 END DEFINE MATERIAL UNIT METER KN CONSTANTS MATERIAL DFL_NO1_6X8_BM MEMB 1

Page 233: International Design Codes

Section 3D 3-75

UNIT FEET POUND MEMBER PROPERTY TIMBER CANADIAN 1 TABLE ST DFL_NO1_6X8_BM SUPPORTS 1 PINNED UNIT METER KN LOAD 1 DEAD+LIVE LOAD JOINT LOAD 2 FY 144 PERFORM ANALYSIS PRINT STATICS CHECK PARAMETER CODE TIMBER CANADIAN KH 1.1 ALL KSC 0.91 ALL K_ZC 1.05 ALL CHECK CODE ALL FINISH Relevant portion of Output:- STAAD.Pro CODE CHECKING - (S086) *********************** ALL UNITS ARE - KN METE (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 1 ST DFL_NO1_6X8_BM PASS CL.5.5.10/6.5.12 0.781 1 144.00 T 0.00 0.00 0.0000 |--------------------------------------------------------------------------| | LEZ = 5000.000 LEY = 5000.000 LUZ = 5000.000 LUY = 5000.000mm | | | | KD = 1.000 KH = 1.100 KT = 1.000 KSB = 1.000 KSV = 1.000 | | KSC = 0.910 K_SCP = 1.000 KSE = 1.000 KST = 1.000 KZB = 1.000 | | KZV = 1.000 KZT = 1.000 KZCP = 1.000 K_ZC = 1.050 CHIX = 1.000 | | CV = 1.000 KN = 1.000 | | | | ACTUAL LOADS : (KN-m) | | Pu = 0.000 | | Tu = -144.000 | | Muy = 0.000 | | Muz = 0.000 | | V = 0.000 | | ALLOWABLE CAPACITIES OF THE SECTION: (KN-m) | | PY = 0.000 | | PZ = 0.000 | | T = 184.338 | | MY = 0.000 | | MZ = 0.000 | | V = 0.000 | |--------------------------------------------------------------------------|

Page 234: International Design Codes

Design Per Canadian Timber Code

Section 3D 3-76

Page 235: International Design Codes

Section 4 Chinese Codes

Page 236: International Design Codes

Kjahds;akh

Page 237: International Design Codes

4-1

Concrete Design Per GB50010-2002

4A.1 Design Operations

STAAD has the capabilities for performing concrete design per GB50010-2002. It can calculate the reinforcement needed for sections assigned through the PRISMATIC attribute. The concrete design calculations are based on the limit state method of GB50010-2002.

4A.2 Section Types for Concrete Design

The following types of cross sections for concrete members can be designed. For Beams Prismatic (Rectangular, Square, Tee and

Trapezoidal) For Columns Prismatic (Rectangular, Square and Circular)

4A.3 Member Dimensions

Concrete members which will be designed by the program must have certain section properties input under the MEMBER PROPERTY command. The following example shows the required input:

Section 4A

Page 238: International Design Codes

Concrete Design Per GB50010-2002 Section 4A 4-2

UNIT MM MEMBER PROPERTY 1 3 TO 7 9 PRISM YD 450. ZD 250. 11 13 PR YD 350. 14 TO 16 PRIS YD 400. ZD 750. YB 300. ZB 200.

will be done accordingly. In the above input, the first set of members are rectangular (450 mm depth and 250mm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with 350 mm diameter. The third set numbers in the above example represents a T-shape with 750 mm flange width, 200 width, 400 mm overall depth and 100 mm flange depth (See section 6.20.2). The program will determine whether the section is rectangular, flanged or circular and the beam or column design

4A.4 Design Parameters

The program contains a number of parameters which are needed to perform design as per GB50010-2002. Default parameter values have been selected such that they are frequently used numbers for conventional design requirements. These values may be changed to suit the particular design being performed. Table 9A.1 of this manual contains a complete list of the available parameters and their default values. It is necessary to declare length and force units as Millimeter and Newton before performing the concrete design. Please note as per GB50010-2002, STAAD supports Characteristic Values of Concrete Strength and Design Value of Strength of Steel Bar only as per Table 4.1.4 and Table 4.2.3-1 respectively.

4A.5 Beam Design

Beams are designed for flexure, shear and torsion. If required the effect the axial force may be taken into consideration. For all

Page 239: International Design Codes

Section 4A 4-3

these forces, all active beam loadings are prescanned to identify the critical load cases at different sections of the beams. The total number of sections considered is 13( e.g. 0.,.1,.2,.25,.3,.4,.5,.6,.7,.75,.8,.9 and 1). All of these sections are scanned to determine the design force envelopes. Design for Flexure

Maximum sagging (creating tensile stress at the bottom face of the beam) and hogging (creating tensile stress at the top face) moments are calculated for all active load cases at each of the above mentioned sections. Each of these sections are designed to resist both of these critical sagging and hogging moments. Where ever the rectangular section is inadequate as singly reinforced section, doubly reinforced section is tried. However, presently the flanged section are designed only as singly reinforced section under sagging moment. It may also be noted all flanged sections are automatically designed as rectangular section under hogging moment as the flange of the beam is ineffective under hogging moment. Flexural design of beams are performed in two passes. In the first pass, effective depths of the sections are determined with the assumption of single layer of assumed reinforcement and reinforcement requirements are calculated. After the preliminary design, reinforcing bars are chosen from the internal database in single or multiple layers. The entire flexure design is performed again in a second pass taking into account of the changed effective depths of sections calculated on the basis of reinforcement provide after the preliminary design. Final provision of flexural reinforcements are made then. Efforts have been made to meet the guideline for the reinforcement detailing as per GB50010-2002 Although exact curtailment lengths are not mentioned explicitly in the design output (finally which will be more or less guided by the detailer taking into account of other practical consideration), user has the choice of printing reinforcements provided by STAAD at 11 equally spaced sections from which the final detail drawing can be prepared.

Page 240: International Design Codes

Concrete Design Per GB50010-2002 Section 4A 4-4

Design for Shear

Shear reinforcement is calculated to resist both shear forces and torsional moments. Shear design are performed at 11 equally spaced sections (0.to 1.) for the maximum shear forces amongst the active load cases and the associated torsional moments. Shear capacity calculation at different sections without the shear reinforcement is based on the actual tensile reinforcement provided by STAAD program. Two-legged stirrups are provided to take care of the balance shear forces acting on these sections. Beam Design Output

The default design output of the beam contains flexural and shear reinforcement provided at 5 equally spaced (0,.25,.5,.75 and 1.) sections along the length of the beam. User has option to get a more detail output. All beam design outputs are given in IS units. An example of rectangular beam design output with the default output option (TRACK 0.0) is presented below:

Page 241: International Design Codes

Section 4A 4-5

============================================================================ B E A M N O. 12 D E S I G N R E S U L T S C20 HRB400 (Main) HRB400 (Sec.) LENGTH: 4000.0 mm SIZE: 250.0 mm X 350.0 mm COVER: 30.0 mm DESIGN LOAD SUMMARY (KN MET) ---------------------------------------------------------------------------- SECTION |FLEXTURE (Maxm. Sagging/Hogging moments)| SHEAR (in mm) | P MZ MX Load Case | VY MX Load Case ---------------------------------------------------------------------------- 0.0 | 0.00 0.00 0.00 4 | 29.64 1.23 4 | 0.00 -25.68 1.23 4 | 400.0 | 0.00 0.00 0.00 4 | 27.97 1.23 4 | 0.00 -16.05 1.23 4 | 800.0 | 0.00 0.00 0.00 4 | 25.12 1.23 4 | 0.00 -7.17 1.23 4 | 1200.0 | 0.00 0.97 0.49 5 | 21.11 1.23 4 | 0.00 -0.14 1.32 6 | 1600.0 | 0.00 6.77 1.23 4 | 15.93 1.23 4 | 0.00 0.00 0.00 4 | 2000.0 | 0.00 11.06 1.23 4 | 9.59 1.23 4 | 0.00 0.00 0.00 4 | 2400.0 | 0.00 13.04 1.23 4 | 2.08 1.23 4 | 0.00 0.00 0.00 4 | 2800.0 | 0.00 12.45 1.23 4 | -5.43 1.23 4 | 0.00 0.00 0.00 4 | 3200.0 | 0.00 9.55 1.23 4 | -11.77 1.23 4 | 0.00 0.00 0.00 4 | 3600.0 | 0.00 4.73 1.23 4 | -16.95 1.23 4 | 0.00 0.00 0.00 4 | 4000.0 | 0.00 0.00 0.00 4 | -25.48 1.23 4 | 0.00 -17.36 1.23 4 | ---------------------------------------------------------------------------- SUMMARY OF REINF. AREA (Sq.mm) ---------------------------------------------------------------------------- SECTION 0.0 mm 1000.0 mm 2000.0 mm 3000.0 mm 4000.0 mm ---------------------------------------------------------------------------- TOP 259.04 161.29 0.00 0.00 176.31 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) BOTTOM 0.00 160.78 160.78 160.78 0.00 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) ---------------------------------------------------------------------------- SUMMARY OF PROVIDED REINF. AREA ---------------------------------------------------------------------------- SECTION 0.0 mm 1000.0 mm 2000.0 mm 3000.0 mm 4000.0 mm ---------------------------------------------------------------------------- TOP 4-10Ø 3-10Ø 2-10Ø 2-10Ø 3-10Ø REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) BOTTOM 2-12Ø 2-12Ø 2-12Ø 2-12Ø 2-12Ø REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) SHEAR 2 legged 8Ø 2 legged 8Ø 2 legged 8Ø 2 legged 8Ø 2 legged 8Ø REINF. @ 100 mm c/c @ 100 mm c/c @ 100 mm c/c @ 100 mm c/c @ 100 mm c/c ----------------------------------------------------------------------------

============================================================================

Page 242: International Design Codes

Concrete Design Per GB50010-2002 Section 4A 4-6

4A.6 Column Design

Columns are designed for axial forces and biaxial moments at the ends. All active load cases are tested to calculate reinforcement. The loading which yield maximum reinforcement is called the critical load. Column design is done for square, rectangular and circular sections. By default, square and rectangular columns and designed with reinforcement distributed on each side equally for the sections under biaxial moments and with reinforcement distributed equally in two faces for sections under uniaxial moment. User may change the default arrangement of the reinforcement with the help of the parameter RFACE (see Table 4A.1). Depending upon the member lengths, section dimensions and effective length coefficients specified by the user STAAD automatically determine the criterion (short or long) of the column design. All major criteria for selecting longitudinal and transverse reinforcement as stipulated by GB50010-2002 have been taken care of in the column design of STAAD. Column Design Output

Default column design output (TRACK 0.0) contains the reinforcement provided by STAAD and the capacity of the section. With the option TRACK 1.0, the output contains intermediate results such as the design forces, effective length coefficients, additional moments etc. A special output TRACK 9.0 is introduced to obtain the details of section capacity calculations. All design output is given in SI units. An example of a long column design output (with option TRACK 1.0) is given below.

Page 243: International Design Codes

Section 4A 4-7

============================================================================ C O L U M N No. 1 D E S I G N R E S U L T S C20 HRB400 (Main) HRB400 (Sec.) LENGTH: 3000.0 mm CROSS SECTION: 250.0 mm dia. COVER: 40.0 mm ** GUIDING LOAD CASE: 5 BRACED LONG COLUMN DESIGN FORCES (KNS-MET) ----------------------- DESIGN AXIAL FORCE (Pu) : 62.0 About Z About Y INITIAL MOMENTS : 2.21 32.29 MOMENTS DUE TO MINIMUM ECC. : 1.24 1.24 SLENDERNESS RATIOS : 12.00 12.00 MOMENTS DUE TO SLENDERNESS EFFECT : 1.12 1.12 MOMENT REDUCTION FACTORS : 1.00 1.00 ADDITION MOMENTS (Maz and May) : 1.12 1.12 TOTAL DESIGN MOMENTS : 3.32 33.40 REQD. STEEL AREA : 1822.71 Sq.mm. MAIN REINFORCEMENT : Provide 17 - 12 dia. (3.92%, 1922.65 Sq.mm.) (Equally distributed) TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c SECTION CAPACITY (KNS-MET) -------------------------- Puz : 992.70 Muz1 : 36.87 Muy1 : 36.87 INTERACTION RATIO: 1.00

============================================================================

Page 244: International Design Codes

Concrete Design Per GB50010-2002 Section 4A 4-8

Table 4A.1 Chinese Concrete Design GB50010-2002 Parameters

Parameter Default Description Name Value FYMAIN 210 N/mm2 Yield Stress for main reinforcing

steel.

FYSEC 210 N/mm2 Yield Stress for secondary reinforcing steel.

FC 15 N/mm2 Concrete Yield Stress.

CLEAR 25 mm 40 mm

For beam members. For column members

MINMAIN 10 mm Minimum main reinforcement bar size.

MAXMAIN 60 mm Maximum main reinforcement bar size.

MINSEC 8 mm Minimum secondary reinforcement bar size.

MAXSEC 12 mm Maximum secondary reinforcement bar size.

BRACING 0.0 BEAM DESIGN

A value of 1.0 means the effect of axial force will be taken into account for beam design.

COLUMN DESIGN

A value of 1.0 means the column is unbraced about major axis.

A value of 2.0 means the column is unbraced about minor axis.

A value of 3.0 means the column is unbraced about both axis.

RATIO 4.0 Maximum percentage of longitudinal reinforcement in columns.

Page 245: International Design Codes

Section 4A 4-9

Table 4A.1 Chinese Concrete Design GB50010-2002 Parameters

Parameter Default Description Name Value RFACE 4.0 A value of 4.0 means longitudinal

reinforcement in column is arranged equally along 4 faces.

A value of 2.0 invokes 2 faced distribution about major axis.

A value of 3.0 invokes 2 faced distribution about minor axis.

WIDTH ZD Width to be used for design. This value defaults to ZD as provided under MEMBER PROPERTIES.

DEPTH YD Total depth to be used for design. This value defaults to YD as provided under MEMBER PROPERTIES.

TRACK 0.0 BEAM DESIGN: For TRACK = 0.0, output consists of reinforcement details at START, MIDDLE and END. For TRACK = 1.0, critical moments are printed in addition to TRACK 0.0 output. For TRACK = 2.0, required steel for intermediate sections defined by NSECTION are printed in addition to TRACK 1.0 output.

COLUMN DESIGN: With TRACK = 0.0, reinforcement details are printed. With TRACK = 1.0, column interaction analysis results are printed in addition to TRACK 0.0 output. With TRACK = 2.0, a schematic interaction diagram and intermediate interaction values are printed in addition to TRACK 1.0 output.

REINF 0.0 Tied column. A value of 1.0 will mean spiral reinforcement.

Page 246: International Design Codes

Concrete Design Per GB50010-2002 Section 4A 4-10

Table 4A.1 Chinese Concrete Design GB50010-2002 Parameters

Parameter Default Description Name Value ELZ 1.0 Ratio of effective length to actual

length of column about major axis.

ELY 1.0 Ratio of effective length to actual length of column about minor axis.

Page 247: International Design Codes

4-11

Steel Design Per GBJ 17- 88

4B.1 General

This section presents some general statements regarding the implementation in STAAD of the National Standard of the People’s Republic of China specifications for Design of Steel Structures (GBJ 17-88). The design philosophy and procedural logistics are based on the principles of limit state design method. Facilities are available for member selection as well as code checking. The following sections describe the salient features of the design approach. Members are proportioned to resist the design loads without exceedance of the capacities. The most economical section is selected on the basis of the least weight criteria. The code checking part of the program also checks the slenderness requirements and the stability criteria. It is generally assumed that the user will take care of the detailing requirements like flange buckling, web crippling etc. Users are recommended to adopt the following steps in performing the steel design: 1) Specify the geometry and factored loads. Perform the analysis. 2) Specify the design parameter values if different from the

default values. 3) Specify whether to perform code checking or member

selection.

Section 4B

Page 248: International Design Codes

Steel Design Per GBJ 17-88 Section 4B 4-12

4B.2 Analysis Methodology

Analysis is done for the primary and combination loading conditions provided by the user. The user is allowed complete flexibility in providing loading specifications and using appropriate load factors to create necessary loading situations. Depending upon the analysis requirements, regular stiffness analysis, P-Delta analysis or Non-linear analysis may be specified. Dynamic analysis may also be performed and the results combined with static analysis results. Please note that STAAD does not automatically factor any loads. The responsibility of creating load combinations with factored loads is entirely upon the user.

4B.3 Member Property Specifications

For specification of member properties, the steel section library available in STAAD may be used. The next section describes the syntax of commands used to assign properties from the built-in steel table. Member properties may also be specified using the User Table facility. For more information on these facilities, refer to the STAAD Program Technical Reference manual.

4B.4 Built-in Chinese Steel Section Library

The following information is provided for use when the built-in steel tables are to be referenced for member property specification. These properties are stored in a database file. If called for, the properties are also used for member design. Since the shear areas are built into these tables, shear deformation is always considered for these members. An example of the member property specification in an input file is provided at the end of this section.

Page 249: International Design Codes

Section 4B 4-13

A complete listing of the sections available in the built-in steel section library may be obtained by using the tools of the graphical user interface. Following are the descriptions of different types of sections. B Shapes These shapes are designated in the following way.

20 TO 30 TA ST I14 33 36 TO 46 TA ST I63C

Channels Channels are specified in the following way.

11 TA ST CH5 17 TA ST CH40C

Double Channels Back to back double channels, with or without a spacing between them, are available. The letter D in front of the section name will specify a double channel.

11 TA D CH22B 17 TA D CH40C SP 0.5

In the above set of commands, member 11 is a back to back double channel CH22B with no spacing in between. Member 17 is a double channel CH40C with a spacing of 0.5 length units between the channels.

Page 250: International Design Codes

Steel Design Per GBJ 17-88 Section 4B 4-14

Angles Two types of specifications may be used to describe an angle. The standard angle section is specified as follows:

16 20 TA ST L25X16X3

The above section signifies an angle with legs of length 25mm and 16mm and a leg thickness of 3 mm. This specification may be used when the local Z axis corresponds to the z-z axis specified in Chapter 2. If the local Y axis corresponds to the z-z axis, type specification "RA" (reverse angle) may be used.

17 21 TA RA L100X80X6

Double Angles Short leg back to back or long leg back to back double angles can be specified by means of input of the words SD or LD, respectively, in front of the angle size. In case of an equal angle, either SD or LD will serve the purpose.

33 35 TA SD L25X16X4 SP 0.6 37 39 TA LD L100X80X6 43 TO 47 TA LD L32X20X3 SP 0.75

Tubes (Rectangular or Square Hollow Sections) Tubes can be assigned in 2 ways. In the first method, the designation for the tube is as shown below. This method is meant for tubes whose property name is available in the steel table. In these examples, members 1 to 5 consist of a 2X2X0.5 inch size tube section, and members 6 to 10 consist of 10X5X0.1875 inch size tube section. The name is obtained as 10 times the depth, 10 times the width, and 16 times the thickness.

Page 251: International Design Codes

Section 4B 4-15

1 TO 5 TA ST TUB20202.5 6 TO 10 TA ST TUB100503.0

In the second method, tubes are specified by their dimensions. For example,

6 TA ST TUBE DT 8.0 WT 6.0 TH 0.5

is a tube that has a height of 8 length units, width of 6 length units, and a wall thickness of 0.5 length units. Only code checking, no member selection, will be performed for TUBE sections specified in this latter manner. Pipes (Circular Hollow Sections) Pipes can be assigned in 2 ways. In the first method, the designation for the pipe is as shown below. This method is meant for pipes whose property name is available in the steel table.

1 TO 5 TA ST PIP180X5 6 TO 10 TA ST PIP273X6.5

In the second method, pipe sections may be provided by specifying the word PIPE followed by the outside and inside diameters of the section. For example,

1 TO 9 TA ST PIPE OD 25.0 ID 20.0

specifies a pipe with outside diameter of 25 length units and inside diameter of 20 length units. Only code checking, no member selection, will be performed on pipes specified in this latter manner.

Page 252: International Design Codes

Steel Design Per GBJ 17-88 Section 4B 4-16

Sample File Containing Chinese Shapes STAAD SPACE UNIT METER KN JOINT COORD 1 0 0 0 12 110 0 0 MEMB INCI 1 1 2 11 UNIT CM MEMBER PROPERTIES CHINESE * B SHAPES 1 TA ST I10 * CHANNELS 2 TA ST CH16A * DOUBLE CHANNELS 3 TA D CH22B SP 1.0 * ANGLES 4 TA ST L25X25X4 * REVERSE ANGLES 5 TA RA L25X16X3 * DOUBLE ANGLES - SHORT LEGS BACK TO BACK 6 TA SD L25X16X3 SP 0.6 * DOUBLE ANGLES - LONG LEGS BACK TO BACK 7 TA LD L32X20X3 SP 0.75 * TUBES (RECTANGULAR OR SQUARE HOLLOW SECTIONS) 8 TA ST TUB50252.5 * TUBES (RECTANGULAR OR SQUARE HOLLOW SECTIONS) 9 TA ST TUBE DT 8.0 WT 6.0 TH 0.5 * PIPES (CIRCULAR HOLLOW SECTIONS) 10 TA ST PIP180X5 * PIPES (CIRCULAR HOLLOW SECTIONS) 11 TA ST PIPE OD 18.0 ID 10.0 PRINT MEMB PROP FINI

Page 253: International Design Codes

Section 4B 4-17

4B.5 Member Capacities

The basic measure of member capacities are the allowable stresses on the member under various conditions of applied loading such as allowable tensile stress, allowable compressive stress etc. These depend on several factors such as cross sectional properties, slenderness factors, unsupported width to thickness ratios and so on. Explained here is the procedure adopted in STAAD for calculating such capacities. Allowable stress for Axial Tension In members with axial tension, the tensile load must not exceed the tension capacity of the member. The tension capacity of the member is calculated on the basis of allowable tensile stresses provided in Table 3.2.1-2 of the code. STAAD calculates the tension capacity of a given member per this allowable stress value and a user supplied net section factor (NSF-a default value of 1.0 is present but may be altered by changing the input value, see Table 1) and proceeds with member selection or code checking. Allowable stress for Axial Compression The allowable stress for members in compression is determined according to Table 3.2.1-2. Compressive resistance is a function of the slenderness of the cross-section (Kl/r ratio) and the user may control the slenderness value by modifying parameters such as KY, LY, KZ and LZ. The provisions of Section 5 are used to check the adequacy of sections in compression. Allowable stress for Bending and Shear Sections subjected to bending moments and shear forces are to be designed according to the provisions of section 5. The permissible bending compressive and tensile stresses are dependent on such factors as outstanding legs and thickness of flanges, unsupported length of the compression flange (UNL, defaults to member length) etc. Shear capacities are calculated according to Table 3.2.1-2 and Section 5 and are a function of web depth, web

Page 254: International Design Codes

Steel Design Per GBJ 17-88 Section 4B 4-18

thickness etc. Users may use a value of 1.0 or 2.0 for the TRACK parameter to obtain a listing of the bending and shear capacities.

4B.6 Combined Loading

For members experiencing combined loading (axial force, bending and shear), applicable interaction formulas are checked at different locations of the member for all modeled loading situations. The procedure of Section 5 is implemented for combined axial load and bending.

4B.7 Design Parameters

The user is allowed complete control over the design process through the use of parameters mentioned in Table 1 of this chapter. These parameters communicate design decisions from the engineer to the program. The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements of an analysis, some or all of these parameter values may have to be changed to exactly model the physical structure.

4B.8 Code Checking

The purpose of code checking is to check whether the provided section properties of the members are adequate. The adequacy is checked per the GBJ 17-88 requirements. Code checking is done using forces and moments at specified sections of the members. If the BEAM parameter for a member is set to 1, moments are calculated at every twelfth point along the beam, and the maximum moment about the major axis is used. When no sections are specified and the BEAM parameter is set to zero (default), design will be based on member start and end

Page 255: International Design Codes

Section 4B 4-19

forces. The code checking output labels the members as PASSed or FAILed. In addition, the critical condition, governing load case, location (distance from start joint) and magnitudes of the governing forces and moments are also printed.

4B.9 Member Selection

The member selection process basically involves determination of the least weight member that PASSes the code checking procedure based on the forces and moments of the most recent analysis. The section selected will be of the same type as that specified initially. For example, a member specified initially as a channel will have a channel selected for it. Selection of members whose properties are originally provided from a user table will be limited to sections in the user table.

Table 4B.1 Chinese Steel Design Parameters

Parameter Default Description Name Value

KY 1.0 K value in local y-axis. Usually, this is the minor axis.

KZ 1.0 K value in local z-axis. Usually, this is the major axis.

LY Member Length

Length in local y-axis to calculate slenderness ratio.

LZ Member Length

Same as above except in z-axis (major).

GRADE 1.0 Grade of steel as explained in Table 3.2.1-2 of Code. The following values represent the various grades of steel: Grade 3 group 1 - 1 Grade 3 group 2 - 2 Grade 3 group 3 - 3 16Mn and 16Mnq - 4 15MnV and 15MnVq - 5

NSF 1.0 Net section factor for tension members.

COMPRESSION 150 Allowable KL/r value in compression.

Page 256: International Design Codes

Steel Design Per GBJ 17-88 Section 4B 4-20

Table 4B.1 Chinese Steel Design Parameters

Parameter Default Description Name Value

TENSION 300 Allowable KL/r value in tension.

MAIN 0.0 0.0 = Check Slenderness ratio against allowable values.

1.0 = Do not check for slenderness.

PFY 1.2 Plasticity adaptation factor for Y direction.

PFZ 1.05 Plasticity adaptation factor for Z direction.

SFY 1.0 Stability factor for Y direction.

SFZ 1.0 Stability factor for Z direction.

TRACK 1.0 1.0 = Print all critical member stresses. 0.0 = Suppress critical member stresses.

DMAX 100.0 cm. Maximum allowable depth.

DMIN 0.0 cm. Minimum allowable depth.

RATIO 1.0 Permissible ratio of the actual to allowable stresses.

BEAM 0.0 0.0 = design only for end moments and those at locations specified by the SECTION command.

1.0 = calculate moments at twelfth points along the beam, and use the maximum, Mz for design.

Sample Input data for Steel Design UNIT METER PARAMETER CODE CHINESE NSF 0.85 ALL GRADE 3.0 MEMBER 7 KY 1.2 MEMBER 3 4 RATIO 0.9 ALL TRACK 1.0 ALL CHECK CODE ALL

Page 257: International Design Codes

Section 5 European Codes

Page 258: International Design Codes
Page 259: International Design Codes

5-1

Concrete Design Per Eurocode EC2

5A.1 Design Operations

STAAD provides a comprehensive set of national codes for the design of concrete structures. In general, all the available codes, including EC2, follow the same procedure for the design of the concrete members. The main steps in performing a design operation are: 1. Selecting the applicable load cases to be considered in the

design process. 2. Providing appropriate parameter values if different from the

default values. 3. Perform the design for the member as appropriate. These operations can be repeated by the user any number of times depending on the design requirements. The parameters referred to above provide the user with the ability to allocate specific design properties to individual members considered in the design operation.

5A.2 Eurocode 2 (EC2)

Eurocode 2, Design of concrete structures, Part 1, General rules and rules for buildings, provides design rules applicable to plain, reinforced or prestressed concrete used in buildings and civil engineering works. It is based on the limit state philosophy common to modern standards.

Section 5A

Page 260: International Design Codes

Concrete Design Per Eurocode EC2 Section 5A 5-2

The objective of this method of design is to ensure that possibility of failure is reduced to a negligible level. This is achieved through application of factors to both the applied loads and the material properties. The code also provides guidelines on the global method of analysis to be used for calculating internal member forces and moments. STAAD provides a number of methods for analysis, allowing Geometric Nonlinearity as well as P-Delta effects to be considered.

5A.3 National Application Documents

Various authorities of the CEN member countries have prepared National Application Documents to be used with EC2. These documents provide alternative factors for loads and may also provide supplements to the rules in EC2. The current version of EC2 implemented in STAAD adheres to the factors and rules provided in EC2 and has not been modified by any National Application Documents.

5A.4 Material Properties and Load Factors

Design resistances are obtained by dividing the characteristic yield strengths, as given in table 2.3 of EC2, by the material partial safety factors γc for concrete and γs for reinforcements. The magnitude in STAAD is 1.5 for concrete and 1.15 for reinforcements. Material coefficients in STAAD take the following default values unless replaced by user's numerical values provided in the input file. Modulus of Elasticity E = 21.71 KN/mm2

Shear Modulus G = E / 2 (1 + v) Poisson's Ratio v = 0.25 Unit weight ρ = 23.56 KN/m3

Page 261: International Design Codes

Section 5A 5-3

The magnitude of design loads is dependent on γF, the partial safety factor for the action under consideration. In STAAD the user is allowed total control in providing applicable values for the factors and their use in various load combinations.

5A.5 Columns

Columns are designed for axial compressive loads and possible moments at the ends of the member. If a particular load case causes tension in the column being designed that load case is ignored, the design proceeds with a warning message given to that affect. All active load cases will be considered in the design and reinforcements are assumed symmetrically arranged in the cross section. The maximum reinforcement calculated after all design load cases have been considered is then reported as the critical required area of reinforcement.

Slender columns are also covered in the design process, the program will make due allowance for the additional moment that has to be considered in the design. Please note that sway type structures are not directly covered in the current implementation of EC2. This effect, however, can be catered for by the P-DELTA analysis option.

5A.6 Beams

Beams are designed for flexure, shear and torsion. For all these actions active load cases are scanned to create appropriate envelopes for the design process. Maximum torsional moment is also identified and incorporated in the design.

Page 262: International Design Codes

Concrete Design Per Eurocode EC2 Section 5A 5-4

Design for flexure

Reinforcement for both positive and negative moments is calculated on the basis of the section properties provided by the user. If the required reinforcement exceeds the maximum allowable then the section size is inadequate and a massage to that effect is given in the output. Parabolic-rectangular stress distribution for the concrete section is adopted and as moment redistribution is not available in STAAD analysis, the limit for N.A to depth ratio is set according to clause 2.5.3.4.2 (5) of the code. If required, compression reinforcement will be provided in order to satisfy the above limits. It is important to know that beams are designed for the flexural moment MZ only. The moment MY is not considered in the design at all. Design for Shear

Shear reinforcement design is based on the standard method mentioned in clause 4.3.2.4.3 where it is assumed the notional strut inclination is constant. Depending on the shear distribution within the member it may be possible that nominal shear reinforcement will be sufficient to cater for the design shear forces. If this is not the case an attempt is made to identify regions where nominal reinforcement is insufficient and appropriate reinforcement is then calculated to cover the excess design shear force. The maximum shear force that can be carried without crushing the concrete is also checked and if exceeded, a message to revise the section size is given in the output file. Design for Torsion

Torsional moments arising as a result of equilibrium requirements need to be designed for at the ultimate limit state. Reinforcement for torsional moments consists of stirrups combined with longitudinal bars. The combined magnitude of shear stress arising from shear forces and torsional moments are checked in order to establish whether the section size is adequate. If section size is inadequate a massage is given in the output file, otherwise, full

Page 263: International Design Codes

Section 5A 5-5

design is carried out and both shear links and longitudinal bars required are calculated and, where necessary, links are combined with the shear force links and printed in a tabulated manner in the output file.

5A.7 Slabs

Slabs can only be designed for if finite elements are used to represent them in the model of the structure. In the main the design follows the same procedure as for flexure except that shear forces are assumed to be resisted without the provision of shear reinforcements. In cases where this may not be the case users must ensure that necessary checks are carried out. The output for the slab design refers to longitudinal reinforcements, which coincides with the local x direction of the element, and, transverse reinforcement, which coincides with the local y direction of the element. Also, reference is made to 'TOP' and BOTT' reinforcement which relates to the element's 'TOP' and 'BOTTOM' as determined from the connectivity of the element. This may not coincide with the slab's actual top and bottom and, if desired, users must ensure this through the numbering scheme of the elements (see figure 1.13 in the STAAD Technical Reference Manual). The design of the slab considers a fixed bar size of 16mm in both directions with the longitudinal bar being the layer closest to the slab exterior faces.

5A.8 Design Parameters

Design parameters communicate specific design decisions to the program. They are set to default values to begin with and may be altered to suite the particular structure. Depending on the model being designed, the user may have to change some or all of the parameter default values. Some parameters are unit dependent and when altered, the new setting must be compatible with the active "unit" specification. Table 5A.1 lists all the relevant EC2 parameters together with description and default values.

Page 264: International Design Codes

Concrete Design Per Eurocode EC2 Section 5A 5-6

5A.9 Parameter Definition Table

Table 5A.1 – Concrete Design Parameters-EC2

Parameter Default Description Name Value

FYMAIN *460 N/mm2 Yield Stress for main reinforcement (For slabs, it is for reinforcement in both directions)

FYSEC *460N/mm2 Yield Stress for secondary reinforcement. Applicable to shear bars in beams

FC * 30N/mm2 Concrete Yield Stress / cube strength

MINMAIN 8mm Minimum main reinforcement bar size Acceptable bar sizes: 6 8 10 12 16 20 25 32 40 50

MINSEC 8mm Minimum secondary bar size a. Applicable to shear reinforcement in beams

CLEAR * 20mm Clearance of reinforcement measured from concrete surface to closest bar perimeter.

MAXMAIN 50mm Maximum required reinforcement bar size Acceptable bars are per MINMAIN above.

SFACE *0.0 Face of support location at start of beam. (Only applicable for shear - use MEMBER OFFSET for bending )

EFACE *0.0 Face of support location at end of beam. (NOTE : Both SFACE & EFACE must be positive numbers.)

TRACK 0.0 0.0 = Critical Moment will not be printed with beam design report. Column design gives no detailed results.

1.0 = For beam gives min/max steel % and spacing. For columns gives a detailed table of output with additional moments calculated.

2.0 = Output of TRACK 1.0 List of design sag/hog moments and corresponding required steel area at each section of member

MMAG 1.0 Factor by which column design moments are magnified

Page 265: International Design Codes

Section 5A 5-7

Table 5A.1 – Concrete Design Parameters-EC2

Parameter Default Description Name Value

NSECTION 10 Number of equally-spaced sections to be considered in finding critical moment for beam design. The upper limit is 20.

WIDTH *ZD Width of concrete member. This value default is as provided as ZD in MEMBER PROPERTIES.

DEPTH *YD Depth of concrete member. This value default is as provided as YD in MEMBER PROPERTIES.

BRACE 0.0 0.0 = Column braced in both directions. 1.0 = Column unbraced about local Z direction

only 2.0 = Column unbraced about local Y

direction only 3.0 = Column unbraced in both Y and Z

directions

ELY 1.0 Member length factor about local Y direction for column design.

ELZ 1.0 Member length factor about local Z direction for column design.

SRA 0.0 0.0 = Orthogonal reinforcement layout without considering torsional moment Mxy -slabs only

-500 = Orthogonal reinforcement layout with Mxy used to calculate WOOD & ARMER moments for design.

A = Skew angle considered in WOOD & ARMER equations where A is the angle in degrees.

SERV 0.0 0.0 = No serviceability check performed. 1.0 = Perform serviceability check for beams

as if they were continuous. 2.0 = Perform serviceability check for beams

as if they were simply supported. 3.0 = Perform serviceability check for beams

as if they were cantilever beams. * Provided in current unit system

Page 266: International Design Codes

Concrete Design Per Eurocode EC2 Section 5A 5-8

Page 267: International Design Codes

5-9

Steel Design Per Eurocode EC3

5B.1 General Description

Introduction STAAD provides a comprehensive set of national codes for the design of steel structures. In general, all the available codes, including EC3, follow the same procedure to perform either code-check of members or select optimum cross sections for members of an analyzed structure.

The main steps in performing a design operation are:

1. Selecting the applicable load cases to be

considered in the design process.

2. Providing appropriate parameter values if different from the default values.

3. Specify whether to perform code-checking and/or member selection.

These operations can be repeated by the user any number of times depending on the design requirements.

The parameters, referred to above, provide the user with the ability to allocate specific design properties to individual members considered in the design operation.

Section 5B

Page 268: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-10

Eurocode (EC3)

Eurocode 3, Design of steel structures, Part 1.1 General rules and rules for buildings (EC3) provides design rules applicable to structural steel used in buildings and civil engineering works. It is based on the limit states philosophy common to modern standards. The objective of this method of design is to ensure that possibility of failure is reduced to a negligible level. This is achieved through application of factors to both the applied loads and the material properties. The code also provides guidelines on the global method of analysis to be used for calculating internal member forces and moments. STAAD uses the elastic method of analysis which may be used in all cases. Also there are three types of framing referred to in EC3. These are “Simple”, “Continuous”, and “Semi-continuous” which reflect the ability of the joints in developing moments. In STAAD, only “Simple” and “Continuous” joint types can be assumed when carrying out global analysis. Axes convention in STAAD and EC3

By default, STAAD defines the major axis of the cross-section as zz and the minor axis as yy. A special case where zz is the minor axis and yy is the major axis is available if the “SET Z UP” command is used and is discussed in the Technical Reference Manual. The longitudinal axis of the member is defined as x and joins the start joint of the member to the end with the same positive direction. EC3, however, defines the principal cross-section axes in reverse to that of STAAD, but the longitudinal axis is defined in the same way. Both of these axes definitions follow the orthogonal right hand rule. See figure below. Users must bear this difference in mind when examining the code-check output from STAAD.

Page 269: International Design Codes

Section 5B 5-11

STAAD EC3

Figure 1 Axes Convention in STAAD and EC3. National Application Documents

Various authorities of the CEN member countries have prepared National Application Documents to be used with EC3. These documents provide alternative factors for loads and may also provide supplements to the rules in EC3. The current version of EC3 implemented in STAAD adheres to the factors and rules provided in EC3 and has not been modified by any National Application Documents. Section Classification

The occurrence of local buckling of the compression elements of a cross-section prevents the development of full section capacity. It is therefore imperative to establish this possibility prior to determining the section capacities. Cross sections are classified in accordance with their geometrical properties and the stress pattern on the compression elements. For each load case considered in the design process, STAAD determines the section class and calculates the capacities accordingly. Material Properties and Load Factors

Design resistances are obtained by dividing the characteristic yield strength, as given in table 3.1, by the material partial safety factor gm. The magnitude of gm in STAAD is 1.1 which is applicable to all section types.

Page 270: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-12

Material coefficients in STAAD take the following default values unless replaced by user’s numerical values provided in the input file. Modulus of Elasticity E = 205 N/mm2

Shear Modulus G = E / 2 (1+v) Poisson’s Ratio v = 0.3 Unit weight r = 76.8 KN/m3

The magnitude of design loads is dependent on gf, the partial safety factor for the action under consideration. In STAAD, the user is allowed total control in providing applicable values for the factors and their use in various load combinations. Axially Loaded Members

For members subject to tension loads only, tension capacity is calculated based on yield strength, material factor gm and cross-sectional area of the member with possible reduction due to bolt holes. When bolt holes need to be considered in the capacity calculations, the value used for gm is 1.2 and the yield strength is replaced with the ultimate tensile strength of the material. The tension capacity is then taken as the smaller of the full section capacity and the reduced one. For members subject to compression only, cross-section resistance as well as buckling resistance must be checked. The latter is often more critical as it is influenced by a number of factors including the section type and member unbraced length. Beams

The main requirement for a beam is to have sufficient cross-section resistance to the applied bending moment and shear force. Also the possibility of lateral-torsional buckling must be taken into consideration when the full length of the member is not laterally restrained. The bending capacity is primarily a function of the section type and the material yield strength. There are four classes of cross-

Page 271: International Design Codes

Section 5B 5-13

sections defined in EC3. Class 1 and 2 sections can both attain full plastic capacity with the exception that the class 2 sections cannot sustain sufficient rotation required for plastic analysis of the model. Class 3 sections, due to local buckling, cannot develop plastic moment capacity and the yield stress is limited to the extreme compression fiber of the section. The elastic section modulus is used to determine the moment capacity. Class 4 sections do suffer from local buckling and explicit allowance must be made for the reduction in section properties before the moment capacity can be determined. Further, because of interaction between shear force and bending moment, the moment resistance of the cross-section may be reduced. This, however, does not occur unless the value of applied shear forces exceeds 50% of the plastic shear capacity of the section. In such cases the web is assumed to resist the applied shear force as well as contributing towards the moment resistance of the cross-section. The plastic shear capacity is calculated using the appropriate shear

area for the section and the yield strength in shear, taken as 3

fy .

As mentioned earlier, lateral-torsional buckling must also be considered whenever the full length of the member is not laterally restrained. The buckling capacity is dependent on the section type as well as the unrestrained length, restraint conditions and type of applied loading. Axially Loaded Members With Moments

The bending resistance of members subject to coexistent axial load is reduced by the presence of the axial load. The presence of large shear, as mentioned above, can also reduce the bending resistance of the section under consideration. If the shear load is large enough to cause a reduction in bending resistance, then the reduction due to shear has to be taken into

Page 272: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-14

account before calculating the effect of the axial load on the bending resistance of the section. Generally, EC3 requires to check cross-section resistance for local capacity and also check the overall buckling capacity of the member. In the case of members subject to axial tension and bending, there is provision to take the stabilizing effect of the tension load into consideration. This is achieved by modifying the extreme compression fiber stress and calculating an effective applied moment for the section. This is then checked against the lateral-torsional buckling resistance of the section.

5B.2 Design Parameters

Introduction Design parameters communicate specific design decisions to the program. They are set to default values to begin with and may be altered to suite the particular structure. Depending on the model being designed, the user may have to change some or all of the parameter default values. Some parameters are unit dependent and when altered, the new setting must be compatible with the active “unit” specification. Table 5B.1 lists all the relevant EC3 parameters together with description and default values.

Page 273: International Design Codes

Section 5B 5-15

Parameter Definition Table

Table 5B.1 – Steel Design Parameters EC3

Parameter Default Definition Name Value

KY 1.0 K factor in local y axis.

KZ 1.0 K factor in local z axis.

LY Member Length Compression length in local y axis, Slenderness ratio = (KY)*(LY)/(Ryy)

LZ Member Length Compression length in local z axis, Slenderness ratio = (KZ)*(LZ)/(Rzz)

UNL Member Length Unrestraint length of member used in calculating the lateral-torsional resistance moment of the member.

PY Yield Strength The yield strength default value is set based on the default value of the “SGR” parameter.

NSF 1.0 Net tension factor for tension capacity calculation.

SGR 0.0 Steel grade as per table 3.1 in EC3. 0.0 = Fe 360 1.0 = Fe 430 2.0 = Fe 510

SBLT 0.0 Indicates if the section is rolled or built-up. 0.0 = Rolled 1.0 = Built-up.

CMM 1.0 Indicates type of loading on member. Can take a value from 1 to 6. Refer to Table 5B.2 for more information on its use.

CMN 1.0 Indicates the level of End-Restraint. 0 1.0 = No fixity 0.5 = Full fixity

0.7 = One end free and other end fixed

DMAX 100.0 cm Maximum allowable depth for the member.

DMIN 0 Minimum required depth for the member.

RATIO 1 Permissible ratio of loading to capacity.

BEAM 0 Indicates the number of sections to be checked for during the design.

= Check the end sections only or the locations specified by the SECTION command.

Page 274: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-16

Table 5B.1 – Steel Design Parameters EC3

Parameter Default Definition Name Value

= Consider 13 sections along the member and select the maximum Mz location for the design check.

= Same as BEAM = 1.0 but checks the end sections of the member as well.

= Consider 13 sections along the member and design check every section.

CODE Undefined User must specify EC3.

TRACK 0 Controls the level of descriptivity of output. 0 = Minimum 1 = Intermediate 2 = Maximum 4 = option 4 for performing a deflection check

UNF 1.0 Unsupported buckling length as a factor of the beam length

LEG 0.0 Connection type

LVV Maximum of Lyy and Lzz

(Lyy is a term used by BS5950)

Buckling length for angle about its principle axis

FU Ultimate tensile strength of steel

DFF None (Mandatory for

deflection check)

Deflection limit

DJ1 Start Joint of member

Joint No. denoting starting point for calculation of "Deflection Length"

DJ2 End Joint of member

Joint No. denoting end point for calculation of "Deflection Length"

Page 275: International Design Codes

Section 5B 5-17

Notes: 1. LEG - Table 25 BS5950 for Fastener Control

The slenderness of single and double angle, channel and tee sections are specified in BS 5950 table 25 depending on the connection provided at the end of the member. To define the appropriate connection, a LEG parameter should be assigned to the member. The following table indicates the value of the LEG parameter required to match the BS5950 connection definition:- Clause LEG

short leg 1.0 (a) - 2 bolts long leg 3.0 short leg 0.0

4.7.10.2 Single Angle (b) - 1 bolt

long leg 2.0

short leg 3.0 (a) - 2 bolts long leg 7.0 short leg 2.0 (b) - 1 bolt long leg 6.0 long leg 1.0 (c) - 2 bolts short leg 5.0 long leg 0.0

4.7.10.3 Double Angle

(d) - 1 bolt short leg 4.0

(a) - 2 or more rows of bolts 1.0 4.7.10.4

Channels (b) - 1 row of bolts 0.0

(a) - 2 or more rows of bolts 1.0 4.7.10.5 Tee Sections (b) - 1 row of bolts 0.0

Page 276: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-18

For single angles, the slenderness is calculated for the geometric axes, a-a and b-b as well as the weak v-v axis. The effective lengths of the geometric axes are defined as:- La = KY * KY Lb = KZ * LZ The slenderness calculated for the v-v axis is then used to calculate the compression strength pc for the weaker principal axis (z-z for ST angles or y-y for RA specified angles). The maximum slenderness of the a-a and b-b axes is used to calculate the compression strength pc for the stronger principal axis. Alternatively for single angles where the connection is not known or Table 25 is not appropriate, by setting the LEG parameter to 10, slenderness is calculated for the two principal axes y-y and z-z only. The LVV parameter is not used. For double angles, the LVV parameter is available to comply with note 5 in table 25. In addition, if using double angles from user tables, (Technical Reference Manual section 5.19) an eleventh value, rvv, should be supplied at the end of the ten existing values corresponding to the radius of gyration of the single angle making up the pair.

2. BEAM

Ensure that the “BEAM” parameter is set to either 1 or 2 while performing code checking for members susceptible to Lateral - Torsional Buckling.

Page 277: International Design Codes

Section 5B 5-19

Table 5B.2

Page 278: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-20

5B.3 Worked Examples

Example 1: Restrained simply supported beam.

The figure below shows a simply supported beam spanning 7 meters and assumed to be fully restrained laterally. Fe 430 steel is assumed and the beam will be checked to the clauses of EC3 currently implemented in STAAD.

Unfactored Loading Permanent Load: UDL including selfweight assume 20 KN/m Variable Load: UDL load assume 25 KN/m Partial safety factor for permanent load (ULS) 1.35 Partial safety factor for variable load (ULS) 1.5 Factored Load: 1.35 X 15 + 1.5 X 25 = 64.5 KN/m 64.5 KN/m

Page 279: International Design Codes

Section 5B 5-21

Try 457 X 191 X 82UB. h = 460.2 mm d = 407.9mm tw = 9.9 mm b = 191.3 mm tf = 16.0 mm A = 104.5cm2

ly = 37103 cm4 Wpl.y = 1833 cm3 Av

= 48.13 cm2

Grade Fe 430 Fy = 275 N/mm2

Section Classification Outstand Flanges in Compression, limit for rolled section c/t = 10e = 9.2 c/t ratio for the selected section is 95.65/16 = 5.9 < 9.2 Flange is therefore a class 1 element. Web with N.A. at mid depth, limit for rolled section d/tw = 72e = 66.6 d/ tw ratio for the selected section is 407.9/9.9 = 41.2 < 66.6 Web is therefore a class 1 element.

Shear Resistance Maximum design shear force (64.5 X 7) / 2 = 225.7 KN Plastic shear resistance Vpl.Rd = (Av / gM0) (fy / 3 ) = (4813 / 1.1) (275 / 1.732) / 1000 = 694.7 KN Maximum design shear force = 225.7 KN < 694.7 KN Therefore shear resistance is satisfactory.

Section is class 1

Page 280: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-22

Moment Resistance Maximum design moment at mid-span of beam (wl2 / 8) = 395 Knm Maximum resistance of section Mc.Rd = ( Wpl.yfy) / gM0 = (1833 X 103 X 275) / (1.1 X 106) = 458.2KNm

Lateral Torsional Buckling As it is assumed that the full length of member is restrained laterally there is no need to check for Lateral Torsional Buckling of the member.

Maximum design moment = 395 KNm < 458.2 KNm Therefore moment resistance is satisfactory.

457 X 191 X 82 UB In Fe 430 Steel is satisfactory.

Page 281: International Design Codes

Section 5B 5-23

Example 2: Unrestrained simply supported beam. Figure 2 shows a simply supported beam spanning 5 meters and assumed to be laterally unrestrained. Fe 430 steel is assumed and the beam will be checked to the clauses of EC3 currently implemented in STAAD.

5m Unfactored Loading Permanent Load: UDL including selfweight assume 15 KN/m Variable Load: UDL load assume 20 KN/m Partial safety factor for permanent load (ULS) 1.35 Partial safety factor for variable load (ULS) 1.5 Factored Load: 1.35 X 15 + 1.5 X 20 = 50.3 KN/m 50.3 KN/m

5m

Page 282: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-24

Try 457 X 191 X 82 UB. h = 460.2 mm d = 407.9 mm tw = 9.9 mm b = 191.3 mm tf = 16.0 mm A = 104.5 cm2 ly = 37103cm4 Wpl.y = 1833cm3 Av = 48.13cm2 Grade Fe 430fy = 275 N/mm2

Section Classification Outstand Flanges in compression, limit for rolled section c/t = 10e = 9.2 c/t ratio for the selected section is 95.65/16 = 5.9 < 9.2 Flange is therefore a class 1 element. Web with N.A. at mid depth, limit for rolled section d/tw = 72e = 66.6 d/ tw ratio for the selected section is 407.9/9.9 = 41.2 < 66.6 Web is therefore a class 1 element.

Shear Resistance Maximum design shear force (50.3 X 5) / 2 = 120.8 KN Plastic shear resistance Vpl.Rd = (Av / gM0) (fy / 3 ) = (4813 / 1.1) (275 / 1.732) / 1000 = 694.7 KN Maximum design shear force = 120.8 KN < 694.7 KN Therefore shear resistance is satisfactory.

Section is class 1

Page 283: International Design Codes

Section 5B 5-25

Moment Resistance Maximum design moment at mid-span of beam (wl2 / 8) = 157.2 KNm Maximum resistance of section Mc.Rd = ( Wpl.yfy) / gM0 = (1833 X 103 X 275) / (1.1 X 106) = 458.2KNm

Lateral Torsional Buckling Buckling resistance moment Mb.Rd = XLTbwWPl.yfy / gM1 bw = 1 for Class 1 or Class 2 sections.

XLT = 0.5LT

2LT

2LT ]l[ff

1−+

fLT = 0.5 [1 + aLT( lLT – 0.2 ) + l2

LT ] aLT = 0.21 for rolled sections. lLT = [ lLT / l1 ] [bw]0.5

l1 = 93.9e lLT is the geometrical slenderness ratio for lateral-torsional buckling.

lLT = /25.66])(L/a[1)(C

L/i2

LT0.5

1

LT

+

aLT = ( Iw / lt ) 0.5

Maximum design moment = 157.2 KNm < 458.2 KNm Therefore moment resistance is satisfactory.

Page 284: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-26

lw = lzhs2 / 4

hs = h - tf

iLT = [lzIw / Wpl.y2]0.25

C1 is a factor depending on transverse loading type. For the selected section: hs = 460.2 – 16.0 = 444.2 mm lw = 1871 X 44.422 / 4 = 922934.6 cm6

iLT = [1871 X 922934.6 / (18332) ]0.25 = 4.76 cm aLT = ( 922934.6 / 69.2 ) 0.5 = 115.4 cm C1 = 1.132 (From EC3 Table F.1.2)

lLT = 0.2520.5 /25.66])(500/115.4[11.132

500/4.76+

= 86.06

l1 = 93.9 (235 / 275)0.5 86.8 lLT = 86.06 / 86.8 0.99 fLT = 0.5 [1 + 0.21 (0.99 – 0.2) + 0.992] 1.07 XLT = 1 / { 1.07 + [ 1.072 – 0.992 ] 0.5} 0.67 Mb.Rd = 0.67 X 1 X 1833 X 103 X 275 / 1.1 X 106

Mb.Rd = 307.0 KNm

Maximum design moment = 157.2 KNm < 307.0 KNm Therefore buckling resistance moment is satisfactory.

Page 285: International Design Codes

Section 5B

5-27

Example 3: Axially Loaded Column. Figure 3 shows a pinned end column 5m long subject to a factored load of 3500 kN. Fe 430 steel is assumed and the column will be checked to the clauses of EC3 currently implemented in STAAD. 5m 3500 KN Try 305 X 305 X 158 UC h = 327.2 mm d = 246.6 mm tw = 15.7 mm b = 310.6 mm tf = 25.0 mm A = 210.2 cm2

iy = 13.9 cm iz = 7.89 cm fy = 275 N/ mm2

Section Classification Outstand flanges in compression, limit for rolled section c/t = 10e = 9.2 c/t ratio for the selected section is 155.3/25 = 6.21 < 9.2 Flange is therefore a class 1 element.

3500 KN

Page 286: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-28

Web with N.A. at mid depth, limit for rolled section d/tw = 33e = 30.5 d/ tw ratio for the selected section is 246.6/15.7 = 15.7 < 30.5 Web is therefore a class 1 element.

Compressive resistance Design compression resistance of the cross-section, Nc.Rd = ( Afy) / gM0 Nc.Rd = ( 210.2 X 102 X 275 ) / ( 1.1 X 103 ) Nc.Rd = 5255 KN

Buckling resistance The design buckling resistance of the member Nb.Rd = XbAAfy / gM0 bA = 1 for class 1, 2 or 3 cross-sections. X is a reduction factor for the relevant buckling mode.

X = 5.0

2_2 ]lf[f

1

−+

f = 0.5 [ 1 + a ( – 0.2) + ] a is an imperfection factor.

= [ l / l1 ] [ bA ]0.5

l is the slenderness for the relevant buckling mode.

Section is class 1

Applied design load NSd = 3500 KN < 5255 Therefore compression resistance is satisfactory.

_l

2_l

_l

Page 287: International Design Codes

Section 5B 5-29

l1 = 93.9 e From table 5.5.3 for buckling about y-y-axis, a is 0.34. From table 5.5.3 for buckling about z-z axis, a is 0.49. ly = 500 / 13.9 ly = 35.97 lz = 500 / 7.89 lz = 63.37 Consider buckling about the y-y axis.

= [ ly / l1] [bA]0.5

l1 = 93.9 X 0.924 = 86.8

= [35.9 / 86.8 ] = 0.41

fy = 0.5 [1 + ay – 0.2) + l2y]

fy = 0.5 [1 + 0.34 (0.41 – 0.2) + 0.412] fy = 0.62

Xy =

_l y

_l y

(_l y

0.5y

2_y

2y ]l[ff

1

−+

= 0.522 ]0.41[0.620.62

1−+

Xy = 0.92 but cannot be greater than 1, therefore Xy = 0.92. Nb.Rdy = XyAfy / gM0 = (0.92 X 275 X 201.2 X 102) / (1.1 X 103)

= 4627KN

Page 288: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-30

Consider buckling about the z-z axis.

= [ lz / l1] [bA]0.5

l1 = 93.9 X 0.924 = 86.8

= [63.37 / 86.8 ] = 0.73

fz = 0.5 [1 + az – 0.2) + ] fz = 0.5 [1 + 0.49 (0.73 – 0.2) + 0.732] fz = 0.89

Xz =

_l z

_l z

(_l z

2_l z

5.0z

2_z

2z ]lf[f

1

−+

= 0.522 ]0.73[0.890.891−+

Xz = 0.71 but cannot be greater than 1, therefore Xz = 0.71. Nb.Rdz = XzAfz / gM0 = (0.71 X 275 X 201.2 X 102) / (1.1 X 103)

= 3571KN

3400 KN design load is less than 3571 KN, therefore section is satisfactory.

Page 289: International Design Codes

Section 5B 5-31

Example 4: Column subject to axial load and bending The figure below shows a pinned end column 5m long subject to a factored load of 1500 KN and factored bending moment of 250 KNm about the major axis. Fe 430 steel is assumed and the column will be checked to the clauses of EC3 currently implemented in STAAD.

Try 305 X 305 X 137 UC h = 320.5 mm d = 246.6 mm tw = 13.8 mm b = 308.7mm tf = 21.7 mm A = 174.6cm2

Wpl.y = 2298cm3 Wel.y= 2049 cm3 Av = 50.6 cm2

iy = 13.7 cm iz = 7.82 cm fy = 275 N/mm2

Page 290: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-32

Section classification

Shear Resistance Maximum design shear force 250 / 5 = 50 KN Plastic shear resistance Vpl.Rd = ( Av / gM0 ) ( fy / 3 ) = (5060 / 1.1) (275 / 1.732) / 1000 = 730 KN

Moment Resistance Design bending moment must not exceed the reduced plastic resistance moment of the section given by the following equations. MNy.Rd = Mpl.y.Rd ( 1 – n ) / ( 1 – 0.5 a ) a = ( A – 2btf ) / A but ‘a’ must not exceed 0.5. n = Nsd / Npl.Rd

If ‘n’ does not exceed ‘a’ then MNy.Rd = Mpl.y.Rd a = ( 17460 – 2 X 308.7 X 21.7 ) / 17460 a = 0.232 Npl.Rd = ( 275 X 17460 ) ( 1.1 X 1000 ) = 4365 KN n = 1500 / 4365 = 0.343

Section by inspection is class 1.

Design shear force is less than 730 KN. Shear resistance is satisfactory.

Page 291: International Design Codes

Section 5B 5-33

Mpl.y.Rd = ( 275 X 2298 ) / ( 1.1 X 1000 ) = 574.5 KN MNy.Rd = 574.5 ( 1 – 0.343 ) / ( 1 – 0.5 X 0.232 ) MNy.Rd = 426.97 KNm

Flexural Buckling and Bending Check Members subject to axial load and bending must satisfy:

/gM1AfXN

ymin

sd + /gM1fW

MK

ypl.y

y.sdy ≤ 1

Ky = 1 - yy

sdy

AfXNm

but Ky ≤ 1.5

my = (2bMy – 4) + _l y

el.y

el.ypl.y

WWW −

but my ≤ 0.90

Xmin is the lesser of Xy and Xz, where Xy and Xz are reduction factors as calculated in the previous example. bMy is equivalent moment factor for flexural buckling. From Figure 5.5.3 in EC3, bMy = 1.8 – 0.7 y but in this example, y = 0.0 bMy = 1.8

The design bending moment is less than the reduced moment capacity. The section therefore has sufficient moment resistance.

Page 292: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-34

Consider buckling about the y-y axis.

= [ ly / l1] [bA]0.5 bA = 1.0 for class 1 sections. l1 = 93.9 X 0.924 = 86.8 ly = [500 / 13.7 ] = 36.5

= [36.5 / 86.8 ] = 0.42

fy = 0.5 [1 + ay – 0.2) + l2y]

fy = 0.5 [1 + 0.34 (0.42 – 0.2) + 0.422] fy = 0.62

Xy =

_l y

_l y

(_l y

0.5y

2y

2y ]l[ff

1−+

= 0.522 ]0.42[0.620.621−+

Xy = 0.93 but ≤ 1, therefore Xy = 0.93. Consider buckling about the z-z axis.

= [ lz / l1] [bA]0.5 bA = 1.0 for class 1 sections. l1 = 93.9 X 0.924 = 86.8 lz = [500 / 7.82 ] = 63.9

= [63.9 / 86.8] = 0.73

fz = 0.5 [1 + az – 0.2) + z] fz = 0.5 [1 + 0.49 (0.73 – 0.2) + 0.732] fz = 0.89

_l z

_l z

(_l z

_l 2

Page 293: International Design Codes

Section 5B 5-35

0.5z

2_z

2z ]l[ff

1

−+

= 0.522 ]0.73[0.890.89

1−+

Xz =

Xz = 0.71 but ≤ 1, therefore Xz = 0.71. Xmin is therefore 0.71.

y = 0.42

my = 0.42 (2 X 1.8 – 4) +

_l

204920492298 − = - 0.046

Ky = 1 - X2750.93X17.46

0.046X1500− = 1.015 ≤ 1.5

/gM1AfXN

ymin

sd + /gM1fW

MK

ypl.y

y.sdy ≤ 1

X275/1.10.71X17.461500 +

1.12.298X275/1.015X250 = 0.92 ≤ 1

Members for which lateral-torsional buckling is a potential problem must also satisfy:

/gM1AfXN

yz

sd + /gM1fWX

MK

ypl.yLT

y.sdLT ≤ 1

KLT = 1 - yz

sdLT

AfXNm

but KLT ≤ 1

mLT = 0.15 lzbM.LT – 0.15, but mLT ≤ 0.90 Using the equations used in Example 2, we have the following.

Page 294: International Design Codes

Steel Design Per Eurocode EC3 Section 5B

5-36

For the selected selection: iLT = 8.33 cm aLT = 97.6 cm C1 = 1.879 (From EC3 Table F.1.2)

lLT = 0.2520.5 /25.66](500/97.6)[11.879

500/8.33+

= 36.71

l1 = 93.9 (235 / 275)0.5 = 86.8 lLT = 36.71 / 86.8 = 0.42 fLT = 0.5 [ 1 + 0.21 (0.42 – 0.2) + 0.422 ] = 0.61 XLT = 1 / { 0.61 + [ 0.612 – 0.422 ]0.5 } = 0.95 bMLT = 1.8 lz = 0.73 mLT = 0.15 X 0.73 X 1.8 – 0.15 = 0.047

KLT = 1 - X2750.71X17.46

0.047X1500 = 0.98

/gM1AfXN

yz

sd + /gM1fWX

MK

ypl.yLT

y.sdLT ≤ 1

X275/1.10.71X17.461500 +

X275/1.10.95X2.2980.98X250 = 0.932

305X305X137UC is therefore satisfactory.

Page 295: International Design Codes

Section 5B 5-37

5B.4 User’s Examples Example 1. The following input file is for the single beam in example 1. Only code check related output is enclosed. STAAD PLANE INPUT FILE FOR EX.1 IN THE EC3 MANUAL. INPUT WIDTH 79 UNIT METER KNS JOINT COORDINATES

1 0.000 0.000 0.000 2 5.000 0.000 0.000 MEMBER INCIDENCES 1 1 2 MEMBER PROPERTY BRITISH 1 TABLE ST UB457X191X82 CONSTANTS E STEEL ALL SUPPORTS 1 PINNED 2 FIXED BUT FX MZ LOAD 1 MEMBER LOAD 1 UNI GY-20.0 LOAD 2 MEMBER LOAD 1 UNI GY -25.0 LOAD COMBINATION 3 1 1.35 2 1.5 PERFORM ANALYSIS LOAD LIST 3 PARAMETER CODE EC3 UNL 0.0 ALL BEAM 2.0 ALL TRACK 2 .ALL SGR 1 .ALL CHECK CODE ALL FINISH

Page 296: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-38

Page 297: International Design Codes

Section 5B 5-39

Example 2. The following input file is for the beam in example 2. Only code check related output is enclosed. STAAD PLANE INPUT FILE FOR EXAMPLE 2 INPUT WIDTH 79 UNIT METER KNS JOINT COORDINATES

1 0.000 0.000 0.000 2 5.000 0.000 0.000 MEMBER INCIDENCES 1 1 2 MEMBER PROPERTY BRITISH 1 TABLE ST UB457X191X82 CONSTANTS E STEEL ALL SUPPORTS 1 PINNED 2 FIXED BUT FX MZ LOAD 1 MEMBER LOAD 1 UNI GY -15.0 LOAD 2 MEMBER LOAD 1 UNI GY -20.0 LOAD COMBINATION 3 1 1.35 2 1.5 PERFORM ANALYSIS LOAD LIST 3 PARAMETER CODE EC3 BEAM 2.0 ALL TRACK 2. ALL SGR 1. ALL CHECK CODE ALL FINISH

Page 298: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-40

Page 299: International Design Codes

Section 5B 5-41

Example 3. The following input file is for the simple column in example 3. Only code check related output is enclosed. STAAD PLANE INPUT FILE FOR EXAMPLE 3. UNIT METER KNS JOINT COORDINATES 1 0 0 0 2 0 5 0 MEMBER INCIDENCES 1 1 2 MEMBER PROPERTIES BRITISH 1 TA ST UC305X305X158 CONSTANTS E STEEL ALL SUPPORT 1 FIXED LOAD 1 JOINT LOAD 2 FY -3500 PERFORM ANALYSIS PARAMETERS CODE EC3 TRACK 2.0 ALL SGR 1. ALL CHECK CODE ALL FINISH

Page 300: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-42

Page 301: International Design Codes

Section 5B 5-43

Example 4. The following input file is for the column in example 4. Only code check related output is enclosed. STAAD PLANE INPUT FILE FOR EXAMPLE 4. UNIT METER KNS JOINT COORDINATES 1 0 0 0 2 0 5 0 MEMBER INCIDENCES 1 1 2 MEMBER PROPERTIES BRITISH 1 TA ST UC305X305X137 CONSTANTS E STEEL ALL SUPPORT 1 PINNED 2 FIXED BUT FY MZ LOAD 1 JOINT LOAD 2 FY -1500 2 MZ 250 PERFORM ANALYSIS PARAMETERS CODE EC3 BEAM 2.0 ALL TRACK 2.0 ALL CMM 6 SGR 1.0 ALL CHECK CODE ALL FINISH

Page 302: International Design Codes

Steel Design Per Eurocode EC3 Section 5B 5-44

Page 303: International Design Codes

5-45

Timber Design Per EC 5: Part 1-1. (BS EN 1995-1-1:2004)

5C.1 General Comments

The Timber Design facility as per EC5 in STAAD is based on the European Standard Eurocode 5: Design of Timber Structures - Part 1-1 - General - Common rules and rules for buildings. Principles of Limit States Design of Timber Structures are adopted as specified in the code. The application is limited to the PRISMATIC rectangular shapes only. There is no Eurocode-specific timber section database / library consisting of pre-defined shapes for analysis or for design. The feature of member selection is thus not applicable to this code. The design philosophy of this specification is based on the concept of limit state design. Structures are designed and proportioned taking into consideration the limit states at which they would become unfit for their intended use. Two major categories of limit-state are recognized - ultimate and serviceability. The primary considerations in ultimate limit state design are strength and stability, while that in serviceability is deflection. Appropriate load and resistance factors are used so that a uniform reliability is achieved for all timber structures under various loading conditions and at the same time the chances of limits being surpassed are acceptably remote. In the STAAD implementation, members are proportioned to resist the design loads without exceeding the limit states of strength, stability and serviceability. Accordingly, the most economic section is selected on the basis of the least weight criteria as augmented by the designer in specification of allowable member depths, desired section type, or other such parameters. The code

Section 5C

Page 304: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C

5-46

checking portion of the program checks whether code requirements for each selected section are met and identifies the governing criteria. The following sections describe the salient features of the STAAD implementation of EC 5. A detailed description of the design process along with its underlying concepts and assumptions is available in the specification document. Axes convention in STAAD and EC5 STAAD defines the major axis of the cross-section as zz and the minor axis as yy. The longitudinal axis of the member is defined as x and joins the start joint of the member to the end with the same positive direction. EC5, however, defines the principal cross-section axes in reverse to that of STAAD, but the longitudinal axis is defined in the same way. Both of these axes definitions follow the orthogonal right hand rule. See figure 1 below:

y z

z y

STAAD EC5

Figure 1 Axes convention in STAAD and EC5

z y y

z

Page 305: International Design Codes

Section 5C 5-47

Determination of Factors (A) Kmod – Modification factor taking into account of Load-

duration (LDC) and Moisture-content (Service Class - SCL). Reference Table 3.1 of EC-5-2004. For “Solid Timber”, the values are incorporated in the program.

(B) γm – Partial factor for Material Property values. Reference Table 2.3 of EC-5-2004. For “Solid Timber”, the value of γm (= 1.3) is incorporated in the program.

(C) Kh – Size Factor. For members, subjected to tension, whose maximum c/s

dimension is less than the reference width in tension the characteristic strength in tension (ft0k) is to be increased by the factor Kh.

For members, subjected to bending, whose depth is less

than reference depth in bending, the characteristic strength in bending (fmk) is to be increased by the factor Kh.

As per clause 3.2(3) of EC 5- 2004, for rectangular solid timber with a characteristic timber density ρk ≤ 700 kg/m3 the reference depth in bending or the reference width (maximum cross-sectional dimension) is 150 mm.

The value of Kh = Minimum of {(150/h) 0.2 and 1.3) for

such solid timber is incorporated in the software. Please refer clause numbers 3.3 and 3.4 for the value of Kh for Glued laminated timber and Laminated veener lumber respectively.

Page 306: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-48

(D) KC90 – Factor taking into account the load configuration, possibility of splitting and degree of compressive deformation. For members, subjected to compression, perpendicular to the direction of grain alignment, this factor should be taken into account. Default value of 1 is used in STAAD.Pro. User may override the value. Please refer clause 6.1.5 of EC-5-2004 in this regard.

(E) Km – Factor considering re-distribution of bending

stress in cross section.

For members, subjected to bending, this factor is taken into account for stress checking. For rectangular section the value of Km is 0.7, and this value is incorporated in STAAD.Pro. User may override the value. Please refer clause 6.1.6 of EC-5-2004 in this regard.

(F) Kshape – Factor depending on shape of cross section.

For members, subjected to torsional force, design torsional stress should be less than equal design shear strength multiplied by the factor Kshape. This factor is determined by STAAd.Pro internally using the guidelines of clause 6.1.8 of EC-5-2004 .

Page 307: International Design Codes

Section 5C 5-49

5C.2 Analysis Methodology

Symbols Description

St0d Design tensile stress parallel (at zero degree) to grain

alignment. St90d Design tensile stress perpendicular (at 90 degrees) to

grain alignment. Sc0d Design compressive stress parallel to grain alignment. Sc90d Design compressive stress perpendicular to grain

alignment. Smzd Design bending stress about zz axis. Smyd Design bending stress about yy axis. Svd Design shear stress. Stor_d Design torsional stress. Ft0d Design tensile strength - parallel to the grain

alignment. Ft90d Design tensile strength - perpendicular to the grain

alignment. Fc0d Design compressive strength - parallel to the grain

alignment. Fc90d Design compressive strength - perpendicular to the

grain alignment. Fmzd Design bending strength - about zz-axis. Fmyd Design bending strength - about yy-axis. Fvd Design shear strength about yy axis. RATIO Permissible ratio of stresses as provided by the user.

The default value is 1.

Page 308: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-50

Symbols Description

λz ,λrel,z Slenderness ratios corresponding to bending about zz

axis. λy,λrel,y Slenderness ratios corresponding to bending about yy

axis. E0,05 Fifth percentile value of modulus of elasticity parallel

to grain. G0,05 Fifth percentile value of shear modulus parallel to

grain. Iz Second moment of area about the strong z-axis. Iy Second moment of area about the weak y-axis. Itor Torsional moment of inertia. fmk Characteristic bending strength. b, h Width and depth of beam. Equations for Characteristic Values of Timber Species as per Annex-A of EN 338:2003 The following equations were used to determine the characteristic values: Basic Inputs: For a particular Timber Strength Class (TSC), the

following characteristic strength values are required to compute the other related characteristic values.

1. Bending Strength – fm,k 2. Mean Modulus of Elasticity in bending – E0, mean 3. Density - ρk

Page 309: International Design Codes

Section 5C 5-51

Wood Type

Sl. No.

Property Symbol Softwood (C)

Hardwood (D)

1. Tensile Strength parallel to grain

ft,0,k 0.6 * fm,k

2. Tensile Strength perpendicular to grain

ft,90,k Minimum of {0.6 and (0.0015*ρk)}

3. Compressive Strength parallel to grain

fc,0,k 5 * (fm,k ) 0.45

4. Compressive Strength perpendicular to grain

fc,90,k 0.007*ρk 0.0015*ρk

5. Shear Strength fv,k Minimum of {3.8 and (0.2*fm,k 0.8)}

6. Modulus of Elasticity parallel to grain

E0,05 0.67* E0,mean 0.84* E0,mean

7. Mean Modulus of Elasticity perpendicular to grain

E90,mean E0,mean /30 E0,mean /15

8. Mean Shear Modulus Gmean E0,mean /16

9. Shear Modulus G0,05 E0,05 /16

The values of the characteristic strengths computed using the above equations, may differ with the tabulated values in Table-1 of EN 338:2003. However, in all such cases, the values obtained from the provided equations are treated as actual and is used by the program, as the values of Table-1 are based on these equations. Finding the Design values of Characteristic Strength As per clause 2.4.1, Design values of a strength property shall be calculated as: ( )mkd XmodKX γ×=

Page 310: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-52

Where Xd is design value of strength property, Xk characteristic value of strength property and γm is partial factor for material properties. The member resistance in timber structure, is calculated in STAAD according to the procedures outlined in EC5. This depends on several factors such as cross sectional properties, different load and material factors, timber strength class, load duration class, service class and so on. The methodology adopted in STAAD for calculating the member resistance is explained here. Check for Tension stresses If the direction of applied axial tension is parallel to the direction of timber grain alignment, the following formula should be checked: ( ) RATIO F S t0dt0d ≤ …….(cf : Equation 6.1 of EC-5-2004)

If the direction of applied axial tension is perpendicular to the direction of timber grain alignment, the following formula should be checked: ( ) RATIO F S t90dt90d ≤

Check for Compression stresses If the direction of applied axial compression is parallel to the direction of timber grain alignment, the following formula should be checked: ( ) RATIO F S c0dc0d ≤ …….(cf:Equation 6.2 of EC-5-2004)

If the direction of applied axial compression is perpendicular to the direction of timber grain alignment, the following formula should be checked: ( ) RATIO Kc90F S c90dc90d ≤× (cf:Equation 6.3 of EC-5-2004)

Page 311: International Design Codes

Section 5C 5-53

Check for Bending stresses If members are under bending stresses, the following conditions should be satisfied.Please note that in STAAD z-z axis is the strong axis:

RATIOFS

KmFS

myd

myd

mzd

mzd ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛.(cf:Equation 6.11 of EC-5-2004)

RATIOFS

FS

Kmmyd

myd

mzd

mzd ≤⎟⎟⎠

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

⎛× .(cf:Equation 6.12 of EC-5-2004)

Check for Shear stresses

Horizontal stresses are calculated and checked against allowable values:

RATIOFS

vd

vd ≤⎟⎟⎠

⎞⎜⎜⎝

⎛ …….( cf:Equation 6.13 of EC-5-2004)

Check for Torsional stresses Members subjected to torsional stress should satisfy the following equation:

RATIOFKshape

S

tor_d

tor_d ≤⎟⎟⎠

⎞⎜⎜⎝

× .( cf:Equation 6.14 of EC-5-2004)

Page 312: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-54

Check for combined Bending and Axial tension Members subjected to combined action of bending and axial tension stress should satisfy the following conditions. Please note that in STAAD z-z axis is the strong axis:

RATIO F S

KmFS

FS

myd

myd

mzd

mzd

t0d

t0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

…. (cf:Equation 6.17 of EC-5-2004)

RATIO F S

FS

Km F S

myd

myd

mzd

mzd

t0d

t0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛+⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

…. ( cf:Equation 6.18 of EC-5-2004) Check for combined Bending and axial Compression If members are subjected to bending and axial compression stress, following equations should be satisfied. Please note that in STAAD z-z axis is the strong axis:

RATIO F S

KmFS

F S

myd

myd

mzd

mzd

2

c0d

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

…. ( cf:Equation 6.19 of EC-5-2004)

RATIO F S

FS

KmF

S

myd

myd

mzd

mzd

2

c0d

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

…. ( cf:Equation 6.20 of EC-5-2004)

Page 313: International Design Codes

Section 5C 5-55

Stability check (A) Column Stability check

The relative slenderness ratios should be calculated as follows. Please note that in STAAD z-z axis is the strong axis:

0,05

c0kzz,rel E

πλ

=λ …….( Equation 6.21 of EC-5-2004)

0,05

c0kyy,rel E

π

λ=λ …….( Equation 6.22 of EC-5-2004)

If both λrel,z and λrel,y are less than or equal to 0.3 the following conditions should be satisfied:

RATIO F S

KmFS

F S

myd

myd

mzd

mzd

2

c0d

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

RATIO F S

FS

Km F S

myd

myd

mzd

mzd

2

c0d

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

In other cases, the following conditions should be satisfied. Please note that in STAAD z-z axis is the strong axis:

RATIO F S

KmFS

FKcz S

myd

myd

mzd

mzd

c0d

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

⎛×

… ( cf:Equation 6.23 of EC-5-2004)

Page 314: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-56

RATIO F S

FS

Km FKcy

S

myd

myd

mzd

mzd

c0d

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛+⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛×

... ( cf:Equation 6.24 of EC-5-2004) Where the symbols Kcz and Kcy are defined as follows. Please note that in STAAD z-z axis is the strong axis:

( ) ( )2z,rel2KzKz

1Kczλ−+

= ...( Equation 6.25 of EC-5-2004)

( ) ( )2y,rel2KzKy

1Kcyλ−+

= …( Equation 6.26 of EC-5-2004)

( ) ( )( )2

z,relz,relc 3.015.0Kz λ+−λ×β+×= ( Equation 6.27 of EC-5-2004)

( ) ( )( )2

y,rely,relc 3.015.0Ky λ+−λ×β+×= .( Equation 6.28 of EC-5-2004)

The value of βc incorporated in the software is the one for solid timber ,i.e. 0.2.

(B) Beam Stability check

If members are subjected to only a moment about the strong axis z, the stresses should satisfy the following equation:

RATIOFKcrit

S

mzd

mzd ≤×

….( cf:Equation 6.33 of EC-5-2004)

Page 315: International Design Codes

Section 5C

5-57 Where a combination of moment about the strong z-axis and compressive force exists, the stresses should satisfy the following equation:

RATIOFKcz

SFKcrit

S

c0d

c0d2

mzd

mzd ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×

+⎟⎟⎠

⎞⎜⎜⎝

⎛×

…… ( cf:Equation 6.35 of EC-5-2004) Where,

( )⎪⎪⎪

⎪⎪⎪

λ<λ

≤λ<λ×−≤λ

=

mrel,2mrel,

mrel,m,rel

mrel,

4.1for11.475.0for75.056.1

0.75 for 1Kcrit

….. ( Equation 6.34 of EC-5-2004)

crit,m

mkm,rel S

f=λ ……..( Equation 6.30 of EC

-5-2004)

For hardwood:

…. (Equation 6.31 of EC-5-2004) For softwood:

05,0ef

2

crit,m Elh

b78.0S ×××

= ….( Equation 6.32 of EC-5-2004)

zef

tor05,0y05,0crit,m Wl

IGIES

×

××××π=

Page 316: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-58

5C.3 Design Parameters

Design parameters communicate specific design decisions to the program. They are set to default values to begin with and may be altered to suite the particular structure.

Depending on the model being designed, the user may have to change some or all of the parameter default values. Some parameters are unit dependent and when altered, the new setting must be compatible with the active “unit” specification.

Parameter Name

Default Value

Description

SCL 3 Service Class (Ref. Cl.2.3.1.3) ♦ 1 = Class 1, Moisture content <= 12% ♦ 2 = Class 2, Moisture content <= 20% ♦ 3 = Class 3, Moisture content > 20%

LDC 1 Load Duration Class (Ref. Cl.2.3.1.2), required to get the K-MOD value from Table – 3.1. ♦ 1 - Permanent action ♦ 2 - Long term action ♦ 3 - Medium term action ♦ 4 - Short term action ♦ 5 - Instantaneous action

Page 317: International Design Codes

Section 5C 5-59

Parameter Name

Default Value

Description

TSC 6 (C24) Timber Strength Class (Ref. Reference EN338 – 2003) Softwood: 1 = C14, 2 = C16, 3 = C18, 4 = C20, 5 = C22, 6 = C24, 7 = C27, 8 = C30, 9 = C35, 10 = C40, 11 = C45, 12 = C50. Hardwood: 13 = D30, 14 = D35, 15 = D40, 16 = D50, 17 = D60, 18 = D70. This TSC definition will calculate the corresponding characteristic strength values using the equations as given in BS-EN-338, Annex - A.

ALPHA 0.0 Angle of inclination of load to the grain alignment. (Ref. Cl.6.1.1, Cl.6.1.2, Cl.6.1.3, Cl.6.1.4) 0.0 = Load parallel to grain, 90.0 = Load Perpendicular to grain

KC90 1.0 Factor taking into account the load configuration, possibility of splitting and degree of compressive deformation. (Ref. Cl.6.1.5-(2)) ♦ Range: 1.0 ≤ KC90 ≤ 4.0 ♦ Other than the default value, user may specify any value within the range, depending on load-position, load-dispersion, contact length at support locations etc.

Page 318: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-60

Parameter Name

Default Value

Description

MTYP 0 Member Type: Beam/Column. (Ref. Cl.6.3.2, Cl.6.3.3) ♦ 0 – Not defined by the user – checks both clauses (Default). ♦ 1 – Beam Member ♦ 2 – Column Member This information is required to find which stability check will be performed as per the Cl 6.3 according to the Member Type.

KLEF 1.0 (Member Length)

Effective Length Factor to check Lateral Torsional Buckling. (Ref. Table 6.1) Span of the beam depending on the support conditions and load configurations. The user will put the appropriate value from the Table 6.1. Required only for MTYP has a value of 1 (Beam).

KLY 1.0 (Member Length)

Effective Length Factor for Local-y-axis. (Ref. Cl.6.3.2), for the computation of the relative slenderness ratios.

KLZ 1.0 (Member Length)

Effective Length Factor for Local-z-axis. (Ref. Cl.6.3.2), for the computation of the relative slenderness ratios.

TRACK 0 Degree/Level of Details of design output results. Available options: 0 / 1 / 2

RATIO 1.0 Permissible ratio of actual to allowable value.

Page 319: International Design Codes

Section 5C 5-61

Parameter Name

Default Value

Description

SERV No Default Value

Defines the load case numbers – those are to be considered for serviceability (deflection) check. ♦ The list of this parameter must contain only the valid load-case numbers. ♦ Deflection checks will be performed only on those load-case results. ♦ If this parameter is not provided, then in-spite of the presence of the parameter DFF – the deflection check will NOT be performed.

DFF No Default Value

“Deflection Length” / Max. Allowable Net Final Local Deflection. In this case, deflection check will be performed, if both the parameters SERV and DFF are present with specific values. For appropriate range of values, please refer Cl.7.2 (Table 7.2)

DJ1 Start node number for a physical member under consideration for Deflection Check.

DJ2 End node number for a physical member under consideration for Deflection Check.

5C.4 Verification Problems

In the next few pages are included 2 verification examples for reference purposes.

Page 320: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-62

Verification Problem No. 1

A Timber Column of length 1.0 meter, having c/s dimension of 73 mm X 198 mm, is subjected to an axial compressive force of 50.0 kN. Design of the member - ULTIMATE LIMIT STATE Material properties:

Timber class: C24 Service classes: Class 2, moisture content <= 20% Load duration classes: Medium-term

Cross section properties:

Length of the member is 1 m. Rectangular cross section, b = 73 mm, h = 198 mm, Effective cross sectional area A = 14454 mm², Radius of gyration of cross section about y-axis ry = 21 mm, Radius of gyration of cross section about z-axis rz = 57 mm, Section modulus of cross section about z-axis: Wz = 4.770x105 mm³ Section modulus of cross section about y-axis: Wy = 1.759x105 mm³

Characteristic material properties for timber:

Modification factor Kmod = 0.80 …from table 3.1 Material factors γm = 1.30 … from table 2.3 fc0k = 21.00 N/mm², Fc0d = (Kmod.fc0k)/γm = (0.80x21.00)/1.30 = 12.92 N/mm²[Cl 2.4.1(1)P]

Page 321: International Design Codes

Section 5C 5-63

Cross section loads:

Fx = 50.000 kN Compression parallel to the grain:

Sc0d = (1000xFx)/A = (1000x50.000)/14454 = 3.46N/mm² < 12.92N/mm² (Fc0d) The ratio of actual compressive stress to allowable compressive strength: = 3.46 / 12.92 = 0.268 < 1.0 [Cl. 6.1.4.(1)P]

Check for Slenderness:

Slenderness ratios: λz = (1000/57) = 17.54 and λy = (1000/21) = 47.62

E0,mean = 1.1031 kN/m2

As timber grade is C24, i.e, Soft Wood, E0,05 = 0.67 * E0,mean … [Annex A,EN 338:2003]

05,0

k0cyy,rel E

f×⎟⎟⎠

⎞⎜⎜⎝

⎛π

λ=λ = 0.809

05,0

k0czz,rel E

f×⎟⎠⎞

⎜⎝⎛πλ

=λ = 0.298

Since, λrel,y is greater than 0.3, following conditions should be satisfied:

RATIO F SKm

FS

FK S

mzd

mzd

myd

myd

c0dyc,

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟

⎟⎠

⎞⎜⎜⎝

⎛+⎟

⎟⎠

⎞⎜⎜⎝

× [Cl.

6.3.2.(3)]

Page 322: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-64

RATIO F S

KmFS

FKcz S

myd

myd

mzd

mzd

c0d

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

⎛×

[Cl.

6.3.2.(3)]

( ) ( )( )2yrel,yrel,y 3.1.5K λλ +−+×= = 0.878

( ) ( )( )2zrel,zrel,z 3.1.5K λ+−λ+×= = 0.541

2y,rel

2yy

y,cKK1K

λ−+= = 0.82

2z,rel

2zz

z,cKK1K

λ−+= = 1.0

For Rectangular cross section Km = 0.70. The member is subjected to Compression only, so actual bending stress is zero.

⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟

⎟⎠

⎞⎜⎜⎝

⎛+⎟

⎟⎠

⎞⎜⎜⎝

× F SKm

FS

FK S

mzd

mzd

myd

myd

c0dyc,

c0d = 0.326 + 0.0 + 0.0

= 0.326

⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

⎛× F

SKm

FS

FKcz S

myd

myd

mzd

mzd

c0d

c0d = 0.268 + 0.0 + 0.0

= 0.268 Hence the critical ratio is 0.326 < 1.0 and the section is safe.

Page 323: International Design Codes

Section 5C 5-65

The Input File: STAAD SPACE START JOB INFORMATION ENGINEER DATE END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 1.0 0 0; MEMBER INCIDENCES 1 1 2; DEFINE MATERIAL START ISOTROPIC WOOD E 1.10316e+007 POISSON 0.15 DENSITY 0.00231749 ALPHA 5.5e-006 END DEFINE MATERIAL CONSTANTS MATERIAL WOOD MEMB 1 MEMBER PROPERTY 1 PRIS YD 0.198 ZD 0.073 SUPPORTS 1 FIXED LOAD 1 LOADTYPE NONE TITLE LOAD CASE 1 JOINT LOAD 2 FX -50 PERFORM ANALYSIS PARAMETER CODE TIMBER EC5 ALPHA 0 ALL LDC 3 ALL SCL 2 ALL TSC 6 ALL TRACK 2 ALL CHECK CODE ALL FINISH

Page 324: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C

5-66

The member checking part of the output file:

Page 325: International Design Codes

Section 5C 5-67

Verification Problem No. 2:

A Timber Column of length 1.0 meter, having c/s dimension of 73 mm X 198 mm, is subjected to an axial compressive force of 5.0 kN and moments of 2.0 kN.m and 1.0 kN.m about its major and minor axes respectively. Design of the member - ULTIMATE LIMIT STATE Material properties:

Timber Strength Class: C24 Service classes: Class 2, moisture content <=20% Load duration: Medium-term

Cross section properties:

Length of the member is 1 m. Rectangular cross section, b = 73 mm, h = 198 mm, Effective cross sectional area A = 14454 mm², Radius of gyration of cross section about y-axis ry = 21 mm, Radius of gyration of cross section about z-axis rz = 57 mm, Section modulus of cross section about z-axis: Wz = 4.770x105 mm³ Section modulus of cross section about y-axis: Wy = 1.759x105 mm³

Characteristic material properties for timber:

Modification factor, Kmod = 0.80 Material factor γm = 1.30 fc0k = 21.00 N/mm², E0,05 = 7370 N/mm2, Fc0d = Kmod.fc0k/γm = (0.80x21.00)/1.30 = 12.92N/mm² fmyk = 24.00 N/mm², Fmyd = Kmod.fmyk/γm = (0.80x24.00)/1.30 = 14.77N/mm² fmzk = 24.00 N/mm², Fmzd = Kmod.fmzk/γm = (0.80x24.00)/1.30 = 14.77N/mm²

Page 326: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-68

Cross section loads:

Fx = 5.000 kN, Mz = 2.000 kN.m, My = 1.000 kN.m Check for Slenderness:

Slenderness ratios: λz = (1000/57) = 17.54 and λy = (1000/21) = 47.62

05,0

k0cyy,rel E

f×⎟⎟⎠

⎞⎜⎜⎝

⎛π

λ=λ = 0.809

05,0

k0czz,rel E

f×⎟⎠⎞

⎜⎝⎛πλ

=λ = 0.298

Since, λrel,y is greater than 0.3, following conditions should be satisfied:

RATIO F SKm

FS

FK S

mzd

mzd

myd

myd

c0dyc,

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟

⎟⎠

⎞⎜⎜⎝

⎛+⎟

⎟⎠

⎞⎜⎜⎝

× [Cl. 6.3.2.(3)]

RATIO F S

KmFS

FKcz S

myd

myd

mzd

mzd

c0d

c0d ≤⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

⎛×

[Cl. 6.3.2.(3)]

( ) ( )( )2yrel,yrel,y 3.1.5K λ+−λ+×= = 0.878

( ) ( )( )2zrel,zrel,z 3.1.5K λ+−λ+×= = 0.541

2y,rel

2yy

y,cKK1K

λ−+= = 0.82

2z,rel

2zz

z,cKK1K

λ−+= = 1.0

Page 327: International Design Codes

Section 5C 5-69

For Rectangular cross section Km = 0.70 Sc0d = (1000Fx/A) = (1000x5.000)/14454 = 0.35 N/mm² Smzd = (106xMz)/Wz = (106x2.000)/(4.770x105) = 4.19 N/mm² Smyd = (106xMy)/Wy = (106x1.000)/(1.759x105) = 5.69 N/mm²

⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟

⎟⎠

⎞⎜⎜⎝

⎛+⎟

⎟⎠

⎞⎜⎜⎝

× F SKm

FS

FK S

mzd

mzd

myd

myd

c0dyc,

c0d

= 0.033 + 0.385 + 0.198 = 0.616

⎟⎟⎠

⎞⎜⎜⎝

⎛×+⎟⎟

⎞⎜⎜⎝

⎛+⎟⎟

⎞⎜⎜⎝

⎛× F

SKm

FS

FKcz S

myd

myd

mzd

mzd

c0d

c0d

= 0.027 + 0.283 + 0.269 = 0.579 Hence the critical ratio is 0.616 < 1.0 and the section is safe.

Page 328: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-70

The Input File: STAAD SPACE START JOB INFORMATION ENGINEER DATE 08-Jun-05 END JOB INFORMATION INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 0 1 0; MEMBER INCIDENCES 1 1 2; DEFINE MATERIAL START ISOTROPIC WOOD E 1.10316e+007 POISSON 0.15 DENSITY 0.00231749 ALPHA 5.5e-006 END DEFINE MATERIAL CONSTANTS MATERIAL WOOD MEMB 1 MEMBER PROPERTY 1 PRIS YD 0.198 ZD 0.073 SUPPORTS 1 FIXED LOAD 1 LOADTYPE NONE TITLE LOAD CASE 1 JOINT LOAD 2 FY -5.0 MX 1.0 MZ 2.0 PERFORM ANALYSIS PARAMETER CODE TIMBER EC5 ALPHA 0 ALL LDC 3 ALL SCL 2 ALL TSC 6 ALL TRACK 2 ALL CHECK CODE ALL FINISH

Page 329: International Design Codes

Section 5C

5-71 The member checking part of the output file:

Page 330: International Design Codes

Timber Design Per EC 5: Part 1-1. Section 5C 5-72

Page 331: International Design Codes

Section 6 French Codes

Page 332: International Design Codes

A’lkjdfl’akjsfd

Page 333: International Design Codes

6-1

Concrete Design Per B.A.E.L.

6A.1 Design Operations

STAAD has the capabilities for performing design of concrete beams, columns and slabs according to B.A.E.L. - 1983. Given the width and depth (or diameter for circular columns) of a section, STAAD will calculate the required reinforcing to resist the various input loads.

6A.2 Design Parameters

The program contains a number of parameters which are needed to perform design per B.A.E.L. These parameters not only act as a method to input required data for code calculations but give the engineer control over the actual design process. Default values, of commonly used numbers in conventional design practice, have been used for simplicity. Table 5A.1 contains a complete list of available parameters and their default values.

6A.3 Slenderness Effects and Analysis Consideration

STAAD provides the user two methods of accounting for the slenderness effect in the analysis and design of concrete members. The first method is a procedure which takes into account second order effects. Here, STAAD accounts for the secondary moments, due to axial loads and deflections, when the PDELTA ANALYSIS command is used. STAAD, after solving for the joint displacements of the structure, calculates the additional moments induced in the structure. Therefore, by using PDELTA

Section 6A

Page 334: International Design Codes

Concrete Design Per B.A.E.L.

Section 6A 6-2 ANALYSIS, member forces are calculated which will require no user modification before beginning member design. The second method by which STAAD allows the user to account for the slenderness effect is through user supplied moment magnification factors. Here the user approximates the additional moment by supplying a factor by which moments will be multiplied before beginning member design.

6A.4 Member Dimensions

Concrete members that are to be designed by STAAD must have certain section properties input under the MEMBER PROPERTIES command. The following example demonstrates the required input:

UNIT MM MEMBER PROPERTIES 1 3 to 7 9 PRISM YD 450 ZD 300. 11 13 PR YD 300.

In the above input, the first set of members are rectangular (450 mm depth and 300 mm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with a 300 mm diameter. Note that area (AX) is not provided for these members. If shear areas (AY & AZ) are to be considered in analysis, the user may provide them along with YD and ZD. Also note that moments of inertia may be provided, but if not provided, the program will calculate values from YD and ZD.

Page 335: International Design Codes

Section 6A 6-3

6A.5 Beam Design

Beam design includes both flexure and shear. For both types of beam action, all active beam loadings are scanned to create moment and shear envelopes, and locate critical sections. The total number of sections considered is twelve, unless that number is redefined with the NSECTION parameter. From the critical moment values, the required positive and negative bar pattern is developed, with cut-off lengths calculated to include required development length. Shear design includes critical shear values plus torsional moments. From these values, stirrup sizes are calculated with proper spacing. The stirrups are assumed to be U-shaped for beams with no torsion, and closed hoops for beams subject to torsion.

Table 6A.1 French Concrete Design Parameters

Parameter Default Description Name Value

FYMAIN * 300 N/mm2 Yield Stress for main reinforcing steel.

FYSEC * 300 N/mm2 Yield Stress for secondary reinforcing steel.

FC * 30 N/mm2 Concrete Yield Stress.

CLEAR * 20 mm Clearance of reinforcing bar. Value is automatically set to 20 mm for C35 and higher.

MINMAIN 8 mm Minimum main reinforcement bar size. (8mm - 60mm).

MINSEC 8 mm Minimum secondary reinforcement bar size. (8mm - 60mm).

MAXMAIN 50 mm Maximum main reinforcement bar size. (8mm - 60mm).

SFACE *0.0 Face of support location at start of beam. (Only considers shear - use MEMBER OFFSET for bending).

Page 336: International Design Codes

Concrete Design Per B.A.E.L.

Section 6A 6-4

Table 6A.1 French Concrete Design Parameters

Parameter Default Description Name Value

EFACE *0.0 Face of Support Location at end of beam. (Note: Both SFACE and EFACE are input as positive numbers.).

TRACK 0.0 Critical Moment will not be printed out with beam design report. A value of 1.0 will mean a print out.

MMAG 1.0 A factor by which the design moments will be magnified.

NSECTION 10 Number of equally-spaced sections to be considered in finding critical moments for beam design.

WIDTH ZD Width of the concrete member. This value defaults to ZD as provided under MEMBER PROPERTIES.

DEPTH YD Depth of concrete member. This value defaults to YD as provided under MEMBER PROPERTIES.

* These values must be provided in the units the user is currently using for input.

Example of Input Data for Beam Design UNIT NEWTON MMS START CONCRETE DESIGN CODE FRENCH FYMAIN 415 ALL FYSEC 415 ALL FC 35 ALL CLEAR 25 MEM 2 TO 6 MAXMAIN 40 MEMB 2 TO 6 SFACE 100 MEMB 7 TO 9 EFACE 100 MEMB 7 TO 9 TRACK 1.0 MEMB 2 TO 6 TRACK 2.0 MEMB 7 TO 9 DESIGN BEAM 2 TO 9 END CONCRETE DESIGN

Page 337: International Design Codes

Section 6A 6-5

6A.6 Column Design

Columns are designed for axial force and biaxial moments at the ends. All active loadings are tested to calculate reinforcement. The loading which produces maximum reinforcement is called the critical load. Column design is done for square, rectangular and circular sections. For rectangular and square sections, the reinforcement is always assumed to be equally distributed on each side. That means the total number of bars will always be a multiple of four (4). This may cause slightly conservative results in some cases.

Example of Input Data for Column Design UNIT NEWTON MMS START CONCRETE DESIGN CODE FRENCH FYMAIN 415 ALL FC 35 ALL CLEAR 25 MEMB 2 TO 6 MMAG 1.5 MEMB 4 5 MAXMAIN 40 MEMB 2 TO 6 DESIGN COLUMN 2 TO 6 END CONCRETE DESIGN

6A.7 Slab/Wall Design

Slab and walls are designed per BAEL 1983 specifications. To design a slab or wall, it must be modeled using finite elements. The command specifications are in accordance with Chapter II, section 6.40. Elements are designed for the moments Mx and My. These moments are obtained from the element force output (see Chapter 2 of the Technical Reference Manual). The reinforcement required

Page 338: International Design Codes

Concrete Design Per B.A.E.L.

Section 6A 6-6 to resist Mx moment is denoted as longitudinal reinforcement and the reinforcement required to resist My moment is denoted as transverse reinforcement. The parameters FYMAIN, FC, and CLEAR listed in Table 5A.1 are relevant to slab design. Other parameters mentioned in Table 5A.1 are not applicable to slab design.

LONG.

TRANS.

X

Y

Z

M

MM

M x

y

x

y

Example of Input Data for Slab/Wall Design UNIT NEWTON MMS START CONCRETE DESIGN CODE FRENCH FYMAIN 415 ALL FC 25 ALL CLEAR 40 ALL DESIGN ELEMENT 15 TO 20 END CONCRETE DESIGN

Page 339: International Design Codes

6-7

Steel Design Per the French Code

6B.1 General Comments

STAAD implementation of French Steel Design is based on Centre Technique Industriel de la Construction Metallique publication entitled "Design Rules for Structural Steelwork." The design philosophy embodied in this specification is based on the concept of limit state design. Structures are designed and proportioned according to the limit states of which they would become unfit for their intended use. Two major categories of limit-states are recognized: ultimate and serviceability. The primary considerations in ultimate limit state design are strength and stability; that in serviceability is deflection. Appropriate load and resistance factors are used so that uniform reliability is achieved for all steel structures under various loading conditions and at the same time the chances of limits being surpassed are acceptably remote. In the STAAD implementation, members are proportioned to resist the design loads without exceeding the limit states of strength, stability and serviceability. Accordingly, the most economic section is selected on the basis of the least weight criteria, as augmented by the designer in specification of allowable member depths, desired section type, or other related parameters. The code checking portion of the program verifies that code requirements for each selected section are met and also identifies the governing criteria.

Section 6B

Page 340: International Design Codes

Steel Design per the French Code

Section 6B 6-8 The following sections describe the salient features of STAAD implementation of "Design Rules for Structural Steelwork." A detailed description of the design process, along with its underlying concepts and assumptions, is available in the specification document.

6B.2 Basis of Methodology

The "Design Rules for Structural Steelwork (Revision 80)" permits the usage of elastic analysis. Thus, in STAAD, linear elastic analysis method is used to obtain the forces and moments in the members. However, strength and stability considerations are based on the principles of plastic behaviour. Axial compression buckling and lateral torsional buckling are taken into consideration for calculation of axial compression resistance and flexural resistance of members. Slenderness calculations are made and overall geometric stability is checked for all members.

6B.3 Member Capacities

The member strengths are calculated in STAAD according to the procedures outlined in section 4 of this specification. Note that the program automatically considers co-existence of axial force, shear and bending in calculating section capacities. For axial tension capacity, procedures of section 4.2 are followed. For axial compression capacity, formulas of section 5.3 are used. Moment capacities about both axes are calculated using the procedures of sections 4.5 and 4.6. Lateral torsional buckling is considered in calculating ultimate twisting moment per section 5.22 of the specification. The parameter UNL (see Table 6B.1) must be used to specify the unsupported length of the compression flange for a laterally unsupported member. Note that this length is also referred to as twisting length.

Page 341: International Design Codes

Section 6B 6-9

6B.4 Combined Axial Force and Bending

The procedures of sections 4.55 and 5.32 are implemented for interaction of axial forces and bending. Appropriate interaction equations are used and the governing criteria is determined.

6B.5 Design Parameters

The design parameters outlined in Table 6B.1 may be used to control the design procedure. These parameters communicate design decisions from the engineer to the program, thus allowing the engineer to control the design process to suit an application's specific needs. The default parameter values have been selected as frequently used numbers for conventional design. Depending on the particular design requirements, some or all of these parameter values may be changed to exactly model the physical structure.

6B.6 Code Checking and Member Selection

Both code checking and member selection options are available in STAAD implementation of CM 66 (Revn. 80). For general information on these options, refer to Chapter II, sections 3.4 and 3.5. For information on specification of these commands, refer to Chapter II, and section 6.46.

6B.7 Tabulated Results of Steel Design

Results of code checking and member selection are presented in the output file in a tabular format. Please note the following: COND CRITIQUE refers to the section of the CM 66 (Revn. 80) specification which governed the design.

Page 342: International Design Codes

Steel Design per the French Code

Section 6B 6-10 If the TRACK parameter is set to 1.0, calculated member capacities will be printed. The following is a detailed description of printed items: PC = Member Compression Capacity TR = Member Tension Capacity MUZ = Member Moment Capacity (about z-axis) MUY = Member Moment Capacity (about y-axis) VPZ = Member Shear Capacity (z-axis) VPY = Member Shear Capacity (y-axis)

Table 6B.1 French Steel Design Parameters

Parameter Default Description Name Value

KY 1.0 K value for axial compression buckling about local Y-axis. Usually, this is the minor axis.

KZ 1.0 K value for axial compression buckling about local Z-axis. Usually, this is the major axis.

LY Member Length Length to calculate slenderness ratio about Y-axis for axial compression.

LZ Member Length Length to calculate slenderness ratio about Z-axis for axial compression.

FYLD 250.0 MPa Yield strength of steel.

NSF 1.0 Net section factor for tension members.

UNL Member Length Unsupported length of compression flange for calculating moment resistance.

UNF 1.0 Same as above provided as a fraction of member length.

TRACK 0.0 0.0 = Suppress printing of all design strengths. 1.0 = Print all design strengths.

DMAX 100.0 cm. Maximum allowable depth (used in member selection).

DMIN 0.0 cm. Minimum allowable depth (used in member selection).

RATIO 1.0 Permissible ratio of actual load effect and design strength.

Page 343: International Design Codes

Section 6B 6-11

Table 6B.1 French Steel Design Parameters

Parameter Default Description Name Value

BEAM 0.0 0.0 = design only for end moments and those at locations specified by SECTION command. 1.0 = calculate moments at tenth points along the beam, and use maximum Mz for design.

STAAD contains a broad set of facilities for designing structural members as individual components of an analyzed structure. The member design facilities provide the user with the ability to carry out a number of different design operations. These facilities may be used selectively in accordance with the requirements of the design problem. The operations to perform a design are: • Specify the members and the load cases to be considered in the

design. • Specify whether to perform code checking or member

selection. • Specify design parameter values, if different from the default

values. These operations may be repeated by the user any number of times depending upon the design requirements. Currently STAAD supports steel design of wide flange, S, M, HP shapes, angle, double angle, channel, double channel, beams with cover plate, composite beams and code checking of prismatic properties.

Page 344: International Design Codes

Steel Design per the French Code

Section 6B 6-12

Sample Input data for Steel Design UNIT METER PARAMETER CODE FRENCH NSF 0.85 ALL UNL 10.0 MEMBER 7 KY 1.2 MEMBER 3 4 RATIO 0.9 ALL TRACK 1.0 ALL CHECK CODE ALL

6B.8 Built-in French Steel Section Library

The following information is provided for use when the built-in steel tables are to be referenced for member property specification. These properties are stored in a database file. If called for, the properties are also used for member design. Since the shear areas are built into these tables, shear deformation is always considered for these members. An example of the member property specification in an input file is provided at the end of this section. A complete listing of the sections available in the built-in steel section library may be obtained by using the tools of the graphical user interface. Following are the descriptions of different types of sections.

Page 345: International Design Codes

Section 6B 6-13

IPE Shapes These shapes are designated in the following way.

10 15 TA ST IPE140 20 TO 30 TA ST IPEA120 33 36 TO 46 BY 2 TA ST IPER180

HE shapes HE shapes are specified as follows.

3 5 TA ST HEA120A 7 10 TA ST HEM140 13 14 TA ST HEB100

IPN Shapes The designation for the IPN shapes is similar to that for the IPE shapes.

25 TO 35 TA ST IPN200 23 56 TA ST IPN380

T Shapes Tee sections are not input by their actual designations, but instead by referring to the I beam shapes from which they are cut. For example,

1 5 TA T IPE140 2 8 TA T HEM120

Page 346: International Design Codes

Steel Design per the French Code

Section 6B 6-14 U Channels Shown below is the syntax for assigning 4 different names of channel sections.

1 TO 5 TA ST UAP100 6 TO 10 TA ST UPN220 11 TO 15 TA ST UPN240A 16 TO 20 TA ST UAP250A

Double U Channels Back to back double channels, with or without a spacing between them, are available. The letter D in front of the section name will specify a double channel.

11 TA D UAP150 17 TA D UAP250A SP 0.5

In the above set of commands, member 11 is a back to back double channel UAP150 with no spacing in between. Member 17 is a double channel UAP250A with a spacing of 0.5 length units between the channels. Angles Two types of specification may be used to describe an angle. The standard angle section is specified as follows:

16 20 TA ST L30X30X2.7

The above section signifies an angle with legs of length 30mm and a leg thickness of 2.7mm. This specification may be used when the local Z axis corresponds to the z-z axis specified in Chapter 2. If the local Y axis corresponds to the z-z axis, type specification "RA" (reverse angle) should be used instead of ST.

17 21 TA RA L25X25X4

Page 347: International Design Codes

Section 6B 6-15

22 24 TA RA L100X100X6.5

Note that if the leg thickness is a round number such as 4.0, only the number 4 appears in the section name, the decimal part is not part of the section name. Double Angles Short leg back to back or long leg back to back double angles can be specified by means of input of the words SD or LD, respectively, in front of the angle size. In case of an equal angle, either SD or LD will serve the purpose.

33 35 TA SD L30X20X4 SP 0.6 37 39 TA LD L80X40X6 43 TO 47 TA LD L80X80X6.5 SP 0.75

Tubes (Rectangular or Square Hollow Sections) Section names of tubes, just like angles, consist of the depth, width and wall thickness as shown below.

64 78 TA ST TUB50252.7 66 73 TA ST TUB2001008.0

Members 64 and 78 are tubes with a depth of 50mm, width of 25mm and a wall thickness of 2.7mm. Members 66 and 73 are tubes with a depth of 200mm, width of 100mm and a wall thickness of 8.0mm. Unlike angles, the ".0" in the thickness is part of the section name. Tubes can also be input by their dimensions instead of by their table designations. For example,

6 TA ST TUBE DT 8.0 WT 6.0 TH 0.5

Page 348: International Design Codes

Steel Design per the French Code

Section 6B 6-16 is a tube that has a depth of 8 length units, width of 6 length units, and a wall thickness of 0.5 length units. Only code checking, no member selection, will be performed for TUBE sections specified in this way. Pipes (Circular Hollow Sections) To designate circular hollow sections, use PIP followed by numerical value of the diameter and thickness of the section in mm omitting the decimal portion of the value provided for the diameter. The following example illustrates the designation.

8 TO 28 TA ST PIP422.6 3 64 78 TA ST PIP21912.5

Members 8 to 28 are pipes 42.4mm in dia, having a wall thickness of 2.6mm. Members 3, 64 and 78 are pipes 219.1mm in dia, having a wall thickness of 12.5mm. Circular hollow sections may also be provided by specifying the outside and inside diameters of the section. For example,

1 TO 9 TA ST PIPE OD 25.0 ID 20.0

specifies a pipe with outside dia. of 25 length units and inside dia. of 20 length units. Only code checking, no member selection will be performed if this type of specification is used.

SAMPLE FILE CONTAINING FRENCH SHAPES STAAD SPACE UNIT METER KN JOINT COORD 1 0 0 0 15 140 0 0 MEMB INCI 1 1 2 14

Page 349: International Design Codes

Section 6B 6-17

UNIT CM MEMBER PROPERTIES FRENCH * IPE SHAPES 1 TA ST IPEA120 * IPN SHAPES 2 TA ST IPN380 *HE SHAPES 3 TA ST HEA200 * T SHAPES 4 TA T HEM120 * U CHANNELS 5 TA ST UAP100 * DOUBLE U CHANNELS 6 TA D UAP150 SP 0.5 * ANGLES 7 TA ST L30X30X2.7 * REVERSE ANGLES 8 TA RA L25X25X4 * DOUBLE ANGLES - SHORT LEGS BACK * TO BACK 9 TA SD L30X20X4 SP 0.25 * DOUBLE ANGLES - LONG LEGS BACK * TO BACK 10 TA LD L80X40X6 SP 0.75 * TUBES (RECTANGULAR OR SQUARE * HOLLOW SECTIONS) 11 TA ST TUB50252.7 * TUBES (RECTANGULAR OR SQUARE * HOLLOW SECTIONS) 12 TA ST TUBE DT 8.0 WT 6.0 TH 0.5 * PIPES (CIRCULAR HOLLOW SECTIONS) 13 TA ST PIP422.6 * PIPES (CIRCULAR HOLLOW SECTIONS) 14 TA ST PIPE OD 25.0 ID 20.0 PRINT MEMB PROP FINI

Page 350: International Design Codes

Steel Design per the French Code

Section 6B 6-18

Page 351: International Design Codes

Section 7 German Codes

Page 352: International Design Codes

Aslkdfj;alskjdf’

Page 353: International Design Codes

7-1

Concrete Design Per DIN 1045

Section 7A

7A.1 Design Operations

STAAD has the capabilities of performing concrete design based on the DIN 1045 - November 1989. Slab design is also available but this follows the requirements of Baumann, Munich, which is the basis for Eurocode 2. Design for a member involves calculation of the amount of reinforcement required for the member. Calculations are based on the user specified properties and the member forces obtained from the analysis. In addition, the details regarding placement of the reinforcement on the cross section are also reported in the output.

7A.2 Section Types for Concrete Design

The following types of cross sections for concrete members can be designed. For Beams - Prismatic (Rectangular & Square) For Columns - Prismatic (Rectangular, Square and Circular)

7A.3 Member Dimensions

Concrete members which will be designed by the program must have certain section properties input under the MEMBER PROPERTY command. The following example shows the required input:

Page 354: International Design Codes

Concrete Design Per DIN 1045

Section 7A 7-2

UNIT MM MEMBER PROPERTY 1 3 TO 7 9 PRISM YD 450. ZD 250. 11 13 PR YD 350.

In the above input, the first set of members are rectangular (450 mm depth and 250mm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with 350mm diameter. It is absolutely imperative that the user not provide the cross section area (AX) as an input.

7A.4 Slenderness Effects and Analysis Considerations

Slenderness effects are extremely important in designing compression members. There are two options by which the slenderness effect can be accommodated. The first method is equivalent to the procedure presented in DIN 1045 17.4.3/17.4.4 which is used as the basis for commonly used design charts considering e/d and sk/d for conditions where the slenderness moment exceeds 70. This method has been adopted in the column design in STAAD per the DIN code. The second option is to compute the secondary moments through an analysis. Secondary moments are caused by the interaction of the axial loads and the relative end displacements of a member. The axial loads and joint displacements are first determined from an elastic stiffness analysis and the secondary moments are then evaluated. To perform this type of analysis, use the command PDELTA ANALYSIS instead of PERFORM ANALYSIS in the input file. The user must note that to take advantage of this analysis, all the combinations of loading must be provided as primary load cases and not as load combinations. This is due to the fact that load combinations are just algebraic combinations of forces and moments, whereas a primary load case is revised during

Page 355: International Design Codes

Section 7A 7-3

the P-delta analysis based on the deflections. Also, note that the proper factored loads (like 1.5 for dead load etc.) should be provided by the user. STAAD does not factor the loads automatically. The column is designed for the total moment which is the sum of the primary and secondary forces. The secondary moments can be compared to those calculated using the charts of DIN 1045.

7A.5 Beam Design

Beams are designed for flexure, shear and torsion. For all these forces, all active beam loadings are prescanned to identify the critical load cases at different sections of the beams. The total number of sections considered is 13 (e.g. 0., .1, .2, .25, .3, .4, .5, .6, .7, .75, .8, .9 and 1). All of these sections are scanned to determine the design force envelopes. Design for Flexure

Maximum sagging (creating tensile stress at the bottom face of the beam) and hogging (creating tensile stress at the top face) moments are calculated for all active load cases at each of the above mentioned sections. Each of these sections is designed to resist these critical sagging and hogging moments. Currently, design of singly reinforced sections only is permitted. If the section dimensions are inadequate as a singly reinforced section, such a message will be printed in the output. Flexural design of beams is performed in two passes. In the first pass, effective depths of the sections are determined with the assumption of single layer of assumed reinforcement and reinforcement requirements are calculated. After the preliminary design, reinforcing bars are chosen from the internal database in single or multiple layers. The entire flexural design is performed again in a second pass taking into account the changed effective depths of sections calculated on the basis of reinforcement provided after the preliminary design. Final provision of flexural reinforcements are made then. Efforts have been made to meet the guideline for the curtailment of reinforcements as per the DIN code. Although exact curtailment lengths are not mentioned explicitly in the design output (finally which will be more or less guided by the

Page 356: International Design Codes

Concrete Design Per DIN 1045

Section 7A 7-4 detailer taking into account of other practical considerations), the user has the choice of printing reinforcements provided by STAAD at 13 equally spaced sections from which the final detailed drawing can be prepared. Design for Shear and Torsion

Shear design in STAAD conforms to the specifications of section 17.5 of DIN 1045. Shear reinforcement is calculated to resist both shear forces and torsional moments. Shear and torsional design is performed at the start and end sections of the member at a distance "d" away from the node of the member where "d" is the effective depth calculated from flexural design. The maximum shear forces from amongst the active load cases and the associated torsional moments are used in the design. The capacity of the concrete in shear and torsion is determined at the location of design and the balance, if any, is carried by reinforcement. It is assumed that no bent-up bars are available from the flexural reinforcement to carry and "balance" shear. Two-legged stirrups are provided to take care of the balance shear forces acting on these sections. Stirrups are assumed to be U-shaped for beams with no torsion, and closed hoops for beams subject to torsion.

Example of Input Data for Beam Design UNIT NEWTON MMS START CONCRETE DESIGN CODE GERMAN FYMAIN 415 ALL FYSEC 415 ALL FC 35 ALL CLEAR 25 MEM 2 TO 6 MAXMAIN 40 MEMB 2 TO 6 TRACK 1.0 MEMB 2 TO 9 DESIGN BEAM 2 TO 9 END CONCRETE DESIGN

Page 357: International Design Codes

Section 7A 7-5

7A.6 Column Design

Columns are designed for axial forces and biaxial moments at the ends. All active load cases are tested to calculate reinforcement. The loading which yields maximum reinforcement is called the critical load. The requirements of DIN 1045-figure 13, for calculating the equilibrium equations for rectangular and circular sections from first principles, is implemented in the design. The user has control of the effective length (sk) in each direction by using the ELZ and ELY parameters as described on Table 6A.1. This means that the slenderness will be evaluated along with e/d to meet the requirements of DIN 1045 section 17.4.3 and 17.4.4. Column design is done for square, rectangular and circular sections. Square and rectangular columns are designed with reinforcement distributed on all four sides equally. That means the total number of bars will always be a multiple of four (4). This may cause slightly conservative results in some cases. The TRACK parameter may be used to obtain the design details in various levels of descriptivity.

Example of Input Data for Column Design UNIT NEWTON MMS START CONCRETE DESIGN CODE GERMAN FYMAIN 415 ALL FC 35 ALL CLEAR 25 MEMB 2 TO 6 MAXMAIN 40 MEMB 2 TO 6 DESIGN COLUMN 2 TO 6 END CONCRETE DESIGN

Page 358: International Design Codes

Concrete Design Per DIN 1045

Section 7A 7-6

7A.7 Slab Design

To design a slab, it must first be modeled using finite elements and analysed. The command specifications are in accordance with Chapter 2 and Chapter 6 of the Technical Reference Manual. Slabs are designed to specifications as described by BAUMANN of MUNICH which is the basis for Eurocode 2. Elements are designed for the moments Mx and My. These moments are obtained from the element force output (see Chapter 2 of the Technical Reference Manual). The reinforcement required to resist the Mx moment is denoted as longitudinal reinforcement and the reinforcement required to resist the My moment is denoted as transverse reinforcement. The following parameters are those applicable to slab design: 1. FYMAIN Yield stress for all reinforcing steel 2. FC Concrete grade 3. CLEAR Distance from the outer surface of the element to

the edge of the bar. This is considered the same on both top and bottom surfaces of the element.

4. SRA Parameter which denotes the angle of direction of the required transverse reinforcement relative to the direction of the longitudinal reinforcement for the calculation of BAUMANN design forces.

The other parameters shown in Table 7A.1 are not applicable to slab design. BAUMANN equations

If the default value of zero is used, the design will be based on Mx and My forces which are obtained from the STAAD analysis. The SRA parameter (Set Reinforcement Angle) can be manipulated to introduce resolved BAUMANN forces into the design replacing the pure Mx and My moments. These new design moments allow the Mxy moment to be considered when designing the section, resolved as an axial force. Orthogonal or skew reinforcement may

Page 359: International Design Codes

Section 7A 7-7

be considered. If SRA is set to -500, an orthogonal layout will be assumed. If however a skew is to be considered, an angle is given in degrees measured from the local element X axis anticlockwise (positive). The resulting Mx* and My* moments are calculated and shown in the design format. The design of the slab considers a fixed bar size of 10mm in the longitudinal direction and 8mm in the transverse. The longitudinal bar is the layer closest to the slab exterior face.

7A.8 Design Parameters

The program contains a number of parameters which are needed to perform the design. Default parameter values have been selected such that they are frequently used numbers for conventional design requirements. These values may be changed to suit the particular design being performed. Table 7A.1 of this manual contains a complete list of the available parameters and their default values. It is necessary to declare length and force units as Millimeter and Newton before performing the concrete design.

Table 7A.1 German Concrete Design Parameters

Parameter Name

Default Value Description

FYMAIN 420 N/mm2 Yield Stress for main reinforcement (For slabs it is 500 N/mm2 for both directions)

FYSEC 420N/mm2 Yield Stress for secondary reinforcement. Applicable to shear and torsion reinforcement in beams

FC 25N/mm2 Concrete Yield Stress/ cube strength

MINMAIN 16mm Minimum main reinforcement bar size [Acceptable bar sizes: 6 8 10 12 14 16 20 25 32 40 50]

MINSEC 8mm Minimum secondary reinforcement bar size. Applicable to shear and torsion reinforcement in beams.

Page 360: International Design Codes

Concrete Design Per DIN 1045

Section 7A 7-8

Table 7A.1 German Concrete Design Parameters

Parameter Name

Default Value Description

CLEAR 25mm Clear cover for reinforcement measured from concrete surface to closest bar perimeter.

MAXMAIN 50 mm Maximum required reinforcement bar size. Acceptable bars are per MINMAIN above.

SFACE 0.0 Face of support location at start of beam, measured from the start joint. (Only applicable for shear - use MEMBER OFFSET for bending)

EFACE 0.0 Face of support location at end of beam, measured from the end joint. (NOTE: Both SFACE & EFACE must be positive numbers.)

TRACK 0.0 0.0 = Critical Moment will not be printed with beam design report.

1.0 = For beam gives min/max steel % and spacing. For columns gives a detailed table of output with additional moments calculated.

2.0 = For beams gives area of steel required at intermediate sections. (see NSECT)

MMAG 1.0 Factor by which design moments are magnified for column design

NSECTION 10 Number of equally-spaced sections to be considered in finding critical moment for beam design. The upper limit is 20

WIDTH ZD Width of concrete member. The default value is as provided as ZD in MEMBER PROPERTIES.

DEPTH YD Depth of concrete member. The default value is as provided as YD in MEMBER PROPERTIES.

ELY 1.0 Member length factor about local Y direction for column design

ELZ 1.0 Member length factor about local Z direction for column design

Page 361: International Design Codes

Section 7A 7-9

Table 7A.1 German Concrete Design Parameters

Parameter Name

Default Value Description

SRA 0.0 0.0 = Orthogonal reinforcement layout without considering torsional moment Mxy -slabs only

-500 = Orthogonal reinforcement layout considering Mxy

A = Skew angle considered in BAUMANN equations. A is the angle in degrees.

Page 362: International Design Codes

Concrete Design Per DIN 1045

Section 7A 7-10

Page 363: International Design Codes

7-11

Steel Design Per the DIN Code

Section 7B

7B.1 General

This section presents some general statements regarding the implementation of the DIN code of practice for structural steel design (DIN 18800 and DIN 4114) in STAAD. The design philosophy and procedural logistics are based on the principles of elastic analysis and allowable stress design. Facilities are available for member selection as well as code checking. Two major failure modes are recognized: failure by overstressing and failure by stability considerations. The following sections describe the salient features of the design approach. Members are proportioned to resist the design loads without exceedance of the allowable stresses or capacities and the most economical section is selected on the basis of the least weight criteria. The code checking part of the program also checks the slenderness requirements and the stability criteria. Users are recommended to adopt the following steps in performing the steel design:

1) Specify the geometry and loads and perform the analysis. 2) Specify the design parameter values if different from the

default values. 3) Specify whether to perform code checking or member

selection.

Page 364: International Design Codes

Steel Design per the DIN Code

Section 7B 7-12

7B.2 Analysis Methodology

Elastic analysis method is used to obtain the forces and moments for design. Analysis is done for the primary and combination loading conditions provided by the user. The user is allowed complete flexibility in providing loading specifications and in using appropriate load factors to create necessary loading situations. Depending upon the analysis requirements, regular stiffness analysis or P-Delta analysis may be specified. Dynamic analysis may also be performed and the results combined with static analysis results.

7B.3 Member Property Specifications

For specification of member properties of standard German steel sections, the steel section library available in STAAD may be used. The next section describes the syntax of commands used to assign properties from the built-in steel table. Members properties may also be specified using the User Table facility. For more information on these facilities, refer to the STAAD Program User's manual.

7B.4 Built-in German Steel Section Library

The following information is provided for use when the built-in steel tables are to be referenced for member property specification. These properties are stored in a database file. If called for, these properties are also used for member design. Since the shear areas are built into these tables, shear deformation is always considered for these members during the analysis. An example of member property specification in an input file is provided at the end of this section.

Page 365: International Design Codes

Section 7B 7-13

A complete listing of the sections available in the built-in steel section library may be obtained using the tools of the graphical user interface. Following are the descriptions of different types of sections. IPE Shapes These shapes are designated in the following way:

20 TO 30 TA ST IPEA120 33 36 TO 46 BY 2 TA ST IPER140

HE Shapes The designation for HE shapes is similar to that for IPE shapes.

25 TO 35 TA ST HEB300 23 56 TA ST HEA160

I Shapes I shapes are identified by the depth of the section. The following example illustrates the designation.

14 15 TA ST I200 (indicates an I-section with 200mm depth)

T Shapes Tee sections are not input by their actual designations, but instead by referring to the I beam shapes from which they are cut. For example,

1 5 TA T HEA220 2 8 TA T IPE120

Page 366: International Design Codes

Steel Design per the DIN Code

Section 7B 7-14 U Channels The example below provides the command for identifying two channel sections. The former (U70X40) has a depth of 70mm and a flange width of 40mm. The latter (U260) has a depth of 260mm.

11 TA D U70X40 27 TA D U260

Double Channels Back to back double channels, with or without spacing between them, are available. The letter “D” in front of the section name will specify a double channel, e.g. D U180. The spacing between the double channels is provided following the expression “SP”.

11 TA D U180 27 TA D U280 SP 0.5 (Indicates 2 channels back to back spaced at 0.5 length units)

Angles Two types of specifications may be used to describe an angle. The standard angle section is specified as follows:

16 20 TA ST L20X20X2.5

The above section signifies an angle with legs of length 20mm and a leg thickness of 2.5mm. The above specification may be used when the local z-axis corresponds to the Z-Z axis specified in Chapter 2. If the local y-axis corresponds to the Z-Z axis, type specification "RA" (reverse angle) may be used.

17 21 TA RA L40X20X5

Page 367: International Design Codes

Section 7B 7-15

Double Angles Short leg back to back or long leg back to back double angles can be specified by using the word SD or LD, respectively, in front of the angle size. In case of an equal angle, either SD or LD will serve the purpose. Spacing between the angles is provided by using the word SP and the spacing value following the section name.

14 TO 20 TA SD L40X20X4 SP 0.5 21 TO 27 TA LD L40X20X4 SP 0.5

Pipes (Circular Hollow Sections) To designate circular hollow sections, use PIP followed by numerical value of the diameter and thickness of the section in mm omitting the decimal section of the value provided for diameter. The following example will illustrate the designation.

8 TO 28 TA ST PIP602.9 (60.3mm dia, 2.9mm wall thickness) 3 64 67 TA ST PIP40612.5 (406.4mm dia, 12.5mm wall thickness)

Circular hollow sections may also be provided by specifying the outside and inside diameters of the section. For example,

1 TO 9 TA ST PIPE OD 25.0 ID 20.0

specifies a pipe with outside dia. of 25 and inside dia. of 20 in current length units. Only code checking and no member selection will be performed if this type of specification is used.

Page 368: International Design Codes

Steel Design per the DIN Code

Section 7B 7-16 Tubes (Rectangular or Square Hollow Sections) Tube names are input by their dimensions. For example,

15 TO 25 TA ST TUB100603.6

is the specification for a tube having sides of 100mmX60mm and the wall thickness of 3.6mm. Tubes, like pipes can also be input by their dimensions (Height, Width and Thickness) instead of by their table designations.

6 TA ST TUBE DT 8.0 WT 6.0 TH 0.5

is a tube that has a height of 8, a width of 6, and a wall thickness of 0.5 in current length units. Only code checking and no member selection will be performed for TUBE sections specified this way.

SAMPLE INPUT FILE CONTAINING GERMAN SHAPES STAAD SPACE UNIT METER KN JOINT COORDINATES 1 0 0 0 15 140 0 0 MEMBER INCIDENCES 1 1 2 14 UNIT CM MEMBER PROPERTIES GERMAN * IPE SHAPES 1 TA ST IPEA120 * HE SHAPES 2 TA ST HEB300 * I SHAPES 3 TA ST I200 * T SHAPES 4 TA T HEA220

Page 369: International Design Codes

Section 7B 7-17

* U CHANNELS 5 TA ST U70X40 * DOUBLE U CHANNELS 6 TA D U260 * ANGLES 7 TA ST L20X20X2.5 * REVERSE ANGLES 8 TA RA L40X20X5 * DOUBLE ANGLES - LONG LEGS BACK TO BACK 9 TA LD L40X20X4 SP 0.5 * DOUBLE ANGLES - SHORT LEGS BACK TO BACK 10 TA SD L40X20X4 SP 0.5 * PIPES 11 TA ST PIP602.9 * PIPES 12 TA ST PIPE OD 25.0 ID 20.0 * TUBES 13 TA ST TUB100603.6 * TUBES 14 TA ST TUBE DT 8.0 WT 6.0 WT 0.5 * PRINT MEMBER PROPERTIES FINISH

7B.5 Member Capacities

The allowable stresses used in the implementation are based on DIN 18800 (Part 1) - Section 7. The procedures of DIN 4114 are used for stability analysis. The basic measure of member capacities are the allowable stresses on the member under various conditions of applied loading such as allowable tensile stress, allowable compressive stress etc. These depend on several factors such as cross sectional properties, slenderness factors, unsupported width to thickness ratios and so on. Explained here is the procedure adopted in STAAD for calculating such capacities.

Page 370: International Design Codes

Steel Design per the DIN Code

Section 7B 7-18 Allowable stress for Axial Tension

In members with axial tension, the tensile load must not exceed the tension capacity of the member. The tension capacity of the member is calculated on the basis of the member area. STAAD calculates the tension capacity of a given member based on a user supplied net section factor (NSF-a default value of 1.0 is present but may be altered by changing the input value, see Table 6B.1) and proceeds with member selection or code checking. Allowable stress for Axial Compression

The allowable stress for members in compression is determined according to the procedure of DIN 4114 (Part 1) - Section 7. Compressive resistance is a function of the slenderness of the cross-section (Kl/r ratio) and the user may control the slenderness value by modifying parameters such as KY, LY, KZ and LZ. Allowable stress for Bending and Shear

The permissible bending compressive and tensile stresses are dependent on such factors as length of outstanding legs, thickness of flanges, unsupported length of the compression flange (UNL, defaults to member length) etc. Shear capacities are a function of web depth, web thickness etc. Users may use a value of 1.0 or 2.0 for the TRACK parameter to obtain a listing of the bending and shear capacities.

7B.6 Combined Loading

For members experiencing combined loading (axial force, bending and shear), applicable interaction formulas are checked at different locations of the member for all modeled loading situations. Members subjected to axial force and bending are checked using the criteria of DIN 18800 (Part 1) - Section 6.1.6. In addition, for members with compression and bending, the criteria of DIN 4114 (Part 1) - Section 10 is used. Similarly, for members with axial tension and bending, the criteria of DIN 4114 (Part 1) - Section 15 is used.

Page 371: International Design Codes

Section 7B 7-19

7B.7 Design Parameters

The user is allowed complete control over the design process through the use of parameters mentioned in Table 7B.1 of this chapter. These parameters communicate design decisions from the engineer to the program. The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements of the situation, some or all of these parameter values may have to be changed to exactly model the physical structure.

Table 7B.1 German Steel Design Parameters

Parameter Name

Default Value Description

KY 1.0 K value in local y-axis. Usually, this is the minor axis.

KZ 1.0 K value in local z-axis. Usually, this is the major axis.

LY Member Length Length in local y-axis to calculate slenderness ratio.

LZ Member Length Length in local z-axis to calculate slenderness ratio.

PY 240 N/sq.mm Strength of steel.

NSF 1.0 Net section factor for tension members.

UNL Member Length Unrestrained member length in lateral torsional buckling checks.

UNF 1.0 Same as above provided as a factor of actual member length.

BEAM 0.0 Number of sections to be checked per member: 0.0 = Design only for end sections. 1.0 = Check at location of maximum MZ

along member.

2.0 = Check ends plus location of beam 1.0 check.

Page 372: International Design Codes

Steel Design per the DIN Code

Section 7B 7-20

Table 7B.1 German Steel Design Parameters

Parameter Name

Default Value Description

3.0 = Check at every 1/13th of the member length and report the maximum.

TRACK 0.0 Level of detail in output file: 0.0 = Output summary of results 1.0 = Output summary of results plus

member capacities

2.0 = Output detailed results

RATIO 1.0 Permissible ratio of actual to allowable stresses

SGR 0.0 Grade of steel:

0.0 = St 37-2

1.0 = St 52-3

2.0 = StE 355

SBLT 0 Specify section as either rolled or built-up:

0 = Rolled

1 = Built-up

Cb 0 Beam coefficient n, defined in Table 9: If Cb = 0, program will use n = 2.5 for rolled sections and 2.0 for welded sections.

Cmm 1.0 Moment factor, Zeta, defined in Table 10:

1.0 = fixed ended member with constant moment, Zeta = 1.0

2.0 = pin ended member with UDL, Zeta = 1.12

3.0 = pin ended member with central point load, Zeta = 1.35

4.0 = fixed ended member, Zeta calculated from end moments.

DMAX 1.0 m Maximum allowable depth during member selection

DMIN 0.0 m Minimum required depth during member selection

Page 373: International Design Codes

Section 7B 7-21

Table 7B.1 German Steel Design Parameters

Parameter Name

Default Value Description

SAME 0.0 Control of sections to try during a SELECT process:

0.0 = Try every section of the same type as the original.

1.0 = Try only those with a similar name.

7B.8 Code Checking

The purpose of code checking is to check whether the provided section properties of the members are adequate to carry the forces transmitted to it by the loads on the structure. The adequacy is checked per the DIN requirements. Code checking is done using forces and moments at specified sections of the members. If the BEAM parameter for a member is set to 1, moments are calculated at every twelfth point along the beam, and the maximum moment about the major axis is used. When no sections are specified and the BEAM parameter is set to zero (default), design will be based on member start and end forces. The code checking output labels the members as PASSed or FAILed. In addition, the critical condition, governing load case, location (distance from start joint) and magnitudes of the governing forces and moments are also printed.

Page 374: International Design Codes

Steel Design per the DIN Code

Section 7B 7-22

7B.9 Member Selection

The member selection process basically involves determination of the least weight member that PASSes the code checking procedure based on the forces and moments of the most recent analysis. The section selected will be of the same type as that specified initially. For example, a member specified initially as a channel will have a channel selected for it. Selection of members whose properties are originally provided from a user table will be limited to sections in the user table. Member selection cannot be performed on TUBES, PIPES or members listed as PRISMATIC.

Sample Input data for Steel Design UNIT METER PARAMETER CODE GERMAN NSF 0.85 ALL UNL 10.0 MEMBER 7 KY 1.2 MEMBER 3 4 RATIO 0.9 ALL TRACK 1.0 ALL CHECK CODE ALL

Page 375: International Design Codes

Section 8 Indian Codes

Page 376: International Design Codes

Ad;flaksd;lfka

Page 377: International Design Codes

8-1

Concrete Design Per IS456

Section 8A

8A.1 Design Operations

STAAD has the capabilities of performing concrete design. It will calculate the reinforcement needed for any concrete section. All the concrete design calculations are based on limit state method of IS: 456 (2000).

8A.2 Section Types for Concrete Design

The following types of cross sections for concrete members can be designed. For Beams Prismatic (Rectangular & Square), T-Beams and

L-shapes For Columns Prismatic (Rectangular, Square and Circular)

8A.3 Member Dimensions

Concrete members which will be designed by the program must have certain section properties input under the MEMBER PROPERTY command. The following example shows the required input:

Page 378: International Design Codes

Concrete Design Per IS456

Section 8A 8-2

UNIT MM MEMBER PROPERTY 1 3 TO 7 9 PRISM YD 450. ZD 250. 11 13 PR YD 350. 14 TO 16 PRIS YD 400. ZD 750. YB 300. ZB 200.

will be done accordingly. In the above input, the first set of members are rectangular (450 mm depth and 250mm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with 350 mm diameter. The third set numbers in the above example represents a T-shape with 750 mm flange width, 200 width, 400 mm overall depth and 100 mm flange depth (See section 6.20.2). The program will determine whether the section is rectangular, flanged or circular and the beam or column design

8A.4 Design Parameters

The program contains a number of parameters which are needed to perform design as per IS:456(2000). Default parameter values have been selected such that they are frequently used numbers for conventional design requirements. These values may be changed to suit the particular design being performed. Table 8A.1 of this manual contains a complete list of the available parameters and their default values. It is necessary to declare length and force units as Millimeter and Newton before performing the concrete design.

8A.5 Slenderness Effects and Analysis Consideration

Slenderness effects are extremely important in designing compression members. The IS:456 code specifies two options by which the slenderness effect can be accommodated (Clause 39.7).

Page 379: International Design Codes

Section 8A 8-3

One option is to perform an exact analysis which will take into account the influence of axial loads and variable moment of inertia on member stiffness and fixed end moments, the effect of deflections on moment and forces and the effect of the duration of loads. Another option is to approximately magnify design moments. STAAD has been written to allow the use of the first options. To perform this type of analysis, use the command PDELTA ANALYSIS instead of PERFORM ANALYSIS. The PDELTA ANALYSIS will accommodate all requirements of the second- order analysis described by IS:456, except for the effects of the duration of the loads. It is felt that this effect may be safely ignored because experts believe that the effects of the duration of loads is negligible in a normal structural configuration. Although ignoring load duration effects is somewhat of an approximation, it must be realized that the approximate evaluation of slenderness effects is also an approximate method. In this method, additional moments are calculated based on empirical formula and assumptions on sidesway (Clause 39.7.1 and 39.7.1.1,IS: 456 - 2000). Considering all these information, a PDELTA ANALYSIS, as performed by STAAD may be used for the design of concrete members. However the user must note, to take advantage of this analysis, all the combinations of loading must be provided as primary load cases and not as load combinations. This is due to the fact that load combinations are just algebraic combinations of forces and moments, whereas a primary load case is revised during the P-delta analysis based on the deflections. Also note that the proper factored loads (like 1.5 for dead load etc.) should be provided by user. STAAD does not factor the loads automatically.

8A.6 Beam Design

Beams are designed for flexure, shear and torsion. If required the effect the axial force may be taken into consideration. For all

Page 380: International Design Codes

Concrete Design Per IS456

Section 8A 8-4 these forces, all active beam loadings are prescanned to identify the critical load cases at different sections of the beams. The total number of sections considered is 13 ( e.g. 0.,.1,.2,.25,.3,.4,.5,.6,.7,. 75,.8,.9 and 1). All of these sections are scanned to determine the design force envelopes. Design for Flexure

Maximum sagging (creating tensile stress at the bottom face of the beam) and hogging (creating tensile stress at the top face) moments are calculated for all active load cases at each of the above mentioned sections. Each of these sections are designed to resist both of these critical sagging and hogging moments. Where ever the rectangular section is inadequate as singly reinforced section, doubly reinforced section is tried. However, presently the flanged section are designed only as singly reinforced section under sagging moment. It may also be noted all flanged sections are automatically designed as rectangular section under hogging moment as the flange of the beam is ineffective under hogging moment. Flexural design of beams are performed in two passes. In the first pass, effective depths of the sections are determined with the assumption of single layer of assumed reinforcement and reinforcement requirements are calculated. After the preliminary design, reinforcing bars are chosen from the internal database in single or multiple layers. The entire flexure design is performed again in a second pass taking into account of the changed effective depths of sections calculated on the basis of reinforcement provide after the preliminary design. Final provision of flexural reinforcements are made then. Efforts have been made to meet the guideline for the curtailment of reinforcements as per IS:456-2000 (Clause 26.2.3). Although exact curtailment lengths are not mentioned explicitly in the design output (finally which will be more or less guided by the detailer taking into account of other practical consideration), user has the choice of printing reinforcements provided by STAAD at 11 equally spaced sections from which the final detail drawing can be prepared.

Page 381: International Design Codes

Section 8A 8-5

Design for Shear

Shear reinforcement is calculated to resist both shear forces and torsional moments. Shear design are performed at 11 equally spaced sections (0.to 1.) for the maximum shear forces amongst the active load cases and the associated torsional moments. Shear capacity calculation at different sections without the shear reinforcement is based on the actual tensile reinforcement provided by STAAD program. Two-legged stirrups are provided to take care of the balance shear forces acting on these sections. As per Clause 40.5 of IS:456-2000 shear strength of sections (< 2d where d is the effective depth) close to support has been enhanced, subjected to a maximum value of τcmax. Beam Design Output The default design output of the beam contains flexural and shear reinforcement provided at 5 equally spaced (0,.25,.5,.75 and 1.) sections along the length of the beam. User has option to get a more detail output. All beam design outputs are given in IS units. An example of rectangular beam design output with the default output option (TRACK 0.0) is presented below:

Page 382: International Design Codes

Concrete Design Per IS456

Section 8A 8-6 ============================================================================ B E A M N O. 12 D E S I G N R E S U L T S M20 Fe415 (Main) Fe415 (Sec.) LENGTH: 4000.0 mm SIZE: 250.0 mm X 350.0 mm COVER: 30.0 mm DESIGN LOAD SUMMARY (KN MET) ---------------------------------------------------------------------------- SECTION |FLEXTURE (Maxm. Sagging/Hogging moments)| SHEAR (in mm) | P MZ MX Load Case | VY MX Load Case ---------------------------------------------------------------------------- 0.0 | 0.00 0.00 0.00 4 | 29.64 1.23 4 | 0.00 -25.68 1.23 4 | 400.0 | 0.00 0.00 0.00 4 | 27.97 1.23 4 | 0.00 -16.05 1.23 4 | 800.0 | 0.00 0.00 0.00 4 | 25.12 1.23 4 | 0.00 -7.17 1.23 4 | 1200.0 | 0.00 0.97 0.49 5 | 21.11 1.23 4 | 0.00 -0.14 1.32 6 | 1600.0 | 0.00 6.77 1.23 4 | 15.93 1.23 4 | 0.00 0.00 0.00 4 | 2000.0 | 0.00 11.06 1.23 4 | 9.59 1.23 4 | 0.00 0.00 0.00 4 | 2400.0 | 0.00 13.04 1.23 4 | 2.08 1.23 4 | 0.00 0.00 0.00 4 | 2800.0 | 0.00 12.45 1.23 4 | -5.43 1.23 4 | 0.00 0.00 0.00 4 | 3200.0 | 0.00 9.55 1.23 4 | -11.77 1.23 4 | 0.00 0.00 0.00 4 | 3600.0 | 0.00 4.73 1.23 4 | -16.95 1.23 4 | 0.00 0.00 0.00 4 | 4000.0 | 0.00 0.00 0.00 4 | -25.48 1.23 4 | 0.00 -17.36 1.23 4 | ---------------------------------------------------------------------------- SUMMARY OF REINF. AREA (Sq.mm) ---------------------------------------------------------------------------- SECTION 0.0 mm 1000.0 mm 2000.0 mm 3000.0 mm 4000.0 mm ---------------------------------------------------------------------------- TOP 259.04 161.29 0.00 0.00 176.31 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) BOTTOM 0.00 160.78 160.78 160.78 0.00 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) ---------------------------------------------------------------------------- SUMMARY OF PROVIDED REINF. AREA ---------------------------------------------------------------------------- SECTION 0.0 mm 1000.0 mm 2000.0 mm 3000.0 mm 4000.0 mm ---------------------------------------------------------------------------- TOP 4-10Ø 3-10Ø 2-10Ø 2-10Ø 3-10Ø REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) BOTTOM 2-12Ø 2-12Ø 2-12Ø 2-12Ø 2-12Ø REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) SHEAR 2 legged 8Ø 2 legged 8Ø 2 legged 8Ø 2 legged 8Ø 2 legged 8Ø REINF. @ 100 mm c/c @ 100 mm c/c @ 100 mm c/c @ 100 mm c/c @ 100 mm c/c ----------------------------------------------------------------------------

============================================================================

Page 383: International Design Codes

Section 8A 8-7

8A.7 Column Design

Columns are designed for axial forces and biaxial moments at the ends. All active load case are tested to calculate reinforcement. The loading which yield maximum reinforcement is called the critical load. Column design is done for square, rectangular and circular sections. By default, square and rectangular columns and designed with reinforcement distributed on each side equally for the sections under biaxial moments and with reinforcement distributed equally in two faces for sections under uniaxial moment. User may change the default arrangement of the reinforcement with the help of the parameter RFACE (see Table 8A.1). Depending upon the member lengths, section dimensions and effective length coefficients specified by the user STAAD automatically determine the criterion (short or long) of the column design. All major criteria for selecting longitudinal and transverse reinforcement as stipulated by IS:456 have been taken care of in the column design of STAAD. Default clear spacing between main reinforcing bars is taken to be 25 mm while arrangement of longitudinal bars. Column Design Output Default column design output (TRACK 0.0) contains the reinforcement provided by STAAD and the capacity of the section. With the option TRACK 1.0, the output contains intermediate results such as the design forces, effective length coefficients, additional moments etc. A special output TRACK 9.0 is introduced to obtain the details of section capacity calculations. All design output is given in SI units. An example of a long column design (Ref. Example 9 of SP:16, Design Aids For Reinforced Concrete to IS:456-1978) output (with option TRACK 1.0) is given below.

Page 384: International Design Codes

Concrete Design Per IS456

Section 8A 8-8 ============================================================================ C O L U M N N O. 1 D E S I G N R E S U L T S M20 Fe415 (Main) Fe415 (Sec.) LENGTH: 3000.0 mm CROSS SECTION: 250.0 mm dia. COVER: 40.0 mm ** GUIDING LOAD CASE: 5 BRACED LONG COLUMN DESIGN FORCES (KNS-MET) ----------------------- DESIGN AXIAL FORCE (Pu) : 62.0 About Z About Y INITIAL MOMENTS : 2.21 32.29 MOMENTS DUE TO MINIMUM ECC. : 1.24 1.24 SLENDERNESS RATIOS : 12.00 12.00 MOMENTS DUE TO SLENDERNESS EFFECT : 1.12 1.12 MOMENT REDUCTION FACTORS : 1.00 1.00 ADDITION MOMENTS (Maz and May) : 1.12 1.12 TOTAL DESIGN MOMENTS : 3.32 33.40 REQD. STEEL AREA : 1822.71 Sq.mm. MAIN REINFORCEMENT : Provide 17 - 12 dia. (3.92%, 1922.65 Sq.mm.) (Equally distributed) TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 190 mm c/c SECTION CAPACITY (KNS-MET) -------------------------- Puz : 992.70 Muz1 : 36.87 Muy1 : 36.87 INTERACTION RATIO: 1.00 (as per Cl. 38.6, IS456)

============================================================================

Page 385: International Design Codes

Section 8A 8-9

Table 8A.1 Indian Concrete Design IS456 Parameters

Parameter Name Default Value Description

FYMAIN 415 N/mm2 Yield Stress for main reinforcing steel.

FYSEC 415 N/mm2 Yield Stress for secondary reinforcing steel.

FC 30 N/mm2 Concrete Yield Stress.

CLEAR 25 mm 40 mm

For beam members. For column members

MINMAIN 10 mm Minimum main reinforcement bar size.

MAXMAIN 60 mm Maximum main reinforcement bar size.

MINSEC 8 mm Minimum secondary reinforcement bar size.

MAXSEC 12 mm Maximum secondary reinforcement bar size.

BRACING

0.0

BEAM DESIGN

A value of 1.0 means the effect of axial force will be taken into account for beam design.

COLUMN DESIGN

A value of 1.0 means the column is unbraced about major axis.

A value of 2.0 means the column is unbraced about minor axis.

A value of 3.0 means the column is unbraced about both axis.

RATIO 4.0 Maximum percentage of longitudinal reinforcement in columns.

RFACE 4.0 A value of 4.0 means longitudinal reinforcement in column is arranged equally along 4 faces.

A value of 2.0 invokes 2 faced distribution about major axis.

A value of 3.0 invokes 2 faced distribution about minor axis.

WIDTH ZD Width to be used for design. This value defaults to ZD as provided under MEMBER PROPERTIES.

DEPTH YD Total depth to be used for design. This value defaults to YD as provided under MEMBER PROPERTIES.

Page 386: International Design Codes

Concrete Design Per IS456

Section 8A 8-10

Table 8A.1 Indian Concrete Design IS456 Parameters

Parameter Name Default Value Description

TRACK 0.0 BEAM DESIGN: For TRACK = 0.0, output consists of reinforcement details at START, MIDDLE and END. For TRACK = 1.0, critical moments are printed in addition to TRACK 0.0 output. For TRACK = 2.0, required steel for intermediate sections defined by NSECTION are printed in addition to TRACK 1.0 output.

COLUMN DESIGN: With TRACK = 0.0, reinforcement details are printed. With TRACK = 1.0, column interaction analysis results are printed in addition to TRACK 0.0 output. With TRACK = 2.0, a schematic interaction diagram and intermediate interaction values are printed in addition to TRACK 1.0 output.

With TRACK = 9.0, the details of section capacity calculations are printed.

REINF 0.0 Tied column. A value of 1.0 will mean spiral reinforcement.

ELZ 1.0 Ratio of effective length to actual length of column about major axis.

ELY 1.0 Ratio of effective length to actual length of column about minor axis.

TORSION 0.0 A value of 0.0 means torsion to be considered in beam design. A value of 1.0 means torsion to be neglected in beam design.

SPSMAIN 25 mm Minimum clear distance between main reinforcing bars in beam and column. For column centre to centre distance between main bars cannot exceed 300mm.

SFACE 0.0 Face of support location at start of beam. It is used to check against shear at the face of the support in beam design. The parameter can also be used to check against shear at any point from the start of the member.

Page 387: International Design Codes

Section 8A 8-11

Table 8A.1 Indian Concrete Design IS456 Parameters

Parameter Name Default Value Description

EFACE 0.0 Face of support location at end of beam. The parameter can also be used to check against shear at any point from the end of the member. (Note: Both SFACE and EFACE are input as positive numbers).

ENSH 0.0 Perform shear check against enhanced shear strength as per Cl. 40.5 of IS456:2000.

ENSH = 1.0 means ordinary shear check to be performed ( no enhancement of shear strength at sections close to support)

For ENSH = a positive value(say x ), shear strength will be enhanced up to a distance x from the start of the member. This is used only when a span of a beam is subdivided into two or more parts. (Refer note )

For ENSH = a negative value(say –y), shear strength will be enhanced up to a distance y from the end of the member. This is used only when a span of a beam is subdivided into two or more parts.(Refer note)

If default value (0.0) is used the program will calculate Length to Overall Depth ratio. If this ratio is greater than 2.5, shear strength will be enhanced at sections (<2d) close to support otherwise ordinary shear check will be performed.

RENSH 0.0 Distance of the start or end point of the member

from its nearest support. This parameter is used only when a span of a beam is subdivided into two or more parts. (Refer note)

Bar combination has been introduced for detailing. Please refer section 8A.8 for details.

Note: Value of ENSH parameter (other than 0.0 and 1.0) is used only when the span of a beam is subdivided into two or more parts. When this condition is aroused RENSH parameter is also to be used.

Page 388: International Design Codes

Concrete Design Per IS456

Section 8A 8-12

The span of the beam is subdivided four parts, each of length L metre. The shear strength will be enhanced up to X metre from both supports. The input should be the following: Steps: ENSH L MEMB 1 => Shear strength will be enhanced

throughout the length of the member 1, positive sign indicates length measured from start of the member

ENSH (X-L) MEMB 2 => Shear strength will be enhanced up to a

length (X-L) of the member 2, length measured from the start of the member

ENSH –L MEMB 4 => Shear strength will be enhanced

throughout the length of the member 4, negative sign indicates length measured from end of the member

ENSH –(X-L) MEMB 3 => Shear strength will be enhanced up to

a length (X-L) of the member 3, length measured from the end of the member

RENSH L MEMB 2 3 => Nearest support lies at a distance L

from both the members 2 and 3.

Page 389: International Design Codes

Section 8A 8-13

DESIGN BEAM 1 TO 4 => This will enhance the shear strength up to length X from both ends of the beam consisting of members 1 to 4 and gives spacing accordingly.

At section = y1 from start of member 1 av = y1 At section = y2 from the start of member 2 av = y2+L At section = y3 from the end of member 3 av = y3+L At section = y4 from end of member 4 av = y4 where τc, enhanced = 2dτc/av At section 0.0, av becomes zero. Thus enhanced shear strength will become infinity. However for any section shear stress cannot exceed τc, max. Hence enhanced shear strength is limited to a maximum value of τc, max.

8A.8 Bar Combination

Initially, the program selects only one bar to calculate the number of bars required and area of steel provided at each section along the length of the beam. Now, two bar diameters can be specified to calculate a combination of each bar to be provided at each section. The syntax for bar combination is given below.

START BAR COMBINATION MD1 <bar diameter> MEMB <member list> MD2 <bar diameter> MEMB <member list> END BAR COMBINATION

Page 390: International Design Codes

Concrete Design Per IS456

Section 8A 8-14 MD2 bar diameter should be greater than MD1 bar diameter. The typical output for bar combination is shown below:

OUTPUT FOR BAR COMBINATION ---------------------------------------------------------------------------- | M A I N R E I N F O R C E M E N T | ---------------------------------------------------------------------------- SECTION | 0.0- 2166.7 | 2166.7- 6500.0 | 6500.0- 8666.7 | | mm | mm | mm | ---------------------------------------------------------------------------- TOP | 6-20í + 1-25í | 2-20í + 1-25í | 2-20í | | in 2 layer(s) | in 1 layer(s) | in 1 layer(s) | Ast Reqd| 2330.22 | 1029.90 | 582.55 | Prov| 2376.79 | 1119.64 | 628.57 | Ld (mm) | 940.2 | 940.2 | 940.2 | ---------------------------------------------------------------------------- BOTTOM | 4-20í | 2-20í | 2-20í | | in 1 layer(s) | in 1 layer(s) | in 1 layer(s) | Ast Reqd| 1165.11 | 582.55 | 582.55 | Prov| 1257.14 | 628.57 | 628.57 | Ld (mm) | 940.2 | 940.2 | 940.2 | ----------------------------------------------------------------------------

The beam length is divided into three parts, two at its ends and one at span. Ld gives the development length to be provided at the two ends of each section.

8A.9 Wall Design in accordance with IS 456-2000

Design of walls in accordance with IS 456-2000 is available in STAAD.Pro. Design is performed for in-plane shear, in-plane and out-of-plane bending and out-of-plane shear. The wall has to be modeled using STAAD’s Surface elements. The use of the Surface element enables the designer to treat the entire wall as one entity. It greatly simplifies the modeling of the wall and adds clarity to the analysis and design output. The results are presented in the context of the entire wall rather than individual finite elements thereby allowing users to quickly locate required information. The program reports shear wall design results for each load case/combination for user specified number of sections given by SURFACE DIVISION (default value is 10) command. The shear

Page 391: International Design Codes

Section 8A 8-15

wall is designed at these horizontal sections. The output includes the required horizontal and vertical distributed reinforcing, the concentrated (in-plane bending) edge reinforcing and the link required for out-of-plane shear. General format: START SHEARWALL DESIGN CODE INDIAN FYMAIN f1 FC f2 HMIN f3 HMAX f4 VMIN f5 VMAX f6 EMIN f7 EMAX f8 LMIN f9 LMAX f10 CLEAR f11 TWOLAYERED f12 KSLENDER f13 DESIGN SHEARWALL LIST shearwall-list END

Page 392: International Design Codes

Concrete Design Per IS456

Section 8A 8-16 The following table explains the parameters used in the shear wall design.

SHEAR WALL DESIGN PARAMETERS

Parameter Name Default Value

Description

FYMAIN 415 Mpa Yield strength of steel, in current units.

FC 30 Mpa Compressive strength of concrete, in current units.

HMIN 8 Minimum size of horizontal reinforcing bars (range 6 mm – 36 mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

HMAX 36 Maximum size of horizontal reinforcing bars (range 6 mm – 36 mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

VMIN 8 Minimum size of vertical reinforcing bars (range 6mm – 36mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

VMAX 36 Maximum size of vertical reinforcing bars (range 6mm – 36mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

EMIN 8 Minimum size of vertical reinforcing bars located in edge zones (range 6mm – 36mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

EMAX 36 Maximum size of vertical reinforcing bars located in edge zones (range 6mm – 36mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

LMIN 6 Minimum size of links (range 6mm – 16mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

Page 393: International Design Codes

Section 8A 8-17

SHEAR WALL DESIGN PARAMETERS

Parameter Name Default Value

Description

LMAX 16 Maximum size of links (range 6mm – 16mm). If input is 6 (integer number) the program will assume 6 mm diameter bar.

CLEAR 25 mm Clear concrete cover, in current units. TWOLAYERED 0 Reinforcement placement mode:

0 - single layer, each direction 1 - two layers, each direction

KSLENDER 1.0 Slenderness factor for finding effective height. Table 6

The following example illustrates the input for the definition of shear wall and design of the wall. Example

.

. SET DIVISION 12 SURFACE INCIDENCES 2 5 37 34 SUR 1 19 16 65 68 SUR 2 11 15 186 165 SUR 3 10 6 138 159 SUR 4 . . . SURFACE PROPERTY 1 TO 4 THI 18 SUPPORTS 1 7 14 20 PINNED 2 TO 5 GEN PIN 6 TO 10 GEN PIN

Page 394: International Design Codes

Concrete Design Per IS456

Section 8A 8-18

11 TO 15 GEN PIN 19 TO 16 GEN PIN . . . SURFACE CONSTANTS E 2.17185e+007 POISSON 0.17 DENSITY 23.5616 ALPHA 1e-005 . . START SHEARWALL DES CODE INDIAN UNIT NEW MMS FC 25 FYMAIN 415 TWO 1 VMIN 12 HMIN 12 EMIN 12 DESIGN SHEA LIST 1 TO 4 END

Notes 1. Command SET DIVISION 12 indicates that the surface

boundary node-to-node segments will be subdivided into 12 fragments prior to finite element mesh generation.

2. Four surfaces are defined by the SURFACE INCIDENCES command.

3. The SUPPORTS command includes the new support generation routine. For instance, the line 2 TO 5 GEN PIN assigns pinned supports to all nodes between nodes 2 and 5. As the node-to-node distances were previously subdivided by the SET DIVISION 12 command, there will be an additional 11 nodes between nodes 2 and 5. As a result, all 13 nodes will be assigned pinned supports. Please note that

Page 395: International Design Codes

Section 8A 8-19

the additional 11 nodes are not individually accessible to the user. They are created by the program to enable the finite element mesh generation and to allow application of boundary constraints.

4. Surface thickness and material constants are specified by the SURFACE PROPERTY and SURFACE CONSTANTS, respectively.

5. The shear wall design commands are listed between lines START SHEARWALL DES and END. The CODE command selects the design code that will be the basis for the design. For Indian code the parameter is INDIAN. The DESIGN SHEARWALL LIST command is followed by a list of previously defined Surface elements intended as shear walls and/or shear wall components.

Technical Overview The program implements provisions of section 32 of IS 456-2000 and relevant provisions as referenced therein, for all active load cases. The following steps are performed for each of the horizontal sections of the wall. Checking of slenderness limit The slenderness checking is done as per clause no. 32.2.3. The default effective height is the height of the wall. User can change the effective height. The limit for slenderness is taken as 30. Design for in-plane bending and vertical load (denoted by Mz & Fy in the shear wall force output) Walls when subjected to combined in-plane horizontal and vertical forces produce in-plane bending in conjunction with vertical load. According to clause no. 32.3.1, in-plane bending may be neglected in case a horizontal cross section of the wall is always under compression due combined effect of horizontal and vertical loads. Otherwise, the section is checked for combined vertical load and in-plane moment as column with axial load and uni-axial bending. For this purpose, the depth is taken as 0.8 x horizontal length of

Page 396: International Design Codes

Concrete Design Per IS456

Section 8A 8-20 wall and breadth is the thickness of the wall. The reinforcement is concentrated at both ends (edges) of the wall. The edge reinforcement is assumed to be distributed over a length of 0.2 times horizontal length on each side. Minimum reinforcements are according to clause no. 32.5.(a). Maximum 4% reinforcement is allowed. Design for in-plane shear (denoted by Fxy in the shear wall force output) By default, the program does not design only at the critical section but at all the horizontal sections. By suitable use of the surface division command, design at critical section as per clause no. 32.4.1 can be performed. The design for in-plane shear is done as per clause no. 32.4. The nominal shear stress is calculated as per clause no. 32.4.2 and it is checked with the maximum allowable shear stress as per clause no. 32.4.2.1. The design shear strength of concrete is calculated as per clause no. 32.4.3. Design of shear reinforcement is done as per clause no. 32.4.4. Minimum reinforcements are as per clause no. 32.5. Design for vertical load and out-of-plane vertical bending (denoted by Fy and My respectively in the shear wall force output) Apart from the in-plane bending and horizontal shear force, the wall is also subjected to out-of-plane bending in the vertical and horizontal directions. The part of the wall which is not having edge reinforcements (i.e. a zone of depth 0.6 x Length of the wall), is designed again as column under axial load (i.e. vertical load) and out-of-plane vertical bending. The minimum reinforcements and maximum allowable spacings of reinforcements are as per clause no. 32.5

Page 397: International Design Codes

Section 8A 8-21

Design for out-of-plane horizontal bending (denoted by Mx in the shear wall force output) The horizontal reinforcement which is already provided for in-plane shear is checked against out-of-plane horizontal bending. The wall is assumed as a slab for this purpose. Design for out-of-plane shears (denoted by Qx and Qy in the shear wall force output) The out-of-plane shear arises from out-of-plane loading. The nominal shear stresses are calculated as per clause no. 40.1. Maximum allowable shear stresses are as per table 20. For shear force in the vertical direction, shear strength of concrete section is calculated as per section 4.1 of SP 16 : 1980 considering vertical reinforcement as tension reinforcement. Similarly, for shear force in the horizontal direction, shear strength of concrete section is calculated considering horizontal reinforcement as tension reinforcement. Shear reinforcements in the form of links are computed as per the provisions of clause no. 40.4. Shear Wall Design With Opening The Surface element has been enhanced to allow design of shear walls with rectangular openings. The automatic meshing algorithm has been improved to allow variable divisions along wall and opening(s) edges. Design and output are available for user selected locations. Description Shear walls modeled in STAAD.Pro may include an unlimited number of openings. Due to the presence of openings, the wall may comprise up with different wall panels.

Page 398: International Design Codes

Concrete Design Per IS456

Section 8A 8-22 1. Shear wall set-up

Definition of a shear wall starts with a specification of the surface element perimeter nodes, meshing divisions along node-to-node segments, opening(s) corner coordinates, and meshing divisions of four edges of the opening(s).

SURFACE INCIDENCE n1, ..., ni SURFACE s DIVISION sd1, ..., sdj - RECOPENING x1 y1 z1 x2 y2 z2 x3 y3 z3 x4 y4 z4 DIVISION od1, ..., odk

where: n1, ..., ni - node numbers on the perimeter of the shear wall, s - surface ordinal number, sd1, ..., sdj - number of divisions for each of the node-to-node

distance on the surface perimeter, x1 y1 z1 (...) - coordinates of the corners of the opening, od1, ..., odk - divisions along edges of the opening. Note: If the sd1, ..., sdj or the od1, ..., odk list does not include all node-to-node segments, or if any of the numbers listed equals zero, then the corresponding division number is set to the default value (=10, or as previously input by the SET DIVISION command). Default locations for stress/force output, design, and design output are set as follows:

SURFACE DIVISION X xd SURFACE DIVISION Y yd

Page 399: International Design Codes

Section 8A 8-23

where: xd - number of divisions along X axis, yd - number of divisions along Y axis. Note: xd and yd represent default numbers of divisions for each edge of the surface where output is requested. The output is provided for sections located between division segments. For example, if the number of divisions = 2, then the output will be produced for only one section (at the center of the edge).

2. Stress/force output printing Values of internal forces may be printed out for any user-defined section of the wall. The general format of the command is as follows:

PRINT SURFACE FORCE (ALONG ξ) (AT a) (BETWEEN d1, d2) LIST s1, ...,si

where: ξ - local axis of the surface element (X or Y), a - distance along the ξ axis from start of the member

to the full cross-section of the wall, d1, d2 - coordinates in the direction orthogonal to ξ ,

delineating a fragment of the full cross-section for which the output is desired. **

s1, ...,si - list of surfaces for output generation ** The range currently is taken in terms of local axis. If the local axis is directed away from the surface, the negative range is to be entered.

Page 400: International Design Codes

Concrete Design Per IS456

Section 8A 8-24 Note: If command ALONG is omitted, direction Y (default) is assumed. If command AT is omitted, output is provided for all sections along the specified (or default) edge. Number of sections will be determined from the SURFACE DIVISION X or SURFACE DIVISION Y input values. If the BETWEEN command is omitted, the output is generated based on full cross-section width.

3. Definition of wall panels Input syntax for panel definition is as follows:

START PANEL DEFINITION SURFACE i PANEL j ptype x1 y1 z1 x2 y2 z2 x3 y3 z3 x4 y4 z4 END PANEL DEFINITION

where: i - ordinal surface number, j - ordinal panel number, ptype - panel type, one of: WALL, COLUMN, BEAM x1 y1 z1 (...) - coordinates of the corners of the panel,

4. Shear wall design The program implements different provisions of design of walls as per code BS 8110. General syntax of the design command is as follows:

START SHEARWALL DESIGN (...) DESIGN SHEARWALL (AT c) LIST s END SHEARWALL DESIGN

Page 401: International Design Codes

Section 8A 8-25

Note: If the command AT is omitted, the design proceeds for all cross sections of the wall or panels, as applicable, defined by the SURFACE DIVISION X or SURFACE DIVISION Y input values. a. No panel definition. Design is performed for the specified horizontal full cross-section, located at a distance c from the origin of the local coordinates system. If opening is found then reinforcement is provided along sides of openings. The area of horizontal and vertical bars provided along edges of openings is equal to that of the respective interrupted bars. b. Panels have been defined. Only wall panel design is supported in Indian code.

Page 402: International Design Codes

Concrete Design Per IS456

Section 8A

8-26

Page 403: International Design Codes

8-27

Concrete Design Per IS13920

Section 8A1

8A1.1 Design Operations

Earthquake motion often induces force large enough to cause inelastic deformations in the structure. If the structure is brittle, sudden failure could occur. But if the structure is made to behave ductile, it will be able to sustain the earthquake effects better with some deflection larger than the yield deflection by absorption of energy. Therefore ductility is also required as an essential element for safety from sudden collapse during severe shocks. STAAD has the capabilities of performing concrete design as per IS 13920. While designing it satisfies all provisions of IS 456 – 2000 and IS 13920 for beams and columns.

8A1.2 Section Types for Concrete Design

The following types of cross sections for concrete members can be designed. For Beams Prismatic (Rectangular & Square) & T-shape For Columns Prismatic (Rectangular, Square and Circular)

Page 404: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-28

8A1.3 Design Parameters

The program contains a number of parameters that are needed to perform design as per IS 13920. It accepts all parameters that are needed to perform design as per IS:456. Over and above it has some other parameters that are required only when designed is performed as per IS:13920. Default parameter values have been selected such that they are frequently used numbers for conventional design requirements. These values may be changed to suit the particular design being performed. Table 8A1.1 of this manual contains a complete list of the available parameters and their default values. It is necessary to declare length and force units as Millimeter and Newton before performing the concrete design.

8A1.4 Beam Design

Beams are designed for flexure, shear and torsion. If required the effect of the axial force may be taken into consideration. For all these forces, all active beam loadings are prescanned to identify the critical load cases at different sections of the beams. The total number of sections considered is 13. All of these sections are scanned to determine the design force envelopes. For design to be performed as per IS:13920 the width of the member shall not be less than 200mm(Clause 6.1.3). Also the member shall preferably have a width-to depth ratio of more than 0.3 (Clause 6.1.2). The factored axial stress on the member should not exceed 0.1fck (Clause 6.1.1) for all active load cases. If it exceeds allowable axial stress no design will be performed.

Page 405: International Design Codes

Section 8A1 8-29

Design for Flexure

Design procedure is same as that for IS 456. However while designing following criteria are satisfied as per IS-13920:

1. The minimum grade of concrete shall preferably be M20. (Clause 5.2)

2. Steel reinforcements of grade Fe415 or less only shall be used. (Clause 5.3)

3. The minimum tension steel ratio on any face, at any section, is given by

ρmin = 0.24√fck/fy (Clause 6.2.1b) The maximum steel ratio on any face, at any section, is given by ρmax = 0.025 (Clause 6.2.2)

4. The positive steel ratio at a joint face must be at least equal to half the negative steel at that face. (Clause 6.2.3)

5. The steel provided at each of the top and bottom face, at any section, shall at least be equal to one-fourth of the maximum negative moment steel provided at the face of either joint. (Clause 6.2.4) Design for Shear

The shear force to be resisted by vertical hoops is guided by the Clause 6.3.3 of IS 13920:1993 revision. Elastic sagging and hogging moments of resistance of the beam section at ends are considered while calculating shear force. Plastic sagging and hogging moments of resistance can also be considered for shear design if PLASTIC parameter is mentioned in the input file. (Refer Table 8A1.1) Shear reinforcement is calculated to resist both shear forces and torsional moments. Procedure is same as that of IS 456.

Page 406: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-30 The following criteria are satisfied while performing design for shear as per Cl. 6.3.5 of IS-13920: The spacing of vertical hoops over a length of 2d at either end of the beam shall not exceed a) d/4 b) 8 times the diameter of the longitudinal bars In no case this spacing is less than 100 mm. The spacing calculated from above, if less than that calculated from IS 456 consideration is provided. Beam Design Output The default design output of the beam contains flexural and shear reinforcement provided at 5 equally spaced sections along the length of the beam. User has option to get a more detail output. All beam design outputs are given in IS units. An example of rectangular beam design output with the default output option (TRACK 1.0) is presented below:

Page 407: International Design Codes

Section 8A1 8-31

============================================================================ B E A M N O. 11 D E S I G N R E S U L T S

M20 Fe415 (Main) Fe415 (Sec.) LENGTH: 3500.0 mm SIZE: 250.0 mm X 350.0 mm COVER: 30.0 mm

DESIGN LOAD SUMMARY (KN MET) ---------------------------------------------------------------------------- SECTION |FLEXTURE (Maxm. Sagging/Hogging moments)| SHEAR (in mm) | P MZ MX Load Case | VY MX Load Case ---------------------------------------------------------------------------- 0.0 | 0.00 0.00 0.00 4 | 17.67 0.00 4

| 0.00 -2.74 0.00 5 | 291.7 | 0.00 1.15 0.00 5 | 16.26 0.00 4

| 0.00 0.00 0.00 4 | 583.3 13.97 0.00 4 | 0.00 4.61 0.00 5 |

| 0.00 0.00 0.00 4 | 875.0 | 0.00 7.44 0.00 5 | 10.78 0.00 4

| 0.00 0.00 0.00 4 | 1166.7 | 0.00 9.41 0.00 5 | 6.69 0.00 4

| 0.00 0.00 0.00 4 | 1458.3 | 0.00 10.33 0.00 5 | 1.10 0.00 5

| 0.00 0.00 0.00 4 | 1750.0 | 0.00 9.98 0.00 5 | -3.60 0.00 5

| 0.00 0.00 0.00 4 | 2041.7 | 0.00 8.23 0.00 5 | -10.02 0.00 4

| 0.00 0.00 0.00 4 | 2333.3 | 0.00 5.21 0.00 5 | -15.00 0.00 4

| 0.00 0.00 0.00 4 | 2625.0 | 0.00 1.14 0.00 5 | -19.08 0.00 4

| 0.00 0.00 0.00 4 | 2916.7 | 0.00 0.00 0.00 4 | -22.27 0.00 4

| 0.00 -3.79 0.00 5 | 3208.3 | 0.00 0.00 0.00 4 | -24.57 0.00 4

| 0.00 -9.35 0.00 5 | 3500.0 | 0.00 0.00 0.00 4 | -25.97 0.00 4

| 0.00 -15.34 0.00 5 | *** DESIGN SHEAR FORCE AT SECTION 0.0 IS 68.60 KN.

- CLAUSE 6.3.3 OF IS-13920

*** DESIGN SHEAR FORCE AT SECTION 3500.0 IS 75.24 KN. - CLAUSE 6.3.3 OF IS-

13920 ----------------------------------------------------------------------------

SUMMARY OF REINF. AREA (Sq.mm) ---------------------------------------------------------------------------- SECTION 0.0 mm 875.0 mm 1750.0 mm 2625.0 mm 3500.0 mm ---------------------------------------------------------------------------- TOP 226.30 0.00 0.00 0.00 226.30 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) BOTTOM 0.00 203.02 203.02 203.02 0.00 REINF. (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) (Sq. mm) ----------------------------------------------------------------------------

SUMMARY OF PROVIDED REINF. AREA ---------------------------------------------------------------------------- SECTION 0.0 mm 875.0 mm 1750.0 mm 2625.0 mm 3500.0 mm ---------------------------------------------------------------------------- TOP 3-10í 2-10í 2-10í 2-10í 3-10í REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) BOTTOM 2-12í 2-12í 2-12í 2-12í 2-12í REINF. 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) 1 layer(s) SHEAR 2 legged 8í 2 legged 8í 2 legged 8í 2 legged 8í 2 legged 8í REINF. @ 100 mm c/c @ 150 mm c/c @ 150 mm c/c @ 150 mm c/c @ 100 mm c/c ---------------------------------------------------------------------------- ============================================================================

Page 408: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-32

8A1.5 Column Design

Columns are designed for axial forces and biaxial moments per IS 456:2000. Columns are also designed for shear forces as per Clause 7.3.4. All major criteria for selecting longitudinal and transverse reinforcement as stipulated by IS:456 have been taken care of in the column design of STAAD. However following clauses have been satisfied to incorporate provisions of IS 13920: 1. The minimum grade of concrete shall preferably be M20.

(Clause 5.2)

2. Steel reinforcements of grade Fe415 or less only shall be used. (Clause 5.3)

3. The minimum dimension of column member shall not be less than 200 mm. For columns having unsupported length exceeding 4m, the shortest dimension of column shall not be less than 300 mm. (Clause 7.1.2)

4. The ratio of the shortest cross-sectional dimension to the perpendicular dimension shall preferably be not less than 0.4. (Clause 7.1.3)

5. The spacing of hoops shall not exceed half the least lateral dimension of the column, except where special confining reinforcement is provided. (Clause 7.3.3)

6. Special confining reinforcement shall be provided over a length lo from each joint face, towards mid span, and on either side of any section, where flexural yielding may occur. The length lo shall not be less than a) larger lateral dimension of the member at the section where yielding occurs, b) 1/6 of clear span of the member, and c) 450 mm. (Clause 7.4.1)

7. The spacing of hoops used as special confining reinforcement shall not exceed ¼ of minimum member dimension but need not be less than 75 mm nor more than 100 mm. (Clause 7.4.6)

Page 409: International Design Codes

Section 8A1 8-33

8. The area of cross-section of hoops provided are checked against the provisions for minimum area of cross-section of the bar forming rectangular, circular or spiral hoops, to be used as special confining reinforcement. (Clause 7.4.7 and 7.4.8)

Column Design Output Default column design output (TRACK 0.0) contains the reinforcement provided by STAAD and the capacity of the section. With the option TRACK 1.0, the output contains intermediate results such as the design forces, effective length coefficients, additional moments etc. A special output TRACK 9.0 is introduced to obtain the details of section capacity calculations. All design output is given in SI units. An example of a column design output (with option TRACK 1.0) is given below. ============================================================================ C O L U M N N O. 3 D E S I G N R E S U L T S M20 Fe415 (Main) Fe415 (Sec.) LENGTH: 3000.0 mm CROSS SECTION: 350.0 mm X 400.0 mm COVER: 40.0 mm ** GUIDING LOAD CASE: 5 END JOINT: 2 SHORT COLUMN DESIGN FORCES (KNS-MET) ----------------------- DESIGN AXIAL FORCE (Pu) : 226.7

About Z About Y INITIAL MOMENTS : 0.64 146.28 MOMENTS DUE TO MINIMUM ECC. : 4.53 4.53 SLENDERNESS RATIOS : - - MOMENTS DUE TO SLENDERNESS EFFECT : - - MOMENT REDUCTION FACTORS : - - ADDITION MOMENTS (Maz and May) : - - TOTAL DESIGN MOMENTS : 4.53 146.28 ** GUIDING LOAD CASE: 5 Along Z Along Y DESIGN SHEAR FORCES : 43.31 76.08 REQD. STEEL AREA : 3313.56 Sq.mm. MAIN REINFORCEMENT : Provide 12 - 20 dia. (2.69%, 3769.91 Sq.mm.) (Equally distributed) CONFINING REINFORCEMENT : Provide 10 mm dia. rectangular ties @ 85 mm c/c

over a length 500.0 mm from each joint face towards midspan as per Cl. 7.4.6 of IS-13920. TIE REINFORCEMENT : Provide 10 mm dia. rectangular ties @ 175 mm c/c SECTION CAPACITY (KNS-MET) -------------------------- Puz : 2261.52 Muz1 : 178.71 Muy1 : 150.75 INTERACTION RATIO: 1.00 (as per Cl. 39.6, IS456:2000) ============================================================================ ********************END OF COLUMN DESIGN RESULTS********************

Page 410: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-34

Table 8A1.1 Indian Concrete Design IS13920 Parameters

Parameter Name

Default Value Description

FYMAIN 415 N/mm2 Yield Stress for main reinforcing steel.

FYSEC 415 N/mm2 Yield Stress for secondary reinforcing steel.

FC 30 N/mm2 Concrete Yield Stress.

CLEAR 25 mm

40 mm

For beam members.

For column members

MINMAIN 10 mm Minimum main reinforcement bar size.

MAXMAIN 60 mm Maximum main reinforcement bar size.

MINSEC 8 mm Minimum secondary reinforcement bar size.

MAXSEC 12 mm Maximum secondary reinforcement bar size.

BRACING 0.0 BEAM DESIGN

A value of 1.0 means the effect of axial force will be taken into account for beam design.

COLUMN DESIGN

A value of 1.0 means the column is unbraced about major axis.

A value of 2.0 means the column is unbraced about minor axis.

A value of 3.0 means the column is unbraced about both axis.

RATIO 4.0 Maximum percentage of longitudinal reinforcement in columns.

RFACE 4.0 A value of 4.0 means longitudinal reinforcement in column is arranged equally along 4 faces.

A value of 2.0 invokes 2 faced distribution about major axis.

A value of 3.0 invokes 2 faced distribution about minor axis.

Page 411: International Design Codes

Section 8A1 8-35

Table 8A1.1 Indian Concrete Design IS13920 Parameters

Parameter Name

Default Value Description

WIDTH ZD Width to be used for design. This value defaults to ZD as provided under MEMBER PROPERTIES.

DEPTH YD Total depth to be used for design. This value defaults to YD as provided under MEMBER PROPERTIES.

ELZ 1.0 Ratio of effective length to actual length of column about major axis.

ELY 1.0 Ratio of effective length to actual length of column about minor axis.

REINF 0.0 Tied column. A value of 1.0 will mean spiral reinforcement.

TORSION 0.0 A value of 0.0 means torsion to be considered in beam design.

A value of 1.0 means torsion to be neglected in beam design.

TRACK 0.0 BEAM DESIGN:

For TRACK = 0.0, output consists of reinforcement details at START, MIDDLE and END.

For TRACK = 1.0, critical moments are printed in addition to TRACK 0.0 output.

For TRACK = 2.0, required steel for intermediate sections defined by NSECTION are printed in addition to TRACK 1.0 output.

COLUMN DESIGN:

With TRACK = 0.0, reinforcement details are printed.

With TRACK = 1.0, column interaction analysis results are printed in addition to TRACK 0.0 output.

With TRACK = 2.0, a schematic interaction diagram and intermediate interaction values are printed in addition to TRACK 1.0 output.

Page 412: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-36

Table 8A1.1 Indian Concrete Design IS13920 Parameters

Parameter Name

Default Value Description

SPSMAIN 25 mm Minimum clear distance between main reinforcing bars in beam and column. For column centre to centre distance between main bars cannot exceed 300mm.

SFACE 0.0 Face of support location at start of beam. It is used to check against shear at the face of the support in beam design. The parameter can also be used to check against shear at any point from the start of the member.*

EFACE 0.0 Face of support location at end of beam. The parameter can also be used to check against shear at any point from the end of the member. (Note: Both SFACE and EFACE are input as positive numbers).*

ENSH 0.0 Perform shear check against enhanced shear strength as per Cl. 40.5 of IS456:2000.

ENSH = 1.0 means ordinary shear check to be performed ( no enhancement of shear strength at sections close to support)

For ENSH = a positive value(say x ), shear strength will be enhanced up to a distance x from the start of the member. This is used only when a span of a beam is subdivided into two or more parts. (Refer note after Table 8A.1 )

For ENSH = a negative value(say –y), shear strength will be enhanced up to a distance y from the end of the member. This is used only when a span of a beam is subdivided into two or more parts.(Refer note after Table 8A.1)

If default value (0.0) is used the program will calculate Length to Overall Depth ratio. If this ratio is greater than 2.5, shear strength will be enhanced at sections (<2d) close to support otherwise ordinary shear check will be performed.

RENSH 0.0 Distance of the start or end point of the member from its nearest support. This

Page 413: International Design Codes

Section 8A1 8-37

Table 8A1.1 Indian Concrete Design IS13920 Parameters

Parameter Name

Default Value Description

parameter is used only when a span of a beam is subdivided into two or more parts. (Refer note after Table 8A.1)

EUDL None Equivalent u.d.l on span of the beam. This load value must be the unfactored load on span. During design the load value is multiplied by a factor 1.2. If no u.d.l is defined factored shear force due to gravity load on span will be taken as zero. No elastic or plastic moment will be calculated. Shear design will be performed based on analysis result.(Refer note)

GLD None Gravity load number to be considered for calculating equivalent u.d.l on span of the beam, in case no EUDL is mentioned in the input. This loadcase can be any static loadcase containing MEMBER LOAD on the beam which includes UNI, CON, LIN and TRAP member loading. CMOM member loading is considered only when it is specified in local direction. FLOOR LOAD is also considered.

The load can be primary or combination load. For combination load only load numbers included in load combination is considered. The load factors are ignored. Internally the unfactored load is multiplied by a factor 1.2 during design.

If both EUDL and GLD parameters are mentioned in the input mentioned EUDL will be considered in design

Note :

No dynamic (Response spectrum, 1893, Time History) and moving load cases are considered.

CMOM member loading in global direction is not considered.

UMOM member loading is not considered.

Page 414: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-38

Table 8A1.1 Indian Concrete Design IS13920 Parameters

Parameter Name

Default Value Description

PLASTIC 0.0 Default value calculates elastic hogging and sagging moments of resistance of beam at its ends.

A value of 1.0 means plastic hogging and sagging moments of resistance of beam to be calculated at its ends.

IPLM 0.0 Default value calculates elastic/plastic hogging and sagging moments of resistance of beam at its ends.

A value of 1.0 means calculation of elastic/plastic hogging and sagging moments of resistance of beam to be ignored at start node of beam. This implies no support exists at start node.

A value of -1.0 means calculation of elastic/plastic hogging and sagging moments of resistance of beam to be considered at start node of beam. . This implies support exists at start node.

A value of 2.0 means calculation of elastic/plastic hogging and sagging moments of resistance of beam to be ignored at end node of beam. This implies no support exists at end node.

A value of -2.0 means calculation of elastic/plastic hogging and sagging moments of resistance of beam to be considered at end node of beam. . This implies support exists at end node. **

IMB 0.0 Default value calculates elastic/plastic hogging and sagging moments of resistance of beam at its ends.

A value of 1.0 means calculation of elastic/plastic hogging and sagging moments of resistance of beam to be ignored at both ends of beam. This implies no support exist at either end of the member.

A value of -1.0 means calculation of

Page 415: International Design Codes

Section 8A1 8-39

Table 8A1.1 Indian Concrete Design IS13920 Parameters

Parameter Name

Default Value Description

elastic/plastic hogging and sagging moments of resistance of beam to be considered at both ends of beam. This implies support exist at both ends of the member.**

COMBINE 0.0 Default value means there will be no member combination.

A value of 1.0 means there will be no printout of sectional force and critical load for combined member in the output.

A value of 2.0 means there will be printout of sectional force for combined member in the output.

A value of 3.0 means there will be printout of both sectional force and critical load for combined member in the output. ***

HLINK Spacing of longitudinal bars measured to the

outer face

Longer dimension of the rectangular confining hoop measured to its outer face. It shall not exceed 300 mm as per Cl. 7.4.8. If hlink value as provided in the input file does not satisfy the clause the value will be internally assumed as the default one. This parameter is valid for rectangular column.

Bar combination has been introduced for detailing. Please refer section 8A1.6 for details.

* EFACE and SFACE command is not valid for member combination. ** IPLM and IMB commands are not valid for member combination. These commands are ignored for members forming physical member.

Page 416: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-40 *** The purpose of COMBINE command is the following:

1. If a beam spanning between two supports is subdivided into many

sub-beams this parameter will combine them into one member. It can also be used to combine members to form one continuous beam spanning over more than two supports.

2. When two or more members are combined during design plastic or elastic moments will be calculated at the column supports. At all the intermediate nodes (if any) this calculation will be ignored. Please note that the program only recognizes column at right angle to the beam. Inclined column support is ignored.

3. It will calculate sectional forces at 13 sections along the length of the combined member.

4. It will calculate critical loads (similar to that of Design Load Summary) for all active load cases during design. Beams will be combined only when DESIGN BEAM command is issued. The following lines should be satisfied during combination of members:

1. Members to be combined should have same sectional properties if any single span between two column supports of a continuous beam are subdivided into several members.

2. Members to be combined should have same constants (E, Poi ratio, alpha, density and beta angle)

3. Members to be combined should lie in one straight line. 4. Members to be combined should be continuous. 5. Vertical members (i.e. columns) cannot be combined. 6. Same member cannot be used more than once to form two different

combined members. 7. The maximum number of members that can be combined into one

member is 299.

Page 417: International Design Codes

Section 8A1 8-41

Note: Sectional forces and critical load for combined member output will only be available when all the members combined are successfully designed in both flexure and shear. ENSH and RENSH parameters will have to be provided (as and when necessary) even if physical member has been formed. The following lines show a standard example for design to be performed in IS 13920. STAAD SPACE UNIT METER MTON JOINT COORDINATES ………………………………….. MEMBER INCIDENCES ………………………………….. MEMBER PROPERTY INDIAN ………………………………….. CONSTANTS ……………………. SUPPORTS ……………………. DEFINE 1893 LOAD ZONE 0.05 I 1 K 1 B 1 SELFWEIGHT JOINT WEIGHT ………………………. LOAD 1 SEISMIC LOAD IN X DIR 1893 LOAD X 1 LOAD 2 SEISMIC LOAD IN Z DIR 1893 LOAD Z 1 LOAD 3 DL MEMBER LOAD …… UNI GY -5 LOAD 4 LL

Page 418: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-42 MEMBER LOAD ……. UNI GY -3 LOAD COMB 5 1.5(DL+LL) 3 1.5 4 1.5 LOAD COMB 6 1.2(DL+LL+SLX) 1 1.2 3 1.2 4 1.2 LOAD COMB 7 1.2(DL+LL-SLX) 1 1.2 3 1.2 4 -1.2 LOAD COMB 8 1.2(DL+LL+SLZ) 2 1.2 3 1.2 4 1.2 LOAD COMB 9 1.2(DL+LL-SLZ) 2 1.2 3 1.2 4 -1.2 PDELTA ANALYSIS LOAD LIST 5 TO 9 START CONCRETE DESIGN CODE IS13920 UNIT MMS NEWTON FYMAIN 415 ALL FC 20 ALL MINMAIN 12 ALL MAXMAIN 25 ALL TRACK 2.0 ALL *** Unfactored gravity load on members 110 to 112 is 8 t/m (DL+LL) i.e. 78.46 New/mm EUDL 78.46 MEMB 110 TO 112

** Members to be combined into one physical member COMBINE 3.0 MEMB 110 TO 112

*** Plastic moment considered PLASTIC 1.0 MEMB 110 TO 112 DESIGN BEAM 110 TO 112 DESIGN COLUMN ……… END CONCRETE DESIGN FINISH

Page 419: International Design Codes

Section 8A1 8-43

8A1.6 Bar Combination

Initially the program selects only one bar to calculate the number of bars required and area of steel provided at each section along the length of the beam. Now two bar diameters can be specified to calculate a combination of each bar to be provided at each section. The syntax for bar combination is given below.

START BAR COMBINATION MD1 <bar diameter> MEMB <member list> MD2 <bar diameter> MEMB <member list> END BAR COMBINATION

MD2 bar diameter should be greater than MD1 bar diameter. The typical output for bar combination is shown below:

OUTPUT FOR BAR COMBINATION ---------------------------------------------------------------------------- | M A I N R E I N F O R C E M E N T | ---------------------------------------------------------------------------- SECTION | 0.0- 2166.7 | 2166.7- 6500.0 | 6500.0- 8666.7 | | mm | mm | mm | ---------------------------------------------------------------------------- TOP | 6-20í + 1-25í | 2-20í + 1-25í | 2-20í | | in 2 layer(s) | in 1 layer(s) | in 1 layer(s) | Ast Reqd| 2330.22 | 1029.90 | 582.55 | Prov| 2376.79 | 1119.64 | 628.57 | Ld (mm) | 940.2 | 940.2 | 940.2 | ---------------------------------------------------------------------------- BOTTOM | 4-20í | 2-20í | 2-20í | | in 1 layer(s) | in 1 layer(s) | in 1 layer(s) | Ast Reqd| 1165.11 | 582.55 | 582.55 | Prov| 1257.14 | 628.57 | 628.57 | Ld (mm) | 940.2 | 940.2 | 940.2 | ----------------------------------------------------------------------------

The beam length is divided into three parts, two at its ends and one at span. Ld gives the development length to be provided at the two ends of each section.

Page 420: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-44

Sample example showing calculation of design shear force as per Clause 6.3.3

For Beam No. 1 and 2

idth b epth D

c Strength of Steel fy ic Strength of Concrete fck

r ffective Depth d 469 mm

Eudl w 6.5 N/sq. mm Length L 4000 mm Ast_Top_A 339.29 sq. mm Ast_Bot_A 226.19 sq. mm Ast_Top_B 226.19 sq. mm Ast_Bot_B 339.29 sq. mm

Section W 250 mm D 500 mm Characteristi 415 N/sq. mm Characterist 20 N/sq. mm Clear Cover 25 mm Bar Diamete 12 mm E

Page 421: International Design Codes

Section 8A1 8-45

Steps Calculation of Simple Shear Simple shear from gravity load on span =

Va = Vb = 1.2 * w * L / 2 = 15600N

Calculation of Moment Of Resistances Based On Area Of Steel Provided Sagging Moment Of Resistance of End A Mu,as =

0.87 * fy * Ast_Bot_A * d * ( 1 - Ast_Bot_A * fy / b * d * fck)

= 36768130.05 N

Hogging Moment Of Resistance of End A Mu,ah =

0.87 * fy * Ast_Top_A * d * ( 1 - Ast_Top_A * fy / b * d * fck)

= 54003057.45 N

Sagging Moment Of Resistance of End A Mu,bs =

0.87 * fy * Ast_Bot_B * d * ( 1 - Ast_Bot_B * fy / b * d * fck)

= 54003057.45 N

Hogging Moment Of Resistance of End A Mu,bh =

0.87 * fy * Ast_Top_B * d * ( 1 - Ast_Top_B* fy / b * d * fck)

= 36768130.05 N

Calculation of Shear Force Due To Formation Of Plastic Hinge At Both Ends Of The Beam Plus The Factored Gravity Load On Span

FIG1: SWAY TO RIGHT

Vur,a = Va - 1.4 [ ( Mu,as + Mu,bh ) / L ] = -10137.69104 N

Vur,b = Va + 1.4 [ ( Mu,as + Mu,bh ) / L ] = 41337.69104 N

Page 422: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-46

FIG2: SWAY TO LEFT

] = 53402.

] = - 22202.1

hear Force From Analysis At End A , Va,anl = 11.56 N

At End A, Vu,a = Max ( Va,anl, Vur,a, Vul,a) = 53402.14022 N

e From Analysis At End B , Vb,anl

esign Shear Force At End B, Vu,b = Max ( Vb Vul,b) = 41337

o. 3

Vul,a = Va + 1.4 [ ( Mu,ah + Mu,bs ) / L 14022 N

Vul,b = Va - 1.4 [ ( Mu,ah + Mu,bs ) / L 4022 N Design Shear Force

S Design Shear Force Shear Forc

= -6.44 N

D ,anl, Vur,b, .69104 N

For Beam N

idth b epth D

stic Strength of Steel fy 415c Strength of Concrete fck

r pth d

udl w 6.5 N/sq. mm Length L 3000 mm Ast_Top_A 226.19 sq. mm Ast_Bot_A 339.29 sq. mm Ast_Top_B 452.39 sq. mm Ast_Bot_B 226.19 sq. mm

Section W 300 mm D 450 mm Characteri N/sq. mm Characteristi 20 N/sq. mm Clear Cover 25 mm Bar Diamete 12 mm Effective De 419 mm E

Page 423: International Design Codes

Section 8A1 8-47

Calculation of Simple Shear Simple shear from gravity load on span =

Va = Vb = 1.2 * w * L / 2 = 11700N

Calculation of Moment Of Resistances Based On Area Of Steel Provided Sagging Moment Of Resistance of End A Mu,as =

0.87 * fy * Ast_Bot_A * d * ( 1 - Ast_Bot_A * fy / b * d * fck)

= 48452983 N

Hogging Moment Of Resistance of End A Mu,ah =

0.87 * fy * Ast_Top_A * d * ( 1 - Ast_Top_A * fy / b * d * fck)

= 32940364.5 N

Sagging Moment Of Resistance of End A Mu,bs =

0.87 * fy * Ast_Bot_B * d * ( 1 - Ast_Bot_B * fy / b * d * fck)

= 32940364.5 N

Hogging Moment Of Resistance of End A Mu,bh =

0.87 * fy * Ast_Top_B * d * ( 1 - Ast_Top_B* fy / b * d * fck) = 63326721.3 N

Calculation of Shear Force Due To Formation Of Plastic Hinge At Both Ends Of The Beam Plus The Factored Gravity Load On Span

FIG1: SWAY TO RIGHT

Vur,a = Va - 1.4 [ ( Mu,as + Mu,bh ) / L ] = -40463.862 N

Vur,b = Va + 1.4 [ ( Mu,as + Mu,bh ) / L ] = 63863.862 N

Page 424: International Design Codes

Concrete Design Per IS13920

Section 8A1 8-48

Vul,a = Va + 1.4 [ ( Mu,ah + Mu,bs ) / L ] = 42444.3402 N

ul,b = Va - 1.4 [ ( Mu,ah + Mu,bs ) / L ] = -15

rce At End A, Vu,a = Max ( Va,anl, Vur,a, Vul,a) = 42444.3402 N

hear Force From Analysis At End B , Vb,anl = -23.81 N Design Shear Force At End B, Vu,b = Max ( Vb,anl, Vur,b, Vul,b) = 63863.862 N

144.34 N V Design Shear Force Shear Force From Analysis At End A , Va,anl = -10.31 N

Design Shear Fo S

Page 425: International Design Codes

8-49

Steel Design Per IS800

Section 8B

8B.1 Design Operations

STAAD contains a broad set of facilities for designing structural members as individual components of an analyzed structure. The member design facilities provide the user with the ability to carry out a number of different design operations. These facilities may be used selectively in accordance with the requirements of the design problem. The operations to perform a design are: • Specify the members and the load cases to be considered in the

design. • Specify whether to perform code checking or member

selection. • Specify design parameter values, if different from the default

values. • Specify whether to perform member selection by optimization.

These operations may be repeated by the user any number of times depending upon the design requirements. The entire ISI steel section table is supported. Section 8B.13 describes the specification of steel sections.

Page 426: International Design Codes

Steel Design Per IS800

Section 8B 8-50

8B.2 General Comments

This section presents some general statements regarding the implementation of Indian Standard code of practice (IS:800-1984) for structural steel design in STAAD. The design philosophy and procedural logistics for member selection and code checking are based upon the principles of allowable stress design. Two major failure modes are recognized: failure by overstressing, and failure by stability considerations. The flowing sections describe the salient features of the allowable stresses being calculated and the stability criteria being used. Members are proportioned to resist the design loads without exceeding the allowable stresses and the most economic section is selected on the basis of least weight criteria. The code checking part of the program checks stability and strength requirements and reports the critical loading condition and the governing code criteria. It is generally assumed that the user will take care of the detailing requirements like provision of stiffeners and check the local effects such as flange buckling and web crippling.

8B.3 Allowable Stresses

The member design and code checking in STAAD are based upon the allowable stress design method as per IS:800 (1984). It is a method for proportioning structural members using design loads and forces, allowable stresses, and design limitations for the appropriate material under service conditions. It would not be possible to describe every aspect of IS:800 in this manual. This section, however, will discuss the salient features of the allowable stresses specified by IS:800 and implemented in STAAD. Appropriate sections of IS:800 will be referenced during the discussion of various types of allowable stresses.

Page 427: International Design Codes

Section 8B 8-51

8B.3.1 Axial Stress

Tensile Stress The allowable tensile stress, as calculated in STAAD as per IS:800 is described below. The permissible stress in axial tension, σat in MPa on the net effective area of the sections shall not exceed

σat = 0.6 fy Where, fy = minimum yield stress of steel in Mpa Compressive Stress Allowable compressive stress on the gross section of axially loaded compression members shall not exceed 0.6fy nor the permissible stress σac calculated based on the following formula: (Clause: 5.1.1)

accc y

nf fnccf nyf

σ =⋅

+0 6 1.

[( ) ( ) ]/

Where, σac = Permissible stress in axial compression, in Mpa fy = Yield stress of steel, in Mpa fcc = Elastic critical stress in compression = π2 E/λ2

E = Modulus of elasticity of steel, 2 X 105 Mpa λ=l/r = Slenderness ratio of the member, ratio of the effective

length to appropriate radius of gyration n = A factor assumed as 1.4.

Page 428: International Design Codes

Steel Design Per IS800

Section 8B 8-52

8B.3.2 Bending Stress

The allowable bending stress in a member subjected to bending is calculated based on the following formula: (Clause: 6.2.1)

σbt or σbc = 0.66 fy

Where, σbt = Bending stress in tension σbc = Bending stress in compression fy = Yield stress of steel, in MPa For an I-beam or channel with equal flanges bent about the axis of maximum strength (z-z axis), the maximum bending compressive stress on the extreme fibre calculated on the effective section shall not exceed the values of maximum permissible bending compressive stress. The maximum permissible bending compressive stress shall be obtained by the following formula: (Clause: 6.2.2)

6.2.3) :(Clause

])f y(n

)f cb(n

[

1/nf yf cb0.66σbc

+

⋅=

Where,

Yield stress of steel,fy = in Mpa = A factor assumed as 1.4.

fcb = Elastic critical st ss in bending, calculated by the following formula:

nre

cbf k X k Y cc

= +1 22

1 [ ]

Page 429: International Design Codes

Section 8B 8-53

Where,

X Y ITr D

MPyy

a coefficient to allow for reduction in thickness or breadth of flanges between points of effective lateral restraint and depends on ψ, the ratio of the total area of both flanges at the point of least bending moment tocorresponding area at the point of greatest

ra= +1 120 1

2

2 Y = 26.5x105

( / )

k1 =

the bending

k2 =

he girder, at the point of maximum bending

= on about its axis of

= he on of flange divided by width.

c1 ,c2 = m the neutral axis to the extreme fibres.

8B.3.3 Shear Stress

ges, the gross section is taken as 2/3 times the total flange area.

moment between such points of restraint.

a coefficient to allow for the inequality of flanges, and depends on ω, the ratio of the moment of inertia of the compression flange alone to that of the sum of the moment of the flanges each calculated about its own axis parallel to the y-yaxis of tmoment.

1 = effective length of compression flange

radius of gyration of the sectiryminimum strength (y-y axis)

mean thickness of the compression flange, is equal to tTarea of horizontal porti

D = overall depth of beam

respectively the lesser and greater distances frosection

Allowable shear stress calculations are based on Section 6.4 of IS:800. For shear on the web, the gross section taken into consideration consistof the product of the total depth and the web thickness. For shear parallel to the flan

Page 430: International Design Codes

Steel Design Per IS800

Section 8B 8-54

8B.3.4 Combined Stress

Members subjected to both axial and bending stresses are proportioned accordingly to section 7 of IS:800. All members subject to bending and axial compression are required to satisfy the equation of Section 7.1.1.(a) for intermediate points, and equation of Section 7.1.1.(b) for support points. For combined axial tension and bending the equation of Section 7.1.2. is required to be satisfied. Cm coefficients are calculated according to the specifications of Section 7.1.3. information regarding occurrence of sidesway can be provided through the use of parameters SSY and SSZ. In the absence of any user provided information, sidesway will be assumed.

8B.4 Design Parameters

In STAAD implementation of IS:800, the user is allowed complete control of the design process through the use of design parameters. Available design parameters to be used in conjunction with IS:800 are listed in Table 7B.1 of this section along with their default values and applicable restrictions. Users should note that when the TRACK parameter is set to 1.0 and use in conjunction with this code, allowable bending stresses in compression (FCY & FCZ), tension (FTY & FTZ), and allowable shear stress (FV) will be printed out in Member Selection and Code Check output in Mpa. When TRACK is set to 2.0, detailed design output will be provided.

8B.5 Stability Requirements

Slenderness ratios are calculated for all members and checked against the appropriate maximum values. Section 3.7 of IS:800

Page 431: International Design Codes

Section 8B 8-55

summarizes the maximum slenderness ratios for different types of members. In STAAD implementation of IS:800, appropriate maximum slenderness ratio can be provided for each member. If no maximum slenderness ratio is provided, compression members will be checked against a maximum value of 180 and tension members will be checked against a maximum value of 400.

8B.6 Truss Members

As mentioned earlier, a truss member is capable of carrying only axial forces. So in design no time is wasted in calculating bending or shear stresses, thus reducing design time considerably. Therefore, if there is any truss member in an analysis (like bracing or strut, etc.), it is wise to declare it as a truss member rather than as a regular frame member with both ends pinned.

8B.7 Deflection Check

This facility allows the user to consider deflection as a criteria in the CODE CHECK and MEMBER SELECTION processes. The deflection check may be controlled using three parameters which are described in Table 7B.1. Note that deflection is used in addition to other strength and stability related criteria. The local deflection calculation is based on the latest analysis results.

8B.8 Code Checking

The purpose of code checking is to verify whether the specified section is capable of satisfying applicable design code requirements. The code checking is based on the IS:800 (1984) requirements. Forces and moments at specified sections of the members are utilized for the code checking calculations. Sections may be specified using the BEAM parameter or the SECTION command. If no sections are specified, the code checking is based on forces and moments at the member ends.

Page 432: International Design Codes

Steel Design Per IS800

Section 8B 8-56 The code checking output labels the members as PASSed or FAILed. In addition, the critical condition (applicable IS:800 clause no.), governing load case, location (distance from the start) and magnitudes of the governing forces and moments are also printed out.

8B.9 Member Selection

STAAD is capable of performing design operations on specified members. Once an analysis has been performed, the program can select the most economical section, that is the lightest section, which satisfies the applicable code requirements. The section selected will be of the same type (I-Section, Channel etc.) as originally specified by the user. Member selection may be performed with all types of steel sections listed in Section 7B.13 and user provided tables. Selection of members, whose properties are originally provided from user specified table, will be limited to sections in the user provided table. Member selection can not be performed on members whose cross sectional properties are specified as PRISMATIC. The process of MEMBER SELECTION may be controlled using the parameters listed in Table 8B.1. It may be noted that the parameters DMAX and DMIN may be used to specify member depth constraints for selection. If PROFILE parameter is provided, the search for the lightest section is restricted to that profile. Up to three (3) profiles may be provided for any member with a section being selected from each one.

8B.10 Member Selection By Optimization

Steel section selection of the entire structure may be optimized. The optimization method utilizes a state-of-the -art numerical technique which requires automatic multiple analysis. The user may start without a specifically designated section. However, the section profile type (BEAM, COLUMN, CHANNEL, ANGLE etc.) must be specified using the ASSIGN command (see Chapter 6).

Page 433: International Design Codes

Section 8B 8-57

The optimization is based on member stiffness contributions and corresponding force distributions. An optimum member size is determined through successive analysis/design iterations. This method requires substantial computer time and hence should be used with caution.

8B.11 Tabulated Results of Steel Design

For code checking or member selection, the program produces the result in a tabulated fashion. The items in the output table are explained as follows: a) MEMBER refers to the member number for which the design

is performed b) TABLE refers to the INDIAN steel section name which has

been checked against the steel code or has been selected. c) RESULT prints whether the member has PASSED or FAILed.

If the RESULT is FAIL, there will be an asterisk (*) mark in front of the member number.

d) CRITICAL COND refers to the section of the IS:800 code

which governs the design. e) RATIO prints the ratio of the actual stresses to allowable

stresses for the critical condition. Normally a value of 1.0 or less will mean the member has passed.

f) LOADING provides the load case number which governs the design.

g) FX, MY and MZ provide the axial force, moment in local y-

axis and moment in local z-axis respectively. Although STAAD does consider all the member forces and moments (except torsion) to perform design, only FX,MY and MZ are printed since they are the ones which are of interest, in most cases.

Page 434: International Design Codes

Steel Design Per IS800

Section 8B 8-58 h) LOCATION specifies the actual distance from the start of the

member to the section where design forces govern.

i) If the parameter TRACK is set to 1.0, the program will blockout part of the table and will print allowable bending stresses in compression (FCY & FCZ) and tension (FTY & FTZ), allowable axial stress in compression (FA), and allowable shear stress (FV). When the parameter TRACK is set to 2.0 for all members parameter code values as shown in Fig 8B.1.

STAAD.Pro CODE CHECKING - (ISA )

*********************** |--------------------------------------------------------------------------| | Y PROPERTIES | |************* | IN CM UNIT | | * |=============================| ===|=== ------------ | |MEMBER 7 * | | | AX = 72.4 | | * | ST ISLB400 | | --Z AY = 32.0 | |DESIGN CODE * | | | AZ = 27.5 | | IS-800 * =============================== ===|=== SY = 86.8 | | * SZ = 965.3 | | * |<---LENGTH (ME= 3.00 --->| RY = 3.1 | |************* RZ = 16.3 | | | | 104.6( KN-METR) | |PARAMETER |L1 STRESSES | |IN NEWT MM | IN NEWT MM| |--------------- + -------------| | KL/R-Y= 95.4 | FA = 84.8 | | KL/R-Z= 18.4 + fa = 1.6 | | UNL = 3000.0 | FCZ = 116.6 | | C = 400.0 + FTZ = 165.0 | | CMY = 0.85 | FCY = 165.0 | | CMZ = 0.85 + FTY = 165.0 | | FYLD = 249.9 | L3 fbz = 108.4 | | NSF = 0.9 +---+---+---+---+---+---+---+---+---+---| fby = 0.0 | | DFF = 325.0 92.7 FV = 100.0 | | dff = 4383.0 ABSOLUTE MZ ENVELOPE | | (WITH LOAD NO.) | | | | MAX FORCE/ MOMENT SUMMARY ( KN-METR) | | ------------------------- | | | | AXIAL SHEAR-Y SHEAR-Z MOMENT-Y MOMENT-Z | | | | VALUE -23.7 61.3 0.0 0.0 104.6 | | LOCATION 0.0 0.0 0.0 0.0 0.0 | | LOADING 3 1 0 0 1 | | | |**************************************************************************| |* *| |* DESIGN SUMMARY ( KN-METR) *| |* -------------- *| |* *| |* RESULT/ CRITICAL COND/ RATIO/ LOADING/ *| | FX MY MZ LOCATION | | ====================================================== | | PASS IS-7.1.2 0.667 1 | | 9.62 T 0.0 -104.6 0.00 | | | | DEFLECTION * PASS | | RATIO: 0.074 LOADING: 3 LOCATION: 0.67 | |* *| |**************************************************************************|

Page 435: International Design Codes

Section 8B 8-59

8B.12 Indian Steel Table

This is an important feature of the program since the program will read section properties of a steel member directly from the latest ISI steel tables (as published in ISI-800). These properties are stored in memory corresponding to the section designation (e.g. ISMB250, etc.). If called for, the properties are also used for member design. Since the shear areas are built in to these tables, shear deformation is always considered for these members. Almost all ISI steel tables are available for input. A complete listing of the sections available in the built-in steel section library may be obtained using the tools of the graphical user interface. Following are the descriptions of all the types of sections available: Rolled Steel Beams (ISJB, ISLB, ISMB and ISHB). All rolled steel beam sections are available the way they are designated in the ISI handbook., e.g. ISJB225, ISWB400, etc.

20 TO 30 TA ST ISLB325

NOTE: In case of two identical beams, the heavier beam is designated with an ‘A” on the end., e.g. ISHB400 A, etc.

1 TO 5 TA ST ISHB400A

Page 436: International Design Codes

Steel Design Per IS800

Section 8B 8-60 Rolled Steel Channels (ISJC, ISLC and ISMC) All these shapes are available as listed in ISI section handbook. Designation of the channels are per the scheme used by ISI.

10 TO 20 BY 2 TA ST ISMC125 12 TA ST ISLC300

Double Channels Back to back double channels, with or without spacing between them, are available. The letter D in front of the section name will specify a double channel, e.g. D ISJC125, D ISMC75 etc.

21 22 24 TA D ISLC225

Rolled Steel Angles Both rolled steel equal angles and unequal angles are available for use in the STAAD implementation of ISI steel tables. The following example with explanations will be helpful in understanding the input procedure:

ISA 150 X 75 X 8 Angle symbol Thickness in mm Long leg length in mm Short leg length in mm

At present there is no standard way to define the local y and z axes for an angle section. The standard section has local axis system as illustrated in Fig.2.4 of this manual. The standard angle is specified as:

51 52 53 TA ST ISA60X60X6

Page 437: International Design Codes

Section 8B 8-61

This specification has the local z-axis ( i.e., the minor axis corresponding to the V-V axis specified in the steel tables. Many engineers are familiar with a convention used by some other programs in which the local y-axis is the minor axis. STAAD provides for this convention by accepting the command:

54 55 56 TA RA ISA50X30X6 (RA denotes reverse angle)

Double Angles Short leg back to back or long leg back to back double angles can be specified by inputting the word SD or LD, respectively, in front of the angle size. In case of an equal angle either LD or SD will serve the purpose. For example,

14 TO 20 TA LD ISA50X30X5 SP 1.5 23 27 TA SD ISA75X50X6

Rolled Tees (ISHT, ISST, ISLT and ISJT) All the rolled tee sections are available for input as they are specified in the ISI handbook. Following example illustrates the designated method.

1 2 5 8 TA ST ISNT100 67 68 TA ST ISST250

Pipes (Circular Hollow Sections) To designate circular hollow sections from ISI tables, use PIP followed by the numerical value of diameter and thickness of the section in mm omitting the decimal section of the value provided for diameter. Following example will illustrate the designation.

Page 438: International Design Codes

Steel Design Per IS800

Section 8B 8-62

10 15 TA ST PIP 213.2 (Specifies a 213 mm dia. pipe with 3.2 mm wall thickness)

Circular pipe sections can also be specified by providing the outside and inside diameters of the section. For example,

1 TO 9 TA ST PIPE OD 25.0ID 20.0 (specifies a pipe with outside dia. of 25 and inside dia. of 20 in current length units)

Only code checking and no member selection will be performed if this type of specification is used. Tubes (Rectangular or Square Hollow Sections) Designation of tubes from the ISI steel table is illustrated below. TUB 0 200 12.5 40 Tube Symbol Thickness in mm Height in mm Width in mm

Example:

15 TO 25 TA ST TUB 160808

Tubes, like pipes, can also be input by their dimensions (Height, Width and Thickness) and not by any table designations.

6 TA ST TUBE DT 8.0 WT 6.0 TH 0.5 is a tube that has a height of 8, a width of 6, and a wall thickness of 0.5.

Page 439: International Design Codes

Section 8B 8-63

Note that only code checking and no member selection is performed for TUBE sections specified this way. Plate And Angle Girders (With Flange Plates) All plate and angle grinders (with flange plates) are available as listed in ISI section handbook. The following example with explanations will be helpful in understanding the input procedure.

I 1000 12 A 400 12 A F B E C D A Plate and angle girder symbol. B Web plate width in mm. C Web plate thickness in mm. D Flange angle (Flange angle key below): E Flange plate width in mm. F Flange plate thickness in mm. SYMBOL ANGLE(A X B X t)(all in mm) A 150X150X18 B 200X100X15 C 200X150X18 E 200X200X18

Page 440: International Design Codes

Steel Design Per IS800

Section 8B 8-64 SINGLE JOIST WITH CHANNELS AND PLATES ON THE FLANGES TO BE USED AS GIRDERS All single joist with channel and plates on the flanges to be used as girders are available as listed in ISI section handbook. The following example with explanations will be helpful in understanding the input procedure.

IW 450 350 X 10 20 A E B D C A Joist Designation: IW450=ISWB450 B Top flange channel designation: 350=ISMC350 C Constant (always X). D Top flange plate thickness in mm. NOTE: D is 0 for no plate. E Bottom flange plate thickness in mm. NOTE: The heavier ISWB600 has been omitted, since the lighter ISWB600 is more efficient.

Page 441: International Design Codes

Section 8B 8-65

Table 8B.1 Indian Steel Design - IS : 800 Parameters

Parameter Name

Default Value Description

KY 1.0 K value in local y-axis. Usually, this is minor axis.

KZ 1.0 K value in local z-axis. Usually, this is major axis.

LY Member Length Length in local y-axis to calculate slenderness ratio.

LZ Member Length Same as above except in local z-axis (major).

FYLD 250 MPA

(36.25 KSI) Yield strength of steel.

NSF 1.0 Net section factor for tension members.

UNL Member Length Unsupported length for calculating allowable bending stress.

UNF 1.0 Same as above provided as a fraction of actual member length.

SSY 0.0 0.0 = Sidesway in local y-axis. 1.0 = No sidesway

SSZ 0.0 Same as above except in local z-axis.

CMY

CMZ

0.85 for sidesway and

calculated for no sidesway

Cm value in local y & z axes

MAIN 180 (Comp. Memb.)

Allowable Kl/r for slenderness calculations for compression members.

TMAIN 400 (Tension Memb)

Allowable Kl/r for slenderness calculations for tension members.

TRACK 0.0

0.0 = Suppress critical member stresses 1.0 = Print all critical member stresses 2.0 = Print expanded output. If there is

deflection check it will also print the governing load case number for deflection check whenever critical condition for design is not DEFLECTION. (see fig.8B.1)

DMAX 100.0 cm. Maximum allowable depth.

DMIN 0.0 cm. Minimum allowable depth.

Page 442: International Design Codes

Steel Design Per IS800

Section 8B 8-66

Table 8B.1 Indian Steel Design - IS : 800 Parameters

Parameter Name

Default Value Description

RATIO 1.0 Permissible ratio of the actual to allowable stresses.

BEAM 3.0

0.0 = design only for end moments and those at locations specified by the SECTION command.

1.0 = calculate section forces at twelfth points along the beam, design at each intermediate location and report the critical location where ratio is maximum.

PROFILE - Search for the lightest section for the profile mentioned.

DFF None

(Mandatory for deflection check)

"Deflection Length" / Maxm. allowable local deflection

DJ1 Start Joint of member

Joint No. denoting starting point for calculation of "Deflection Length" (See Note 1)

DJ2 End Joint of member

Joint No. denoting end point for calculation of "Deflection Length" (See Note 1)

NOTES: 1) "Deflection Length" is defined as the length that is used for

calculation of local deflections within a member. It may be noted that for most cases the "Deflection Length" will be equal to the length of the member. However, in some situations, the "Deflection Length" may be different. For example, refer to the figure below where a beam has been modeled using four joints and three members. Note that the "Deflection Length" for all three members will be equal to the total length of the beam in this case. The parameters DJ1 and DJ2 should be used to model this situation. Also the straight line joining DJ1 and DJ2 is used as the reference line from which local deflections are measured. Thus, for all three members here, DJ1 should be "1" and DJ2 should be "4".

Page 443: International Design Codes

Section 8B 8-67

D = Maximum local deflection for members1 2 and 3.

D

1

2 3

4

1

2 3

EXAMPLE : PARAMETERS DFF 300. ALL DJ1 1 ALL DJ2 4 ALL

2) If DJ1 and DJ2 are not used, "Deflection Length" will default

to the member length and local deflections will be measured from original member line.

3) The above parameters may be used in conjunction with other

available parameters for steel design.

8B.13 Column With Lacings And Battens

For columns with large loads it is desirable to build rolled sections at a distance and inter-connect them. The joining of element sections is done by two ways: a) Lacing and b) Batten Double channel sections (back-to-back and face-to-face) can be joined either by lacing or by batten plates having rivetted or welded connection. Table 8B.2 gives the parameters that are required for Lacing or batten design. These parameters will have to be provided in unit NEW MMS along with parameters defined in Table 8B.1.

Page 444: International Design Codes

Steel Design Per IS800

Section 8B 8-68

Table 8B.2 Indian Concrete Design IS800 Parameters

Parameter Name

Default Value Description

CTYPE 1 Type of joining

CTYPE = 1 implies single lacing with rivetted connection

CTYPE = 2 implies double lacing with rivetted connection

CTYPE = 3 implies single lacing with welded connection

CTYPE = 4 implies double lacing with welded connection

CTYPE = 5 implies batten with rivetted connection

CTYPE = 6 implies batten with welded connection

THETA 50 degree Angle of inclination of lacing bars. It should lie between 40 degree and 70 degree.

DBL 20 mm Nominal diameter of rivet

FVB 100 N/mm2 Allowable shear stress in rivet

FYB 300 N/mm2Allowable bearing stress in rivet

WMIN 6 mm Minimum thickness of weld

WSTR 108 N/mm2 Allowable welding stress

EDIST 32 mm (Rivetted Connection)

25 mm (Welded Connection)

Edge Distance

Page 445: International Design Codes

Section 8B 8-69

Table 8B.2 Indian Concrete Design IS800 Parameters

Parameter Name

Default Value Description

DCFR 0.0 0.0 implies double channel back-to-back.

1.0 Implies double channel face-to-face.

This parameter is used when member properties are defined through user provided table using GENERAL option.

COG 0.0 mm Centre of gravity of the channel. This parameter is used when member properties are defined through user provided table using GENERAL option.

SPA 0.0 mm Spacing between double channels. This parameter is used when member properties are defined through user provided table using GENERAL option.

Page 446: International Design Codes

Steel Design Per IS800

Section 8B 8-70

Page 447: International Design Codes

8-71

Steel Design Per IS802

Section 8C

8C.1 General Comments

This section presents some general statements regarding the implementation of Indian Standard code of practice (IS:802-1995 – Part 1) for structural steel design for overhead transmission line towers in STAAD. The design philosophy and procedural logistics for member selection and code checking are based upon the principles of allowable stress design. Two major failure modes are recognized: failure by overstressing, and failure by stability considerations. The flowing sections describe the salient features of the allowable stresses being calculated and the stability criteria being used. Members are proportioned to resist the design loads without exceeding the allowable stresses and the most economic section is selected on the basis of least weight criteria. The code checking part of the program checks stability and strength requirements and reports the critical loading condition and the governing code criteria.

8C.2 Allowable Stresses

The member design and code checking in STAAD are based upon the allowable stress design method as per IS:802 (1995). It is a method for proportioning structural members using design loads and forces, allowable stresses, and design limitations for the appropriate material under service conditions. This section discusses the salient features of the allowable stresses specified by IS:802 and implemented in STAAD.

Page 448: International Design Codes

Steel Design Per IS802 Section 8C 8-72

8C.2.1 Axial Stress

Tensile Stress

The allowable tensile stress, as calculated in STAAD as per IS:802 is described below. The estimated tensile stresses on the net effective sectional area in various members, multiplied by the appropriate factor of safety shall not exceed minimum guaranteed yield stress of the material. Thus, the permissible stress in axial tension, σat in MPa on the net effective area of the sections shall not exceed

σat = fy Where, fy = minimum yield stress of steel in Mpa Compressive Stress

The estimated compressive stresses in various members multiplied by the appropriate factor of safety shall not exceed the value given by the formulae described below.

Condition 1: If ⎥⎥⎦

⎢⎢⎣

⎡=⎥⎦

⎤⎢⎣⎡≤⎟

⎠⎞

⎜⎝⎛

yFtb

tb 210

lim

CCr/KL ≤

Stress Fa= yFCc

r/KL211

2

×⎥⎥⎦

⎢⎢⎣

⎡⎥⎦⎤

⎢⎣⎡− N/mm2

CCr/L > K

Page 449: International Design Codes

Section 8C 8-73

( )2

2

/ rKLE×π

Stress Fa = N/mm2

lim⎟⎠⎞

⎜⎝⎛

tb

≤yF

378Condition 2: If ⎟

⎞⎜⎛

≤ ⎠⎝ t

b when Fy is the N/mm2

formulae given in condition 1 shall be used substituting for Fy the value Fcr given by:

Fcr = y

lim

F

tb

tb677.0

677.1

⎥⎥⎥⎥

⎢⎢⎢⎢

⎟⎠⎞

⎜⎝⎛

⎟⎠⎞

⎜⎝⎛

Condition 3: ⎟⎞b

yF37

⎠⎜⎝⎛

t> 8 when F the N/mmy is n

Fcr =

2 formulae given i

ondition 1 shall be used substituting for Fc y the value Fcr given by

2

tb

65550

⎟⎠⎞

⎜⎝⎛

CC = yFE2

π In which

Where Fa = allowable unit stress in compression, Mpa Fy = minimum guaranteed yield stress of the material, Mpa

= unbraced length of the compression member in cm, and R

of elasticity of steel in N/mm2

K = restraint factor, L

= appropriate radius of gyration in cm. E = modulus

Page 450: International Design Codes

Steel Design Per IS802 Section 8C 8-74

KLr

= largest effective slenderness ratio of any unbraced segment

of the member,

fillet to the extreme fibre in mm, and .

eel

8C.3 Stability Requirements

Slenderness ratios are calculated for all members and cagainst the efault v C

b = distance from edge of thet = thickness of flange in mm

Note : The maximum permissible value of b/t for any type of stshall not exceed 25.

hecked e dappropriate maximum values. Following are th

alues used in STAAD:

ompression Members:

Members Slendernessvalue

Leg Members, ground wire peak member and lower embers of cross arms in compression

120 m

Other members carrying computed stress 200

Redundant members and those carrying nominal stresses

250

Page 451: International Design Codes

Section 8C 8-75

Slenderness ratios of compression members are determined as follows:

ELA NO.

Type of members

Value of KL/r

1 Leg sections or joint members bolted at connections in both faces

L/r

2 Members with concentric loading at both ends of the unsupported panel with values of L/r up to and including 120

L/r

3 Member with concentric loading at one end and normal eccentricities at the other end of the unsupported panel for value of L/r up to and including 120

30 + 0.75L/r

4 Members with normal framing eccentricities at both ends of the unsupported panel for values of L/r up to and including 120

60 + 0.5L/r

5 Member unrestrained against rotation at both ends of the unsupported panel for value of L/r from 120 to 200

L/r

6 Members partially restrained against rotation at one end of the unsupported panel for values of L/r over 120 and up to and including 225

28.6 + 0.762L/r

7 Members partially restrained against rotation at both ends of the unsupported panel for values of L/r over 120 and up to and including 250

46.2 + 0.615L/r

If ELA number given in the input for any particular member is such that condition for L/r ratio to fall within the specified range is not satisfied, STAAD goes on by the usual way of finding slenderness ratio using K*L/r formula.

Page 452: International Design Codes

Steel Design Per IS802 Section 8C 8-76

Tension Members:

Slenderness ratio KL/r of a member carrying axial tension only, shall not exceed 400.

8C.4 Minimum Thickness Requirement

As per Clause7.1 of IS: 802-1995 minimum thickness of different tower members shall be as follows:

Minimum Thickness, mm Members

Galvanized Painted Leg Members, ground wire peak member and lower members of cross arms in compression

5 6

Other members

4 5

8C.5 Code Checking

The purpose of code checking is to verify whether the specified section is capable of satisfying applicable design code requirements. The code checking is based on the IS:802 (1995) requirements. Axial forces at two ends of the members are utilized for the code checking calculations. The code checking output labels the members as PASSed or FAILed. In addition, the critical condition, governing load case, location (distance from the start) and magnitudes of the governing forces are also printed out. Using TRACK 9 option calculation steps are also printed.

Page 453: International Design Codes

Section 8C 8-77

8C.5.1 Design Steps

The following are the steps followed in member design. Step 1 Thickness of the member (maximum of web and flange thicknesses) is checked against minimum allowable thickness, depending upon whether the member is painted or galvanised. Step 2 If the minimum thickness criterion is fulfilled, the program determines whether the member is under compression or tension for the loadcase under consideration. Depending upon whether the member is under tension or compression the slenderness ratio of the member is calculated. This calculated ratio is checked against allowable slenderness ratio. Step 3 If the slenderness criterion is fulfilled check against allowable stress is performed. Allowable axial and tensile stresses are calculated. If the member is under tension and there is no user defined net section factor (NSF), the net section factor is calculated by the program itself (Refer Section 8C.10). Actual axial stress in the member is calculated. The ratio for actual stress to allowable stress, if less than 1.0 or user defined value, the member has passed the check. Step 4 Number of bolts required for the critical loadcase is calculated.

Page 454: International Design Codes

Steel Design Per IS802 Section 8C 8-78

8C.6 Member Selection

STAAD is capable of performing design operations on specified members. Once an analysis has been performed, the program can select the most economical section, that is the lightest section, which satisfies the applicable code requirements. The section selected will be of the same type (either angle or channel) as originally specified by the user. Member selection may be performed with all angle or channel sections and user provided tables. Selection of members, whose properties are originally provided from user specified table, will be limited to sections in the user provided table. The process of MEMBER SELECTION may be controlled using the parameters listed in Table 8B.1. It may be noted that the parameters DMAX and DMIN may be used to specify member depth constraints for selection. If PROFILE parameter is provided, the search for the lightest section is restricted to that profile. Up to three (3) profiles may be provided for any member with a section being selected from each one.

8C.7 Member Selection by Optimization

Steel section selection of the entire structure may be optimized. The optimization method utilizes a state-of-the -art numerical technique which requires automatic multiple analysis. The optimization is based on member stiffness contributions and corresponding force distributions. An optimum member size is determined through successive analysis/design iterations. This method requires substantial computer time and hence should be used with caution.

Page 455: International Design Codes

Section 8C 8-79

8C.8 Tabulated Results of Steel Design

DETAILS OF CALCULATION ---------------------- CHECK FOR MINIMUM THICKNESS --------------------------- TYPE : GALVANISED MIN. ALLOWABLE THICKNESS : 5.0 MM ACTUAL THICKNESS : 10.0 MM RESULT : PASS

Page 456: International Design Codes

Steel Design Per IS802 Section 8C 8-80

CHECK FOR SLENDERNESS RATIO --------------------------- VALUE OF L/r : 90.16 EQN. USED TO FIND KL/r : 60.0 + 0.5*L/r ACTUAL VALUE OF KL/r : 105.08 ALLOWABLE KL/r : 120.00 RESULT : PASS

CALCULATION OF ALLOWABLE STRESS -------------------------------- CRITICAL CONDITION : COMPRESSION Cc : sqrt(2*3.141592*3.141592*E/fy) : 127.22 b : LENGTH OF LEG - WEB THICKNESS - ROOT RADIUS : 150.0 - 10.0 - 11.0 : 129.0 MM (b/t)lim : 210/sqrt(fy) : 13.28 (b/t)cal : 12.90 (b/t)cal <= (b/t)lim AND KL/r <= Cc ALLOWABLE AXIAL COMP. STRESS : (1-0.5*(KL/r/Cc)*(KL/r/Cc))*fy : 164.72 MPA CHECK AGAINST PERMISSIBLE STRESS -------------------------------- DESIGN AXIAL FORCE : 250000.00 N ACTUAL AXIAL COMP. STRESS : 250000.00 / 2552.0 : 97.96 MPA RESULT : PASS BOLTING ------- BOLT DIA : 16 MM SHEARING CAP : 20.11 KN BEARING CAP : 38.40 KN BOLT CAP : 20.11 KN NO. OF BOLTS REQD. : 13

Page 457: International Design Codes

Section 8C 8-81

8C.9 Parameter Table for IS 802

Table 8C.1 Indian Steel Design - IS 802 Parameters

Parameter Name

Default Value Description

KY 1.0 K value in local y-axis. Usually, this is minor axis.

KZ 1.0 K value in local z-axis. Usually, this is major axis.

LY Member Length Unbraced length in local z-axis to calculate slenderness ratio.

LZ Member Length Unbraced length in local z-axis to calculate slenderness ratio.

FYLD 250 MPA Yield Strength of steel

MAIN 1.0 Type of member to find allowable Kl/r for slenderness calculations for members.

1.0 = Leg, Ground wire peak and lower members of cross arms in compression (KL/r = 120)

2.0 = Members carrying computed stress (KL/r = 200)

3.0 = Redundant members and members carrying nominal stresses (KL/r = 250)

4.0 = Tension members (KL/r = 400)

10.0 = Do not perform KL/r check

Any value greater than 10.0 indicates user defined allowable KL/r ratio. For this case KY and KZ values are must to find actual KL/r ratio of the member.

DMAX 100.0 cm. Maximum allowable depth.

DMIN 0.0 cm. Minimum allowable depth.

Page 458: International Design Codes

Steel Design Per IS802 Section 8C 8-82

Table 8C.1 Indian Steel Design - IS 802 Parameters

Parameter Name

Default Value Description

TRACK 0.0 0.0 = Suppress critical member stresses

1.0 = Print all critical member stresses

2.0 = Print expanded output.

9.0 = Print design calculations along with expanded output.

LEG 1.0 This parameter is meant for plain angles.

0.0 = indicates the angle is connected by shorter leg

1.0 = indicates the angle is connected by longer leg

ELA 1.0 This parameter indicates what type of end conditions is to be used. Refer Section 8C.3.

NSF 1.0 Net section factor for tension members

CNSF 0.0 This parameter indicates whether user has defined NSF or the program will calculate it.

0.0 = User has defined NSF

1.0 = Program has to calculate it

DANGLE 0.0 This parameter indicates how the pair of angles are connected to each other. This is required to find whether the angle is in single or double shear and the net section factor.

0.0 = Double angle placed back to back and connected to each side of a gusset plate

1.0 = Pair of angle placed back-to-back connected by only one leg of each angle to the same side of a gusset plate

DBL 12 mm Diameter of bolt for calculation of number of bolts and net section factor.

FVB 218 MPA Allowable shear stress in bolt

FYB 436 MPA Allowable bearing stress in bolt

Page 459: International Design Codes

Section 8C 8-83

Table 8C.1 Indian Steel Design - IS 802 Parameters

Parameter Name

Default Value Description

GUSSET 5 mm Thickness of gusset plate.

Minimum of the thicknesses of the gusset plate and the leg is used for calculation of the capacity of bolt in bearing

NHL 0.0 mm Deduction for holes.

Default value is one bolt width plus 1.5 mm. If the area of holes cut by any straight, diagonal or zigzag line across the member is different from the default value, this parameter is to be defined.

8C.10 Calculation of Net Section Factor

The procedure for calculating net section factor for angle section is described below. Single angle connected by only one leg

Anet = A1 + A2 x K1

Where A1 = net cross-sectional area of the connected leg A2 = gross cross-sectional area of the unconnected leg

And K = 1A2 A13

A13+x

x

The area of a leg of an an–

gle = Thickness of angle x (length of leg 0.5x thickness of leg)

Page 460: International Design Codes

Steel Design Per IS802 Section 8C 8-84

Pair of angles placed back-to-back connected by only one leg of each angle to the same side of a gusset plate Anet = A1 + A2 x K1 Where A1 = net cross-sectional area of the connected leg A2 = gross cross-sectional area of the unconnected leg

And K1 = A2 A15

A15+x

x

The area of a leg of an angle = Thickness of angle x (length of leg – 0.5x thickness of leg) Double angles placed back to back and connected to each side of a gusset plate Anet = gross area – deduction for holes Net Section Factor For angle section it is the ratio of the net effective area, Anet to the gross area. For channel section net section factor is taken to be 1.0.

Page 461: International Design Codes

Section 8C 8-85

8C.11 Example Problem No. 28

A transmission line tower is subjected to different loading conditions. Design some members as per IS-802 and show detailed calculation steps for the critical loading condition.

Given: End Condition = Members with normal framing

eccentricities at both ends of the unsupported panel for values of L/r up to and including 120 Diameter of the bolt = 16 mm Thickness of the gusset plate = 8 mm Net Section Factor is to be calculated.

Page 462: International Design Codes

Steel Design Per IS802 Section 8C 8-86

STAAD TRUSS INPUT WIDTH 79 UNIT METER KN JOINT COORDINATES 1 3 0 3; 2 1.2 27 1.2; 3 2.8 3 2.8; 4 2.6 6 2.6; 5 2.4 9 2.4; 6 2.2 12 2.2; 7 2 15 2; 8 1.8 18 1.8; 9 1.6 21 1.6; 10 1.4 24 1.4; 11 -3 0 3; 12 -1.2 27 1.2; 13 -2.8 3 2.8; 14 -2.6 6 2.6; 15 -2.4 9 2.4; 16 -2.2 12 2.2; 17 -2 15 2; 18 -1.8 18 1.8; 19 -1.6 21 1.6; 20 -1.4 24 1.4; 21 3 0 -3; 22 1.2 27 -1.2; 23 2.8 3 -2.8; 24 2.6 6 -2.6; 25 2.4 9 -2.4; 26 2.2 12 -2.2; 27 2 15 -2; 28 1.8 18 -1.8; 29 1.6 21 -1.6; 30 1.4 24 -1.4; 31 -3 0 -3; 32 -1.2 27 -1.2; 33 -2.8 3 -2.8; 34 -2.6 6 -2.6; 35 -2.4 9 -2.4; 36 -2.2 12 -2.2; 37 -2 15 -2; 38 -1.8 18 -1.8; 39 -1.6 21 -1.6; 40 -1.4 24 -1.4; 41 1.2 30 1.2; 42 -1.2 30 1.2; 43 1.2 30 -1.2; 44 -1.2 30 -1.2; 45 4.2 27 1.2; 46 7.2 27 1.2; 47 4.2 30 1.2; 48 4.2 27 -1.2; 49 7.2 27 -1.2; 50 4.2 30 -1.2; 51 -4.2 27 1.2; 52 -7.2 27 1.2; 53 -4.2 30 1.2; 54 -4.2 27 -1.2; 55 -7.2 27 -1.2; 56 -4.2 30 -1.2; 57 1.2 33 1.2; 58 -1.2 33 1.2; 59 1.2 33 -1.2; 60 -1.2 33 -1.2; 61 0 35 0; MEMBER INCIDENCES 1 1 3; 2 3 4; 3 4 5; 4 5 6; 5 6 7; 6 7 8; 7 8 9; 8 9 10; 9 10 2; 10 11 13; 11 13 14; 12 14 15; 13 15 16; 14 16 17; 15 17 18; 16 18 19; 17 19 20; 18 20 12; 19 13 3; 20 14 4; 21 15 5; 22 16 6; 23 17 7; 24 18 8; 25 19 9; 26 20 10; 27 12 2; 28 11 3; 29 1 13; 30 13 4; 31 3 14; 32 14 5; 33 15 4; 34 15 6; 35 16 5; 36 16 7; 37 17 6; 38 17 8; 39 18 7; 40 18 9; 41 19 8; 42 19 10; 43 20 9; 44 20 2; 45 12 10; 46 21 23; 47 23 24; 48 24 25; 49 25 26; 50 26 27; 51 27 28; 52 28 29; 53 29 30; 54 30 22; 55 3 23; 56 4 24; 57 5 25; 58 6 26; 59 7 27; 60 8 28; 61 9 29; 62 10 30; 63 2 22; 64 1 23; 65 21 3; 66 3 24; 67 23 4; 68 4 25; 69 5 24; 70 5 26; 71 6 25; 72 6 27; 73 7 26; 74 7 28; 75 8 27; 76 8 29; 77 9 28; 78 9 30; 79 10 29; 80 10 22; 81 2 30; 82 31 33; 83 33 34; 84 34 35; 85 35 36; 86 36 37; 87 37 38; 88 38 39; 89 39 40; 90 40 32; 91 23 33; 92 24 34; 93 25 35; 94 26 36; 95 27 37; 96 28 38; 97 29 39; 98 30 40; 99 22 32; 100 21 33; 101 31 23; 102 23 34; 103 33 24; 104 24 35; 105 25 34; 106 25 36; 107 26 35; 108 26 37; 109 27 36; 110 27 38; 111 28 37; 112 28 39; 113 29 38; 114 29 40; 115 30 39; 116 30 32; 117 22 40; 118 33 13; 119 34 14; 120 35 15; 121 36 16; 122 37 17; 123 38 18; 124 39 19; 125 40 20; 126 32 12; 127 31 13; 128 11 33; 129 33 14; 130 13 34; 131 34 15; 132 35 14; 133 35 16; 134 36 15; 135 36 17; 136 37 16; 137 37 18; 138 38 17; 139 38 19; 140 39 18; 141 39 20; 142 40 19; 143 40 12; 144 32 20; 145 32 44; 146 12 42; 147 2 41; 148 22 43; 149 42 41; 150 41 43; 151 43 44; 152 44 42; 153 12 41; 154 42 2; 155 22 41; 156 43 2; 157 43 32; 158 44 22; 159 12 44; 160 32 42; 161 41 47; 162 47 45; 163 45 2; 164 47 46; 165 46 45; 166 41 45; 167 43 50; 168 50 48; 169 48 22; 170 50 49; 171 49 48; 172 43 48; 173 47 50; 174 46 49; 175 45 48; 176 41 50; 177 50 46; 178 43 47; 179 47 49; 180 22 50; 181 2 47; 182 22 45; 183 2 48; 184 47 48; 185 50 45; 186 45 49; 187 48 46; 188 42 53; 189 53 51; 190 51 12; 191 53 52; 192 52 51; 193 42 51; 194 44 56; 195 56 54; 196 54 32; 197 56 55; 198 55 54; 199 44 54; 200 53 56; 201 52 55; 202 51 54; 203 42 56; 204 56 52; 205 44 53; 206 53 55; 207 32 56; 208 12 53; 209 32 51; 210 12 54; 211 53 54; 212 56 51; 213 51 55; 214 54 52; 215 44 60; 216 42 58; 217 41 57; 218 43 59; 219 60 59; 220 59 57; 221 57 58; 222 58 60; 223 44 58; 224 42 60; 225 42 57; 226 41 58; 227 44 59; 228 43 60; 229 43 57; 230 41 59; 231 60 57; 232 59 58; 235 33 3; 236 13 23; 237 34 4; 238 14 24; 239 35 5; 240 15 25; 241 36 6; 242 16 26; 243 37 7; 244 17 27; 245 38 8; 246 18 28; 247 39 9; 248 19 29; 249 40 10; 250 20 30; 251 32 2; 252 22 12; 253 44 41; 254 43 42;

Page 463: International Design Codes

Section 8C 8-87

255 60 61; 256 58 61; 257 57 61; 258 59 61; MEMBER PROPERTY INDIAN 1 TO 18 46 TO 54 82 TO 90 145 TO 148 215 TO 218 TA LD ISA200X150X18 SP 0.01 19 TO 26 28 TO 45 55 TO 62 64 TO 81 91 TO 98 100 TO 125 127 TO 144 155 156 - 159 160 223 224 229 230 235 TO 250 TA ST ISA150X150X10 27 63 99 126 149 TO 154 157 158 161 TO 214 219 TO 222 225 TO 228 231 232 251 - 252 TO 258 TA ST ISA80X50X6 CONSTANTS E 2.05e+008 ALL POISSON 0.3 ALL DENSITY 76.8195 ALL ALPHA 6.5e-006 ALL SUPPORTS 1 11 21 31 FIXED UNIT METER KG LOAD 1 VERT SELFWEIGHT Y -1 JOINT LOAD 61 FX 732 46 49 52 55 FX 153 61 FX 1280 FY -1016 FZ 160 46 49 52 55 FX 9006 FY -7844 FZ 1968 2 12 22 32 FX 4503 FY -3937 FZ 1968 LOAD 2 GWBC SELFWEIGHT Y -1 JOINT LOAD 61 FX 549 46 49 52 55 FX 1148 61 FX 515 FY -762 FZ 2342 46 49 52 55 FX 6755 FY -5906 2 12 22 32 FX 3378 FY -2953 LOAD 3 LEFT PCBC SELFWEIGHT Y -1 JOINT LOAD 61 FX 549 46 49 52 55 FX 1148 61 FX 960 FY -762 46 49 FX 6755 FY -5906 52 55 FX 4211 FY -4551 FZ 13293 2 12 22 32 FX 3378 FY -2953 LOAD 4 RIGHT PCBC SELFWEIGHT Y -1 JOINT LOAD 61 FX 549 46 49 52 55 FX 1148 61 FX 960 FY -762 52 55 FX 6755 FY -5906 46 49 FX 4211 FY -4551 FZ 13293 2 12 22 32 FX 3378 FY -2953 PERFORM ANALYSIS UNIT NEW MMS PARAMETER CODE IS802

Page 464: International Design Codes

Steel Design Per IS802 Section 8C 8-88

LY 2800 MEMB 28 LZ 2800 MEMB 28 MAIN 1.0 MEMB 1 ELA 4 MEMB 1 CNSF 1.0 MEMB 28 DBL 16 ALL GUSSET 8 ALL TRACK 9 ALL CHECK CODE MEMB 1 28

FINISH

Output of design result

Page 465: International Design Codes

Section 8C 8-89

DETAILS OF CALCULATION ---------------------- CHECK FOR MINIMUM THICKNESS --------------------------- TYPE : PAINTED MIN. ALLOWABLE THICKNESS : 6.0 MM ACTUAL THICKNESS : 18.0 MM RESULT : PASS CHECK FOR SLENDERNESS RATIO --------------------------- VALUE OF L/r : 48.49 EQN. USED TO FIND KL/r : 60.0 + 0.5*L/r ACTUAL VALUE OF KL/r : 84.25 ALLOWABLE KL/r : 120.00 RESULT : PASS CALCULATION OF ALLOWABLE STRESS --------------------------------- CRITICAL CONDITION : COMPRESSION Cc : sqrt (2*3.141592*3.141592*E/fy) : 127.24 b : LENGTH OF LEG - WEB THICKNESS - ROOT RADIUS : 200.0 - 18.0 - 13.5 : 168.5 MM (b/t)lim : 210/sqrt(fy) : 13.28 (b/t)cal : 9.36 (b/t)cal <= (b/t)lim AND KL/r <= Cc ALLOWABLE AXIAL COMP. STRESS : (1- 0.5*(KL/r/Cc)*(KL/r/Cc))*fy :

195.15 MPA CHECK AGAINST PERMISSIBLE STRESS -------------------------------- LOAD NO. : 1 DESIGN AXIAL FORCE : 1742002.38 N ACTUAL AXIAL COMP. STRESS :1742002.38 / 11952.0 : 145.75 MPA RESULT : PASS

Page 466: International Design Codes

Steel Design Per IS802 Section 8C 8-90

BOLTING ------- BOLT DIA : 16 MM SHEARING CAP : 87.66 KN BEARING CAP : 55.81 KN BOLT CAP : 55.81 KN NO. OF BOLTS REQD. : 32

Page 467: International Design Codes

Section 8C 8-91

DETAILS OF CALCULATION ---------------------- CHECK FOR MINIMUM THICKNESS --------------------------- TYPE : PAINTED MIN. ALLOWABLE THICKNESS : 6.0 MM ACTUAL THICKNESS : 10.0 MM RESULT : PASS CHECK FOR SLENDERNESS RATIO --------------------------- VALUE OF L/r : 95.56 EQN. USED TO FIND KL/r : K*L/r ACTUAL VALUE OF KL/r : 95.56 ALLOWABLE KL/r : 400.00 RESULT : PASS CALCULATION OF ALLOWABLE STRESS --------------------------------- CRITICAL CONDITION : TENSION ALLOWABLE AXIAL TENSILE STRESS : 249.94 MPA CHECK AGAINST PERMISSIBLE STRESS -------------------------------- LOAD NO. : 3 DESIGN AXIAL FORCE : 112909.27 N ACTUAL AXIAL TENSILE STRESS : 112909.27 / ( 2903.0*0.801 ) : 48.53 MPA RESULT : PASS BOLTING ------- BOLT DIA : 16 MM SHEARING CAP : 43.83 KN BEARING CAP : 55.81 KN BOLT CAP : 43.83 KN NO. OF BOLTS REQD. : 3 ********** END OF TABULATED RESULT OF DESIGN ***********

Page 468: International Design Codes

Steel Design Per IS802 Section 8C 8-92

Page 469: International Design Codes

8-93

Design Per Indian Cold Formed Steel Code

Section 8D

8D.1 General

Provisions of IS:801-1975, including revisions dated May, 1988, have been implemented. The program allows design of single (non-composite) members in tension, compression, bending, shear, as well as their combinations. Cold work of forming strengthening effects have been included as an option.

8D.2 Cross-Sectional Properties

The user specifies the geometry of the cross-section by selecting one of the section shape designations from the Gross Section Property Tables from IS:811-1987(Specification for cold formed light gauge structural steel sections). The Tables are currently available for the following shapes:

• Channel with Lips • Channel without Lips • Angle without Lips • Z with Lips • Hat

Shape selection may be done using the member property pages of the graphical user interface (GUI) or by specifying the section designation symbol in the input file.

Page 470: International Design Codes

Design Per Indian Cold Formed Steel Code Section 8D 8-94

The properties listed in the tables are gross section properties. STAAD.Pro uses unreduced section properties in the structure analysis stage. Both unreduced and effective section properties are used in the design stage, as applicable.

8D.3 Design Procedure

The following two design modes are available:

1. Code Checking

The program compares the resistance of members with the applied load effects, in accordance with IS:801-1975. Code checking is carried out for locations specified by the user via the SECTION command or the BEAM parameter. The results are presented in a form of a PASS/FAIL identifier and a RATIO of load effect to resistance for each member checked. The user may choose the degree of detail in the output data by setting the TRACK parameter.

2. Member Selection

The user may request that the program search the cold formed steel shapes database (IS standard sections) for alternative members that pass the code check and meet the least weight criterion. In addition, a minimum and/or maximum acceptable depth of the member may be specified. The program will then evaluate all database sections of the type initially specified (i.e., channel, angle, etc.) and, if a suitable replacement is found, presents design results for that section. If no section satisfying the depth restrictions or lighter than the initial one can be found, the program leaves the member unchanged, regardless of whether it passes the code check or not. The program calculates effective section properties in accordance with Clause 5.2.1.1. Cross-sectional properties and overall slenderness of members are checked for compliance with

Page 471: International Design Codes

Section 8D 8-95

• Clause 6.6.3, Maximum Effective Slenderness Ratio for members in Compression

• Clause 5.2.3, Maximum Flat Width Ratios for Elements in Compression

• Clause 5.2.4, Maximum Section Depths. The program will check member strength in accordance with Clause 6 of the Standard as follows: Members in tension

Resistance is calculated in accordance with Clauses 6.1 Members in bending and shear Resistance calculations are based on Clauses:

a) 6.4.1 Shear stress in webs,

b) 6.4.2 Bending stress in webs

c) 6.4.3 Combined Bending and Shear in Webs. Members in compression Resistance calculations are based on Clauses:

a) 6.2 Compression on flat unstiffened element,

b) 6.6.1.1 Shapes not subject to torsional-flexural buckling,

c) 6.6.1.2 Singly-symmetric sections and nonsymmetrical shapes of open cross section or intermittently fastened singly-symmetrical components of built-up shapes having Q = 1.0 which may be subject to torsional-flexural buckling,

Page 472: International Design Codes

Design Per Indian Cold Formed Steel Code Section 8D 8-96

d) 6.6.1.3 Singly-symmetric sections and nonsymmetrical

shapes or intermittently fastened singly-symmetrical components of built-up shapes having Q < 1.0 which may be subject to torsional-flexural buckling,

e) 6.8 Cylindrical Tubular Sections. Members in compression and bending Resistance calculations are based on Clauses:

a) All clauses for members in compression

&

b) 6.3 Laterally Unsupported Members,

c) 6.7.1 Doubly-symmetric shapes or Shapes not subjected to torsional or torsional-flexural buckling

d) 6.7.2. Singly-symmetric shapes or Intermittently fastened

singly-symmetric components of built-up shapes having Q=1.0 which may be subjected to torsional-flexural buckling

e) 6.7.3. Singly-symmetric shapes or Intermittently fastened

singly-symmetric components of built-up shapes having Q<1.0 which may be subjected to torsional-flexural buckling.

Input for the coefficients of uniform bending must be provided by the user.

Page 473: International Design Codes

Section 8D 8-97

The following table contains the input parameters for specifying values of design variables and selection of design options.

COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value

Description

BEAM 1.0 When this parameter is set to 1.0 (default), the adequacy of the member is determined by checking a total of 13 equally spaced locations along the length of the member. If the BEAM value is 0.0, the 13 location check is not conducted, and instead, checking is done only at the locations specified by the SECTION command (See STAAD manual for details. For TRUSS members only start and end locations are designed.

CMZ 1.0 Coefficient of equivalent uniform bending ωz. See IS:801-1975, 6.7. Used for Combined axial load and bending design. Values range from 0.4 to 1.0.

CMY 0.85 Coefficient of equivalent uniform bending ωy. See IS:801-1975, 6.7. Used for Combined axial load and bending design. Values range from 0.4 to 1.0.

CWY 0.85 Specifies whether the cold work of forming strengthening effect should be included in resistance computation. See IS:801-1975, 6.1.1

Values: 0 – effect should not be included

1 – effect should be included

FLX 1 Specifies whether torsional-flexural buckling restraint is provided or is not necessary for the member. See IS:801-1975, 6.6.1

Values:

0 – Section not subject to torsional flexural buckling 1 – Section subject to torsional flexural buckling

FU 450 MPa (4588.72 kg/cm2)

Ultimate tensile strength of steel in current units.

Page 474: International Design Codes

Design Per Indian Cold Formed Steel Code Section 8D 8-98

COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value

Description

FYLD 353.04 MPa

(3600.0 kg/cm2)

Yield strength of steel in current units.

KX 1.0 Effective length factor for torsional buckling. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the capacity in axial compression.

KY 1.0 Effective length factor for overall buckling about the local Y-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

KZ 1.0 Effective length factor for overall buckling in the local Z-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a member completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

LX Member length

Unbraced length for twisting. It is input in the current units of length. Values can range from 0.01 (for a member completely prevented from torsional buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the capacity in axial compression.

LY Member length

Effective length for overall buckling in the local Y-axis. It is input in the current units of length. Values can range from 0.01 (for a member completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

LZ Member length

Effective length for overall buckling in the local Z-axis. It is input in the current units of length. Values can range from

Page 475: International Design Codes

Section 8D 8-99

COLD FORMED STEEL DESIGN PARAMETERS

Parameter Name

Default Value

Description

0.01 (for a member completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the capacity in axial compression.

MAIN 0 0 – Check slenderness ratio

0 – Do not check slenderness ratio

NSF 1.0 Net section factor for tension members DMAX

2540.0 cm. Maximum allowable depth. It is input in the current units of

length.

RATIO 1.0 Permissible ratio of actual to allowable stresses

TRACK 0 This parameter is used to control the level of detail in which the design output is reported in the output file. The allowable values are: 0 - Prints only the member number, section name, ratio, and

PASS/FAIL status. 1 - Prints the design summary in addition to that printed by

TRACK 1 2 - Prints member and material properties in addition to that

printed by TRACK 2. TSA 1 Specifies whether webs of flexural members are adequately

stiffened to satisfy the requirements of IS:801-1975, 5.2.4.

Values:

0 – Do not comply with 5.2.4

1 – Comply with 5.2.4

Page 476: International Design Codes

Design Per Indian Cold Formed Steel Code Section 8D 8-100

Page 477: International Design Codes

Section 9 Japanese Codes

Page 478: International Design Codes

;alksdf;lkajf

Page 479: International Design Codes

9-1

Concrete Design Per AIJ

Section 9A

9A.1 Design Operations

STAAD has the capabilities of performing concrete design based on the AIJ standard for structural calculation of Reinforced Concrete Structures (1985 edition). Design for a member involves calculation of the amount of reinforcement required for the member. Calculations are based on the user specified properties and the member forces obtained from the analysis. In addition, the details regarding placement of the reinforcement on the cross section are also reported in the output.

9A.2 Section Types for Concrete Design

The following types of cross sections for concrete members can be designed. For Beams Prismatic (Rectangular & Square) For Columns Prismatic (Rectangular, Square and Circular)

9A.3 Member Dimensions

Concrete members which will be designed by the program must have certain section properties input under the MEMBER PROPERTY command. The following example shows the required input:

Page 480: International Design Codes

Concrete Design Per AIJ Section 9A 9-2

UNIT MM MEMBER PROPERTY 1 3 TO 7 9 PRISM YD 450. ZD 250. 11 13 PR YD 350.

In the above input, the first set of members are rectangular (450 mm depth and 250mm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with 350mm diameter. It is absolutely imperative that the user not provide the cross section area (AX) as an input.

9A.4 Slenderness Effects and Analysis Consideration

Slenderness effects are extremely important in designing compression members. Slenderness effects result in additional forces being exerted on the column over and above those obtained from the elastic analysis. There are two options by which the slenderness effects can be accommodated. The first option is to compute the secondary moments through an exact analysis. Secondary moments are caused by the interaction of the axial loads and the relative end displacements of a member. The axial loads and joint displacements are first determined from an elastic stiffness analysis and the secondary moments are then evaluated. The second option is to approximately magnify the moments from the elastic analysis and design the column for the magnified moment. It is assumed that the magnified moment is equivalent to the total moment comprised of the sum of primary and secondary moments. STAAD provides facilities to design according to both of the above methods. To utilize the first method, the command PDELTA ANALYSIS must be used instead of PERFORM ANALYSIS in the

Page 481: International Design Codes

Section 9A 9-3

input file. The user must note that to take advantage of this analysis, all the combinations of loading must be provided as primary load cases and not as load combinations. This is due to the fact that load combinations are just algebraic combinations of forces and moments, whereas a primary load case is revised during the P-delta analysis based on the deflections. Also, note that the proper factored loads (like 1.5 for dead load etc.) should be provided by the user. STAAD does not factor the loads automatically. The second method mentioned above is utilized by providing the magnification factor as a concrete design parameter (See the parameter MMAG in Table 9A.1). The column is designed for the axial load and total of primary and secondary biaxial moments if the first method is used and for the axial load and magnified biaxial moments if the second method is used.

9A.5 Beam Design

Beams are designed for flexure, shear and torsion. Program considers 12 equally spaced sections of the beam member. However this number can be redefined by NSECTION parameter. All these sections are designed for flexure, shear and torsion for all the load cases and print out the design results for most critical load case. Design for Flexure

Reinforcement for positive and negative moments are calculated on the basis of section properties provided by the user. Program first try to design the section for γ=0 and pt = balanced reinforcement ratio. If allowable moment is lower than the actual moment program increases γ value for same pt and checks the satisfactory conditions. If conditions are not satisfied this procedure continues until γ reaches to 1.0 and then pt value is increased keeping γ = 1.0. This procedure continues until pt reaches to its maximum value( 2 % ). But if the allowable moment for pt = maximum value and γ = 1.0 is lower than the actual moment the program gives message that the section fails. This program automatically calculates the Bar size and no. of bars needed to design the section. It arranges the bar in layers as per

Page 482: International Design Codes

Concrete Design Per AIJ Section 9A 9-4

the requirements and recalculate the effective depth and redesign the sections for this effective depth. Please note,

• Beams are designed for MZ only. The moment MY is not considered in flexure design

• MMAG parameter can be used to increase design moment

• 1.4 cm. is added to the clear cover to take stirrup size into consideration for flexure design.

• STAAD beam design procedure is based on the local practice and considering the fact that Japan is a high seismic zone area.

Design for Shear

Shear design of beam is done for Qy value. The update effective depth is used for allowable shear stress calculation. Allowable shear stress of concrete is automatically calculated from design load type (permanent or temporary) and given density of concrete. Program calculates required Bar size and spacing of stirrups. Pw is calculated for design Bar size and spacing and all the necessary checking is done. For seismic load it is needed to increase shear force 1.5 times the actual value and this can be done utilizing SMAG parameter. Please note, • SMAG parameter can be used if its needed to increase the

Design Shear Force without changing Design Moment.

• Stirrups are always assumed to be 2-legged

• Governing density to determine Light weight or Normal Weight Concrete is 2.3 kg/sq. cm

Page 483: International Design Codes

Section 9A 9-5

Example of Input Data for Beam Design UNIT KG CM START CONCRETE DESIGN CODE JAPAN FYMAIN SRR295 ALL FYSEC SRR295 ALL FC 350 ALL CLEAR 2.5 MEM 2 TO 6 TRACK 1.0 MEMB 2 TO 9 DESIGN BEAM 2 TO 9 END CONCRETE DESIGN

Design for Torsion

Torsion design for beam is optional. If TORSION parameter value is 1.0, program design that beam for torsion. Program first checks whether extra reinforcement is needed for torsion or not. If additional reinforcement is needed, this additional pt is added to flexure pt and additional Pw is added to shear design Pw.

9A.6 Column Design

Columns are designed for axial force, MZ moment, MY moment and shear force. Both the ends of the members are designed for all the load cases and the loading which produces largest amount of reinforcement is called as critical load. If Track 0 or Track 1 is used, design results will be printed for critical load only. But if Track 2 is used user can get details design results of that member. Pt needed for minimum axial force, maximum axial force, maximum MZ, maximum MY among all the load cases for both the ends will be printed. If MMAG parameter is used, the column moments will be multiplied by that value. If SMAG parameter is used, column shear force will be multiplied by that value. Column design is done for Rectangular, Square and Circular sections. For rectangular and square sections Pt value is calculated

Page 484: International Design Codes

Concrete Design Per AIJ Section 9A 9-6

separately for MZ and MY, while for circular sections Pg value is calculated for MZ and MY separately. Column design for biaxial moments is optional. If BIAXIAL parameter value 1.0, program will design the column for biaxial moments. Otherwise column design is always uniaxial type. Steps involved : 1) Depending on the axial force zone is determined for Pt = 0.0 . 2) If the column is in "zone A", design is performed by

increasing Pt and checking allowable load for that known Pt and known actual eccentricity of the column.

3) If the column is in "zone B" or in "zone C", xn is calculated

for given P and Pt and checking is done for allowable moment, if allowable moment is less than the actual moment, program increases Pt and this procedure continues until the column design conditions are satisfied or the column fails as the required Pt is higher than Pt maximum value.

4) If the column is in tension, design is done by considering

allowable tensile stress of steel only. 5) If biaxial design is requested program solve the following

interaction equation

0.1Mzcap

MzMycap

My≤⎟⎟

⎠⎝⎠⎝ where, α = 1.0+1.66666666 × (ratio-0.2), ratio = P/Pcap &

.0 ≤ α ≤

⎞⎜⎜⎛

+⎟⎟⎞⎛

αα

2.0, Mycap, Mzcap & Pcap represents section

6)

⎜⎜

1capacity

If the interaction equation is not satisfied program increases Ptand calculates Pcap, Mycap and Mzcap and solve the interaction equation again and this process continues until the

Page 485: International Design Codes

Section 9A 9-7

eqn. is satisfied or the column fails as Pt exceeds its maximum

7) uested program assumes that

interaction equation is satisfied ( if uniaxial design is

) If the interaction equation is satisfied program determines bar

size and calculates no. of bars and details output is written.

limit.

If biaxial design is not req

performed successfully ).

8

Example of Input Data for Column Design UNIT KGS CMS START CONCRETE DESIGN CODE JAPAN FYMAIN SRR295 ALL FC 210 ALL CLEAR 2.5 MEMB 2 TO 6 DESIGN COLUMN 2 TO 6 END CONCRETE DESIGN

9A.7 Slab/Wall Design

inite d. The command specifications are in

ccordance with Chapter 2 and Chapter 6 of the Technical

oted as longitudinal reinforcement

To design a slab or a wall, it must first be modelled using felements and analyseaReference Manual. Elements are designed for the moments Mx and My. These moments are obtained from the element force output (see Chapter 2 of the Technical Reference Manual). The reinforcement required to resist the Mx moment is denand the reinforcement required to resist the My moment is denoted as transverse reinforcement.

Page 486: International Design Codes

Concrete Design Per AIJ Section 9A 9-8

The longitudinal bar is the layer closest to the exterior face of the e following paslab or wall. Th rameters are those applicable to slab

ll design

1. FYMAIN

3. CLEAR e outer surface of the element to the edge of the bar. This is considered the same on

mum required size of longitudinal/transverse reinforcing bar

The other parameters shown in Table 9A.1 are not applicable to slab or wall design.

and wa :

Yield stress for reinforcing steel - transverse and longitudinal.

2. FC Concrete grade Distance from th

both top and bottom surfaces of the element. 4. MINMAIN Mini

LONG.

TRANS.

X

Y

Z

M

MM

M x

y

x

y

9A.8 Desi

e changed to suit the particular design being performed. Table 9A.1 contains a complete list of the available parameters and their default values. It is necessary to declare length and force units as centimeters and Kilograms before performing the concrete design.

gn Parameters

The program contains a number of parameters which are needed to perform the design. Default parameter values have been selectedsuch that they are frequently used numbers for conventional design requirements. These values may b

Page 487: International Design Codes

Section 9A 9-9

Table 9A.1 Japanese Concrete Design Parameters

Parameter Name

Default Value Description

FYMAIN 2200 Kg/cm2 Yield Stress for main reinforcing steel, but user should input this value as steel grade, like SD345, SD295A, etc. program automatically calculates yield stress value depending on design load type (permanent or temporary).

FYSEC 2000 Kg/cm2 Same as FYMAIN except this is for secondary steel.

FC 210 Kg/cm2 Compressive Strength of Concrete.

CL 3.0 cm Clear cover for Beam.

CLS 4.0 cm Clear side cover for Column.

MINMAIN 10 mm Minimum main reinforcement bar size.

MINSEC 10 mm Minimum secondary reinforcement bar size.

MAXMAIN 41.0 cm Maximum main reinforcement bar size

MAXSEC 41.0 cm Maximum secondary reinforcement bar size.

SFACE 0.0 Face of support location at start of beam.

EFACE 0.0 Face of support location at end of beam. (Note: Both SFACE & EFACE are input as positive numbers).

REINF 0.0 Tied Column. A value of 1.0 will mean spiral.

MMAG 1.0 Design moment magnification factor

SMAG 1.0 Design shear magnification factor

LONG 0.0 Value to define design load type 0 = Permanent Loading 1 = Temporary Loading

BIAXIAL 0.0 Value to define biaxial or uniaxial design type for Column 0 = uniaxial design only 1 = design for biaxial moments

TORSION 0.0 Value to request for torsion design for beam 0 = torsion design not needed 1 = torsion design needed

Page 488: International Design Codes

Concrete Design Per AIJ Section 9A 9-10

Table 9A.1 Japanese Concrete Design Parameters

Parameter Name

Default Value Description

WIDTH ZD Width of concrete member. This value defaults to ZD as provided under MEMBER PROPERTIES.

DEPTH YD Depth of concrete member. This value defaults to YD as provided under MEMBER PROPERTIES.

NSECTION 12 Number of equally-spaced sections to be considered in finding critical moments for beam design.

TRACK 0.0 BEAM DESIGN: 0.0 = Critical section design results. 1.0 = Five section design results & design

forces. 2.0 = 12 section design results & design forces. COLUMN DESIGN: 1.0 = Detail design results for critical load case

only.

2.0 = Design results for minimum P, maximum P, maximum MZ and maximum MY among all load cases for both ends.

Page 489: International Design Codes

9-11

Steel Design Per AIJ

Section 9B

9B.1 General

This section presents some general statements regarding the implementation of the “Architectural Institute of Japan” (AIJ) specifications for structural steel design (1986 edition) in STAAD. The design philosophy and procedural logistics are based on the principles of elastic analysis and allowable stress design. Facilities are available for member selection as well as code checking. Two major failure modes are recognized: failure by overstressing and failure by stability considerations. The following sections describe the salient features of the design approach. Members are proportioned to resist the design loads without exceedance of the allowable stresses or capacities and the most economical section is selected on the basis of the least weight criteria. The code checking part of the program also checks the slenderness requirements and the stability criteria. Users are recommended to adopt the following steps in performing the steel design: • Specify the geometry and loads and perform the analysis. • Specify the design parameter values if different from the

default values. • Specify whether to perform code checking or member

selection.

Page 490: International Design Codes

Steel Design Per AIJ Section 9B 9-12

9B.2 Analysis Methodology

Elastic analysis method is used to obtain the forces and moments for design. Analysis is done for the primary and combination loading conditions provided by the user. The user is allowed complete flexibility in providing loading specifications and in using appropriate load factors to create necessary loading situations. Depending upon the analysis requirements, regular stiffness analysis or P-Delta analysis may be specified. Dynamic analysis may also be performed and the results combined with static analysis results.

9B.3 Member Property Specifications

For specification of member properties of standard Japanese steel shapes, the steel section library available in STAAD may be used. The next section describes the syntax of commands used to assign properties from the built-in steel table. Members properties may also be specified using the User Table facility. For more information on these facilities, refer to the STAAD Technical Reference Manual.

9B.4 Built-in Japanese Steel Section Library

The following information is provided for use when the built-in steel tables are to be referenced for member property specification. These properties are stored in a database file. If called for, these properties are also used for member design. Since the shear areas are built into these tables, shear deformation is always considered for these members during the analysis. An example of member property specification in an input file is provided at the end of this section.

Page 491: International Design Codes

Section 9B 9-13

A complete listing of the sections available in the built-in steel section library may be obtained using the tools of the graphical user interface. Following are the descriptions of different types of sections. I shapes I shapes are specified in the following way:

I 250 X 125 X 10

Note : While specifying the web thickness, the portion after the decimal point should be excluded.

Example : 1 TO 9 TA ST I300X150X11 12 TO 15 TA ST I350X150X9

H shapes H shapes are specified as follows:

Web thickness (mm) Section-type (I)

Nominal height (mm)

H 600 X 200 X 11

Nominal width of flange (mm)

Section-type (H)

Nominal height (mm)

Web thickness (mm)

Nominal width of flange (mm)

Note : While specifying the web thickness, the portion after the decimal point should be excluded.

Example: 1 TO 8 TA ST H200X100X4 13 TO 17 TA ST H350X350X12

Page 492: International Design Codes

Steel Design Per AIJ Section 9B 9-14

T shapes T shapes are specified as follows: T

250 X 16

Section-type (T)

Nom

Note : While specifying the web thickness, the portion after the decimal point should be excluded

Example: 20 TO 25 TA ST T250X19

Channels Channel sections are specified as follows.

inal width of flange (mm)

C 300 X 90 X 10

Flange thickness (mm)

Web thickness (mm)

Nominal width of flange (mm)

Section-type (C)

Nominal height (mm)

Example: 25 TO 34 TA ST C125X65X6 46 TO 49 TA ST C200X90X8

Double Channels Back to back double channels, with or without a spacing in between them, are available. The letter D in front of the section name is used to specify a double channel.

17 TO 27 TA D C300X90X10 45 TO 76 TA D C250X90X11 SP 2.0

In the above commands, members 17 to 27 are a back to back double channel C300X90X10 with no spacing in between.

Page 493: International Design Codes

Section 9B 9-15

Members 45 to 76 are a double channel C250X90X11 with a spacing of 2 length units. Angles Two types of specification may be used to describe an angle. The standard angle specification is as follows.

L 125 X 90 X 10

Section-type (L)

Length of longer side (mm)

Thickness (mm)

Length of shorter side (mm)

The letter L (signifying that the section is an angle) is followed by the length of the legs and then the thickness of the leg, all in millimetres. The word ST signifies that the section is a STandard angle meaning that the major principal axis coincides with the local YY axis specified in Chapter 1 of Section 1.5.2 of the User's Manual.

Example: 1 4 TA ST L150X90X9

If the minor principal axis coincides with the local YY axis specified in Chapter 2 of the User's Manual, the word RA (Reverse Angle) should be used instead of ST as shown below.

7 TO 23 TA RA L90X75X9

Double angles Short leg back to back and long leg back to back double angles may be specified by using the words SD or LD in front of the angle size. In the case of an equal angle, either SD or LD will serve the purpose. The spacing between the angles may be specified by using the word SP after the angle size followed by the value of the spacing.

Page 494: International Design Codes

Steel Design Per AIJ Section 9B 9-16

8 TO 25 TA SD L100X65X7 SP 2.0 36 TO 45 TA LD L300X90X11 SP 3.0

The first example indicates a short legs back to back double angle comprised of 100X65X7 angles separated by 2 length units. The latter is a long legs back to back double angle comprised of 300X90X11 angles separated by 3 length units. Tubes Tube names are input by their dimensions. For example,

6 TA ST TUBE DT 8.0 WT 6.0 TH 0.5

is a tube that has a height of 8 length units, width of 6 length units and a wall thickness of 0.5 length units. Only code checking, no member selection can be performed on TUBE sections. Pipes (Circular Hollow sections) Circular hollow sections may be provided by specifying the word PIPE followed by the outside and inside diameters of the section. For example,

1 TO 9 TA ST PIPE OD 25.0 ID 20.0

specifies a pipe with outside diameter of 25 length units and an inside diameter of 20 length units. Only code checking, no member selection, can be performed on PIPE sections.

Page 495: International Design Codes

Section 9B 9-17

Sample Input file containing Japanese shapes STAAD SPACE UNIT KIP FEET JOINT COORD 1 0 0 0 12 11 0 0 MEMB INCIDENCE 1 1 2 11 UNIT INCH MEMBER PROPERTY JAPANESE * H-SHAPE 1 TA ST H200X100X4 * I SHAPE 2 TA ST I250X125X10 * T SHAPE 3 TA ST T200X19 * CHANNEL 4 TA ST C125X65X6 * DOUBLE CHANNEL 5 TA D C200X90X8 * REGULAR ANGLE 6 TA ST L100X75X7 * REVERSE ANGLE 7 TA RA L90X75X9 * DOUBLE ANGLE - LONG LEG BACK TO BACK 8 TA LD L125X75X7 SP 2.0 * DOUBLE ANGLE - SHORT LEG BACK TO BACK 9 TA SD L300X90X11 SP 1.5 * TUBE 10 TA ST TUBE DT 3.0 WT 2.5 TH 0.25 * PIPE 11 TA ST PIPE OD 3.0 ID 2.5 PRINT MEMBER PROPERTIES FINISH

Page 496: International Design Codes

Steel Design Per AIJ Section 9B 9-18

9B.5 Member Capacities

As mentioned before, member design and code checking in STAAD are based upon the allowable stress design method. It is a method for proportioning structural members using design loads and forces, allowable stresses, and design limitations for the appropriate material under service conditions. The basic measure of member capacities are the allowable stresses on the member under various conditions of applied loading such as allowable tensile stress, allowable compressive stress etc. These depend on several factors such as cross sectional properties, slenderness factors, unsupported width to thickness ratios and so on. Explained here is the procedure adopted in STAAD for calculating such capacities. Design Capabilities

All types of available shapes like H-Shape, I-Shape, L-Shapes, CHANNEL, PIPE, TUBE, Prismatic section etc. can be used as member property and STAAD will automatically adopt the design procedure for that particular shape if Steel Design is requested. STEEL TABLE available within STAAD or UPTABLE facility can be used for member property. Methodology

For steel design, STAAD compares the actual stresses with the allowable stresses as required by AIJ specifications. The design procedure consist of following three steps. 1) Calculation of sectional properties

Program extract sectional properties like sectional area ( A ), Moment of Inertia about Y axis and Z axis ( Iyy, Izz) from in-built Japanese Steel Table and calculates Zz, Zy, iy, iz using appropriate formula. For calculation of i ( radius of gyration needed for bending ), program calculates moment of inertia ( Ii )and sectional area ( Ai ) for 1/6th section and then uses following formula:

Page 497: International Design Codes

Section 9B 9-19

AiIii =

n of i is applicable for I shape, H shape and Channel sections.

2) alculates actual and allowable stresses by following

ethods:

i) ( A × NSF ),

ctual compressive stress ( FC ) = Force / A

ble tensile stress ( ft ) = F / 1.5 (For Permanent

F ( For Temporary Case )

Allowable compressive stress

Please note, that the above mentioned procedure for calculatio

Calculation of actual and allowable stresses Program cm

Axial Stress : Actual tensile stresses ( FT ) = Force / NSF = Net Section Factor for tension A AllowaCase) =

( ){ } ∆≤λν∆λ−= when /F x / x4.1 )fc( 2

( ) ∆>λ∆λ= when / /F x 77.2 2 = fc × 1 ary Case ) .5 (For Tempor

)xF6/(.E2π=∆ where, ∆ =F) , ν =3 / 2 + 2 / 3 × (λ / ∆)2

ii)

ss for Mz for compression

z for tension

Bending Stress : Actual bending stress for My for compression ( Fbcy) = My / Zcy

ctual bending streA( Fbcz) = Mz / Zcz Actual bending stress for My for tension ( Fbty) = My / Zcy

ctual bending stress for MA( Fbtz) = Mz / Zcz

Page 498: International Design Codes

Steel Design Per AIJ Section 9B 9-20

where, Zcy , Zcz are section modulus for compression and ty, Ztz are section modulus for tension

ending stress for My

i )2 / (C λ2)}ft max

porary case, fbcz = 1.5 × (fbcz for Permanent

here, C = 1.75 -1.05(M2/M1)+0.3(M2/M1)2

llowable bending stress for Mz ( fbtz) = fbcz

iii) ses are calculated by following formula :

w = web shear area = product of depth and web

, Aff = flange shear area = 2/3 times total flange

llowable shear stress ( fs ) = Fs / 1.5 , Fs = F /

Z Allowable b( fbcy) = ft Allowable bending stress for Mz ( fbcz) = { 1-.4 × (lb /= 900/ ( lb × h / Af ) For TemCase) w Allowable bending stress for My ( fbty) = ft A Shear Stress Actual shear stresqy = Qy / Aww, Where, Awthickness qz = Qz / Aff , Whereareas

3 A

3) efault 1.0 ) is used for

hecking design requirements

xceeds RATIO , program gives the message that the section fails.

tio = FC / fc iii)

bending ratio = FC/fc+Fbz/fbz+Fby/fby

Checking design requirements : User provided RATIO value ( dc

The following conditions are checked to meet the AIJ specifications. For all the conditions calculated value should not be more than the value of RATIO. If for any condition value e Conditions: i) Axial tensile stress ratio = FT / ft ii) Axial compressive stress ra

Combined compression &

Page 499: International Design Codes

Section 9B 9-21

iv) Combined compression & bending ratio = (Fbtz+Fbty-FC) / ft

v) Combined tension & bending ratio = FT/ft +Fbz/fbz+Fby/fby vi) Combined tension & bending ratio = (Fbcz+Fbcy-FT) / fbcz vii) Shear stress ratio for qy = qy / fs viii) Shear stress ratio for qz = qz / fs New Output Format ( TRACK -- 3 )

One new output format has been introduced which provides details step by step information of Steel Design for guiding load case only. If Section command is used before Parameter command this output will provide details information for all the sections specified by Section Command. Please note, that this output format is available only when Beam parameter value is 0 and Track parameter value is 3. If section command is not used design information will be printed for two ends only. If Member Truss option is used no Shear Design information will be printed.

Example: SECTION 0.0 0.25 0.5 0.75 1.0 ALL PARAMETER CODE JAPAN BEAM 0.0 ALL TMP 0.0 MEMB 1 to 4 TMP 1.0 MEMB 5 to 8 TRACK 3 ALL CHECK CODE ALL FINISH

Allowable stress for Axial Tension

Allowable axial stress in tension is calculated per section 5.1 (1) of the AIJ code. In members with axial tension, the tensile load must not exceed the tension capacity of the member. The tension capacity of the member is calculated on the basis of the member

Page 500: International Design Codes

Steel Design Per AIJ Section 9B 9-22

area. STAAD calculates the tension capacity of a given member based on a user supplied net section factor (NSF-a default value of 1.0 is present but may be altered by changing the input value, see Table 8B.1) and proceeds with member selection or code checking. Allowable stress for Axial Compression

The allowable stress for members in compression is determined according to the procedure of section 5.1 (3). Compressive resistance is a function of the slenderness of the cross-section (Kl/r ratio) and the user may control the slenderness value by modifying parameters such as KY, LY, KZ and LZ. In the absence of user provided values for effective length, the actual member length will be used. The slenderness ratios are checked against the permissible values specified in Chapter 11 of the AIJ code. Allowable stress for Bending

The permissible bending compressive and tensile stresses are dependent on such factors as length of outstanding legs, thickness of flanges, unsupported length of the compression flange (UNL, defaults to member length) etc. The allowable stresses in bending (compressive and tensile) are calculated as per the criteria of Clause 5.1 (4) of the code. Allowable stress for Shear

Shear capacities are a function of web depth, web thickness etc. The allowable stresses in shear are computed according to Clause 5.1 (2) of the code.

9B.6 Combined Loading

For members experiencing combined loading (axial force, bending and shear), applicable interaction formulas are checked at different locations of the member for all modelled loading situations. Members subjected to axial tension and bending are checked using the criteria of clause 6.2. For members with axial compression and bending, the criteria of clause 6.1 is used.

Page 501: International Design Codes

Section 9B 9-23

9B.7 Design Parameters

The user is allowed complete control over the design process through the use of parameters mentioned in Table 9B.1 of this chapter. These parameters communicate design decisions from the engineer to the program. The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements of the situation, some or all of these parameter values may have to be changed to exactly model the physical structure.

Table 9B.1 - Japanese Steel Design Parameters

Parameter Name

Default Value Description

KY 1.0 K value in local y-axis. Usually, this is the minor axis.

KZ 1.0 K value in local z-axis. Usually, this is the major axis.

LY Member Length

Length in local y-axis to calculate slenderness ratio.

LZ Member Length

Same as above except in z-axis

FYLD 235 MPA Yield strength of steel in Megapascal.

NSF 1.0 Net section factor for tension members.

UNL Member Length

Unsupported length for calculating allowable bending stress.

UNF 1.0 Same as above provided as a fraction of actual member length.

SSY 0.0 0.0 = Sidesway in local y-axis. 1.0 = No sidesway

SSZ 0.0 Same as above except in local z-axis.

MAIN 0.0 0.0 = check for slenderness 1.0 = suppress slenderness check

Page 502: International Design Codes

Steel Design Per AIJ Section 9B 9-24

Table 9B.1 - Japanese Steel Design Parameters

Parameter Name

Default Value Description

TRACK 0.0 0.0 = Suppress critical member stresses 1.0 = Print all critical member stresses 2.0 = Print expanded output

DMAX 100 cm Maximum allowable depth for member.

DMIN 0.0 cm Minimum allowable depth for member.

TMP 0 (Permanent

Load)

0 = Permanent Loading 1 = Temporary Loading

RATIO 1.0 Permissible ratio of the actual to allowable stresses.

BEAM 0.0 0.0 = design only for end moments or those at locations specified by the SECTION command.

1.0 = calculate moments at twelfth points along the beam, and use the maximum Mz location for design.

DFF None (Mandatory for

deflection check)

"Deflection Length" / Maxm. allowable local deflection

DJ1 Start Joint of member

Joint No. denoting starting point for calculation of "Deflection Length" (See Note 1)

DJ2 End Joint of member

Joint No. denoting end point for calculation of "Deflection Length" (See Note 1)

NOTE: 1) "Deflection Length" is defined as the length that is used for

calculation of local deflections within a member. It may be noted that for most cases the "Deflection Length" will be equal to the length of the member. However, in some situations, the "Deflection Length" may be different. For example, refer to the figure below where a beam has been modeled using four joints and three members. Note that the "Deflection Length" for all three members will be equal to the total length of the beam in this case. The parameters DJ1 and DJ2 should be used to model this situation. Also the straight line joining DJ1 and

Page 503: International Design Codes

Section 9B 9-25

DJ2 is used as the reference line from which local deflections are measured. Thus, for all three members here, DJ1 should be "1" and DJ2 should be "4".

D = Maximum local deflection for members1, 2 and 3.

D

1

2 3

4

1

2 3

EXAMPLE : PARAMETERS DFF 300. ALL DJ1 1 ALL DJ2 4 ALL

2) If DJ1 and DJ2 are not used, "Deflection Length" will default

to the member length and local deflections will be measured from original member line.

3) The above parameters may be used in conjunction with other available parameters for steel design.

9B.8 Code Checking

The purpose of code checking is to check whether the provided section properties of the members are adequate to carry the forces transmitted to it by the loads on the structure. The adequacy is checked per the AIJ requirements. Code checking is done using forces and moments at specified sections of the members. If the BEAM parameter for a member is set to 1, moments are calculated at every twelfth point along the beam, and the maximum moment about the major axis is used. When no sections are specified and the BEAM parameter is set to zero (default), design will be based on the forces at the start and end joints of the member. The code checking output labels the members as PASSed or FAILed. In addition, the critical condition, governing load case, location (distance from start joint) and magnitudes of the governing forces and moments are also printed.

Page 504: International Design Codes

Steel Design Per AIJ Section 9B 9-26

9B.9 Member Selection

The member selection process basically involves determination of the least weight member that PASSes the code checking procedure based on the forces and moments obtained from the most recent analysis. The section selected will be of the same type as that specified initially. For example, a member specified initially as a channel will have a channel selected for it. Selection of members whose properties are originally provided from a user table will be limited to sections in the user table. Member selection cannot be performed on TUBES, PIPES or members listed as PRISMATIC.

Sample Input data for Steel Design UNIT METER PARAMETER CODE JAPAN NSF 0.85 ALL UNL 10.0 MEMBER 7 KY 1.2 MEMBER 3 4 RATIO 0.9 ALL TRACK 1.0 ALL CHECK CODE ALL SELECT ALL

Page 505: International Design Codes

Section 10 Mexican Codes

Page 506: International Design Codes
Page 507: International Design Codes

10-1

Concrete Design Per MEX NTC 1987

Section 10A

10A.1 Design Operations

STAAD has the capabilities for performing concrete design. It will calculate the reinforcement needed for the specified concrete section. All the concrete design calculations are based on the current: Complementary Technical Standards for the Design and Construction of Concrete Structures – Nov. 1987. (Normas Técnicas Complementarias para Diseño y construcción de Estructuras de Concreto) of the Mexican Construction Code for the Federal District –Aug. 1993 (Reglamento de Construcciones para el Distrito Federal).

10A.2 Section Types for Concrete Design

The following types of cross sections can be defined for concrete design. For Columns Prismatic (Rectangular, Square and Circular) For Beams Prismatic (Rectangular & Square), Trapezoidal

and T-shapes For Slabs Finite element with a specified thickness

Page 508: International Design Codes

Concrete Design Per Mexican Code Section 10A 10-2

10A.3 Member Dimensions

Concrete members which will be designed by the program must have certain section properties input under the MEMBER PROPERTY command. The following example shows the required input: UNIT CM MEMBER PROPERTY 13 TO 79 PRISM YD 40. ZD 20. IZ 53333 IY 13333 11 13 PR YD 20. 14 TO 16 PRIS YD 24. ZD 48. YB 18. ZB 12. 17 TO 19 PR YD 24. ZD 18. ZB 12.

In the above input, the first set of members are rectangular (40 cm depth and 20 cm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with 20 cm diameter. Note that no area (AX) is provided for these members. For concrete design, this property must not be provided. If shear areas and moments of inertias are not provided, the program calculates these values from YD and ZD. Notice that in the above example the IZ and IY values provided are actually 50% of the values calculated using YD and ZD. This is a conventional practice which takes into consideration revised section parameters due to cracking of section.

Page 509: International Design Codes

Section 10A 10-3

Note that the third and the fourth set of members in the above example represent a T-shape and a TRAPEZOIDAL shape respectively. Depending on the properties (YD, ZD, YB, ZB, etc.) provided, the program will determine whether the section is rectangular, trapezoidal or T-shaped and the BEAM design will be done accordingly.

10A.4 Design Parameters

The program contains a number of parameters which are needed to perform design by the Mexican code. Default parameter values have been selected such that they are frequently used numbers for conventional design requirements. These values may be changed to suit the particular design being performed. Table 3.1 is a complete list of the available parameters and their default values. The manual describes the commands required to provide these parameters in the input file. For example, the values of SFACE and EFACE (parameters that are used in shear design), the distances of the face of supports from the end nodes of a beam, are assigned values of zero by default but may be changed depending on the actual situation. Similarly, beams and columns are designed for moments directly obtained from the analyses without any magnification. The factors MMAGx and MMAGy may be used for magnification of column moments. For beams, the user may generate load cases which contain loads magnified by the appropriate load factors.

Page 510: International Design Codes

Concrete Design Per Mexican Code Section 10A 10-4

Table 10A.1 – Mexican Concrete Design Parameters Parameter Default Description Name Value

FYMAIN 4200Kg/cm2 Yield Stress for main reinforcing steel FYSTIRR 4200Kg/cm2 Yield Stress for stirrup reinforcing steel FC 200Kg/cm2 Compressive Strength of Concrete

clear_cover_top 3cm Clear cover for top reinforcement clear_cover_bottom 3cm Clear cover for bottom reinforcement

clear_cover_side 3cm Clear cover for side reinforcement MINMAIN** No 2.5 bar Minimum main reinforcement bar size (Number 2 -18)

MINSEC** No 2.5 bar Minimum secondary reinforcement bar size (Number 2 -18)

MAXMAIN** No 12 bar Maximum main reinforcement bar size (Number 2 -18)

SFACE 0

Face to support location of start of beam. If specified, for shear force at start is computed at a distance of SFACE+d from the start joint of the member. Positive number

EFACE 0

Face to support location of end of beam. If specified, for shear force at start is computed at a distance of EFACE+d from the start joint of the member. Positive number.

REINF 0 Tied Column. A value of 1 will mean spiral. AMAGx AMAGy 1 A factor by which the column design moments will be

magnified

WIDTH *ZD Width of concrete member. This value defaults to ZD as provided under MEMBER PROPERTIES

DEPTH *YD Depth of concrete member. This value defaults to YD as provided under MEMBER PROPERTIES

NSECTION 12 Number of equally-spaced sections to be considered in finding critical moments for beam design

Page 511: International Design Codes

Section 10A 10-5

Table 10A.1 – Mexican Concrete Design Parameters Parameter Default Description Name Value

TRACK 0

Beam Design 0 = Critical Moment will not be printed out with

beam design report. 1 = will mean a print out. 2 = will print out required steel areas for all

intermediate sections specified by NSECTION. Column Design 0 = will print out detailed design results. 1 = will mean a print out column interation analysis

results in addition to TRACK 0 output. 2 = will print out a schematic interaction diagram and

intermediate interaction values in addition to all of the above.

BARTYPE 2 0: IMPERIAL (No 3 to 18) 1: METRIC (4.2 to 60mm) 2: MEXICAN (No 2 to 18)

DIM_PRECAUTION TRUE TRUE:Precautions are taken to assure dimensions FALSE: Not precautions taken - Section reduction to section 1.5 NTC Concrete

EXPOSED_SOIL_ WEATHER

FALSE Exposition to soil or weather to define cover and min Steel reinforcement

CONC_CLAS 1 Concrete class according to 1.4.1d) to define Modulus of Elasticity

LIGHT_CONC FALSE Light Concrete to define development multipliers according to table 3.1 NTC

COLD_FORM_BAR FALSE Cold formed Bar to define development multipliers according to table 3.1 NTC

DUCTILE_SEISMIC _DESIGN

TRUE DUCTILE FRAMES ACCORDING TO SECTION 5. Some design conditions are considered (not including, for the time being, geometric or confinment ones)

DIAM_AG *2 cm MAXIMUM DIAM AGGREGATE BEARED_PERIM TRUE Slab beared perimeter. To calculate min steel required

according to 2.1.2

Page 512: International Design Codes

Concrete Design Per Mexican Code Section 10A 10-6

Table 10A.1 – Mexican Concrete Design Parameters Parameter Default Description Name Value

DIRECT_COMP TRUE Beam Loads and reactions in direct compression Cl-2.1.5.a.I 2nd paragraph

PHI 90 degrees Stirrups angle with the axis of the element TORSIONAL_ EQUILIBRIUM

FALSE Beam needed for torsional equilibrium Cl.2.1.6a) 2nd paragraph

Pfact 1.0 Part of the longitudinal steel considered to reduce shear. 0(zero) is on the safe side. Value between 1 and 0.

ZB 0.0 IDEM ACI YB 0.0 IDEM ACI EIT *198000

Kg/cm2 CONCRETE MODULUS OF ELASTICITY

* These values must be provided in the current unit system being used. ** When using metric bars for design, provide values for these parameters in actual ‘mm‘ units instead of the bar number. The following metric bar sizes are available: 4.2mm, 6 mm, 8 mm, 10 mm, 12 mm, 16 mm, 20 mm, 25 mm, 32 mm, 40 mm, 50 mm and 60 mm.

10A.5 Beam Design

Beams are designed for flexure, shear and torsion. For all these forces, all active beam loadings are prescanned to locate the possible critical sections. The total number of sections considered is 12 (twelve) unless this number is redefined with an NSECTION parameter. All of these equally spaced sections are scanned to determine moment and shear envelopes. Design for Flexure Reinforcement for positive and negative moments are calculated on the basis of the section properties provided by the user. If the section dimensions are inadequate to carry the applied load, that is if the required reinforcement is greater than the maximum allowable for the cross section, the program reports that beam fails in maximum reinforcement. Rectangular sections are also designed with compression reinforcement.

Page 513: International Design Codes

Section 10A 10-7

Effective depth is chosen as Total depth - (Clear cover + diameter of stirrup + half the dia. of main reinforcement), and a trial value is obtained by adopting proper bar sizes for the stirrups and main reinforcements. The relevant clauses in Sections 1.5, 1.6, 2.1.1-2-5, 3.10 and 5.2.2 of NTC Concrete are utilized to obtain the actual amount of steel required as well as the maximum allowable and minimum required steel. These values are reported as ROW, ROWMX and ROWMN in the output and can be printed using the parameter TRACK 1.0 (see Table 10A.1). In addition, the maximum, minimum and actual bar spacing are also printed. It is important to note that beams are designed for flexural moment MZ only. The moment MY is not considered in the flexural design. Design for Shear Shear reinforcement is calculated to resist both shear forces and torsional moments. Shear forces are calculated at a distance (d+SFACE) and (d+EFACE) away from the end nodes of the beam. SFACE and EFACE have default values of zero unless provided under parameters (see Table 10A.1). Note that the value of the effective depth "d" used for this purpose is the update value and accounts for the actual c.g. of the main reinforcement calculated under flexural design. Clauses 2.1.5-6 and 5.2.4 of NTC Concrete are used to calculate the reinforcement for shear forces and torsional moments. Based on the total stirrup reinforcement required, the size of bars, the spacing, the number of bars and the distance over which they are provided are calculated. Stirrups due to geometric conditions are assumed to be 2-legged, due to design conditions could be 2 or 4-legged. Design for Anchorage In the output for flexural design, the anchorage details are also provided. At any particular level, the START and END coordinates of the layout of the main reinforcement is described along with the information whether anchorage in the form of a hook or continuation is required or not at these START and END points. Note that the coordinates of these START and END points are obtained after taking into account the anchorage requirements.

Page 514: International Design Codes

Concrete Design Per Mexican Code Section 10A 10-8

Anchorage length is calculated on the basis of the Clauses described in Section 3.1 of NTC concrete. In case the program selects 2 different diameters for the main or compression reinforcement, only the anchorage for the largest diameter is analyzed.

Output

Page 515: International Design Codes

Section 10A 10-9

ACTUAL OUTPUT FROM DESIGN

===================================================================== BEAM NO. 1 DESIGN RESULTS - FLEXURE PER CODE NTC FOR THE DESIGN AND CONSTRUCTION OF CONCRETE STRUCTURES,DDF LEN - 525.00(cm) FY - 4200. FC - 250. SIZE - 30.00 X 80.00(cm) LEVEL HEIGHT BAR INFO FROM TO ANCHOR (cm) (cm) (cm) STA END _____________________________________________________________________ 1 4. 8 - -NUM, 5 0. 39. YES NO 1 4. 1 - -NUM, 4 0. 39. 2 8. 3 - -NUM, 5 0. 39. YES NO |----------------------------------------------------------------| | CRITICAL MOMENT=5978000.50 Kg cm AT 0.00 (cm)LOAD 1| | REQD STEEL= 24.41 (cm2)ROW=0.0109 ROWMX=0.0190 ROWMN=0.0026 | | REQD COMP STEEL= 0.00 (cm2) | | MAX/MIN/ACTUAL BAR SPACING= 24.14/ 3.18/ 3.45 (cm) | | COMP MAX/MIN/ACTUAL BAR SPACING= 0.00/ 0.00/ 0.00 (cm) | | BASIC/REQD. DEVELOPMENT LENGTH = 40.07/ 39.08(cm) | |----------------------------------------------------------------| Cracked Moment of Inertia Iz at above location = 1015658.4 cm^4 3 77. 10 - -NUM, 4 0. 45. YES NO 4 73. 9 - -NUM, 4 0. 45. YES NO |----------------------------------------------------------------| | CRITICAL MOMENT=5978000.50 Kg cm AT 0.00 (cm)LOAD 1| | REQD STEEL= 24.17 (cm2)ROW=0.0107 ROWMX=0.0190 ROWMN=0.0026 | | REQD COMP STEEL= 0.00 (cm2) | | MAX/MIN/ACTUAL BAR SPACING= 24.46/ 2.54/ 2.72 (cm) | | COMP MAX/MIN/ACTUAL BAR SPACING= 0.00/ 0.00/ 0.00 (cm) | | BASIC/REQD. DEVELOPMENT LENGTH = 32.00/ 44.81(cm) | |----------------------------------------------------------------|Cracked Moment of Inertia Iz at above location = 1008728.7 cm^4 REQUIRED REINF. STEEL SUMMARY : ------------------------------- SECTION REINF STEEL(+VE/-VE) MOMENTS(+VE/-VE) LOAD(+VE/-VE) ( CM ) (SQ. CM ) (KG -CM ) 0.00 24.67/ 24.67 5978000./ 5978000.50 0/ 0 525.00 24.67/ 24.67 5978000./ 5978000.50 0/ 0 B E A M N O. 1 D E S I G N R E S U L T S – SHEAR AT START SUPPORT - Vu=41850.00 Kg Vc= 6074.49 Kg Vs=44719.39 Kg Tu= 0.00 Kg cm Tc= 0.00 Kg cm Ts= 0.00 Kg cm LOAD 0 NO STIRRUPS ARE REQUIRED FOR TORSION. REINFORCEMENT IS REQUIRED FOR SHEAR. PROVIDE NUM. 2.5 2-LEGGED STIRRUPS AT 7.(cm) C/C FOR 176.(cm) ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.00 (cm2) AT END SUPPORT - Vu=37450.00 Kg Vc= 6074.49 Kg Vs=39219.39 Kg Tu= 0.00 Kg cm Tc= 0.00 Kg cm Ts= 0.00 Kg cm LOAD 0 NO STIRRUPS ARE REQUIRED FOR TORSION. REINFORCEMENT IS REQUIRED FOR SHEAR. PROVIDE NUM. 2.5 2-LEGGED STIRRUPS AT 8.(cm) C/C FOR 176.(cm) ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.00 (cm2)

Page 516: International Design Codes

Concrete Design Per Mexican Code Section 10A 10-10

10A.6 Column Design

Columns design in STAAD per the Mexican code is performed for axial force and uniaxial as well as biaxial moments. All active loadings are checked to compute reinforcement. The loading which produces the largest amount of reinforcement is called the critical load. Column design is done for square, rectangular and circular sections. For rectangular and circular sections, reinforcement is always assumed to be equally distributed on all faces. This means that the total number of bars for these sections will always be a multiple of four (4). If the MMAGx & -MMAGy parameters are specified, the column moments are multiplied by the corresponding MMAG value to arrive at the ultimate moments on the column. Minimum eccentricity conditions to be satisfied according to section 2.1.3.a are checked. Method used: Bresler Load Contour Method Known Values: Pu, Muy, Muz, B, D, Clear cover, Fc, Fy Ultimate Strain for concrete : 0.003 Steps involved : 1. Assume some reinforcement. Minimum reinforcement (1% for

ductile design or according to section 4.2.2 ) is a good amount to start with.

2. Find an approximate arrangement of bars for the assumed reinforcement.

3. Calculate PNMAX = Po, where Po is the maximum axial load capacity of the section. Ensure that the actual nominal load on the column does not exceed PNMAX. If PNMAX is less than the axial force Pu/FR, (FR is the strength reduction factor) increase the reinforcement and repeat steps 2 and 3. If the reinforcement exceeds 6% (or 4% for ductile design), the column cannot be designed with its current dimensions.

4. For the assumed reinforcement, bar arrangement and axial load, find the uniaxial moment capacities of the column for the

Page 517: International Design Codes

Section 10A 10-11

Y and the Z axes, independently. These values are referred to as MYCAP and MZCAP respectively.

5. Solve the Interaction Bresler equation: α α

Mny Mnz ⎯⎯⎯⎯ + ⎯⎯⎯

Mycap Mycap Where a = 1.24. If the column is subjected to uniaxial moment: a =1 6. If the Interaction equation is satisfied, find an arrangement

with available bar sizes, find the uniaxial capacities and solve the interaction equation again. If the equation is satisfied now, the reinforcement details are written to the output file.

7. If the interaction equation is not satisfied, the assumed reinforcement is increased (ensuring that it is under 6% or 4% respectively) and steps 2 to 6 are repeated.

By the moment to check shear and torsion for columns the sections have to be checked as beams and the most strict of both shear and torsion reinforcement adopted.

10A.7 Column Interaction

The column interaction values may be obtained by using the design parameter TRACK 1.0 or TRACK 2.0 for the column member. If a value of 2.0 is used for the TRACK parameter, 12 different Pn-Mn pairs, each representing a different point on the Pn-Mn curve are printed. Each of these points represents one of the several Pn-Mn combinations that this column is capable of carrying about the given axis, for the actual reinforcement that the column has been designed for. In the case of circular columns, the values are for any of the radial axes. The values printed for the TRACK 1.0 output are:

Page 518: International Design Codes

Concrete Design Per Mexican Code Section 10A 10-12

P0 = Maximum allowable pure axial load on the column (moment zero). Pnmax = Maximum allowable axial load on the column. P_bal = Axial load capacity of balanced strain condition. M_bal = Uniaxial moment capacity of balanced strain condition. E_bal = M_bal / P_bal = Eccentricity of balanced strain condition. M0 = Moment capacity at zero axial load. P_tens = Maximum permissible tensile load on the column. Des. Pn = Pu/FR where FR is the Strength Reduction Factor and Pu is the axial

load for the critical load case. Des.Mnx = Mux*MMAGx/FR where FR is the Strength Reduction Factor and Mu

is the bending moment for the appropriate axis for the critical load case.

Mu = √ (Mux.Mmagx)²+ (Muy.Mmagy)² e/h = (Mn/Pn)/h where h is the length of the column

10A.8 Column Design Output

The next table illustrates different levels of the column design output.

Page 519: International Design Codes

Section 10A 10-13

The output is generated without any TRACK specification: ==================================================================== COLUMN NO. 1 DESIGN PER - AXIAL + BENDING FY -4200.0 FC - 294.1 Kg/cm2 CIRC SIZE 100.0(cm)DIAMETER AREA OF STEEL REQUIRED = 128.506 BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI ---------------------------------------------------------- 46 - NUMBER 6 1.669 1 END 0.700 (EQUALLY SPACED) TRACK=1 generates the following additional output: COLUMN INTERACTION: MOMENT ABOUT Z/Y -AXIS (Kg-cm ) -------------------------------------------------------- P0 Pn max P-bal. M-bal. e-bal.(cm) 2095196.38 2095196.38 727411.12 29235398.00 40.2 M0 P-tens. Des.Pn 'Des.Mn e/h 20606994.00 -550620.00 0.00 20000000.00 NaN -------------------------------------------------------- TRACK=2 generates the following output in addition to all the above: Pn Mn Pn Mn | 1934027.38 5373253.50 967013.69 27278232.00 P0 |* 1772858.50 11408365.00 805844.75 28658428.00 | * 1611689.50 16296947.00 644675.81 29473708.00 Pn,max|__* 1450520.62 20083028.00 483506.84 28901764.00 | * 1289351.62 23117562.00 322337.91 27205616.00 Pn | * 1128182.62 25462606.00 161168.95 24433192.00 NOMINAL| * AXIAL| * COMPRESSION| * Pb|-------*Mb | * ___________|____*_______ | * M0 Mn, | * BENDING P-tens|* MOMENT

10A.9 Slab Design

Slab are designed per Mexican NTC specifications. To design a slab, it must be modeled using finite elements. Element design will be performed only for the moments MX and MY at the center of the element. Design will not be performed for FX, FY, FXY, MXY. Also, design is not performed at any other point on the surface of the element. Shear is checked with Q. A typical example of element design output is shown below. The reinforcement required to resist Mx moment is denoted as

Page 520: International Design Codes

Concrete Design Per Mexican Code Section 10A 10-14

longitudinal reinforcement and the reinforcement required to resist My moment is denoted as transverse reinforcement. The parameters FYMAIN, FC, CLEAR, DIM_PRECAUTION, and EXPOSED_SOIL_WEATHER listed in Table 3.1 are relevant to slab design. Other parameters mentioned are not used in slab design.

ELEMENT DESIGN SUMMARY ---------------------- ELEMENT LONG. REINF MOM-X /LOAD TRANS. REINF MOM-Y /LOAD (SQ.CM/M ) (T -M /M ) (SQ.CM/M ) (T -M /M ) 1 TOP : Longitudinal direction - Only minimum steel required. 1 BOTT: Transverse direction - Only minimum steel required. 1 TOP : 2.239 0.00 / 0 3.252 983.00 / 1 BOTT: 3.758 983.00 / 1 1.684 0.00 / 0 1 SHEAR CAPACITY 3794.73 Kg ***PASS***

Page 521: International Design Codes

10-15

Steel Design per Mexican Code

Section 10B

10B.1 General

The program is based in: Complementary Technical Standards for the Design and Construction of Steel Structures – Dec. 1987. (Normas Técnicas Complementarias para Diseño y construcción de Estructuras Metálicas) of the Mexican Construction Code for the Federal District –Aug. 1993 (Reglamento de Construcciones para el Distrito Federal). The design philosophy considered is that of the Load Cases and Resistance Method or Limit States Design usually known as Load and Resistance Factor Design (LRFD). Structures are designed and proportioned taking into consideration the limit states at which they would become unfit for their intended use. Two major categories of limit-state are recognized--ultimate and serviceability. The primary considerations in ultimate limit state design are strength and stability, while that in serviceability is deflection. Appropriate load and resistance factors are used so that a uniform reliability is achieved for all steel structures under various loading conditions and at the same time the chances of limits being surpassed are acceptably remote. In the STAAD implementation of the Mexican Standards for steel structures, members are proportioned to resist the design loads without exceeding the limit states of strength, and stability. It allows to check deformation to verify serviceability. Accordingly, the most economic section is selected on the basis of the least weight criteria as augmented by the designer in

Page 522: International Design Codes

Steel Design Per Mexican Code Section 10B 10-16

specification of allowable member depths, desired section type, or other such parameters. The code checking portion of the program checks that main code requirements for each selected section are met and identifies the governing criteria. The following sections describe the salient features of the Mexican specifications as implemented in STAAD steel design. A brief description of the fundamental concepts is presented here.

10B.2 Limit States Design Fundamentals

The primary objective of the Limit States Design Specification is to provide a uniform reliability for all steel structures under various loading conditions. The Limit States Design Method uses separate factors for each load and resistance. Because the different factors reflect the degree of uncertainty of different loads and combinations of loads and of the accuracy of predicted strength, a more uniform reliability is possible. The method may be summarized by the inequality Yi Qi < Rn FR On the left side of the inequality, the required strength is the summation of the various load effects, Qi, multiplied by their respective load factors, yi. The design strength, on the right side, is the nominal strength or resistance, Rn, multiplied by a resistance factor, FR. In the STAAD implementation of the Mexican Standards, it is assumed that the user will use appropriate load factors and create the load combinations necessary for analysis. The design portion of the program will take into consideration the load effects (forces and moments) obtained from analysis. In calculation of resistances of various elements (beams, columns etc.), resistance (nominal strength) and applicable resistance factor will be automatically considered.

Page 523: International Design Codes

Section 10B 10-17

10B.3 Member End Forces and Moments

Member end forces and moments in the member result from loads applied to the structure. These forces are in the local member coordinate system. the following figures show the member end actions with their directions.

Page 524: International Design Codes

Steel Design Per Mexican Code Section 10B 10-18

10B.4 Section Classification

The Limit States Design specification allows inelastic deformation of section elements. Thus local buckling becomes an important criterion. Steel sections are classified as compact (type 2), noncompact (type 3), or slender element(type 4), sections depending upon their local buckling characteristics, besides sections type 1 are able for plastic design. This classification is a function of the geometric properties of the section. The design procedures are different depending on the section class. STAAD is capable of determining the section classification for the standard shapes and design accordingly.

10B.5 Member in Axial Tension

The criteria governing the capacity of tension members is based on two limit states. The limit state of yielding in the gross section is intended to prevent excessive elongation of the member. The second limit state involves fracture at the section with the minimum effective net area. The net section area may be specified by the user through the use of the parameter NSF (see Table 10B.1), that always refers to the gross section. STAAD calculates the tension capacity of a given member based on these two limit states and proceeds with member selection or code check accordingly. In addition to the tension resistance criterion, the user defines if tension members are required to satisfy slenderness limitations which are a function of the nature of use of the member (main load resisting component, bracing member, etc.). In both the member selection and code checking process, STAAD immediately does a slenderness check on appropriate members before continuing with other procedures for determining the adequacy of a given member.

Page 525: International Design Codes

Section 10B 10-19

10B.6 Axial Compression

The column strength equations take into account inelastic deformation and other recent research in column behavior. Two equations governing column strength are available, one for inelastic buckling and the other for elastic or Euler buckling. Both equations include the effects of residual stresses and initial out-of-straightness. Compression strength for a particular member is calculated by STAAD according to the procedure outlined in Section 3.2 of the NTC. For slender elements, the procedure described in Section 2.3.6.NTC is also used. The procedures of Section 3.2 of the Commentaries, design helps and examples of the Complementary Technical Standards for the Design and Construction of Steel Structures (de los Comentarios, ayudas de diseño y ejemplos de las Normas Técnicas Complementarias para el Diseño y Construcción de Estructuras Metálicas, DDF (Comentarios - Julio 1993) were implemented for the determination of design strength for these limit states. Effective length for calculation of compression resistance may be provided through the use of the parameters KY, KZ and/or LY, LZ. If not provided, the entire member length will be taken into consideration. In addition to the compression resistance criterion, compression members are required to satisfy slenderness limitations which are a function of the nature of use of the member (main load resisting component, bracing member, etc.). In both the member selection and code checking process, STAAD immediately does a slenderness check on appropriate members before continuing with other procedures for determining the adequacy of a given member.

Page 526: International Design Codes

Steel Design Per Mexican Code Section 10B 10-20

10B.7 Flexural Design Strength

In the Limit States Design Method, the flexural design strength of a member is determined mainly by the limit state of lateral torsional buckling. Inelastic bending is allowed and the basic measure of flexural capacity is the plastic moment capacity of the section. The flexural resistance is a function of plastic moment capacity, actual laterally unbraced length, limiting laterally unbraced length, buckling moment and the bending coefficient. The limiting laterally unbraced length Lu and flexural resistance Mr are functions of the section geometry and are calculated as per the procedure of Section 3.3.2 of the NTC. The purpose of bending coefficient Cb is to account for the influence of the moment gradient on lateral-torsional buckling. This coefficient can be specified by the user through the use of parameter CB or CBy (see Table 10B.1) or may be calculated by the program (according to LRDF USA specification) if CB is specified as 0.0. In the absence of the parameter CB, a default value of 1.0 will be used. To specify laterally unsupported length, either of the parameters UNL and UNF (see Table 10B.1) can be used. It is taken into account the reduction of flexural resistance due to slender web according to section 4.5.8 of the NTC For the sections where the web and flange are slender the LRDF USA specification was used.

Page 527: International Design Codes

Section 10B 10-21

Stress areas due to bending about y axis (MY)

Notes: the local X axis goes into the page; the Global Y axis is vertical upwards; the shaded area indicates area under compression; the area not shaded indicates area under tension. Stress areas due to bending about Z axis (MZ)

Page 528: International Design Codes

Steel Design Per Mexican Code Section 10B 10-22

10B.8 Design for Shear

The procedure of Sect. 3.3.3 of the NTC is used in STAAD to design for shear forces in members. Besides combined bending and shear is checked according to section 3.3.4 of the NTC, considering also the limits for stiffeners of the web according to sections 4.5.6/7 of the NTC. Shear in wide flanges and channel sections is resisted by the area of the web/s..

10B.9 Combined Compression Axial Force and Bending

The interaction of flexure and axial forces in singly and doubly symmetric shapes is governed by formulas of the Section 3.4 of the NTC. These interaction formulas cover the general case of biaxial bending combined with axial force. They are also valid for uniaxial bending and axial force. It is considered that the frames are part of structures that have shear walls or rigid elements so that the lateral displacements of a floor could be disregarded. The program has included formulas to include structures with lateral displacements in the future considering for B2 the columns individually and not the complete floor analysis. It is taken into account if the elements have transverse loads and if the ends are angularly restrained.

10B.10 Combined Tension Axial Force and Bending

Based on Section 3.5 4 of the NTC.

Page 529: International Design Codes

Section 10B 10-23

10B.11 Design Parameters

Design per Mexican Standards is requested by using the CODE. Other applicable parameters are summarized in Table 10B.1. These parameters communicate design decisions from the engineer to the program and thus allow the engineer to control the design process to suit an application's specific needs. The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements, some or all of these parameter values may be changed to exactly model the physical structure. The parameters DMAX and DMIN may only be used for member selection only.

Page 530: International Design Codes

Steel Design Per Mexican Code Section 10B 10-24

TABLA 10B.1. DESIGN PARAMETERS ACCORDING TO MEXICAN STANDARS - STEEL Parameter Default Description Name Value KX 1.0 K value for flexural-torsional buckling KY 1.0 K value in local Y axis- Usually minor axis KZ 1.0 K value in local Z axis- Usually major axis LX Member

length Length for flexural-torsional buckling

LY Member length

Length to calculate slenderness ratio for buckling about local Y axis.

LZ Member length

Length to calculate slenderness ratio for buckling about local Z axis.

FYLD 2530 kg/cm2 Minimum Yield strength of steel FU 4230 Kg/cm2 Ultimate tensile strength of steel NSF 1 Net section factor for tension members UNT Member

length Unsupported length (L) of the top* flange for calculating flexural strength . Will be used only if compression is in the top flange.

UNB Member length

Unsupported length (L) of the bottom* flange for calculating flexural strength . Will be used only if compression is in the bottom flange.

STIFF Member length

Spacing of stiffeners for beams for shear design

Cb y Cby 1 Coefficient C defined per section 3.3.2.2. If Cb is set to 0.0 it will be calculated by the program according to LRFD USA (CbMex=1/CbUSA). Any other value will be directly used in the design.

TRACK 0 0 = Supress all design strengths 1 = Print all design strengths 2 = Print expanded design output

DMAX 114 cm Maximum allowable depth DMIN 0.0 cm Minimum allowable depth RATIO 1.0 Permissible ratio of actual load effect and design strength BEAM 0 0: Design at ends and those locations specified by

SECTION command. 1: Design at ends and at every y cada 1/12th point along member length

Rigid_to_H_Lo

TRUE Defines if the structure has elements to bear the wind load ( shear walls, wind trusses or bracing rigid elements )

Page 531: International Design Codes

Section 10B 10-25

TABLA 10B.1. DESIGN PARAMETERS ACCORDING TO MEXICAN STANDARS - STEEL Parameter Default Description Name Value ads that restrict lateral displacements and allow to disregard

slenderness effects. IRREG 0 Variable defined for the whole structure indicating if it is

regular or irregular according to section 3.4 of the NTC. IRREG=1 for columns being part of irregular structures.

I_NO_OXIG 0 Defined for I shapes or tubes Curve Definition according to NTC.3.2.2.1a) I_NO_OXIG.= 0 implies n=1.4 laminated I shapes, tubes or built up with 3 or 4 welded plates obtained from wider plates cuts with oxygen. I_NO_OXIG.= 1 implies n=1 I shapes, tubes or built up with 3 or 4 welded plates n is defined by the program

IMAIN_MEM 0 IMAIN_MEM=0 MAIN MEMBER IMAIN_MEM=1 Secondary and wind trusses

Ccomb 1 Cfactor for combined forces when there are tranverse loads in the members. Section 3.4.3.3.ii NTC Ccomb=1 If members ends are restricted angularly. Ccomb=0.85 If members ends are not restricted angularly.

DUCTILE_SEISMIC _DESIGN

TRUE DUCTILE FRAMES ACCORDING TO SECTION 11. Main design conditions are considered (not including, at the moment, geometric ones)

* Top and Bottom represent the positive and negative side of the local Y axis (local Z axis if SET Z UP is used. Note: For deflection check, parameters DFF, DJ1 and DJ2 from Table 2.1 may be used. All requirements remain the same.

10B.12 Code Checking and Member Selection

Both code checking and member selection options are available in STAAD Mexican Standards implementation.

Page 532: International Design Codes

Steel Design Per Mexican Code Section 10B 10-26

10B.13 Tabulated Results of Steel Design

Results of code checking and member selection are presented in a tabular format. CRITICAL COND refers to the section of the Mexican NTC which governed the design. If the TRACK is set to 1.0, member design strengths will be printed out.

Page 533: International Design Codes

Section 11 Russian Codes

Page 534: International Design Codes
Page 535: International Design Codes

11-1

Concrete Design Per Russian Code (SNiP 2.03.01-84*)

Section 11A

11A.1 General

Russian Code SNiP 2.03.01−84* “Plain concrete and concrete structures” is based on the method of limit states. Code SNiP 2.03.01−84* defines two groups of limit states. Analysis according to the first group of limit states is performed to avoid the following phenomena: • brittle, plastic or other type of failure, • loss by structure of stable form or position, • fatigue failure, • failure due to the action of load actions and unfavourable

environmental effects.

Analysis according to the second group of limit states is performed to avoid the following phenomena: • excessive and longterm opening of cracks if they are allowed

according to service conditions, • excessive displacements. Analysis of structures for the first group of limit states is performed with the use of the maximum (design) loads and actions. Analysis of structures for the second group of limit states is made in accordance with the operational (normative) loads and actions. Ratio between design and normative loads is called reliability coefficient for loads which is determined according to SNiP 2.01.07.-85 “Loads and actions”.

Page 536: International Design Codes

Concrete Design Per Russian Code Section 11A 11-2

Reliability coefficient γn for destination according to SNiP 2.01.07.-85 shall be considered in determination of loads and their combinations. Program STAAD/Pro makes it possible to calculate reinforcement for concrete members according to codes of many countries round the World and Russian Code SNiP 2.03.01−84* inclusive. Algorithms for calculation of reinforcement of concrete linear (beams, columns) and 2D (two dimensional) (slabs, walls, shells) members are incorporated in program STAAD/Pro. Not only Code SNiP 2.03.01−84* but also the “Guide for design of plain concrete and reinforced concrete structures from normal weight and lightweight concrete (to SNiP 2.03.01−84)” have been used in creation of these algorithms. It is possible using program STAAD/Pro to calculate reinforcement for beams of rectangular or T section and for columns of rectangular or circular section (Fig.1).

Figure 1 - Notation of dimensions for rectangular, circular and T sections Flange of T-shape beams may be situated at the top zone of the section if the angle BETA=00, or at the bottom zone of the section, if BETA=1800.

Page 537: International Design Codes

Section 11A 11-3

11A.2 Input Data

Entry of data of cross-sections of beams and columns is made by the use of MEMBER PROPERTIES command, and thicknesses of 2D members are entered by ELEMENT PROPERTY command. Example: UNIT MM MEMBER PROPERTIES * Columns of rectangular cross-section 1 TO 16 PRI YD 350. ZD 350. * Columns of circular cross-section 17 TO 22 PRI YD 350. * Beams of T cross-section 23 TO 40 PRI YD 450. ZD 550. YB 230. ZB 200. UNIT METER ELEMENT PROPERTY 41 TO 100 THICKNESS 0.14 101 TO 252 THICKNESS 0.16 * Flange of T beams is located at the bottom zone of cross-section BETA 180. MEMB 23 TO 40 Commands for calculation of reinforcement are located in the input data file after the command of analysis and as a rule, after output commands to print results of calculation. Example: * Command of analysis PERFORM ANALYSIS . .* Output command to print results of calculation (according to user’s judgment) .

Page 538: International Design Codes

Concrete Design Per Russian Code Section 11A 11-4

* Command of loading and their combinations considered in design LOAD LIST 1 5 TO 9 * Command to start reinforcement calculation procedure START CONCRETE DESIGN CODE RUSSIAN .* List of parameters being used in reinforcement calculation . . BCL 20. MEMB 17 TO 22 CL1 0.04 MEMB 1 TO 40 DD2 10. MEMB 23 TO 40 CRA 0.036 MEMB 41 TO 252 . . . * Command of beam reinforcement calculation DESIGN BEAM 23 TO 40 * Command of column reinforcement calculation DESIGN COLUMN 1 TO 22 * Command of calculation 2D elements (slabs, walls, shells) DESIGN ELEMENT 41 TO 252 * Command of interruption reinforcement calculation END CONCRETE DESIGN In tables 1, 2 and 3 information about parameters used for calculation of reinforcement for beams, columns and 2D (two dimensional) members is presented. Values of parameters do not depend on UNIT command. In the file of input data only such parameters have to be taken, the values of which differ from determined in the program.

Page 539: International Design Codes

Section 11A 11-5

Table 1- Names of parameters for Concrete design according to Russian Code СНиП 2.03.01−84* for beams

No. Parameter

name Default value

Description

1 NLT 1 Number of long-term loading case

2 RCL 3

Class of longitudinal reinforcement: • RCL = 1, if class of reinforcement is A-I; • RCL = 2, if class of reinforcement is A-II; • RCL = 3, if class of reinforcement is A-III; • RCL = 33, if class of reinforcement is A-IIIb; • RCL = 4, if class of reinforcement is A-IV; • RCL = 5, if class of reinforcement is A-V; • RCL = 6, if class of reinforcement is A-VI; • RCL = 7, if class of reinforcement is A-VII; • RCL = 77, if class of reinforcement is K-7; • RCL = 8, if class of reinforcement is B-II; • RCL = 9, if class of reinforcement is Bp-II; • RCL = 10, if class of reinforcement is Bp-I; • RCL = 19, if class of reinforcement is K-19

3 USM 1. Total product of service conditions coefficients for longitudinal reinforcement (γs)

4 UB2 0.9 Specific service conditions coefficient for concrete (γb2)

5 DD1 16. Diameter of longitudinal reinforcement bars in beam tension zone

6 DD2 16. Diameter of shear reinforcement bars for beam; 7 BCL 15. Compression class of concrete

8 UBM 1. Product of service conditions coefficients for concrete, except UB2 (γb)

9 TEM 0. Parameter of concrete hardening conditions: • TEM=0, for natural hardening conditions; • TEM=1, for steam hardening conditions

10 CL1 0.05 Distance from top/bottom fiber of beam cross section to the center of longitudinal reinforcement bar;

11 CL2 0.05 Distance from left/right side of beam cross section to the center of longitudinal reinforcement bar

Page 540: International Design Codes

Concrete Design Per Russian Code Section 11A 11-6

No. Parameter

name Default value

Description

12 WST 0.4 Ultimate width of short-term crack 13 WLT 0.3 Ultimate width of long-term crack

14 SSE 0

Limit state parameter for beam design • SSE=0, if calculation of reinforcement

amount must be carried out according to the requirements of load carrying capacity (the first limit state);

• SSE=1, if calculation of reinforcement amount must be carried out according to the cracking requirements (the second limit state)

15 RSH 1

Class of shear reinforcement: • RSH = 1, if class of reinforcement is A-I; • RSH = 2, if class of reinforcement is A-II; • RSH = 3, if class of reinforcement is A-III; • RSH = 33, if class of reinforcement is A-

IIIb; • RSH = 4, if class of reinforcement is A-IV; • RSH = 5, if class of reinforcement is A-V; • RSH = 6, if class of reinforcement is A-VI; • RSH = 7, if class of reinforcement is A-VII; • RSH = 77, if class of reinforcement is K-7; • RSH = 8, if class of reinforcement is B-II; • RSH = 9, if class of reinforcement is Bp-II; • RSH = 10, if class of reinforcement is Bp-I; • RSH = 19, if class of reinforcement is K-19

16 FWT ZD Design width of beam top flange. Use for beam design only with default value provided as ZD in member properties.

17 FWB ZB Design width of beam bottom flange. Use for beam design only with default value provided as ZB in member properties.

18 DEP YD Design depth of beam section. Use for beam design only with default value provided as YD in member properties.

19 SFA 0. Face of support location at the start of the beam.

Page 541: International Design Codes

Section 11A 11-7

No. Parameter

name Default value

Description

Use for beam design only.

20 EFA 0. Face of support location at the end of the beam. Use for beam design only.

21 NSE 13 Number of equally-spaced sections for beam design. Use for beam design only. Upper limit is equal to 20.

Table 2 - Names of parameters for Concrete design according to Russian Code СНиП 2.03.01−84* for columns

No. Parameter

name Default value

Description

1 NLT 1 Number of long-term loading case

2 RCL 3

Class of longitudinal reinforcement: • RCL = 1, if class of reinforcement is A-I; • RCL = 2, if class of reinforcement is A-II; • RCL = 3, if class of reinforcement is A-III; • RCL = 33, if class of reinforcement is A-IIIb; • RCL = 4, if class of reinforcement is A-IV; • RCL = 5, if class of reinforcement is A-V; • RCL = 6, if class of reinforcement is A-VI; • RCL = 7, if class of reinforcement is A-VII; • RCL = 77, if class of reinforcement is K-7; • RCL = 8, if class of reinforcement is B-II; • RCL = 9, if class of reinforcement is Bp-II; • RCL = 10, if class of reinforcement is Bp-I; • RCL = 19, if class of reinforcement is K-19

3 USM 1. Total product of service conditions coefficients for longitudinal reinforcement (γs)

4 UB2 0.9 Specific service conditions coefficient for concrete (γb2)

5 DD1 16. Minimum diameter of longitudinal reinforcement bars for column

6 DD2 16. Maximum diameter of longitudinal reinforcement bars for column

7 BCL 15. Compression class of concrete

Page 542: International Design Codes

Concrete Design Per Russian Code Section 11A 11-8

No. Parameter

name Default value

Description

8 UBM 1. Product of service conditions coefficients for concrete, except UB2 (γb)

9 TEM 0. Parameter of concrete hardening conditions: • TEM=0, for natural hardening conditions; • TEM=1, for steam hardening conditions

10 CL1 0.05 Distance from edge of column cross section to the center of longitudinal reinforcement bar

11 ELY 1. Column's length coefficient to evaluate slenderness effect in local Y axis

12 ELZ 1. Column's length coefficient to evaluate slenderness effect in local Z axis

Тable 3 - Names of parameters for Concrete design according to Russian Code (SNiP 2.03.01-84*) for slabs and/or walls

No. Parameter

name Default value

Description

1 NLT 1 Number of long-term loading case

2 RCL 3

Class of longitudinal reinforcement: • RCL = 1, if class of reinforcement is A-I; • RCL = 2, if class of reinforcement is A-II; • RCL = 3, if class of reinforcement is A-III; • RCL = 33, if class of reinforcement is A-

IIIb; • RCL = 4, if class of reinforcement is A-IV; • RCL = 5, if class of reinforcement is A-V; • RCL = 6, if class of reinforcement is A-VI; • RCL = 7, if class of reinforcement is A-VII; • RCL = 77, if class of reinforcement is K-7; • RCL = 8, if class of reinforcement is B-II; • RCL = 9, if class of reinforcement is Bp-II; • RCL = 10, if class of reinforcement is Bp-I; • RCL = 19, if class of reinforcement is K-19

3 USM 1. Total product of service conditions coefficients for longitudinal reinforcement (γs)

4 UB2 0.9 Specific service conditions coefficient for

Page 543: International Design Codes

Section 11A 11-9

No. Parameter

name Default value

Description

concrete (γb2)

5 SDX 16. Diameter of reinforcing bars located in the first local (X) direction of slab/wall

6 SDY 16. Diameter of reinforcing bars located in the second local (Y) direction of slab/wall

7 BCL 15. Compression class of concrete

8 UBM 1. Product of service conditions coefficients for concrete, except UB2 (γb)

9 TEM 0. Parameter of concrete hardening conditions: • TEM=0, for natural hardening conditions; • TEM=1, for steam hardening conditions

10 CL 0.05

Distance from top/bottom face of slab/wall element to the center of longitudinal reinforcing bars located in first local (X) direction. (Main thickness of top/bottom concrete cover for slab/wall element)

11 CRA 0.05

Distance from top/bottom face of slab/wall element to the center of transverse reinforcing bars located in second local (Y) direction (Secondary thickness of top/bottom concrete cover for slab/wall)

12 WST 0.4 Ultimate width of short-term crack 13 WLT 0.3 Ultimate width of long-term crack

Parameter of limit state for slab/wall design: • STA=0, if calculation of nonsymmetrical

reinforcement must be carried out according to the requirements of load carrying capacity (the first limit state);

14 STA 0 • STA=1, if calculation of symmetrical

reinforcement must be carried out according to the requirements of load carrying capacity (the first limit state);

• STA=2, if calculation of nonsymmetrical reinforcement must be carried according to the cracking requirements (the second limit state);

Page 544: International Design Codes

Concrete Design Per Russian Code Section 11A 11-10

Parameter name

Default value

No. Description

• STA=3, if calculation of symmetrical reinforcement must be carried according to the cracking requirements (the second limit state)

15 SELX 0. Design length of wall member to evaluate slenderness effect in local X axis

16 SELY 0. Design length of wall member to evaluate slenderness effect in local Y axis

17 MMA 0

Design parameter of slab/wall reinforcement: • MMA=0, if reinforcement calculation must

be applied by stresses in local axis; • MMA=1, if reinforcement calculation must

be applied by principal stresses

18 MMB 1

Design parameter of slab/wall reinforcement: • MMB=0, if the effect of additional

eccentricity is not taken into account; • MMB=1, if the effect of additional

eccentricity is taken into account

11A.3 Beams

Reinforcement for beams of rectangular and T cross-section can be calculated. In calculation of longitudinal reinforcement bending moment about local axis Z and torsional moments are considered, but influence of longitudinal forces and bending moments in relation to local axis Y

loc

loc is ignored. In calculation of transverse reinforcement shear forces parallel to local axis Yloc and torsional moments are taken into account. Reinforcement for beams can be calculated either from conditions of strength or from conditions of open crack width limitation (see parameter SSE).

Page 545: International Design Codes

Section 11A 11-11

Parameters SFA and ЕFA are considered only in calculation of transverse reinforcement. In general case calculation of reinforcement for beams is carried out two times – according to strength conditions and according to conditions of open crack width limitation. In reinforcement calculations from conditions of strength design values of load have to be taken and in calculations from conditions of crack width limitation – characteristic (normative) load values are used. Both calculations can be carried out in one session with the use multiple analysis possibility of the program STAAD.Pro. In most cases calculation of reinforcement is carried out with account only of a part of loadings. In such cases command LOAD LIST is used, in which numbers of loads considered in calculation are indicated. Number of permanent and long-term loads equal to parameter NLT must be included into the list of considered loads. It has to be noted, that values of parameters DD1 and DD2 have influence not only on the width of opened crack but also in some cases, on design and normative reinforcement resistances. Parameter BCL can be equal to any value of concrete compression strength class given in SNiP 2.03.01−84* and to any intermediate value as well. It should be remembered, that accuracy of results of calculation of transverse reinforcement increases with the value of parameter NSE. Parameters SFA and ЕFA are considered only in calculations of transverse reinforcement. Beam 1 is shown in Figure 2 with rigid intervals the lengths of which are: at the start of the beam 0.3m and at the end – 0.2m. In modeling of the beam the following command can be used.

MEMBER OFFSET 1 START 0.3 0 0 1 END -0.2 0 0

Page 546: International Design Codes

Concrete Design Per Russian Code Section 11A 11-12

Figure 2 - Diagram of a beam with rigid intervals

When command MEMBER OFFSET is used forces correspond ng to the beam the length of

iwhich is equal to the distance between

is not used forces hich is equal to the

distcalcconsi and ЕFA=0,2 in rein In botbe tthe seco For

⇒ rces acting in bottom/top

to the centroid of longitudinal bars located at this edge;

points a and b are calculated and then used in calculation of reinforcement. In such case it is necessary to take into account default values of parameters SFA and ЕFA equal to zero. When command MEMBER OFFSET corresponding to the beam the length of w

ance between points 10 and 11 are calculated and then used in ulation of reinforcement. In this case it is necessary to

r values of parameters SFA=0.3 deforcement calculation.

h ment will he same. Calculated quantity of longitudinal reinforcement in

nd case will be greater.

cases calculated quantity of transverse reinforce

beam the following output is generated: ⇒ beam number; ⇒ method of calculation (according to conditions of strength

or limitations of opened crack width); ⇒ length and cross-sectional dimensions;

distance from resultant of foreinforcement to bottom/top edge of the section;

⇒ distance from the side edge of cross-section of the beam web

Page 547: International Design Codes

Section 11A 11-13

⇒ concrete c⇒ class of lo and transverse reinforcement;

assumed itransverse

⇒ calculatioreinforcem

In nine columnspresented:

As− area of longitudinal

e

longitudinal reinforcement in the top zone of cross-section of

e,

Moments (−/+) values of bending moments, determining cross-sectional areas of longitudinal reinforcement As− and As+ , kNm

Load. N. (−/+) numbers of loading versions, determining cross-sectional areas of longitudinal reinforcement

Acrc1 short-term opened crack width*, mm Acrc2 long-term opened crack width*, mm * Opened crack width is presented only in the case when calculation is performed according to conditions limiting opened crack width.

lass; ngitudinal

⇒ n calculations bar diameters of longitudinal and reinforcement; n results of longitudinal and transverse ent (in two tables).

of the first table the following results are

Section distance of the section from the “start” of the beam, мм cross-sectional reinforcement in the bottom zone of cross-section of the beam, if angle BETA=0°, or in thtop zone, if BETA=180° , sq.cm

As+ cross-sectional area of

the beam , if angle BETA=0°, or in the top zonif BETA=180° , sq.cm

Page 548: International Design Codes

Concrete Design Per Russian Code Section 11A 11-14

In ten columns of second table the following results are presented: Section distance of the section from the “start” of the

beam, mm Qsw intensity of transverse reinforcement, kN/m Asw cross-sectional area of transverse bars, sq.cm, if

their step is 10, 15, 20, 25 or 30 cm Q value of shear force parallel to the local axis, kN T value of torsional moment, kNm Load N. number of loading version, determining intensity

of transverse reinforcement An example of output of calculation results is presented below.

BEAM NO. 23 DESIGN RESULTS

(by limitation of crack width)

Length − 6000 mm. Section: BF1= 550 mm, B= 200 mm, HF1=220 mm, H=450 mm. Distance from top/bottom surface of beam to center of longitudinal reinforcement − 40 mm. Distance from side surface of beam to center of longitudinal reinforcement − 30 mm. Concrete class − В25.0 (Rb=13.05 MPa; Rbt=0.94 MPa; Gb2=0.9). Class of longitudinal reinforcement − А−III (Rs=365.0 MPa; Rsc=365.0 MPa). Diameter of longitudinal reinforcement bars D=16 mm. Class of shear reinforcement − А−I (Rsw=175.0 MPa). Diameter of shear reinforcement bars Dw=10 mm.

Page 549: International Design Codes

Section 11A 11-15

L O N G I T U D I N A L R E I N F O R C E M E N T

Section As- As+ Moments(-/+) Load.N.(-/+) Acrc1 Acrc2

mm sq.cm kNm mm mm 0.

10.92 0.41 −152. / 2. 6 / 4 0.237 0.121

500.

4.74 0.41 −60. / 0. 5 / 0 0.294 0.157

1000.

1.13 1.13 −5. / 17. 4 / 6 0.000 0.000

1500.

1.13 6.41 −8. / 75. 4 / 6 0.295 0.147

2000.

1.13 9.24 −11. / 115. 4 / 6 0.298 0.149

2500.

1.13 11.53 −14. / 139. 4 / 6 0.271 0.134

3000.

1.19 12.16 −18. / 144. 4 / 6 0.263 0.127

3500.

1.41 10.86 −21. / 132. 4 / 6 0.277 0.130

4000.

1.63 8.28 −24. / 103. 4 / 6 0.296 0.129

4500.

1.95 4.54 −27. / 56. 4 / 6 0.299 0.093

5000.

3.23 0.58 −39. / 9. 5 / 3 0.293 0.157

5500.

0.74 0.41 −124. / 0. 5 / 0 0.271 0.142

6000.

16.89 0.41 −226. / 0. 5 / 0 0.155 0.078

Page 550: International Design Codes

Concrete Design Per Russian Code Section 11A 11-16

S H E A R R E I N F O R C E M E N T

Section Qsw Asw, cm^2, if Sw= Q T Load mm kN/m 10cm 15cm 20cm 25cm 30cm kN kNm N.

0. 251.3 1.44 2.15 2.87 3.59 4.31 −203.9 0.0 6

500. 251.3 1.44 2.15 2.87 3.59 4.31 −168.9 0.0 6

1000. 174.5 1.00 1.50 1.99 2.49 2.99 −133.9 0.0 6

1500. 63.9 0.36 0.55 0.73 0.91 1.09 −98.9 0.0 6

2000. Minimum detailing requirements ! −63.9 0.0 6

2500. Minimum detailing requirements ! −28.9 0.0 6

3000. Minimum detailing requirements ! 12.7 0.0 5

3500. Minimum detailing requirements ! 47.7 0.0 5

4000. Minimum detailing requirements ! 82.7 0.0 5

4500. 95.0 0.55 0.82 1.09 1.37 1.64 117.7 0.0 5

5000. 242.5 1.39 2.08 2.77 3.46 4.16 152.7 0.0 5

5500. 302.5 1.73 2.59 3.46 4.32 5.19 187.7 0.0 5

6000. 302.5 1.73 2.59 3.46 4.32 5.19 216.1 0.0 5

Here Minimum detailing requirements! means that reinforcement is not required according to calculation.

11A.4 Columns

Reinforcement for columns of rectangular or circular cross-section can be calculated. Flexibility of columns can be evaluated in two ways. In the case of usual analysis (command PERFORM ANALYSIS) flexibility is assessed by parameters ELY and ELZ, values of which should conform with recommendation of the Code SNiP 2.03.01−84*. If P−DELTA (analysis according to deformed diagram) or NONLINEAR (nonlinear geometry) analysis is performed, values of parameters ELY and ELZ should be close to zero, for example ELY = ELZ=0.01. Longitudinal reinforcement for columns is calculated only from condition of strength. Longitudinal forces and bending moments in

Page 551: International Design Codes

Section 11A 11-17

relation to local axes Yloc and Zloc are taken into account in longitudinal reinforcement calculations.

⇒ quantity of longitudinal bars at each cross-section edge, directed parallel to the local axis ;

⇒ quantity of longitudinal bars at each cross-section edge, directed parallel to the local axis .

cross-sectional area of longitudinal reinforcement bars at each edge of section, directed parallel to the local axis , sq.cm cross-sectional area of longitudinal reinforcement bars at each edge of section, directed parallel to the local axis , sq.cm

respective values of longitudinal force and bending moments in relation to the local axes

and , determining cross-sectional area

For rectangular columns the following output is generated:

⇒ column number; ⇒ column length and cross-sectional dimensions; ⇒ distance of centroid of each longitudinal bar from the

nearest edge of the cross-section; ⇒ concrete class; ⇒ longitudinal reinforcement class; ⇒ range of longitudinal reinforcement bar diameters assumed

in calculation; ⇒ diameter of longitudinal reinforcement bars obtained in

calculation; ⇒ total quantity of longitudinal bars;

Yloc

Z loc In nine columns of the table under the heading LONGITUDINAL REINFORCEMENT the following output is presented: Section distance of the section from the “start” of the

column, mm Astot total cross-sectional area of longitudinal

reinforcement, sq.cm Asy

Yloc Asz

Z loc Percent reinforcement percentage in the section Nx, Mz, My

Z loc Yloc

Page 552: International Design Codes

Concrete Design Per Russian Code Section 11A 11-18

of longitudinal reinforcement

Number of longitudinal bars at each section edge parallel to the

Load.N. number of loading version, determining cross-sectional area of longitudinal reinforcement

An example of output of calculation results is presented below.

COLUMN NO. 97 DESIGN RESULTS

(rectangular section)

Length − 4000 mm. Section: B= 350 mm, H=350 mm. Distance from edge of column cross section to center of each longitudinal reinforcement bar − 40 mm. Concrete class − В25.0 (Rb=13.05 МPa; Gb2=0.9). Class of longitudinal reinforcement − А−III (Rs=365.0 МPa; Rsc=365.0 МPa). Diameter range of longitudinal reinforcement bars: Dmin=16 mm . . . Dmax=32 mm Diameter of longitudinal reinforcement bars from calculation d=20 mm. Total number of reinforcement bars Ntot=6. Number of longitudinal bars at each section edge parallel to the local Y axis Nyy =2.

local Z axis Nzz =3. L O N G I T U D I N A L R E I N F O R C E M E N T Section Astot Asy Asz Per cent Nx Mz My Load

m sq.cm sq.cm sq.cm % kN kNm kNm N.

0.

16.42

3.01

6.20

1.34

285.5

81.9

0.0

95.3

6

4000.

15.35

3.01

5.67

1.25

397.3

0.0

5

Page 553: International Design Codes

Section 11A 11-19

Diameter of longitudinal reinforcement bars, total quantity of longitudinal bars as well as quantity of longitudinal bars at each edge of the section obtained from calculation should be considered as recommendation. In this case arrangement of reinforcement in the section depends on the orientation of the local axes and is as follows: or

⇒ distance of centroid of each longitudinal bar to the edge of cross-section;

Calculated values of reinforcement cross-sectional areas are presented in the table and they may differ from recommended on the lower side.

When it is not possible according to detailing provisions to arrange in the column longitudinal reinforcement determined from calculation additional message is derived.

For columns of circular section the following output is generated:

⇒ column number; ⇒ column length and diameter of cross-section;

⇒ longitudinal reinforcement class; ⇒ assumed in calculation range of diameters of longitudinal

reinforcement bars; ⇒ diameter of longitudinal reinforcement bars obtained from

calculation; ⇒ quantity of longitudinal bars.

Page 554: International Design Codes

Concrete Design Per Russian Code Section 11A 11-20

In seven columns of the table under the heading LONGITUDINAL REINFORCEMENT the following results are presented: Section

Astot

percentage of longitudinal reinforcement Nx, Mz, My respective values of longitudinal force and

bending moments in relation to local axis and , determining cross-sectional area of longitudinal reinforcement

Class of longitudinal reinforcement − А−III (Rs=365.0 МPa; Rsc=365.0 МPa).

distance of the section from the “start” of the column, mm total cross-sectional area of longitudinal reinforcement, sq.cm

Per cent

Z loc Yloc

Load. N. number of loading version, determining cross-sectional area of longitudinal reinforcement

An example of output of calculation results for a column of circular section is presented below.

COLUMN NO. 80 DESIGN RESULTS

(circular section) Length − 4000 mm. Diameter: Dс= 350 mm. Distance from edge of column cross section to center of each longitudinal reinforcement bar − 50 mm. Concrete class − В20.0 (Rb=10.35 МPa; Gb2=0.9).

Diameter range of longitudinal reinforcement bars: Dmin=16 mm . . . Dmax=32 mm Diameter of longitudinal reinforcement bars from calculation D=20 mm. Total number of reinforcement bars Ntot =7.

Page 555: International Design Codes

Section 11A 11-21

L O N G I T U D I N A L R E I N F O R C E M E N T Section Astot Per cent Nx Mz My Load. N. mm sq.cm % kN kNm kNm 0. 17.96 1.87 195.1 59.8 4000. 2.27

Diameter of longitudinal reinforcement bars, total quantity of longitudinal bars as well as quantity of longitudinal bars at each edge of the section should be considered as recommendation.

0.0 5 21.86 195.1 80.2 0.0 5

Arrangement of reinforcement in section in this case is shown below:

Calculated cross-sectional areas of reinforcement presented in the table may differ from recommended on the lower side.

11A.5 2D (two dimensional) element (slabs, walls, shells)

When according to detailing provisions it is not possible to arrange in the column longitudinal reinforcement obtained from calculation additional message is derived.

In general case calculation of reinforcement for 2D members is carried out two times – according to conditions of strength and conditions of limiting opened width of cracks. If reinforcement is calculated according to conditions of strength, design values of loads have to be used, and for conditions of limiting crack width – characteristic (normative) loads are employed. Both calculations can be made in one session taking advantage of multiple analysis possibility of the program STAAD.Pro.

Page 556: International Design Codes

Concrete Design Per Russian Code Section 11A 11-22

Symmetric or nonsymmetric reinforcement of 2D members is calculated according to conditions of strength or according to conditions of limiting opened crack width (see for example STA). In reinforcement calculation for 2D members it is necessary to pay attention to arrangement of local axes of member and direction of reinforcement (see for example CL and CRA).

An exam

ple of o ted bellow. utput of calculation results is presen

SLAB/WALL DESIGN RESULTS (by stresses in local axes for limitation of crack width)

Element N. Asy N L .

s kN/m m m k (Y) Asx Mx Nx Load. My y oad N

q.cm/m kNm/m (X) sq.cm/ kNm/ N/m 60 TOP 0.00 - 4.9

- 9.9

0.0 1 0.00 - 4.5

- 8.9

0.0 1

3 BOT 3.53 0.0 3 3.46 0.0

61 TOP 0.00 - 5.3 0.0 1 1

BO 3.87 - 10.7 0.0 3 3.65 - 9.4 0.0 3

62 TOP 0.00 - 5.6 0.0 1 0.00 - 4.8 0.0 1

BOT 4.10 - 11.2 0.0 3 3.77 - 9.6 0.0 3

0.00 - 4.7 0.0

T

Page 557: International Design Codes

Section 11A 11-23

Here: Element number of finite element, TOP − “top” zone of

member, BOT − “bottom” zone of member (“top” zone of member is determined by positive direction of local axis − see Fig.2) intensity of reinforcing in the first direction (parallel to the local axis ), sq.cm/m distributed bending moment in respect to the local axis , kNm/m distributed longitudinal force directed parallel to the axis , kNm/m number of loading version, determining intensity of reinforcing in the first direction intensity of reinforcing in the second direction (parallel to the local axis ), sq.cm/m distributed bending moment in respect to the local axis kNm/m

Ny distributed longitudinal force directed parallel to the local axis kN/m number of loading version, determining intensity of reinforcing in the second direction

Z loc Asx

X locMx

Yloc Nx

X locLoad N.(X)

Asy Yloc

My X loc

YlocLoad N.(Y)

Page 558: International Design Codes

Concrete Design Per Russian Code Section 11A 11-24

Figure 2 - Local coordinate system of 2D member and notation of forces

Page 559: International Design Codes

11-25

Steel Design Per Russian Code SNIP 2.23-81* (EDITION 1990)

Section 11B

11B.1 General

Design Code SNiP “Steel Structures” as majority of modern codes is based on the method of limit states. The following groups of limit states are defined in the Code.

• The first group is concerned with losses of general shape and stability, failure, qualitative changes in configuration of structure. Appearance of non-allowable residual deformations, displacements, yielding of materials or opening of cracks.

• The second group is concerned with states of structures making worse normal their service or reducing durability due to not allowable deflections, deviations, settlements, vibrations, etc.

Analysis of structures for the first limit state is performed using the maximum (design) loads and actions, which can cause failure of structures. Analysis of structures for the second limit state is performed using service (normative) loads and actions. Relation between design and normative loads is refered to as coefficient of load reliability, which is defined in SNiP 2.01.07.- 85 “Loads and Actions”. Coefficient of reliability for destination GAMA n according to SNiP 2.01.07.- 85 shall be taken in to account determining loads or their combinations.

Page 560: International Design Codes

Steel Design Per Russian Code Section 11B 11-26

In this version of the program only members from rolled, tube and roll-formed assortment sections and also from compound such as double angles of T-type sections, double channels are presented. Design of other members of compound section will be presented in other versions of the program. Economy of selected section is indicated by ratio (RATIO) σ/Ryyc presented in calculation results. A section is economical when said ratio equals to 0,9 – 0,95.

11B.2 Axial tension members

Stress in a section of axial tension member shall not exceed design strength Ry of selected steel multiplied by coefficient of service conditions γc (KY and KZ), table 6 of SNiP 2.01.07.- 81*. Slenderness of tension member (CMM) shall not exceed slenderness limit indicated in table 20 of SNiP 2.01.07.- 81* (default value λu=200, but another value can be defined). Net section factor (ratio Anet/Agross (NSF)) is used for tension member to allow for reduction of design cross-section area.

11B.3 Axial compression members

All axial compression members are calculated as long bars, i.e., with allowance for slenderness (λ=l0/imin). Calculation is performed in accordance with the clause 5.3 of SNiP 2.01.07.- 81*, buckling coefficient ϕ is determined by formula 8-10. Effective bar lengths (within and out of plane) taking in to account role and location of the bar in the structure, as well as fixation of ends (l0=µl), are determined according to requirements of chapter 6 or addition 6 to SNiP 2.01.07.- 81* and are set by specification of members. Slenderness of compression members (CMN) shall not exceed limit values given in table 19 of SNiP 2.01.07.- 81*. Value of coefficient α being used in table 19 is taken within limits from 0,5 to 1,0. Limit slenderness value depends on stress acting in the member, section area, buckling coefficient and design resistance of steel.

Page 561: International Design Codes

Section 11B 11-27

Since slenderness can be different in various planes the greatest slenderness is assumed in calculations.

11B.4 Flexural members

Members subjected to the action of bending moments and shear forces are called flexural members. Calculation of flexural members consists of verification of strength, stability and deflection. Normal and tangential stresses are verified by strength calculation of members. Normal stresses are calculated in the outermost section fibres. Tangential stresses are verified in the neutral axis zone of the same section. If normal stresses do not exceed design steel strength and tangential stresses do not exceed design value of steel shear strength Rsγs then according to clause 5.14 of SNiP 2.01.07.- 81* principal stresses are checked. General stability of member subjected to bending in one plane are calculated in accordance with clause 5.15 of SNiP 2.01.07.- 81*, and subjected to bending in two planes – in accordance with “Guide to design of steel structures” (to SNiP 2.01.07.- 81*). Coefficient ϕb value is determined according to appendix 7 of SNiP 2.01.07.- 81*. Additional data about load (concentrated or distributed), numbers of bracing restrains of compression flanges, location of applied load are required. For closed sections it is assumed that coefficient ϕb=1,0. Simply supported (non-continuous) beams can be calculated in elastic as well as in elastic-plastic state according to requirements of clause 5.18 of SNiP 2.01.07.- 81*. Calculation can be selected by specification of structure in input data.

Page 562: International Design Codes

Steel Design Per Russian Code Section 11B 11-28

Stiffness of flexural members is verified comparing input value of deflection limit (through parameter DFF) with maximum displacement of a section of flexural member allowing for load reliability coefficient, which is specified, in input data. Limit values of deflection are determined in accordance with SNiP 2.01.07.- 85 “Loads and Actions. Addition chapter 10. Deflections and displacements”. Verification of deflection is performed only in the case of review (CHECK) problem.

11B.5 Eccentrical compression/tension members

Eccentrial compression or tension members are subjected to simultaneous action of axial force and bending moment. Bending moment appears due to eccentrical application of longitudinal force or due to transverse force. Stress in eccentrical compression/tension members is obtained as a sum of stresses due to axial force and bending. Following the requirements of clause 5.25 of SNiP 2.01.07.- 81* resistance of eccentrical compression/tension member taking into consideration condition Ry<530 MPa, τ<0,5Rs and N/(AnRy)>0,1 is calculated by formula 49, and in other cases-by formula 50. Calculations of stability verification are performed according to requirements of clauses 5.27, 5.30, 5.32 or 5.34.

Calculation for strength of eccentrial tension members is made according to formula 50 of SNiP 2.01.07.- 81*. When reduced relative eccentricity mef>20 eccentrical compression members are calculated as flexural members (N=0), when mef<20 strength by formula 49 is not verified (clause 5.24).

Page 563: International Design Codes

Section 11B 11-29

11B.6 Input Data

Program STAAD/Pro gives opportunity to verify sections of steel structures by codes of many countries including and Russian Code SNiP 2.01.07.- 81*. Algorithms for selection and review of sections for steel members according to assortments and databases of the main rolled steel producers from given countries and according to international standards as well are included in STAAD/Pro program. In this program version only assortment sections can be utilized. Typical sections of members being checked and selected according to SNiP 2.01.07.- 81* are presented in tables 1 and 2.

Table 1. Typical sections

No Section Section type Designation form

1 I-beam (GOST 8239-89) ST I12

2 Regular I-beam (GOST 26020-83) ST B1-10

3 Broad-flanged I-beam (GOST 26020-83) ST SH1-23

4 Column I-beam (GOST 26020-83)

ST K1-20

5

Channel (GOST 8240-89) ST C14

Page 564: International Design Codes

Steel Design Per Russian Code Section 11B 11-30

Table 1. Typical sections

No Section Section type Designation form

6 ST L100x100x7 Equal legs angle (GOST 8509-

89)

RA L100x100x7

7 Unequal legs angle (GOST 8510-89)

ST L125x80x10

RA L125x80x10

8 Pipes (welded and for gas piping)

ST PIP102x5.5 or

ST PIPE OD 0.102 ID 0.055

9 Roll-formed square and rectangular tubes

ST TUB160x120x3 or

ST TUBE TH 0.003 WT 0.12 DT 0.16

Page 565: International Design Codes

Section 11B 11-31

Table 2. Compound sections

No Section Section type Designation form

1 Double channels

D C14 SP 0.01 (SP – clear distance

between channel walls)

2 Double equal legs angles

LD L100x100x7 SP 0.01

(SP – clear distance between angle walls)

5 Double unequal legs angles with long legs back to back

LD L125x80x10 SP 0.01

(SP – clear distance between angle walls)

6 Double unequal legs angles with short legs back to back

SD L125x80x10 SP 0.01

(SP – clear distance between angle walls)

7 Tee with flange at the top

T I12 T B1-10

T SH1-23 T K1-20

Flange of Tee beams is at the top part of cross-section if angle BETA = 0°, or at the bottom part if BETA = 180°. For entry of cross-sectional dimensions command MEMBER PROPERTIES RUSSIAN is used.

Page 566: International Design Codes

Steel Design Per Russian Code Section 11B 11-32

Example: UNITS METER MEMBER PROPERTY RUSSIAN * I-beam 1 TO 6 TABLE ST B1-10 * Channel 7 TO 11 TABLE ST C14 * Unequal legs angle 12 TO 30 TABLE RA L125x80x10 * Round assortment pipe 31 TO 46 TABLE ST PIP102x5.5 * Round pipe of cross-sectional dimensions defined by client 47 TO 60 TABLE ST PIPE OD 0.102 ID 0.055 * Square tube from assortment 61 TO 68 TABLE ST TUB120x120x3 * Rectangular tube of cross-sectional dimension defined by client 69 TO 95 TABLE ST TUBE TH 0.003 WT 0.12 DT 0.16 * Double channel (distance between walls 10 мм) 96 TO 103 TABLE D C14 SP 0.01 * Double unequal legs angles with short legs back to back (distance between walls 10 мм) 104 TO 105 TABLE SD L125x80x10 SP 0.01 * Member of Tee section 106 TO 126 TABLE T SH1-23 * Flange of T-beams at the bottom of cross-section BETA 180. MEMB 116 TO 126 * Orientation of the local angle axes in relation to the global axes of the structure BETA RANGLE MEMB 12 TO 30 Commands of output data for check and selection of sections are located after commands of analysis and, as a rule, after output command to print results of calculation.

Page 567: International Design Codes

Section 11B 11-33

Example: * Command of analysis PERFORM ANALYSIS * Command of loadings and their combinations considered in design LOAD LIST 1 5 TO 9 * Command to start design according to Russian Code PARAMETER CODE RUSSIAN * List of parameters used in checking and selecting . BEAM 1. ALL (obligatory parameter) . LY 4. MEMB 1 TO 4 LZ 4. MEM 1 TO 4 MAIN 1. ALL SGR 3. ALL SBLT 0 ALL * Parameter of output amount of information on calculation results TRACK 2. ALL . * Command to start section check procedure CHECK CODE ALL * Command to start section selection procedure SELECT ALL . * Command of output to print content of assortment tables PRINT ENTIRE TABLE * Command of output to print summary of steel according to sections STEEL TAKE OFF * Command of output to print summary of steel according to members and sections STEEL MEMBER TAKE OFF

Page 568: International Design Codes

Steel Design Per Russian Code Section 11B 11-34

Information on parameters, data used for check and selection of sections in design of steel structures according to Russian Code is presented in table 3. In this version of calculation according to requirements of SNiP 2.01.07.- 81* there is common database of equal legs angles and unequal legs angles, therefore solution of section selection problem may give equal legs angle as well as unequal legs angle irrespective of set at the beginning. The same is and with rectangular and square tubes. Values of parameters do not depend on command UNIT. Only these values of parameters, which differ from, defined in the program need to be included in the input data file. Review of sections (command CHECK) can be performed according to the first and the second group of limit states. Selection of section (command SELECT) can be performed only according to the first group of limit states with subsequent recalculation and verification of selected section with allowance for deflection. Calculation for the first group of limit states involves selection of members according to strength and stability. Parameters CMN and CMM give opportunity to set slenderness limit for compression and tension members respectively for their stability calculation, or refuse consideration of slenderness by setting default parameters. In this case selection of sections will be performed with consideration only of strength check. Check for deflection performed by setting parameter DFF (maximum allowable relative deflection value) different from set in the program. In the case of application of steel not defined by SNiP and/or GOST it is necessary to set their design strength by parameters UNL and PY.

Page 569: International Design Codes

Section 11B 11-35

In determination of steel parameters SBLT and MAIN shall be approved (see table 4).

Table 3. Names of parameters for Steel design according to Russian Code (SNiP II – 23 – 81*, edition 1990)

No. Parameter

name Description

Default value

1 KY Coefficient of effective length in respect to local axis Y (in plane XZ)

1.0

2 KZ Coefficient of effective length in respect to local axis Z (in plane XY)

1.0

3 LY [m]

Effective length in respect to local axis Y (in plane XZ) Default is selected member's length

Member length

4 LZ [m]

Effective length in respect to local axis Z (in plane XY) Default is selected member's length

Member length

5 SBLT

Number of lateral bracing restraints along the span:

• SBLT = 0, if beam not fixed;

• SBLT = 1, one restraint in the middle of the span;

• SBLT = 2, 3, etc. number of uniformly spaced lateral supports along the span

0

6 NSF

Net section factor for tension members or web section area weakening factor for bending members

1.0

Page 570: International Design Codes

Steel Design Per Russian Code Section 11B 11-36

Table 3. Names of parameters for Steel design according to Russian Code (SNiP II – 23 – 81*, edition 1990)

No. Parameter

name Description

Default value

7 MAIN

Standard of steel grade (GOST): • MAIN = 1, if Standard of

steel grade is GOST27772-88;

• MAIN = 2, if Standard of steel grade is GOST10705-80;

• MAIN = 3, if Standard of steel grade is GOST10706-76;

1

• MAIN = 4, if Standard of steel grade is GOST8731-87;

• MAIN = 5, if Standard of steel grade is TY14-3-567-76

8 DFF

Allowable limit of relative local deflection (Member length/Deflection Ratio): Default value 0 is valid if design is applied without deflection limitation. Set for deflection check only

0.

Page 571: International Design Codes

Section 11B 11-37

Table 3. Names of parameters for Steel design according to Russian Code (SNiP II – 23 – 81*, edition 1990)

No. Parameter

name Description

Default value

9 SGR • SGR = 9, if Steel grade is C390;

• SGR = 13, if Steel grade is C590K;

• SGR = 17, if Steel grade is 20;

Steel grade (STAL): • SGR = 1, if Steel grade is

C235; • SGR = 2, if Steel grade is

C245; • SGR = 3, if Steel grade is

C255; • SGR = 4, if Steel grade is

C275; • SGR = 5, if Steel grade is

C285; • SGR = 6, if Steel grade is

C345; • SGR = 7, if Steel grade is

C345K; • SGR = 8, if Steel grade is

C375;

• SGR = 10, if Steel grade is C390K;

• SGR = 11, if Steel grade is C440;

• SGR = 12, if Steel grade is C590;

• SGR = 14, if Steel grade is BCT3KP;

• SGR = 15, if Steel grade is BCT3PC;

• SGR = 16, if Steel grade is BCT3CP;

1

Page 572: International Design Codes

Steel Design Per Russian Code Section 11B 11-38

Table 3. Names of parameters for Steel design according to Russian Code (SNiP II – 23 – 81*, edition 1990)

No. Parameter

name Description

Default value

• SGR = 18, if Steel grade is 16G2AF

10 СMM

Slenderness limit value for tension members:

• СMM = 0, if slenderness is suppressed;

• СMM = 2, if ultimate slenderness value is "150";

• СMM = 2, if ultimate slenderness value is "200";

• СMM = 3, if ultimate

0

Page 573: International Design Codes

Section 11B 11-39

Table 3. Names of parameters for Steel design according to Russian Code (SNiP II – 23 – 81*, edition 1990)

No. Parameter

name Description

Default value

slenderness value is "250";

• СMM = 5, if ultimate slenderness value is "350";

Set slenderness limit value not equal to "0" for design with evaluation of buckling effect

• СMM = 4, if ultimate slenderness value is "300";

• СMM = 6, if ultimate slenderness value is "400

11 CMN

Slenderness limit value for compression members:

• СMN = 0, if slenderness is suppressed;

• СMN = 1, if slenderness limit value is "120";

• СMN = 2, if slenderness limit value is "210-60a";

• СMN = 4, if slenderness limit

• СMN = 3, if slenderness limit value is "220-40a";

0

Page 574: International Design Codes

Steel Design Per Russian Code Section 11B 11-40

Table 3. Names of parameters for Steel design according to Russian Code (SNiP II – 23 – 81*, edition 1990)

No. Parameter

name Description

Default value

value is "220"; • СMN = 5, if

slenderness limit value is "180-60a";

• СMN = 6, if slenderness limit value is "210-60a";

• СMN = 7, if slenderness limit value is "210-60a";

• СMN = 8, if slenderness limit value is "200";

• СMN = 9, if slenderness limit value is "150";

Set slenderness limit value not equal to "0" for design with evaluation of buckling effect

12 LEG

Type and position of loading on beam:

• LEG = 1, for loading concentrated in the middle span;

• LEG = 2, for loading concentrated in the quarter of the span;

• LEG = 3, for loading concentrated at the end of bracket;

• LEG = 4, for loading uniformly distributed on

4

Page 575: International Design Codes

Section 11B 11-41

Table 3. Names of parameters for Steel design according to Russian Code (SNiP II – 23 – 81*, edition 1990)

No. Parameter

name Description

Default value

beam; • LEG = 5, for loading

uniformly distributed on bracket

13 CB

Place of loading on beam: • CB = 1, for loading on

top flange; 1 • CB = 2, for loading on

bottom flange

14 TRACK

Output parameter: • TRACK = 0, for

suppressed output information;

• TRACK = 1, for extended output information;

0

• TRACK = 2, for advanced output information

15

Indication of elastic or elastic-plastic calculation:

• TB = 1, for elastic-plastic calculation

• TB = 0, for elastic calculation

TB

Set for members under bending or non-axial compression/tension only.

0

16 RATIO Ratio between design and characteristic loads values

1.0

Page 576: International Design Codes

Steel Design Per Russian Code Section 11B 11-42

Table 3. Names of parameters for Steel design according to Russian Code (SNiP II – 23 – 81*, edition 1990)

No. Parameter

name Description

Default value

17 DMAX

[m] 1. Maximum allowable section depth

18 DMIN

[m] Minimum allowable section depth 0.

19 BEAM

Member design parameter: • BEAM = 0, Design

members for forces at their ends or at the sections defined by SECTION command;

• BEAM = 1, Calculate the major axis moment Mz at 13 points along the beam and design beam at the location of maximum Mz;

• BEAM = 2, Same as BEAM=1, but additional checks are carried out at beam ends and at critical inter mediate section;

• BEAM = 3, Calculate forces at 13 points and perform design checks at all locations including the ends

1

20 GAMC1 Specific service condition coefficient for buckling design

1.0

21 GAMC2 Specific service condition coefficient for strength design

1.0

22 PY

[MPa]

Design steel strength (yield strength):

0 If parameters MAIN according to Standard of steel grade (GOST)

Page 577: International Design Codes

Section 11B 11-43

Table 3. Names of parameters for Steel design according to Russian Code (SNiP II – 23 – 81*, edition 1990)

No. Parameter

name Description

Default value

and by SGR according to Steel grade (STAL) are not defined

23 UNL

[MPa]

Design steel strength (ultimate strength): If parameters MAIN according to Standard of steel grade (GOST) and by SGR according to Steel grade (STAL) are not defined

0

Page 578: International Design Codes

Steel Design Per Russian Code Section 11B 11-44

Table 4. Steel types for design of steel structures according to SNiP 2.01.07.- 81* (table 51 and 51a) Parameter

SGR Steel

Parameter MAIN

GOST For members

*

1 C235 1 GOST GT, F

2 C245 1 “ GT, F

3 C255 1 “ GT, F

4 C275 1 “ GT, F

5 C285 1 “ GT, F

6 C345 1 “ GT, F

7 C345K 1 “ GT, F

8 C375 1 “ GT, F

9 C390 1 “ F

10 C390K 1 “ F

11 C440 1 “ F

12 C590 1 “ F

13 C590К 1 “ F

14 BSt3kp 2 GOST Tube

15 BSt3ps 2 3

GOST 10705-

80*Tube

16 BSt3sp 2 3

GOST 10705-

80*Tube

17 20 4 GOST Tube

18 16G2АF 5 TY 14-3- Tube *GT – members from sheet and roll-formed tubes F – rolled section steel

Page 579: International Design Codes

Section 11B 11-45

11B.7 Section selection and check results

Output of selection and check results are given in suppressed, extended and advanced forms. Form of output results depends on value of parameter TRACK. Results are presented in tables. Three versions of output results are possible: suppressed – results according the critical strength condition (TRACK=0), extended - results according to all check conditions (TRACK=1) and advanced – complete information on results of member design (TRACK=2). In tables of results common data for all TRACKs are indicated: (TRACK=2).

In tables of results common data for all TRACKs are indicated:

number of member; type and number of cross-section;

result obtained (ACCEPTED – requirements are met, FAILURE – are not met); abbreviated name of normative document (code, standard) (SNiP); number of check clause; safety of strength (ratio between design and normative values); number of the most unfavorable loading; value of longitudinal force acting in the member with subscript indicating its direction (“C” – compression, “P” – tension); bending moments in relation to local member axes Z and Y; distance to section, in which the most unfavorable combination of forces acts.

Page 580: International Design Codes

Steel Design Per Russian Code Section 11B 11-46

In suppressed form (TRACK=0) results are presented according to the critical check for given member with indication of SNiP clause number, according to which strength safety of the member is minimum. Example of output with TRACK=0 of calculation results of a member is given below.

ALL UNITS ARE - KN METE ============================================================== MEMBER CROSS RESULT/ CRITICAL COND/ RATIO/ LOADING/ SECTION NO. FX MZ MY LOCATION ============================================================== 1 B1-30 PASS SNiP- 5.12 0.73 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00

In extended form (TRACK=1) results are presented on the basis of all required by SNiP checks for given stress state.

Example of output with TRACK=1 of calculation results of a member is given below.

ALL UNITS ARE - KN METE ============================================================== MEMBER CROSS RESULT/ CRITICAL COND/ RATIO/ LOADING/ SECTION NO. FX MZ MY LOCATION ============================================================== 1 B1-30 PASS SNiP- 5.12 0.73 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00 1 B1-30 PASS SNiP- 5.12 0.06 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00 1 B1-30 PASS SNiP- 5.14 0.97 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00 1 B1-30 PASS SNiP- 5.15 0.84 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00 * 1 B1-30 FAIL SNiP- DISPL 1.59 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00

Page 581: International Design Codes

Section 11B 11-47

In advanced form (TRACK=2) in addition to tabled results supplementary information is presented. Material characteristics: Steel; Design resistance; Elasticity modulus; Section characteristics: Length of member; Section area; Net area; Inertia moment (second moment of area) (I); Section modulus (W); First moment of area (S);

Results are presented in two columns, Z and Y respectively.

Radius of gyration; Effective length; Slenderness;

Design forces: Longitudinal force; Moments; Shear force. Signs “+” and “-“ indicate direction of acting longitudinal force, bending moments and shear forces in accordance with sign rules assumed in program STAAD. Check results in advanced form are presented with values of intermediate parameters by formulas in analytical and numerical expression with indication of SNiP clause. Example of output with TRACK=2 of calculation results of a member is given in the next page.

Page 582: International Design Codes

Steel Design Per Russian Code Section 11B 11-48

ALL UNITS ARE - KN METE ======================================================================== MEMBER CROSS RESULT/ CRITICAL COND/ RATIO/ LOADING/ SECTION NO. FX MZ MY LOCATION ======================================================================== 1 B1-30 PASS SNiP- 5.12 0.73 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00 1 B1-30 PASS SNiP- 5.12 0.06 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00 1 B1-30 PASS SNiP- 5.14 0.97 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00 1 B1-30 PASS SNiP- 5.15 0.84 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00 * 1 B1-30 FAIL SNiP- DISPL 1.59 2 0.000E+00 -8.750E+01 0.000E+00 4.167E+00 MATERIAL DATA Steel = C285 Modulus of elasticity = 206.E+06 KPA Design Strength (Ry) = 280.E+03 KPA SECTION PROPERTIES (units - m) Member Length = 1.00E+01 Gross Area = 4.19E-03 Net Area = 4.19E-03 z-axis y-axis Moment of inertia (I) : 633.E-07 390.E-08 Section modulus (W) : 428.E-06 557.E-07 First moment of area (S) : 240.E-06 415.E-07 Radius of gyration (i) : 123.E-03 305.E-04 Effective Length : 100.E-01 333.E-02 Slenderness : 0.00E+00 0.00E+00 DESIGN DATA (units -kN,m)SNiP II-23-81*/1998 Axial force : 0.00E+00 z-axis y-axis Moments : -875.E-01 0.00E+00 Shear force : 0.00E+00 -150.E-01 CRITICAL CONDITIONS FOR EACH CLAUSE CHECK F.(28) M/Wmin=-875.0E-01/ 4.28E-04= 204.6E+03 F.(29) (QY*SZ)/(IZ*TW)=-150.0E-01* 2.40E-04/ 6.33E-05* 5.80E-03= 980.9E+01 RS*GAMAC= 162.4E+03 F.(33) SQRT(SIGMz**2+3*TAUzy**2)<=1.15*RY*GAMAC -312.5E+03**2+3* 980.9E+01**2<=1.15* 280.0E+03* 100.0E-02 313.0E+03<= 322.0E+03 TAUzy<=RS*GAMAC 980.9E+01<= 162.4E+03 F.(34) M/(FIB*Wmin)=-875.0E-01/ 8.75E-01* 4.28E-04= 234.0E+03 RY*GAMAC= 280.0E+03 ACTUAL SECTION DISPLACEMENT = 6.349E-02 M MAXIMUM MEMBER DEFLECTION = 6.349E-02 M Loading No. 2 ULTIMATE ALLOWABLE DEFLECTION VALUE = 4.000E-02 M

Conventional notations assumed in presentation of results: “+”, “-“, “/”, “*”,”**”, “SQRT”, their respective meanings – addition, subtraction, division, multiplication, raising to the second power (squared) and square root. Conventional notations of stresses, coefficients and characteristics of steel resistance comply with accepted in SNiP, only Greek letters are changed by their names (e.g. , γс-GAMAC; α-ALFA; β-BETA, η-ETA, ϕ-FI, etc.).

Page 583: International Design Codes

Section 12 South African

Codes

Page 584: International Design Codes
Page 585: International Design Codes

12-1

Concrete Design Per SABS 0100-1

12A.1 Design Operations

The program contains a number of parameters which are needed to perform and control the design to SABS 0100-1. These parameters not only act as a method to input required data for code calculations but give the engineer control over the actual design process. Default values of commonly used parameters for conventional design practice have been chosen as the basis. Table 12A.1 contains a complete list of available parameters with their default values.

Section 12A

STAAD has the capability for performing design of concrete beams and columns according to the South African code SABS 0100-1. The 2000 revision of the code is currently implemented. Design can be performed for beams (flexure, shear and torsion) and columns (axial load + biaxial bending). Given the width and depth (or diameter for circular columns) of a section, STAAD will calculate the required reinforcement.

12A.2 Design Parameters

Page 586: International Design Codes

South African Concrete Code Per SABS 0100-1 Section 12A 12-2

Table 12A.1 – South African Concrete Design-SABS 0100-1 -Parameters Parameter Default Description Name FYM

Value AIN *450 N/mm2 Yield Stress for main reinforcement

FYSEC *450N/mm2 Yield Stress for secondary reinforcement a. Applicable to shear bars in beams

FC * 30N/mm2 Concrete Yield Stress / cube strength MINMAIN 8mm Minimum main reinforcement bar size

Acceptable bar sizes: 6 8 10 12 16 20 25 2832 36 40 50 60

MINSEC 8mm Minimum secondary bar size a. Applicable to shear reinforcement in beams

MAXMAIN 50mm Maximum required reinforcement bar sizeAcceptable bars are per MINMAIN above.

CLT 20mm Clear Cover for outermost top reinforcement CLB 20mm Clear Cover for outermost bottom

reinforcement CLS 20mm Clear Cover for outermost side

reinforcement TRACK 0.0 0.0 = Critical Moment will not be printed with

beam design report. Column design gives nodetailed results. 1.0 = For beam gives min/max steel % and spacing. For columns gives a detailed tableof output with additional moments calculated. 2.0 = Output of TRACK 1.0List of design sag/hog moments andcorresponding required steel area at eachsection of member

WIDTH *ZD Width of concrete member. This value default is as provided as ZD in MEMBER PROPERTIES.

DEPTH *YD Depth of concrete member. This value default is as provided as YD in MEMBER PROPERTIES.

Page 587: International Design Codes

Section 12A 12-3

Table 12A.1 – South African Concrete Design-SABS 0100-1 -Parameters Parameter Default Description Name Value BRACE 0.0 0.0 = Column braced in both directions.

1.0 = Column braced about local Y direction only 2.0 = Column unbraced about local Z direction only 3.0 = Column unbraced in both Y and Z directions

ELY 1.0 Member length factor about local Y direction for column design.

ELZ 1.0 Member length factor about local Z direction for column design.

* Provided in current unit system

12A.3 Member Dimensions

Concrete members that are to be designed by STAAD must have certain section properties input under the MEMBER PROPERTIES command. The following example demonstrates the required input:

UNIT MM MEMBER PROPERTIES *RECTANGULAR COLUMN 300mm WIDE X 450mm DEEP 1 3 TO 7 9 PRISM YD 450. ZD 300. *CIRCULAR COLUMN 300mm diameter 11 13 PR YD 300. * T-SECTION - FLANGE 1000.X 200.(YD-YB) * - STEM 250(THICK) X 350.(DEEP) 14 PRISM YD 550. ZD 1000. YB 350. ZB 250.

Page 588: International Design Codes

South African Concrete Code Per SABS 0100-1 Section 12A 12-4

In the above input, the first set of members are rectangular (450mm depth x 300mm width) and the second set of members, with only depth and no width provided, will be assumed to be circular with 300mm diameter. Note that area (AX) is not provided for these members. If shear area areas ( AY & AZ ) are to be considered in analysis, the user may provide them along with YD and ZD. Also note that if moments of inertias are not provided, the program will calculate them from YD and ZD. Finally a T section can be considered by using the third definition above.

12A.4 Beam Design

Beam design includes flexure, shear and torsion. For all types of beam action, all active beam loadings are scanned to create moment and shear envelopes and locate the critical sections. The total number of sections considered is thirteen. From the critical moment values, the required positive and negative bar pattern is developed. Design for flexure is carried out as per clause no. 4.3.3.4.

Shear design as per SABS 0100 clause 4.3.4 has been followed and the procedure includes computation of critical shear values. From these values, stirrup sizes are calculated with proper spacing. If torsion is present, the program will also consider the provisions of SABS 0100 clause 4.3.5. Torsional reinforcement is separately reported.

Page 589: International Design Codes

Section 12A 12-5

A TRACK 2 design output is presented below. B E A M N O. 4 D E S I G N R E S U L T S M20 Fe450 (Main) Fe450 (Sec.) LENGTH: 7500.0 mm SIZE: 380.0 mm X 715.0 mm COVER: 25.0 mm DESIGN LOAD SUMMARY (KN MET) -------------------------------------------------------------------- SECTION |FLEXURE (Maxm. Sagging/Hogging moments)| SHEAR (in mm) | MZ Load Case MX Load Case | VY P Load Case -------------------------------------------------------------------- 0.0 | 135.75 5 -3.44 5 | 152.06 50.62 4 | -295.92 4 | 625.0 | 189.16 5 -3.43 5 | 133.95 48.87 4 | -236.52 4 | 1250.0 | 231.25 5 -3.41 5 | 115.84 47.12 4 | -188.44 4 | 1875.0 | 262.01 5 -3.40 5 | 97.73 45.37 4 | -151.68 4 | 2500.0 | 281.46 5 -3.39 5 | 79.61 43.63 4 | -126.24 4 | 3125.0 | 289.59 5 -3.37 5 | 61.50 41.88 4 | -112.12 4 | 3750.0 | 286.39 5 -3.36 4 | -62.13 40.13 5 | -109.32 4 | 4375.0 | 271.88 5 -3.37 4 | -80.25 41.88 5 | -117.84 4 | 5000.0 | 246.05 5 -3.39 4 | -98.36 43.63 5 | -137.68 4 | 5625.0 | 208.89 5 -3.40 4 | -116.47 45.37 5 | -168.84 4 | 6250.0 | 160.42 5 -3.41 4 | -134.58 47.12 5 | -211.33 4 | 6875.0 | 100.62 5 -3.43 4 | -152.70 48.87 5 | -265.13 4 | 7500.0 | 29.50 4 -3.44 4 | -170.81 29.63 4 | -330.25 5 | SUMMARY OF REINF. AREA FOR FLEXURE DESIGN (Sq.mm) -------------------------------------------------------------------- SECTION | TOP | BOTTOM | STIRRUPS (in mm) | Reqd./Provided reinf. | Reqd./Provided reinf. | (2 legged) -------------------------------------------------------------------- 0.0 | 1232.70/1256.64( 4-20í )| 543.40/ 565.50( 5-12í )| 8í @ 425 mm 625.0 | 960.90/ 981.74( 2-25í )| 754.32/ 791.70( 7-12í )| 8í @ 510 mm 1250.0 | 751.24/ 791.70( 7-12í )| 937.49/ 942.48( 3-20í )| 8í @ 510 mm 1875.0 | 596.52/ 603.18( 3-16í )| 1075.72/1206.36( 6-16í )| 8í @ 510 mm 2500.0 | 543.40/ 565.50( 5-12í )| 1165.13/1206.36( 6-16í )| 8í @ 510 mm 3125.0 | 543.40/ 565.50( 5-12í )| 1203.00/1206.36( 6-16í )| 8í @ 220 mm 3750.0 | 543.40/ 565.50( 5-12í )| 1188.08/1206.36( 6-16í )| 8í @ 220 mm 4375.0 | 543.40/ 565.50( 5-12í )| 1120.87/1206.36( 6-16í )| 8í @ 220 mm 5000.0 | 543.40/ 565.50( 5-12í )| 1003.50/1005.30( 5-16í )| 8í @ 220 mm 5625.0 | 668.18/ 678.60( 6-12í )| 839.38/ 904.80( 8-12í )| 8í @ 220 mm 6250.0 | 849.99/ 904.80( 8-12í )| 632.84/ 678.60( 6-12í )| 8í @ 220 mm 6875.0 | 1089.94/1206.36( 6-16í )| 543.40/ 565.50( 5-12í )| 8í @ 220 mm 7500.0 | 1397.16/1407.42( 7-16í )| 543.40/ 565.50( 5-12í )| 8í @ 220 mm -------------------------------------------------------------------- TORSION REINFORCEMENT: Not required

Page 590: International Design Codes

South African Concrete Code Per SABS 0100-1 Section 12A 12-6

12A.5 Column Design

Columns are designed for axial force and biaxial bending at the ends. All active loadings are tested to calculate reinforcement. The loading which produces maximum reinforcement is called the critical load and is displayed. The requirements of SABS 0100-1 clause 4.7 are followed, with the user having control on the effective length in each direction by using the ELZ and ELY parameters as described in table 12A.1. Bracing conditions are controlled by using the BRACE parameter. The program will then decide whether or not the column is short or slender and whether it requires additional moment calculations. For biaxial bending, the recommendations of 4.7.4.4 of the code are considered.

Column design is done for square, rectangular and circular sections. For rectangular and square sections, the reinforcement is always assumed to be arranged symmetrically. This causes slightly conservative results in certain cases. Table 12A.3 shows typical column design results.

Using parameter TRACK 1.0, the detailed output below is obtained. TRACK 0.0 would merely give the bar configuration, required steel area and percentage, column size and critical load case.

Page 591: International Design Codes

Section 12A 12-7

TABLE 12A.3 -COLUMN DESIGN OUTPUT ======================================================================= C O L U M N N O. 1 D E S I G N R E S U L T S M20 Fe450 (Main) Fe450 (Sec.) LENGTH: 3660.0 mm CROSS SECTION: 750.0 mm X 460.0 mm COVER:40.0mm ** GUIDING LOAD CASE: 4 END JOINT: 1 SHORT COLUMN DESIGN FORCES (KNS-MET) ----------------------- DESIGN AXIAL FORCE (Pu) : 915.6 About Z About Y INITIAL MOMENTS : 0.00 0.00 MOMENTS DUE TO MINIMUM ECC. : 18.31 18.31 SLENDERNESS RATIOS : 7.96 4.88 ADDITION MOMENTS (Maddz and Maddy) : 0.00 0.00 TOTAL DESIGN MOMENTS : 555.13 21.91 REQD. STEEL AREA : 3349.20 Sq.mm. REQD. CONCRETE AREA: 114451.62 Sq.mm. MAIN REINFORCEMENT : Provide 32 - 12 dia. (1.05%, 3619.20 Sq.mm.) (Equally Distributed) TIE REINFORCEMENT : Provide 8 mm dia. rectangular ties @ 140 mm c/c SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS-MET) ---------------------------------------------------------- Puz : 2160.42 Muz1 : 570.23 Muy1 : 563.74

Page 592: International Design Codes

South African Concrete Code Per SABS 0100-1 Section 12A 12-8

Page 593: International Design Codes

12-9

Steel Design Per SAB Standard SAB0162–1: 1993

Section 12B

12B.1 General

The South African Steel Design facility in STAAD is based on the SAB Standard SAB0162-1: 1993, Limit States Design of Steel Structures. A steel section library consisting of South African Standards shapes is available for member property specification. The design philosophy embodied in this specification is based on the concept of limit state design. Structures are designed and proportioned taking into consideration the limit states at which they would become unfit for their intended use. Two major categories of limit-state are recognized - ultimate and serviceability. The primary considerations in ultimate limit state design are strength and stability, while that in serviceability is deflection. Appropriate load and resistance factors are used so that a uniform reliability is achieved for all steel structures under various loading conditions and at the same time the chances of limits being surpassed are acceptably remote. In the STAAD implementation, members are proportioned to resist the design loads without exceeding the limit states of strength, stability and serviceability. Accordingly, the most economic section is selected on the basis of the least weight criteria as augmented by the designer in specification of allowable member depths, desired section type, or other such parameters. The code checking portion of the program checks whether code requirements for each selected section are met and identifies the governing criteria.

Page 594: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-10

The following sections describe the salient features of the STAAD implementation of SAB0162-1: 1993. A detailed description of the design process along with its underlying concepts and assumptions is available in the specification document.

12B.2 Analysis Methodology

Elastic analysis method is used to obtain the forces and moments for design. Analysis is done for the primary and combination loading conditions provided by the user. The user is allowed complete flexibility in providing loading specifications and using appropriate load factors to create necessary loading situations. Depending upon the analysis requirements, regular stiffness analysis or P-Delta analysis may be specified. Dynamic analysis may also be performed and the results combined with static analysis results.

12B.3 Member Property Specifications

The following information is provided for use when the built-in steel tables are to be referenced for member property specification. These properties are stored in a database file. If called for, the properties are also used for member design. Since the shear areas are built into these tables, shear deformation is always considered during the analysis of these members.

For specification of member properties, the steel section library available in STAAD may be used. The next section describes the syntax of commands used to assign properties from the built-in steel table. Member properties may also be specified using the User Table facility. For more information on these facilities, refer to the STAAD Technical Reference Manual.

12B.4 Built-in Steel Section Library

Page 595: International Design Codes

Section 12B 12-11

I Shapes The following example illustrates the specification of I- shapes.

1 TO 15 TABLE ST IPE-AA100

H shapes Designation of H shapes in STAAD is as follows. For example,

18 TO 20 TABLE ST 152X37UC

PG shapes Designation of PG shapes in STAAD is as follows.

100 TO 150 TABLE ST 720X200PG

Channel Sections (C & MC shapes) C and MC shapes are designated as shown in the following example.

3 TABLE ST 127X64X15C

Double Channels Back to back double channels, with or without spacing between them, are specified by preceding the section designation by the letter D. For example, a back to back double channel section PFC140X60 without spacing in between should be specified as:

Page 596: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-12

100 TO 150 TABLE D PFC140X60

A back to back double channel section 140X60X16C with spacing 0.01unitlength in between should be specified as:

100 TO 150 TABLE D 140X60X16C SP 0.01

Note that the specification SP after the section designation is used for providing the spacing. The spacing should always be provided in the current length unit. Angles To specify angles, the letter L succeeds the angle name. Thus, a 70X70 angle with a 25mm thickness is designated as 70X70X8L. The following examples illustrate angle specifications.

100 TO 150 TABLE ST 70X70X8L

Note that the above specification is for “standard” angles. In this specification, the local z-axis (see Fig. 2.6 in the Technical Reference Manual) corresponds to the Y’-Y’ axis shown in the CSA table. Another common practice of specifying angles assumes the local y-axis to correspond to the Y’-Y’ axis. To specify angles in accordance with this convention, the reverse angle designation facility has been provided. A reverse angle may be specified by substituting the word ST with the word RA. Refer to the following example for details.

100 TO 150 TABLE RA 45X45X3L

The local axis systems for STANDARD and REVERSE angles is shown in Fig. 2.6 of the STAAD Technical Reference manual.

Page 597: International Design Codes

Section 12B 12-13

Double Angles To specify double angles, the specification ST should be substituted with LD (for long leg back to back) or SD (short leg back to back). For equal angles, either SD or LD will serve the purpose. Spacing between angles may be provided by using the word SP followed by the value of spacing (in current length unit) after section designation.

100 TO 150 TABLE LD 50X50X3L 3 TABLE LD 40X40X5L SP 0.01

The second example above describes a double angle section consisting of 40X40X5 angles with a spacing of 0.01 length units. Tees Tee sections obtained by cutting W sections may be specified by using the T specification instead of ST before the name of the W shape. For example:

100 TO 150 TABLE T IPE-AA180

will describe a T section cut from a IPE-AA180 section. Rectangular Hollow Sections These sections may be specified in two possible ways. Those sections listed in the SAB tables may be specified as follows.

100 TO 150 TABLE ST TUB60X30X2.5

Page 598: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-14

Width

Tube symbol

Height

Thickness

TUB60X30X2.5

In addition, any tube section may be specified by using the DT(for depth), WT(for width), and TH(for thickness) specifications. For example:

100 TO 150 TABLE ST TUBE TH 3 WT 100 DT 50

will describe a tube with a depth of 50mm, width of 100mm. and a wall thickness of 3mm. Note that the values of depth, width and thickness must be provided in current length unit.

Circular Hollow Sections Sections listed in the SAB tables may be provided as follows:

100 TO 150 TABLE ST PIP34X3.0CHS

In addition to sections listed in the SAB tables, circular hollow sections may be specified by using the OD (outside diameter) and ID (inside diameter) specifications.

Pipe symbol Thickness

PIP34X3.0

Diameter

Page 599: International Design Codes

Section 12B 12-15

For example:

100 TO 150 TABLE ST PIPE OD 50 ID 48

will describe a pipe with an outside diameter of 50 length units and inside diameter of 48 length units. Note that the values of outside and inside diameters must be provided in terms of current length unit. Sample input file to demonstrate usage of South African shapes is shown below. STAAD PLANE START JOB INFORMATION ENGINEER DATE 30-Mar-05 END JOB INFORMATION UNIT METER KN JOINT COORDINATES 1 0 0 0; 2 9 0 0; 3 0 6 0; 4 3 6 0; 5 6 6 0; 6 9 6 0; 7 0 10.5 0; 8 9 10.5 0; 9 2.25 10.5 0; 10 6.75 10.5 0; 11 4.5 10.5 0; 12 1.5 11.4 0; 13 7.5 11.4 0; 14 3 12.3 0; 15 6 12.3 0; 16 4.5 13.2 0; MEMBER INCIDENCES 1 1 3; 2 3 7; 3 2 6; 4 6 8; 5 3 4; 6 4 5; 7 5 6; 8 7 12; 9 12 14; 10 14 16; 11 15 16; 12 13 15; 13 8 13; 14 9 12; 15 9 14; 16 11 14; 17 11 15; 18 10 15; 19 10 13; 20 7 9; 21 9 11; 22 10 11; 23 8 10; MEMBER PROPERTY SAFRICAN 1 TABLE ST IPE-AA100 2 TABLE T IPE120 3 TABLE ST 152X23UC 4 TABLE T 152X23UC 5 TABLE ST 812X200PG 6 TABLE T 812X200PG 7 TABLE ST 178X54X15C 8 TABLE D 178X54X15C 9 TABLE D 178X54X15C SP 0.1 10 TABLE ST 25X25X5L 11 TABLE RA 25X25X5L 12 TABLE LD 25X25X5L 13 TABLE SD 25X25X5L 14 TABLE LD 25X25X5L SP 0.1 15 TABLE SD 25X25X5L SP 0.1

Page 600: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-16

16 TABLE ST TUB40X2.5SHS 17 TABLE ST TUBE TH 0 WT 0 DT 50 18 TABLE ST TUBE TH 0.02 WT 100 DT 50 20 TABLE ST PIP48X2.0CHS 21 TABLE ST PIPE OD 0.5 ID 0.48 PRINT MEMBER PROPERTIES FINISH

12B.5 Section Classiication

The SAB specification allows inelastic deformation of section elements. Thus, local buckling becomes an important criterion. Steel sections are classified as plastic (Class 1), compact (Class 2), non compact (Class 3) or slender element (Class 4) sections depending upon their local buckling characteristics (See Clause 11.2 and Table 1 of SAB0162-1:1993). This classification is a function of the geometric properties of the section. The design procedures are different depending on the section class. STAAD determines the section classification for the standard shapes and user specified shapes. Design is performed for sections that fall into the category of Class 1,2 or 3 sections only. Class 4 sections are not designed by STAAD.

12B.6 Member Resistances

The member resistances are calculated in STAAD according to the procedures outlined in section 13 of the specification. These depend on several factors such as members unsupported lengths, cross-sectional properties, slenderness factors, unsupported width to thickness ratios and so on. Note that the program automatically takes into consideration appropriate resistance factors to calculate member resistances. Explained here is the procedure adopted in STAAD for calculating the member resistances. All the members are checked against allowable slenderness ratio as per Cl.10.2 of SAB0162-1: 1993.

Page 601: International Design Codes

Section 12B 12-17

Axial Tension The criteria governing the capacity of tension members is based on two limit states. The limit state of yielding in the gross section is intended to prevent excessive elongation of the member. The second limit state involves fracture at the section with the minimum effective net area. The net section area may be specified by the user through the use of the parameter NSF (see Table 3B.1). STAAD calculates the tension capacity of a member based on these two limits states per Cl.13.2 of SAB0162-1: 1993. Parameters FYLD, FU and NSF are applicable for these calculations. Axial Compression

2. For single angles, asymmetric or cruciform sections are checked as to whether torsional-flexural buckling is critical. But for KL/r ratio exceeding 50,as torsional flexural buckling is not critical, the axial compression capacities are calculated by using Cl.13.3. The reason for this is that the South African code doesn’t provide any clear guidelines for calculating this value. The parameters KY, LY, KZ and LZ are applicable for this.

The compressive resistance of columns is determined based on Clause 13.3 of the code. The equations presented in this section of the code assume that the compressive resistance is a function of the compressive strength of the gross section (Gross section Area times the Yield Strength) as well as the slenderness factor (KL/r ratios). The effective length for the calculation of compression resistance may be provided through the use of the parameters KX, KY, KZ, LX, LY and LZ (see Table 3B.1). Some of the aspects of the axial compression capacity calculations are:

1. For frame members not subjected to any bending, and for truss members, the axial compression capacity in general column flexural buckling is calculated from Cl.13.3.1 using the slenderness ratios for the local Y-Y and Z-Z axis. The parameters KY, LY, KZ and LZ are applicable for this.

Page 602: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-18

3. The axial compression capacity is also calculated by taking flexural-torsional buckling into account. Parameters KX and LX may be used to provide the effective length factor and effective length value for flexural-torsional buckling. Flexural-torsional buckling capacity is computed for single channels, single angles, Tees and Double angles.

4. While computing the general column flexural buckling capacity of sections with axial compression + bending, the special provisions of 13.8.1(a), 13.8.1(b) and 13.8.1(c) are applied. For example, Lambda = 0 for 13.8.1(a), K=1 for 13.8.1(b), etc.)

Bending

Where Phi = Resistance factor = 0.9

The laterally unsupported length of the compression flange for the purpose of computing the factored moment resistance is specified in STAAD with the help of the parameter UNL. If UNL is less than one tenth the member length (member length is the distance between the joints of the member), the member is treated as being continuously laterally supported. In this case, the moment resistance is computed from Clause 13.5 of the code. If UNL is greater than or equal to one-tenth the member length, its value is used as the laterally unsupported length. The equations of Clause 13.6 of the code are used to arrive at the moment of resistance of laterally unsupported members. Some of the aspects of the bending capacity calculations are: 1. The weak axis bending capacity of all sections except single

angles is calculated as

For Class 1 & 2 sections, Phi*Py*Fy For Class 3 sections, Phi*Sy*Fy

Py = Plastic section modulus about the local Y axis Sy = Elastic section modulus about the local Y axis Fy = Yield stress of steel

Page 603: International Design Codes

Section 12B 12-19

2. For single angles sections are not designed by STAAD, as the South African code doesn’t provide any clear guidelines for calculating this value.

3. For calculating the bending capacity about the Z-Z axis of singly symmetric shapes such as Tees and Double angles, SAB0162-1: 1993 stipulates in Clause 13.6(b), page 31, that a rational method

Axial compression and bending The member strength for sections subjected to axial compression and uniaxial or biaxial bending is obtained through the use of interaction equations. In these equations, the additional bending caused by the action of the axial load is accounted for by using amplification factors. Clause 13.8 of the code provides the equations for this purpose. If the summation of the left hand side of these equations exceeds 1.0 or the allowable value provided using the RATIO parameter (see Table 3B.1), the member is considered to have FAILed under the loading condition. Axial tension and bending

Shear

Members subjected to axial tension and bending are also designed using interaction equations. Clause 13.9 of the code is used to perform these checks. The actual RATIO is determined as the value of the left hand side of the critical equation.

The shear resistance of the cross section is determined using the equations of Clause 13.4 of the code. Once this is obtained, the ratio of the shear force acting on the cross section to the shear resistance of the section is calculated. If any of the ratios (for both local Y & Z axes) exceed 1.0 or the allowable value provided using the RATIO parameter (see Table 3B.1), the section is considered to have failed under shear. The code also requires that the slenderness ratio of the web be within a certain limit (See Cl.13.4.1.3, page 29 of SABS 0162-1:1993). Checks for safety in shear are performed only if this value is within the allowable limit.

Page 604: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-20

Users may by-pass this limitation by specifying a value of 2.0 for the MAIN parameter.

12B.7 Design Parameters

The design parameters outlined in table below may be used to control the design procedure. These parameters communicate design decisions from the engineer to the program and thus allows the engineer to control the design process to suit an application's specific needs. The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements, some or all of these parameter values may be changed to exactly model the physical structure.

South African steel design parameters

Parameter

Name

Default Value Description

Kt 1.0 K value for flexural torsional buckling

Ky 1.0 K value in local Y-axis, usually minor axis

Kz 1.0 K value in local Z-axis, usually major axis

Lt Member length Length for flexural torsional buckling

Ly Member length Length in local Y axis for slenderness value KL/r

Lz Member length Length in local Z axis for slenderness value KL/r

Fyld 300Mpa Yield strength of steel

Fu 345Mpa Ultimate strength of steel

NSF 1.0 Net section factor for tension members

UNT Member Length Unsupported length in bending compression of top flange for calculating moment resistance

Page 605: International Design Codes

Section 12B 12-21

South African steel design parameters

Parameter

Name

Default Value Description

UNB Member Length Unsupported length in bending compression of bottom flange for calculating moment resistance

Main 0 - For Check for slenderness. 0

Flag for controlling slenderness check

1 - For Do not check for slenderness

Cb 1.0

Greater than 0.0 and less than 2.5,Value of Omega_2 (C1.13.6) to be used for calculation

Equal to 0.0: Calculate Omega_2

Ssy 0

Sidesway parameter

0 - Sideway about local Y-axis.

1 - No sideway about local Y-axis.

Ssz

1 - No sideway about local Z-axis.

0

Sidesway parameter

0 - Sideway about local Z-axis.

Cmy 1.0 1 - Do not calculate Omega-1 for local Y axis.

2 - Calculate Omega-1 for local Y axis

Cmz 1.0 1 - Do not calculate Omega-1 for local Z axis.

2 - Calculate Omega-1 for local Z axis

Track 0

Track parameter

0 = Print the design output at the minimum detail level.

1 = Print the design output at the intermediate detail level.

2 = Print the design output at maximum detail level

Page 606: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-22

South African steel design parameters

Parameter

Name

Default Value Description

Dmax 1000 Maximum allowable depth

Dmin 0 Minimum required depth

Ratio 1.0

Permissible ratio of applied load to section capacity

Used in altering the RHS of critical interaction equations

Beam 0

0 - Perform design at ends and those locations specified in the section command.

1 - Perform design at ends and 1/12th section locations along member length.

Dff 0 Default is 0 indicating that deflection check is not performed

Dj1 0

Start node of physical member for determining deflected pattern for deflection check and should be set along with DFF parameter

Dj2 0

End node of physical member for determining deflected pattern for deflection check and should be set along with DFF parameter

12B.8 Code Checking

The purpose of code checking is to determine whether the current section properties of the members are adequate to carry the forces obtained from the most recent analysis. The adequacy is checked as per the SAB0162-1: 1993 requirements.

Page 607: International Design Codes

Section 12B 12-23

Code checking is done using forces and moments at specified sections of the members. If the BEAM parameter for a member is set to 1 (which is also its default value), moments are calculated at every twelfth point along the beam. When no section locations are specified and the BEAM parameter is set to zero, design will be based on member start and end forces only. The code checking output labels the members as PASSed or FAILed. In addition, the critical condition, governing load case, location (distance from the start joint) and magnitudes of the governing forces and moments are also printed. Using the TRACK parameter can control the extent of detail of the output. PARAMETER CODE SAB0162 MAIN 1 all LY 4 MEMB 1 LZ 4 MEMB 1 UNL 4 MEMB 1 CB 0 MEMB 1 TO 23 CMZ MEMB 2 1 TO 23 CMY MEMB 2 1 TO 23 SSY 0 MEMB 1 TO 23 SSZ 0 MEMB 1 TO 23 FU 450000 MEMB 1 TO 23 BEAM 1 ALL NSF 0.85 ALL KY 1.2 MEMB 3 4 RATIO 1.0 ALL TRACK 2 ALL FYLD 300000 1 TO 23 CHECK CODE ALL FINISH

Page 608: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-24

12B.9 Member Selection

The member selection process involves determination of the least weight member that PASSes the code checking procedure based on the forces and moments of the most recent analysis. The section selected will be of the same type as that specified initially. For example, a member specified initially as a channel will have a channel selected for it. Selection of members whose properties are originally provided from a user table will be limited to sections in the user table. Member selection cannot be performed on members listed as PRISMATIC.

12B.10 Tabulated Results of Steel Design

Results of code checking and member selection are presented in a tabular format. The term CRITICAL COND refers to the section of the SAB0162-1: 1993 specification, which governed the design.

If the TRACK parameter is set to 1.0, the output will be displayed as follows:

************************************** STAAD.PRO CODE CHECKING (SOUTHAFRICAN STEEL/SAB-0162-01(1993)) ************************************** ALL UNITS ARE - KNS MET (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= * 1 ST PFC140X60 (SOUTHAFRICAN SECTIONS) FAIL SAB-13.9 4.321 1 -20.00 0.00 82.53 0.00 |---------------------------------------------------------------------| | FACTORED RESISTANCES FOR MEMBER- 1 UNIT - KN,M PHI = 0.90 | | MRZ= 14.35 MRY= 3.86 | | CR= 58.41 TR= 425.81 VR= 123.85 | |---------------------------------------------------------------------|

Factored member resistances will be printed out. Following is a description of some of the items printed out. MRZ= Factored moment of resistance in z direction

Page 609: International Design Codes

Section 12B 12-25

MRY= Factored moment of resistance in z direction CR = Factored compressive resistance for column

TR= Factored tensile capacity VR= Factored shear resistance Further details can be obtained by setting TRACK to 2.0. A typical output of track 2.0 parameter is as follows.

************************************** STAAD.PRO CODE CHECKING (SOUTHAFRICAN STEEL/SAB-0162-01(1993)) ************************************** ALL UNITS ARE - KNS MET (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= * 1 ST PFC140X60 (SOUTHAFRICAN SECTIONS) FAIL SAB-13.9 4.321 1 -20.00 0.00 82.53 0.00 MEMBER PROPERTIES (UNIT = CM) ----------------------------- CROSS SECTION AREA = 1.95E+01 MEMBER LENGTH = 4.50E+02 IZ = 6.05E+02 SZ = 8.64E+01 PZ = 4.24E+02 IY = 6.91E+01 SY = 1.73E+01 PY = 1.52E+02 MATERIAL PROPERTIES (UNIT = MPA) -------------------------------- FYLD = 248.2 FU = 285.4 SECTION CAPACITIES (UNIT - KN,M) --------------------------------- CRY = 5.841E+01 CRZ = 2.947E+02 CTORFLX = 2.021E+02 TENSILE CAPACITY = 4.258E+02 COMPRESSIVE CAPACITY = 5.841E+01 FACTORED MOMENT RESISTANCE : MRY = 3.859E+00 MRZ = 1.435E+01 FACTORED SHEAR RESISTANCE : VRY = 1.238E+02 VRZ = 1.168E+02 MISCELLANEOUS INFORMATION -------------------------- NET SECTION FACTOR FOR TENSION = 1.000 KL/RY = 239.051 KL/RZ = 80.789 ALLOWABLE KL/R = 300.000 UNSUPPORTED LENGTH OF THE COMPRESSION FLANGE (M) = 4.500 OMEGA-1 (Y-AXIS) = 1.00 OMEGA-1 (Z-AXIS) = 1.00 OMEGA-2 = 1.00 SHEAR FORCE (KNS) : Y AXIS = 0.000E+00 Z AXIS = 3.526E+01 SLENDERNESS RATIO OF WEB (H/W) = 2.00E+01

Page 610: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-26

Following is a description of some of the items printed out. CRY Factored compressive resistance for column buckling

about the local y axis CRZ Factored compressive resistance for column buckling

about the local z axis CTORFLX Factored compressive resistance against torsional

flexural buckling TENSILE CAPACITY

Factored tensile capacity

COMPRESSIVE CAPACITY

Factored compressive capacity

FACTORED MOMENT RESISTANCE

MRY = Factored moment of resistance in y direction MRZ = Factored moment of resistance in z direction

FACTORED SHEAR RESISTANCE

VRY = Factored shear resistance in y direction VRZ = Factored shear resistance in z direction

12B.11 Verification Problems

In the next few pages are included 3 verification examples for reference purposes.

Page 611: International Design Codes

Section 12B 12-27

Verification Problem No. 1

Objective: - To determine the capacity of a South African I-section column in axial compression. Column is braced at its ends for both axes.

Design Code: - South African steel design code (SAB:0162-

1(1993)) Reference: - Example 4.3.4.1, page 4.18, Structural Steel

Design to SAB:0162-1(1993)(Limit state Design) by Greg Parrott, 1st edition, Shades Technical publication

Given: - FYLD = 300Mpa Length = 6000mm Comparison: -

Solution Design Strength (kN) Theory 1516 STAAD 1516 Difference No

Page 612: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-28

**************************************************** * * * STAAD.Pro * * Version Bld * * Proprietary Program of * * Research Engineers, Intl. * * Date= * * Time= * * * * USER ID: * **************************************************** 1. STAAD PLANE 2. START JOB INFORMATION 3. ENGINEER DATE 4. END JOB INFORMATION 5. INPUT WIDTH 79 6. *********************************************** 7. * STAAD.PRO GENERATED COMMENT * 8. *********************************************** 9. *1 0 0 0,2 0 6 0 10. *********************************************** 11. UNIT METER KN 12. JOINT COORDINATES 13. 1 0 0 0; 2 0 6 0 14. MEMBER INCIDENCES 15. 1 1 2 16. MEMBER PROPERTY SAFRICAN 17. 1 TABLE ST 356X67UB 18. DEFINE MATERIAL START 19. ISOTROPIC MATERIAL1 20. E 2.0E+008 21. POISSON 0.3 22. DENSITY 76.977 23. ISOTROPIC STEEL 24. E 2.00E+008 25. POISSON 0.3 26. DENSITY 76.8195 27. ALPHA 1.2E-005 28. DAMP 0.03 29. END DEFINE MATERIAL 30. UNIT MMS KN 31. CONSTANTS 32. MATERIAL STEEL MEMB 1 33. UNIT METER KN 34. SUPPORTS 35. 1 FIXED 36. LOAD 1 LOADTYPE NONE TITLE LOAD CASE 1 37. JOINT LOAD 38. 2 FY -1500 39. PERFORM ANALYSIS P R O B L E M S T A T I S T I C S ----------------------------------- NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 2/ 1/ 1 ORIGINAL/FINAL BAND-WIDTH= 1/ 1/ 3 DOF TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 3 SIZE OF STIFFNESS MATRIX = 0 DOUBLE KILO-WORDS REQRD/AVAIL. DISK SPACE = 12.0/ 3978.5 MB 40. PARAMETER 41. CODE SAB0162 42. LZ 6 ALL 43. LY 3 ALL 44. FU 450000 ALL 45. BEAM 1 ALL 46. NSF 0.85 ALL 47. TRACK 2 ALL 48. FYLD 300000 ALL 49. CHECK CODE ALL

Page 613: International Design Codes

Section 12B 12-29

************************************** STAAD.PRO CODE CHECKING (SOUTHAFRICAN STEEL/SAB-0162-01(1993)) ************************************** ALL UNITS ARE - KNS MET (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 1 ST 356X67UB (SOUTHAFRICAN SECTIONS) PASS SAB-13.8 0.989 1 1500.00 0.00 0.00 0.00 MEMBER PROPERTIES (UNIT = CM) ----------------------------- CROSS SECTION AREA = 8.55E+01 MEMBER LENGTH = 6.00E+02 IZ = 1.95E+04 SZ = 1.07E+03 PZ = 1.21E+03 IY = 1.36E+03 SY = 1.57E+02 PY = 2.43E+02 MATERIAL PROPERTIES (UNIT = MPA) -------------------------------- FYLD = 300.0 FU = 345.0 SECTION CAPACITIES (UNIT - KN,M) --------------------------------- CRY = 1.516E+03 CRZ = 2.038E+03 CTORFLX = 1.516E+03 TENSILE CAPACITY = 1.918E+03 COMPRESSIVE CAPACITY = 1.516E+03 FACTORED MOMENT RESISTANCE : MRY = 6.561E+01 MRZ = 1.992E+02 FACTORED SHEAR RESISTANCE : VRY = 5.903E+02 VRZ = 6.461E+02 MISCELLANEOUS INFORMATION -------------------------- NET SECTION FACTOR FOR TENSION = 0.850 KL/RY = 75.220 KL/RZ = 39.730 ALLOWABLE KL/R = 200.000 UNSUPPORTED LENGTH OF THE COMPRESSION FLANGE (M) = 6.000 OMEGA-1 (Y-AXIS) = 1.00 OMEGA-1 (Z-AXIS) = 1.00 OMEGA-2 = 1.00 SHEAR FORCE (KNS) : Y AXIS = 0.000E+00 Z AXIS = 0.000E+00 SLENDERNESS RATIO OF WEB (H/W) = 3.65E+01 50. FINISH

Page 614: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-30

Verification Problem No. 2

Reference: - Example 4.5, page 4.37, Structural Steel Design to

SAB:0162-1(1993)(Limit state Design) by Greg Parrott, 1st edition, Shades Technical publication

Objective:- To determine the capacity of a South African I-section beam in bending. The beam has torsional and simple lateral rotational restraint at the supports, and the applied point load provides effective lateral restraint at the point of application is braced at its ends for both axes.

Design Code: - South African steel design code (SAB:0162-

1(1993))

Given: - FYLD = 300Mpa Comparison: -

Solution Design Strength (kN-m) Theory 353.4 STAAD 353.3 Difference Small

Page 615: International Design Codes

Section 12B 12-31

**************************************************** * * * STAAD.Pro * * Version Bld * * Proprietary Program of * * Research Engineers, Intl. * * Date= * * Time= * * * * USER ID: * **************************************************** 1. STAAD PLANE 2. START JOB INFORMATION 3. ENGINEER DATE 4. END JOB INFORMATION 5. INPUT WIDTH 79 6. UNIT METER KN 7. JOINT COORDINATES 8. 1 0 0 0; 2 10 0 0; 3 7 0 0 9. MEMBER INCIDENCES 10. 1 1 3; 2 3 2 11. MEMBER PROPERTY SAFRICAN 12. 1 2 TABLE ST 406X67UB 13. DEFINE MATERIAL START 14. ISOTROPIC MATERIAL1 15. E 2.0E+008 16. POISSON 0.3 17. DENSITY 76.977 18. ISOTROPIC STEEL 19. E 2.00E+008 20. POISSON 0.3 21. DENSITY 76.8195 22. ALPHA 1.2E-005 23. DAMP 0.03 24. END DEFINE MATERIAL 25. UNIT MMS KN 26. CONSTANTS 27. MATERIAL STEEL MEMB 1 2 28. UNIT METER KN 29. SUPPORTS 30. 1 3 PINNED 31. LOAD 1 LOADTYPE NONE TITLE LOAD CASE 1 32. MEMBER LOAD 33. 1 CON GY -104 4 34. 1 UNI GY -26.4 35. 2 UNI GY -7.2 36. PERFORM ANALYSIS P R O B L E M S T A T I S T I C S ----------------------------------- NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 3/ 2/ 2 ORIGINAL/FINAL BAND-WIDTH= 2/ 2/ 5 DOF TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 5 SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS REQRD/AVAIL. DISK SPACE = 12.0/ 3978.5 MB 37. PARAMETER 38. CODE SABS0162 39. CB 0 ALL 40. UNL 4 MEMB 1 41. FU 450000 ALL 42. BEAM 1 ALL 43. NSF 0.85 ALL 44. FYLD 300000 ALL 45. TRACK 2 ALL 46. CHECK CODE MEMB 1

Page 616: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-32

************************************** STAAD.PRO CODE CHECKING (SOUTHAFRICAN STEEL/SAB-0162-01(1993)) ************************************** ALL UNITS ARE - KNS MET (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= 1 ST 406X67UB (SOUTHAFRICAN SECTIONS) PASS SHEAR 0.244 1 0.00 0.00 32.40 7.00 MEMBER PROPERTIES (UNIT = CM) ----------------------------- CROSS SECTION AREA = 8.55E+01 MEMBER LENGTH = 7.00E+02 IZ = 2.43E+04 SZ = 1.19E+03 PZ = 1.35E+03 IY = 1.36E+03 SY = 1.52E+02 PY = 2.37E+02 MATERIAL PROPERTIES (UNIT = MPA) -------------------------------- FYLD = 300.0 FU = 345.0 SECTION CAPACITIES (UNIT - KN,M) --------------------------------- CRY = 4.532E+02 CRZ = 2.016E+03 CTORFLX = 4.532E+02 TENSILE CAPACITY = 1.918E+03 COMPRESSIVE CAPACITY = 4.532E+02 FACTORED MOMENT RESISTANCE : MRY = 6.399E+01 MRZ = 3.533E+02 FACTORED SHEAR RESISTANCE : VRY = 6.420E+02 VRZ = 6.075E+02 MISCELLANEOUS INFORMATION -------------------------- NET SECTION FACTOR FOR TENSION = 0.850 KL/RY = 175.514 KL/RZ = 41.522 ALLOWABLE KL/R = 300.000 UNSUPPORTED LENGTH OF THE COMPRESSION FLANGE (M) = 4.000 OMEGA-1 (Y-AXIS) = 1.00 OMEGA-1 (Z-AXIS) = 1.00 OMEGA-2 = 1.75 SHEAR FORCE (KNS) : Y AXIS = 0.000E+00 Z AXIS = -1.565E+02 SLENDERNESS RATIO OF WEB (H/W) = 4.33E+01 47. FINISH

Page 617: International Design Codes

Section 12B 12-33

Verification Problem No. 3

Objective: - To determine the elastic shear capacity of a South African I-section which is simply supported over the span of 8 m

Design Code: - South African steel design code (SAB:0162-1(1993)) Reference: - Example 4.6.5, page 4.54, Structural Steel Design to

SAB:0162-1(1993)(Limit state Design) by Greg Parrott, 1st edition, Shades Technical publication

Comparison: -

Given: - FYLD = 300Mpa

Solution Design Strength (kN) Theory 687.1 STAAD 687.1 Difference No

Page 618: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-34

**************************************************** * * * STAAD.Pro * * Version Bld * * Proprietary Program of * * Research Engineers, Intl. * * Date= * * Time= * * * * USER ID: * **************************************************** 1. STAAD PLANE 2. START JOB INFORMATION 3. ENGINEER DATE 4. END JOB INFORMATION 5. INPUT WIDTH 79 6. UNIT METER KN 7. JOINT COORDINATES 8. 1 0 0 0; 2 8 0 0 9. MEMBER INCIDENCES 10. 1 1 2 11. MEMBER PROPERTY SAFRICAN 12. 1 TABLE ST 457X67UB 13. DEFINE MATERIAL START 14. ISOTROPIC MATERIAL1 15. E 2E+008 16. POISSON 0.3 17. DENSITY 76.977 18. ISOTROPIC STEEL 19. E 2E+008 20. POISSON 0.3 21. DENSITY 76.8195 22. ALPHA 1.2E-005 23. DAMP 0.03 24. END DEFINE MATERIAL 25. UNIT MMS KN 26. CONSTANTS 27. MATERIAL STEEL MEMB 1 28. UNIT METER KN 29. SUPPORTS 30. 1 2 PINNED 31. LOAD 1 LOADTYPE NONE TITLE LOAD CASE 1 32. MEMBER LOAD 33. 1 UNI GY -70 34. PERFORM ANALYSIS P R O B L E M S T A T I S T I C S ----------------------------------- NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 2/ 1/ 2 ORIGINAL/FINAL BAND-WIDTH= 1/ 1/ 2 DOF TOTAL PRIMARY LOAD CASES = 1, TOTAL DEGREES OF FREEDOM = 2 SIZE OF STIFFNESS MATRIX = 0 DOUBLE KILO-WORDS REQRD/AVAIL. DISK SPACE = 12.0/ 3978.4 MB 35. PARAMETER 36. CODE SABS0162 37. FU 450000 ALL 38. BEAM 1 ALL 39. FYLD 300000 ALL 40. TRACK 2 ALL 41. CHECK CODE ALL

Page 619: International Design Codes

Section 12B 12-35

************************************** STAAD.PRO CODE CHECKING (SOUTHAFRICAN STEEL/SAB-0162-01(1993)) ************************************** ALL UNITS ARE - KNS MET (UNLESS OTHERWISE NOTED) MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/ FX MY MZ LOCATION ======================================================================= * 1 ST 457X67UB (SOUTHAFRICAN SECTIONS) FAIL CLASS 4 SECT 2.000 0.00 0.00 0.00 MEMBER PROPERTIES (UNIT = CM) ----------------------------- CROSS SECTION AREA = 8.55E+01 MEMBER LENGTH = 8.00E+02 IZ = 2.94E+04 SZ = 1.30E+03 PZ = 1.47E+03 IY = 1.45E+03 SY = 1.53E+02 PY = 2.37E+02 MATERIAL PROPERTIES (UNIT = MPA) -------------------------------- FYLD = 300.0 FU = 345.0 SECTION CAPACITIES (UNIT - KN,M) --------------------------------- CRY = 0.000E+00 CRZ = 0.000E+00 CTORFLX = 0.000E+00 TENSILE CAPACITY = 2.257E+03 COMPRESSIVE CAPACITY = 0.000E+00 FACTORED MOMENT RESISTANCE : MRY = 4.123E+01 MRZ = 0.000E+00 FACTORED SHEAR RESISTANCE : VRY = 6.871E+02 VRZ = 5.730E+02 MISCELLANEOUS INFORMATION -------------------------- NET SECTION FACTOR FOR TENSION = 1.000 KL/RY = 194.263 KL/RZ = 43.142 ALLOWABLE KL/R = 200.000 UNSUPPORTED LENGTH OF THE COMPRESSION FLANGE (M) = 8.000 OMEGA-1 (Y-AXIS) = 1.00 OMEGA-1 (Z-AXIS) = 1.00 OMEGA-2 = 1.00 SHEAR FORCE (KNS) : Y AXIS = 0.000E+00 Z AXIS = 2.800E+02 SLENDERNESS RATIO OF WEB (H/W) = 5.04E+01 42. FINISH

Page 620: International Design Codes

South African Steel Code Per SAB Standard SAB0162–1: 1993 Section 12B 12-36

Page 621: International Design Codes

Section 13 American Aluminum

Code

Page 622: International Design Codes
Page 623: International Design Codes

13-1

Design Per American Aluminum Code

Section 13

13.1 General

STAAD is currently equipped with the facilities to perform design based on the specifications for Aluminum Structures. The requirements of the Allowable Stress Design, Sixth edition, October 1994, have been implemented. The various issues related to the implementation of this code in STAAD are explained below.

13.2 Member Properties

In order to do this design in STAAD, the members in the structure must have their properties specified from Section VI of the above-mentioned manual. The section names are mentioned in Tables 5 through 28 of that manual. All of those tables except Table 10 (Wing Channels) and Table 20 (Bulb Angles) are available in STAAD. Described below is the command specification for various sections: Standard single section

memb-list TA ST section-name

Page 624: International Design Codes

Design Per American Aluminum Code Section 13 13-2

Example 1 TO 5 TA ST CS12X11.8 9 TA ST I8.00X13.1 11 33 45 67 TA ST LS8.00X8.00X0.625 18 TA ST 1.50PipeX160 15 TA ST T(A-N)6.00X8.00X11.2 23 25 29 TA ST 20X12RectX.500Wall

Double channel back-to-back

memb-list TA BACK section-name SPACING value

Example 3 TA BACK C(A-N)7X3.61 SPACING 1.5 5 TA BACK C15X17.33 SP 0.75

Double channel front-to-front

memb-list TA FRONT section-name SPACING value

Example 2 TA FRONT CS12X10.3 SP 1.0 4 TA FR CS10X10.1 SP 0.5

Page 625: International Design Codes

Section 13 13-3

Double angle long leg back-to-back

memb-list TA LD section-name SPACING value

Example 14 TA LD LS4.00X3.00X0.375 SP 1.5

Double angle short leg back-to-back

memb-list TA SD section-name SPACING value

Example 12 TA SD L3.5X3X0.5 SP 0.25 13 TA SD L8X6X0.75 SP 1.0

13.3 Design Procedure

The design is done according to the rules specified in Sections 4.1, 4.2 and 4.4 on pages I-A-41 and I-A-42 of the Aluminum code. The allowable stresses for the various sections are computed according to the equations shown in Section 3.4.1 through 3.4.21 on pages I-A-27 through I-A-40. The adequacy of the member is checked by calculating the value of the left-hand side of equations 4.1.1-1, 4.1.1-2, 4.1.1-3, 4.1.2-1, 4.4-1 and 4.4-2. This left-hand side value is termed as RATIO. If the highest RATIO among these equations turns out to be less than or equal to 1.0, the member is declared as having PASSed. If it exceeds 1.0, the member has FAILed the design requirements.

Page 626: International Design Codes

Design Per American Aluminum Code Section 13 13-4

The check for torsion per Clause 4.3 for open sections is currently not done.

13.4 Design Parameters

The following are the parameters for specifying the values for variables associated with the design.

Table 13.1 Aluminum Design Parameters

Parameter Default Description Name Value ALLOY 34 This variable can take on a value from 1 through 40.

The default value represents the alloy 6061-T6. See Table 12A.2 in the following pages for a list of values for this parameter and the alloy they represent. Table 3.3-1 in Section I-B of the Aluminum specifications provides information on the properties of the various alloys.

PRODUCT 1 This variable can take on a value from 1 through 4. They represent: 1 - All 2 - Extrusions 3 - Drawn Tube 4 - Pipe The default value stands for All. The PRODUCT parameter finds mention in Table 3.3-1 in Section I-B of the Aluminum specifications.

ALCLAD 0 This variable can take on a value of either 0 or 1. 0 - Material used in the section is not an Alclad. 1 - Material used in the section is an Alclad.

WELD 0 In Table 3.4-2 in Section I-A of the Aluminum specifications, it is mentioned that the value of coefficients Kt and Kc are dependent upon whether or not, the location of the section where design is done is within 1.0 inch of a weld. The WELD parameter is used in STAAD for this purpose. The values that can be assigned to this parameter are: 0 - Region is farther than 1.0in from a weld 1 - Region is within 1.0in from a weld

Page 627: International Design Codes

Section 13 13-5

Table 13.1 Aluminum Design Parameters

Parameter Default Description Name Value STRUCTURE 1 In Table 3.4-1 in Section I-A of the Aluminum

specifications, it is mentioned that the value of coefficients nu, ny and na are dependent upon whether the structure being designed is a building or a bridge. Users may convey this information to STAAD using the parameter STRUCTURE. The values that can be assigned to this parameter are: 1 - Buildings and similar type structures 2 - Bridges and similar type structures

DMAX 1000 in. Maximum depth permissible for the section during member selection. This value must be provided in the current units.

DMIN 0.0 in Minimum depth required for the section during member selection. This value must be provided in the current units.

UNL Member length

Distance between points where the compression flange is braced against buckling or twisting. This value must be provided in the current units. This value is used to compute the allowable stress in bending compression.

KY 1.0 Effective length factor for overall column buckling in the local Y-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the allowable stress in axial compression.

LY Member length

Effective length for overall column buckling in the local Y-axis. It is input in the current units of length. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the allowable stress in axial compression.

Page 628: International Design Codes

Design Per American Aluminum Code Section 13 13-6

Table 13.1 Aluminum Design Parameters

Parameter Default Description Name Value KZ 1.0 Effective length factor for overall column buckling in

the local Z-axis. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the allowable stress in axial compression.

LZ Member length

Effective length for overall column buckling in the local Z-axis. It is input in the current units of length. Values can range from 0.01 (for a column completely prevented from buckling) to any user specified large value. It is used to compute the KL/R ratio for determining the allowable stress in axial compression.

KT 1.0 Effective length factor for torsional buckling. It is a fraction and is unit-less. Values can range from 0.01 (for a column completely prevented from torsional buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the allowable stress in axial compression. See Equation 3.4.7.2-6 on page I-A-28 of the Aluminum specifications for details.

LT Member length

Unbraced length for twisting. It is input in the current units of length. Values can range from 0.01 (for a column completely prevented from torsional buckling) to any user specified large value. It is used to compute the KL/R ratio for twisting for determining the allowable stress in axial compression. See Equation 3.4.7.2-6 on page I-A-28 of the Aluminum specifications for details.

STIFF Member length

Spacing in the longitudinal direction of shear stiffeners for stiffened flat webs. It is input in the current units of length. See section 3.4.21 on page I-A-40 of the Aluminum specifications for information regarding this parameter.

Page 629: International Design Codes

Section 13 13-7

Table 13.1 Aluminum Design Parameters

Parameter Default Description Name Value SSY 0.0 Factor that indicates whether or not the structure is

subjected to sidesway along the local Y axis of the member. The values are: 0 - Sidesway is present along the local Y-axis of the member 1 - There is no sidesway along the local Y-axis of the member. The sidesway condition is used to determine the value of Cm explained in Section 4.1.1, page I-A-41 of the Aluminum specifications.

SSZ 0.0 Factor that indicates whether or not the structure is subjected to sidesway along the local Z axis of the member. The values are: 0 - Sidesway is present along the local Z-axis of the member 1 - There is no sidesway along the local Z-axis of the member. The sidesway condition is used to determine the value of Cm explained in Section 4.1.1, page I-A-41 of the Aluminum specifications.

TRACK 2 This parameter is used to control the level of detail in which the design output is reported in the output file. The allowable values are: 1 - Prints only the member number, section name,

ratio, and PASS/FAIL status. 2 - Prints the design summary in addition to that

printed by TRACK 1 3 - Prints the member properties and alloy properties in addition to that printed by TRACK 2. 4 - Prints the values of variables used in design in

addition to that printed by TRACK 3.

Page 630: International Design Codes

Design Per American Aluminum Code Section 13 13-8

Table 13.1 Aluminum Design Parameters

Parameter Default Description Name Value BEAM 0.0 If this parameter is set to 1.0, the adequacy of the

member is determined by checking a total of 13 equally spaced locations along the length of the member. If the BEAM value is 0.0, the 13 location check is not conducted, and instead, checking is done only at the locations specified by the SECTION command (See STAAD manual for details). If neither the BEAM parameter nor any SECTION command is specified, STAAD will terminate the run and ask the user to provide one of those 2 commands. This rule is not enforced for TRUSS members.

13.5 Code Checking

The purpose of code checking is to determine whether the initially specified member properties are adequate to carry the forces transmitted to the member due to the loads on the structure. Code checking is done at the locations specified by either the SECTION command or the BEAM parameter described above. It is done with the aid of the command “CHECK CODE” described in the main STAAD Technical Reference Manual. Example Problem 1 in the Getting Started and Examples Manual for STAAD provides an example on the usage of the CHECK CODE command.

13.6 Member Selection

The member selection process involves the determination of the least weight member that PASSes the code checking procedure based on the forces and moments of the most recent analysis. The section selected will be of the same type as that specified initially. For example, a member specified initially as a channel will have a channel selected for it. It is done with the aid of the command “SELECT MEMBER” described in the main STAAD Technical

Page 631: International Design Codes

Section 13 13-9

Reference Manual. Example Problem 1 in the Getting Started and Examples Manual for STAAD provides an example on the usage of the SELECT MEMBER command.

Sample input data for Aluminum Design PARAMETER CODE ALUMIMUM BEAM 1 ALL KY 1.2 MEMB 3 4 ALLOY 35 ALL PRODUCT 2 ALL TRACK 3 ALL SELECT ALL ALCLAD 1 ALL STRUCT 1 ALL CHECK CODE ALL

Page 632: International Design Codes

Design Per American Aluminum Code Section 13 13-10

Table 13.2 - ALLOY PARAMETER :

Values and Corresponding Names 1 1100-H12 2 1100-H14 3 2014-T6 4 2014-T6510 5 2014-T6511 6 2014-T651 7 3003-H12 8 3003-H14 9 3003-H16 10 3003-H18 11 3004-H32 12 3004-H34 13 3004-H36 14 3004-H38 15 5005-H12 16 5005-H14 17 5005-H32 18 5005-H34 19 5050-H32 20 5050-H34 21 5052-H32 22 5052-H34 23 5083-H111 24 5086-H111 25 5086-H116 26 5086-H32 27 5086-H34 28 5454-H111 29 5454-H112 30 5456-H111 31 5456-H112 32 6005-T5 33 6105-T5

Page 633: International Design Codes

Section 13 13-11

34 6061-T6 35 6061-T6510 36 6061-T6511 37 6061-T651 38 6063-T5 39 6063-T6 40 6351-T5

Page 634: International Design Codes

Design Per American Aluminum Code Section 13 13-12

Page 635: International Design Codes

American Transmission Tower Code

Section 14

Page 636: International Design Codes
Page 637: International Design Codes

14-1

Steel Design per ASCE 10-97

14A.1 General Comments

CODE ASCE 52

Design is available for all standard sections listed in the AISC ASD 9th edition manual, namely, Wide Flanges, S, M, HP, Tees, Channels, Single Angles, Double Angles, Tubes and Pipes. Design

Section 14A

The design of structural steel members in accordance with the specifications of ASCE Standard 10-97 – Design of Latticed Steel Transmission Structures is now implemented. This code is meant to supercede the older edition of the code, available under the name ASCE Publication 52. However, in the interests of backward compatibility, both codes are currently accessible in STAAD.Pro. To access the ASCE 52 code, use the commands

PARAMETER

To access the ASCE 10-97 code, use the commands

PARAMETER CODE ASCE

In general, the concepts followed in MEMBER SELECTION and CODE CHECKING procedures are similar to that of the AISC based design. It is assumed that the user is familiar with the basic concepts of steel design facilities available in STAAD. Please refer to Section 2 of the STAAD Technical Reference Manual for detailed information on this topic. This section specifically addresses the implementation of steel design based on ASCE 10-97.

Page 638: International Design Codes

Steel Design Per ASCE 10-97 Section 14A14-2

of HSS sections (those listed in the 3rd edition AISC LRFD manual) and Composite beams (I shapes with concrete slab on top) is not suppported.

14A.2 Allowable Stresses per ASCE 10 - 97

Member selection and code checking operations in the STAAD implementation of ASCE 10-97 are done to resist loads at stresses approaching yielding, buckling, fracture and other limiting conditions specified in the standard. Those stresses are referred to in the standard as Design Stresses. The appropriate sections of the ASCE standard where the procedure for calculating the design stresses are explained are as follows.

Design Axial Tensile Stress

Design tensile stresses are calculated on the basis of the procedure described in section 3.10. The NSF parameter (see the Parameters table shown later in this section) may be used if the section area needs to be reduced to account for bolt holes.

Design Axial Compressive Stress

Design compressive stress calculation is based on the procedures of section 3.6 through 3.9. For angle members under compression, the procedure of sections 3.7 and 3.8 have been implemented. Capacity of the section is computed for column buckling and wherever applicable, torsional buckling. The user may control the effective lengths for buckling using the LT, LY, LZ and/or KT, KY, KZ parameters (see the Parameters table shown later in this section). Design Bending Compressive Stress

Calculations for design bending compressive stress about the major axis and minor axis are based on the procedures of section 3.14. Procedures outlined in sections 3.14.1 through 3.14.6 have been implemented.

Page 639: International Design Codes

Section 14A 14-3

Design Bending Tensile Stress

Calculations for design bending tensile stress about the major and minor axis are based on the procedures of section 3.14.2. Design Shear Stress

Calculation of the design shear stress is based on the procedure outlined in section 3.15 of the ASCE 10-97. The procedure of section 3.15.2 is followed for angles and the procedure of section 3.15.1 is followed for all other sections.

14A.3 Critical Conditions used as criteria to determine Pass/Fail status

These are Clause 3.4 for slenderness limits, Clause 3.12 for Axial Compression and Bending, Clause 3.13 for Axial Tension and Bending, Clause 3.9.2 for Maximum w/t ratios and Clause 3.15 for Shear.

14A.4 Design Parameters

Design per ASCE (10-97) must be initiated by using the command CODE ASCE. This command should be the first command after the PARAMETER statement. Other applicable parameters are summarized in the table shown later in this section. These parameters may be used to control the design process to suit specific modeling needs. The default parameter values have been selected such that they are frequently used numbers for conventional design.

14A.5 Code Checking and Member Selection

Both code checking and member selection options are available in the ASCE 10-97 implementation. For general information on these

Page 640: International Design Codes

Steel Design Per ASCE 10-97 Section 14A14-4

options, refer to sections 2 and 5 of the STAAD Technical Reference Manual.

Table of Steel Design Parameters for ASCE 10-97

Parameter Name

Default Value

Description

KY 1.0 Effective length factor (K) for compression buckling about the Y-axis (minor axis)

KZ Effective length factor (K) for compression buckling about the Z-axis (major axis)

1.0

KT 1.0 Effective length coefficient for warping restraint (clause 3.14.4, pg 11)

LY Member Length

Length to calculate slenderness ratio for buckling about the Y-axis (minor axis)

LZ Member Length

Length to calculate slenderness ratio for buckling about the Z-axis (major axis)

LT Member Length

Effective length for warping.

FYLD 36.0 KSI Yield Strength of steel

NSF 1.0 Net section factor for tension members

UNL Member Length

Unsupported length of member for calculation of allowable bending stress

UNF 1.0 Same as UNL, but provided as a fraction of the member length

TRACK 0.0 0.0 = Suppresses printing of allowable stresses 1.0 = Prints all allowable stresses

DMAX 45.0 in. Maximum allowable depth for member selection

DMIN 0.0 in. Minimum allowable depth for member selection

RATIO 1.0 Permissible ratio that determines the cut off point for pass/fail status. A value below this quantity indicates PASS while a value greater than this quantity indicates FAILURE.

BEAM 1.0 0.0 = Perform design at beam ends and section locations specified according to the SECTION command 1.0 = Perform design at the ends and eleven

intermediate sections of the beam

Page 641: International Design Codes

Section 14A 14-5

Table of Steel Design Parameters for ASCE 10-97

Parameter Name

Default Value

Description

MAIN 2 Parameter that indicates the member type for the purpose of calculating the KL/R ratio (SEE CLAUSE 4.4, PAGE 25)

= 2 : COMPRESSION MEMBER KL/R <= 200

= 4 : HANGAR MEMBERS KL/R <= 375

= 10 : DO NOT PERFORM THE KL/R CHECK = 1 : LEG MEMBER KL/R <= 150

= 3 : TENSION MEMBER KL/R <= 500

(Clause 4C.4, page 43) = 5 : REDUNDANT MEMBERS KL/R <= 250

ELA 4 Indicates what type of end conditions are to be used from among Equations 4.7-4 thru 4.7-7 to determine the KL/R ratio. ELA=1 : EQN.3.7-4, Page 4

(VALID FOR LEG MEMBERS ONLY) ELA=2 : EQN.3.7-5, Page 4 ELA=3 : EQN.3.7-6, Page 4 ELA=4 : EQN.3.7-7, Page 5

ELB 1 Indicates what type of end conditions are to be used from among Equations. 4.7-8 thru 4.7-10 to determine the KL/R ratio. ELB=1 : EQN.3.7-8, Page 5, EQN.3.7-12, Page 5 ELB=2 : EQN.3.7-9, Page 5, EQN.3.7-13, Page 5 ELB=3 : EQN.3.7-10, Page 5, EQN.3.7-14,Page 5

LEG 0.0 This parameter is meant for plain angles. 0.0 = indicates that the angle is connected by both legs and allowable stress in axial tension is 1.0FYLD.

2.0 = indicates that the angle is connected by the

1.0 = indicates that the angle is connected only by the shorter leg and allowable tensile stress is computed per clause 4.10.2 as 0.9FYLD.

longer leg.

DBL 0.75 in. Diameter of bolt for calculation of number of bolts required and the net section factor.

FYB 36 KSI Yield strength of bolt.

FVB 30 KSI Shear strength of bolt.

Page 642: International Design Codes

Steel Design Per ASCE 10-97 Section 14A14-6

Table of Steel Design Parameters for ASCE 10-97

Parameter Name

Default Value

Description

NHL

0 Number of bolt holes on the cross section that should be used to determine the net section factor for tension capacity.

Notes: All values must be provided in the current unit system.

Page 643: International Design Codes

14-7

Steel Design per ASCE Manuals and Reports

Section 14B

14B.1 General Comments

This document presents some general statements regarding the implementation of the Steel Design per ASCE Manuals and Reports on Engineering Practice No. 52 – Guide for Design of Steel Transmission Towers, Second Edition. The design philosophy and procedural logistics for member selection and code checking is based upon the principles of allowable stress design. Two major failure modes are recognized: failure by overstressing and failure by stability considerations.

The following sections describe the salient features regarding the process of calculation of the relevant allowable stresses and the stability criteria being used. Members are proportioned to resist the design loads without exceeding the allowable stresses and the most economical section is selected based on the least weight criteria. The code checking part of the program also checks the slenderness requirements, the minimum metal thickness requirements and the width-thickness requirements. It is generally assumed that the user will take care of the detailing requirements like provision of stiffeners and check the local effects like flange buckling, web crippling, etc. It general, it may be noted that the concepts followed in MEMBER SELECTION and CODE CHECKING procedures are similar to that of the AISC based design. It is assumed that the user is familiar with the basic concepts of Steel Design facilities available in STAAD. Please refer to Section 3 of the STAAD Technical Reference Manual for detailed information on this topic. This document specifically addresses the implementation of steel design based on ASCE Pub. 52.

Page 644: International Design Codes

Steel Design Per ASCE Manuals and Reports Section 14B14-8

14B.2 Allowable Stresses per ASCE (Pub. 52)

The member design and code checking in the STAAD implementation of ASCE (Pub. 52) is based upon the allowable stress design method. Appropriate sections of this publication are referenced below. Allowable Axial Tensile Stress

Allowable tensile stresses are calculated on the basis of the procedure described in section 4.10. The NSF parameter (Table 1.1) may be used if the net section area needs to be used.

Allowable Axial Compressive Stress

Allowable compressive stress calculation is based on the procedures of section 4.6 through 4.9. For angle members under compression, the procedure of sections 4.7 and 4.8 have been implemented. Capacity of the section is computed for column buckling and wherever applicable, torsional buckling. The user may control the effective lengths for buckling using the LX, LY, LZ and/or KX, KY, KZ parameters (Table 1.1). Allowable Bending Compressive Stress

Calculations for allowable bending compressive stress about the major axis and minor axis are based on the procedures of section 4.14. Procedures outlined in sections 4.14.1 through 4.14.6 have been implemented. Allowable Bending Tensile Stress

Calculations for allowable bending tensile stress about the major and minor axis are based on the procedures of section 4.14.2. Allowable Shear Stress

Calculation of the allowable shear stress is based on the procedure outlined in section 4.15 of the ASCE Pub. 52. The procedure of

Page 645: International Design Codes

Section 14B 13-9

section 4.15.2 is followed for angles and the procedure of section 4.15.1 is followed for all other sections.

Critical Conditions used as criteria to determine Pass/Fail status

These are Clause 4.4 for slenderness limits, Equation 4.12-1 for Axial Compression and Bending, Equation 4.13-1 for Axial Tension and Bending, Clause 4.9.2 for Maximum w/t ratios and Clause 4.15 for Shear.

14B.3 Design Parameters

Design per ASCE (Pub. 52) must be initiated by using the command CODE ASCE. This command should be the first command after the PARAMETER statement. Other applicable parameters are summarized in Table 1.1. These parameters may be used to control the design process to suit specific modeling needs. The default parameter values have been selected such that they are frequently used numbers for conventional design.

14B.4 Code Checking and Member Selection

Both code checking and member selection options are available in the ASCE Pub. 52 implementation. For general information on these options, refer to section 3 of the STAAD Technical Reference Manual. For information on specification of these commands, refer to section 6.

Page 646: International Design Codes

Steel Design Per ASCE Manuals and Reports Section 14B14-10

14B.5 Parameter Definition Table

Table 14B.1 - Steel Design Parameters for ASCE (PUB. 52) Based Design

Parameter Name

Default Value

Description

KY 1.0 Effective length factor (K) for compression buckling about the Y-axis (minor axis)

KZ 1.0 Effective length factor (K) for compression buckling about the Z-axis (major axis)

KT 1.0 Effective length coefficient for warping restraint (clause 4.14.4, pg 36)

LY Member Length

Length to calculate slenderness ratio for buckling about the Y-axis (minor axis)

LZ Member Length

Length to calculate slenderness ratio for buckling about the Z-axis (major axis)

LT Member Length

Effective length for warping.

FYLD 36.0 KSI Yield Strength of steel

NSF 1.0 Net section factor for tension members

UNL Member Length

Unsupported length of member for calculation of allowable bending stress

UNF 1.0 Same as UNL, but provided as a fraction of the member length

TRACK 0.0 1.0 = Suppresses printing of allowable stresses 1.0 = Prints all allowable stresses

DMAX 45.0 in. Maximum allowable depth for member selection

DMIN 0.0 in. Minimum allowable depth for member selection

RATIO 1.0 Permissible ratio that determines the cut off point for pass/fail status. A value below this quantity indicates PASS while a value greater than this quantity indicates FAILURE.

BEAM 0.0 2.0 = Perform design using the section locations specified according to the SECTION command 3.0 = Perform design at the ends and eleven intermediate sections of the beam

Page 647: International Design Codes

Section 14B 13-11

Table 14B.1 - Steel Design Parameters for ASCE (PUB. 52) Based Design

Parameter Name

Default Value

Description

MAIN 2 Parameter that indicates the member type for the purpoof calculating the KL/R ratio (SEE CLAUSE 4.4, PAGE 25) = 10 : DO NOT PERFORM THE KL/R CHECK = 1 : LEG MEMBER KL/R <= 150 = 2 : COMPRESSION MEMBER KL/R <= 200 = 3 : TENSION MEMBER KL/R <= 500 = 4 : HANGAR MEMBERS KL/R <= 375 (Clause 4C.4, page 43) = 5 : REDUNDANT MEMBERS KL/R <= 250

ELA 4 Indicates what type of end conditions are to be used From among Equations 4.7-4 thru 4.7-7 to determine ththe KL/R ratio. ELA=1 : EQN.4.7-4, Page 26

(VALID FOR LEG MEMBERS ONLY) ELA=2 : EQN.4.7-5, Page 27 ELA=3 : EQN.4.7-6, Page 27 ELA=4 : EQN.4.7-7, Page 27

ELB 1 Indicates what type of end conditions are to be used From among Equations. 4.7-8 thru 4.7-10 to determine the KL/R ratio. ELB=1 : EQN.4.7-8, Page 27, EQN.4.7-12, Page 28 ELB=2 : EQN.4.7-9, Page 27, EQN.4.7-13, Page 28 ELB=3 : EQN.4.7-10, Page 27, EQN.4.7-14,Page28

LEG 0.0 This parameter is meant for plain angles. 3.0 = indicates that the angle is connected by both legs and allowable stress in axial tension is 1.0FYLD. 4.0 = indicates that the angle is connected only by the shorter leg and allowable tensile stress is computed per clause 4.10.2 as 0.9FYLD. 5.0 = indicates that the angle is connected by the longer leg.

DBL 0.75 in. Diameter of bolt for calculation of number of bolts required and the net section factor.

FYB 36 KSI Yield strength of bolt.

FVB 30 KSI Shear strength of bolt.

Page 648: International Design Codes

Steel Design Per ASCE Manuals and Reports Section 14B14-12

Table 14B.1 - Steel Design Parameters for ASCE (PUB. 52) Based Design

Parameter Name

Default Value

Description

NHL

0 Number of bolt holes on the cross section that should be used to determine the net section factor for tension capacity.

Notes:

All values must be provided in the current unit system.

Page 649: International Design Codes

Section 15 American Steel Design

Per A.P.I. Code

Page 650: International Design Codes
Page 651: International Design Codes

15-1

Steel Design Per A.P.I.

Section 15

15.1 Design Operations

STAAD contains a broad set of facilities for the design of structural members as individual components of an analyzed structure. The member design facilities provide the user with the ability to carry out a number of different design operations. These facilities may be used selectively in accordance with the requirements of the design problem. The operations to perform a design are: • Specify the members and the load cases to be considered in the

design; • Specify whether to perform code checking or member

selection; • Specify design parameter values, if different from the default

values; and • Specify design parameters to carry out punching shear checks.

These operations may be repeated by the user any number of times depending upon the design requirements, but care should be taken when coupled with manipulation of the punching shear LEG parameter. The basic process is:-

a. Define the STAAD model geometry, loading and analysis.

b. Define the API code parameters with LEG 1.0.

c. Run the analysis and API design which creates the Geometry file and give preliminary design results.

d. Check and modify the Geometry file as necessary.

Page 652: International Design Codes

Steel Design Per A.P.I.

Section 15 15-2 e. Reset the LEG parameter to 2.0 and re-run the analysis to read

the modified Geometry file for the final design results.

15.2 Allowables per API Code

For steel design, STAAD compares the actual stresses with the allowable stresses as defined by the American Petroleum Institute (API-RP2A) Code. The 20th edition of API Code, as published in 1993, is used as the basis of this design (except for tension stress).

15.2.1 Tension Stress

Allowable tension stresses, as calculated in STAAD, are based on the API Code, clause (3.2.1-1). Allowable tension stress on the net section

Ft = 0.60Fy

15.2.2 Shear Stress

Beam Shear Stress

Allowable beam shear stress on the gross section must conform to (3.2.4-2):

Fv = 0.4 Fy

fv = V / 0.5 A (3.2.4-1)

The maximum applied beam shear stress is:

Torsional Shear Stress

Allowable torsional shear stress

Fvt = 0.4 Fy (3.2.4-4)

Page 653: International Design Codes

Section 15 15-3

Fvt is the maximum torsional shear stress per (3.2.4-3).

15.3 Stress due to Compression

The allowable compressive stress on the gross section of axially loaded compression members is calculated based on the formula 3.2.2-1 in the API Code, when the largest effective slenderness

ratio ⎟⎠⎞

⎜⎝⎛

rKl

is less than Cc =yF

E22π . If r

Kl exceeds Cc the

allowable compressive stress is increased as per formula (3.2.2-2) of the Code.

For tD

> 60 the lesser of Fxe or Fxc are substituted for Fxy .

Fxe = the elastic local buckling stress calculated with C, the critical elastic buckling coefficient = 0.3 (3.2.2-3)

cal buckling stress, (3.2.2-4)

15.4 Bending Stress

The allowable bending stress for tension and compression for a symmetrical member loaded in the plane of its minor axis, as given in Section 3.2.3 is:

a) Fb = 0.75 Fy

provided

Fxc = the inelastic lo

tD

≤ yF

1500 (Imperial Units)

b) b = F ⎥⎦

⎤⎢⎣

⎡−

EtDFy74.184.0 Fy

Page 654: International Design Codes

Steel Design Per A.P.I.

Section 15 15-4

yF1500

< tD

< yF

3000where (Imperial Units)

c) Fb = ⎥⎤

⎢DFy58072. F⎦⎣

⎡−

Et.0

y

where yF

3000 <

tD

≤ 300 (Imperial Units)

15.5 Combined Compression and Bending

Members subjected to both axial compression and bending stresses are proportioned to satisfy API formula 3.3.1-1 and 3.3.1-2 when

a

a

Ff

is greater than 0.15, otherwise formula 3.3.1-3 applies. It

g code checking or member selection, if should be noted that durin

aF3.3.1-1/2.

ign Parameters

af exceeds unity, the program does not compute the second

15.6 Des

The program contains a large number of parameter names which are required to perform design and code checks. These parameter names, with their default values, are listed in Table 12.1. These parameters communicate design decisions from the engineer to the program. (Also see section 5.44.1). The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements for an analysis, some or all of these parameter values may have to be changed to exactly model the physical structure. For example, by default the KZ value (k value in local z-axis) of a member is set to 1.0, wile in the real

Page 655: International Design Codes

Section 15 15-5

structure it may be 1.5. In that case, the KZ value in the program can be changed to 1.5, as shown in the input instruction (Section

). Similarly, the TRACK value of a member is set to 0.0, which means no allowable stresses of the member will be printed. If the allowable stresses are to be printed, the TRACK value must be set

1.0. Note: The parameter names DMAX and DMIN are only used for member selection.

T e 15.1- Americ API) S

5

to

abl an ( teel Design Parameters

Parameter Name

Default Value

Description

KY 1.0 K value in local y-axis.

Usually, this is minor axis.

KZ 1.0 K value in local z-axis.

Usually, this is major axis.

LY Member Length

calculate slenderness ratio. Length in local Y-axis to

LZ M r Length

rness ratio. embe Length in local Z-axis to calculate slende

FYLD 36 KSI Yield strength of steel.

NSF 1.0 Net section factor for tension members.

UNL M r Length

ble bending embe Unsupported length for calculating allowastress

UNF 1.0 Same as above provided as a fraction of actual member length

CB 1.0 Cb value as used in Section 1.5 of AISC ated

lue to be used in gn

0.0 = Cb value to be calculAny other value will mean the vadesi

MAIN 0.0 1.0 = Main member

2.0 = Secondary member

SSY 0.0 = Sidesway in local y-axis

.0 = No sidesway

0.0

1

Page 656: International Design Codes

Steel Design Per A.P.I.

Section 15 15-6

Table 15.1- American (API) Steel Design Parameters

Parameter Name

Default Value

Description

SSZ Same as above except in local z-axis 0.0

CMY Cm value in local y & z axes

CMZ

0.85 for sidesway*

and calculated for no sidesway

TRACK 0.0 1.0 = Print all critical member stresses

ks except punching shear

100.0 = Suppress all chec

DMAX 0.0 Maximum allowable depth

DMIN 0.0 Minimum allowable depth

RATIO Perm sses issible ratio of the actual to allowable stre

WELD 1 for closed sections

2 for open sections

1 = g is one side only except for wide flange lways

2 = W

s

Weld type, as explained in section 3.1.1.

Weldinor tee sections, where the web is aassumed to be welded on both sides.

lding is bothe sides. For closed sections like pipe or tube, the welding will be only on one ide.

BEAM 1.0 0.0 = design only fothose at loca

r end moments or tions specified by the SECTION

command. at twelfth points along the

beam, and use the maximum Mz location for = calculate moments

design. WMIN 1.16 in. Minimum thickness

WSTR 0.4 X FLYD Allowable welding stress

LEG 1.0

2.0

To write out external parameters file.

To read in the external parameters file.

Page 657: International Design Codes

Section 15 15-7

15.7 Code Checking

The purpose of code checking is to ascertain whether the provided section properties of the members are adequate as per API. Code checking is done using the forces and moments at specific sections of the members. If no sections are specified, the program uses the start and end forces for code checking. When code checking is selected, the program calculates and prints whether the members have passed or failed the checks, the critical condition of API code (like any of the API specifications for compression, tension, shear, etc.), the value of the ratio of the critical condition (overstressed for value more than 1.0 or any other specified RATIO value), the governing load case, and the location (distance from the start of the number of forces in the member) where the critical condition occurs. Code checking can be done with any type of steel section listed in Section 2.2, American Steel Design, of the Technical Reference manual.

15.8 Member Selection

STAAD is capable of performing design operations on specified members. Once an analysis has been performed, the program can select the most economical section, i.e. the lightest section which fulfills the code requirements for the specified member. The section selected will be of the same type section as originally designated for the member being designed. Member selection can also be constrained by the parameters DMAX and DMIN which limits the maximum and minimum depth of the members. Member selection can be performed with all types of hollow steel sections.

Page 658: International Design Codes

Steel Design Per A.P.I.

Section 15 15-8 Selection of members whose properties are originally input from a user created table will be limited to sections in the user table. Member selection cannot be performed on members whose section properties are input as prismatic.

15.9 Truss Members

As mentioned earlier, a truss member is capable of carrying only axial force. So in design, no time is wasted calculating the allowable bending or shear stresses, thus reducing design time considerably. Therefore, if there is any truss member in an analysis (like bracing or strut, etc.), it is wise to declare it as a truss member rather than as a regular frame member with both ends pinned.

15.10 Punching Shear

For tubular members, punching shear may be checked in accordance with the American Petroleum Institute (API) RP 2A – 20th Edition Section 4. The parameter PUNCH is used to identify joint types for each end of the member where the punching shear check is required. The PUNCH parameter is only read in from the external geometry file. The external geometry file is described in section 12.13. The PUNCH parameter is not specified within the STAAD input file (the file with the .std extension).

Type of Joint and Geometry Req. Value of Parameter PUNCH

K (overlap) 1.0 K (gap) 2.0 T & Y 3.0 CROSS 4.0 CROSS (with/diaphragms) 5.0

Page 659: International Design Codes

Section 15 15-9

Note: A value representing joint type and geometry must be provided for parameter PUNCH, in the external file. On the first run where no external table is present, LEG must equal 1.0.

15.11 Generation of the Geometry File

Automatic selection of the chord and brace members are performed with the parameter LEG 1.0.

Two tubular members are used by the program to identify the chord member. The chord members must be collinear (5 degree tolerance). The chord member must have a greater diameter and thickness than the brace member being considered. The punching shear check is performed on the joint treating it as a T/Y joint. The yield stress of the brace is used. In the 50% strength check the brace and chord yield are assumed to be the same.

The major moment axis Mz is taken as In Plane Bending (IPB). To change this, the parameter SWAP 1 should be used in the external geometry file. Note: The in-plane/out-of-plane correspondence can be set by using the BETA angle. If the punching shear cannot be performed at the joint for the member being considered, a message is written to the output file <filename>.ANL. If a punching shear check is performed with the parameter LEG 1.0 used, then the geometry data used to perform the check is written to the default external output file APIPUN. The default external output/input file name can be changed by using the command line:-

Page 660: International Design Codes

Steel Design Per A.P.I.

Section 15 15-10 CODE API <filename>.

The yield strength of the brace is used in the punching shear check. This can be changed in the external geometry file. The user should ensure that the correct cord member has been selected for the check.

15.12 Chord Selection and Qf Parameter

Qf is a factor to account for the presence of nominal longitudinal stress in the chord. When calculating Qf for the joints, the moments used in the chord stress calculation will be from the computer node results and not the representative moments underneath the brace. If the moment varies significantly along the chord, it is more accurate to use the actual chord moment in the middle of the brace foot print. The tests reported in Reference I1 were performed with a constant moment along the chord. Thus for a local joint check, the local chord moment (under the brace) should be used. STAAD calculates Qf based on the moment at the chord member. The chord member can be selected automatically by initial screening by the program (based on geometry and independent of loading) or specified by the user in the External file.

This external output data file can be edited and used as an external input file to re-perform the check using the parameter PUNCH 1.0 to 5.0. This external input file allows can/stub geometry data to be specified and chords to be assigned geometry where they could not be identified in the Automatic selection. The parameter LEG 2.0 must be used to read an external input file where the default name is APIPUN.

1 Ref I: Boone, TJ, Yura, JA and Hoadley, PW, Ultimate Strength if Tubular Joints – Chord Stress Effects, OTC 4828, 1984

Page 661: International Design Codes

Section 15 15-11

In the automatic selection of the chord two collinear members (5 degree tolerance) are used to identify the chord. The chord is then selected from one of the two members based on the larger diameter then thickness or then by the minimum framing angle; for T joints the first member modeled will be selected as the chord. The user should confirm that the chord either be assigned by the program or the user is representative of the local chord moment for the brace in question.

15.13 External Geometry File

An example of the external geometry file is shown below:

BRACE CHORD PUNCH D T d T GAP FYLD THETAT TW SWAP

209 211 3

3 12.752 0.00

17.992 0.984 12.752 0.787 0.000 50.00 0.00 0.000 0

209 210 3 17.992 0.984 12.752 0.787 0.000 50.00 0.00 0.000 0

212 202 17.992 0.787 0.787 0.000 50.00 0.000 0

The parameters used in the external file are defined as follows: Table 15.2 – External File

Parameter Description

PUNCH Parameter for punching shear (See Section 12.10)

BRACE Member number of brace CHORD Member number of chord D Chord Diameter in inches T Chord Thickness in inches d Brace Diameter in inches T Brace Thickness in inches GAP Gap in inches (must be negative for overlap

K-joint) FYLD Local yield strength used for joint in KIPS THETAT Angle of through brace in overlap K-joint in

Page 662: International Design Codes

Steel Design Per A.P.I.

Section 15 15-12 Table 15.2 – External File

Parameter Description

Degrees TW Used in overlap K-joint, taken as the lesser of

the weld throat thickness or thickness t of the thinner brace in inches

SWAP If parameter SWAP 0 is used then major moment Mz is taken for In Plane Bending (IPB). SWAP 1 uses the minor moment My as the IPB.

Notes: • For overlap K-joints, the through brace is assumed to be the

same diameter as the brace being checked. • If any of the parameters for diameter and thickness specified

in the external file are less than that for members being checked, then the member properties specified in the STAAD file shall be used.

• The member diameter and thickness should be used in API equation (4.1-1); in this check it has been assumed that the yield strength of the chord and brace members are the same.

• The geometry file name is currently limited to eight characters (4 if an extension as .txt is used).

The overall process of performing punching shear checks consists of two steps. These steps are explained in section 12.16.

15.14 Limitations

The parameter SELECT 1.0 should not be used while carrying out punching shear checks. It can be used in initial runs for member selection. No classification of the joint is performed using the loading. No hydrostatic checks are performed.

Page 663: International Design Codes

Section 15 15-13

15.15 Tabulated Results of Steel Design

For code checking or member selection, the program produces the results in a tabulated fashion. The items in the output table are explained as follows:

a) Member refers to the member number for which the design is performed.

b) TABLE refers to AISC steel section name which has been checked against the steel code or has been selected.

c) RESULTS prints whether the member has PASSed or FAILed. If the RESULT is FAIL, there will be an asterisk (*) mark on front of the member.

d) CRITICAL COND refers to the section of the AISC code which governs the design.

e) RATIO prints the ratio of the actual stresses to allowable stresses for the critical condition. Normally a value of 1.0 or less will mean the member has passed.

f) LOADING provides the load case number which governed the design.

g) FX, MY, and MZ provide the axial force, moment in local Y-axis, and the moment in local Z-axis respectively. Although STAAD does consider all the member forces and moments (except torsion) to perform design, only FX, MY and MZ are printed since they are the ones which are of interest, in most cases.

h) LOCATION specifies the actual distance from the start of the member to the section where design forces govern.

i) If the parameter TRACK is set to 1.0, the program will block out part of the table and will print the allowable bending stressed in compression (FCY & FCZ) and tension (FTY & FTZ), allowable axial stress in compression (FA), and allowable shear stress (FV).

Page 664: International Design Codes

Steel Design Per A.P.I.

Section 15 15-14

15.16 The Two-Step Process

The overall procedure for performing the code check per the API code is as follows: Step 1 – Creating the geometry data file. This is done by specifying the name of the geometry data file alongside the command line CODE API. If a file name is not specified, STAAD automatically assigns the file name APIPUN to the geometry data file. The parameter instructions in the .std file should contain the LEG parameter and it should be assigned the value 1.0.

Example Reading External Geometry File UNIT INCHES KIPS PARAMETERS * All joint data will be written to external file GEOM1 for punching shear. CODE API GEOM1 LEG 1.0 * Joints to be considered as T and Y, i.e. PUNCH is set to 3.0. FYLD 50.0 ALL TRACK 1.0 ALL RATIO 1.0 ALL BEAM 1.0 ALL CHECK CODE ALL

After ensuring that your STAAD input file contains the above data, run the analysis. Once the analysis is completed, you will find that a file by the name GEOM1 has been created and is located in the same folder as the one where your .std file is located. (In case you did not specify a file name - GEOM1 shown in the earlier example - STAAD will create the file named APIPUN.

Page 665: International Design Codes

Section 15 15-15

Step 2 – The geometry data file (GEOM 1 or otherwise) should be inspected and modified as required such as changing the PUNCH values and local section properties for the punching shear checks. Modify the .std file so it reruns the code check process by reading the instructions of the GEOM file. This message is conveyed by changing the value of the LEG parameter to 2.0. After making this change, a re-analysis will result in the program using the information in the geometry data file (GEOM1, APIPUN, or otherwise) for performing the code check.

Example Reading an existing Joint Geometry Data File, GEOM1 UNIT INCHES KIPS PARAMETERS * All joint data will be read from the external file GEOM1 for punching shear. CODE API GEOM1 LEG 2.0 FYLD 50.0 ALL TRACK 1.0 ALL RATIO 1.0 ALL BEAM 1.0 ALL CHECK CODE ALL

Page 666: International Design Codes

Steel Design Per A.P.I.

Section 15 15-16